WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT...

14
WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE

Transcript of WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT...

Page 1: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

WAYNE KINNEY’S REALLY TALL

ENGINEERED ROCKED RIFFLES (ERR)

CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL

STRUCTURE

Page 2: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

STABILIZE HEADCUTS FIRST,

THEN WORRY ABOUT BANK INSTABILITY

SECOND

Page 3: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

DESIGN & CONSTRUCTION

OVERSIGHT BY WAYNE KINNEY,

PREZ, MIDWEST STREAMS, INC. OAKDALE, IL.

Mini case study: 1 of 10

Page 4: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

A 4.7 ft tall ERR, Big Creek, Union County, IL. {rural, sand-gravel, pool-

riffle-pool, meandering, incised} Designed by Wayne Kinney

Photo by Derrick 2/7/2007

Looking DS at the 4.7 ft tall Engineered Rocked Riffle

in the proper location in the crossing between two

bends

Mini case study: 2 of 10

Page 5: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

PoolPool

Key

Bank protection

Key

ERR

Bank protection

Glide

Page 6: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

A 4.7 ft tall ERR, Big Creek, Union County, IL. Designed by Wayne Kinney

Photo by Derrick 2/7/2007

Looking at the key, flow right to left. US ERR slope is angle of repose, DS ERR slope is 20 to 1.

Mini case study: 3 of 10

Page 7: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

A 4.7 ft tall ERR, Big Creek, Union County, IL. Designed by Wayne Kinney

Photo by Derrick 2/7/2007

Key is dug 3 ft deep into substrate & up each bank. Stone is IL-DOT RR5-well-

graded stone with a top size of 400 pounds.

Mini case study: 4 of 10

Page 8: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

A 4.7 ft tall ERR, Big Creek, Union County, IL. Designed by Wayne Kinney

Photo by Derrick 2/7/2007

Looking DS. Uniform 20 to 1 slope, roughness dissipates energy &

assists in fish passage.

Mini case study: 5 of 10

Page 9: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

A 4.7 ft tall ERR, Big Creek, Union County, IL. Designed by Wayne Kinney

Photo by Derrick 2/7/2007

Flood flow crested 5 ft above banks (30 ft over the crest of

the ERR) with no damage

Mini case study: 6 of 10

Page 10: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

A 4.7 ft tall ERR, Big Creek, Union County, IL. Designed by Wayne Kinney

Photo by Derrick 2/7/2007

Looking US at the 4.7 ft tall Engineered

Rocked Riffle

Mini case study: 7 of 10

Page 11: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

A 4.7 ft tall ERR, Big Creek, Union County, IL. Designed by Wayne Kinney

Photo by Derrick 2/7/2007

Mini case study: 8 of 10

Page 12: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

Photo by Derrick 2/7/2007

Mini case study: 9 of 10

Looking US. A thing of beauty!! Stone was track-walked to increase stability

Page 13: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

A 4.7 ft tall ERR, Big Creek, Union County, IL. Designed by Wayne Kinney

Photo by Derrick 2/7/2007

Looking US, note riprap

bank protection.

Mini case study: 10 of 10

Page 14: WAYNE KINNEY’S REALLY TALL ENGINEERED ROCKED RIFFLES (ERR) CASE STUDY: ERR #12, WHICH IS A 4.7 FT TALL STRUCTURE.

This PowerPoint presentation was developed & built by Dave Derrick.

Any questions or comments, call my personal cell @ 601-218-7717, or email @ [email protected]

Enjoy the information!!