WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used...

20
LINEAR GRILLES & REGISTERS WE SHAPE AIR PRODUCTS CATALOGUE PRODUCT BULLETIN

Transcript of WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used...

Page 1: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

LINEAR GRILLES & REGISTERS

WE SHAPE

AIR

PRODUCTS CATALOGUE

PRODUCT BULLETIN

Page 2: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

Dubai Head Office:

Tel: +971 4 706 97777Fax: +971 4 706 9787

Abu Dhabi Branch:

Tel: +971 2 645 0107Fax: +971 2 645 0167

Email: [email protected]

P.O. Box 50708, DubaiUnited Arab Emirates

w w w . b e t a g . c o m

Page 3: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

SINGLE DEFLECTION LINEAR GRILLES & REGISTERS 1-2

DOUBLE DEFLECTION LINEAR GRILLES & REGISTERS

ACCESSORIES

ALUMINUM FLOOR GRILLES-IMP KLIMA

PERFORMANCE DATA

3-4

5-6

7-10

11-17

Page 4: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in

cooling, heating or air ventilation application.

The single deflection linear grille is composed of a set of fixed horizontal straight bars attached to a

frame, both are manufactured from extruded aluminium sections.

* 12 MM OPTIONAL

27 mm

65 mm

30 mm*16 mmB + 50 mm

B - 5 mm

5.4mm

27 mm

30 mm*16 mmB + 50 mm

5.4mm

B - 10 mm

TYPE: RLR

TYPE: RLG

LINEAR GRILLES & REGISTERS

SINGLE DEFLECTION LINEAR GRILLES & REGISTERS

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Page 5: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

>> Front bars have one of the following basic designs:

O- O deflection bars ( Standard)

O- 15 deflection, two way

>> Front bars are assembled in horizontal straight lines With a center to

center spacing of 16 mm & 12 mm.

>> Available with easily removeable opposed blades damper attached to

the frame by means of (S) clips to ensure tight attachment and maximum

flexibility. The damper Is made of extruded aluminium bars and opening of

the damper is easily adjusted by means of control Iever that is driven by

O- 15 deflection, one way

a screw driver from the front face of the register.

Available type of finishings :

Natural anodized aluminium finish.

powder coated to RAL codes.

OO deflection ( Standard) O15 DEFLECTION, ONE WAY O15 DEFLECTION, 2 WAY

RLG RLR

A

B

A

B

TYPES & MODELS

FIXING

ORDERING SYSTEM

RLR

RLG

: Single deflection linear grille with damper black/ mill finish

: Single deflection linear grille without damper.

SIZE : Width x Height

CURVE : If curved required

RAL

Anodized

: Powder coated finish as per RAL codes.

: Anodized aluminium finish.

Example: RLR 1000x150 Anodized

TYPE

SIZE

CURVE

FINISH

LINEAR GRILLES & REGISTERS

SINGLE DEFLECTION LINEAR GRILLES & REGISTERS

Page 6: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

The double deflection linear gille is a wall mounted gille, used as an exhaust or retun grille in

cooling, heating or air ventilation application.

The double deflection linear grille is composed of a set of fixed horizontal straight bars in the front

face and individually adjustable vertical deflection on the rear to control air flow pattern, both are

manufatured from extruded aluminum sections.

* 12 MM OPTIONAL

83 mm

30 mm*16 mmB + 50 mm

B - 5 mm

5.4mm

45 mm

30 mm*16 mmB + 50 mm

5.4mm

B - 10 mm

TYPE: SLR

TYPE: SLG

LINEAR GRILLES & REGISTERS

DOUBLE DEFLECTION LINEAR GRILLES & REGISTERS

Page 7: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICEALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

>> Front bars have one of the following basic designs:

O- O deflection bars ( Standard)

O- 15 deflection, two way

>> Front bars are assembled in horizontal straight lines With a center to

center spacing of 16 mm & 12 mm.

>> Available with easily removeable opposed blades damper attached to

the frame by means of (S) clips to ensure tight attachment and maximum

flexibility. The damper Is made of extruded aluminium bars and opening of

the damper is easily adjusted by means of control Iever that is driven by

O- 15 deflection, one way

a screw driver from the front face of the register.

Available type of finishings :

Natural anodized aluminium finish.

powder coated to RAL codes.

OO deflection ( Standard) O15 DEFLECTION, ONE WAY O15 DEFLECTION, 2 WAY

SLG SLR

A

B

A

B

TYPES & MODELS

FIXING

ORDERING SYSTEM

SLR

SLG

: Double deflection linear grille with damper black/ mill finish

: deflection linear grille without damper.Double

SIZE : Width x Height

CURVE : If curved required

RAL

Anodized

: Powder coated finish as per RAL codes.

: Anodized aluminium finish.Example: SLR 2000x250 RAL 9016

TYPE

SIZE

CURVE

FINISH

LINEAR GRILLES & REGISTERS

DOUBLE DEFLECTION LINEAR GRILLES & REGISTERS

Page 8: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

1- ONE END LINEAR GRILLE/REGISTER (D 1)

AVAILABLE IN ANY STANDARD SIZE.

2- INTERMEDIATE LINEAR GRILLE/REGISTER (D2)

AVAILABLE IN ANY STANDARD SIZE.

3- CORNER PIECES (D3,D4,DS)

AVAILABLE IN ANY COMBINATION OF B, X. Y &

100

150

200

250

300

300

600

800

1000

1200

300

600

800

1000

1200

O45O90O135

B (mm) x (mm) Y (mm) (degree)

D1

D2

X

Y

BD3

X Y

B

D5

X Y

D4

B

LINEAR GRILLES & REGISTERS

ACCESSORIES

Page 9: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

4- CURVED SHAPE LINEAR GRILLES (D6)

Minimum radius = 1000 mm

Used as Supply/Return linear grille

LINEAR GRILLES & REGISTERS

ACCESSORIES

D6

Mn

mum

radi

us :

1 m

ii

Page 10: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Application

Floor fixed bar aluminum grilles AR-8, AR-9 are used for air supply and exhaust in all kinds of low pressure air

handling.

Description Floor fixed bar aluminum grilles AR-8, AR-9 are made of cold-worked sectional aluminum, galvanized in natural

aluminum colour, fixed vertical vanes are designed so as to achieve the horizontal air injection at AR-8 and in theO15 angle air injection at AR-9. Both are intended for floor installation. The attached accessory devices for air flow

rate and direction control are made of black varnished pickled sheet.

AR-8, AR-9

The supply and exhaust air grilles AR-8, AR-9 consist of supporting frames and vertical fixed bars.

54

AR-9H/B

12,5

H/BAR-8

12,5

ALUMINUM FLOOR GRILLES

Page 11: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

1. Chart of air pressure drop and sound level-straight adjusted vanes

Symbols:

total air pressure drop

estimated sound power level according to NR- curves

estimated sound power level according to dB (A)

(Pa)PcelL

NNRL

NA

Table for sound data correction factor

0.005 0.01 0.02 0.05 0.1 0.2 0.4

+6+3 0-3-7-10-13

The chart is valid for the exhaust air grilles AR-8 and AR-9 with

accessory device.

2. Chart for detemination of effective intake velocity.

LNA LNNR

Correction

2F (m )ef

3Q = 1000 m /h

2F = 0.05 m (from table 4)ef

V = 5.3 m/sef

Result:Example :

Effective intake air velocity vef [m/s]

Dam

pin

g a

dju

stm

en

t

open25%

50%

100%

1 2 3 4 5 6 103

4

5

10

20

30

40

50

10

25

30

35

40

54

45

50

40

53

30

25 L NA

]

[dB(A

)

3Intake air flow Q [m /h]

30 50 100 200 500 1000 2000 5000 10000 20000

10

8

7

6

5

4

3

2

1,5

000

5, 0

1,0 0,02

0,03

04

,0

50,

0

0,1

0,2

0,3

04, 0,5

Effective discharge area Fef [m]

Effe

ctive

in

take

ve

locity V

ef [m

/s]

ALUMINUM FLOOR GRILLES

L NAR

Vef

pcef

L NAR

Page 12: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

225325425525625825

10251225

x 75 0.0040.0060.0090.0110.0130.0170.0210.026

225325425525625825

10251225

x 125 0.0090.0130.0170.0210.0260.0330.0410.049

325425525625825

10251225

x 225 0.0260.0330.0410.0490.0660.0820.090

425525625825

10251225

x 325 0.0490.0600.0720.0950.1200.140

0.0950.1220.1550.185

625825

10251225

x 425

10251225

x 525

B x Hmm

Effective intakeArea F (m2)efAR-8, AR-9

The intake air flow is determined by measuring the intake air velocity

at parallel set-up bars. The intake air flow can be calculated as

follows:

Q = V x F x 3600ef ef

3Q = (m /h)

V (m/s)ef

2F (m )ef

The right for technical alterations reserved!

4 Table for effective intake areas

3. Room sound attenuation chart

3V’ (m ) calculate volume depending on room reverberation 3V (m ) real volume of the room

For the grilles the following values are required:

1. Normal rooms V’ = V

2. Rooms with explicitly reverberating walls V’ = 0.5V

3. Rooms with absorption walls V’ = 2V

ALUMINUM FLOOR GRILLES

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0,7 1,0 2,0 3,0 4,0 5,0

Distance from sound source [m]

Ro

om

atten

ua

tio

n [d

B(A

)]

2000

1000

500

200

100

50

20

3

Volu

e ’ [

]

mV

m

Page 13: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

The a

pplic

atio

n o

f heavy

prin

ted d

imensio

ns

recom

ended.

The rig

ht fo

r technic

al c

han

ges re

serv

ed

.

Th

row

L [m

]

4

5

6

7

8

9 1

0

15

20

Te

mp

era

ture

qu

otie

nt

0,0

50

,04

0,0

3

tttz

Effe

ctiv

e d

isch

arg

e v

elo

city

v[m

/s]

ef

42

53

25

22

51

25

75

22

5

He

igh

t H [m

m]

12

25

10

25

12

25

10

25

82

5

62

58

25

12

25

62

58

25

12

25

62

5

10

25

82

5

52

5

42

5

52

5

42

5

32

56

25

52

5

42

5

12

25

10

25

82

5

62

5

52

5

42

5

32

5

22

5

32

5

40

00

30

00

2000

15

00

10

00

80

0

6005

00

40

0

300

20

015

0

10

9

8

7

6

5

43

21,5

1

Width B [mm]C

ha

rt for d

ete

rmin

atio

n o

f no

min

al s

ize

s, in

du

ctio

n a

nd

air

stre

am

tem

pre

ture

for a

lum

iniu

m g

rilles A

R-8

, AR

-9

Va

lid fo

r: B/H

12

Ind

uctio

n i

54

10

15

20

304

0

Occupied zone

b02

0,8 m

V[m

/s]

LtL [

OC]

VL

= 0

,2 m

/s

3Q

[m/h

]

t2 [

OC]

A 0,2L

0,7

50,5

0,4

0,3

0,2

1,0

1,5

1,00

,9

0,8

0,7

0,6

20

19

109876543

Throw L [m]

d

e

Sprea of air str

am b

0.2[m]

Te

rmin

al v

elo

city

VL [m

/s]

3D

isc

ha

rge

air flo

w Q

[m/h

]

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

ALUMINUM FLOOR GRILLES

Page 14: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

The following tables include the results of tests conducted on three single deflection linear grilles. The

test results include Noise Criteria (NC). Static pressure versus air flow, throw and Ak. The grilles were

selected and supplied by Beta In August 1994. The Extrapolations and interpolations were made to Cover

a range of sizes and parameters according to the ETL testing laboratories Inc. who conducted the tests.

The linear grilles Were tested in accordance with the Air Diffusion Council test code for

grilles registers and diffusers No. ADC 1062: GRD-84. The grilles were tested in the ETL

testing laboratories.2The 470m reverberation room was used to conduct the tests. Quiet test air was provided' by a variable

volume air supply. Air volume was measured by the use of calibrated Orifice metering station while the

static pressure was measured employing a Dwyer Model 166-12,1/8’ diameter standard pitot tube and

read on a dwyer manometer Model 424-5.

Acoustical data was obtained Employing a Bruel and Kjaer digital frequency analyzer type 2131 and

analyzed on a computer. The reference sound source for this test was a calibrate ILG Fan Serial No. 17-

05-066A. The Octave band sound power levels were plotted on a graph of noise criteria curves which

is in the ADC test! codes.

Products Testing

Test Method

NOTES:

LINEAR GRILLES & REGISTERS

PERFORMANCE DATA

Page 15: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

WIDTH CFM per foot Vn Pt NC

90

120

150

180

210

240

270

210

240

270

300

330

360

405

240

270

300

360

405

420

450

210

240

270

300

330

405

450

270

360

450

540

630

720

810

420

480

540

600

660

720

810

360

405

450

540

608

630

675

252

288

324

360

396

486

540

16

19

20

23

26

30

35

18

23

28

32

34

37

40

19

23

27

33

37

41

45

15

18

22

25

29

36

39

0.024

0.032

0.040

0.050

0.065

0.085

0.107

0.041

0.054

0.067

0.082

0.096

0.121

0.146

0.023

0.027

0.032

0.047

0.057

0.067

0.077

0.006

0.008

0.010

0.012

0.014

0.022

0.027

4 Inch (12mm

space) An=0.333

sq.ft. Ak=0.243

sq.ft.

6 Inch (12mm

space) An=0.500

sq.ft. Ak=0.342

sq.ft.

8 Inch (12mm

space) An=0.667

sq.ft. Ak=0.478

sq.ft.

10 Inch (12mm

space) An=0.834

sq.ft. Ak=0.657

sq.ft.

CFM : Air volume in cubic feet per minute.

Ak : Effective Face Area in feet square per feet length

An : Neck Area in feet square per feet length

Vn : Neck Velocity in feet per minute

Pt : Total Preasure in inches water gauge

Th : Throw in feet

N.C. : Noise criteria

* Supply 0* Vertical blades deflection: 0 deflection

* Noise Criteria values are based on (10 dB) room attenuation

* Throw figures are measured for Linear Grilles fixed at 6” from the ceiling

* Damper is fully open

* Data is based on 1ft length

SYMBOLS

CONDITIONS

CORRECTIONS ON NOISE CRITERIA FOR OTHER LENGTHS

Length 3ft 6ft 10ft

(+9)(+7)(+4)N.C.

O O12mm Spacing - 0 DEFLECTION - VERTICAL BLADES AT 0

*IMPERIAL UNITS

THROW

SLR, SLG, RLR, RLGPERFORMANCE DATA - SUPPLY

Air Terminal Velocity (FPM) vs. Throw (Ft)O4” Height - 12mm Spacing - 0

350

300

250

200

150

100

50

0

6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM

700 CFM

500 CFM

300 CFM

Air Terminal Velocity (FPM) vs. Throw (Ft)O6” Height - 12mm Spacing - 0

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM

300

250

200

150

100

50

0

700 CFM

500 CFM

300 CFM

6”

2’6

4’6

6’6

8’6

10

’6”

12

’6”

14

’6”

16

’6”

18

’6”

20

’6”

22

’6”

24

’6”

Air Terminal Velocity (FPM) vs. Throw (Ft)O

8” Height - 12mm Spacing - 0

300

250

200

150

100

50

0

6”

2’6

4’6

6’6

8’6

10

’6”

12

’6”

14

’6”

16

’6”

18

’6”

20

’6”

22

’6”

24

’6”

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM

850 CFM

700 CFM

500 CFM

1100 CFM

900 CFM

700 CFM

6”

2’6

4’6

6’6

8’6

10

’6”

12

’6”

14

’6”

16

’6”

18

’6”

20

’6”

22

’6”

24

’6”

300

250

200

150

100

50

0

Throw, Ft

Air Terminal Velocity (FPM) vs. Throw (Ft)O10” Height - 12mm Spacing - 0

Air

Te

rmin

al V

elo

cit

y, F

PM

LINEAR GRILLES & REGISTERS

PERFORMANCE DATA

12

Page 16: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

WIDTH CFM per foot Vn Pt NC

90

120

150

180

210

240

270

135

180

210

240

270

300

330

210

240

270

300

330

360

405

210

240

270

300

330

360

405

270

360

450

540

630

720

810

270

360

420

480

540

600

660

315

360

405

450

495

540

608

252

288

324

360

396

432

486

0.001

0.004

0.043

0.082

0.121

0.160

0.194

0.029

0.058

0.071

0.094

0.117

0.142

0.167

0.021

0.028

0.040

0.047

0.060

0.072

0.092

0.009

0.015

0.016

0.023

0.024

0.031

0.039

15

16

20

24

30

36

39

15

20

24

29

33

36

39

18

22

27

31

33

36

40

15

20

23

27

31

34

37

4 Inch (12mm

space) An=0.333

sq.ft. Ak=0.202

sq.ft.

6 Inch (12mm

space) An=0.500

sq.ft. Ak=0.283

sq.ft.

8 Inch (12mm

space) An=0.667

sq.ft. Ak=0.396

sq.ft.

10 Inch (12mm

space) An=0.834

sq.ft. Ak=0.548

sq.ft.

SLR, SLG, RLR, RLGPERFORMANCE DATA - SUPPLY

O O12mm Spacing - 0 DEFLECTION - VERTICAL BLADES AT 45

*IMPERIAL UNITSTHROW

350

300

250

200

150

100

50

0

6” 2’6”

Air

Te

rmin

al V

elo

cit

y, F

PM

Air Terminal Velocity (FPM) vs. Throw (Ft)O4” Height - 12mm Spacing - 45

4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”

Throw, Ft

700 CFM

500 CFM

300 CFM

CFM : Air volume in cubic feet per minute.

Ak : Effective Face Area in feet square per feet length

AN : Neck Area in feet square per feet length

Vn : Neck Velocity in feet per minute

Pt : Total Preasure in inches water gauge

Th : Throw in feet

N.C. : Noise criteria

* SupplyO

* Vertical blades deflection: 45 deflection

* Noise Criteria values are based on (10 dB) room attenuation

* Throw Figures are measured for Linear Grilles fixed at 6” from the Ceiling

* Damper is fully open

* Data is based on 1ft length

CORRECTIONS ON NOISE CRITERIA FOR OTHER LENGTHS

10ft

(+9)

SYMBOLS

CONDITIONS

Length 3ft 6ft

(+7)(+4)N.C.

Air

Term

ina

l V

elo

cit

y, F

PM

400

350

300

250

200

150

100

50

0

6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”Throw, Ft

Air Terminal Velocity (FPM) vs. Throw (Ft)O6” Height - 12mm Spacing - 45

700 CFM

500 CFM

300 CFM

Air Terminal Velocity (FPM) vs. Throw (Ft)O

8” Height - 12mm Spacing - 45

850 CFM

700 CFM

500 CFM

300

250

200

150

100

50

0

6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”

Throw, Ft

Air Terminal Velocity (FPM) vs. Throw (Ft)O

10” Height - 12mm Spacing - 45250

200

150

100

50

0

Air

Te

rmin

al V

elo

cit

y, F

PM

Air

Te

rmin

al V

elo

cit

y, F

PM

6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”Throw, Ft

1100 CFM

900 CFM

700 CFM

LINEAR GRILLES & REGISTERS

PERFORMANCE DATA

Page 17: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

90

120

150

180

210

240

270

135

180

210

240

270

300

330

210

240

270

300

330

360

405

240

250

270

330

390

450

480

0.001

0.027

0.053

0.079

0.105

0.150

0.180

0.030

0.050

0.065

0.090

0.110

0.135

0.160

0.025

0.030

0.040

0.050

0.060

0.070

0.090

0.025

0.025

0.030

0.035

0.055

0.075

0.085

15

20

24

29

33

33

33

19

20

24

29

33

37

41

15

25

33

35

35

44

42

15

22

28

29

35

42

46

4 inch

6 inch

8 inch

WIDTH CFM per foot Ps NC

10 inch

PERFORMANCE DATA - RETURN SLR,SLG,RLR,RLG

O12mm Spacing - 0 DEFLECTION

*IMPERIAL UNITS

SYMBOLS

CONDITIONS

CFM : Air volume in cubic feet per minute.

PS : Negative static pressure in inches water gauge.

N.C. : Noise Criteria

* Return

* Noise Criteria is based on (10 dB) room attenuation.

* Damper is fully open.

* Data is based on 1ft length.

LINEAR GRILLES & REGISTERS

PERFORMANCE DATA

Page 18: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

90

120

150

180

210

240

270

210

240

270

300

330

360

405

210

270

300

330

360

405

450

240

270

300

330

360

405

450

270

360

450

540

630

720

810

420

480

540

600

660

720

810

315

405

450

495

540

608

675

288

324

360

396

432

486

540

15

17

19

21

23

30

37

19

23

29

32

35

38

41

15

21

28

30

32

36

39

15

21

24

28

31

35

38

0.001

0.014

0.026

0.039

0.051

0.078

0.105

0.031

0.049

0.062

0.077

0.096

0.111

0.139

0.011

0.019

0.023

0.028

0.032

0.042

0.052

0.005

0.006

0.008

0.009

0.011

0.014

0.017

4 Inch (16mm

space) An=0.333

sq.ft. Ak=0.248

sq.ft.

6 Inch (16mm

space) An=0.500

sq.ft. Ak=0.347

sq.ft.

8 Inch (16mm

space) An=0.667

sq.ft. Ak=0.495

sq.ft.

10 Inch (16mm

space) An=0.834

sq.ft. Ak=0.665

sq.ft.

CFM : Air volume in cubic feet per minute.

Ak : Effective Face Area in feet square per feet length

An : Neck Area in feet square per feet length

Vn : Neck Velocity in feet per minute

Pt : Total Preasure in inches water gauge

Th : Throw in feet

N.C. : Noise criteria

* Supply 0* Vertical blades deflection: 0 deflection

* Noise Criteria values are based on (10 dB) room attenuation

* Throw Figures are measured for Linear Grilles fixed at 6” from the Ceiling

* Damper is fully open

* Data is based on 1ft length

SYMBOLS

CONDITIONS

CORRECTIONS ON NOISE CRITERIA FOR OTHER LENGTHS

Length 3ft 6ft 10ft

(+9)(+7)(+4)N.C.

THROW

Air Terminal Velocity (FPM) vs. Throw (Ft)O

4” Height - 16mm Spacing - 0350

300

250

200

150

100

50

0

6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM

700 CFM

500 CFM

300 CFM

Air Terminal Velocity (FPM) vs. Throw (Ft)O

6” Height - 16mm Spacing - 0

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM

300

250

200

150

100

50

0

700 CFM

500 CFM

300 CFM6

2’6

4’6

6’6

8’6

10

’6”

12

’6”

14

’6”

16

’6”

18

’6”

20

’6”

22

’6”

24

’6”

Air Terminal Velocity (FPM) vs. Throw (Ft)O

8” Height - 16mm Spacing - 0

300

250

200

150

100

50

0

6”

2’6

4’6

6’6

8’6

10

’6”

12

’6”

14

’6”

16

’6”

18

’6”

20

’6”

22

’6”

24

’6”

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM 850 CFM

700 CFM

500 CFM

1100 CFM

900 CFM

700 CFM

6”

2’6

4’6

6’6

8’6

10

’6”

12

’6”

14

’6”

16

’6”

18

’6”

20

’6”

22

’6”

24

’6”

300

250

200

150

100

50

0

Throw, Ft

Air Terminal Velocity (FPM) vs. Throw (Ft)O

10” Height - 16mm Spacing - 0

Air

Te

rmin

al V

elo

cit

y, F

PM

O O16mm Spacing - 0 DEFLECTION - VERTICAL BLADES AT 0

SLR, SLG, RLR, RLGPERFORMANCE DATA - SUPPLY

PERFORMANCE DATA

LINEAR GRILLES & REGISTERS

WIDTH CFM per foot Vn Pt NC

*IMPERIAL UNITS

Page 19: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

90

120

150

180

210

240

270

180

210

240

300

360

420

450

210

240

270

300

330

360

405

210

240

300

330

405

450

480

4 Inch (16mm

space) An=0.333

sq.ft. Ak=0.184

sq.ft.

6 Inch (16mm

space) An=0.500

sq.ft. Ak=0.271

sq.ft.

8 Inch (16mm

space) An=0.667

sq.ft. Ak=0.384

sq.ft.

10 Inch (16mm

space) An=0.834

sq.ft. Ak=0.532

sq.ft.

PERFORMANCE DATA - SUPPLY

WIDTH CFM per foot Vn

15

19

23

27

31

36

41

19

24

29

33

36

39

41

17

22

25

30

33

36

39

15

19

25

29

36

39

41

0.001

0.026

0.051

0.076

0.101

0.130

0.159

0.048

0.061

0.079

0.102

0.132

0.161

0.176

0.021

0.028

0.035

0.047

0.055

0.067

0.080

0.010

0.013

0.021

0.024

0.039

0.047

0.052

SLR, SLG, RLR, RLG

Pt NC

*IMPERIAL UNITSTHROW

270

360

450

540

630

720

810

360

420

480

540

600

660

900

315

360

405

450

495

540

585

252

288

360

396

486

540

576

CFM : Air volume in cubic feet per minute.

Ak : Effective Face Area in feet square per feet length

An : Neck Area in feet square per feet length

Vn : Neck Velocity in feet per minute

Pt : Total Preasure in inches water gauge

Th : Throw in feet

N.C. : Noise criteria

* Supply 0 * Vertical blades deflection: 45 deflection

* Noise Criteria values are based on (10 dB) room attenuation

* Throw Figures are measured for Linear Grilles fixed at 6” from the Ceiling

* Damper is fully open

* Data is based on 1ft length

SYMBOLS

CONDITIONS

CORRECTIONS ON NOISE CRITERIA FOR OTHER LENGTHS

Length 3ft 6ft 10ft

(+9)(+7)(+4)N.C.

LINEAR GRILLES & REGISTERS

PERFORMANCE DATA

Air Terminal Velocity (FPM) vs. Throw (Ft)O4” Height - 16mm Spacing -45

350

300

250

200

150

100

50

06” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM

700 CFM

500 CFM

300 CFM

Air Terminal Velocity (FPM) vs. Throw (Ft)O6” Height - 16mm Spacing -45

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM

350

300

250

200

150

100

50

0

700 CFM

500 CFM

300 CFM

6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”

Air Terminal Velocity (FPM) vs. Throw (Ft)O

8” Height - 16mm Spacing - 45

350

300

250

200

150

100

50

0

Throw, Ft

Air

Te

rmin

al V

elo

cit

y, F

PM 850 CFM

700 CFM

500 CFM

1100 CFM

900 CFM

700 CFM

Throw, Ft

Air Terminal Velocity (FPM) vs. Throw (Ft)O

10” Height - 16mm Spacing - 45

6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”

350

300

250

200

150

100

50

0

6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”

Air

Te

rmin

al V

elo

cit

y, F

PM

O O16mm Spacing - 0 DEFLECTION - VERTICAL BLADES AT 45

16

Page 20: WE SHAPE AIR · 2016. 9. 28. · The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in cooling, heating or air ventilation application.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

90

120

150

180

210

240

270

210

240

270

300

330

360

405

240

270

300

330

360

405

450

300

330

360

390

405

450

480

0.001

0.013

0.025

0.036

0.048

0.060

0.080

0.030

0.040

0.055

0.070

0.085

0.105

0.140

0.020

0.030

0.040

0.050

0.060

0.070

0.080

0.025

0.030

0.035

0.040

0.045

0.055

0.065

15

21

26

32

37

43

44

17

29

30

34

33

37

40

15

16

34

42

43

45

47

15

17

21

37

43

40

56

4 inch

6 inch

8 inch

WIDTH CFM per foot Ps NC

10 inch

PERFORMANCE DATA - RETURN SLR,SLG,RLR,RLG

O16mm Spacing - 0 DEFLECTION

*IMPERIAL UNITS

SYMBOLS

CONDITIONS

CFM : Air volume in cubic feet per minute.

PS : Negative static pressure in inches water gauge.

N.C. : Noise Criteria

* Return

* Noise Criteria is based on (10 dB) room attenuation.

* Damper is fully open.

* Data is based on 1ft length.

LINEAR GRILLES & REGISTERS

PERFORMANCE DATA