Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.
-
Upload
ashlyn-breakfield -
Category
Documents
-
view
212 -
download
0
Transcript of Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.
![Page 1: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/1.jpg)
Waverail B.V.
S.L.A. Heat exchanger Total projectsservices
Fire line Water and gaslines
![Page 2: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/2.jpg)
Safety Line Aluminium
• Methylbromide pollution in West of Netherland
• Pollution in drinkingwater • Innovation by Egeplast and Conval,
for non-permeable pipesystem; S.L.A. is born
• KIWA approval on pipe and coupling• Now used from 25 till 630 mm
![Page 3: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/3.jpg)
Safety Line Aluminium
![Page 4: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/4.jpg)
Safety Line Aluminium
• Couplings in accordance to BRL-545/01• Same couplings are used in our switch
point heating system
![Page 5: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/5.jpg)
Waverail
WaverailSwitchpoint Heating with
Earth energy.
![Page 6: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/6.jpg)
Productprogram WaVe
• Non permeable energy exchangers in the Earth, produced en tested by Conval.
• Kiwa-ATA certified fluid in all the primary en secundairy systems.
• Kiwa tested en approved pipes & couplings.
• Heat pumps from 3 – 500 KW in all kinds of variety.
![Page 7: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/7.jpg)
The strength of our system
• Monitoring & datalogging with GSM-R from Avic
• No weather-station needed witch declines the failures.
• All pipes and couplings 100% non-permeable
completereliable
heating system
Co-partnershipwith our
key-suppliers
Producing and innovationby Waverail
Serviceby Waverail
![Page 8: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/8.jpg)
![Page 9: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/9.jpg)
NS Ravenstein
0
10
20
30
40
50
60
1 4 7 10 13 16 19 22 25 28 31 34 37 40 43
tijd
switch in switch out earth out earth in railtemp.
![Page 10: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/10.jpg)
![Page 11: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/11.jpg)
![Page 12: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/12.jpg)
Advantages:
• No weather station needed, swithing on rail temperature
• Old CBG systems can be integrated in heatpump system
• Lower energy costs• Small pipe diameters• Integrated datalogger and
monitoring• Temperature range from 50 to 75
degrees
![Page 13: Waverail B.V. S.L.A. Heat exchangerTotal projects services Fire line Water and gas lines.](https://reader035.fdocuments.net/reader035/viewer/2022081602/55169ac8550346f0208b4a4c/html5/thumbnails/13.jpg)