Waterproof Air Barrier: StoGuard Waterproof Air Barrier...Waterproof Air Barrier: StoGuard...
Transcript of Waterproof Air Barrier: StoGuard Waterproof Air Barrier...Waterproof Air Barrier: StoGuard...
Waterproof Air Barrier:StoGuard®Waterproof Air Barrier
Frame ConstructionSeries 20.xxMarch 2014
®
ATTENTION
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional, general contractor or builder. They should be installed in accordance with those specifications and Sto’s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections, for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building components or assemblies, of for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or building may result in serious damage to Sto products, and to the structure of the building or its components.
STO CORP. DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED EXCEPT FOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO’S WARRANTY PROGRAMS WHICH ARE SUBJECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers, please refer to the Sto Corp. website, www.stocorp.com.
www.stocorp.com
Property of Sto Corp.All Rights Reserved.
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Non-absorptive Cladding and Cavity Walls
Detail No.: 20.00a
Supporting structure(steel or woodframing)
Substrate
StoGuard jointtreatment
StoGuardwaterproof air barriermembrane
Low-expanding ure-thane spray foam,trimmed flush withsheathing surface.
StoGuard jointtreatment
StoGuard waterproofair barrier membrane
EDG
E
Typical SheathingJoint
Oversized SheathingJoint
1] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Examples of non-absorptivecladding: fiber-cement board,wood or vinyl siding, metalpanel system with sealedjoints.
4] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions.
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Absorptive Cladding
Detail No.: 20.00b
Supporting structure(steel or woodframing)
Substrate
StoGuard® jointtreatment
StoGuardwaterproof air barriermembrane
Slip sheet/water-resistive barrier(Note 3)
Low-expanding ure-thane spray foam,trimmed flush withsheathing surface.
StoGuard jointtreatment
StoGuard waterproofair barrier membrane
Water-resistive barrierand slip sheet (Note 3)
EDG
E
Typical SheathingJoint
Oversized SheathingJoint
1] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Water-resistive barrier/slip sheet, minimum #15Grade D building paper,required behind claddingsuch as portland cementstucco and adhered masonryveneer. For wood-basedsheathing use minimum 60-minute, Grade D paper whenbacked with Sto AirSeal™ orStoGuard VaporSeal™
4] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions.
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
StoGuard® with Furring and Backer Board(Engineered Wall Design)
Detail No.: 20.00c
Supporting structure(steel or woodframing)
Substrate
StoGuard jointtreatment
StoGuardwaterproof air barriermembrane
Wood or metal “Z”furring attached toframing.
Backer board (Note 3)
EDG
E
1] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Engineered wall design musttake into account furring andcladding attachment, cantile-vered load imposed by clad-ding on fasteners, fire andflame propagation, and otherdesign considerations to con-form with or gain compliancewith local code requirements.
4]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions.
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Sto DrainScreen™
Detail No.: 20.00d
Supporting structure(steel or woodframing)
Substrate
StoGuard jointtreatment
StoGuardwaterproof air barriermembrane
Sto DrainScreen™(note 4)
Water-resistive barrier(Note 4)
EDG
E
AbsorptiveCladdings
1] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Examples of non-absorptivecladdings include fiber-cement board, wood andvinyl siding, metal panel sys-tems with sealed joints, andbrick or stone cavity walls
4] Use Sto DrainScreen™ tocreate a cavity to promotedrainage and drying of wallassemblies.
5] Water-resistive barrier,minimum #15 Grade Dbuilding paper, requiredbehind portland cement stuc-co and adhered masonryveneer. For wood-based sub-strates use minimum 60-minute, Grade D paper whenbacked by Sto AirSeal™ orStoGuard VaporSeal™.
6] Refer to Sto specificationsand product bulletins fordetailed information on sub-strates and Sto materialoptions.
Non-absorptiveCladdings (note 3)
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Continuous Insulation - Brick Cavity or Other Cladding
Detail No.: 20.00e
Supporting structure(steel or woodframing)
Substrate
StoGuard jointtreatment
StoGuardwaterproof air barriermembrane
Continuous Insulation(Note 3)
Sto DrainScreen™
EDG
E
1] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B)StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Continuous foam plastic insu-lation must be approved andin conformance with IRC Sec-tion 316 and IBC Section 2603(note required fire tests for useon noncombustibleconstruction). Consult withcladding manufacturer forrequired supports, attachmentand limitations for assembliesinvolving continuous insulation.
4]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions.
Brick Cavity Wall
Siding
R
www.stocorp.com
Date: March 2013
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Continuous Insulation - Portland Cement Stucco andAdhered Masonry Veneer
Detail No.: 20.00f
Supporting structure(steel or woodframing)
Substrate
StoGuard jointtreatment
StoGuardwaterproof air barriermembrane
Continuous Insulation(Note 4)
Water-resistive barrier(Note 3)
Sto DrainScreen™
Tape or seal insulationboard joints
EDG
E
1] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Water-resistive barrier/slip sheet, minimum #15Grade D building paper,required behind claddingssuch as portland cementstucco and adhered masonryveneer. For wood-basedsheathing use minimum 60-minute, Grade D paper whenbacked with Sto AirSeal™ orStoGuard VaporSeal™
4] Continuous foam plastic insu-lation must be approved andin conformance with IRC Sec-tion 316 and IBC Section 2603(note required fire tests for useon noncombustibleconstruction). Consult withcladding manufacturer forrequired supports, attachmentand limitations for assembliesinvolving continuous insulation.
5]Refer to Sto specifications andproduct bulletins for detailedinformation on substrates andSto material options.
Option 1 with paperwater-resistivebarrier
Option 2 withdrainage mat and
continuous insulation
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Inside Corner - Common Substrate
Detail No.: 20.01
EDG
E
1] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Supporting structure(steel or woodframing)
Substrate
StoGuard jointtreatment or StoGuardTape
StoGuardwaterproof air barriermembrane
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Outside Corner
Detail No.: 20.02
1] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Best practice is to overlapsheathing as shown in detail“A”. Detail “B” presents anoption to accommodateminor constructionvariations: maximum 5/8-in.x 5/8-in. (16 mm x 16 mm)gap at corner.
4]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Supporting structure(steel or woodframing)
Sheathing(overlapping at corner)(Note 3)
StoGuard® jointtreatment
StoGuard®
waterproof air barriermembrane
Sheathing (stoppedshort at edge offraming) (Note 3)
Spray foam applied tofill space betweensheathing boards andthen trimmed to formcorner support forStoGuard® system.
StoGuard® jointtreatment
StoGuard®
waterproof air barriermembrane
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Detail No.: 20.03a
EDG
E
1] StoGuard detail componentoptions:
A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard MeshC) StoGuard Fabric with
StoGuard waterproof airbarrier membrane
D) StoGuard RapidSeal™with StoGuard Mesh
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Continuous foam plasticinsulation must be approvedand in conformance with IRCSection 316 and IBC Section2603 (note required fire testsfor use on noncombustibleconstruction).
4} Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier and slipsheet required behind porouscladdings not shown. Referto Sto Detail 20.00b foradditional information.
Supporting structure
Substrate
Masonry anchorsealed with Sto-Guard® detailcomponent (A or B)
StoGuardwaterproof/air barriermembrane (Note 2)
Continuous insulation(Note 3)
StoGuard detail com-ponent (Note 1)
Metal flashing set insealant
Foundation water-proofing
Brick Ledge at Foundation with Masonry Anchors - Steel Frame
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Masonry Anchor Backer Seal
Detail No.: 20.03c
EDG
E
1] StoGuard detail componentoptions:
A) StoGuard RapidFillB) StoGuard RapidSeal™
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Caution: All fasteners shouldbe into framing with fastenerhead snug to tie surface.Remove fasteners and sealall penetrations where studsare missed using StoGuarddetail component orcompatible sealant.
4]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Option A: StoGuarddetail component
Substrate
StoGuard detailcomponent
StoGuardwaterproof air barriermembrane
Masonry anchor
Option B: StoGuardTape
StoGuard Tape
StoGuardwaterproof air barriermembrane
Masonry anchor
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Termination at Grade - Sheathing Flush with Foundation
Detail No.: 20.10a
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard MeshC) StoGuard Fabric with
StoGuard waterproof airbarrier membrane
D) StoGuard RapidSeal™with StoGuard Mesh
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier /slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Supporting structure(steel or woodframing)
Substrate
StoGuard®
waterproof air barriermembrane
StoGuard® detailcomponent
Flashing
StoGuard® TransitionMembrane (Sto detail20.10TM)(protect exposed areawith coating)
Cementitious foundationwaterproofing or dampproofing
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Termination at Grade - Sheathing Overlapping Foundation
Detail No.: 20.10b
EDG
E
Supporting structure(steel or woodframing)
Substrate
StoGuard®
waterproof air barriermembrane
StoGuard® detailcomponent
Flashing
StoGuard® transitionMembrane (Sto detail20.10TM)(protect exposed areawith coating)
Cementitious foundationwaterproofing or dampproofing
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard MeshC) StoGuard Fabric with
StoGuard waterproof airbarrier membrane
D) StoGuard RapidSeal™with StoGuard Mesh -
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier /slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Rough Opening Protection with StoGuard Fabric
Detail No.: 20.20F
EDG
E
1] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
2]Prepare opening prior to theinstallation of the window ormechanical equipment.Provide sill wedge or othermeans of positive slope toexterior at sill.
3] Incorporate flashing as illustrated in 20.23a or as perother details where flashingis shown.
4] The complete installation ofwindow or mechanicalequipment must include anair seal between the objectand the StoGuard protection,inbound of the outer perime-ter weather seal.
5] See Sto Detail 20.21 forpreparation of punchedstuds used to frame roughopenings.
6]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Step 1At sill-to-jamb intersectionsonly, embed strip ofStoGuard® Fabric along fram-ing joint to full depth of open-ing.
Apply StoGuard® waterproofair barrier membraneliberally at corners of roughopenings and placeStoGuard® RediCorner™ inwet membrane. Use brush,roller, trowel or taping knife tofully embed StoGuard®
RediCorner™.
Step 2Immediately apply StoGuard®
waterproof air barrier mem-brane liberally to inside ofopening and around outside ofhead, sill and jambs. CenterStoGuard® Fabric on outsidecorners and press into wetmembrane along the head,jambs, and sill with minimum2" (50 mm) overlaps of adja-cent fabric. Use brush, roller,trowel or taping knife to fullyembed StoGuard® Fabric.
Step 3Immediately coat the entiresurface of the wall and insidesurfaces of rough opening withStoGuard® waterproof air bar-rier membrane to produce avoid and pinhole free surface.Edges of StoGuard®
RediCorners and StoGuard®
Fabric must lay flat, bewrinkle-free, be fullyembedded in the membraneand fully adhered to thesubstrate or previous layer ofStoGuard® Fabric.
Slope
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Rough Opening Protection with StoGuard Fabric andStoGuard Tape at Sill (for abuse-resistance at sill)
Detail No.: 20.20FT
EDG
E
2] StoGuard waterproof airbarrier membrane
options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
2]Prepare opening prior to theinstallation of the window ormechanical equipment.Provide sill wedge or othermeans for positive slope toexterior at sill.
3] Incorporate flashing as illus-trated in 20.23a or as perother details where flashingis shown.
4] The complete installation ofwindow or mechanicalequipment must include anair seal between the objectand the StoGuard protection,inbound of the outer perime-ter weather seal.
5] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b for addi-tional information.
Step 1Apply minimum 2" (50 mm) wideStoGuard Tape in diagonalstrips at rough opening sill cor-ners.
Step 2Apply minimum 6" (150 mm)wide StoGuard Tape to sill andextending minumum 4-inches(102 mm) up jambs.
Step 3Apply StoGuard waterproof airbarrier membraneliberally to head/jambcorners. Install StoGuardRediCorners™ in wet mem-brane. Use brush, roller, trowelor taping knife tofully embed StoGuardRediCorners™.
Step 4Immediately coat head andjambs liberally with StoGuardwaterproof air barrier membrane.Center 6" (150 mm) wide Sto-Guard Fabric on outside cornersof opening head and jambs andembed in wet membrane withminimum 2" (50 mm) overlaps ofadjacent fabric and StoGuardTape.
Step 5Immediately coat surface of thewall and into rough openinghead and jambs with StoGuardwaterproof air barrier membraneto produce a void and pinholefree surface. Edges of StoGuardRediCorners™, StoGuard Fabricand StoGuard Tape must lay flat,wrinkle-free, and be fully embed-ded in the membrane and fullyadhered to the substrate or pre-vious layer of StoGuard Fabric.
Slope
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Step 2
Step 1
Slope
Step 3
Step 4
Rough Opening Protection Sto Gold Fill® and StoGuard® Mesh
Detail No.: 20.20M
EDG
E
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
2]Prepare opening prior to theinstallation of the window ormechanical equipment.Provide sill wedge or othermeans for positive slope toexterior of sill.
3] Incorporate flashing as illus-trated in 20.23a or as perother details where flashingis shown.
4] The complete installation ofwindow or mechanicalequipment must include anair seal between the objectand the StoGuard protection,inbound of the outer perime-ter weather seal.
5]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Step 1Place 2" (50mm) wide stripof Sto Guard Mesh lappingonto face of wall diagonallyat corners of opening.
Step 2Place minimum 4“ (100mm)StoGuard Mesh at allsheathing joints
Wrap sill with 9” (230mm)wide StoGuard mesh return-ing up the jambs a minimumof 4” (100mm)
Step 3Wrap jambs with minimum9” (230mm) wide StoGuardMesh, lapping minimum 2.5“(64mm) over extension fromsill, then wrap head.
Coat StoGuard Mesh withSto Gold Fill®
Step 4Coat the entiresurface of the wall and intorough opening withStoGuard waterproof airbarrier membrane.
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Rough Opening Protection with StoGuard® RapidSeal™
Detail No.: 20.20R
EDG
E
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
2]Prepare opening prior to theinstallation of the window ormechanical equipment.
3] Incorporate flashing as illus-trated in 20.23a or as perother details where flashingis shown. Provide sill wedgeor other means for postiveslope to exterior at sill.
4] The complete installation ofwindow or mechanicalequipment must include anair seal between the objectand the StoGuard protection,inbound of the outer perime-ter weather seal.
5] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Step 1Apply generous bead of Sto-Guard RapidSeal aroundinner and outer perimeter ofrough opening.
Step 2Tool beads of StoGuardRapidSeal to a uniformcontinuous minimum 12-milthickness. Coat sheathingsurface nominal 2-inches(51 mm) around roughopening perimeter withStoGuard RapidSeal
Step 3Apply StoGuard waterproofair barrier membrane toexterior sheathing surfaceup to edge of opening.(Alternatively, StoGuardwaterproof air barrier mem-brane may be applied toexterior sheathing surfacebefore installation ofStoGuard RapidSeal.) Incases where StoGuardVaporSeal is the waterproofair barrier, coat all StoGuardRapidSeal with StoGuardVaporSeal to providecontinuous vapor barrier.
Assure that final surface ofStoGuard RapidSeal iscontinuous at joints, seamsbetween materials, andframed corners.
Slope
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Rough Opening Protection with StoGuard Tape
Detail No.: 20.20T
EDG
E
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
2]Prepare opening prior to theinstallation of the window ormechanical equipment.Provide sill wedge or othermeans for positive slope toexterior at sill.
3] Incorporate flashing as illus-trated in 20.23a or as perother details where flashingis shown.
4] The complete installation ofwindow or mechanicalequipment must include anair seal between the objectand the StoGuard protection,inbound of the outer perime-ter weather seal.
5] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Step 1Apply minimum 2" (50 mm)wide StoGuard Tape in diag-onal strips at rough openingcorners.
Step 2Apply minimum 6" (150 mm)wide StoGuard Tape to silland extending minumum 4-inches (102 mm) up jamb.
Step 3Apply minimum 6" (150 mm)wide strips of StoGuardTape along jambs, providinga minimum 3" (75 mm) shin-gle lap of the StoGuardTape installed in Step 2.Then apply StoGuard Tapeto head of window openingand extending down ontojambs.
Step 4Construct shingle lap of Sto-Guard Fabric and StoGuardwaterproof air barrier coat-ing along top edge of Sto-Guard Tape.
Apply StoGuard waterproofair barrier membrane to wallsurface over StoGuard Tape.
Slope
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Flashing Integration at Window Opening - Box Window
Detail No.: 20.23a
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidSeal™B) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barrier)
C) StoGuard Fabric withStoGuard waterproof airbarrier membrane
D) StoGuard Tape (withStoGuard Fabricshingle lap)
2]Prepare opening prior to theinstallation of the window ormechanical equipment.Provide sill wedge or othermeans of positive slope toexterior at sill.
3]Prepare opening prior to theinstallation of the window ormechanical equipment.
4] Provide thermal break asneeded in pan flashingdesign, depending onclimate.
5] The complete installation ofwindow or mechanicalequipment should include anair seal between the objectand the StoGuard protectioninbound of the outer perime-ter weather seal.
6]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Structure (steel or wood)
Sheathing
StoGuard detailcomponent. See Details20.00a through 20.00efor rough openingprotection material andinstallation options.
StoGuard waterproof airbarrier membrane
Pan flashing with enddams (Note 4)
Sealant bead
Shingle-lap StoGuarddetail component overend-dam of sill panflashing. Detail requiressnug fit between enddam and jamb fortransition membraneoptions A), B), and C).Where gap exists orwhere gap is required toaccommodate thermalmovement of sill pan,provide transition withcove bead of compatiblepaintable wet sealantover backer (orcompatible low-expanding urethanespray foam), and applytransition membraneover sealant onto panend dam.
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Concealed Flashing at Sill - Nail Fin Window
Detail No.: 20.23b
EDG
E
1] StoGuard detail componentoptions:
A) StoGuard RapidSeal™B) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barriermembrane)
C) StoGuard Fabric withStoGuard waterproof airbarrier membrane
D) StoGuard Tape (withStoGuard Fabric shinglelap.)
2]StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Prepare opening prior to theinstallation of the window ormechanical equipment.
4] The complete installation ofwindow must include an airseal between the windowand the StoGuard protection,inbound of the outerperimeter weather seal.
5]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Structure (steel or wood)
Sheathing
StoGuard detailcomponent. See Details20.00a through 20.00efor rough openingprotection material andinstallation options.
StoGuard waterproof airbarrier membrane
StoGuard detailcomponent
Flashing with end dams
Air seal
Sealant bead Do notapply at bottom flange ofwindow.
Flanged (“Nail-fin”)window
(Optional) StoGuarddetail component lappedonto window flange alongjambs. Extend nominal1-inch (25 mm) minimumonto surface of wall.Do not apply to bottomflange of window.
Spacer
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
EDG
E
Window Head Flashing
Detail No.: 20.24a
1] StoGuard detail componentoptions:A) StoGuard RapidSeal™B) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barriermembrane)
C) StoGuard Fabric withStoGuard waterproof airbarrier membrane
D) StoGuard Tape (withStoGuard Fabric shinglelap)
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Prepare opening prior to theinstallation of the window ormechanical equipment.
4] The complete installation ofwindow must include an airseal between the window ormechanical equipment andthe StoGuard protection,inbound of the outerperimeter weather seal.
5]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Structure (steel or wood)
Sheathing
StoGuard detailcomponent. See Details20.00a through 20.00efor rough openingprotection material andinstallation options.
StoGuard waterproof airbarrier membrane
Flashing with end dams
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Head Flashing with Lintel
Detail No.: 20.24b
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) StoGuard RapidSeal™C) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barriermembrane)
D) StoGuard Tape (withStoGuard Fabric shinglelap)
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3]Prepare opening prior to theinstallation of the window ormechanical equipment.
4] The complete installation ofwindow must include an airseal between the window ormechanical equipment andthe StoGuard protection,inbound of the outer perime-ter weather seal.
5]Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier and slipsheet required behind porouscladdings not shown. Referto Sto Detail 20.00b foradditional information.
Structure (steel or wood)
Sheathing
Structural steel lintel
StoGuard detailcomponent (Note 1)
StoGuard detailcomponent. See Details20.00a through 20.00efor rough openingprotection material andinstallation options.
Flashing with end dams
StoGuard waterproof airbarrier membrane
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Balcony Floor to Wall Transition with Deck Coating
Detail No.: 20.30a
EDG
E
1]StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
2] Provide positive slope todirect water away from wall.Verify compatibility of water-proof deck membranematerials with StoGuardwaterproof air barriermembrane.
3] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Sheathing coated withStoGuard waterproof airbarrier membrane(Note 1)
Quarter-round backer rod
Compatible Sealant
Balcony slab
Compatible waterproofdeck coating. Extendminimum 4 inches (102mm) onto vertical surface
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Balcony Floor to Wall Transition - Inside and Outside Corners
Detail No.: 20.30b
EDG
E
1] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
2]Provide positive slope todirect water away from wall.Verify compatibility ofbalcony waterproofingmaterials with StoGuardwaterproof air barriermembrane
3] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Sheathing coated withStoGuard waterproof airbarrier membrane
Compatible sealant
Quarter-round backer rod
Compatible waterproofdeck coating. Extendminimum 4" (102 mm)onto vertical surface
Balcony slab
Framing (steel or wood)
Sheathing coated withStoGuard waterproof airbarrier membrane
Quarter-round backer rod
Compatible sealant
Compatible waterproofdeck coating. Extendminimum 4" (102 mm)onto vertical surface
Balcony slab
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Deck Connection
Detail No.: 20.32
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) StoGuard RapidSeal™C) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barriermembrane).
D) StoGuard Fabric withStoGuard waterproof airbarrier membrane
E) StoGuard Tape (withStoGuard Fabric shinglelap).
2]StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Sheathing coated withStoGuard waterproof airbarrier membrane
StoGuard detailcomponent
Flashing
StoGuard sheathing jointtreatment. See Sto Detail20.00a
StoGuard Tape
Deck flashing - end dam
Deck framing
Deck fasteners, set insealant.
Deck flashing - pan withdrip edge (supplementalflashing over deck ledgernot shown)
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Floor Line Flashing at Fixed Slab-to-Frame Condition
Detail No.: 20.51a
EDG
E
1] StoGuard detail componentoptions:
A) StoGuard RapidFillB) StoGuard RapidSeal™C) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barriermembrane)
D) StoGuard Fabric withStoGuard waterproof airbarrier membrane
E) StoGuard Tape (withStoGuard Fabric shinglelap)
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] StoGuard joint treatmentoptions:A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
4] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Framing
Sheathing coated withStoGuard waterproof airbarrier membrane
StoGuard detailcomponent
Flashing
StoGuard joint treatment(See Sto Detail 20.00a)
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Floor Line with Deflection Track
Detail No.: 20.51b
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) StoGuard RapidSeal™C) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barriermembrane)
D) StoGuard Fabric withStoGuard waterproof airbarrier membrane
E)StoGuard Tape (withStoGuard Fabric shinglelap)
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Framing
Sheathing coated withStoGuard waterproof airbarrier membrane
StoGuard detailcomponent
Flashing
Nested track (deflectiontrack)
StoGuard TransitionMembrane (Sto detail20.51TM)
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Shelf Angle at Floor Line
Detail No.: 20.51c
EDG
E
1] StoGuard detail componentoptions:A)StoGuard RapidFillB) StoGuard RapidSeal™C) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barriermembrane)
D) StoGuard Tape (withStoGuard Fabric shinglelap)
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Framing
Sheathing coated withStoGuard waterproof airbarrier membrane
StoGuard detailcomponent
StoGuard detailcomponent
Flashing
Shelf angle
Nested track (deflectiontrack)
StoGuard TransitionMembrane (Sto detail20.51TM)
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Vertical Through-Wall Expansion Joint with Wet Sealant
Detail No.: 20.52b
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) StoGuard RapidSeal™C) Sto Gold Fill StoGuard
Mesh top coated withStoGuard waterproof airbarrier membrane.
2]StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Specify a compatiblesealant material that meetsthe movement requirementsof the joint as defined by thejoint sealant supplier.
4] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Framing
Sheathing coated withStoGuard waterproof airbarrier membrane
Backer rod
StoGuard detailcomponent
Compatible sealant
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Inside Corner - Dissimilar Substrates(Fixed Frame Pilaster or Similar Condition)
Detail No.: 20.53
EDG
E
1] StoGuard joint treatmentoptions:
A) StoGuard RapidFillB) Sto Gold Fill® with
StoGuard Meshjoints < 1/8" (3 mm) wide
C) StoGuard Fabric withStoGuard waterproof airbarrier membranejoints < 1/8" (3 mm) wide
D) StoGuard RapidSeal™with StoGuard Mesh -joints < 1/4" (6 mm) wide
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
CMU Construction
Framing: steel or wood
Sheathing
StoGuard joint treatment
StoGuard waterproof airbarrier membrane
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Termination at Parapet
Detail No.: 20.60
EDG
E
1] StoGuard detail componentoptions:
A) StoGuard RapidFillB) StoGuard RapidSeal™
with StoGuard® MeshC) Sto Gold Fill® with
StoGuard Mesh (top coatedwith StoGuard waterproofair barrier membrane)
D) StoGuard Fabric withStoGuard waterproof airbarrier membrane
2] StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Verify compatibility of roofmembrane materials withStoGuard.
4]Verify continuity of roofmembrane to waterproof airbarrier interface.
5] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Refer toSto Detail 20.00b foradditional information.
Metal parapet cap
Blocking
Roofing membrane andair barrier
StoGuard detailcomponent
StoGuard waterproofair barrier membrane
Sheathing
Framing (wood orsteel)
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Saddle Wall Intersection
Detail No.: 22.64
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) StoGuard RapidSeal™
with StoGuard MeshC) Sto Gold Fill with
StoGuard Mesh topcoated with StoGuardwaterproof air barriermembrane.
2 StoGuard waterproof airbarrier membrane options:A) Sto EmeraldCoat®B) StoGuard VaporSeal™C) Sto AirSeal™D) Sto Gold Coat®
(Use with StoTherm NExTEIF systems)
3] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Sheathing
StoGuard detailcomponent
StoGuard waterproofair barrier membrane
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Mechanical Penetrations
Detail No.: 20.70
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) StoGuard RapidSeal™
with StoGuard MeshC) Sto Gold Fill® with
StoGuard Mesh(top coated with StoGuardwaterproof air barriermembrane)
D) StoGuard Fabric withStoGuard waterproof airbarrier membrane-(gaps < 1/8" [3 mm])
E) StoGuard Tape (withStoGuard Fabric shinglelap)
2]StoGuard waterproof airbarrier membrane options:A) Sto Gold Coat®
(vapor permeable)B) Sto EmeraldCoat®
(high perm)C) StoGuard VaporSeal™
(vapor impermeable)D) Sto AirSeal™
(high perm)
3] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slip sheetrequired behind somecladdings not shown. Referto Sto Detail 20.00b foradditional information.
Penetrations withgap < 1/4" (6mm)(see Note 1)
Sheathing
StoGuard detailcomponent
StoGuard waterproofair barrier membrane
Penetrations withgap > 1/4" (6 mm)[consult spray foammanufacturer formaximum size of gapfor product beingused)
Low expandingurethane spray foamto fill wide gap
Cured spray foamtrimmed flush withsheathing
StoGuard detailcomponent
StoGuard waterproofair barrier membrane
R
www.stocorp.com
Date: March 2014
Notes:
StoGuard® Waterproof Air BarrierFrame Construction
Property of Sto Corp. All Rights Reserved.
Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional,general contractor or builder. They should be installed in accordance with those specifications and Sto‘s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections,for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building compo-nents or assemblies, or for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or build-ing may result in serious damage to Sto products, and to the structure of the building or its components. STO CORP. DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED EXCEPTFOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO‘S WARRANTY PROGRAMS WHICH ARE SUB-JECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers,please refer to the Sto Corp. website, www.stocorp.com.
Attention
IMPORTANT: Components not identifiedas Sto are furnished by other manufactur-ers and are not necessarily installed bytrades who install the Sto products. Referto project specific contract documents.
Scupper
Detail No.: 20.75
EDG
E
1] StoGuard detail componentoptions:A) StoGuard RapidFillB) StoGuard RapidSeal™
with StoGuard MeshC) Sto Gold Fill® with
StoGuard Mesh (topcoated with StoGuardwaterproof air barriermembrane)
D) StoGuard Fabric withStoGuard waterproof airbarrier membrane-(gaps < 1/8" [3 mm])
E) StoGuard Tape (withStoGuard Fabric shinglelap)
2]Prepare opening prior to theinstallation of the window ormechanical equipment.Provide sill wedge or othermeans of positive slope toexterior at sill.
3] Verify compatibility of roofmembrane materials withStoGuard.
4] Verify continuity of roofmembrane to waterproof airbarrier interface.
5] Refer to Sto specificationsand product bulletins fordetailed information onsubstrates and Sto materialoptions. Additional water-resistive barrier/slipsheet required behind somecladdings not shown. Refer toSto Detail 20.00b foradditional information.
Framed parapetassembly (wood orsteel frame)
StoGuard detailcomponent (lapnominal 1-inch ontoscupper assembly)(Note 1)
Scupper assembly
Roofing membrane
StoGuard waterproofair barrier membrane