“We do not inherit the earth from our parents, we borrow it from our children” – Chief...

39
“We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle

Transcript of “We do not inherit the earth from our parents, we borrow it from our children” – Chief...

Page 1: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

• “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle

Page 2: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

• Energy use has changed a great deal since people relied solely on the sun, their own strong bodies or beasts of burden as energy resources.

Page 3: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Installed capacity (MW)-over the years

1,700 4,60013,000

28,000

66,000

1,12,058

159398173626

199877

223344227357

0

50,000

1,00,000

1,50,000

2,00,000

2,50,000

Data Source: CEA Website

Page 4: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Installed capacity (MW)-RES 1985-2013 in India

0 18 32 902 1,628

7,761

2450427542

0

5,000

10,000

15,000

20,000

25,000

30,000

1985 1990 1992 1997 2002 2007 2012 2013Data Source: CEA Website

Page 5: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Coal 58.6%

Hydro17.4%Wind &

Other12.4%

Diesel 0.5%

Nuclear 2.1%

Gas 9.0%

GENERATING CAPACITY IN THE COUNTRY (As on 31.08.2013 227357 MW)

Fuel wise Installed Capacity

(133188 MW)

(20381 MW)

(4780 MW)

(1200 MW)

(39623 MW)

(28184 MW)

Data Source: CEA Website

Page 6: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Per Capita Consumption of Electricity in India

Page 7: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

• Jawaharlal Nehru National Solar Mission aims to deploy 20000 MW of solar power by 2022

• Grid connected solar generation to ramp up to 1000 MW by 2013 and to 4000 MW by 2017

• A&N Island heavily depends on Diesel based Power Generation (63.2 MW out of 68.5 MW)

• A&N Govt plans to add 13 MW RE power including Solar

BACKGROUND OF 5 MW PV PROJECT

Page 8: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Schematic diagram

Page 9: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

SOLAR CELLS

• A solar cell (also called a photovoltaic cell) is an electrical device that converts the energy of light directly into electricity by the photovoltaic effect.

• It is a form of photoelectric cell (in that its electrical characteristics—e.g. current, voltage, or resistance—vary when light is incident upon it) which, when exposed to light, can generate and support an electric current.

Page 10: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Technology Maturity Efficiency Applicability & Availability in India

Mono-crystalline silicon Mature, First Generation 15-18% High, proven, High

Poly-crystalline silicon Mature, First Generation 13-16% High, proven High

Thin Film Scalable, Second Generation 8-11% High, emerging, Limited

Concentrated PV Scalable, Second Generation 20-30% Medium, expensive, unproven, Limited

TECHNICAL ALTERNATIVES FOR SOLAR FIELD

Page 11: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.
Page 12: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Thin Film (8-11%) Polycrystalline Mono-crystalline

'Hybrid‘ (17 – 19%)13 - 16% 15 - 18%

Major types of PV cells

Page 13: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

PERFORMANCE LOSSES IN PV MODULES

• PV cells are sensitive to variance in ambient temp and irradiance levels (for 310 C amb and 800 kwh/m2 irradiance level, module temp would be around 460 C and around 10% loss in efficiency)

• Array mismatch loss due to variations in I-V characteristics of modules during manufacturing (could vary bet 1.3 to 1.9%)

• Cable loss, Inverter loss, Transformer loss etc.,• Cell efficiency degradation (approx 1% per annum)

Page 14: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Modules: 235 Wp Mono Crystalline Cell

Cells per Module: 60

No of Modules: 21312

No of Modules per Structure: 24

No of Structures: 888

No of Foundations per Structure: 5

Total No of Foundations: 4440

Photo Voltaic Module used in 5 MW Project at Andaman

Page 15: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Solar PV Value Chain

Solar cell

Solar PV module

Solar PV Array

Polysilicon

Ingot &Wafer

Page 16: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.
Page 17: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.
Page 18: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

SMA INVERTERS

• Sunny Central 800 CP Model• Nominal AC output 800 kVA at @ 500 C• Continuous AC power @ 250 C 880 kVA• Nominal AC Voltage 360 V +/- 10%• Internal consumption in operation <1500 W

and in standby <100W• Max efficiency 98.6%• Operation temp range -200 to 500 C and RH

15% to 95%

Page 19: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

SMA INVERTERS- GRID MANAGEMENT FUNCTIONS

• Remote controlled power reduction in case of Grid overload– Nominal power value transmitted to the Inverter

via a ripple control receiver in combination with SMA Power reducer box

– Typical limit values are 100,60,30 or 0 % of nominal power

• Freq dependent control of active power– Grid freq > 50.2 Hz the inverter automatically

reduces the fed-in of active power as per the definable characteristic curve

Page 20: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

SMA INVERTERS- GRID MANAGEMENT FUNCTIONS

• Limited Dynamic Grid Support– Continues to feed the Grid after short term

voltage drops, as long as voltage is within the defined window

• Dynamic Grid Support– LVRT (Low Voltage Ride Through)– Stays connected during voltage drops and

supports the Grid by feeding reactive power

Page 21: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

• a technique that grid-tie inverters, solar battery chargers and similar devices use to get the maximum possible power from solar panels

• Solar cells have a complex relationship between solar irradiation, temperature and total resistance that produces a non-linear output efficiency which can be analyzed based on the I-V curve.

• It is the purpose of the MPPT system to sample the output of the cells and apply the proper resistance (load) to obtain maximum power for any given environmental conditions

• MPPT devices are typically integrated into an electric power converter system that provides voltage or current conversion, filtering, and regulation for driving various loads, including power grids, batteries, or motors

Maximum power point tracking (MPPT)

Page 22: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.
Page 23: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

• Photovoltaic cells have a complex relationship between their operating environment and the maximum power they can produce. The fill factor, abbreviated FF, is a parameter which characterizes the non-linear electrical behaviour of the solar cell.

• Fill factor is defined as the ratio of the maximum power from the solar cell to the product of Open Circuit Voltage Voc and Short-Circuit Current Isc.

• For any given set of operational conditions, cells have a single operating point where the values of the current (I) and Voltage (V) of the cell result in a maximum power output. These values correspond to a particular load resistance, which is equal to V / I as specified by Ohm's Law. The power P is given by P=V*I.

• A photovoltaic cell, for the majority of its useful curve, acts as a constant current source.

Page 24: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

• At a photovoltaic cell's MPP region, its curve has an approximately inverse exponential relationship between current and voltage. This is known as the maximum power point (MPP) and corresponds to the "knee" of the curve.

• A load with resistance R=V/I equal to the reciprocal of this value draws the maximum power from the device. This is sometimes called the characteristic resistance of the cell. This is a dynamic quantity which changes depending on the level of illumination, as well as other factors such as temperature and the age of the cell. If the resistance is lower or higher than this value, the power drawn will be less than the maximum available, and thus the cell will not be used as efficiently as it could be

• Maximum power point trackers utilize different types of control circuit or logic to search for this point and thus to allow the converter circuit to extract the maximum power available from a cell.

Page 25: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

P V Modules Erection in Progress

Page 26: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.
Page 27: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.
Page 28: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Operation & Maintenance (O&M)

• One Year O&M Contract included in EPC Contract at a Value of Rs 45,00,000.

• Security during One Year O&M in the Scope of EPC Contractor.

• Insurance during O&M Phase – Fire & Allied Perils / Risks in NTPC Scope, All others in EPC Contractors Scope

Page 29: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

EmploymentOpportunities in

Renewable energy sector

TrainingDemonstration

Implementation of projects at field level

Maintenance of systems

R &D Activity & designing

new systems

Consultancy services viz.

surveys, system design etc

Establishment of Renewable Energy

Power Plants

Marketing , Retail sales

Outlets/ Aditya shops

Manufacturing

Page 30: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

The 19.9 MW Gemasolar solar plant in Spain features 15 hours of storage and can supply power 24 hours a day

Page 31: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

GemasolarThe plant is a 140 m high solar power tower, using molten salt as its heat transfer fluid and energy storage medium.

Gemasolar is the first commercial solar plant with central tower receiver and molten salt heat storage technology. It consists of a 185 ha solar field that has a 140-m high tower receiver, a power island and 2650 heliostats, each 120 m2 and distributed in concentric rings around the tower.

The most innovative aspects of the plant, are its molten salt receiver, its heliostats aiming system and its control system. In addition, its storage system allows it to produce electricity for 15 hours without sunlight (at night or on cloudy days).

Page 32: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

Gemasolar

This storage capacity makes its solar power manageable so that it can be supplied based on demand. The plant has already been able to supply a full day of uninterrupted power supply to the grid, using thermal transfer technology

Gemasolar, with its 19.9 MW of power, can supply 110 GWh per year — enough to supply power to 27,500 homes. The plant has been operational since May 2011

Page 33: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

19 MW solar park in Germany

Page 34: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

MICRO GRID- THE FUTURE GRID• A microgrid is an electrical system that includes multiple

loads and distributed energy resources that can be operated in parallel with the broader utility grid or as an electrical island

• Generation and loads in a microgrid are usually interconnected at low voltage

• Microgrid generation resources can include fuel cells, wind, solar, or other energy sources. The multiple dispersed generation sources and ability to isolate the microgrid from a larger network would provide highly reliable electric power

Source: Wikipedia

Page 35: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

MICRO GRID- THE FUTURE GRID• Micro-grids were proposed in the wake of the July 2012

India blackout:– Some technology sources and USAID proposed that

another widespread outage could be prevented by integrated network of microgrids and distributed generation connected seamlessly with the main grid via a superior smart grid technology which includes automated fault detection, islanding and self-healing of the network.

Source: Wikipedia

Page 36: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

A local microgrid in Sendai, Japan

Source: Wikipedia

Page 37: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.

MICRO GRID- CHALLENGES• For reasons of reliability, distributed generation

resources would be interconnected to the same transmission grid as central stations

• Technical problems arise in the areas of power qauality, voltage stability, harmonics, reliability, protection, and control

• Behaviour of protective devices on the grid must be examined for all combinations of distributed and central station generation.

• A large scale deployment of distributed generation may affect grid-wide functions such as frequency control and allocation of reserves

Source: Wikipedia

Page 38: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.
Page 39: “We do not inherit the earth from our parents, we borrow it from our children” – Chief Seattle.