At Siemens Water Technologies, our mission is to
provide products and services to meet your water
treatment needs, any time, any place. As one of
the world’s largest water treatment companies,
we offer a wide range of products and services,
combined with experience and technical
knowledge you can trust. We will deliver a
solution that meets even the most stringent
specifications. And, because your satisfaction is
important to us, we stand behind the quality of
our products and services.
Table of Contents
PRODUCT QUICK REFERENCE GUIDE BY INDUSTRY . . . . . . . . . . . . . . . . . . 2
WATER TREATMENT TECHNOLOGIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
WASTEWATER CAPABILITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
SUPPORT SERVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
WATER QUALITY STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
TRADEMARK STATEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
For a detailed table of contents, refer to each section’s table of contents.
S
U
M
M
A
R
Y
W A T E R
P U R I F I C A T I O N
P R O D U C T S
A N D S E R V I C E S
C A T A L O G
1
BACK
2 PRODUCT QUICK REFERENCE GUIDE BY INDUSTRY
Siemens Water Technologies24-hr Customer Service: 800.466.7873
BACK Main Table of Contents
Use this table only as a guideline. Products may be used in other industries depending on your specifications.
ACTIVATED CARBON FILTERS
CT Series Carbon Towers l l l l
HOT Series Systems l l l l
KF Series l l l l l l l
VP Series l l l l l l
Mobile l l l l l l l l l l
CHEMICAL FEEDSYSTEMS l l l l l l l l l l l l
CLARIFIERSPackage Precipitators l l l l l l l l l
DEAERATORSSLH Deaerating Heaters l l l l l l l
DG Series Forced Draft Decarbonators l l l l l l l l l l l
DEIONIZATION
CDI-LX™ Systems l l l l l l l l l l
CDI-LX™ Low Profile Kits l l l l l l l l l l
Deionization RecirculatingSystems (DIRS) l l l l l l l l l l l l l l
VP Series Two Beds l l l l l l
VP Series Mixed Beds l l l l l l
Mobile l l l l l l l l
C O N S U LT T H E S E G U I D E L I N E S TO F I N D S I E M E N S WAT E R T E C H N O L O G I E S P R O D U C T S A N D S Y S T E M S F O R Y O U R I N D U S T RY.I N D U S T R I E S A R E L I S T E D AT T H E TO P.
3PRODUCT QUICK REFERENCE GUIDE BY INDUSTRY
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
BACK Main Table of Contents
Use this table only as a guideline. Products may be used in other industries depending on your specifications.
SERVICE DEIONIZATION (SDI)Tanks, Deionizers, Carbon and Resin l l l l l l l l l l l l l l
WATER SYSTEMS INTEGRATED
EPV™ Systems l l l l l
PreVUE® Systems l l
APEX™ Systems l l
MULTIMEDIAFILTERSAVGF Gravity Filters l l l l l l l l l l
KF Series l l l l l l l
VP Series l l l l l l
Mobile l l l l l l l l l l
RO SYSTEMSMicRo Series l l l l l l l
40 Series l l l l l l l
Pharm40 Series l l
BevMAX™ l
Vantage™ M21, 41, 43 l l l l l l
Vantage™ M83, M84 l l l l l l l l l l
Vantage™ M240 l l l l l l
Vantage™ M280 l l l l l l l l l
C O N S U LT T H E S E G U I D E L I N E S TO F I N D S I E M E N S WAT E R T E C H N O L O G I E S P R O D U C T S A N D S Y S T E M S F O R Y O U R I N D U S T RY.I N D U S T R I E S A R E L I S T E D AT T H E TO P.
4 PRODUCT QUICK REFERENCE GUIDE BY INDUSTRY
Siemens Water Technologies24-hr Customer Service: 800.466.7873
BACK Main Table of Contents
(continued from page 3)
C O N S U LT T H E S E G U I D E L I N E S TO F I N D S I E M E N S WAT E R T E C H N O L O G I E S P R O D U C T S A N D S Y S T E M S F O R Y O U R I N D U S T RY.I N D U S T R I E S A R E L I S T E D AT T H E TO P.
LABORATORY PRODUCTS
Use this table only as a guideline. Products may be used in other industries depending on your specifications.
MEDICAL RO (DIALYSIS)Med-RO® RX Series l l
SOFTENERSKF Series l l l l l l l
VP Series l l l l l l
PURELAB® Ultra l l l l l l l l
PURELAB® Classic l l l l l l l
PURELAB® UHQ Water Purification Systems l l l l l l l
PURELAB®Option Water Purifiers l l l l l l
MEDICA® l
MEDICA® Pro l l
REVERSE OSMOSIS SYSTEMSPURELAB® Prima l l l l l l l
CENTRA® (HF) l l l l l l l
MODULAB® (HF) l l l l l l
Water Treatment Technologies
T A B L E O F
C O N T E N T S
Removal of Common Contaminants Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Activated Carbon Filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chemical Addition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Clarification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Continuous Electrodeionization (CEDI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Dealkalization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Degasification/Deaeration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Deionization (DI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Distillation for WFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Reverse Osmosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
S3™ Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Sanitization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Softening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Ultraviolet Sterilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5
BACK Main Table of Contents
6
Removal of Common Contaminants
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
COMMON CONTAMINANTS C
Alkalinity Carbon Calcium, Chlorine, InorganicsDioxide Magnesium Chloramines (dissolved) o
Activated Carbon Filtration l
Chemical Addition l l l l l l
Clarification
Continuous Electrodeionization (CEDI) l l l l l l l
Dealkalization l
Degasification/Deaeration l
Deionization l l l l l l l
Distillation l l l l l l l l l l
Filtration
Reverse Osmosis (RO) l l l
Sanitization
Softening l l
Ultraviolet Sterilization l
TECHNOLOGY
7
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
COMMON CONTAMINANTS
Iron Microbiologicals Organics Particles Pyrogens Silica Description(dissolved) of Technology
l 8
l l 8
l 8
l l l 9
9
10
l l l 10
l l l l l l 11
l 12
l l l l l l 14
l l l 14
l 15
l l 15
Removal of Contaminants is based on the proper use of equipment in the appropriate treatment train. Products are combined to form the best solution for you. Use this table only as a guide.
8 WATER TREATMENT TECHNOLOGIES
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
ACTIVATED CARBON FILTRATIONActivated carbon is carbon that has been processed at high temperature to form
a material with high adsorptive capacity. Usually available in a granular or
powdered form, activated carbon is used to remove chlorine, chloramines and
dissolved organics from water. Carbon filters are frequently used as pretreatment
to membrane and ion exchange-based systems that can be damaged by oxidants
such as chlorine. Two types of activated carbon media:
• High-capacity granular carbon for chlorine removal.
• Organic reduction carbon that uses bituminous coal activated at high
temperature for adsorption of both high and low molecular weight organics.
There are several different types of activated carbon filters available, including
service carbon, backwashable carbon and steam or hot-water-sanitizable carbon.
CHEMICAL ADDITION Chemicals are often added during or after industrial and municipal water
treatment to enhance the treatment process or further treat the water to meet
specific customer requirements.
The water’s pH is sometimes adjusted to meet the operating specifications
required by certain membranes or ion exchange resins. This is accomplished by
adding caustic soda to raise the pH, or acid to reduce the pH. Dispersants or
antiscalants are sometimes added to prevent scaling from a concentration of
specific ions in the water. Oxidizing agents, sequestering (chelating) agents and
reducing agents can also be added to the water. Oxidizing agents are used to
prevent microbial growth. Sequestering agents help prevent hardness minerals,
such as calcium and magnesium, from depositing on the surface of water
systems, system piping and tanks. Reducing agents, such as sodium
metabisulfite, are added to neutralize oxidizing agents, such as ozone or chlorine,
or remove oxygen.
CLARIFICATIONClarification is a multi-step process that reduces turbidity and suspended matter. It
also reduces iron and removes color, taste and odor in the water by adding oxidizing
agents, such as chlorine. Clarification consists of three steps: coagulation,
flocculation and sedimentation. During the coagulation stage, chemical coagulants
or pH-adjustment chemicals are used to destabilize the particles. During the
flocculation stage, other chemicals are added to take the previously destabilized
particles and make them stick together. They become agglomerated and form a floc.
During sedimentation, the floc settles by gravity and separates from the water.
9
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Continuous ElectrodeionizationSiemens CDI® System
Feed Water NaCl ¶
¹º
¸ ¸·
Product Water H2O
¼
Waste Stream (NaCl) Concentrate
Ï
Cl–
Na+Na+
OH–
( – )Cathode
( + )Anode
H+
Cl–
¶¶
CONTINUOUS ELECTRODEIONIZATION (CEDI)
Continuous Electro Deionization (CEDI) is a continuous process for producing
high-purity water without the problems and costs associated with regeneration
chemicals and waste neutralization. It is used to further deionize RO product
water and remove carbon dioxide, silica and total organic carbon (TOC). CEDI
systems use ion exchange membranes, ion exchange resins and electricity to
produce consistent high-quality water with no regeneration downtime. When
fed with RO product water, CEDI systems achieve better than 99.5% salt
removal and produce up to 18.2 mΩ-cm (0.055 micromho/cm) resistivity
quality water.
How a CEDI system works:
¶ Feedwater entering the system flows inside resin/membrane product and
concentrate compartments. The feed stream flows parallel to the membrane
surface.
Ë Resins capture dissolved ions.
Ì Electric potential drives captured cations through the cation membranes and
captured anions through the anion membranes.
Í Cation-permeable membranes transport cations out of the diluting
compartment, but prevent anions from leaving the concentrate
compartment.
Î Anion-permeable membranes transport anions out of diluting compartment,
but prevent cations from leaving the concentrate compartment.
Ï Waste stream removes concentrated ions from the system.
Ð Product water leaves the system.
DEALKALIZATIONDealkalizers remove alkalinity from feedwater for process, boiler feed (low-
pressure boilers) and cooling-tower applications. Chloride cycle dealkalizers use
strong-base anion ion exchange resins that are regenerated with salt to remove
bicarbonate, carbonate, sulphate and nitrate ions from high alkalinity waters by
exchanging them for chloride ions. Split stream dealkalizers “split” the feedwater,
so a portion goes to the hydrogen-form cation resin unit, converting all alkalinity
to carbon dioxide, and the other portion to the sodium-form cation resin unit
(softening). The effluents of both units are then re-joined to produce dealkalized
water.
WATER TREATMENT TECHNOLOGIES
10 WATER TREATMENT TECHNOLOGIES
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
DEGASIFICATION/DEAERATIONDegasification, or gas stripping, removes undesirable dissolved gases, such as
oxygen, carbon dioxide, ammonia and hydrogen sulfide from water. The gases are
removed by exposing the water to a vapor phase that is missing the gases to be
eliminated. Degasification equipment is classified as ebullition, tray or drip and
spray type units.
One type of drip degasifer is the forced draft degasifer, which removes dissolved
gases from water without changing its ambient temperature. Forced draft
degasifiers are particularly useful for eliminating carbon dioxide formed by the
acid used to adjust raw water alkalinity prior to reverse osmosis treatment. They
also reduce hydrogen sulfide and other dissolved gases in water, and may be
used to oxidize dissolved iron and manganese for subsequent removal by a filter
or clarifier. In this type of operation, they are commonly referred to as aeration
units since they add oxygen to the water for oxidation.
DEIONIZATIONDeionization removes dissolved minerals and salts, as well as some dissolved organics,
from water using the process of ion exchange. During ion exchange, certain ions of a
given charge are replaced (or exchanged) with different ions of the same charge.
These replacement ions are provided by ion exchange resins.
Positively charged ions in the water (cations), such as calcium, magnesium and
sodium are removed by cation exchange resins and replaced with hydrogen ions.
Negatively charged ions (anions), such as chloride, nitrate and sulfate are removed
by anion exchange resins and replaced with hydroxide ions. The hydrogen and
hydroxide ions then unite to form water molecules.
Deionization is conducted in pressure vessels containing the ion exchange resins.
Typical deionization systems consist of separate cation and anion vessels connected
in series (called a separate bed or two bed). These systems produce water up to 1
megohm-cm quality. For higher purity water, a single vessel containing a mixture of
cation and anion resins (called a mixed bed) is employed. Mixed bed deionizers can
produce water up to 18 megohm-cm quality.
11WATER TREATMENT TECHNOLOGIES
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Service DeionizationService deionization (SDI) refers to portable deionization equipment that is designed
for off-site regeneration. A SDI system typically consists of a prefilter, activated
carbon and deionization (DI) tanks, interconnecting hoses, pressure gauges, a
pressure regulator and quality indicators. SDI systems may include separate bed
tanks, mixed bed tanks or a combination of the two, depending on the product
water quality requirements.
When the resins in the tanks reach exhaustion (are no longer capable of effective
ion exchange), the tanks are disconnected and replaced with tanks containing
freshly regenerated resins. The tanks containing the exhausted resin are transported
to a regeneration facility. With SDI, the customer does not make a major capital
investment, and does not handle hazardous regeneration chemicals (acids and
caustics).
Automatic DeionizationDeionizers that are regenerated at the customer site are referred to as automatic
deionizers (Auto DI). During regeneration, the cation resin is treated with acid,
usually hydrochloric acid, and the anion resin is treated with caustic. Automatic
deionizers contain the necessary piping, valves and controls, water quality monitors
and alarms to regenerate the system when required.
DISTILLATION FOR WFIDistillation is a process whereby feedwater is vaporized at a pressure slightly
above atmospheric, leaving non-volatile impurities behind. The vapor passes
through a separator where heavier particles are raised. The vapor is then
compressed to a higher temperature and pressure. This high temperature vapor
transfers its latent heat to the feedwater as it condenses (leaving non-
condensables behind). Degassing of the distillate further increases the purity of
the water. The steam heats the water in the evaporators and the extra heat is
then recovered. Vapor compression distillation is often used in purified water
production to produce hot distillate in systems where the water is stored and
distributed at an elevated temperature (176˚F/80°C). Distillation removes salts,
colloids, particles, bacteria and pyrogens from water down to 10 parts per trillion
(ppt). It is used for producing Water for Injection (WFI) and USP Purified Water.
12 WATER TREATMENT TECHNOLOGIES
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
FILTRATION
Filtration removes solid matter and suspended impurities from a fluid stream by
passing it through a variety of devices, including microporous filters (which
include depth, screen and surface filters), ultrafiltration units, greensand,
activated carbon, diatomaceous earth and multimedia filters. Microporous filters
remove particles according to the filter’s pore size. They are often used before
other water purification equipment, such as deionization and reverse osmosis
systems, and are also used as polishing filters to remove resin and carbon fines,
colloids and microorganisms.
MicrofiltrationMicrofiltration, also known as surface, membrane, screen and absolute filtration,
uses microporous filters to remove particles and bacteria in the approximate
range of 0.05 to 10 microns. Microporous filter ratings correspond to the largest
hole or pore in the filter material matrix, which means anything larger will be
“absolutely” removed. Microporous filters are often used as “polishing” filters to
remove contaminants that were not removed by depth filtration.
Multimedia FiltrationMultimedia filters offer a highly efficient means of removing suspended
particulate matter from water. The three layers of media are selected for their
particular size, specific gravity and ability to trap particles of specific size ranges.
As water flows downward through the bed, it encounters layers of media with
decreasing porosity, so successively smaller particles are trapped in each layer,
providing true depth filtration. The filters provide high clarity water either for
direct use or for pretreatment to softeners, deionizers or reverse osmosis
systems.
Depth Filtration
Surface Filtration
13WATER TREATMENT TECHNOLOGIES
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
NanofiltrationNanofiltration is a crossflow-membrane separation process that removes selected
salts, most organics and particles in the 300 to 1,000 molecular weight range.
Nanofiltration softens the water without the need for salt regeneration.
UltrafiltrationUltrafiltration uses membranes to retain undissolved and dissolved contaminants
that are larger than the nominal molecular weight cutoff rating (NMWC) of the
membrane (typically 5,000 to 500,000 daltons). Ultrafiltration removes particles,
colloidal silica, microorganisms and pyrogens.
REVERSE OSMOSISThe natural process of osmosis occurs when solutions with different
concentrations of salts are separated by a semi-permeable membrane. As
osmotic pressure drives water through the membrane, the water dilutes the more
concentrated solution until equilibrium is achieved. Reverse osmosis (RO) uses
external pressure to reverse the process of osmosis. The water is forced by this
external pressure through a semi-permeable membrane from a more
concentrated solution to a less concentrated one. The RO membrane allows the
water to pass through while retaining (or holding back) a large percentage of the
dissolved inorganics, organics, bacteria and pyrogens. The pure water collected
on the downstream side of the membrane is called the permeate or product
water. RO membranes remove 99% of the feedwater particles, colloids, bacteria,
pyrogens and organics greater than 200-300 molecular weight (MW) range, or
larger than the membrane’s pore size of 150 to 200 Ångströms. It removes 90-
99% of dissolved inorganics. The greater the ionic charge of the inorganic
contaminants, the more likely they will be removed by the RO membrane.
Membrane
Osmosis
Osmotic Pressure
PressureReverse Osmosis
RO Membrane
14 WATER TREATMENT TECHNOLOGIES
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
S3™ SYSTEMS3™ system is a patent-pending technology developed by Siemens Water
Technologies for high-purity water applications. S3™ technology is used to
produce purified water, non-compendial water or still feed water. The
technology improves upon proven active sanitization methods with a unique,
start/stop mode of operation. Conventional systems require continuous water
recirculation for microbial control, thereby wasting significant energy, water and
consumables. The Siemens’ S3™ process implements periodic short, high
temperature heat cycles of up to 80˚C prior to startup for water production. The
high temperature hold period is typically 5 minutes or less. The shortened heat
cycles result in water conservation and energy reduction when compared with
continuous recirculation methods. The water and energy cost savings often
significantly exceed the system capital cost over the lifetime of the system.
SANITIZATIONWater purification systems and filters can become contaminated by bacteria that
grow inside them. Although most water systems remove the majority of organic
material from the feedwater, gram negative bacteria are able to survive and
multiply in water that contains only small amounts of organic matter. The
bacteria eventually form a layer of biofilm on the water system surfaces, and this
biofilm continuously releases microbes into the water. Bacteria also forms
pyrogens that may elevate organic levels in the product water. For this reason,
proper sanitization of water systems is essential for optimum performance. The
frequency of sanitization and the method used depends on your specific
application.
Sanitization can be done either continuously or periodically with shock
treatments. Continuous sanitization keeps bacteria growth from recurring, while
shock treatments remove bacteria but do not prevent it from recurring.
Continuous sanitization is typically used when a constant level of sanitant is not
harmful to the end-user production process. Shock treatments usually involve
shutting down the production process, introducing sanitant into the system and
then flushing the sanitant from the system before it is placed back on-line.
Often, the water purification system must be cleaned before it can be sanitized.
Cleaning removes the biofilm from equipment surfaces, resulting in more effective
sanitization. Some common chemical sanitants are chlorine (liquid and gas),
chloramines, chlorine dioxide (ClO2), hydrogen peroxide (H2O2), peracetic acid
(CH3COOOH), ozone (O3) and formaldehyde (HCHO). Physical treatments include
heat and ultraviolet (UV) light.
15WATER TREATMENT TECHNOLOGIES
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SOFTENINGSoftening removes hardness minerals, such as calcium and magnesium from
water. Water softeners are commonly used as pretreatment for boiler feed make-
up water systems to prevent calcium and magnesium scale formation in boilers.
They are also used to remove dissolved iron from water.
Ion exchange water softening replaces or exchanges the calcium and
magnesium cations with an equivalent number of sodium cations.
Hot process softening removes hardness by heating the water to near boiling,
followed by the introduction of softening chemicals, such as hydrated lime and
soda ash. The minerals then precipitate and settle toward the bottom of the tank,
forming a sludge blanket. As the treated water flows through the sludge blanket,
most of the turbidity is trapped and removed. The effluent is then passed
through filters that remove the last trace of suspended matter.
Cold lime softening is similar to hot process softening, except the water is not
heated before lime is introduced into the system. This process is carried out in a
specially designed clarifier.
Softeners can be regenerated co-current (downflow) or counter-current
(counterflow). Co-current is when the regenerant chemical and service flows are
in the same direction.
Counter-current is when the service and regeneration chemical flows are in the
opposite direction. Counter-current operations provide lower hardness leakage
when operated properly.
ULTRAVIOLET STERILIZATIONUltraviolet (UV) sterilization is used as a pretreatment and/or post-treatment step
to kill or inhibit growth of microorganisms, remove ozone, chlorine and trace
organics and reduce total organic carbon (TOC). In UV sterilization, the water is
exposed, at a controlled rate, to ultraviolet light waves. Ultraviolet is the band of
light located in the spectrum between 2000 and 3000 Ångström wavelengths.
The most effective range for destroying bacteria is at 2537 Ångström (254
nanometers). The bacteria absorb the UV radiation energy, which destroys or
inactivates their DNA, thus preventing the bacteria from reproducing. UV systems
may reduce 99% of bacteria in the water.
Water Softening
Ca+Mg+
Cation Resin
Na+
Brine Tank
Section Table of ContentsBACK Main Table of ContentsBACK
Products
T A B L E O F
C O N T E N T S
17
BACK
ACTIVATED CARBON FILTERSKF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20VP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22HOT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
ACTIVATED CARBON MEDIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24ANALYTICAL ANALYZERS, TEST KITS, SAMPLING DEVICESAnalyzers
Silica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Chlorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Hardness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Dissolved Solids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Hydrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Microbiological Analysis Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . 25Portable TOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Test KitsFouling Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Alkalinity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Carbon Dioxide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Chlorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Hardness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Iron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Silica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26RO Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Sampling DevicesBacteria Samplers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27ESP Sanitary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
BAG FILTERSFilter Bags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
CARTRIDGE FILTERSCartridge End Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Activated Carbon FiltersGranular Activated Carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Pulverized Activated Carbon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Particulate CartridgesDI Gard™ String Wound. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35ROGARD™ Graded Density Polypropylene . . . . . . . . . . . . . . . . . . . 36Prepure DP™ Graded Density Polypropylene Depth . . . . . . . . . . . . . 37NT Series Graded Pore Polypropylene Depth. . . . . . . . . . . . . . . . . . . 38Postpure PP™ Graded Density Pleated Polypropylene Depth . . . . . 39NA Series Absolute Rated Polypropylene Depth. . . . . . . . . . . . . . . . . 40WN Series Pleated Polysulfone Membrane. . . . . . . . . . . . . . . . . . . . . 41
Main Table of Contents
18
BACK
DEAERATORSPermutit® SLH Dearating Heaters. . . . . . . . . . . . . . . . . . . . . . . . . . 85
DEGASIFIERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86DEIONIZATION
Recirculating Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87VP Series Two Bed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88VP Series Mixed Bed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89VP Series Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
DIALYSIS (HEMODIALYSIS)Bicarbonate Mixing System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Med-RO® Reverse Osmosis Medical System – RX Series . . . . . . . . 92
GAUGESPressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
HIGH PURITY WATER SYSTEMSPureFit® High Purity Water Treatment Systems . . . . . . . . . . . . . . . . 96
ION EXCHANGE RESINS AND FILTER MEDIAUSF™ Ion Exchange Resins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98Filter Media and Activated Carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . 99Resin Cross Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
ION EXCHANGE WASTEWATER SYSTEMS . . . . . . . . . . . . . . . . . . . 102Aquasaver Chemical Feed And Pump Skid. . . . . . . . . . . . . . . . . . . . 103
LABORATORY WATER PURIFICATION SYSTEMSUltrapure Water Systems
PURELAB® Ultra Water Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 104PURELAB® Classic Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106PURELAB® UHQ Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108MODULAB® High Flow Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
General Grade Water SystemsPURELAB® Option-S 7/15/30/60 Water Systems . . . . . . . . . . . . . . 110PURELAB® Option-R 7/15/30/60 Systems . . . . . . . . . . . . . . . . . . . 112PURELAB® Option-Q 7/15 Systems . . . . . . . . . . . . . . . . . . . . . . . . 114
Primary Grade Water SystemsPURELAB® Prima 7/15/20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116PURELAB® Prima 30/60/90/120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118Centra Packaged Central Water Systems . . . . . . . . . . . . . . . . . . . . . 120
Medica Water Systems for Clinical AnalyzersMEDICA® S/R/D 7/15 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122MEDICA® Pro 30/60/120 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . 124MEDICA® R-200 (High Volume) Systems . . . . . . . . . . . . . . . . . . . . 126
Deionization SystemsPortable Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Disposable Deionization System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129Recirculating Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Modular Docking Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131Storage Reservoirs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132Accessories
Carboys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133Faucets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Products, continued
WE Series Pleated Polysulfone Membrane . . . . . . . . . . . . . . . . . . . . 42
DI Series Pleated Hydrophilic PVDF Media . . . . . . . . . . . . . . . . . . . . 43
PV Series Pleated Hydrophilic PVDF Media . . . . . . . . . . . . . . . . . . . . 44
VH Series Pleated PES Media Pharmaceutical Grade. . . . . . . . . . . . 45
UF Series Hollow Fiber Polysulfone Media . . . . . . . . . . . . . . . . . . . . . 46
Housings
316 Stainless Steel, Single Tube (Code F) . . . . . . . . . . . . . . . . . . . . . 47
316L Stainless Steel, Single Tube (Code O) . . . . . . . . . . . . . . . . . . . . 48
316L Electropolished Stainless Steel, Multi-tube. . . . . . . . . . . . . . . . . 49
316L Stainless Steel, Multi-tube (High-Purity) . . . . . . . . . . . . . . . . . . . 50
316 Stainless Steel, Multi-tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
304 Stainless Steel, Multi-tube (with V Clamp closure). . . . . . . . . . . . 53
304 Stainless Steel, Multi-tube (with Swing Bolt closure). . . . . . . . . . . . 54
Polypropylene Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
White Polypropylene Plastic (Dialysis) . . . . . . . . . . . . . . . . . . . . . . . . . 56
Natural Polypropylene Plastic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Speciality Cartridges
CLERIFY™ Oil Adsorption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Vent Filter Cartridges
Hydrophobic PTFE Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
EA Series Hydrophobic Polypropylene Media . . . . . . . . . . . . . . . . . . . 60
VA Series Hydrophobic PTFE Media . . . . . . . . . . . . . . . . . . . . . . . . . . 61
VP Series Hydrophobic PTFE Media . . . . . . . . . . . . . . . . . . . . . . . . . . 62CHEMICAL FEED SYSTEMS AND ACCESSORIES
Pre-Kitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Dual Pump Skidded - Grundfos . . . . . . . . . . . . . . . . . . . . . . . . . . 64Dual Pump Skidded - LMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Polymer Feed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Metering PumpsChem-Tech® Metering Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . 67LMI® Metering Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Pulsatron® Metering Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Pulsatron® Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Chem-Ad® LX Diaphram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Encore® 700 Diaphram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Chemtube® PPS Peristaltic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Instrumentation & Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Storage and Bulk Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79CLARIFIERS
Permutit® Package Precipitators . . . . . . . . . . . . . . . . . . . . . . . . . . 80CLEAN-IN-PLACE SKIDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81CONTINUOUS DEIONIZATION SYSTEMS
CDI-LX™ Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82CDI® Replacement Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
CONTROL PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Main Table of Contents
19
BACK
Products, continued
TOTAL-CHECK™ 900 total organic carbon Monitor . . . . . . . . . . . . . 135Remote Control Stations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Remote Dispense Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Point-of-Use Capsule Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138IWT® Filtration Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139Replacement Cartridges
Siemens, USFilter®, ELGA® Lab Water Systems . . . . . . . . . . . . . . 140Millipore® Lab Water Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144Barnstead® Lab Water Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
LEAK DETECTORSDI-SDI ALERT® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149WLD Model 300A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
LIGHTS, QUALITY INDICATOR5-Range Purity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151Hy-Lite Water Quality Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
LIQUID LEVEL CONTROLSTank Level Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
METERSConductivity & Resistivity Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Total Organic Carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
MULTIMEDIA FILTERSAVGF® Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156KF Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157VP Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
PUMPS, CENTRIFUGALMultiple Stage Centrifugal/Victaulic Booster . . . . . . . . . . . . . . . . . . . 159Multiple Stage Centrifugal/ANSI Flange Booster. . . . . . . . . . . . . . . . 160Feedwater Booster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
REVERSE OSMOSIS MEMBRANESReplacement Membranes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162Siemens Proprietary Membranes for Obsolete Systems . . . . . . . . . 163
REVERSE OSMOSIS SYSTEMSVantage™ MicRo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164Vantage™ M21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165Vantage™ M41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166Vantage™ M43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169Vantage™ M83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170Vantage™ M84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171Pharm 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17640 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177Vantage M240 Two Pass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178Vantage M280 Two Pass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179BevMAX™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
SERVICE DEIONIZATION (SDI)SDI Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
SOFTENERSKF Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185KF Series Twin Alternating Softeners. . . . . . . . . . . . . . . . . . . . . . . . . 186KF Series Duplex Alternating Softeners. . . . . . . . . . . . . . . . . . . . . . . 187
VP Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188STORAGE TANKS
Polyethylene, Conical Bottom. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190Fiberglass, Dish-Bottom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191Polyethylene, Flat Bottom. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192TerraPure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
SYSTEM, EPV™ VALIDATABLE SKIDDEDEPV™ Validatable Skidded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
SYSTEM, PreVUE® AND APEX™ VALIDATED SKIDDEDPreVUE® Validated Skidded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196APEX™ Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
TEMPORARY MOBILE WATER TREATMENTMobile Demineralization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199Mobile Clarification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200Mobile Reverse Osmosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201PreFlex® Skid-Mounted Pretreatment Systems . . . . . . . . . . . . . . . . 202FlexTrex® Skid-Mounted Deionization Systems . . . . . . . . . . . . . . . . 203FlexRO® Skid-Mounted RO Systems . . . . . . . . . . . . . . . . . . . . . . . . 204
ULTRAVIOLET STERILIZERSZCS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205ZHX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206ZCT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207Replacement UV Monitoring for Aquafine® Series UV . . . . . . . . . . . 208Ultraviolet Light Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
VALVES/REGULATORSBlend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211Pressure Relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
WASTEWATER CAPABILITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212SUPPORT SERVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215WATER QUALITY STANDARDS AND CONVERSIONS . . . . . . . . . . . 231GLOSSARY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246TRADEMARK STATEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Main Table of Contents
20 ACTIVATED CARBON FILTERS
KF Series Carbon FiltersFlow Rates from 1 to 81 gpm
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
KF Series Carbon Filters are ideal for commercial and light industrial filtration
applications where the advantages of a lightweight, corrosive-resistant FRP
pressure vessel and cost-effective top mounted valve are desirable.
• For pharmaceutical, cosmetic, microelectronic, boiler feed, process water,
laboratory applications and more
• Tanks are blow-molded plastic, wrapped with high-strength fiberglass and
contain epoxy resin for worry-free service
• Dependable motorized control valve is included with each filter
• Electromechanical timer allows automatic backwash
• Pretreatment lock-out switch assembly is included to deactivate downstream
equipment during backwash
SYSTEM SPECIFICATIONS
Chlorine Organics
Tank Size Pipe Commercial* RO-Feed** Commercial* RO-Feed** Backwash Media Overall Shipping(D x H in) Size Service Service Service Service Flow Vol Dimensions Weight
(in) Flow Flow Flow Flow (ft3) LxDxH (in) lb (kg)
10x40 1.0 3 gpm 2 gpm 1 gpm 1 gpm 5 gpm 1.0 10x10x50 100 (46)12x52 1.0, 1.5 6 gpm 4 gpm 2 gpm 2 gpm 8 gpm 2.0 12x12x63 140 (64)
14x65 1.0, 1.5 9 gpm 6 gpm 3 gpm 3 gpm 10 gpm 3.0 14x14x76 210 (96)
16x65 1.0, 1.5 12 gpm 8 gpm 4 gpm 4 gpm 14 gpm 4.0 16x16x76 310 (141)
18x65 1.0, 1.5 15 gpm 10 gpm 5 gpm 5 gpm 18 gpm 5.0 18x18x76 400 (182)
21x62 1.5, 2.0 18 gpm 12 gpm 6 gpm 6 gpm 24 gpm 6.0 21x21x74 530 (241)
24x72 2.0 24 gpm 16 gpm 8 gpm 8 gpm 30 gpm 8.0 24x24x90 1190 (540)
30x72 2.0 45 gpm 30 gpm 15 gpm 15 gpm 50 gpm 15.0 30x30x96 1530 (694)
36x72 2.0 60 gpm 40 gpm 20 gpm 20 gpm 70 gpm 20.0 36x36x97 1943 (882)
42x72 3.0 81 gpm 54 gpm 21 gpm 27 gpm 90 gpm 27.0 42x42x110 2000 (907)Electrical Requirements . . . . . . . . . . . 110 V/1 ph/60 Hz – 10 watts
*Flow is based on 3.0 gpm/ft3 for chlorine removal. Flow is based on 1 gpm/ft3 for organic reduction.**Dechlorination flow is based on 2 gpm/ft3, and assumes inlet Cl2 < 3 ppm; outlet Cl2 ≤ 0.1 ppm; inlet turbidity < 5 NTU. Organic reduction flow isbased on 1 gpm/ft3, and assumes inlet TOC ≤ 5 ppm as O2 consumed; inlet turbidity < 5 NTU.
ORDERING INFORMATION
Catalog Number: KFZCS XXX F X Z F X X
System Name . . . . . . . . . . . . . . . KFZCS 010, 012, 014,016, 018, 021,
Pressure Vessel Diameter (in inches). . . . . . . 024, 030, 036, 042Pressure Vessel Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F = non-code, fiberglassControl Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X = NEMA3R equivalent A = 1"Level of Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z = Stand alone B = 1.5"Backwash/Regeneration Initiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F = Timeclock, NEMA 3R equivalent C = 2"Inlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E = 3" X = No Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Option
To determine your catalog order number, replace the X with one of the numbered options below it.These filters are also available as duplex units. Please contact our Technical Support team for more information.†All sizes are not available with every tank size. In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Requires fieldassembly
21ACTIVATED CARBON FILTERS
VP Series Carbon FiltersFlow Rates from 8 to 300 gpm
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
VP Series Carbon Filters are a low cost, reliable and efficient way to purify water.
These rugged, pre-engineered, pre-assembled units minimize installation and start-
up costs and are ideal for boiler feed, process water or rinse water applications.
• VPEC denotes Non-ASME code vessels offered with express delivery
• VPAC denotes ASME code vessel with stamp available
• Simple design maximizes reliability and efficiency
• 100 psig vessel rating offers added strength and integrity
• Structural steel (seismic zone 4) legs provide rigid support of vessel for safety
• Skid mounting with (seismic zone 4) structural steel beams for duplex systems
• Backwash and regeneration controls are highly reliable
• Optional metallic piping ensures long life and durability
• Standard epoxy internal and external coating extend vessel life
• Schedule 80 PVC piping enhances corrosion-resistanceSYSTEM SPECIFICATIONS
Model Number . . . . . . . . . . . . . . . . . . . . . . . VPEC/VPAC-024 VPEC/VPAC-630 VPEC/VPAC-636 VPEC/VPAC-742Flow Rates
Good . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 48 72 96Better . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 24 36 48Best . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 12 18 24
Backwash Flow Rate . . . . . . . . . . . . . . . . . . 31 49 71 96Rinse Flow Rate . . . . . . . . . . . . . . . . . . . . . . 19 29 42 58Media (cubic feet) . . . . . . . . . . . . . . . . . . . . . 8 12 18 24System Dimensions*Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/2” 1-1/2” 2” 2”Column Size (D x H)
inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 x 48 30 x 60 36 x 60 42 x 72cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61x122 77x153 92x153 107x183
H x W x D Simplex (Duplex) – inch . . . . . . . 76x43x41 (80x97x41) 90x43x48 (94x97x48) 96x45x54 (100x97x54) 112x47x58 (116x133x58)cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193x110x104(204x247x104) 229x110x122 (239x246x122) 244x114x137 (254x246x137) 285x119x147 (295x338x147)
Shipping Weightlb. – Simplex (Duplex) . . . . . . . . . . . . . . . . 1,000 (2,000) 1,380 (2,760) 2,190 (4,380) 3,160 (6,320)kg – Simplex (Duplex) . . . . . . . . . . . . . . . . 454 (908) 626 (1,252) 994 (1,987) 1,433 (2,866)
Operating Weightlb. – Simplex (Duplex) . . . . . . . . . . . . . . . . 1,800 (3,600) 2,580 (5,160) 4,340 (8,680) 6,090 (12,180)kg – Simplex (Duplex) . . . . . . . . . . . . . . . . 817 (1,633) 1,171 (2,341) 1,969 (3,938) 2,762 (5,524)
Electrical Requirements . . . . . . . . . . . . . . . 110 V / 60 Hz / 1 ph / 3 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Number . . . . . . . . . . . . . . . . . . . . . . . VPEC/VPAC-648 VPEC/VPAC-754 VPEC/VPAC-760 VPEC/VPAC-772Flow Rates
Good . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 160 200 300**Better . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 80 100 150Best . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 40 50 75
Backwash Flow Rate . . . . . . . . . . . . . . . . . . 126 159 196 283Rinse Flow Rate . . . . . . . . . . . . . . . . . . . . . . 75 95 118 170Media (cubic feet) . . . . . . . . . . . . . . . . . . . . . 32 40 50 75System Dimensions*Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1/2” 3” 3” 3”Column Size (D x H)
inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 x 60 54 x 72 60 x 72 72 x 72cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122x153 139x183 153x183 183x183
H x W x D Simplex (Duplex) – inch . . . . . . 106x54x65 (110x132x66) 121x61x75 (127x158x75) 125x64x81 (131x158x81) 129x72x93 (136x158x93)cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269x137x165 (279x335x168) 307x155x191 (323x401x191) 318x163x206 (333x401x206) 328x183x236 (345x401x236)
Shipping Weightlb. – Simplex (Duplex) . . . . . . . . . . . . . . . . 4,040 (8,080) 5,550 (11,100) 7,065 (14,130) 10,210 (20,420)kg – Simplex (Duplex) . . . . . . . . . . . . . . . . 1,833 (3,666) 2,517 (5,034) 3,205 (6,410) 4,631 (9,262)
Operating Weightlb. – Simplex (Duplex) . . . . . . . . . . . . . . . . 7,940 (15,880) 10,570 (21,140) 13,275 (26,550) 19,200 (38,400)kg – Simplex (Duplex) . . . . . . . . . . . . . . . . 3,602 (7,204) 4,794 (9,588) 6,021 (12,042) 8,709 (17,418)
Electrical Requirements . . . . . . . . . . . . . . . 110 V / 60 Hz / 1 ph / 3 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ORDERING INFORMATIONVP Series Carbon Filters have extensive option packages. For ordering instructions, or additional product information, please contact technical support at 800.875.7873 extension 5000.* Approximate** Rating for metallic piping only. Plastic piping requires aeration due to line velocities.In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Section Table of ContentsBACK
A complete line of standard carbon tower units designed for the beverage industry or any
application that can utilize hot water or steam sanitization for dependable operation. The CT
Series designation refers to beverage grade carbon towers with stainless steel pressure vessels,
face piping and internal distributors. The units are available with programmable logic controllers
(PLC) or manual operation. Carbon media and other optional equipment can be easily selected
and ordered to address your specific requirements.
• For pretreatment applications requiring removal of chlorine, chloramine, and many types oforganic contaminants
• Vessels are designed for hot water sanitization and steam vapor stripping/sanitization, bottomand/or top entry, for removing VOC’s such as trihalomethanes
• Standard system is based on 1 gpm/ft3 and a backwash rate near 2 gpm/ft3 (dependent uponcarbon density and particle size)
• Uses advanced well screen internals to guarantee uniform distribution during draw-off and backwashing
• Units available with PLC or manual operation
• Vessels, piping and internals available in 316L or 304 stainless steel combinations
• Full Drainability using scavenger screen ensures continuous complete removal of condensate during steaming
• Higher flow systems, manway types, temperature and control probes, special carbon attributes, sampling ports, and finishes canbe customized with minimal impact on delivery and cost
22 ACTIVATED CARBON FILTERS
CT Series Carbon TowersFlow Rates from 57 to 382 gpm
Siemens Water Technologies24-hr Customer Service: 800.466.7873
SYSTEM SPECIFICATIONSModel Number CT050 CT100 CT150 CT200 CT250 CT300 CT350
Service Flow Rate . . . . . . . . . . . . . . . . . . 57 gpm 118 gpm 170 gpm 231 gpm 265 gpm 302 gpm 382 gpmBackwash Flow Rate*. . . . . . . . . . . . . . . . <96 gpm <196 gpm <283 gpm <385 gpm <442 gpm <503 <636 gpmMedia Volume of Carbon (cu. ft.) . . . . . . . 57 118 170 231 265 302 382Shell Diameter . . . . . . . . . . . . . . . . . . . . . 42" 60" 72" 84" 90" 96" 108"Carbon Bed Depth . . . . . . . . . . . . . . . . . . >5’ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freeboard Above Carbon . . . . . . . . . . . . . >50% . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Design Pressure . . . . . . . . . . . . . . . . . . . . 65 or 100 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . Automated (PLC) or Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Underdrain System. . . . . . . . . . . . . . . . . . Well Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manway . . . . . . . . . . . . . . . . . . . . . . . . . . Top. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . 120 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *At 10 gpm/ft2 and depends on carbon density and particle size.
ORDERING INFORMATION
Catalog Number: CT 050 A 6 6 A
System Name . . . . . . . . . . . . . CT 050, 100, 150,Model Number . . . . . . . . . . . 200, 250, 300, 350
A = 100 psiDesign Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B = 65 psi 6 = 316L VesselVessel Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 = 304 Vessel 6 = 316L PipingPiping Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 = 304 Piping A = Automatic OperationValves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M = Manual Operation
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Section Table of ContentsBACK
Valve Kits: For integration of the HOT Series System with existing 5 valve carbon towers, 2 additional valves are necessary for proper interconnection. The part numbers below are for a kit of 2valves. Order 1 kit for each existing carbon tower that the HOT System will be used with.
It is critical to consider the HOT Series System must work in conjunction with either a new or an existing carbon tower that is rated for a minimum of 65 PSI andequipped with ASME pressure relief valves.
The HOT Series is intended for applications with both new or existing carbon towers. The backwash flow rates and pump sizing of the HOT Series system arebased on the CT Series carbon towers. Some older, existing carbon towers utilize a 2’ bed depth or a wider, stockier vessel. This would change the requiredflow rates of the backwash and sanitization steps of the HOT process. HOT Series systems can be incorporated witheither style of carbon tower. A Siemens Applications Engineer will ensure the HOT Series system is sized correctly for retrofit vessels.In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
23ACTIVATED CARBON FILTERS
Heat Optimized Technology“HOT” Series Systems for Carbon TowersFor use with new or existing carbon towers
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
ORDERING INFORMATIONCatalog No.: 67/HOT 250 T A CHeat Optimized Technology System . . . . . . 67/HOTFlow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 - Backwash: 96–283 GPM
(For Siemens CT050, CT100, and CT150)250 - Backwash: 284– 442 GPM
(For Siemens CT200 and CT250) T - SS Tubing with Threads, 350 - Backwash: 443–636 GPM Flanges and Tri-clamps
(For Siemens CT300 and CT350) S - SS Tubing with Tri-clampsPiping Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . only, 180 grit ID polish 2 - 208/240 VAC, 3 Phase, 60 HzElectrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 480 VAC, 3 phase, 60 Hz Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A - Automatic C - Cooling
Exchanger Included
N - No Cooling Cooling Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exchanger
Bacteria in production water and biofouling of water treatment systems can create operationalchallenges for Beverage and BioPharm manufacturers. To meet these challenges, the “HOT”Series systems were introduced. HOT technology is a Siemens patented process that providesthorough sanitization of new or existing carbon towers, reduces backwash water by up to 75%,and adds process control. HOT Series systems use hot water to eliminate the potential for bedcontamination that can exist from utilizing plant steam. A HOT Series system can be providedindependently, with or without an optional chilling exchanger, or as a complete systemincluding carbon towers and ancillary equipment.
• Field proven to provide more effective microbial kill than conventional steaming processes• More thorough kill lessens the bacteria counts, to significantly increase periods between sanitizations• Available with fully automated or manual operation• All stainless steel skid and process piping• Fully wired and hydrostatically tested prior to shipment• Less biofouling and cleaner carbon significantly increase carbon performance and substantially reduce costs• The heating system is capable of sanitizing the loop distribution piping and polishing equipment for improved operations• Bacteria control is improved due to uniform heating of the carbon bed in the expanded state with reduced potential for cold
spots during sanitization.
Comparison Of Heat Sanitization Techniques Within A Single 84” Diameter Carbon TowerTime Conventional Steaming HOT Series Systems HOT Series with
Optional Chilling Exchanger
Backwash to Drain (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5 5Backwash Recycle & Heat (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . — 60 60Heat-Up (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 — —Hold Time (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 – 60 — 15 – 30Cool Down (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480 480 60Rinse to Drain (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5Total Time (Minutes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805 550 160
(Hours) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.4 9.2 2.2Operator Attention (Hours) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 0.5 0.5Total Water Used (Gallons) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13,800 4,500 4,500
Beverage manufacturers who have extremely low bacteria specifications are utilizing loop configuration water distribution systems to keep the water moving more effectively than “deadended” systems. The heating system included with the HOT Series Systems can serve double duty by sanitizing the loop distribution piping and polishing equipment as well.
24
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
ACTIVATED CARBON MEDIA
Activated Carbon Media
Siemens Water Technologies is a national provider of complete turnkey carbon services.
We inventory a full line of premium Westates® activated carbons made from high
quality bituminous coal, coconut shell and anthracite coal raw materials. Applications
for activated carbon include improving the taste and quality of drinking water, treating
industrial wastewater, purifying materials used in production processes, controlling air
emissions, and filtering contaminants out of groundwater in environmental cleanup
sites. Our laboratory analyzes and certifies the quality of all the activated carbon
supplied through an extensive QA/QC program. Our strategically located service centers
allow for efficient and prompt delivery and service.
Applications• Chlorine removal
• Chloramine removal
• VOC control from air strippers, soil vapor extraction and air sparge systems
• Remediation
• Solvent Recovery
• Odor Control
• Trace Organics
• Disinfection By-products
Westates® Activated Carbon Products• Vapor Phase Carbons
• Liquid Phase Carbons
• Bulk Carbons
• Coconut-Shell Carbons
• Bituminous Coal Carbons
• Impregnated Carbons
• Anthracite Carbons
• Midas® Odor Control Media
• VoCarb® Carbon
• AquaCarb® Carbon
Midas® Odor Control Media (OCM)Midas® OCM is a breakthrough in odor control. Unlike any other odor control media,
Midas OCM is manufactured in a special process combining selected active ingredients
and premium quality bituminous coal to produce an extraordinarily high H2S
breakthrough capacity. This odor control media is not impregnated and therefore does
not suffer the serious drawbacks associated with alkali-impregnated carbons. The lack of
impregnant means all of Midas OCM’s pore volume and surface area are available for
storing the sulfur produced during the catalytic oxidation of H2S and for the adsorption of
any VOCs that may be present in the gas stream. And, since Midas OCM is not
impregnated, it is safer to load, start-up and remove from an adsorber system.
For a complete list of our Activated Carbon Turnkey Services, see page 216.
25
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ANALYTICAL TEST KITS, ANALYZERS, SAMPLING DEVICES
Analyzers, Test Kits, Sampling Devices
FOULING INDEX TEST KIT (SILT DENSITY INDEX)Used to measure the amount of colloidal particulate matter in a water stream,includes a filter disc holder, pressure regulator, pressure gauge, tweezers, filter discs,valves and fittings. Also required, but not included, is a timing device (stop watch, orwrist watch with a second hand). Measurement is made by passing the stream ofwater at a constant pressure through the filtration disc for a predetermined amountof time.
SILICA ANALYZERFully automated, continuous silica monitor measures silica in a single stream ofwater in the 0-100 ppb range. The monitor uses a silica molybate colorimetricprocedure to measure resistive silica. Sulfuric acid and ammonium molybdate areadded to the water sample, forming molybdosilica acid. Oxalic acid is used toreduce the molybdosilica acid to a molybdenum blue complex, which ismeasured photometrically at 810 nm. The silica analyzer requires 115V AC foroperation, and comes with a one month supply of all necessary reagents,calibration solutions, and replacement tubing harness.
CHLORINE ANALYZERDesigned to provide an alarm signal when the total available chlorine in a watersample exceeds a preset limit. Has a 0.5 mg/L range, 0.01 mg/L resolution, andautomatic color/turbidity compensation. Uses the DPD colorimetric method tomeasure free chlorine.
HARDNESS MONITORDesigned to provided an alarm signal when the total hardness in the watersample exceeds a preset limit. The alarm trip point for this detector is 2 mg/L. Theunit performs an analysis every two minutes. The hardness monitor uses abuffered colorimetric indicator to detect total hardness. A color is developedfollowing the addition of an indicator reagent and a buffer in precise proportions.Color development is monitored by a colorimetric photometer. Three consecutive“hard” indications are required before an alarm circuit is activated; two before thealarm is cancelled. All reagents are included in the initial kit.
DISSOLVED SOLIDS METERHand-held analog meter measures three ranges of dissolved solids (0-50, 0-500and 0-5000 ppm) and features automatic temperature compensation, and abuilt-in cell cup that contains self-maintaining electrodes that never needreplatinizing.
DUAL SCALE UNIVERSAL HYDROMETERMeasures the density of liquids both lighter and heavier than water. This plainform hydrometer is 15" (38cm) long, with a specific gravity range of 0.700 to2.00 (Baume 10 to 70° light, 0 to 70° heavy).
MICROBIOLOGICAL ANALYSIS MONITORS, 37mmTwo-piece disposable monitor for microbiological analysis of samples by eithervacuum filtration or for use with an ESP sampling valve. The 0.45 mm pore sizefilter is grid marked to aid in counting colonies grown on the surface.
ANATEL® A1000 S20P PORTABLE TOC METERRugged unit combines a sensor with controller, printer and carrying handle forconvenient portability within your water system. This unit provides TOC analysisto 0.05 ppb without the inconvenience of acids, oxidants, and gases.
ORDERING INFORMATION
Catalog No. Description
ZWRQ03275 Fouling Index Test Kit
METSI6000001 Silica Analyzer
METCL4678002 Chlorine Analyzer
HDREGTKIT Hardness Monitor ReplacementReagent Kit
METCDML532T1 Dissolved Solids Meter
METHY0828720 Dual Scale Universal Hydrometer
MHWG 037 00 Microbiological Analysis Monitor,white grid 50/pk
ZTOCA1S20P Anatel® A1000 S20P Portable TOC Meter
METHD4270002 Hach® Hardness Monitor
26 ANALYTICAL TEST KITS, ANALYZERS, SAMPLING DEVICES
Analyzers, Test Kits, Sampling Devices
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
ALKALINITYUse a drop count titration method for the measurement of carbonates, bicarbonates,hydroxides, and other dissolved salts. In this kit an indicator is added to the sample, andthen a dropper is used to add the titrant until the color changes. Kit includes enoughreagents to perform approximately 100 phenolphthalein and 100 total (as CaCO3) tests.
CARBON DIOXIDEUse a drop count titration method for the measurement of carbon dioxide. An indicatoris added to the sample, and then a dropper is used to add the titrant until the colorchanges. Kit includes enough reagents to perform approximately 200 tests.
CHLORINE - LOW RANGEUse a color disk that features a continuous-gradient color wheel for fast, accuratecomparisons for chlorine measurement. The color wheel is simply rotated to obtain acolor match with the treated sample. Each kit includes enough reagents to performapproximately 100 tests.
CHLORINE - MID AND HIGH RANGEUse a drop count titration method to measure chlorine. An indicator is added to thesample, and then a dropper is used to add the titrant until the color changes. Kitmeasures total chlorine in the range of 10-200 mg/L. Kit includes enough reagentsto perform approximately 100 tests.
HARDNESSUse a drop count titration method for the measurement of calcium and magnesium. Anindicator is added to the sample, and then a dropper is used to add the titrant until thecolor changes. Kit measures total hardness at CaCO3 in the range of 1-20 mg/L. Kitincludes enough reagents to perform approximately 100 tests.
IRONUse a color disk that features a continuous-gradient color wheel for fast, accuratecomparisons for iron measurement. The color wheel is simply rotated to obtain a colormatch with the treated sample. Kit measures Fe in the range of 0-5 mg/L. Each kitincludes enough reagents to perform approximately 100 tests.
pHMost natural waters range from pH 4 to pH 9. Uses a color disk that features acontinuous-gradient color wheel for fast, accurate comparisons. The color wheel issimply rotated to obtain a color match with the treated sample. Kit measures pH in therange of 4-10. Each kit includes enough reagents to perform approximately 300 tests.
SILICA-LOW RANGEUses a color disk that features a continuous-gradient color wheel for fast, accuratecomparisons. The color wheel is simply rotated to obtain a color match with the treatedsample. Kit measures SiO2 in the range of 0-1 mg/L. Each kit includes enough reagentsto perform approximately 100 tests.
SILICA-HIGH RANGEUses a color disk that features a continuous-gradient color wheel for fast, accuratecomparisons. The color wheel is simply rotated to obtain a color match with the treatedsample. Kit measures SiO2 in the range of 0-40 mg/L. Each kit includes enoughreagents to perform approximately 100 tests.
RO WATER QUALITY TEST KITConvenient, self-contained test kit provides all the materials and instructionsrequired for on-site monitoring of reverse osmosis (RO) systems, for both feed andproduct water. Because tap water is checked, pretreatment components foroptimum RO performance can be determined. Each kit contains all materials andinstructions to perform the following tests: Silt Density Index, Total Hardness,Alkalinity, pH, Temperature, Langelier Saturation Index, Free and Total Chlorine,Soluble and Insoluble Iron, Carbon Dioxide and Silica.
ORDERING INFORMATION
Catalog No. Description
KIT2444301 Alkalinity Test Kit
REAG2437401 Replacement reagent set (approx. 100 tests)
KIT143601 Carbon Dioxide Test Kit
REAG2437500 Replacement reagent set (approx. 200 tests)
KIT1454201 Chlorine-Low Range, as free Cl2 down to 0.2 mg/L
KIT1454202 Chlorine-Low Range, as total Cl2 down to 0.2 mg/L
KIT1454200 Chlorine-Low Range, as free and total Cl2 down to 0.02 ppm mg/L
REAG1406499 Replacement reagent set total chlorine
REAG1407099 Replacement reagent set free chlorine
REAG2440400 Replacement reagent set free & total chlorine
KIT2444400 Chlorine-Mid and High Range Test Kit
REAG2437700 Replacement reagent set (approx. 100 tests)
KIT145201 Hardness Test Kit
REAG2437800 Replacement reagent set (approx. 100 tests)
KIT146400 Iron Test Kit
REAG92799 Replacement reagent set (approx. 100 tests)
KIT147011 pH Test Kit
REAG2329332 Replacement reagent set (approx. 300 tests)
KIT2255000 Silica-Low Range Test Kit
REAG2462200 Replacement reagent set (approx. 100 tests)
KIT1455400 Silica-High Range Test Kit
REAG2462300 Replacement reagent set (approx. 100 tests)
HAWP04700 Replacement filters for Fouling IndexTest Kit
TESTKITUP RO Water Quality Test Kit
27
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ANALYTICAL TEST KITS, ANALYZERS, SAMPLING DEVICES
Bacteria Samplers
Provides simple, fast microbiological analysis of surface, natural source, make-up,
process and laboratory-grade water (or high-purity). Extremely versatile for
sampling fluids and different types of surfaces and crevices. Can be used in a
variety of industries including beverage bottling/canning, cosmetic and
pharmaceutical manufacturing, food processing. Each sampler absorbs 1 mL of
sample. Consists of a plastic tab supporting a 0.45 µm filter bonded to an
adsorbent pad containing dehydrated nutrient medium, and all contained in a
transparent plastic case.
• Filter surface is grid-marked to permit counting colonies
• Presterilized and ready for use, the sample does not require special preparation
• Entire assembly is sterilized and packaged in a sealed plastic envelope. Samples
may be used in conjunction with the swabbing unit for surface-sanitization.
This is a cotton-tipped swab stick in sterile buffer contained in a vial similar to
the sampler vial.
ORDERING INFORMATION
Catalog No. Description
MC0010025. . . . . Coli-count Sampler (blue) 25/pk
MY0010025. . . . . Yeast and Mold Sampler (white) 25/pk
MT0010025. . . . . Total Count Sampler (white) 25/pk
MHPC10025 . . . . HPC Total Count Sampler for Dialysis (red) 25/pk
B01040WA . . . . . Whirl-Pak® Thio-Bag® 100mL (100/pk)
28 ANALYTICAL TEST KITS, ANALYZERS, SAMPLING DEVICES
ESP Sanitary Sampling Valves
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SYSTEM SPECIFICATIONSCatalog Number ZWSSP0400 ZWSSP0800 ZWSSPW400 ZWSSPW800 ZWSSPW840 ZWSSPW441 ZWSSPW442 ZWSSPW442 9594
Type 1/4" NPTM 1/8" NPTM 1/4" weldable 1/8" weldable 1" pre-welded 1 1/ 2" pre-welded TC 2" pre-welded TC 3" pre-welded TC end cap pre-welded
Spare Parts Catalog No.Whirl-Pak® Bags (100 mL; 100/pk) B01040WAPlastic Syringes, 20 mL (12/pk). XX11 020 12Plastic Syringes, 50 mL (5/pk). . XX11 050 05Spare Parts Kit (3 Viton® o-rings,
5 syringe needles, 10 plastic caps, 3 plug seals) YY20 04K 00
Plastic Cap Only . . . . . . . . . . . . P91018Spare Parts Kit
(2 o-rings, 2 plug seals) . . P91968
The ESP sanitary sampling valve is designed for the sterile sampling of high-purity
water. It allows for mid-stream sample collection in water lines, resulting in truly
representative sampling. The unique design eliminates bacterial and particle
build-up that could interfere with bacteriological test results.
• Comes complete with two 18-gauge blunt-end syringe needles (for sanitization),
a spare set of seals, and two sealing caps (covers the Luer-slip outlet to maintain
sanitary conditions)
• Available in 1/4" (for use with 1-1/2" or larger diameter lines) and 1/8" (for use
with 3/4" or larger lines) NPT or weldable configurations
• Valves pre-welded into 1" – 3" diameter spool pieces or a 1-1/2" TC end cap is
also available
• Easily installed in liquid distribution lines; can be kept in a sanitary condition
between uses
• Bacteriological analysis monitor can be directly attached to the valves Luer-slip
outlet, or flow can be directed into any type of container
• Sampling valve body and stems constructed of 316 stainless steel
• Operational up to 100 psig (7 bar) at 25°C
29
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
BAG FILTERS
Bag Filters
BAG FILTERS (LOW FLOW)
• Polypropylene thermally welded bag
ORDERING INFORMATIONLOW FLOW 10”
Size Micron Catalog Number
10 1 D100444510 5 D100444710 10 D100444910 25 D100445110 50 D100445310 100 D100445510 200 D1004457
BAG FILTERS
• Available in #1 (7x16.5") and #2 (7x32") sizes
• Stainless steel locking ring
• Choice of polypropylene or polyester felt materials
ORDERING INFORMATIONPolypropylene
Size Micron Catalog Number
P2 . . . . . 5 FBSP05P2PP2. . . . . 10 FBSP010P2PP2. . . . . 25 FBSP025P2PP2. . . . . 50 FBSP050P2PP2. . . . . 100 FBSP0100P2P
P1. . . . . 5 FBSP05P1PP1. . . . . 10 FBSP010P1PP1. . . . . 25 FBSP025P1PP1. . . . . 50 FBSP050P1PP1. . . . . 100 FBSP0100P1P
Polyester Felt
Size Micron Catalog Number
P2 . . . . . 1 FBWPE1P2SP2. . . . . 5 FBWPE5P2SP2. . . . . 10 FBWPE10P2SP2. . . . . 25 FBWPE25P2SP2. . . . . 50 FBWPE50P2SP2. . . . . 100 FBWPE100P2S
P1. . . . . 1 FBWPE1P1SP1. . . . . 5 FBWPE5P1SP1. . . . . 10 FBWPE10P1SP1. . . . . 25 FBWPE25P1SP1. . . . . 50 FBWPE50P1SP1. . . . . 100 FBWPE100P1S
BAG FILTERS (SEWN-CASE QUANTITIES ONLY)
• Polypropylene or polyester
ORDERING INFORMATIONPolypropylene Felt
Size Micron Catalog Number
P2 . . . . . 1 FBWPO1P2SP2. . . . . 5 FBWPO5P2SP2. . . . . 10 FBWPO10P2SP2. . . . . 25 FBWPO25P2SP2. . . . . 50 FBWPO50P2SP2. . . . . 100 FBWPO100P2S
P1. . . . . 1 FBWPO1P1SP1. . . . . 5 FBWPO5P1SP1. . . . . 10 FBWPO10P1SP1. . . . . 25 FBWPO25P1SP1. . . . . 50 FBWPO50P1SP1. . . . . 100 FBWPO100P1S
ORDERING INFORMATIONPolyester
Size Micron Catalog Number
P2 . . . . . 5 FBSPE5P2SP2. . . . . 10 FBSPE10P2SP2. . . . . 25 FBSPE25P2SP2. . . . . 50 FBSPE50P2SP2. . . . . 100 FBSPE100P2S
P1. . . . . 5 FBSPE5P1SP1. . . . . 10 FBSPE10P1SP1. . . . . 25 FBSPE25P1SP1. . . . . 50 FBSPE50P1SP1. . . . . 100 FBSPE100P1S
ORDERING INFORMATIONLOW FLOW 20”
Size Micron Catalog Number
20 1 D100444620 5 D100444820 10 D100445020 25 D100445220 50 D100445420 100 D100445620 200 D1004458
30
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
STAINLESS STEEL NON-CODE BAG FILTER HOUSINGS*
• 316SS construction
• BUNA-N O-ring
• 2" NPTF threaded or 2” RF 150lb ANSI flanged
• Available in 65 gpm (size P1) or 125 gpm (size P2) flow rates
• Rated at 150 psi @ 200°F
ORDERING INFORMATIONCatalog Number:
P1 . . . . . . . . . FBHFBF111S
P2 . . . . . . . . . FBHFBF112S
P1 (Flng). . . . FBHFBF111SFP2 (Flng). . . . FBHFBF112SF
STAINLESS STEEL ASME CODE BAG FILTER HOUSINGS*
• 316SS construction
• BUNA-A O-ring
• RF 150lb ANSI flanged connections
• Single bag housings available with swing bolt closure
• Multi bag housings have swing bolt spring-assist closure, see flow rates below
• Rated at 150 PSI @ 200˚F
ORDERING INFORMATIONSize Flow Rate Connection Part Number
1 bag . . . . . . . . . . P1 65 2” FBHTBF111S
1 bag . . . . . . . . . . P2 125 2” FBHTBF112S
3 bag . . . . . . . . . . P2 230 3” FBHF3AV0300001
4 bag . . . . . . . . . . P2 400 4” FBHF3AV0400001
6 bag . . . . . . . . . . P2 675 6” FBHF3AV0600001
8 bag . . . . . . . . . . P2 900 8” FBHF3AV0800001
BAG FILTERS
Bag Filter Housings
31BAG FILTERS
Bag Filter Housings
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
PLASTIC BAG FILTER HOUSINGS (STANDARD FLOW)
• Heavy duty reinforced polypropylene construction• Viton® Seals• 2" NPTF connections• Available in 50 gpm (size P1) or 100 gpm (size P2) flow rates• Rated at 150 psi @ 80°F• Duplex valved A/B bank divert operation
ORDERING INFORMATIONInlet/Outlet Flow Rate Part#
10" . . . . . . . . . . . 1" 15 GPM D1004442
10" . . . . . . . . . . . 1.5" 20 GPM D1004443
20" . . . . . . . . . . . 1" 15 GPM FC150367
20" . . . . . . . . . . . 1.5" 20 GPM D1004444
PLASTIC BAG FILTER HOUSINGS
• Polypropylene construction
• Choice of 10” or 20” housings
• Comes with gauge, wrench and 3/8” drain valve
• Available in 1” and 1 1/2” NPT sizes
• Large Acme thread closure
ORDERING INFORMATIONCatalog Number:
P1 . . . . . . . . . FBHFLT4201
P2 . . . . . . . . . FBHFLT4202
P1 (duplex) . . FBHFLT1DUP
P2 (duplex) . . FBHFLT2DUP
7
K
CARTRIDGE DESIGN DESCRIPTION CODE
Gaskets compressed on knife edge seal Fof housing
O-rings are locatedexternally on the 0cartridge
O-rings are locatedexternally on the 5cartridge
Single O-ring located inside 10the cartridge
The following table is presented as reference when ordering filter cartridges. For
more detailed information, please contact our Technical Support Team at 800-875-
7873 ext. 5000.
Code F Style CartridgesDouble open end with flat gasket
Code 10 Style CartridgesSingle Open End with 1-120 Internal O-Ring at Open End
Code O Style CartridgesSingle Open End with
2-222 O-Ring with Seal
Code 5 Style CartridgesSingle Open End
2-222 O-Ring Seal andSpear End Assembly
Code 7 Style CartridgesSingle Open End with
2-226 O-Ring Locking Seal andSpear End Assembly
O-rings are located externally on the cartridge. The adapterlocks into the housingwith spear assembly
Code K SOE plastic spring assembly, saw cut end
Knife edge SOEwith spring seal
32
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTERS
Cartridge End Caps
33
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - ACTIVATED CARBON
Granular Activated Carbon Filter Cartridge
• Composed of lignite-based granular activated carbon in an upflow cartridge
design for removing chlorine feed water
• Cartridge is designed to allow water to enter the bottom of the cartridge, then
filtered through the entire carbon bed before exiting at the top to maximize
the contact time and therefore the adsorption
• Internal expansion pad maintains a tight, compact column to minimize
channeling or bypass
• Nominal 20 micron post-filter reduces carbon fines as well as other suspended
particles
SPECIFICATIONSDimensions 10" Cartridge 20" Cartridge
Diameter (OD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.875" (7.3 cm) 2.875" (7.3 cm)Length (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.75" (24.8 cm) 20" (50.8 cm)
Recommended Water Flow Rates
10" Cartridge Maximum . . . . . . . . . . . . . . . . . . . . . 1.0 gpm (3.8 lpm) 2.0 gpm (7.6 lpm)
Materials
Filter Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Granular, Activated CarbonPost filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spun PolypropyleneExpansion Pad Foam . . . . . . . . . . . . . . . . . . . . . . . Polyether/PolyurethaneOuter Casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PolystyreneEnd Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PolystyreneGaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Buna-N
Operating Parameters
Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . 32 to 125°F (0 – 52°C)
Carbon Volume . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ounces of granular carbon per 10" length
ORDERING INFORMATIONCatalog Number Description
FCGC . . . . . . . . . . . . . Filter cartridge granular carbon
F . . . . . . . . . . . . . . . . . Cartridge Code: F = flat gasket seal
XX . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20
20 . . . . . . . . . . . . . . . . Nominal micron retention rating
To determine your catalog order number, replace the X with one of the numbered or lettered options beside it.
• Composed of pre-washed, finely pulverized activated carbon, encapsulated in a
depth filtration media of highly purified alpha-cellulose and synthetic fibers for
removing chlorine
• Depth-type cartridge ensures superior dirt holding capacity in sediment-laden
waters to minimize premature exhaustion while it is being carbon treated
• Design includes a thermally bonded outer, nominal 10 micron pre-filtration
layer that provides for depth filtration in one pass without carbon channeling
or media migration
SPECIFICATIONSDimensions 10" Cartridge 20" Cartridge
Diameter (OD). . . . . . . . 2.75" (7.0 cm) 2.75" (7.0 cm)Length (in). . . . . . . . . . . 9.75" (24.8 cm) 20" (50.8 cm)
Recommended Water Flow Rates
Maximum . . . . . . . . . . . 1.0 gpm (3.8 lpm) 2.0 gpm (7.6 lpm)
Materials
Primary filter media . . . . . . . . . . . . . . . . Pulverized, Activated CarbonInner Layer Media . . . . . . . . . . . . . . . . . Alpha Cellulose and Synthetic FibersInner Core . . . . . . . . . . . . . . . . . . . . . . . PolypropyleneOuter Netting . . . . . . . . . . . . . . . . . . . . . PolyolefinEnd Caps. . . . . . . . . . . . . . . . . . . . . . . . Low Durometer Polyethylene
Operating Parameters
Temperature Range . . . 32 to 125°F (0 – 52°C)
Carbon Volume
. . . . . . . . . . . . . . . . . . . 3.7 ounces of pulverized carbon per 10" length
ORDERING INFORMATIONCatalog Number Description
FCPC . . . . . . . . . . . . . . Filter cartridge pulverized carbon
F . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20
10 . . . . . . . . . . . . . . . . . Nominal micron retention rating
To determine your catalog order number, replace the X with one of the numbered or lettered options beside it.
34
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - ACTIVATED CARBON
Pulverized Activated Carbon FilterCartridge
35
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
DI GARD™ String Wound Prefiltration Cartridges
• Designed for a variety of prefiltration applications such as SDI (service
deionization), reverse osmosis, and CDI® (Continuous Deionization) systems
• String wound type filter with your choice of cotton, industrial or surfactant-free
polypropylene string over a polypropylene core
• Large void volume design for low-cost, reliable filtration performance with high
contaminant holding capacity
• Continuous filter winding in 20-, 30-, and 40-inch lengths prevents by-passing
or excessive pressure drops at the seams
• Gasketed end caps on 0.5 µm rated filters for positive sealing that eliminates
by-passing
• Surfactant-free FCPX style filter meets USP Class VI Biological Tests for Plastics
requirements
SPECIFICATIONSDimensions
Diameter (OD). . . . . . . . 2.5" (6.5 cm)Length (in). . . . . . . . . . . 9.75, 10, 19.5, 20, 29.25, 30, 40
Materials
FCCS . . . . . . . . . . . . . . FDA-Listed bleached white cotton fiber stringmedia with polypropylene core
FCPS . . . . . . . . . . . . . . FDA-Listed polypropylene fiber string media with polypropylene core
FCPX . . . . . . . . . . . . . . Surfactant-free polypropylene fiber string media with polypropylene core
. . . . . . . . . . . . . . . . . . . NOTE: Code F cartridges (0.5 µm) have santophrene end seals.
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . 140°F (60°C)Maximum Differential Pressure @ 25°C 50 psi (3.4 bar)Micron Ratings. . . . . . . . . . . . . . . . . . . . 0.5, 1, 3, 5, 10, 20, 50 MicronsFiltration Efficiency . . . . . . . . . . . . . . . . Nominal 90%Recommended Water Flow Rates . . 5.0 gpm/10" length (18.9 lpm/10" length)
ORDERING INFORMATIONCatalog Number Description
FCXX . . . . . . . . . . . . . . FCCS = FDA-Listed bleached cotton string fiberFCPS = FDA-Listed polypropylene string fiberFCPX = surfactant-free polypropylene string fiber cartridge
F . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end
XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 19 = 19.5, 20 = 20, 29 = 29.25, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 20 = 20 µm, 50 = 50 µm
To determine your catalog order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult Technical Support forassistance.
• Designed for a variety of prefiltration applications such as SDI (service deionization),
reverse osmosis and CDI® (Continuous Deionization) systems
• Graded density melt spun polypropylene media design for exceptional throughput,
with high contaminant holding capacity
• Gasketed end caps on 1, 3 and 5 µm rated filters for positive sealing that eliminates
bypass contamination
• Manufactured from materials which are listed for food contact applications in Title
21 of the U.S. Code of Federal Regulations. Product in compliance with EU Directive
2002/72/EC for plastic in food contact (in simulants A, B, C, and D).
• All polypropylene components meet the specifications for biological safety as per the
USP for Class VI-121˚C plastics (gaskets/O-rings excluded).
• FCRO Series filter cartridges are free of surfactants, anti-static agents, binders, and
adhesives
• NSF Certified
SPECIFICATIONSDimensions
Diameter (OD). . . . . . . . 2.5" (6.5 cm)Length (in). . . . . . . . . . . 9.75, 10, 12, 19.5, 20, 30, 31, 40
Materials
Media . . . . . . . . . . . . . . Melt blown polypropyleneCore . . . . . . . . . . . . . . . Integral polypropylene coreO-Rings. . . . . . . . . . . . . Silicone o-ringsGaskets. . . . . . . . . . . . . Santoprene end seals
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . 140°F @ 25 psid Maximum Differential Pressure @ 25°C 50 psi (3.4 bar)Micron Ratings. . . . . . . . . . . . . . . . . . . . 1, 3, 5, 10, 20, 25, 50, 75 micronsFiltration Efficiency . . . . . . . . . . . . . . . . Nominal 90%Recommended Water Flow Rate . . . 5.0 gpm/10" length (18.9 lpm/10" length)
ORDERING INFORMATIONCatalog Number and Description
FCRO . . . . . . . . . . . . . . Rogard II all polypropylene depth cartridge
X . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end (1&5 µm w/gasket) K = knife edge seal with spring seal0 = 2-222 o-rings (12&20", 1&5 µm only)N = double open end (1, 3 & 5 µm – no gasket)
XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 12 = 12, 19 = 19.5, 20 = 20, 30 = 30, 31 = 31, 40 = 40
XX . . . . . . . . . . . . . . . . . Micron Rating: 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm,20 = 20 µm, 25 = 25 µm, 50 = 50 µm, 75 = 75 µm
To determine your catalog order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult Technical Support forassistance.
36
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
ROGARD™ Graded Density PolypropyleneMedia Filter Cartridge
37
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
Prepure DP™ Graded DensityPolypropylene Depth Media Filter Cartridge
• Composed of graded density melt blown polypropylene depth media for high
efficiency prefiltration and post-filtration of DI resin applications
• Prepure DP™ filtration cartridges feature high contaminant loading due to graded
density depth filtration media construction
• FDA Listed Materials - Manufactured from materials which are listed for food
contact applications in Title 21 of the U.S. Code of Federal Regulations
• All components meet the specifications for biological safety as per the USP for Class
VI-121˚C plastics (gaskets/O-rings excluded).
• Virgin polypropylene construction with fusion welding minimizes extractables
SPECIFICATIONSDimensions
Diameter (OD). . . . . . . . 2.6" (6.6 cm)Length (in). . . . . . . . . . . 9.75, 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . Non-woven melt blown polypropyleneSeals . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . 180°F (82°C) @ 15 psidMaximum Differential Pressure @ 20°C 75 psid (5.2 bard)Filtration Efficiency . . . . . . . . . . . . . . . . Nominal 90%
Recommended Water Flow Rates
0.5 – 5 micron. . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)10 – 50 micron . . . . . . . 5.0 gpm/10" length (18.9 lpm/10" length)
Sanitizing Agents. . . . Chlorine or hydrogen peroxide
ORDERING INFORMATION
Catalog Number and Description
FCDP . . . . . . . . . . . . . . All polypropylene depth filter cartridge
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-rings w/spear1 = single open end w/internal o-ringF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 25 = 25 µm, 50 = 50 µm
To determine your catalog order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult Technical Support forassistance.
Media Grade Nominal 99.9% AbsS5 .5 11 1 33 3 55 5 10
10 10 2025 25 4050 50 70
• Designed to deliver precision prefiltration through the patented advanced melt
blown structure that incorporates large diameter fibers for strength while
maintaining small fibers for filtration
• High purity, 100% polypropylene construction is free of surfactants, binders
and adhesives
• FDA Listed Materials - Manufactured from materials listed for food contact
applications in Title 21 of the U.S. Code of Federal Regulations. Product (3
micron and higher) in compliance with EU Directive 2002/72/EC for plastic in
food contact (in simulants A, B, C, and D).
• Toxicity - All polypropylene components meet the specifications for biological
safety as per the USP for Class VI-121˚C plastics (gaskets/O-rings excluded).
38
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
NT Series Graded Pore Polypropylene Depth Filter Cartridge
SPECIFICATIONSDimensionsDiameter (OD). . . . . . . . 2.5" (6.5 cm)Length (in). . . . . . . . . . . 9.75, 10, 20, 30, 40
MaterialsCartridge . . . . . . . . . . . . Polypropylene caps and coreMedia . . . . . . . . . . . . . . CoLD® fiber melt blown polypropyleneSeals . . . . . . . . . . . . . . . Silicone o-rings and Santoprene® gaskets
Operating ParametersMaximum Temperature
0.5-10 µm: . . . . . . . . . . . . . . . . . . . 15 psid (1.03 bard) @ 180˚F (82˚C)25 psid (1.72 bard) @ 150˚F (66˚C)60 psid (4.14 bard) @ 86˚F (30˚C)
15-120 µm: . . . . . . . . . . . . . . . . . . . 25 psid (1.72 bard) @ 140˚F (60˚C)50 psid (3.45 bard) @ ambient
Maximum Differential Pressure @ 30°C 60 psi (4.1 bar)Filtration Efficiency . . . . . . . . . . . . . . . . Nominal 90%
Recommended Water Flow Rates0.5 – 3 micron. . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)5 – 75 micron . . . . . . . . 5.0 gpm/10" length (18.9 lpm/10" length)
Sanitizing Agents . . . Chlorine, hydrogen peroxide
Autoclaving:Single open end FCNT Series filter cartridges can be autoclaved for 30 minutes at 250˚F(121˚C) under no end load conditions. However, filter cartridges should be allowed to cool tonormal system operating temperatures prior to use.
Steam Sterilization:Not recommended.
ORDERING INFORMATIONCatalog Number and Description
FCNT . . . . . . . . . . . . . . Polypropylene CoLD® depth filter cartridge
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings7 = 2-226 o-ring locking tabs w/spear1 = single open end w/internal o-ringN = double open end (0.5 – 5 mm – no gasket)
XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 15 = 15 µm, 20 = 20 µm, 30 = 30 µm, 40 = 40 µm, 50 = 50 µm, 75 = 75 µm
To determine your catalog order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult Technical Support forassistance.
39
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
Postpure PP™ Graded Density PleatedPolypropylene Depth Media Filter Cartridge
• Composed of graded-density, pleated, polypropylene depth media for high efficiency
postfiltration of DI resin applications
• FDA Listed Materials - Manufactured from materials which are FDA listed for food
contact applications in Title 21 of the U.S. Code of Federal Regulations.
• Toxicity - All polypropylene components meet the specifications for biological safety as
per the USP for Class VI-121˚C plastics (gaskets/O-rings excluded).
• Cartridges are free of resins, binders and adhesives.
SPECIFICATIONS
Dimensions
Diameter (OD). . . . . . . . 2.6" (6.6 cm)Length (in). . . . . . . . . . . 10, 20, 30
Materials
Cartridge . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . Pleated, non-woven melt blown . . . . . . . . . . . . . . . . . . . polypropylene
Seals . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . 150°F (65°C) @ 40 psid (2.8 bard)Maximum Differential Pressure @ 20°C 75 psid (5.1 bard)Filtration Efficiency . . . . . . . . . . . . . . . . nominal 90%
Recommended Water Flow Rates
0.3 – 1 micron. . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)3 – 30 micron . . . . . . . . 8.0 gpm/10" length (30.1 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide, in-line with hot water (82°C) for one hour, autoclaved for 20 minutes at 121°C under no load conditions.
Sterilization
Multiple autoclaving for 30 minutes at 250˚F (121˚C) under no end load conditions. In-line steam sterilization is not recommended. May be in-line sanitized with hot water at180˚F (82˚C) for 1 hour.
ORDERING INFORMATIONCatalog Number and Description
FCPP . . . . . . . . . . . . . . All polypropylene, pleated, nominal depth filter cartridge
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 w/spear7 = 2-226 o-rings locking tabs w/spear1 = single open end w/internal o-ringF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30
XX . . . . . . . . . . . . . . . . . Micron Rating: S3 = 0.3 µm, S6 = 0.6 µm, 01 =1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 30 = 30 µm
To determine your catalog order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult Technical Support forassistance.
• Absolute filtration with sharp particle cutoffs deliver precise removal
efficiencies
• Patented melt blown structure provides outstanding retention efficiency,
mechanical strength, and long on-stream life
• High purity, 100% polypropylene construction is free of surfactants, binders and
adhesives making these cartridges ideal for use in food and beverage
applications
• FDA Listed Materials - Manufactured from materials which are listed for food
contact applications in Title 21 of the U.S. Code of Federal Regulations. Product
(5 micron and higher) in compliance with EU Directive 2002/72/EC for plastic in
food contact (in simulants A, B, C, and D).
• Toxicity - All polypropylene components meet the specifications for biological
safety as per the USP for Class VI-121˚C plastics (gaskets/O-rings excluded).
SPECIFICATIONSDimensionsDiameter (OD). . . . . . . . 2.5" (6.5 cm)Length (in). . . . . . . . . . . 9.75, 10, 20, 30, 40MaterialsCartridge . . . . . . . . . . . . Polypropylene caps and coreMedia . . . . . . . . . . . . . . CoLD® fiber melt blown polypropyleneSeals . . . . . . . . . . . . . . . Silicone o-rings and gasketsOperating ParametersMaximum Temperature . . . . . . . . . . . . .
0.5-20 µm: . . . . . . . . . . . . . . . . . . . 15 psid (1.03 bard) @ 180˚F (82˚C)25 psid (1.72 bard) @ 150˚F (66˚C)60 psid (4.14 bard) @ 86˚F (30˚C)
30-120 µm: . . . . . . . . . . . . . . . . . . . 25 psid (1.72 bard) @ 140˚F (60˚C)50 psid (3.45 bard) @ ambient
Maximum Differential Pressure @ 30°C 60 psi (4.1 bar)
Filtration Efficiency Absolute (> 99.9% Retention Rating by ASTM F-795 Test)
Recommended Water Flow Rates0.5 – 5 micron. . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)10 – 70 micron . . . . . . . 5.0 gpm/10" length (18.9 lpm/10" length)Sanitizing Agents. . . . . . . . . . . . . . . . . . . Chlorine, hydrogen peroxide
AutoclavingSingle open end Nexis® Series filter cartridges can be autoclaved for 30 minutes at 250˚F(121˚C) under no end load conditions. However, filter cartridges should be allowed to cool tonormal system operating temperatures prior to use.Steam SterilizationNot recommended
ORDERING INFORMATIONCatalog Number and Description
FCNA . . . . . . . . . . . . . . Absolute rated CoLD depth filter cartridge
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings7 = 2-226 o-rings w/spear1 = single open end w/ internal o-ringF = double open end w/flat gasket seal5 = 2-222 o-rings w/spear
XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 µm, 01 = 1 µm, 03 = 3 µm, 05 = 5 µm, 10 = 10 µm, 15 = 15 µm, 20 = 20 µm, 30 = 30 µm, 50 = 50 µm, 70 = 70 µm
To determine your catalog order number, replace the X with one of the numbered or lettered optionsbeside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
40
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
NA Series Absolute Rated PolypropyleneDepth Filter Cartridge
41
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
WN Series Pleated Polysulfone MembraneFilter Cartridge
• Composed of pleated highly asymmetric polysulfone membrane over a non-
woven polypropylene support layer
• For high flow rates and low pressure drops, absolute rated filters are designed
for postfiltration in high purity water applications
• High-purity construction materials are factory rinsed with DI water for quick on-
stream rinse up with a minimum of throughput
• Meets criteria for USP Class VI Biological tests for plastics, ensuring that no
surfactants or coatings interfere with the application
• FDA listed materials - manufactured from materials which are FDA listed for
food contact applications in Title 21 of the U.S. code of Federal Regulations
SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . . . . 9.75, 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . . Polypropylene caps, core and cage
Media . . . . . . . . . . . . . . . Single layer asymmetric hydrophilic polysulfoneSeals . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . 180°F (82°C) @ 50 psid (3.4 bard)Maximum Differential Pressure @ 20°C . 80 psi (5.5 bar)Filtration Efficiency . . . . . . . . . . . . . . . Absolute (> 99.9% Retention Rating by
. . . . . . . . . . . . . . . Latex Bead Challenge)
Recommended Water Flow Rates
0.05 micron . . . . . . . . . . . . . . . 1.3 gpm/10" length (4.9 lpm/10" length)0.1 micron . . . . . . . . . . . . . . . 1.7 gpm/10" length (6.4 lpm/10" length)0.2 micron . . . . . . . . . . . . . . . 3.0 gpm/10" length (11.3 lpm/10" length)0.45 micron . . . . . . . . . . . . . . . 5.5 gpm/10" length (20.8 lpm/10" length)
Sanitizing Agents
. . . . . . . . . . . . . . . 5% Chlorine, 3% hydrogen peroxide
ORDERING INFORMATION
Catalog Number and Description
FCWN . . . . . . . . . . . . . . Filter cartridge single layer polysulfone
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings5 = 2-222 o-rings w/spear1 = single open end w/ internal o-ring7 = 2-226 o-rings w/locking tabs/spear endF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX(X) . . . . . . . . . . . . . . Micron Rating: S05 = 0.05 µm, S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm
To determine your catalog order number, replace the X with one of the numbered or lettered options beside it.Note: Not all part number combinations are available; consult Technical Support for assistance.
• Composed of a double layer of integrity testable, highly asymmetric polysulfone
membrane. These absolute rated filters offers superior bacteria and particle
removal for high efficiency postfiltration for critical high purity water applications
• Long on stream life, high flow rates and low pressure drops result from the
membrane asymmetry
• High-purity construction materials are factory flushed with DI water for quick
on-stream rinse-up with a minimum of throughput
• All polypropylene hardware and thermal welding minimizes extractables
• All materials are FDA listed for contact with food and beverages
SPECIFICATIONS
DimensionsDiameter (OD) . . . . . . . . . . . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . . . . . . . . . . . . 9.75, 10, 20, 30, 40
MaterialsCartridge . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . . . . . . . . . . . . Double layer asymmetric hydrophilicpolysulfoneSeals . . . . . . . . . . . . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating ParametersMaximum Operating Temperature . . . . . 86°F / 30°C (158˚F / 70˚C)Maximum Forward Differential Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 psid @68˚F / 5.5 bar @ 20˚C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 psid @ 158˚F / 1.4 bar @ 70˚C
Filtration Efficiency . . . . . . . . . . . . . . . . . 99.9% Absolute
Sanitizing Agents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5% Chlorine or 3% hydrogen peroxide
Integrity TestPore Size . . . . . . . . . . . . . . . . . . . . . . . . Diffusional Flow (cc/min) @ Test Pressure
per 10” lengthDiffusional Flow Valves (100% H20) (cc/min) @ Test pressure per 10” length0.02 µm . . . . . . . . . . . . . . . . . . . . . . . . . < 30 cm3/min @ 50 psig / 3.4 bar0.1 µm . . . . . . . . . . . . . . . . . . . . . . . . . . < 24 cm3/min @ 25 psig / 1.7 bar0.2 µm . . . . . . . . . . . . . . . . . . . . . . . . . . < 20 cm3/min @ 20 psig / 1.4 bar0.45 µm . . . . . . . . . . . . . . . . . . . . . . . . . < 15 cm3/min @ 15 psig / 1.0 bar
ORDERING INFORMATIONCatalog Number:
FCWE . . . . . . Filter cartridge double layer polysulfone
X . . . . . . . . . . Cartridge Code:0 = 2-222 o-rings5 = 2-222 o-rings w/spear1 = single open end w/ internal o-rings7 = 2-226 o-rings w/locking tabs/spear endF = double open end w/flat gasket seal
XX . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX(X) . . . . . . Micron Rating: S02 = 0.02 µm, S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm
Note: Not all part number combinations are available; consult Technical Support for assistance.To determine your catalog order number, replace the X with one of the numbered/lettered optionsbeside it.
(Rinse in @ 5-6 gpm per 10" to ensure removal of air and microbubbles between the membrane layers,
especially with 0.02µ. Recommend flow per 10" is 2 gpm.)
42
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
WE Series Pleated Polysulfone MembraneFilter Cartridge
43
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
DI Series Pleated Hydrophilic PVDF MediaPharmaceutical/Biotech Grade FilterCartridge• Composed of a validatable, hydrophilic, PVDF membrane. Offering a high velocity DI
water flush for quick rinse-up with no downstream contamination.
• These absolute rated filters offer superior bacteria and particle removal for
critical high purity postfiltration applications
• Filters have single PVDF membrane with two layers of polypropylene support media to
ensure absolute bacteria retention with typical LRV >8
• The all PVDF membrane can be sanitized with chlorine, hydrogen peroxide or steam
• Virgin polypropylene construction with fusion welding minimizes extractables
• Cartridges are 100% integrity tested to verify absolute sub-micron particle retention
SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . . . . . . . . . . . . 2.75" (7.0 cm)Length (in) . . . . . . . . . . . . . . . . . . . . . . . . 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene caps, core and cage
Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hydrophilic PVDFSeals . . . . . . . . . . . . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . 176°F (80°C) @ 25 psid (1.7 bar)Maximum Differential Pressure @ 25°C . 50 psi (3.4 bar)Filtration Rating . . . . . . . . . . . . . . . . . . . . 100% Absolute
Recommended Water Flow Rates
0.1 micron . . . . . . . . . . . . . . . . . . . . . . . . 0.5 gpm/10" length (1.9 lpm/10" length)0.2 micron . . . . . . . . . . . . . . . . . . . . . . . . 1.0 gpm/10" length (3.8 lpm/10" length)
Sanitizing Agents
Chlorine, hydrogen peroxide
Sterilization
30 SIP cycles of 30 min @ 121˚C; 30 autoclave cycles of 60 min @ 121˚C
Integrity Test
Pore Size . . . . . . . . . . . . . . . . . . . . . . . . . Minimum Water Diffusional Flow (cc/min) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bubble Point @ 23˚C @ Test Pressure per 10" length in water
0.1 µm . . . . . . . . . . . . . . . . . . . . . . . . . . . > 70 psig (≥ 4.8 bar) < 20 @ 56 psig (3.8 bar)0.2 µm . . . . . . . . . . . . . . . . . . . . . . . . . . . > 45 psig (≥ 3.1 bar) < 13.3 @ 40 psig (2.8 bar)
ORDERING INFORMATIONCatalog Number and Description
FCDI . . . . . . . . . . . . . . . Filter cartridge Water DI
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings5 = 2-222 o-rings w/spear7 = 2-226 o-rings w/locking tabs/spear endF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX . . . . . . . . . . . . . . . . . Micron Rating: S1 = 0.1 µm, S2 = 0.2 µm
To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all partnumber combinations are available; consult Technical Support for assistance.
• Cartridge is a validated, pleated hydrophilic PVDF membrane over a non-woven
polypropylene support layer
• Code 0, Code 5, and Code 7 configurations are available in 10, 20 30, and 40-in lengths that are
100% tested in manufacturing to ensure absolute bacteria retention with typical titre reduction
of >107/cm2
• Quantitative retention of 107 CFU/cm2 Brevundimonas diminuta ATCC® 19146 per ASTM
methodology
• Component materials meet the criteria of the USP <88> Reactivity Test for Class VI Plastics. These
products meet the requirements of the USP <88> Safety Test, utilizing a 0.9% sodium chloride
extraction
• Component materials meet the “non-fiber releasing” criteria as defined in 21 CFR 210.3 (b) (6)
• Will meet the USP Oxidizable Substances Test requirements after a water flush of <1 L
SPECIFICATIONSDimensionsDiameter (OD). . . . . . . . 2.75" (7.0 cm)Length (in). . . . . . . . . . . 10, 20, 30, 40
MaterialsCartridge . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . PVDFSeals . . . . . . . . . . . . . . . Silicone o-rings
Operating ParametersMaximum Temperature . . . . . . . . . . . . . 176°F (80°C) @ 25 psid (1.7 bar)Maximum Differential Pressure @ 25°C 80 psi (5.5 bar)Filtration Rating . . . . . . . . . . . . . . . . . . . 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI biological test for plasticsValidation . . . . . . . . . . . . . . . . . . . . . . . . Quantitative Retention of 107 CFU/cm2 per ASTM methodology
Recommended Water Flow Rates0.2 µm . . . . . . . . . . . . . 1.0 gpm/10" length (3.8 lpm/10" length)
Sanitizing Agents. . . . . . . . . . . . . . . . . . . Chlorine, hydrogen peroxide
Sterilization. . . . . . . . . . . . . . . . . . . 30 SIP cycles of 30 min @ 135˚C; 30 autoclave cycles
of 60 min @ 126˚C
Integrity TestPore Size Minimum Water Diffusional Flow (cc/min)
Bubble Point @ 23˚C @ Test Pressure per 10" length0.2 µm . . . . . . . . . . . . . > 50 psig (> 3.45 bar) < 13.3 @ 40 psig (3.1 bar)
ORDERING INFORMATIONCatalog Number and Description
FCPV . . . . . . . . . . . . . . Filter cartridge pharmaceutical/validated
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30
S2 . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 µm
To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
44
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
PV Series Pleated Hydrophilic PVDF MediaPharmaceutical Grade Filter Cartridge
45
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
VH Series Pleated PES Media Pharmaceutical Grade Filter Cartridge
• Cartridge is a validated, pleated polyethersulphone membrane over a non-woven
polyester support layer
• Code 0, Code 5, Code 7 and Code 10 configurations are available in 10, 20 30,
and 40-in lengths that are 100% tested in manufacturing to ensure absolute
bacteria retention
• Materials conform to the relevant requirements of 21CFR Part 177 and current
USP Plastics Class VI-121˚C and ISO10993 equivalents
• FCVH Series Sterilizing Grade 0.2 micron filters are validated by bacterial challenge
testing to methods specified in ASTM F838-83 (107 organisms/cm2 minimum)
with typical in-house challenge levels being 1011 per 10 inch module for
Brevundimonas diminuta
• Contain no surfactants or coatings to interfere with your application, and the
thermo-plastic construction process minimizes extractables.SPECIFICATIONSDimensionsDiameter (OD). . . . . . . . 2.75" (7.0 cm)Length (in). . . . . . . . . . . 10, 20, 30, 40MaterialsCartridge . . . . . . . . . . . . Polypropylene, core and cage, nylon endcaps
with 316LSS insertSupport . . . . . . . . . . . . . PolyesterMedia . . . . . . . . . . . . . . PolyethersulphoneSeals . . . . . . . . . . . . . . . Silicone o-ringsOperating ParametersMaximum Temperature . . . . . . . . . . . . . 176°F (80°C) @ 29 psid (2.0 bard)Maximum Differential Pressure @ 25°C 72 psi (5.0 bar)Filtration Rating . . . . . . . . . . . . . . . . . . . 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI biological test for plasticsValidation . . . . . . . . . . . . . . . . . . . . . . . . Microbially retentive and validated to ASTM F838-83
methodologyRecommended Water Flow Rates0.1 µm . . . . . . . . . . . . . 1.8 gpm/10" length (2.3 lpm/10" length)0.2 µm . . . . . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)0.45 µm . . . . . . . . . . . . 3.0 gpm/10" length (11.4 lpm/10" length)Sanitizing AgentsChlorine, hydrogen peroxide, autoclaved for 20 minutes at 121°C under no load conditions.SterilizationFCVH cartridges can be repeatedly in-situ steam sterilized or autoclaved up to 130˚C (266˚F). They can besanitized with hot water at up to 90˚C (194˚F) and are compatible with a wide range of chemicals.Integrity TestPore Size . . . . . . . . . . . . . . . . Minimum Water Diffusional Flow (cc/min)
Bubble Point @ Test Pressure per 10" length0.1 µm . . . . . . . . . . . . . . . . . . ≥ 34.2 psig* ≤ 27 @ 70 psig (4.9 bar)0.2 µm . . . . . . . . . . . . . . . . . . ≥ 49 psig ≤ 16 @ 40 psig (2.7 bar)0.45 µm . . . . . . . . . . . . . . . . . ≥ 36 psig ≤ 16 @ 25 psig (1.7 bar)* 60/40 IPA water test solution
ORDERING INFORMATIONCatalog Number and DescriptionFCVH . . . . . . . . . . . . . . Filter cartridge pharmaceutical/validatedX . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings
1 = single open end w/internal o-ring5 = 2-222 o-rings w/spear end7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40XX . . . . . . . . . . . . . . . . . Micron Rating: S1 = 0.1 µm, S2 = 0.2 µm, S4 = 0.45 µm
To determine your catalog order number, replace the X with one of the numbered or lettered options beside it.Note: Not all part number combinations are available; consult Technical Support for assistance.
• Composed of validatable hollow fiber polysulfone media with polypropylene
hardware
• These absolute rated filters offer excellent bacteria, particle and pyrogen removal
for critical pharmaceutical and life science applications, at economical costs
• Code 0, Code 5, and Code 7 configurations are available in 10, 20, 30 and
40-in lengths
• Meet current USP Class VI biological test for plastics, with a validation
certificate available
• Contain no surfactants or coatings to interfere with your application, and
thermo-plastic construction process minimizes extractables
• Hollow fiber construction ensures strength, while exhibiting low pressure drop
and exceptionally high flow rates
• Multi-tube applications require special housings - contact Technical Support
SPECIFICATIONSDimensions
Diameter (OD). . . . . . . . 2.9" (7.4 cm)Length (in). . . . . . . . . . . 10, 20, 30, 40
Materials
Cartridge . . . . . . . . . . . . Polypropylene caps and cage, polyurethane end sealantMedia . . . . . . . . . . . . . . Polysulfone fibersSeals . . . . . . . . . . . . . . . Silicone o-rings
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . 185°F (85°C) @ 10 psid (.7 bar)Maximum Differential Pressure . . . . . . . 30 psi (2 bar) @ 25°CFiltration Rating . . . . . . . . . . . . . . . . . . . 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI biological test for plasticsValidation . . . . . . . . . . . . . . . . . . . . . . . . Diffusive flow test methods
Recommended Water Flow Rates
0.05 micron . . . . . . . . . . 2.0 gpm/10" length (7.6 lpm/10" length)0.1 and 0.2 micron . . . . 3.0 gpm/10" length (11.4 lpm/10" length)
Sanitizing Agents
. . . . . . . . . . . . . . . . . . . Chlorine, hydrogen peroxide, autoclaved for 20 minutes
. . . . . . . . . . . . . . . . . . . at 121°C under no load conditions
ORDERING INFORMATIONCatalog Number and Description
FCUF . . . . . . . . . . . . . . Filter cartridge ultra filter
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end1 = single open end w/ internal o-ring7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40
XX(X) . . . . . . . . . . . . . . Micron Rating: S05 = 0.05 µm, S1 = 0.1 µm, S2 = 0.2 µm
To determine your catalog order number, replace the X with one of the numbered or lettered options beside it. Note: Notall part number combinations are available; consult Technical Support for assistance.
46
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - PARTICULATE
UF Series Hollow Fiber Polysulfone MediaFilter Cartridge
47
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
316 Stainless Steel, Single-Tube Filter HousingFor Code F
This single-tube cartridge filter housing is made of cast 316 stainless steel and
includes 316 stainless steel shell. Housings are available to accommodate 10, 20
or 30-in Code F filter cartridges. The inlet and outlet are 3/4" NPT, and the bowl
of each housing is fitted with a 1/4" NPT drain plug. This cartridge filter housing
is ideal for a wide variety of low flow applications requiring a high quality prefilter
housing or for applications where an industrial pre-filter is used.
• Single tube housings accommodate 10", 20" and 30" Code F filter cartridges
• Housing uses 316SS for construction of the head, bowl and port plug
• Inlet and outlet connections are made to the housing head, allowing cartridges
to be replaced without disconnecting the inlet/outlet piping
• Housing can be autoclaved or hot-water sanitized with the cartridges in place
for your convenience
SPECIFICATIONSDimensions
Length (A) Width (B)
10-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.5" (34.3 cm) 4.75 (12.1 cm)20-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.5" (59.7 cm) 4.75 (12.1 cm)30-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33.5" (85.1 cm) 4.75 (12.1 cm)
Materials
Bowl and Head . . . . . . . . . . . . . . . . . . . 316 stainless steelPort Plugs . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steelO-ring. . . . . . . . . . . . . . . . . . . . . . . . . . . Ethylene Propylene
Operating Parameters
Max Operating Pressure . . . . . . . . . . . 175 psi (12.1 bar) @ 200°F (93°C)Max Housing Flow Rate . . . . . . . . . . . . 12 gpm (45.4 lpm)Note: Housing rating only, safe operating pressure will depend on filter cartridge and gaskets used.
Connections
Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . . . 3/4" NPTDrain . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" NPT
Mounting
Should be mounted by rigid pipe connections or with optional mounting bracket. Allow enoughclearance below bottom of housing to allow cartridge to be changed.
Flow Direction
“Inlet” and “Outlet” are cast on the housing head for user convenience.
ORDERING INFORMATIONCatalog Number and Description
ZHDFD1001 10" housing
ZHDFD2001 20" housing
ZHDFD3001 30" housing
ZHDXDB001 Mounting Bracket
B10015866 Shell O-ring EPDM
This single-tube cartridge filter housing is made of 316L stainless steel and
includes 316 stainless steel port plugs. Housings are available to accommodate
10, 20 or 30-in Code 0 filter cartridges. The inlet and outlet are 3/4" NPT, and the
bowl of each housing is fitted with a 1/4" NPT drain plug. This cartridge filter
housing is ideal for a wide variety of low flow applications requiring a high
quality prefilter housing or for applications where an industrial pre-filter is used.
• Inlet and outlet connections are made to the housing head, allowing cartridges
to be replaced without disconnecting the inlet/outlet piping
• Bowl incorporates a satin finish to help prevent bacterial build-up
• Housing can be autoclaved or hot-water sanitized with the cartridges in place
for your convenience
• Two vent ports are included in the head for venting, or for the installation of
pressure gauges
SYSTEM SPECIFICATIONSDimensions Length (A) Width (B)10-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.8" (37.5 cm) 4.2 (10.5 cm)20-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24.8" (62.9 cm) 4.2 (10.5 cm)30-in Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34.8" (88.4 cm) 4.2 (10.5 cm)
MaterialsHead . . . . . . . . . . . . . . . . . . . . . . . . . . . 316L stainless steelBowl and Plugs . . . . . . . . . . . . . . . . . . . 316 stainless steelO-ring. . . . . . . . . . . . . . . . . . . . . . . . . . . EPDM
Surface FinishHead . . . . . . . . . . . . . . . . . . . . . . . . . . . Sand Blasted Finish Cartridge Sealing Surface . . . . . . . . . . . 32 RMS FinishBowl . . . . . . . . . . . . . . . . . . . . . . . . . . . . Satin Finish
Operating ParametersMax Inlet Pressure . . . . . . . . . . . . . . . . 175 psi (12.1 bar) @ 150°F(66°C)Note: Housing rating only, safe operating pressure will depend on filter cartridge and gaskets used.
ConnectionsInlet/Outlet . . . . . . . . . . . . . . . . . . . . . . . 3/4" NPTDrain and Vent. . . . . . . . . . . . . . . . . . . . 1/4" NPT
MountingShould be mounted by rigid pipe connections or optional mounting bracket. Allow enoughclearance below bottom of housing to allow cartridge to be changed.
Flow Direction“Inlet” and “Outlet” are electroetched on the housing head for user convenience.
ORDERING INFORMATIONCatalog Number and Description
ZHD0D1001 10" housing
ZHD0D2001 20" housing
ZHD0D3001 30" housing
ZHDXDB001 Mounting Bracket
B10015866 Shell O-ring EPDM
48
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
316L Stainless Steel, Single-Tube Filter HousingFor Code O
49
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
316L Electropolished Stainless Steel, Multi-Tube Filter HousingFor Code 5 or Code O
This multi-tube cartridge filter housing is made of electropolished 316L stainless steel.
Housings are available to accommodate 7 cartridges in 10, 20, 30 or 40" length, Code 5
or Code 0 configurations with two 222 o-rings. The bottom of each housing is fitted with
a 3/4" NPTF drain plug. And each housing is equipped with a NPTF vent at the top of the
housing. A V-band clamp closure allows cartridges to be changed quickly and easily.
• Housing uses electropolished 316L stainless steel construction that is easy to clean and
provides maximum corrosion resistance
• Predrilled support stand allows the housing to be secured to floor or some mounting
surface
• A 1/4" NPTF air vent plug on the cover allows venting before start-up
FILTER HOUSING SPECIFICATIONSDimensions Inlet/Outlet Housing Dimensions Flange Option Max. Flow
(inches (cm) A B C D E Rate*/gpm (lpm)
7-round 10" 2" NPTM (5.1) 25 (64) 11.5 (29) 5.5 (14) 12 (30) 12.8" (32) 35 (132)7-round 20" 2" NPTM (5.1) 33.5 (85) 11.5 (29) 5.5 (14) 12 (30) 12.8" (32) 70 (264)7-round 30" 2" NPTM (5.1) 44 (112) 11.5 (29) 5.5 (14) 12 (30) 12.8" (32) 105 (398)7-round 40" 2" NPTM (5.1) 54.5 (138) 11.5 (29) 5.5 (14) 12 (30) 12.8" (32) 140 (530)
Materials
Head and Shell . . . . . . . . . . . . . . . . . . . 316L Stainless Steel electropolishedVent and Drain Plug . . . . . . . . . . . . . . . 316 Stainless Steel Seat Cups . . . . . . . . . . . . . . . . . . . . . . . 316L Stainless SteelO-Ring . . . . . . . . . . . . . . . . . . . . . . . . . . Ethylene Propylene
Operating Parameters
Maximum Operating Pressure . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C)Maximum Water Flow Rate* . . . . . . . . . 140 gpm (528 Lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
ORDERING INFORMATIONCatalog Number Description Inlet/Outlet
ZHH000710 7-round 10" 2" NPTM
ZHH000720 7-round 20" 2" NPTM
ZHH000730 7-round 30" 2" NPTM
ZHH000740 7-round 40" 2" NPTM
ZHH000710F 7-round 10" 2" flange
ZHH000720F 7-round 20" 2" flange
ZHH000730F 7-round 30" 2" flange
ZHH000740F 7-round 40" 2" flange
B10016248 Spare Housing O-RingEPDM
This multi-tube cartridge filter housing is made of 316L stainless steel, and suited
to high purity and sanitary applications. These housings include options to
accommodate Code 0 and 5 or Code 7 filter cartridges.
• High quality, crevice free construction
• External mirror polished, internally polished to 32 Ra–EP option
• Steam sterilizable
• Sanitary Tri-Clamp, vent and drain connections
• Band clamp or Rathmann style screw clamp (used on 12, 18, 24 and 30
round vessels) body closure as standard for additional security
• Inlet/outlet available with Tri-Clamp (below) or ANSI flange connections
• Available in Code 0 and 5 (below) or optional Code 7 end cap configuration
PRODUCT SPECIFICATIONSHead and Shell . . . . . . . . . . . . . . . . . . . 316L Stainless SteelSeals . . . . . . . . . . . . . . . . . . . . . . . . . . . SiliconeSurface Finish . . . . . . . . . . . . . . . . . . . . Internal: mechanical polish 32Ra
External: mechanical polish, EP optionCartridge Configuration . . . . . . . . . . . . . Code 0 and 5, Code 7 optionMaximum Operating Pressure . . . . . . . 3–8 Round:145 psig @ 104˚F
12 Round: 130.5 psig @ 104˚FMaximum Operating Temperature . . . . . 3–8 Round: 302˚F @ 108.75 psig
12 Round: 302˚F @ 101.50 psig
ORDERING INFORMATIONPart Number Cartridge A (in) B (in) C (in) D (in) E (in) Total Total
No. Length Dia. X-port Pipe Dia. Overall Required Volume NetHeight Clearance (L) Weight (kg)
ZHHP0N0320T 3 20 6.6 14.2 1–1/2" 41.3 21.3 12.6 19.4ZHHP0N0330T 3 30 6.6 14.2 1–1/2" 51.2 31.1 17.8 21.4ZHHP0N0520T 5 20 8.6 16.5 2" 41.3 21.3 20 20ZHHP0N0530T 5 30 8.6 16.5 2" 51.2 31.1 29.1 22ZHHP0N0820T 8 20 10.7 17.6 2" 41.3 21.3 35.5 30ZHHP0N0830T 8 30 10.7 17.6 2" 51.2 31.1 49.7 33ZHHP0N1220T 12 20 13.8 26.9 3" 47.2 21.3 65 14.5ZHHP0N1230T 12 30 13.8 26.9 3" 57.1 31.1 88 19
ZHHP 3/5/8 Round
ZHHP 12 Round
Vessel Size Tri-Clamp Size (in) Flange Size (in)3 round 1-1/2" 1-1/4"5 round 2" 1-1/2"8 round 2" 1-1/2"12 round 3" 3"
50
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
316L Stainless Steel, Multi-Tube High PurityHousingFor Code 0 and Code 5, option for Code 7
51
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
316 Stainless Steel, Multi-Tube Filter HousingFor Code F
This multi-tube cartridge filter housing is made of 316 stainless steel, and is
suited for general-purpose industrial and commercial filtration. These housings
can accommodate Code F (DOE) or Code 0 cartridges, and are available with 6,
12, and 21 tubes in 10, 20, 30, 40-inch lengths.
• Incorporates a flow baffle, which deflects incoming flow to prevent cartridge
erosion
• An air vent on the cover allows venting before start-up
• A swing bolt closure allows quick disassembly for cleaning and cartridge
replacement
6-ROUND DIMENSIONS 12- AND 21-ROUND DIMENSIONS
FILTER HOUSING SPECIFICATIONS
Dimensions Inlet/Outlet Housing Dimensions Flange Option Max. Flow(inches (cm) A B C D E Rate*/gpm (lpm)
6-round 10” 2 NPTM (5.1) 24 (61) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 30 (114)6-round 20” 2 NPTM (5.1) 34 (86) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 60 (227)6-round 30” 2 NPTM (5.1) 45 (114) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 90 (340)6-round 40” 2 NPTM (5.1) 56 (142) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 120 (454)12-round 30” 3 flange (7.6) 56 (142) 31 (79) 12 (30) 12 (30) 16.4 (42) 180 (680)12-round 40” 3 flange (7.6) 66 (168) 31 (79) 12 (30) 12 (30) 16.4 (42) 240 (908)21-round 30” 4 flange (10.16) 57 (145) 31 (79) 12 (30) 16 (41) 20.8 (53) 315 (1190)21-round 40” 4 flange (10.16) 67 (170) 31 (79) 12 (30) 16 (41) 20.8 (53) 420 (1560)
Materials
Head, Shell, Plugs . . . 316L Stainless SteelInternals . . . . . . . . . . . 316 Stainless SteelCover O-Ring. . . . . . . EDPM
Maximum Operating Pressure
6-Round. . . . . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C)12-Round. . . . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C)21-Round. . . . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C)
ORDERING INFORMATION
Catalog Number Description Inlet/Outlet
ZHGOF0610 6-round 10" 2" NPT
ZHGOF0620 6-round 20" 2" NPT
ZHGOF0630 6-round 30" 2" NPT
ZHGOF0640 6-round 40" 2" NPT
ZHGOF0610F 6-round 10" 2" flange
ZHGOF0620F 6-round 20" 2" flange
ZHGOF0630F 6-round 30" 2" flange
ZHGOF0640F 6-round 40" 2" flange
ZHFFI1230 12-round 30" 3" flange
ZHFFI1240 12-round 40" 3" flange
ZHFFI2130 21-round 30" 4" flange
ZHFFI2140 21-round 40" 4" flange
B10020279 Replacement O-ring EPDM -6-round
B10015430 Replacement O-ring EPDM -12-round
*Housing rating only, cartridge length and type will effect maximum flow rates
52
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
316 Stainless Steel, Multi-Tube Filter Housing
53
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
304 Stainless Steel, Multi-Tube FilterHousing with V-Clamp ClosureFor Code F
FILTER HOUSING SPECIFICATIONSCartridge Inlet/Outlet Housing Dimensions/Inches (cm) Flange Opt. Max. FlowHousing Inches (cm) A B C D E Rate*/gpm (lpm)
5-round 10" 1-1/2 NPTM (3.8) 25 (64) 11.5 (29) 5.5 (14) 12 (30) 12.75 (32) 25 (94.6)5-round 20" 1-1/2 NPTM (3.8) 32.5 (85) 11.5 (29) 5.5 (14) 12 (30) 12.75 (32) 50 (189)5-round 30" 2 NPTM (5.1) 44 (112) 11.5 (29) 5.5 (14) 12 (30) 12.75 (32) 75 (284)5-round 40" 2 NPTM (5.1) 54.5 (138) 11.5 (29) 5.5 (14) 12 (30) 12.75 (32) 100 (378)
Materials
Head, Shell, Plugs. . . . . . . . . . . . . . . . . 304 Stainless SteelInternals . . . . . . . . . . . . . . . . . . . . . . . . . 316 Stainless SteelCover O-Ring. . . . . . . . . . . . . . . . . . . . . Ethylene PropyleneHold Down Plate Nut . . . . . . . . . . . . . . . Polypropylene
Operating Parameters
Maximum Operating Pressure. . . . . . . . 150 psi (10.7 bar) @ 200°F (93°C)Maximum Housing Flow Rates* . . . . . . 100 gpm (378 lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
ORDERING INFORMATIONCatalog Number Description Inlet/Outlet
ZHFFI0510 5-round 10" 1-1/2" NPT
ZHFFI0520 5-round 20" 1-1/2" NPT
ZHFFI0530 5-round 30" 2" NPT
ZHFFI0540 5-round 40" 2" NPT
ZHFFI0510F 5-round 10" 1-1/2" Flange
ZHFFI0520F 5-round 20" 1-1/2" Flange
ZHFFI0530F 5-round 30" 2" Flange
ZHFFI0540F 5-round 40" 2" Flange
B10016248 Spare Housing O-RingEPDM
**Flange inlet and outlet are also available; add F Suffix to part number
This multi-tube cartridge filter housing is made of durable 304 stainless steel, and is
suited for general-purpose industrial and commercial filtration. These housings can
accommodate Code F (DOE, internals provided), and can be configured for Code 0
and Code 5 cartridges.
• Incorporates a flow baffle, which deflects incoming flow to prevent cartridge erosion
• A 1/4" NPT air vent on the cover allows venting before start-up
• A 3/4" NPT drain plug allows for liquid removal
• Cartridges are independently sealed inside the housing and a single V-band clamp
housing closure allows easy cartridge replacement
• Cartridge post can be lifted out, allowing easy removal of cartridges at the bottom
of the stack
FILTER HOUSING SPECIFICATIONSCartridge Housing Dimensions/Inches (cm) Flange Opt. Max. FlowHousing A B C D E Rate*/gpm (lpm)
6-round 10" 24 (61) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 30 (114)6-round 20" 34 (86) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 60 (227)6-round 30" 45 (114) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 90 (340)6-round 40" 56 (142) 11.2 (28) 5.2 (13) 10.2 (26) 15 (38) 120 (454)
Materials
Head and Shell . . . . . . . . . . . . . . . . . . . 304 Stainless SteelVent and Drain Plug . . . . . . . . . . . . . . . 304 Stainless Steel Seat Cups . . . . . . . . . . . . . . . . . . . . . . . 316L Stainless SteelO-Ring . . . . . . . . . . . . . . . . . . . . . . . . . . Ethylene Propylene
Operating Parameters
Maximum Operating Pressure . . . . . . . 150 psi (10.3 bar) @ 200°F (93°C)Max Water Flow Rate*. . . . . . . . . . . . . . 120 gpm (454 Lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
ORDERING INFORMATIONCatalog Number Description Inlet/Outlet
ZHGAF0610 6-round 10" 2" NPT
ZHGAF0620 6-round 20" 2" NPT
ZHGAF0630 6-round 30" 2" NPT
ZHGAF0640 6-round 40" 2" NPT
ZHGAF0610F 6-round 10" 2" flange
ZHGAF0620F 6-round 20" 2" flange
ZHGAF0630F 6-round 30" 2" flange
ZHGAF0640F 6-round 40" 2" flange
B10020279 Spare Housing O-ring
This multi-tube cartridge filter housing is made of 18 gauge 304 stainless steel.
Housings are available to accommodate 6, 10, 20, 30 or 40-in, Code F filter
cartridges. The inlet and outlet are 2" NPT. There is a 1/2" NPT drain plug, and a
1/4" NPT vent at the top of the housing. A swing bolt closure allows quick
disassembly for cleaning and service. This cartridge filter housing is ideal for a
wide variety of high flow applications that require an economical, high quality
housing.
• Uses 304 stainless steel construction for maximum corrosion resistance to deliver
years of dependable service
• A swing bolt closure allows quick disassembly for cleaning and service
• An air vent plug on the cover allows venting before start-up
• This housing accommodates liquid flow rates up to 180 gpm (681 lpm) with
operating pressures to 150 psig (10.3 bar)
54
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
304 Stainless Steel, Multi-TubeFilter Housing with Swing Bolt ClosureFor Code F
55
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
Polypropylene Plastic Filter Housings
These filter housings are molded from polypropylene, and are available in 10 and 20
inch lengths. Housings are supplied with 3/4" inlet and outlets in standard flat gasket
design for Code F filter cartridges. Heads are available with double cap plug design
and Viton® o-rings.
• Durable housings are made from all polypropylene materials
• Housings contain no fillers, colorants, plasticizers, or lubricants
• Housings are autoclavable, ETO sterilizable, and hydrogen peroxide compatible
• Supplied with 3/4" NPT inlet and outlets in standard flat gasket design for Code F
filter cartridges
FILTER HOUSING SPECIFICATIONS
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5" ID, 5 1/8” OD maximumMaterials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . polypropylene cap and housing with standard
Viton® E-60 o-ringsMaximum Operating Pressure . . . . . . . . . . . . . . . . . . . . 125 psi (8.6 bar)Maximum Operating Temperature . . . . . . . . . . . . . . . . . 100°F (38°C)Sterilization/Sanitization
Hydrogen Peroxide . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5% compatibility; static soak up to 24 hr at ambient temperature
Weight10" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 lb (1.4 kg)20" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 lb (1.9 kg)
Housing Compatibility/Cartridge TypeZHCFA1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code F, 9 3/4”ZHCFA2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code F, 20”
ORDERING INFORMATION
Catalog Number: ZHC F A XX XX
PolypropyleneSystem Name. . . . . . . . . . . . . filter housingCartridge Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F = Code FCartridge Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A = No plugs 10 = 10Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 = 20Number of Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 = 1 tube
To figure your order number, replace the X with one of the numbered options below it.
ACCESSORIES
Description Catalog Number
Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHA150060Wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FC150295O-ring replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHA151021
FILTER HOUSING SPECIFICATIONS
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5" ID, 5 1/8” OD maximumMaterials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . White colored polypropylene cap and housing with
standard Viton® E-60 o-ringsMaximum Operating Pressure . . . . . . . . . . . . . . . . . . . . 100 psi (6.9 bar)Maximum Operating Temperature . . . . . . . . . . . . . . . . . 100˚ F (35˚C)Sterilization/Sanitization
Hydrogen Peroxide . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5% compatibility; static soak up to 24 hr at ambient temperature
Weight12" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 lb (1.6 kg)20" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 lb (1.9 kg)
Housing Compatibility/Cartridge TypeZHW0D1201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 0, 10"ZHW0D2001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 0, 20"
ORDERING INFORMATION
Catalog Number: ZHW X X XX XX
Whitepolypropylene
System Name. . . . . . . . . . . . . filter housingCartridge Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 = Code 0Housing Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D = Double cap plug 12 = 12Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 = 20Number of Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 = 1 tube
To figure your order number, replace the X with one of the numbered/lettered options below it.
ACCESSORIES
Description Catalog Number
Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHA150060O-ring Viton® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHA151117
These filter housings are molded from a white colored, high-density polypropylene,
and are available in 12 and 20 inch lengths to accommodate 10 and 20 inch Code 0
filter cartridges. Housings are molded in dies that are minutely polished for an
ultra-smooth finish to all contact surfaces, thus minimizing the opportunity for
bacteria adhesion. Housings are supplied with 3/4" inlet and outlets. Heads are
available with double cap plug design and Viton® o-rings.
• Durable housings are made from all polypropylene materials with FDA approved
white colorant
• O-rings are molded of FDA approved Viton®
• Available in 222 o-ring design for Code 0 filter cartridges
• Housings are hydrogen peroxide compatible
• Supplied with 3/4" NPT inlet and outlets
56
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
White Polypropylene Plastic Filter Housingfor Dialysis Filtration Applications
57
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - HOUSING
Natural Polypropylene Plastic FilterHousing
These filter housings are molded from natural, high-density polypropylene, and is
available in 10, 12 and 20 inch lengths. Housings are molded in dies that are minutely
polished for an ultra-smooth finish to all contact surfaces, thus minimizing the
opportunity for bacteria adhesion. Housings are supplied with 3/4" inlet and outlets in
standard flat gasket design for Code F filter cartridges, and 222 o-ring design for Code 0
filter cartridges. Heads are available with double cap plug design and Viton® o-rings.
• Durable housings are made from all polypropylene materials (except for o-rings)
• Housings contain no fillers, colorants, plasticizers, or lubricants
• Available in flat gasket design for Code F filter cartridges, and 222 o-ring design for
Code 0 filter cartridges
• Housings are autoclavable and hydrogen peroxide compatible
• Supplied with 3/4" NPT inlet and outlets
FILTER HOUSING SPECIFICATIONS
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5" ID, 5 1/8” OD maximumMaterials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Natural polypropylene cap and housing with
standard Viton® E-60 o-ringsMaximum Operating Pressure . . . . . . . . . . . . . . . . . . . . 100 psiMaximum Operating Temperature . . . . . . . . . . . . . . . . . 38° C (100°F)Sterilization/Sanitization
Autoclavable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 min 121-127°C (252-260°F)Hydrogen Peroxide . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5% compatibility; static soak up to 24 hr at
ambient temperature Weight
10" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 lb (1.4 kg)12" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 lb (1.6 kg)20" housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 lb (1.9 kg)
Housing Compatibility/Cartridge TypeZHA0D1201* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 0, 10"ZHA0D2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 0, 20"ZHAFD1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code F, 9 3/4"ZHAFD2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code F, 20"
*Code 0, 10" cartridge must be used with 12" housing*Code 0 cartridge requires 12" housing
ORDERING INFORMATION
Catalog Number: ZHA X X XX XX
Naturalpolypropylene
System Name. . . . . . . . . . . . . filter housing F = Code FCartridge Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 = Code 0 10 = 10Housing Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D = Double cap plug 12 = 12Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 = 20Number of Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 = 1 tube
To figure your order number, replace the X with one of the numbered/lettered options below it.
*Code 0 cartridge requires 12" housing
ACCESSORIES
Description Catalog Number
Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHA150060O-ring Viton® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZHA151117
CARTRIDGE SPECIFICATIONS
Dimensions
Diameter (OD) . . . . . . . . . . . . . . . . . . 2.75" (7.0 cm ) or 4.5" (11.7 cm )Length . . . . . . . . . . . . . . . . . . . 9.75", 10", 20", 30", 40”
Materials
Media . . . . . . . . . . . . . . . . . . . . . Modified CelluloseCore . . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene Gaskets . . . . . . . . . . . . . . . . . . . . . Buna N
Operating Parameters
Max. Temperature . . . . . . . . . . . . 120° F (50° C)Max. Differential Pressure . . . . . . . . 36 psi (2.5 bar) @ 25°C
Recommended Water Flow Rates
2.75" Diameter . . . . . . . . . . . . . . . . . 5.0 gpm/10" Length (18.9 lpm/10" Length)4.60" Diameter . . . . . . . . . . . . . . . . 5.0 gpm/10" Length (18.9 lpm/10" Length)
ORDERING INFORMATION
Catalog Number: HAC X X XX X X
Hydrocarbon Adsorption Cartridge . HAC 09 = 9.75A = 2.75" 0 = 2-222 O-Rings 10 = 10
Cartridge Diameter . . . . . . . . . . . . . . . . . . . . B = 4.5" F = Double open end 20 = 20Cartridge Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . w/flat gasket seals 30 = 30Length (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 = 40Core Material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P = PolypropyleneGasket Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B = Buna N
• Composed of sheets of modified cellulose material rolled on a central
polypropylene support core
• Removes 95% of total hydrocarbons from water in a single pass. The media
can adsorb up to 300% of its own weight in oils
• Available in 2.75" and 4.6" diameters and lengths to 40"
58
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - SPECIALTY CARTRIDGE
CLERIFY™ Oil Adsorption Filter Cartridge
CARTRIDGE FILTER - VENT FILTER
Hydrophobic PTFE Media Vent Capsule Filter
• Composed of a pleated hydrophobic PTFE filter membrane rated at 0.01 µm
absolute for small volume storage tank venting applications
• Convenient threaded inlet, with 1/2" NPTM inlet fitting screws into 1/2" NPTF
bulkhead fitting, eliminates the need for a filter housing
• Hydrophobic expanded PTFE membranes are fully validated by bacterial
challenge test methods
• Filters feature thermally-bonded polypropylene cage without using adhesives to
ensure low extractables
• 100% integrity tested in manufacturing and can be repeatedly autoclaved with
steam up to 140°C
CARTRIDGE SPECIFICATIONS
Dimensions
Diameter (OD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.48" (5.6 cm)Length (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9 (15 cm)Inner Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2" NPTM
Materials
Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PTFE Membrane
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . . . . . . . . 60˚C (140˚F)Maximum Differential Pressure @ 80°C (176˚F) . . . . 65 psig (4.5 bar)Air Filtration Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01 µm 100% Absolute
ORDERING INFORMATION
Catalog Number and Description
FCVPTO6S1 Capsule Hydrophobic PTFE Filter
NOTE: These filter cartridges should not be used as a combination air vent/water overflow device.
59
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
• Composed of a pleated hydrophobic highly asymmetric polysulfone membrane
rated at 0.02 µm absolute for sterile air filtration, storage tank venting applications
• Filter components meet current USP Class VI biological test for plastics
• Contain no surfactants or coatings to interfere with your application, and the
thermo-plastic construction process minimizes extractables
• Asymmetric single layer membrane ensures strength, while exhibiting low pressure
drop and exceptionally high flow rates
• Sterilized by autoclaving
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD). . . . . . . . 2.6" (6.6 cm)Length (in). . . . . . . . . . . 10, 20, 30
Materials
Cartridge . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . Hydrophobic asymmetric polysulfoneSeals . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . Ambient AirMaximum Differential Pressure @ 23°C 60 psi (4.1 bar)Air Filtration Rating . . . . . . . . . . . . . . . . 0.02 µm 100% AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . Non-toxic by USP Class VI biological test for plasticsSanitizing Agents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chlorine, hydrogen peroxide or autoclaving
ORDERING INFORMATIONCatalog Number and Description
FCEA . . . . . . . . . . . . . . Filter cartridge vent polysulfone
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end1 = single open end w/internal o-ring7 = 2-226 o-rings w/locking tabs/spear endF = double open end w/flat gasket seal
XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30
S2 . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.02 µm (air)
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not allpart number combinations are available; consult Technical Support for assistance.
NOTE: These filter cartridges should not be used as a combination air vent/water overflow device.
60
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - VENT FILTER
EA Series Hydrophobic Polypropylene Media Vent Filter Cartridge
61
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CARTRIDGE FILTER - VENT FILTER
VA Series Hydrophobic PTFE ValidatedMembrane Vent Filter Cartridge
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD). . . . . . . . 2.6Length (in). . . . . . . . . . . 5, 10, 20, 30
Materials
Cartridge . . . . . . . . . . . . Polypropylene caps, core and cageMembrane. . . . . . . . . . . Hydrophobic PTFESeals . . . . . . . . . . . . . . . Silicone o-rings
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . 50˚ CMaximum Differential Pressure @ 20°C 50 psigAir Filtration Rating . . . . . . . . . . . . . . . . 0.02 µm AbsoluteToxicity . . . . . . . . . . . . . . . . . . . . . . . . . . All components conform to the Biological Safety Standards
identified in USP <88> Biological Reactivity to Class VI-121˚C levelsValidation . . . . . . . . . . . . . . . . . . . . . . . . ASTM F838-83 Liquid Bacterial Challenge
Fully retentive to both Aerosol Bacteria and Phage Challenge
Sanitizing Agents
Sterilization . . . . . . . . . . . . . . . . . . . . . . Can be insitu steam sterilized up to 180 times at 142˚C. . . . . . . . . . . . . . . . . . . Chlorine, hydrogen peroxide
Integrity Test @ 20˚C
Micron Rating . . . . . . . . 0.2 µm liquid ratingMinimum Bubble Point (psi) 14.5Pressure Decay Test Pressure (psi) 11.6Maximum Diffusional Flow (ml/min) 8.5, 18, 36, 54
ORDERING INFORMATIONCatalog Number and Description
FCVA. . . . . . . . . . . . . . . Filter Cartridge Vent PTFE
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . Length (in): 05 = 5, 10 = 10, 20 = 20, 30 = 30
S2 . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 µm
To figure your order number, replace the X with one of the numbered or lettered options beside it.
NOTE: These filter cartridges should not be used as a combination air vent/water overflow device.
NOTE: Not all part number combinations are available; consult Technical Support for assistance.
• Hydrophobic, pleated PTFE membrane rated at 0.2µm absolute for sterile air filtration
• Materials of construction conform to USP Class VI biological tests for plastics
• High surface area and high voids volume combine to offer exceptional flow rates and
extended service life
• Fully validated by aerosol and liquid bacterial challenge
• Filters are integrity testable by all methods including Water Intrusion Test
• FCVA Series is fully retentive to aerosolized Brevundimonas diminuta (ATCC 19146)
bacteria when challenged with a total of 2x109 cfu over a 1-hr test at the rated flow
of the cartridge.
• Conformance to the requirements for the non-fibre releasing filters as laid down in
the U.S. Food and Drug Administration Regulations 12CFR211.72 and 210.3(b), (6).
62
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE FILTER - VENT FILTER
VP Series Hydrophobic PTFE ValidatedMedia Vent Filter Cartridge
• Composed of a pleated, hydrophobic, PTFE, Teflon® membrane rated at 0.2 µm
absolute for sterile air filtration, storage tank venting applications
• Filter components meet the criteria of the USP Class VI biological test for plastics
• These filters feature minimal pressure loss, long service life due to high void
volume, and can be repeatedly steam sterilized or autoclaved
• Bacterial Growthrough - Prevention of bacterial grownthrough by Brevundimonas
diminuta for at least 21 days @ a challenge level ≥ 1 x 107 CFU/cm2
CARTRIDGE SPECIFICATIONSDimensions
Diameter (OD) . . . . . . . . . . . . . . . . 2.6" (6.6 cm)Length (in) . . . . . . . . . . . . . . . . 10, 20, 30
Materials
Cartridge . . . . . . . . . . . . . . . . Polypropylene caps, core and cageMedia . . . . . . . . . . . . . . . . Hydrophobic Teflon® PTFESeals . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . Ambient AirMaximum Differential Pressure @ 21°C . . 72 psi (5.0 bar)Air Filtration Rating . . . . . . . . . . . . . . . . 0.2 µm AbsoluteToxicity . . . . . . . . . . . . . . . . Non-toxic by USP Class VI biological test for plasticsVirus Aerosol Retention . . . . . . . . . . . . . . . Retention of a worst case challenge of the model
bacteriophage Φ X–174 was complete at challenge levels at 108 to 1010 virus particles at 1400 sL/min (50scfm) after 50 steam sterilization cycles of 30 minutes at 145˚C.
Sanitizing Agents . . . . . . . . . . . . . . . . Chlorine, hydrogen peroxide, autoclaved for 20 minutes . . . . . . . . . . . . . . . . at 121°C under no load conditions.
Integrity Test
Bubble point @ 23˚C . . . . . . . . . . . . . . . . ≥ 13 psig (≥ 900 mbar) nitrogen with 60/40% IPA/WaterNitrogen Diffusion @ 23˚C . . . . . . . . . . . . . ≥ 45 mL/min @ 690 mbar (10 psig) in 60/40% IPA/Water
ORDERING INFORMATIONCatalog Number and Description
FCVP . . . . . . . . . . . . . . Filter cartridge vent polysulfone
X . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end7 = 2-226 o-rings w/locking tabs/spear end
XX . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30
S2 . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 µm
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all partnumber combinations are available; consult Technical Support for assistance.
NOTE: These filter cartridges should not be used as a combination air vent/water overflow device.
Siemens offers pretreatment chemical addition products to maintain the
performance of Reverse Osmosis (RO) systems, inhibiting fouling and scaling of RO
membranes. Siemens Technical Specialists can assist you in choosing the proper
product and applying these products correctly. Pretreatment chemical addition can
be a cost-effective alternative to other methods of controlling feedwater
chemistry.
Antiscalants/Antifoulants prevent scaling of RO membranes, as well as reduce the
rate of colloidal fouling, including hardness and silica.
Coagulants injected before multimedia filters and directly into clarifiers to improve
filtration of silt, turbidity, particulate matter and colloids.
Dechlorination chemicals include sodium sulfite, sodium bisulfite, or sodium
metabisulfite to remove chlorine prior to reverse osmosis systems.
Chlorination kills and controls bacteria in pretreatment systems.
Cleaner chemicals with either low or high pH properties remove ionic and organic
foulants in the RO membrane.
Disinfectant chemicals, such as peroxyacetic acid and hydrogen peroxide
formulations, are used to sanitize the reverse osmosis systems.
ORDERING INFORMATION
Contact Technical Support at (800) 875-7873 ext. 5000 for assistance in sizing your system, choosing the proper chemical and determining the quantity of chemical required.
SYSTEM SPECIFICATIONS
Pump head . . . . . . . . . PVCFittings . . . . . . . . . . . . . PolypropyleneValve Balls . . . . . . . . . . CeramicLiquifram . . . . . . . . . . . Teflon® faceSeal Rings . . . . . . . . . . Teflon®Connections. . . . . . . . . Liquid end no. 72S–0.5" tube
Liquid end no. 92S–0.375" tubeOutput . . . . . . . . . . . . . 100 psiTank . . . . . . . . . . . . . . . PolyethyleneTank Size (gallons) . . . 35 for 1 gph, 50 for 2.5 and 4 gphLiquid Level Switch . . . Polypropylene housing; PVC float tube;
polypropylene floatFlow Meter Pulsar . . . . Body–bronze; Rotor–polypropyleneElectrical . . . . . . . . . . . 115 V/60 Hz
Standard Chemical Feed System: Pre-kittedChemical feed systems are pre-kitted units with ratings of 1, 2, 4 or 5 gph, andconsist of a metering pump, a storage tank with a liquid level switch and suctiontube shield.
• Available with or without a flow pulsar.
• A flowmeter pulsar is optionally available.
ORDERING INFORMATION
Catalog No. Description
ZWCF40000 4 gph chemical feed system w/outflow meter
ZWCF400FM 4 gph chemical feed system w/flow meter
ZWCF25000 2.5 gph chemical feed system w/outflow meter
ZWCF250FM 2.5 gph chemical feed system w/flow meter
ZWCF10000 1.0 gph chemical feed system w/outflow meter
ZWCF100FM 1.0 gph chemical feed system w/flow meter
63CHEMICAL FEED SYSTEMS AND ACCESSORIES
Antiscalant, Coagulants, Dechlorination,Chlorination, Cleaner and Disinfectants
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
64
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - CHEMICAL FEED SYSTEMS
Standard ChemFeed Systems: Grundfos® Pumps
Siemens offers standard dual-pump feed systems covering common chemicalapplications. The table below lists chemicals and pump configurations availablefor Grundfos® Electronic Metering Pumps. All chemical feed skids are completelyassembled and engineered for easy installation and operation.
Ordering Information
Catalog # Model # Description Capacity Material ofConstruction
SP10701904 GR-16-100-C-V Two pump skid with common inlet/discharge. 15.84 GPD CPVC / Viton®100ml Calibration Cylinder
SP10701987 GR-48-100-C-V Two pump skid with common inlet/discharge. 47.52 GPD CPVC/ Viton®100ml Calibration Cylinder
SP10701999 GR-48-100-C-E Two pump skid with common inlet/discharge. 47.52 GPD CPVC/EPDM250ml Calibration Cylinder
SP10701997 GR-118-250-C-V Two pump skid with common inlet/discharge. 117.6 GPD CPVC/ Viton®250ml Calibration Cylinder
SP10701907 GR-118-250-C-V-D Two pump skid with common inlet/discharge. 117.6 GPD CPVC/ Viton®250ml Calibration Cylinder * w/ Diaphragm Valves and Auto-Vent for Hypo
65
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - CHEMICAL FEED SYSTEMS
Standard ChemFeed Systems: LMI® Pumps
Ordering Information
System Specifications Chemical Catalog # Output / PSI Spare LMI SparePump PartsCatalog # Catalog #
Pump Head Sodium Bisulfite: PVDF /TFE Sodium SB-10-100 10 GPD / 140 PSI AA971-353SI SP-SB-10Polymer: PP/TFE Bisulfite SB-24-100 24 GPD / 110 PSI AA951-393SI SP-SB-24Bleach:PVDF/TFE SB-60-250 60 GPD / 100 PSI B921-393SI SP-SB-60Alum: PVDF/TFE SB-96-500 96 GPD / 100 PSI C921-363SI SP-SB-96Potassium Permanganate: PVDF/TFECaustic: PVDF/TFE Polymer POLY-10-100 10 GPD / 140 PSI AA971-155HV SP-POLY-10Hydrochloric Acid: PVDF/TFE POLY-24-100 24 GPD / 110 PSI AA951-85HV SP-POLY-24Sulfuric Acid: PVDF/TFE POLY-60-250 60 GPD / 100 PSI B921-85HV SP-POLY-60Anti-Scalant: PVDF/TFE POLY-96-500 96 GPD / 100 PSI C921-75HV SP-POLY-96
Connections 1/2" CPVC Bleach SH-10-100 10 GPD / 140 PSI AA971-353HI SP-SH-10SH-10-100 24 GPD / 110 PSI AA951-393HI SP-SH-24
Output 10,GPD / 140PSI SH-60-250 60 GPD / 100 PSI B921-393HI SP-SH-6024GPD / 110PSI SH-96-500 96 GPD / 100 PSI C921-363HI SP-SH-9660GPD / 100PSI96GPD / 100PSI Alum AL-10-100 10 GPD / 140 PSI AA971-353SI SP-AL-10
AL-24-100 24 GPD / 110 PSI AA951-393SI SP-AL-24Control Manual or 4-20 mA AL-60-250 60 GPD / 100 PSI B921-393SI SP-AL-60
AL-96-500 96 GPD / 100 PSI C921-363SI SP-AL-96Electrical 120VAC / 60Hz / 1Ph
Potassium PP-10-100 10 GPD / 140 PSI AA971-353SI SP-PP-10Skid 24" x 36" PE Base Permanganate PP-24-100 24 GPD / 110 PSI AA951-393SI SP-PP-24
PP-60-250 60 GPD / 100 PSI B921-393SI SP-PP-60PP-96-500 96 GPD / 100 PSI C921-363SI SP-PP-96
Caustic CAU-10-100 10 GPD / 140 PSI AA971-353SI SP-CAU-10CAU-24-100 24 GPD / 110 PSI AA951-393SI SP-CAU-24CAU-60-250 60 GPD / 100 PSI B921-393SI SP-CAU-60CAU-96-500 96 GPD / 100 PSI C921-363SI SP-CAU-96
Hydrochloric Acid HCA-10-100 10 GPD / 140 PSI AA971-353SI SP-HCA-10HCA-24-100 24 GPD / 110 PSI AA951-393SI SP-HCA-24HCA-60-250 60 GPD / 100 PSI B921-393SI SP-HCA-60HCA-96-500 96 GPD / 100 PSI C921-363SI SP-HCA-96
Sulfuric Acid SA-10-100 10 GPD / 140 PSI AA971-353SI SP-SA-10SA-24-100 24 GPD / 110 PSI AA951-393SI SP-SA-24SA-60-250 60 GPD / 100 PSI B921-393SI SP-SA-60SA-96-500 96 GPD / 100 PSI C921-363SI SP-SA-96
Anti-Scalant AS-10-100 10 GPD / 140 PSI AA971-353SI SP-AS-10AS-24-100 24 GPD / 110 PSI AA951-393SI SP-AS-24AS-60-250 60 GPD / 100 PSI B921-393SI SP-AS-60AS-96-500 96 GPD / 100 PSI C921-363SI SP-AS-96
Siemens offers standard dual-pump feed systems covering common chemicalapplications. The table below lists chemicals and pump configurations availableusing LMI® Electronic Metering Pumps. All chemical feed skids are completelyassembled and engineered for easy installation and operation.
Spare Parts Kits include (1) Calibration Cylinder, (1) Ball Valve, (1) Pump Spare Parts Kit (Seals, Springs, Ball Checks & Diaphragm).
LMI = Liquid Metronics, Inc.
66
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - CHEMICAL FEED SYSTEMS
Polymer Feed Systems
PolyBlend® PB polymer feed systems provide optimum polymer activation andperformance. The PB Series PolyBlend® systems are economical and easy toinstall and operate. The patent technology and offer proven performance makethe PolyBlend® the benchmark in the industry.
EZ ChemFeed Systems
Siemens offers a variety of chemical feed and control systems to meet therequirements of harsh industrial applications. From simple EZ Series pump skids andaccessories to complex systems, Siemens has the ChemFeed solution for your watertreatment needs.
Ordering Information
PolyBlend® PB Series Polymer Feed SystemsCatalog # Water Flow Diaphragm Pump
Rate GPH Output GPHPB16-0.4 16 0.4PB100-1.0 100 1.0PB200-2.0 200 2.0
Ordering Information
Standard EZ Chemical Feed Systems & AccessoriesCatalog # Model # DescriptionCFSEZ1 EZ-1 Pump System The EZ1 Pumps System is a skid-mounted chemical metering system designed for maximum reliability and
convenience. The EZ1 package utilizes LMI® pumps providing a broad range of capabilities EZ1 Systems are typically used in water treatment programs to dose proper amounts of inhibitors, dispersants, biocides, as well as pH control chemicals and oxidants. The system comes complete and ready for service upon delivery
CFSEZ2 EZ-2 Pump System The EZ2 Dual Pump Skid System is a skid-mounted chemical metering system designed to feed either one or two chemicals together or separately. The EZ2 package utilizes LMI® pumps providing a broad range of capacities and flexibility to handle a wide range of applications. EZ2 Systems are typically used in water treatment programs to dose proper amounts of inhibitors, dispersants, biocides, as well as pH control chemical and oxidants.
CFSEZENCLOSURE EZ -Enclosure The EZ Enclosure is a high-quality NEMA 12 fiberglass enclosure, which is ideal for a number of chemical treatment applications. These units are used for dual biocide applications where containment is important.
CFSDRUMSHELF EZ- Drum Shelf The EZ Drum Shelf is designed to secure a metering pump atop a metal or plastic 55-gallon drum. The unit, constructed of 1/2 inch PVC, prevents pumps from tipping over.
At the center of the PolyBlend® PB Seriespolymer feed system is the patented multi-zone mixing chamber. The advanced designprovides uniform dispersion energy at themoment of initial wetting. The high-energymix prevents agglomerations and eliminatesthe need for extended mixing and aging byapplying the right energy at the right time.The low energy zone continues to activatethe hydrated polymer without destroyingthe fragile polymer chains. The result ismaximum polymer activation and improvedpolymer performance.
67
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS
Chem-Tech® Chemical Metering Pumps
The Chem-Tech® pump combines proven degassing technology with thedurability and dependability that has earned Chem-Tech® pumps the respect ofwater treatment professionals around the world. The result is a series of positivedisplacement diaphragm metering pumps that are totally self-priming andmaintain their prime even in the most demanding water conditioning and watertreatment applications.
Ordering Information
Chem-Tech Prime Performance™ PumpsCatalog # GPH PSI Head & Fittings KOP Kit Catalog #X015-XA-BAA8XXX 15 100 PVC / Hypalon KX100-BAA8X015-XA-BBA8XXX 15 100 PVC / Viton KX100-BBA8X024-XA-BAA8XXX 24 100 PVC / Hypalon KX100-BAA8X024-XA-BBA8XXX 24 100 PVC / Viton KX100-BBA8X030-XA-BAA8XXX 30 100 PVC / Hypalon KX100-BAA8X030-XA-BBA8XXX 30 100 PVC / Viton KX100-BBA8
Catalog # GPH PSI TubingSeries CTP-A Simplex (Peristaltic Pumps)
CTPA2HSA-PAP1-XXXXX 3.5 125 NorpreneCTPA2LSA-PAP1-XXXXX 3.5 80 NorpreneCTPA3HSA-PAP1-XXXXX 8 110 NorpreneCTPA3LSA-PAP1-XXXXX 8 70 NorpreneCTPA4HSA-PAP1-XXXXX 13 100 NorpreneCTPA4LSA-PAP1-XXXXX 13 50 NorpreneCTPA6LSA-PAP1-XXXXX 30 40 NorpreneCTPA6HSA-PAP1-XXXXX 30 80 Norprene
Series CTP-A Duplex (Peristaltic Pumps)CTPB2LSA-PAP1-XXXXX 7 80 NorpreneCTPB3LSA-PAP1-XXXXX 16 70 NorpreneCTPB4LSA-PAP1-XXXXX 26 50 NorpreneCTPB6LSA-PAP1-XXXXX 60 40 Norprene
Series CTP-AE Simplex (Peristaltic Pumps)CTPA2HEA-PAP1-XXXXX 3.5 125 NorpreneCTPA2LEA-PAP1-XXXXX 3.5 80 NorpreneCTPA3HEA-PAP1-XXXXX 8 110 NorpreneCTPA3LEA-PAP1-XXXXX 8 70 NorpreneCTPA4HEA-PAP1-XXXXX 13 100 NorpreneCTPA4LEA-PAP1-XXXXX 13 50 NorpreneCTPA6LEA-PAP1-XXXXX 30 40 NorpreneCTPA6HEA-PAP1-XXXXX 30 80 Norprene
Series CTP-AE Duplex (Peristaltic Pumps)CTPB2LEA-PAP1-XXXXX 7 80 NorpreneCTPB3LEA-PAP1-XXXXX 16 70 NorpreneCTPB4LEA-PAP1-XXXXX 26 50 NorpreneCTPB6LEA-PAP1-XXXXX 60 40 Norprene
Series CTP-D Simplex (Peristaltic Pumps)CTPD2HSA-PAP1-XXXXX 7 125 NorpreneCTPD3HSA-PAP1-XXXXX 16 110 NorpreneCTPD4HSA-PAP1-XXXXX 26 100 NorpreneCTPD6HSA-PAP1-XXXXX 60 80 Norprene
Series CTP-D Duplex (Peristaltic Pumps)CTPE2HSA-PAP1-XXXXX 14 125 NorpreneCTPE3HSA-PAP1-XXXXX 32 110 NorpreneCTPE4HSA-PAP1-XXXXX 52 100 NorpreneCTPE6HSA-PAP1-XXXXX 120 80 Norprene
Chem-Tech Prime Performance™ PumpsThe new Chem-Tech Prime Performance™ pump combinesPulsafeeder’s proven degassing technology with thedurability and dependability that has earned Chem-Tech®
pumps the respect of water treatment professionals aroundthe world. The result is a series of positive displacementdiaphragm metering pumps that are totally self priming andmaintain their prime even in the most demanding waterconditioning and water treatment applications. Pump sizesare 15, 24, or 30 GPD @ 100 PSI and driven by 115VACmotors.
Series CTP (Peristaltic Pumps)The Series CTP offers a bold new look in reliability andvalue and is available in three control options offering feedrates up to 60 GPD (9.5L PH) with pressures to 125 PSI ( 8.6bar).
The Series CTP-A includes a percentage dial for reliableoperation and adjustable feed rates in 5-second increments.
The Series CTP AE is a 100% fixed rate economy modelwith an off-on dial for applications requiring constant feedand easy use.
Both Series CTP-A and Series CTP-AE models are availablewith optional 7-day timers for biocide feed or other timedapplications.
For applications requiring precise feed rates, the SeriesCTP-D offers digital control from 10% to 100% up to 60 GPD(9.5LPH). Adjustable in 1% increments, the Series CTP-Dprovides maximum control for demanding applications.
Simplex and duplex head configurations are both available.
*Standard Duplex models are of like pressure and flow rate
Peristaltic Tubing Option. - FLURAN® Severe Environment TubingThe tubing option is the sixth position in the model number, which is coded as “H” or “L” in thestandard CTP models. Standard tubing on all models is norprene. The FLURAN tubing optionis not available on CTP-A/AE duplex models or on models with a max flow rate greater than24 GPD. Max pressure rating with FLURAN tubing is 60 PSl. When ordering FLURAN tubing,replace the “L” or “H” in the model number with “F”.Pos. 5&6 CTP-A/AE Models CTP-D Models2F 3 GPD 7 GPD3F 8 GPD 16 GPD4F 13 GPD 26 GPD
Control OptionsThe control option is the seventh position in the model number, which is coded asan “S” in the standard Series CTP-A / CTP-D and as “E” in the standard SeriesCTP-AE. When ordering one of the following options, replace the “S” or “E” with theappropriate control option code listed below.Position 7 DescriptionT 7 Day Mechanical Timer (2 hr. increments) with Series CTP-AR 7 Day Mechanical Timer (2 hr. increments) with Series CTP-AED 7 Day – 8 Event Electronic Timer (1 min. increments) with
Series CTP-A / CTP-DC 7 Day – 8 Event Electronic Timer (1 min. increments) with
Series CTP-AE
68 CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS
LMI® Series Chemical Metering Pumps
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
Series A, B and C LMI® Chemical Metering Pumps have been an industry
standard for over 20 years. The familiar yellow and black pumps have a rugged,
totally enclosed, chemically resistant housing for protection in the harshest
environments. Encapsulated electronics and a rigid housing and stroke bracket
ensure years of precise, repeatable performance.
The Series P Metering Pump is designed for more economical chemical injection.
The totally enclosed, chemically resistant housing and encapsulated electronics
provide the performance and long life. Dual manual control of stroke speed and
length and fixed speed versions are available for simple manual or on/off control.
Ordering Information
Catalog # GPH PSI Head & Fittings Repair Kit Part Catalog #A Series
AA141-155S .58 250 PP SP-U9AA151-95S 1 110 PP SP-U1AA151-392SI 1 110 PVDF/PVDF RPM-392AA161-362SI 2 50 PVDF/PVDF RPM-362AA171-352SI .42 140 PVDF/PVDF RPM-352AA741-352SI .42 140 PVDF/PVDF RPM-352AA751-392SI 1 110 PVDF/PVDF RPM-392AA771-352SI .42 140 PVDF/PVDF RPM-352AA941-352SI .58 250 PVDF/PVDF RPM-352AA951-392SI 1 110 PVDF/PVDF RPM-392AA971-352SI .42 140 PVDF/PVDF RPM-352
B SeriesB111-392SI 1.6 150 PVDF/PVDF RPM-392B121-393SI 2.5 100 PVDF/PVDF RPM-393B721-490SI 2.5 100 Acrylic/PVC RPM-490B911-398SI 1.6 150 PVC/PVC RPM-398B921-393BI 2.5 100 PVDF/PVDF RPM-393
C SeriesC101-94S 1.3 300 PVC/PVC SP-U1C111-75S 2.5 150 PP SP-U2C121-362BI 4 100 PVDF/PVDF RPM-362C131-313BI 8 60 PVDF/PVDF RPM-313C141-35T 20 25 PP SP-U6C701-94S 1.3 300 PVC/PVC SP-U1C731-20S 8 60 Acrylic/PVC SP-20C771-20S 10 80 Acrylic/PVC SP-20C911-363BI 2.5 150 PVDF/PVDF RPM-363C921-363BI 4 100 PVDF/PVDF RPM-363C931-313SI 8 60 PVDF/PVDF RPM-313
P SeriesP021-352BI .21 150 PVDF/PVDF RPM-352P121-352SI .21 150 PVDF/PVDF RPM-352P131-392SI .42 110 PVDF/PVDF RPM-392P141-352SI .58 250 PVDF/PVDF RPM-352P151-392BI 1 110 PVDF/PVDF RPM-392P161-362BI 2 50 PVDF/PVDF RPM-362P741-352BI .58 250 PVDF/PVDF RPM-352P751-392BI 1 110 PVDF/PVDF RPM-392P761-362BI 2 50 PVDF/PVDF RPM-362
Control Options:Type “9” control is designed for easyintegration into chemical feed systems.The stroke rate may be controlledmanually or by an external signalgenerated by a flowmeter, controller,transmitter, PLC or other device. Divideor multiply a digital (pulse) input orprogram a response to a milliamp (4-20,0-20, 20-4, 20-0) input. The optional Digi-Pulse Flow Monitor verifies chemical flowand provides an alarm output.
Type “7” control is designed for moreeconomical systems. The stroke rate maybe controlled manually or by a digitalinput. The optional Micropace ControlModules enable the user to divide ormultiply a digital input or respond directlyand proportionally to a 4 - 20 milliampinput.
Type “1” control is designed for accuratechemical feed where manual or on/offcontrol is all that is required. Dual manualcontrol of stroke speed and stroke lengthis provided.
NOTE: S and SI suffix indicate 4-Function ValveBI suffix indicate Bleed Valve
*Please contact Technical Support for additional pump selections LMI Part # System example: AA151-392SIAA= Pump Series1= Control Code5= Output Code1= Voltage Code3= LiquiPro Series9= Head Size2= MaterialS= Valve CodeI= Tubing Code
69CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS
PULSAtron® Chemical Metering Pumps
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Siemens offers a vide variety of PULSAtron® metering pumps. After more than 10
years of product evolution, the PULSAtron® standard continues to set the pace
with the recent introduction of the DG/5FV degas valve. PULSAtron® pumps can
successfully handle a variety of gaseous solutions previously relegated to other
metering technologies. The Pulsatron® family consists of six unique Series with
76 flow and pressure ranges to choose. Most models include our standard Bleed
Valve assembly, foot strainer, injection valve and tubing. No matter what your
application, choose the PULSAtron® metering pump that is right for you.
ORDERING INFORMATION
Catalog # GPH PSI Head & Fittings KOP Kit Catalog #
Series MP LMK2TA-KTC1-500 3 300 PVDF K2KTC1LMB2TA-KTC1-500 5 250 PVDF K2KTC1LMD3TA-KTC1-500 11 250 PVDF K3KTC1LMF4TA-KTC1-500 20 250 PVDF K4KTC1LMH4TA-KTC1-500 40 250 PVDF K4KTC1
Series E PlusLPA2SA-KTC1 6 150 PVDF K2KTC1LPB3SA-KTC1 12 150 PVDF K3KTC1LPD4SA-KTC1 21 150 PVDF K4KTC1LPG4SA-KTC1 42 150 PVDF K4KTC1LPH5SA-KTC3 75 150 PVDF K5KTC3LPH6SA-KTC3 120 100 PVDF K6KTC3LPH7SA-KTC3 240 35 PVDF K7KTC3LPH8SA-WTCB 500 20 PVDF K8WTCB
Series ELPB2SA-KTC1 5 250 PVDF K2KTC1LPD3SA-KTC1 11 250 PVDF K3KTC1LPF4SA-KTC1 20 250 PVDF K4KTC1LPH4SA-KTC1 40 250 PVDF K4KTC1
Series A PlusLB02SA-VTC1 6 150 PVC K2VTC1LB03SA-VTC1 12 150 PVC K3VTC1LB04SA-VTC1 22 100 PVC K4VTC1LB64SA-VTC1 30 100 PVC K4VTC1
Series C PlusLD02SA-VTC1 6 80 PVC K2VTC1LD03SA-VTC1 12 80 PVC K3VTC1LD04SA-VTC1 22 80 PVC K4VTC1LD54SA-VTC1 30 80 PVC K4VTC1
Series CLC02SA-VTC1 6 80 PVC K2VTC1LC03SA-VTC1 12 80 PVC K3VTC1LC04SA-VTC1 22 80 PVC K4VTC1LC54SA-VTC1 30 80 PVC K4VTC1
Series MPThe Series MP is a true microprocessor controlled instrument forprecise and accurate metering control. Series MP includeautomatic control via 4-20mA or 20-4mA inputs, external pace withstop feature and 16-character LCD display.
Series E PlusThe Series E Plus offers manual control over stroke length andstroke rate as standard with the option to choose between 4-20mAor external pace inputs for automatic control.
Series EThe Series E offers manual function controls over stroke lengthand stroke rate providing a turn down ratio 100:1.
Series A PlusThe Series A Plus offers manual control over stroke length andstroke rate as standard with the option to select external pace forautomatic control.
Series C PlusLike the Series A Plus, the Series C Plus offers manual controlover stroke length and stroke rate as standard with the option toselect external pace for automatic control.
Series CThe Series C offers manual on-line stroke length adjustment withfixed stroke rate. Optional control features include external pace achoice between momentary on/off switch for priming the pump ora toggle on/off switch for manual override of all control functions.
NOTE: The -500 indicate 5-Function Bleed Valve
*Please contact Technical Support for additional pump selections
70
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS
PULSAtron® Plus Chemical Metering Pumps
Water treatment professionals are under constant pressure to understand newchemical treatment programs. While some applications require sophisticatedcontrol systems with multi-parameter inputs and outputs, many installations canbe satisfied with a simpler approach. The PULSAtron® Plus is the ideal choicewhen basic control is all that is required.
PULSAtron® Plus is a unique family of products that combine basic controlfunctions into a PULSAtron® pump, eliminating the need for separate pieces ofequipment. Available across a full range of pump capacities and pressure ratings,each member of the PULSAtron® Plus family incorporates a variety of controlfeatures that target specific applications.
ORDERING INFORMATION
Catalog # GPH PSI Head & Fittings DescriptionSeries CW
LWO2RAVHC12XXXX .25 150 PVC/Hypalon Rising Set Point,LWO3RAVHC12XXXX .5 150 PVC/Hypalon ll5V, .25” IDLWO4RAVHC12XXXX 1 100 PVC/Hypalon Tubing, SSLW64RAVHCI2XXXX 1.25 100 PVC/Hypalon Sensor w/ 8.5’
Cable, No FlowSwitch
Series CLLLO2RAVHCT2XXXX .25 150 PVC/Hypalon Rising Set Point,LLO3RAVHCI2XXXX .5 150 PVC/Hypalon ll5V, .25” IDLLO4RAVHC12XXXX 1 100 PVC/Hypalon Tubing, SSLL64RAVHC12XXXX 1.25 100 PVC/Hypalon Sensor w/ 8.5’
Cable, No FlowSwitch
Series WTLQ02XAVHClXXXXX .25 150 PVC/Hypalon 115V, .25"LQ03XAVHCTXXXXX .5 150 PVC/Hypalon Tubing, No FlowLQ04XAVHCIXXXXX 1 100 PVC/Hypalon SwitchLQ64XAVHClXXXXX 1.25 100 PVC/Hypalon
Series T7LCl3BAVHClXXX .5 100 PVC/Hypalon 115V, .25"LCl4BAVHCTXXX 1 100 PVC/Hypalon TubingLC64BAVHC1XXX 1.25 100 PVC/HypalonLC44BAVHClXXX 2 50 PVC/Hypalon
Series ETLTB2SAVHCTXXX .21 250 PVC/Hypalon Manual On/Off,LTF4SAVHCIXXX .85 250 PVC/Hypalon 115V, .25"LTH4SAVHCIXXX 1.70 250 PVC/Hypalon TubingLTA2SAVHC1XXX .25 150 PVC/HypalonLTB3SAVHClXXX .50 150 PVC/HypalonLTD4SAVHClXXX .90 150 PVC/HypalonLTG4SAVHClXXX 1.75 150 PVC/HypalonLTHSSAVHC1XXX 3.15 150 PVC/HypalonLTA3SAVHC1XXX .50 100 PVC/HypalonLTB4SAVHC1XXX 1 100 PVC/HypalonLTE4SAVHC1XXX 1.85 100 PVC/HypalonLTH6SAVHC1XXX 5 100 PVC/HypalonLTH7SAVHCIXXX 10 35 PVC/HypalonLTH8SAVHClXXX 21 20 PVC/Hypalon
Series CW: Conductivity Control with Water Meter FeedThe Series CW provides conductivity control with a water meterfeed. Bleed is initiated when the conductivity level reaches theuser specified set point. Chemical feed is initiated and controlledby input from a water meter. The Series CW includes a solenoidactuated metering pump, conductivity sensor, bleed relay and adry contact input for water meter control.
Series CL: Conductivity Control with Limit TimerThe Series CL provides conductivity monitoring and control with aLimit Timer that controls the feed time. Tower feed and bleed areinitiated when the conductivity levels reaches the user-specifiedset point. The programmable limit timer allows the operator tospecify the maximum pumping time for the feed cycle. The SeriesCL includes a conductivity sensor, bleed relay and a user-programmable limit timer.
Series WT: Feed & Bleed Control with Water Meter InputThe Series WT provides feed and bleed control with a watermeter input. The feed and bleed cycles are initiated and controlledby input form the water meter. Separate programmable pulsetimers control the pump and bleed relay. The Series WT includesa flow input, water meter input and two programmable pulsetimers.
Series T7: Feed Control with 7 Day TimerThe Series T7 was designed to control the feeding of biocide orother product that must be fed on a timed schedule. The SeriesT7 includes a 7-day programmable timer and clock with the abilityto control up to 8 on/off cycles per day. Each timed event can beset to run any day of the week on a 7-day cycle. The feed cycle isinitiated and controlled by the user programmable timer.
Series ET: Feed Control with Water Meter InputThe Series ET provides feed control with input from a water meterinput. When the count exceeds a set value (either 1 or 10), thepump starts. The pump will continue to run for an adjustable timeperiod. The Series ET includes both input and output water meterconnections at the front panel. The output connection provides anisolated dry contact output of the water meter contact to operateadditional pumps or timers off the same water meter.
71
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS
Wallace & Tiernan® Metering PumpsCHEM-AD® XL Diaphragm Metering Pump
The CHEM-AD® XL range of metering pumps are mechanically actuateddiaphragm dumps with integrated controls capabilities. Capacities up to 238 GPH
Key Controls & Features• On-off Button • Mechanical Stroke Length Control • Stroke Frequency Control, Level Switch Input (low level and empty) • Power Cord and Plug up to 3.5 GPH • External Analog Scalable Input (0/4-20 mA), (20-0/4mA)• Input Signal Scaling, External Pulse Input• Remote On / Off • Batch Mode & Pulse Storage • Alarm Output & Stroke Pulse Output • Membrane Touch Pad Operator Interface • Flow Monitoring (External OGM required)• Integral Back-lit Digital Display• Password Protection, Capacity display, Flow Totalizing
Ordering Information
CHEM-AD® XL Diaphragm Metering Pumps with Integrated ControlsCatalog # GPH PSI DescriptionCM1A4E60KFC9931 0.44 120 Automatic E60 Speed Controls with degas system, PVDF Liquid Ends, Ceramic Ball, Viton® O-ringsCM1B4E60KFC9933 1.36 120 Automatic E60 Speed Controls, PVDF Liquid Ends, Ceramic Ball, Viton O-ringsCM1B6E60KFC9933 3.5 60CM1C1E60PFC9936 5 120 Automatic E60 Speed Controls, PP Liquid Ends, Ceramic Ball, Viton O-ringsCM1C3E60PFC9936 17 120CM1C5E60PFC9939 38 35CM1D1E60PFC9939 44 120
AccessoriesSuction Lance: Includes Dual Level Switches, Foot Valve, and Strainer
AAB5197 Suction Lance, used in Series A & B all sizesAAB5206 29.5" long, PVC Pipe, Viton® O-rings, Glass Ball
44.3" long, PVC Pipe, Viton O-rings, Glass BallAAC2411 Thrust Piece – one (1), required per suction lance with Series A
Use DUO hose to connect to suction valve.AAC2423 Adapter – one (1), required per suction lance with Series B
Use 3/8" OD x 1/4" ID tubing to connect to suction valveAAB7732 Suction Lance, used in Series C1, C2 & C3 (5 to 17 GPH)
55.1" long, PVC Pipe, Viton O-rings, Glass BallAAC8111 Connection Set – two (2), required per suction lance with Series C
Use 1/4" OD x 3/8" ID tubing to connect to the suction valve
Multifunction Valve (Functions include – Back Pressure, Pressure Relief, Draining & Priming.)AAB5248 Multifunction Valve, used in Series B all sizes (0.44 to 3.5 GPH)
Back Pressure Range, 15 – 75 PSI, PVDF Housing, Viton® O-rings.AAC5663 Thrust Piece – two (2) required per valve with Series BAAB6973 Multifunction Valve, used in Series C1, C2 & C3 (5 to 17 GPH)
Back Pressure Range, 15 – 75 PSI, PVDF Housing, Viton O-rings. AAC2513 Adapter, two (2) required per valve on Series C1, C2 & C3
Rigid piping installation AAC8111 Connection Set – two (2) required per valve on Series C1, C2 & C3
Flexible tubing connection. AAB7003 Multifunction Valve, used in Series C4 & C5 (25 to 38 GPH)
Back Pressure Range, 15 – 75 PSI, PVDF Housing, Viton O-rings. AAC8132 Adapter, two (2) required per valve on Series C4 & C5, Rigid piping installation
Wall Mount BracketAAC7594 Wall Mounting Bracket (ABS) for Series A, B & C
72
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS
Wallace & Tiernan® Metering PumpsENCORE® 700 Diaphragm Metering Pumps
Ordering Information
The Encore® 700 Diaphragm Metering Pump combines the robustness ofhydraulic pump with CONTROL FLEXIBILITY diaphragm pumps with theunparalleled economy, simplicity, and serviceability of a mechanical pump. TheEncore® 700 pump is engineered to handle industrial and municipal meteringapplications in water and wastewater treatment, swimming pools, foodprocessing, chemical processing, brewing and distillation, and agriculture.
• Non-loss-motion variable eccentric stroke adjust mechanism rendersefficiency, longevity, and reliability, as well as a smooth discharge pattern.
• Precision-engineered liquid ends meter mild solutions, aggressivechemicals, high-viscosity polymers, and slurries with greater efficiency thanconventional liquid ends.
• Clear PVC cartridge valves for fast service with no piping disturbances andbuilt-in visual indication of operation.
• Premium composite diaphragm design ensures high metering accuracy,even at varying discharge pressures.
Encore® 700 Diaphragm Metering Pump
Catalog # GPM PSI PVC Head / PTFE Diaphragm / Hypalon O-ring / Manual Control
AAC1751 5 175 1/4 HP, 110VAC 1PH MOTOR
AAC1757 24 175 1/4 HP, 110VAC 1PH MOTOR
AAC1763 45 150
3/4 HP, 110VAC 1PH MOTORAAC1769 77 130
AAC1775 180 75
For higher capacities and options consult factory.
Additional metering pumps and water treatment accessories from leading manufactures are available.Contact Siemens Water Technologies for a complete list of options.
73CHEMICAL FEED SYSTEMS AND ACCESSORIES - METERING PUMPS
Wallace & Tiernan® Metering PumpsChemtube® PPS Peristaltic Pumps
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
In the industrial marketplace, the Chemtube® PPS hose pumps are suitable formetering virtually any chemical to the point of application. Reliable feed ratesare maintained in either continuous or intermittent duty cycles.
There are many industrial applications for the Chemtube® PPS Hose pumps thatgo beyond our traditional metering pump capabilities. Chemtube® PPS pumpsare ideal for,
• Multiphase fluids• Shear Sensitive products & high viscosity products• Slurries & abrasive products with high solid contents • Highly corrosive products• High Suction Lift conditions• Self-priming design which will not air-lock
Ordering Information
Chemtube® PPS :S Series
Pump Catalog # GPH PSI RPM Hose and Connection Material Repair Kit Part No.
CPS5B3GRP 2.2
9025
Natural Rubber and PVC Connections
Hose: AAC7676Repair Kit: AAC7931
CPS10B3GRP 7.0Hose: AAB7676Repair Kit: AAC7931
CPS16B3GRP 25Hose: AAB7691Repair Kit: AAC7934
CPS26B3GRP 115 22Hose: AAB7706Repair Kit: AAC7937
CPS5B3GHP 2.2
9025
Hypalon Hose and PVCConnections
Hose: AAC1799Repair Kit: AAC7931
CPS10B3GHP 7.0Hose: AAC1799Repair Kit: AAC7931
CPS16B3GHP 25Hose: AAC1802Repair Kit: AAC7934
CPS26B3GHP 116 22Hose: AAC1805Repair Kit: AAC7937
Pulsation Dampener (max 150 PSI )
Pump Model No. Catalog # Body and Diaphragm Material Connection Size
S Series – S5 AAB7874
PVC / Hypalon
1/2” NPT (F)S Series – S10 AAB8657
S Series – S16 AAB8858 3/4” NPT (F)
S Series – S26 AAB8876 1” NPT (F)
Pressure Relief Valve (10 – 150 PSI)
S Series S5, S10, S16, S26 AAB8816 PVC / PTFE / EPDM 1/2” NPT (F)
Note: 1: All Chemtube® PPS models include ,S Series Pump with 5/10/16/26 mm hose, Variable Frequency Drive with
NEMA 4X enclosure, 230 VAC/60Hz/3Ph, Inverter Duty Motor 230 VAC/60Hz, PVC connections, Natural RubberHose or Hypalon Hose, Leak Detector, One spare hose, Two year warranty excluding hose.
2: Refer to chemical compatibility chart for Hose material selection. Consult factory for special requirements.3: For higher capacities and options consult factory.
Accessory required for Chemtube® PPS Hose Pumps
74
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS
Instrumentation & Controls
Siemens offers a wide selection of instrumentation and control for cooling waterand process water applications. Whether you need to control pH, ORP,conductivity, or more, Siemens has a controller or monitor to fit the application.
Ultrameter™ Series Instruments
While priced like affordable single-parameter instruments,the Ultrameter™ does the job of three, four or even sixinstruments. All Ultrameter™ models deliver performanceof ±1% of reading (not merely full scale). This high level ofaccuracy has been achieved through advanced four-electrode conductivity cell technology, a unique pH/ORPsensor and powerful microprocessor-based circuitry. Withdisplayed values of up to 9999, the full four-digit LCDensures resolution levels never before possible in suchaffordable instruments.
Ultrameter™ InstrumentsCatalog # Mode # DescriptionMETMYRNL4P 4PII Conductivity, TDS, Resistivity & TemperatureMETMYRNL6P 6PII Conductivity, TDS, pH, Resistivity, Temperature & ORP
TMS-561 Turbidimeter
The TMS 561 Turbidimeter is specifically designed for continuouson-line measurement of turbidity in filtered or raw water inmunicipal and industrial water treatment plants, as well as finaleffluent in wastewater applications. Utilizing an EPA-approved,reusable, primary standard, routine calibration is fast andinexpensive. For poor-quality water, an ultrasonic, self-cleaningsystem is available to reduce maintenance. An optional dataacquisition system and software package allows networking ofup to 255 turbidimeters into a single computer. The softwareprovides graphical trending, alarms, and filter analysis.
Depolox® 3 plus
The Depolox® 3 plus residual analyzer continuouslymeasures free or total (combined) chlorine in drinkingwater applications. Utilizing proven and universallyaccepted amperometric measurement technology, theDepolox® 3 plus analyzer directly measures chlorineresiduals and provides a 4- 20 mA output signal forcontrol or recording purposes. Integral alarm relays areincluded. The Depolox® 3 plus analyzer is also availablein a dual input arrangement for measuring pH orfluoride, along with chlorine.
*Please contact Technical Support for Depolox®
analyzer options
TMS-561 TurbidimeterCatalog # Light Range Ultrasonic
CleaningTMS-561 BW White 0-1000 NTU N/ATMS-561 BR Infrared 0-1000 NTU N/ATMS-561 CW White 0-100 NTU StandardTMS-561 CR Infrared 0-100 NTU StandardTMS-561 DW White 0-1000 NTU StandardTMS-561 DR Infrared 0-1000 NTU Standard
Contact Technical Support for additionalinformation on our entire chemical feedand control offerings including:
• Gas Feed Systems• Dry Feed Systems• On-Site Electrochlorination• Liquid Metering Systems• UV Systems• Custom Chemical Feed Systems• Analytical Instrumentation• Chemical Induction Systems• Flow Measurement & Control
75CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS
Instrumentation & Controls(continued)
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Siemens offers a wide selection of instrumentation and control for cooling waterand process water applications. Whether you need to control pH, ORP,conductivity, or more, Siemens has a controller or monitor to fit the application.
Strantrol® Feed Verification Controller (FVC Series)
The Strantrol® FVC provides accurate and reliable dosingmeasurement for a wide selection of metering pumps.The Strantrol® FVC controls and verifies the liquidchemical feed rate of actual chemical dispensed. Aproportional feedback signal changes the stroke rate ofthe pump compensating for changes in pump output.
Strantrol® 916 Controller Series
Strantrol® 916P ControllerThe Strantrol® 916P Controller accurately and reliablymaintains pH and conductivity control in industrialprocess water and cooling water applications. The 916PController combines innovative sensor technology withunique control schemes to offer an unequaled solutionfor industrial water treatment applications.
Strantrol® 916O ControllerThe Strantrol® 916O Controller is configured for HighResolution Redox® sensing and conductivity control,which can dramatically improve disinfection ofindustrial process water and cooling water applications.
Strantrol® 885, 886 and 887 Controllers
The Strantrol® 885, 886 and 887 series of controllersoffer the reliability and precision that only comes with aStrantrol® product. These single channel controllers areavailable for ORP, pH or conductivity monitoring andcontrol.
LMI® Controllers
LMI® controllers are simple to setup and operate. Allwiring and connections are included. Choose form pH,conductivity or ORP controllers for a variety ofapplications.
Strantrol® Feed Verification ControllersCatalog # Min GPH Max GPHFVC-1.6 .079 1.58FVC-16 1.58 15.85FVC-32 3.17 31.7FVC-63 6.34 63.4FVC-158 15.85 158.5FVC-317 31.7 317.0
Strantrol® 916 ControllersCatalog # Description916P Conductivity / pH Controller System916O Conductivity / ORP Controller System
LMI® ControllersCatalog # DescriptionDC-5500 Conductivity Controller for Cooling with
Biocide Timers & Remote CommunicationsDC-4000 Conductivity Controller for Cooling or Boiler
(Bleed & Feed)DC-4500 Conductivity Controller for Cooling with
Biocide TimersDP-5000 pH Controller DR-5000 ORP Controller
Strantrol® 88X ControllersCatalog # DescriptionStrantrol 885 Conductivity / Temperature Controller Strantrol 886 pH Controller Strantrol 887 High Resolution Redox® (ORP) Controller
76 CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS
PULSAtrol® Series
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
The PULSAtrol® series economical and reliable controllers are easy to use andrequire minimum maintenance.
Ordering Information
MC9000 Series ControllersCatalog # DescriptionMTC1PTXXXX Prewire, 115VAC, with sensor tee
MC9200 Series ControllersMC9210XXXXXX Conductivity ControlMC9220XXXXXX pH ControlMC9230XXXXXX Conductivity and pH Control
MC9300 Series ControllersMC9310XXXXXX Conductivity ControlMC9320XXXXXX pH ControlMC9330XXXXXX Conductivity and pH Control
MC9500 Series ControllersMC9510XXXXXX Conductivity ControlMC9520XXXXXX Conductivity and ORP ControlMC9530XXXXXX Conductivity and pH ControlMC9540XXXXXX Conductivity, make-up conductivity and pH ControlMC9550XXXXXX Conductivity (with make-up), pH and ORP COntrolMC9560XXXXXX Dual Conductivity for open loop (tower)
and closed loop (chiller)MC9570XXXXXX Dual Conductivity for dual cooling tower systems
PULSAtrol® MC9000 Series ControllersThe PULSAtrol® 9000 Series cooling tower controllers offer the most popular features asstandard without compromising flexibility. All controllers come standard with a complete flowassembly mounted to a polypropylene backboard.
MC9200 SeriesThe MC9200 Series includes as standard, a pre-wired selectable timer, alarm output relay, drycontact alarm output and water meter totalizer. Options available include up to two 28-day biocidetimers, single or dual 4-20mA outputs, communications and agency approvals (Contact factory foroptions).
MC9300 SeriesThe MC9300 Series includes as standard, four taggable timers, two water meter totalizers userconfigured as dry contact or hall effect, dry contact alarm relay and alarm output relay. Options include two 4-20mA outputs, conduit connection for power and relays, communications, language and agencyapprovals (Contact factory for options).
MC9500 SeriesThe MC9500 Series includes as standard, four taggable timers, two water meter totalizers userconfigured as dry contact or hall effect, four drum level inputs, dry contact alarm relay and alarmoutput relay. Options include two 4-20mA outputs, conduit connection for power and relays,communications, language and agency approvals (Contact factory for options).
77CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS
Boilers PULSAtrol® Series
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Ordering Information
MB9200 Series Boiler ControllersCatalog # DescriptionMB9210XXXXX Conductivity ControlMB9220XXXXX Dual Conductivity Control
MB9300 Series Boiler ControllersMB9210XXXXX Conductivity ControlMB9220XXXXX Dual Conductivity Control
MB9600 Series Boiler ControllersMB9610XXXXXX Conductivity ControlMB9620XXXXXX Dual Conductivity ControlMB9630XXXXXX Triple Conductivity ControlMB9640XXXXXX Conductivity Condensate / pH Control
Siemens now offers the PULSAtrol® Series of boiler control instrumentation.These economical and reliable controllers are easy to use and require minimummaintenance.
MB9200 SeriesThe MB9200 Series includes as standard, two selectable timers, alarmoutput relay, dry contact alarm output, water meter totalizer, stainlesssteel sensor and mounting hardware for each boiler. Options includesingle or dual 4-20mA outputs, communications and agency approvals(Contact factory for options).
MB9300 SeriesThe MB9300 Series includes as standard, four selectable timers, alarmoutput relay, dry contact alarm output, two water meter totalizers andtemperature compensated stainless steel sensors. Options include singleor dual 4-20mA outputs, communications, language and agencyapprovals (Contact factory for options).
MB9600 SeriesThe MB9600 Series includes as standard, three or four selectable timers,two water meter totalizers user configured as dry contact or hall effect,four single point drum level inputs, dry contact alarm relay, alarm outputrelay and temperature compensated stainless steel sensors. Optionsinclude up to four 4-20mA inputs and outputs, communications, languageand agency approvals (Contact factory for options).
78
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
Siemens now offers the Vision Series of process control instrumentation. TheVision Series product line is designed to handle a multitude of applications and ismodular and expandable. The innovative use of USB technology makes theseunits customizable. Soft keys allow for easy programming and flexibility.
Model UVThe Vision Series Model UV is a single system process controlinstrument. Included as standard are two IntelliSense® sensorconnections allowing for the use of one Multipurpose IntelliSense®sensor input/output and one general sensor IntelliSense® sensorinput (conductivity, torodial, pH or ORP); four selectable relays, onealarm relay, three taggable timers, one flow switch input, and oneinput suitable for use with dry contact or hall effect water meters.
Model LVThe Vision Series Model LV is a dual system process controlinstrument. As standard, it comes with three IntelliSense® sensorconnections (allowing for the use of three general sensor inputs, twogeneral sensor inputs and one multipurpose input/output, or onegeneral sensor input and two multipurpose inputs/outputs), fourselectable relays, one alarm relay, six taggable timers, two flowswitch inputs, and two inputs suitable for use with dry contact or halleffect water meters.
IntelliSense® Sensor PackageBy converting an analog input to a digital signal, the IntelliSense®sensor provides auto sensor recognition, eliminates drifting potentialand allows travel up to 1000 feet (when using a RS-422 connection).USB connections are limited to 15 feet. Each of the 5 availablesensory heads are color coded and measure a multitude of variables.NOTE: The multipurpose IntelliSense® sensor can only be used witha USB connection and consists of four functions (a contact input andoutput, and a 4-20mA input and output0, which can all be usedsimultaneously or independently.
Flow AssemblyThe flow assembly features 3/4" PVC plumbing with a flow switch andsample valve. When ordering the flow assembly you can specify ifyou would like it mounted on a panel with the process controlinstrument.
IntelliScan® Handheld Calibration UnitThe IntelliScan® Unit is a handheld device that revolutionizes thecalibration process by eliminating the need for manual data entry. Ithas an infrared port that allows calibration data to be transmitted tothe IntelliSense® sense form the IntelliScan® unit. The IntelliScan®unit comes with its own convenient carrying case and belt-clipattachment.
Vision UV Single System Process ControllerCatalog # DescriptionUVPSI XXX Prewire, 115VAC, No Communications, No PanelUVP2SXXX Prewire, 115VAC, Modem Connection, No PanelUVP3SXXX Prewire, 115VAC, Ethernet Connection, No Panel
Vision LV Dual System Process ControllerLVPI SXXX Prewire, 115VAC, No Communications, No PanelLVP2SXXX Prewire, 115VAC, Modem Connection, No PanelLVP3SXXX Prewire, 115VAC, Ethernet Connection, No Panel
Vision IntelliSense® Sensor PackageISPCSTDU015XXX Std. Conductivity Probe, USB Connection with 15' CableISPTSTDU015XXX Std. Toroidal Probe, USB Connection with 15' CableISPPSTDU015XXX Std. pH Probe, USB Connection with 15' CableISPOSTDU015XXX Std. ORP Probe, USB Connection with 15' CableISPMXXXU015XXX No Probe (for MPIO only), USB Connection with 15' CableISPCCBSU015XXX Boiler Conductivity Probe, USB Connection with 15' Cable
Vision Flow AssemblyFAOTXL No Sensor Tee, No Panel, Left Flow (Right Flow = XR)FA1TXL One Sensor Tee, No Panel, Left FlowFA2TXL Two Sensor Tees, No Panel, Left FlowFA3TXL Three Sensor Tees, No Panel, Left Flow
Vision IntelliScan® Handheld Calibration UnitISCNCDXXX IntelliScan® Unit Type - ConductivityISCNPOXXX IntelliScan® Unit Type - ph/ORPISCNCBXXX Combo (one conductivity sensor & one pH/ORP sensor)
Custom Control Package Design Procedure1. Start by selecting a UV or LV controller.2. Select the desired IntelliSense package.3. If ordering a LV unit and more than three USB inputs/outputs are
required, select a USB Hub. Please contact the factory for applicationreview and design assistance.
4. If ordering a LV unit and more than four relays are required, select aRelay Expansion Box. Please contact the factory for application reviewand design assistance.
5. Choose a flow assembly with or without a panel mount.6. Accessorize. Make your calibration high-tech. Check out the IntelliScan®
handheld.
CHEMICAL FEED SYSTEMS AND ACCESSORIES - INSTRUMENTATION & CONTROLS
Vision Series Process Control Instrumentation
79
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CHEMICAL FEED SYSTEMS AND ACCESSORIES - STORAGE AND BULK TANKS
Reverse Osmosis & Bleach Storage Tanks
Siemens offers a wide variety of storage and bulk tanks for RO systems andbleach. Each RO tank is constructed of HDPE and bleach tanks are HDXLPE and israted at 1.90 S.G. with OR1000 lining. All tanks are NSF Certified and fittingpackages are available. Secondary containment is also offered as well as heattracing and seismic restraints.
ORDERING INFORMATION
Reverse Osmosis Water Storage Tanks – HDPECatalog # Nominal Capacity Approx. O.D. Approx Overall Lid Size
Height
1006150 6150 10' – 2" 12' – 4" 24"1005050 5050 7' – 10" 16' – 0" 24"1004150 4150 8' – 6" 12' – 6" 24"1003000 3000 7' – 1" 11' – 8" 24"1002000 2000 7' – 1" 8' – 6" 24"1001150 1150 5' – 4" 8' – 2" 10"/19"1100475 475 4' – 0" 6' – 3" 17"1000100 100 1' – 11" 5' – 7" 7"
Reverse Osmosis Water Storage Tanks – FittingsCatalog # DescriptionVenting7457 3" Mushroom Vent – PPPump Suction7117 2" BHF PVC/EPDM4844 Nipple 2" x Short PVC3188 2" T x T Spears Compact Ball Valve PVCLevel7117 2" BHF PVC/EPDMFill7117 2" BHF PVC/EPDMOptional Overflow7117 2" BHF PVC/EPDM
Bleach Storage & Bulk TanksCatalog # Nominal Capacity Approx. O.D. Approx. Overall Lid Size Secondary
Height Containment Catalog #
1000540 540 4' – 0" 6' – 9" 19" 15007001000805 805 4' – 0" 9' – 11" 19" 15009601000905 907 5' – 4" 6' – 9" 19" 15012001001300 1300 7' – 1" 5' – 10" 19" 15020001001400 1400 5' – 4" 10' – 0" 19" 15017501002000 2000 7' – 1" 8' – 6" 24" 15026501002650 2650 8' – 0" 8' – 9" 24" 15033501003900 3900 7' – 10" 12' – 9" 24" 1504500
Note: Larger tanks sizes are available. Contact Stranco® at 800-882-6466 for additional information.
80 CLARIFIERS
Permutit® Package PrecipitatorsFlow Rates from 44 to 920 gpm
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
Package Precipitators offer an efficient means for removing impurities from a liquid byprecipitation, adsorption, settling and upflow filtration. Used for the initial treatmentof water to reduce suspended impurities, turbidity, color, hardness, iron andmanganese, the Package Precipitator provides high rate clarification in minimumspace. Adaptable to variable flow rates, it offers excellent chemical efficiency andproduces low turbidity effluent. Optional Chevron shape, high rate tube settlers offerover 35% increased flow rate.
• Low turbidity precipitator effluent is virtually always superior to the effluent ofconventional clarifiers/softeners
• The action of suspended sludge in the mixing zone and upflow through the sludgeblanket utilizes chemicals more efficiently
• Large, slow moving agitator blades completely mix the water, chemicals and sludge
• The low turbidity effluent of a precipitator places little load on downstream filters,thus permitting longer filter runs and lower treatment costs
SYSTEM SPECIFICATIONSModel Number 1 2 3 4 5 6Maximum Flow Rate
Without Tube Settlers . . . . . . . . . . . . . . . . 44 gpm 88 gpm 132 gpm 175 gpm 220 gpm 250 gpmWith Tube Settlers . . . . . . . . . . . . . . . . . . 60 gpm 120 gpm 180 gpm 240 gpm 300 gpm 350 gpm
Surface Area . . . . . . . . . . . . . . . . . . . . . . . . 35 sq. ft. 70 sq. ft. 105 sq. ft. 140 sq. ft. 175 sq. ft. 200 sq. ft.Tube Settling Area . . . . . . . . . . . . . . . . . . . . 25 sq. ft. 50 sq. ft. 75 sq. ft. 100 sq. ft. 125 sq. ft. 150 sq. ft.Agitator Motor . . . . . . . . . . . . . . . . . . . . . . . 1/2 hp 1/2 hp 1/2 hp 1/2 hp 3/4 hp 3/4 hpInlet/Outlet Overflow Size . . . . . . . . . . . . . . 3” 4” 6” 6” 8” 8”Sludge, Blow-off & Flush-back Valve Size . . . . . . . . . . . . . . . . . . . . . . . . . . 1” 1-1/2” 1-1/2” 2” 2” 2”Detention (60 minutes). . . . . . . . . . . . . . . . . 2,600 gal. 5,200 gal. 7,800 gal. 10,400 gal. 13,000 gal. 15,000 gal.
System DimensionsW x L x H
inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96x60x126 96x120x126 96x180x126 96x240x126 96x300x126 108x300x126cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244x153x320 244x305x320 244x457x320 244x610x320 244x762x320 275x762x320
Shipping Weightlb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,000 9,000 12,000 15,000 18,000 19,000kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,722 4,082 5,454 6,804 8,165 8,618
Model Number 7 8 9 10 11 12Maximum Flow Rate
Without Tube Settlers . . . . . . . . . . . . . . . . 280 gpm 310 gpm 340 gpm 460 gpm 540 gpm 620 gpmWith Tube Settlers . . . . . . . . . . . . . . . . . . 400 gpm 450 gpm 500 gpm 680 gpm 800 gpm 920 gpm
Surface Area . . . . . . . . . . . . . . . . . . . . . . . . 225 sq. ft. 250 sq. ft. 275 sq. ft. 375 sq. ft. 440 sq. ft. 505 sq. ft.Tube Settling Area . . . . . . . . . . . . . . . . . . . . 175 sq. ft. 200 sq. ft. 225 sq. ft. 300 sq. ft. 350 sq. ft. 400 sq. ft.Agitator Motor . . . . . . . . . . . . . . . . . . . . . . . 3/4 hp 3/4 hp 3/4 hp 1 hp 1 hp 1-1/2 hpInlet/Outlet Overflow Size . . . . . . . . . . . . . . 8” 8” 10” 10” 12” 12”Sludge, Blow-off & Flush-back Valve Size . . . . . . . . . . . . . . . . . . . . . . . . . . 2” 2” 2” 2” 2” 3”Detention (60 minutes). . . . . . . . . . . . . . . . . 16,800 gal. 18,600 gal. 20,500 gal 27,700 gal. 32,500 gal. 37,350 gal.
System DimensionsW x L x H
inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120x300x126 132x300x126 144x300x126 144x408x126 144x480x126 144x552x126cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305x762x320 335x762x320 366x762x320 366x1036x320 366x1219x320 366x1402x320
Shipping Weightlb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20,000 21,000 22,000 30,000 35,000 38,000kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,072 9,526 9,980 13,608 15,876 17,237
ORDERING INFORMATIONFor Permutit® products and information contact 908-704-9027.
Chevron TubeSettler Supports
Treated WaterCollector
Agitator
Raw Water Inlet
Treated WaterOutlet
Overflow
DrainsSludgeBlowoff
81CLEAN-IN-PLACE SKIDS
CIP Series Cleaning SkidsFlow Rates from 30 to 225 gpm
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SYSTEM SPECIFICATIONSModel Number CIP-30 CIP-60 CIP-90 CIP-150 CIP-225
Flow Rate at 60 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 gpm 60 gpm 90 gpm 150 gpm 225 gpmTank Capacity (gallons) . . . . . . . . . . . . . . . . . . . . . . . . . 90 200 275 440 800Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5" 2" 2" 3" 3"Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mobile Mobile Fixed Fixed Fixed
System DimensionsH x W x D*
Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67x41x72 69x41x72 69x51x90 69x64x106 78x78x128cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26x16x28 27x16x28 27x20x35 27x25x42 31x31x50
Operating WeightIndustrial
lb. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1250 2600 3500 6000 9500kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567 1179 1588 2722 4309
Electrical RequirementsPump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 HP 5 HP 10 HP 10 HP 15 HPElectrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240/480V/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIP Series Cleaning Skids are designed for on-site cleaning of RO systems. They
can accommodate cleaning flow rates of 30–225 gpm and are compatible with
TFC or CA membrane elements.
• Factory assembled, tested and field-ready cleaning skids offer a convenient and
economical way to maximize your RO investment
• Rugged construction withstands cleaning chemicals
• CIP-30, CIP-60 are portable for quick and easy on-site cleaning
ORDERING INFORMATION
Catalog Number 67/CIP XX(X) – XXX Cleaning Skid Options (order as separate line item)
System Name . . . . . . . . . . . . . . 67/CIP 30 = 30 gpm Description Part Number60 = 60 gpm 240 = 240V, 60 Hz pH Monitor 24/S1900-17090 = 90 gpm 480 = 480V, 60 Hz High Temperature Switch 24/S1900-171150 = 150 gpm (Other voltages Flow Switch 24/S1900-172
Flow Rates . . . . . . . . . . . . . . . . . . . . . . 225 = 225 gpm available. Contact 1" x 25' Hose Kit 24/S1900-181Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . technical support) 1-1/2" x 25' Hose Kit 24/S1900-182
2" x 25' Hose Kit 24/S1900-1833" x 25' Hose Kit 24/S1900-184
Example: 67/CIP30-240 gpm system using 240 volts.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Continuous electrodeionization is a safe, chemical-free way to take RO (reverse
osmosis) water to a higher level of purity. CDI-LX™ systems are pre-engineered and
specifically designed to meet the demands of the pharmaceutical, power,
microelectronics and general industry customer. The standard CDI-LX™ systems
have flow rates from 2.5 to 180 gpm (0.57–40.88 m3/hr), combining single or
multiple (up to 8) CDI-LX™ modules on a frame with power supply, controllers,
piping, sample valves and cleaning connections. Flow and quality monitoring
instrumentation is standard. Remote I/O is also available as an option.
Features:
• Rugged construction • Easily validated
• Hot water sanitizable (HWS) units • Leak-free operation
available up to 185˚F (85˚C) • High operating pressure (up to 100 psi)
• High operating temperature • Low power consumption
(up to 45˚C; 113˚F)
82 CONTINUOUS DEIONIZATION (CDI®) SYSTEMS
CDI-LX™ SystemsFlow Rates from 2.5 to –180 gpm
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SYSTEM SPECIFICATIONS
Model Number CDILXH 1001 2401 3001 3002 3003 3004 3006 3008Number of Modules on Skid 1 1 1 2 3 4 6 8
Minimum Flow Rate gpm (m3/hr) 2.5 (.57) 6.25 (1.42) 7.5 (1.70) 15 (3.41) 22.5 (5.11) 30 (6.81) 45 (10.22) 60 (13.63)Nominal Flow Rate gpm (m3/hr) 5 (1.13) 12.5 (2.84) 15 (3.41) 30 (6.81) 45 (10.22) 60 (13.63) 90 (20.44) 120 (27.25)Maximum Flow Rate gpm (m3/hr) 7.5 (1.70) 18.75 (4.26) 22.5 (5.11) 45 (10.22) 67.5 (15.33) 90 (20.44) 135 (30.66) 180 (40.88)
Typical recovery 90-95% 90-95% 90-95% 90-95% 90-95% 90-95% 90-95% 90-95%
ConnectionsFeed 3/4” 1” 1” 1-1/2” 2” 2” 3" 3"Product 3/4” 1” 1” 1-1/2” 2” 2” 3" 3"Reject 1/2” 1/2” 1/2” 1/2” 1” 1” 1-1/2” 1-1/2”
Electrical Service RequiredVoltage 208/240V, 1 phase, 50/60 Hz 480V, 3 phase, 50/60 HzAmperage 15 40 40 20 30 40 60 80
System DimensionsL x D x H inches 40x33x77 40x33x77 40x33x77 40x33x77 75x40x83 75x40x83 130x40x78 130x40x78
cm 102x83x196 102x83x196 102x83x196 102x83x196 191x102x211 191x102x211 330x102x198 330x102x198Shipping Weight lb. (kg) (est.) 500 (227) 530 (240) 550 (250) 900 (408) 3000 (1361) 3300 (1497) 5000 (2268) 5600 (2540)
ORDERING INFORMATION
Catalog Number: CDILX X XX XX X X X
System Name CDILX
Number of Cell Pairs/Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . Number of Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Feed and Product Plumbing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*Not all model combinations are available. Contact Siemens for specific CDI-LX™ applications beyond the standard specifications.To determine your order number, replace the X with one of the numbered options below it. “X” must be specified if option is not requested.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
010203040608
102430
A = PVC, Sch. 80(Non HWS Model only)
D = 316L SS, Sanitary Tube (forHWS Model and X Models)
1 = 240V,1 Phase, 50/60 Hz
2 = 208V,1 Phase, 50/60 Hz
4 = 480V,3 Phase, 50/60 Hz
A = NEMA 12 withoutRemote I/O
B = NEMA 12 withRemote I/O
C = NEMA 4 withoutRemote I/O
D = NEMA 4 withRemote I/O
E = NEMA 4X withoutRemote I/O
F = NEMA 4X withRemote I/O
H = Hot Water Sanitizable (HWS)Module
X = Non-HWSModule
83CONTINUOUS ELECTRODEIONIZATIONSYSTEMS
CDI® Replacement Modules
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
CDI® Replacement modules are available for both older legacy CDI® Systems andcurrent standard CDI® Systems.
Available legacy CDI® modules: H-Series (H30, H60, H120, H240), P-Series (P-180)and Compact CDI® (C10, C20, C40) Systems. Unfortunately, the above H-Series andCompact CDI® modules cannot be replaced by LX or VNX modules due toincompatibilities with the power supply.
CDI® P-180 System Upgrade: Because of the cost savings and benefits associatedwith the CDI® LX Series, many existing P-180 customers are now upgrading to the LXSeries, and a complete upgrade kit is available. The kit is specifically designed toreplace the P-180 modules with minimal field retrofit labor required. The upgrade kitincludes simplified connections to match the existing P-180 system connections.
LX and VNX Modules: Replacement CDI® modules for current standard LX and VNXsystems.
Benefits of LX and VNX include:
• Offers the latest generation of continuous electrodeionization technology
• Offers a robust design for superior performance with the highest reliability in the industry
• Guarantees leak-free operation
• Uses the existing skid/footprint, power supplies, instruments and controls
H Series Model Numbers Replacement Module Catalog NumberH30 ZM3H030CPH60 ZM3H060CPH120 ZM3H120CPH240 ZM3H240CPP-Series Model NumbersFor All Models CDIPM0180CLX Series Model Numbers4 cell pair module – non-hot water sanitizable IP-LXM04X-310 cell pair module – non-hot water sanitizable IP-LXM10X-318 cell pair module – non-hot water sanitizable IP-LXM18X-324 cell pair module – non-hot water sanitizable IP-LXM24X-330 cell pair module – non-hot water sanitizable IP-LXM30X-34 cell pair module – instant hot water sanitizable IP-LXM4HI-310 cell pair module – instant hot water sanitizable IP-LXM10HI-318 cell pair module – instant hot water sanitizable IP-LXM18HI-324 cell pair module – instant hot water sanitizable IP-LXM24HI-330 cell pair module – instant hot water sanitizable IP-LXM30HI-324 cell pair module – E-Cell® replacement IP-LXM24MK-130 cell pair module – E-Cell® replacement IP-LXM30MK-1
P-180 Upgrade Kit IP-LXMP180
VNX Series Model NumberVNX-X3 IP-VNX-X3VNX50 IP-VNX50
NOTE: 1) The Compact Series replacement modules are also available; Contact Siemens for additional details.2) Please locate the module serial number located on the anode junction box for correct replacement.
84 CONTROL PANELS
H2O Control
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
The H2O Control panel family is a product offering of control panels that include
pump starter panels (single phase up to 2 HP and three phase up to 10 HP) as well
as alarm* and remote alarm* panels. Continuously on lamps are robust LED’s, alarm
lamps are bright visible incandescent bulbs. All panels are UL and cUL Listed. Panels
not specifically listed as part of the product line are also available as custom panels.
• All panels offered as NEMA 4/12, NEMA 4X Composite, NEMA 4X Stainless steel
• Single phase pump starter panels offered as 120 or 220 VAC with options forSimplex, Duplex, and Duplex with alternating timer
• Three phase pump starter panels offered as 208, 230, 460, or 575 VAC with optionsfor Simplex, Duplex, Duplex with alternating timer, auxiliary interclock, alarm
• All wires and screw terminals labeled for easy identification
• Panel drawing provided with each panel
* Alarm and Remote Alarm panels have not been approved for use in dialysis applications.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
1-Phase Pump Starter
3-Phase Pump Starter
Alarm*
Remote Alarm*
85
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
DEAERATORS
Permutit® SLH Deaerating HeatersFlow Rates from 18 to 300 gpm
SYSTEM SPECIFICATIONSModel Number SLH-9 SLH-18 SLH-30 SLH-50 SLH-70 SLH-90 SLH-110 SLH-150
Outlet Capacitylb./hour . . . . . . . . . . . . . . . . . . . . . . . . 9,000 18,000 30,000 50,000 70,000 90,000 110,000 150,000gpm. . . . . . . . . . . . . . . . . . . . . . . . . . . 18 36 60 100 140 180 220 300
Storagelb. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,500 3,000 5,000 8,333 11,667 15,000 18,333 25,000gallons . . . . . . . . . . . . . . . . . . . . . . . . 180 360 600 1,000 1,400 1,800 2,200 3,000
System DimensionsHxDxW
feet . . . . . . . . . . . . . . . . . . . . . . . . . 7x8x10 7x8x13 7x8x17 8x9x18 9x10x17 9x10x20 9x10x28 9x10x27m . . . . . . . . . . . . . . . . . . . . . . . . . . . 17x20x25 17x20x33 17x20x43 20x23x46 23x25x43 23x25x50 23x25x71 23x25x68
Shipping Weightlb.. . . . . . . . . . . . . . . . . . . . . . . . . . . 1,920 2,360 3,010 4,200 5,160 5,860 6,900 8,000kg. . . . . . . . . . . . . . . . . . . . . . . . . . . 871 1,070 1,365 1,905 2,340 2,658 3,130 3,628
Vessels are designed per the ASME Code. Minimum shell and head-plate thickness 1/4". Units with <50,000 lb. capacity are 50 psi ASME Code design pressure. Units with >50,000 lb. capacity are 30 psi ASME Code design pressure.
Permutit® SLH Deaerating Heaters remove oxygen, free carbon dioxide and other
non-condensable gases from make-up water used for boiler feed, as well as from
return condensate. This product combines simplicity and compactness with high
performance and operational efficiency. SLH horizontal deaerating heaters are ideal
for low-pressure boiler plants.
• Compact construction keeps headroom and space requirements to a minimum
• Violent scrubbing action assures complete heating and deaeration
• Maximum efficiency is achieved by preheating water to near steam temperature
• Unique stainless steel internal direct contact vent condenser makes the required
vent rate so low it almost eliminates steam loss
• Simple, inexpensive installation
• Furnished with internal vent condenser and spray valves, inlet control valve,
overflow control, thermometer, sentinel relief valve, pressure gauge, gauge
glasses and structural support
ORDERING INFORMATION
For Permutit® products and information, contact 908-704-9027.
86
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
DEGASIFIERS
DG Series Forced Draft DecarbonatorsFlow Rates from 15 to 400 gpm
DG Series Forced Draft Decarbonators are designed to remove dissolved gases fromprocess water without changing its ambient temperature. The DG Series reducesthe load on deionization equipment and can extend the usable life ofneutralization chemicals and eliminates gas-related problems from the processstream. The DG Series may also be used to oxidize dissolved iron and manganesefor removal by filtration or clarification.
• Large clearwell (storage tank) eliminates the need for additional storage facilities
• Polypropylene hollow sphere packing provides a high active surface area for aircontact with water for rapid and efficient gas removal
• Easy to maintain with removable top for access inside and a packing section
clean-out
• Fiberglass tower with a flat sealed bottom and top air inlet distributor evenlydistribute incoming water over the surface of the packing
• Skid mounted stainless steel transfer pumps are available
• Optional HEPA filters remove airborne particles as small as 0.5 micron
ORDERING INFORMATION
Model
Number Catalog Number Catalog Number Description
DG-12 67/S2201-120 24/S2201-710 HEPA Filter Kit, 120, 180, 240DG-18 67/S2201-180 24/S2201-710 HEPA Filter Kit, 120, 180, 240DG-24 67/S2201-240 24/S2201-710 HEPA Filter Kit, 120, 180, 240DG-30 67/S2201-300 24/S2201-720 HEPA Filter Kit, 300DG-36 67/S2201-360 24/S2201-730 HEPA Filter Kit, 360DG-42 67/S2201-420 24/S2201-740 HEPA Filter Kit, 420DG-48 67/S2201-480 24/S2201-750 HEPA Filter Kit, 480DG-54 67/S2201-540 24/S2201-760 HEPA Filter Kit, 540DG-60 67/S2201-600 24/S2201-770 HEPA Filter Kit, 600
Optional HEPA Filter KitDecarbonators
SYSTEM SPECIFICATIONSModel Number DG-12 DG-18 DG-24 DG-30 DG-36 DG-42 DG-48 DG-54 DG-60
Flow rate . . . . . . . . . . . . . . . . . . . . . . . . . 15 gpm 35 gpm 60 gpm 100 gpm 150 gpm 200 gpm 250 gpm 300 gpm 400 gpmAir at 1' WC (Water Column). . . . . . . . . . 350 cfm 350 cfm 350 cfm 490 cfm 775 cfm 1100 cfm 1375 cfm 1575 cfm 2100 cfmClearwell Capacity. . . . . . . . . . . . . . . . . . 190 gal 259 gal 339 gal 549 gal 677 gal 976 gal 1189 gal 1735 gal 2115 galPacking Volume (cubic ft.). . . . . . . . . . . . 6 15 25 40 55 80 105 130 165
System DimensionsTower Diameter . . . . . . . . . . . . . . . . . . . . 12" 18" 24" 30" 36" 42" 48" 54" 60"Clearwell Diameter . . . . . . . . . . . . . . . . . 3' 3.5' 4' 4.5' 5' 6' 6' 8' 8'Height . . . . . . . . . . . . . . . . . . . . . . . . . . . 13' 14'-6" 15' 16' 16' 16' 17' 16' 17'Operating Weight
lb. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,100 2,700 3,400 5,300 6,200 8,900 10,900 15,900 19,400kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . 953 1,225 1,542 2,404 2,812 4,037 4,944 7,212 8,800
Electrical Requirements . . . . . . . . . . . . . . . 480V/3 phase/60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
87
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
DEIONIZERS
Deionization Recirculating Systems (DIRS)Flow Rates from 5 to 50 gpm
Economical, pre-packaged water purification systems producing high purity water.Depending on water quality requirements, systems are designed to permit several differentfield configurations to accommodate specific requirements. For ease and flexibility ofoperation, the systems are controlled by a PLC integral to the skid. Systems with higherflow rates and/or alternate plumbing options are available with little or no impact todelivery times.• Small skid mounted footprint to conserve valuable floor space
• Schedule 80 PVC piping with optional pigmented polypropylene (PP) for post-treatmentpiping
• Powder-coated steel frames for maximum support of DIRS system while allowing easyaccess for maintenance and operation
• Fully assembled system that is wired and hydrostatically tested prior to shipment
• Complete documentation package including installation, start-up and operationprocedures, P&ID, Electrical Schematics and Quality Assurance data reports
• PLC controls allow for multiple field configurations without altering the control systemhardware
• Fast delivery with pre-manufactured systems
• Quick installation and startup with typically less than one day need for system operation
• Minor field changes permit installation in one of the three configurations shown below
• UL and Seismic Zone 4 compliance to meet regional permitting regulations
Configuration #1
Configuration #2
Configuration #3
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
88
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
DEIONIZERS
VP Series Two Bed DeionizersFlow Rates from 10 to 220 gpm
VP Series Two Bed Deionizers are designed and manufactured for industrialapplications. They are rugged, pre-engineered, pre-assembled, standardized unitsthat minimize expensive installation and start-up costs. VP Series Two Bed Deionizersconsist of an acid regenerated cation vessel piped in series with a causticregenerated anion vessel. These pre-engineered units provide high-quality waterover the length of the service cycle. Operating conditions and an influent wateranalysis are required for predicting effluent quality and total volume of water treatedbefore regeneration is required. To reduce field fit-up problems with interconnectingpiping, the VP Series Two Beds must be ordered with the skid-mounted option.• Simple design maximizes reliability, efficiency and repeatability• 100 psig vessel ratings offer added strength and integrity• Baked PVC lining and paint extend vessel life• PLC controls ensure extremely reliable operation• Inlet flow meter assures consistent performance • Conductivity monitor assures consistent water quality • Schedule 80 PVC piping ensures long life and does not degrade water quality
SYSTEM SPECIFICATIONSDiameter 016 020 024 030 036 042 048 054 060 066 072
Service Flow Rate (gpm) . 10 17 24 38 54 74 97 123 153 182 220Minimum Flow Rate (gpm) 3 4 6 10 14 19 23 31 39 47 55Media (cubic feet)
Cation Resin Volume (ft3) 4 6 10 15 21 28 36 46 57 69 82Capacity (kgr) . . . . . . . . 80 120 200 300 420 560 720 920 1,140 1,380 1,640
AnionResin Volume (ft3) . . . 4.5 7 11 17 24 33 42 54 67 81 96
Capacity (kgr) . . . . . . . . 77 120 190 290 410 560 715 920 1,140 1,380 1,640Pipe Size . . . . . . . . . . . . . . 1” 1” 1” 1-1/4” 1-1/2” 2” 2” 2-1/2” 3” 3” 4”System DimensionsH x L x W . . . . . . . . . .inch 96x56x43 97x64x48 99x72x50 108x84x59 114x96x62 118x108x65 120x120x78 125x132x82 127x144x84 132x156x92 136x168x100
. . . . . . . . . . . . . .cm 244x142x117 246x162x122 251x183x127 274x213x150 289x244x157 300x274x165 305x305x198 317x335x208 322x366x213 335x396x234 345x427x254Shipping Weight
lb (kg) . . . . . . . . . . . . . . . 1800 (817) 2900 (1316) 3800 (1724) 4400 (1996) 6000 (2722) 7860 (3566) 9670 (4387) 11880 (5389) 14880 (6750) 20040 (9090) 25200 (11431)
Electrical Requirements . 120 V/60 Hz/single phase/15 amps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ORDERING INFORMATION
Catalog Number: VPT S XXX X X B P D
System..................................... VPT 016 - 16"x72" 048 - 48"x72"Configuration............................................... S=Simplex* 020 - 20"x72" 054 - 54"x72"
024 - 24"x72" 060 - 60"x72"030 - 30"x72" 066 - 66"x72" A=100 psig 036 - 36"x72" 072 - 72"x72" ASME code Y=Skid, seismic
Vessel Size ............................................................................... 042 - 42"x72" X=100 psig zone 2AVessel Rating .............................................................................................................................................. non-code Z=Skid, seismicVessel Support ......................................................................................................................................................................... zone 4 B=PVC liningLining and Paint......................................................................................................................................................................................................... and paint P=Solid-Controls ................................................................................................................................................................................................................................................. State PLCControl Rating ............................................................................................................................................................................................................................................................... D=NEMA 4/UL*Duplex units should be ordered as two (2) simplex units.To determine your order number, replace the X with one of the numbered options below it.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
89
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
DEIONIZERS
VP Series Mixed Bed DeionizersModel VPMFlow Rates from 16 to 330 gpm
VP Series Mixed Bed Deionizers are designed and manufactured for industrial applications. They are rugged, pre-engineered, pre-assembled, standardized units that minimize expensiveinstallation and start-up costs. Their simple design maximizes the efficiency and repeatabilityof the unit during the service and regeneration modes in order to provide a truly reliablewater treatment unit. VP Series Mixed Bed Deionizers consist of a single vessel that containsboth cation and anion ion exchange resins. The cation resin is a strong acid type. The anionresin is a strong base, Type II. These pre-engineered units provide high-quality water over thelength of the service cycle. Operating conditions and an influent water analysis are requiredfor predicting the effluent quality and total volume of water treated before regeneration isrequired.• Simple design maximizes reliability, efficiency and repeatability• 100 psig vessel ratings offer added strength and integrity• Baked PVC lining and paint extend vessel life• PLC controls ensure extremely reliable operation• Inlet flow meter assures consistent performance• Resistivity monitor assures consistent water quality • Schedule 80 PVC piping ensures long life and does not degrade water quality
SYSTEM SPECIFICATIONSDiameter 016 020 024 030 036 042 048 054 060 066 072
Service Flow Rate (gpm) . . . . . 16 25 36 56 82 112 145 185 229 272 330Minimum Flow Rate (gpm) . . . . 3 4 6 10 14 19 23 31 39 47 55Media (cubic feet)Cation Resin Volume (ft3) . . . . 1.5 2 3 6 9 12 16 21 25 31 37
Capacity (kgr) . . . . . . . . . . . . 30 40 60 120 180 240 320 420 500 620 740Anion Resin Volume (ft3) . . . . . 2.5 4 6 13 18 25 32 41 51 62 73
Capacity (kgr) . . . . . . . . . . . . 25 40 60 130 180 250 320 410 510 620 730Pipe Size . . . . . . . . . . . . . . . . . . 1" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3" 4" 4" 4"System DimensionsH x L x W . . . . . . . . . . . . . .inch 89x48x52 89x51x55 117x54x56 132x57x60 141x63x66 145x70x70 200x78x75 159x90x78 159x96x84 166x106x93 174x117x112 . . . . . . . . . . . . . . . . . . . . . . .cm 226x122x132 226x129x140 297x137x142 335x145x152 358x160x173 368x178x178 508x198x191 404x229x198 404x244x213 422x269x236 442x297x259 Shipping Weightlb (kg) . . . . . . . . . . . . . . . . . . . . 1080 (490) 1750 (794) 2280 (1034) 3000 (1361) 3700 (1678) 4530 (2055) 5330 (2418) 6170 (2799) 7570 (3434) 10080 (4572) 12470 (5657)
Electrical Requirements . . . . 120V/60 Hz/single phase/15 amps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ORDERING INFORMATION
Catalog Number: VPM S XXX X X B P D System . . . . . . . . . . . . . . . . VPM 016 - 16"x72" 048 - 48"x96"Configuration. . . . . . . . . . . . . . . . . . . . . . . . S=Simplex* 020 - 20"x72" 054 - 54"x96"
024 - 24"x72" 060 - 60"x96" X=Legs, seismic030 - 30"x96" 066 - 66"x96" A=100 psig zone 4036 - 36"x96" 072 - 72"x96" ASME code Y=Skid, seismic
Vessel Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 042 - 42"x96" X=100 psig zone 2AVessel Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . non-code Z=Skid, seismicVessel Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . zone 4 B= BakedLining and Paint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PVC P=Solid-Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . State PLC D=NEMA 4Control Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . and UL Label*Duplex units should be ordered as two (2) simplex units.To determine your order number, replace the X with one of the numbered options below it.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
90
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
DEIONIZERS
VP Series Deionizer AccessoriesModel VPZ
VP Series Deionizer accessories provide additional flexibility for mixed bed and two
bed deionizers. These accessories are pre-engineered, pre-assembled catalog units
that are shipped loose for field installation on the deionizer.
Low Flow Recirculation (LFR):The low flow recirculation accessory ensures high water quality from the deionizer when operating at flow rates below the minimum specifiedrate. The recirculation pump automatically runs when the service flow rate drops below the minimum specified rate. The recirculation pump is a316 stainless steel, close-coupled, centrifugal pump with a 115 volt, TEFC motor. Also included is a local control enclosure that is wired directly tothe main control enclosure on the deionizer.
Diameter 016 020 024 030 036 042 048 054 060 066 072
Recirculation Flow Rate (gpm) 3 4 6 10 14 19 23 31 39 47 55Horse Power . . . . . . . . . . . 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 1.0 1.0 1.0Size Code . . . . . . . . . . . . . . 016 020 024 030 036 042 048 054 060 066 072
Effluent Resin Trap (TRP):The effluent resin trap accessory prevents the loss of ion exchange resin from the deionizer vessel in the unlikely event of underdrain failure. Theeffluent resin trap consists of a clear section of PVC pipe with a PVC slotted strainer. The effluent resin trap is installed in the service effluent pipingof the anion or mixed bed vessel.
Diameter 016 020 024 030 036 042 048 054 060 066 072
Mixed Bed Pipe Size . . . . . 1" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3" 4" 4" 4"Mixed Bed Size Code . . . . 100 100 125 150 200 250 300 300 400 400 400Two Bed Pipe Size . . . . . . . 1" 1" 1" 1-1/4" 1-1/2" 2" 2" 2-1/2" 3" 3" 4"Two Bed Size Code . . . . . 100 100 100 125 150 200 200 250 300 300 400
Pressure Reducing Regulator (PRV):The pressure reducing regulator accessory ensures consistent and reliable operation of the deionizer when the feedwater undergoes fluctuationsin pressure. This self-contained regulator is installed on the feedwater inlet of the deionizer.
Diameter 016 020 024 030 036 042 048 054 060 066 072
Mixed Bed Pipe Size . . . . . 1" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3" 4" 4" 4"Regulator Size . . . . . . . . . . 3/4" 3/4" 1" 1-1/4" 1-1/4" 2" 2" 2" 2-1/2" 2-1/2" 3"Mixed Bed Size Code . . . . 075S 075D 100D 125S 125D 200S 200D 200D 250S 250D 300STwo Bed Pipe Size . . . . . . . 1" 1" 1" 1-1/4" 1-1/2" 2" 2" 2-1/2" 3" 3" 4"Regulator Size . . . . . . . . . . 3/4" 3/4" 1" 1-1/4" 1-1/4" 2" 2" 2" 2-1/2" 2-1/2" 3"Two Bed Size Code . . . . . 075S 075D 100D 125S 125D 200S 200D 200D 250S 250D 300S
ORDERING INFORMATION Order as separate items
Catalog Number: VP Z XXX XXXReserved . . . . . . . . . . . . . . . . . . . . . . . . . . Accessory
Size Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See tables for . . . . . . . . . . . . size code
. . . . . . . . . . . . . . . . LFR-Low flow recirculation pump
. . . . . . . . . . . . . . . . TRP-Resin trap
Accessory Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PRV-Pressure reducing regulator
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
91
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
DIALYSIS (HEMODIALYSIS)
Hemodialysis Bicarbonate Mixing andDispensing System
This Siemens Water Technologies system provides consistent bicarbonate mixing and
dispensing. This semi-automatic system reduces the technician’s time and efforts by
automating all operations, especially cleaning. It delivers solution directly to the
distribution loop.
Features that make the difference include:
• Plastic components provide superior corrosion resistance
• Simple, yet rugged construction ensures high reliability
• Pre-assembled, skid-mounted systems reduce installation time and cost
• Programmable Logic Control system meets exacting automatic operational
requirements
• 50 and 100 gallon tank models are available
*Does not include operating space requirements. For easy and safe operation, there shouldbe a minimum of 2ft on each side and 4ft in front of the system.
ORDERING INFORMATIONCatalog Item Part Number
50 GAL TANK. . . . . . . . . . . . BICARB50SYS
100 GAL TANK. . . . . . . . . . . BICARB100SYS
Optional Components Part NumberPressure Control Valve for Distribution Outlet. . . . . . . . . 05/ZIVC00141
Model Number BICARB50 BICARB100
Tank Capacity 50 GAL 100 GAL
Feed 2 GPM@ 30psi
Loop Distribution 4 GPM@ 40psi
Loop Return 4 GPM
Skid Process Connection Specifications
Feedwater Inlet 1/2" NPT
Loop Distribution 3/4" NPT
Loop Return 3/4" NPT
Drain 1" Socket
Utility Requirements
Electrical Service 115 VAC, 1 Phase, 60Hz, 15A
Feedwater RO or DI water produced to AAMI standards for Hemodialysis
Waste Drain (min) 1"
Physical Dimensions Specifications*
Length 70" 83"
Depth 27" 35"
Height 60" 60"
Shipping Weight 300 lbs 350 lbs
Operating Weight 1800 lbs 2500 lbs
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
92
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
DIALYSIS (HEMODIALYSIS)
Med-RO® Reverse Osmosis MedicalSystems RX SeriesFor Dialysis Applications Requiring From 1.5 to 15 gpm
Med-RO® Reverse Osmosis medical systems are specifically designed for hemodialysis water
treatment applications. Our Med-RO® RX Series offers you the greatest flexibility possible
from a standard system. The control system is an easy-to-use advanced microprocessor
based system. The Med-RO® RX series product flow ranges from 1.4 to 15 gpm.
Features that make the difference include:
• Manufactured for hemodialysis water treatment applications, FDA registration
• Easier to clean – “full fit” thin film composite RO membranes mean less bacterial
contamination and less biofilm buildup
• Easy-to-use programmable controls for convenience
• Small footprint requires minimal space
• Reject recycle maximizes water recovery and minimizes waste
• Clean-in-place connections minimize disinfection downtime and overall cleaning time
• Systems manufactured at a QSR/ISO 9001 compliant registered facility
• Used with Siemens registered medical pretreatment components
• Registered with Health Canada as a medical device
General SpecificationsRO Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless steelConductivity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Epoxy coated 3/4” MNPTFlow Indicator (Product) . . . . . . . . . . . . . . . . . . . . . . . . . . . Rotameter, PVC/acrylic construction, 3/4” FPT connectionsFlow Indicator (Reject) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rotameter, PVC/acrylic construction, 3/4” FPT connectionsFlow Indicator (Recycle) . . . . . . . . . . . . . . . . . . . . . . . . . . . Rotameter, PVC/acrylic construction, 3/4” FPT connectionsControl System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Microprocessor, NEMA 4X enclosure
93
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
DIALYSIS (HEMODIALYSIS)
SYSTEM SPECIFICATIONSModel Number RX01 RX02 RX03 RX04 RX05 RX06 RX08 RX09 RX12Product Flow* (gpm) . . . . . . 1.4 2.8 4.0 5.2 6.2 7.0 10.0 12.0 15.0Feed Flow (gpm) . . . . . . . . . 2.8 5.6 8.0 6.9 8.3 9.3 13.3 16.0 20.0Reject Flow (gpm) . . . . . . . . 1.4 2.8 4.0 1.7 2.1 2.3 3.3 4.0 5.0Reject Recycle (gpm). . . . . . 7.0 5.0 4.0 6.0 6.0 6.0 8.0 11.0 10.0
ConnectionFeed Inlet . . . . . . . . . . . . . . . 1-1⁄2” flange 1-1⁄2” flange 1-1/2” flange 1-1/2”” flange 1-1/2” flange 1-1/2” flange 1-1/2” flange 1-1/2” flange 1-1/2” flangeProduct Outlet . . . . . . . . . . . 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPTReject to Drain Outlet . . . . . 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPTWaste Drain–max gpm. . . . . 2.8 5.6 8.0 6.9 8.3 9.3 13.3 16.0 20.0Floor Drain . . . . . . . . . . . . . . A floor drain (in addition to a waste drain) should be supplied for general maintenance
MembranesMembrane/Vessel . . . . . . . . 1 1 1 1 1 1 1 1 1Membrane Quantity . . . . . . . 1 2 3 4 5 6 8 9 12Membrane Type . . . . . . . . . . RO-4040-FF RO-4040-FF RO-4040-FF RO-4040-FF RO-4040-FF RO-4040-FF RO-4040-FF RO-4040-FF RO-4040-FFRO VesselsVessel Array . . . . . . . . . . . . . 1 1:1 1:1:1 1:1:1:1 1:1:1:1:1 1:1:1:1:1:1 2:2:1:1:1:1 3:2:2:1:1 3:3:2:2:1:1Electrical Motor (hp). . . . . . . 5 5 5 5 5 5 10 10 10System Dimensions**H x W x D
inches . . . . . . . . . . . . . . 76x34x42 76x34x42 76x34x42 76x34x42 76x34x42 76x34x42 76x34x42 76x34x42 76x34x42cm. . . . . . . . . . . . . . . . . 193x86x107 193x86x107 193x86x107 193x86x107 193x86x107 193x86x107 193x86x107 193x86x107 193x86x107
Shipping Weight lb (kg) . . . . . . . . . . . . . . 475 (215) 500 (226) 540 (244) 550 (249) 590 (267) 630 (285) 750 (340) 800 (362) 825 (362)
*Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters.**Does not include servicing space requirements.
Med-RO® MODEL
RX Vertical w/ controller, medical RO,
centrifugal pump
RO VESSEL QUANTITY DESIGNATION
01 1 VESSEL
02 2 VESSELS
03 3 VESSELS
04 4 VESSELS
05 5 VESSELS
06 6 VESSELS
08 8 VESSELS
09 9 VESSELS
12 12 VESSELS
RX OPTION DESIGNATIONS
AX 208VAC 3PH 60HZ
BX 230VAC 3PH 60HZ
CX 460VAC 3PH 60HZ
DX 380VAC 3PH 50HZ
EX 575VAC 3PH 60HZ
AX04RXMRO
Med-RO® Part Number Matrix / Single Pass Reverse Osmosis UnitsSTANDARD PRODUCT ORDERING INFORMATION
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Liquid pressure gauges are designed to resist pulsation, shock, vibration, weather and
most corrosive atmospheres. They are ideally suited for a broad range of plant,
hydraulic and fluid power applications.
• Offered with a 2.5" dial face, stainless steel exterior, and liquid filled (glycerine)
with a 1/4" NPT stem mount
• Available with brass or stainless steel internals (gauges used on DI or softened
water must have stainless steel internals)
• Sanitary gauges are 316 stainless steel, glycerine filled and include a 1.5" tri-clamp
connection
ORDERING INFORMATION
Catalog No. Description
PGBR03025 Brass internals; range 0-30 psi
PGBR06025 Brass internals; range 0-60 psi
PGBR10025 Brass internals; range 0-100 psi
PGBR16025 Brass internals; range 0-160 psi
PGSS03025 Stainless steel internals; range 0-30 psi
PGSS06025 Stainless steel internals; range 0-60 psi
PGSS10025 Stainless steel internals; range 0-100 psi
PGSS16025 Stainless steel internals; range 0-160 psi
Catalog No. Description
PGSS40025 Stainless steel internals; range 0-400 psi
PG3A06035 3.5" face; sanitary; 0-60 psi
PG3A10035 3.5" face; sanitary; 0-100 psi
PG3A16035 3.5" face; sanitary; 0-160 psi
PG3A06045 4.5" face; sanitary; 0-60 psi
PG3A10045 4.5" face; sanitary; 0-100 psi
PG3A16045 4.5" face; sanitary; 0-160 psi
94
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
GAUGES
Pressure Gauges
GAUGES
Temperature Gauges
Siemens offers a simple, bimetal temperature gauge designed to measuretemperature in most non-sanitary applications. This gauge is constructedof 304 stainless steel, has a 3" dial face, a 4" long stem, with a 1/2"-14NPT stem mount.
ORDERING INFORMATION
Catalog No. Description
TGNS20030 Non-sanitary; range 0-200°F
95
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
96
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
HIGH PURITY WATER SYSTEMS
PureFit™ High Purity Water Treatment SystemsFlow Rates makeup from 2-20 gpm, recirculating up to 72 gpm
The PureFit™ line of packaged systems is designed to address most common types ofapplications for high purity water with effluent resistivity of 16 megohm-cm orhigher.
PureFit™ systems include pretreatment, deionization, distribution and polishing, aspackaged systems and are offered in a variety of configurations. Each system iscompletely pre-assembled at the factory, with only a few subassemblies that must bereconnected in the field. The only additional items required are service DI (and forHPX, carbon) bottles, that are supplied by the Branch. Equipment can be shipped inwithin 7-8 weeks after receipt of order, and field assembly and startup can often beaccomplished in as little as 1-2 weeks.
HPW: systems with make-up flow rates up to8 gpm feature vertical RO pressure vesselswith one element per housing; systems withmake-up flow rates 12 gpm or higherfeature horizontal RO arrays with three ROelements per housing. An antiscalant feedsystem is available in lieu of softeners on allHPW systems. Equipment layout isextremely compact.
HPC: systems feature many of the samecomponents used in the HPW systems butalso include a softened water break tank andcontinuous electrodeionization instead ofmake-up service deionization. The CDIplatform also includes a UV sterilizer tominimize any biological buildup in therecirculating make-up stream during periodsof low DI water demand.
HPX: systems feature service deionizationinstead of RO as the primary means of TDSreduction. As the SDI units can handle awide range of flow rates a DI water storagetank is generally not required and thesystem footprint can be greatly reduced. Pre-filters and distribution components arecombined on one platform that sits adjacentto SDI and carbon bottles.
97
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
HIGH PURITY WATER SYSTEMS
PureFit™ High Purity Water Treatment SystemsFlow Rates makeup from 2-20 gpm, recirculating up to 72 gpm
Contact a Siemens representative for detailed specifications.In accordance with Siemens policy for continual product development and improvements, we reserve the
right to change the product information within this literature at any time, without notice.
• Powder-coated steel frames
• PLC based control system
• Full factory pre-assembly including piping, wiring, valves, hoses, cartridge filters,and other material items necessary for initial startup in the field
• PVC pretreatment, socket-fusion polyproylene (PP) downstream of the DI storagetank on HPW and HPC systems, PVC post-treatment on HPX systems
• Documentation: Operations & Maintenance Manual, System drawings includingProcess & Instrumentation Diagram and Electrical Schematics
• Fast delivery and installation with pre-manufactured systems
• UL and Seismic Zone 4 compliance to meet regional permitting regulations
98
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
ION EXCHANGE RESINS AND FILTER MEDIA
USF™ Ion Exchange Resin
The selection, application and supply of ion exchange resins are critical to the
performance and cost effectiveness of your water treatment system. For over 80 years,
we have pioneered the development and application of a better ion exchange resin.
Siemens USF™ resin is produced by the leading manufacturers to meet our stringent,
performance based specifications. These standards are higher than those currently
used by the manufacturers in testing their own products. With the purchase of USF™
resin, you are assured of the highest quality product at a competitive price.
Advantages of Choosing USF™ resin:
• Superior quality – resins are tested to meet stringent performance specifications
• Strict QA/QC of our select manufacturers based on their ability to meet the
performance specifications consistently
• Competitive price with lower operating and life cycle costs
• Equal to or better performance for the dosage
• Process performance guarantees available
• Extensive technical and resin application support
• Annual resin analysis – No Charge
• Custom packaging to meet your volume needs
• Certificates of Analysis, Certificates of Conformance and shelf life statements are
available
• QA/QC meets ANSI/ASME NQA-1, 10CFR50 (Appendix B), and 10CFR21
compliance to Nuclear Safety requirements
See page 99 for catalog information.
See page 219 for turnkey ion exchange resin services.
99
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ION EXCHANGE RESINS AND FILTER MEDIA
USF™ Ion Exchange Resin and Media
ORDERING INFORMATIONPlease contact Technical Support at, 800.875.7873 ext 5000 for more information.
Ion Exchange Resins
PRODUCT NAME CATALOG # DESCRIPTION
Strong Acid Cation
USF C-211 (NA) 109104110 8% cross-linked, standard sodium form
USF C-211 (H) 109104111 8% cross-linked, standard hydrogen form
USF C-361 (NA) 109000902 10% cross-linked, more durable cation, sodium form
USF C-361 (H) 109000010 10% cross-linked, more durable cation, hydrogen form
USF C-381 (NA) 109001162 20% cross-linked, macroporous cation, sodium form
USF C-381 (H) 109000050 20% cross-linked, macroporous cation, hydrogen form
Weak Acid Cation
USF C-271 (H) 109004281 Acrylic weak acid cation macroporous, hydrogen form
Strong Base Anion
USF A-244 (CL) 109151000 Type II strong base, gel standard anion, chloride form
USF A-284 (CL) 109167502 Type I strong base, gel standard anion, chloride form
USF A-464 (CL) 109183201 Type I strong base, porous gel standard anion, chloride form
USF A-674 (CL) 109001160 Type I strong base, macroporous standard anion, chloride form
USF A-714 (CL) 109004968 Strong base acrylic gel anion, chloride form
Weak Base Anion
USF A-399 (FB) 109183401 High capacity styrenic macroporous weak base anion, free base form
USF A-444 (FB) 109000706 High capacity acrylic gel weak base anion, free base form
MEG Grade Resins
Cation
USF C-361 MEG (H) 3R010002910% cross-linked cation, hydrogen form, specially processed to meet tight semiconductor industry requirements
USF C-361 MEG PPQ (H) 3R0100028 Extremely low sodium processed upgrade of the C-361 MEG (H).
Anion
USF A-464 MEG (OH) 3R0100652Type I strong base, porous gel anion, hydroxide form, specially processed to meet tight semiconductor industry requirements
USF A-464 MEG PPQ (OH) 3R0100653 Extremely low sodium processed upgrade of the A-464 MEG (OH).
Mixed Bed
USF NR-30 MEG 3R0101082 1:1 chemical equivalent mix of C-361 MEG (H) and A-464 MEG (OH)
USF NR-30 MEG PPQ 3R0101086 1:1 chemical equivalent mix of C-361 MEG PPQ (H) and A-464 MEG PPQ (OH)
100
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
ION EXCHANGE RESINS AND FILTER MEDIA
USF™ Ion Exchange Resin and Media
Filter Media and Activated Carbon
Quartz
USF No. 20 Quartz 110001500 Underlayment support bed and/or filter media: 0.4-0.5 mm
USF No. 7 Quartz 110001401 Underlayment support bed and/or filter media: 0.75-0.85 mm
USF No. 4 Quartz 110001302 Underlayment support bed and/or filter media: 1.50-1.60 mm
USF 1/4 x 1/8 Quartz 110001203 Underlayment support bed and/or filter media: 3.2-6.4 mm
USF 1/2 x 1/4 Quartz 110001104 Underlayment support bed and/or filter media: 6.4-12.7 mm
USF 3/4 x 1/2 Quartz 110001005 Underlayment support bed and/or filter media: 12.7-19.1 mm
Garnet
USF No. 8 Garnet 110400002 Filter media: 2.10-2.50 mm
USF No. 8-12 Garnet 110400000 Filter media: 1.41-2.00 mm
USF No. 30-40 Garnet 110400001 Filter media: 0.35-0.50 mm
Manganese Greensand
USF Greensand 110201001 Manganese greensand used for iron removal
Anthracite
USF Anthrafilt 110100997 Coarse filter media
Activated Carbon
USF ORC Carbon 110350006 12x40 mesh bituminous activated carbon
USF Acid Washed Carbon 110350008 Acid washed 12x40 mesh bituminous activated carbon
USF Coconut Shell Carbon 110350009 Coconut Shell 12x40 mesh activated carbon
ORDERING INFORMATIONPlease contact Technical Support at, 800.875.7873 ext 5000 for more information.
101
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ION EXCHANGE RESINS AND FILTER MEDIA
USF™ Ion Exchange Resin and MediaCross Reference Guide
ORDERING INFORMATIONPlease contact Technical Support at, 800.875.7873 ext 5000 for more information.
Siemens is the largest distributor of ion exchange resin. We are able to supply
you resin from all of the leading manufacturers, and are the largest stocking
distributor of Dowex brand resin.
UUSSFF™™ BBrraannddAmberlite Rohm &
HaasLewatit
LANXESSIonac® Sybron
Diaion®Mitsubishi
Dowex® Dow Purolite®
Weak Acid Cation
USF C-271 IRC-76 CNP-80MAC-3
(Marathon® MAC-3)C-106
USF C-281 IRC-86 CC WK-40 C-105
Strong Acid Cation
USF C-211IR-120
(Amberjet® 1200)(MonoPlus® S-100) C-249 SK-1B
HCR-S (Marathon® C)
C-100
USF C-361IR-122
(Amberjet® 1500)(MonoPlus® S-200) C-250 SK-110
HGR-W2 (Marathon® C-10)
C100X10
USF C-381 IR-200 (MonoPlus® SP-112) PK-228 (Marathon® MSC) C-150
Weak Base Anion
USF A-399 IRA-96 (MonoPlus® MP-64) WA-30 (Marathon® WBA-2) A-100
USF A-444 IRA-67 VP OC 1072 A-845
Strong Base Anion
USF A-244IRA-410
(Amberjet® 4600)(MonoPlus® M-600) ASB-2 SA-20A
SAR (Marathon® A2)
A-300
USF A-284IRA-400
(Amberjet® 4200)(MonoPlus® M-500) ASB-1 SA-10A
SBR-C (Monosphere® 550A)
A-600
USF A-464IRA-402
(Amberjet® 4400)ASB-1P SA-12A
SBR-P (Marathon® A)
A-400
USF A-674 IRA-900 (MonoPlus® MP-500) A-641 PA-312 (Marathon® MSA) A-500
A-714 IRA-458 VP OC 1071 A-850
Mixed Bed
USF TM-9 NRW-37
USF EDM
USF NR-6 IRN-150 SM 94 NM-60 (Marathon® MR-3)
USF NR-14 NM-73 NRW-37
USF NR-30 EX MB
( ) indicates Uniform Particle Size Equivalent
102
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
Resin Capacity (ft3) 0.45 1.2 3.5 12 30
Flow Rate (Min.–Max.) 0.5–1 1–3 2–10 10–35 25–75
Dimensions, Base/Height 8”dia./20.5” 8”dia./48” 14”dia./50” 29”sq./71.5” 36”sq./75.5”
ION EXCHANGE WASTEWATER SYSTEMS
Wastewater Ion Exchange Systems
ORDERING INFORMATIONFor more information, contact 800.525.0658.
Siemens Water Technologies designs and maintains systems to purify metal finishing
rinses, contaminated groundwater, printed circuit board rinses and many other metal
bearing streams. Siemens’ Wastewater Ion Exchange (WWIX) service utilizes ion
exchange resins and other media selected to remove specific ionic contaminants from
groundwater, industrial wastewater, and process water for recycle. DOT approved
vessels containing the selected resin or media treat your water until the capacity is
reached. Once exhausted, the WWIX vessels are removed and replaced with fresh, DOT-
compliant vessels and returned to service. Exhausted vessels are returned to our
processing facility where the contaminants are removed from the media/resin.
Your specific requirements are evaluated on an individual basis to determine the system configuration that best meets
your current and future needs. The system components are selected based upon your specific reuse or discharge
requirements. If your needs change, our wastewater treatment systems are flexible – we can simply change the media
types and/or tank size saving you significant capital expense.
Systems include resin/media options matched to your treatment needs:
• Granular Activated Carbon – Removes potential organic foulants as pretreatment to
the resins
• Strong Acid Cation Resin – Removes soluble cations (Ca, Ni, Zn, Mg, Cu, etc.)
• Strong Base Anion Resins – Removes soluble anions (SO4, Cl, CN, Cr6, etc.)
• Mixed Bed Resin – For polishing of low level dissolved ionic waters (e.g. rinse applications)
• Metals Specific Resins – For removal of specific metals (Cu, As, Zn, etc.)
• Lead Resins – For removal of Pb from wastewaters (sacrificial media)
Siemens national service network provides the local service needed to simplify the operation of your WWIX system. A
simple phone call is all that is required to get fresh canisters delivered to your site and the spent units picked up and
returned to our RCRA permitted plant for processing. All of our tanks are DOT approved for the transportation of
hazardous waste. See page 217 for more details on this service.
103
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ION EXCHANGE WASTEWATER SYSTEMS
AquaSaver™ Chemical Feed and Pump Skids
SPECIFICATIONS
Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 75 gpmpH Monitor . . . . . . . . . . . . . . . . . . . . . . . . Strantrol® 880PLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Allen-Bradley®Chart Recorder . . . . . . . . . . . . . . . . . . . . . OptionalChemical Pumps . . . . . . . . . . . . . . . . . . . Siemens or LMI®Alarms Beacon and Audible Alarm for out of spec conditions
ORDERING INFORMATIONFor more information, contact 800.525.0658.
AquaSaver™ control skids are totally integrated, skid-mounted treatment
stations for pre ion-exchange water conditioning. The pH Contol Skid adjusts
the pH to the proper level before transfer to the ion exchange system, while
the Booster Skid supplies consistent process water flow and pressure,
optimizing the operation of downstream ion-exchange systems.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
104
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
PURELAB® UltraWater Purification System
PURELAB® ULTRA SYSTEM SPECIFICATIONS
Performance Specifications*
MODEL Resistivity Flow Rate (lpm) TOC (ppb) EndotoxinsEU/ml
BacteriaCFU10/ml
PURELAB Ultra Scientific
PURELAB Ultra Ionic
PURELAB Ultra Analytic
PURELAB Ultra Bioscience
PURELAB Ultra Genetic
18.2
18.2
18.2
18.2
18.2
up to 2.0
up to 2.0
up to 2.0
up to 2.0
up to 2.0
3-10
3-10
1-2
3-10
1-3
NA
NA
NA
<0.001
<0.001
<1**
<1
<1
<1
<1
MODEL HxWxD (in) Weight lbs
PURELAB Ultra Scientific
PURELAB Ultra Ionic
PURELAB Ultra Analytic
PURELAB Ultra Bioscience
PURELAB Ultra Genetic
19x16x14
19x16x14
19x16x14
19x16x14
19x16x14
System Dimensions
Feed Water ParametersPurification Technology
MODEL DualPurificationCartridges
UV 254nm UV254/185nm
UF Ultrafilter
UMF UltraMicrofilter
PURELAB Ultra Scientific l
PURELAB Ultra Ionic l l l
PURELAB Ultra Analytic l l l l
PURELAB Ultra Bioscience l l
PURELAB Ultra Genetic l l l l
TOCMonitor
* Specifications based on RO pretreatment** < 1 CFU/ML w/0.2µm filter
Maximum Fouling Index <1*
Maximum Conductivity (RO Feed) 50 µS/cm
Minimum Resistivity (SDI Feed) 1 MΩ-cm
Maximum TOC 50 ppb
Maximum Free Chlorine <0.05 ppm
Maximum Carbon Dioxide 30 ppm
Maximum Silica 2 ppm
Particulates Down to 0.2 µm filtration
Temperature 1-40 °C
Feedwater Flow Rate Maximum requirement 130 lph
Maximum Pressure 10 psi
Minimum Pressure 1 psi or flooded suction to the recirculation pump
Power Requirements 100-240 VAC, 50-60 Hz (all models)
*A 0.2µm prefilter recommended for all non-RO feeds.
38
39
40
39
40
State-of-the-art intelligent water system delivers ASTM Type I ultrapure water for
critical biological and analytical applications. Designed to ensure the highest quality
water with the most advanced smart monitoring system.
Standard Features and Benefits
• 18.2 Megohm purity water up to 2.0 lpm
• Direct on-line real time TOC monitoring (Analytic and Genetic)
• Unique CID (cartridge identification) technology provides full traceability and
history of purification cartridge packs for validation
• 5 models to choose from
• Worker polisher purification design reduces annual costs by 50%
• Programmable dispense with auto alarm and shut off prevents flooding
• Volumetric Profile Memory dispense
• Friendly consumable change-out reminders
105
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB® UltraWater Purification System
Consumables and Accessories
Sanitization Tablets
UV Lamp 254nm (for Ionic)
UV Lamp 185nm/254nm
Ultra microfilter (0.05µm)
Ultrafilter (5,000 MWCO)
Point-of-Use Filter (0.2µm)
Labpure S1 DI Cartridge-RO Feed
Labpure S2 DI Cartridge-SDI Feed
Labpure S3 DI Cartridge-Low Ionic
Labpure S4 DI Cartridge-Low TOC
CT1
LC105
LC118
LC109
LC151
LC134
LC182
LC183
LC184
LC185
PURELAB® Ultra SystemsORDERING INFORMATION
Service and Maintenance packages availableDI (Deionization) Cartridges must be ordered separately
MODEL Catalog Number
PURELAB Ultra Scientific
PURELAB Ultra Ionic
PURELAB Ultra Analytic
PURELAB Ultra Bioscience
PURELAB Ultra Genetic
PURELAB Ultra Analytic under-benchsystem (with remote control station anddispense gun)
PURELAB Ultra Genetic under-benchsystem (with remote control station anddispense gun)
ULXXXSCM2
ULXXXIOM2
ULXXXANM2
ULXXXBSM2
ULXXXGEM2
ULRSXANM2
ULRSXGEM2
Consumables Accessories
Pressure Regulator Valve Inlet
Wall Mounting Kit (PURELAB Ultra Unit)
RS232 Printer Kit
Installation Kit (PURELAB Ultra Unit) (supplied)
Remote Dispense Station (including dispense gun)
Integral Dispense Gun (PURELAB Ultra Unit)
Remote Control Station (PURELAB Ultra Unit)
Open Circuit Ring Main Kit
Closed Circuit Ring Main Kit
Pressure Regulator <60 psd
SDIRG2613*
LA622USA
LA618
LA642
LA643
LA644
LA645
LA646
LA647
LA652
Storage reservoirs are located on pages 34.* For feed pressure above 60 psig, use pressure regulator LA575.
Note: Installation kit supplied with all Ultra systems
Invitro Fertilization
2D Electrophoresis
Glassware washing
HPLC
Immunology
Tissue Culture
GC/MS
Toxicology
Buffer Preparation
Microbiology
DNA/RNA Research
Endotoxin analysis
TOC Analysis
MonoclonalAntibody production
Protein/Peptide Sequencing
Ion Chromatography
Flameless AA
PCR
ICP-MS
Protein purification
Mammalian Cell Culture
PURELAB UltraScientific
PURELAB UltraIonic
PURELAB UltraAnalytic
PURELAB UltraBioscienceApplications
Atomic Absorption
ICP-ES
PURELAB UltraGenetic
PURELAB® Systems Validation SupportSiemens Water Technologies offers validation documentation support packages for allPURELAB® Ultra water purification products. Validation support manuals includeInstallation Qualification (IQ), Operational Qualification (OQ) documentation and otherquality certification as required to complete validation of the water system. Our serviceengineers are fully trained to perform certification as required to complete thevalidation of water system.
ll
ll
l
ll
l
l
ll
ll
lll
ll
l
ll
l
l
106
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB® Classic Water Polishing Systems
Cost-efficient alternative for ASTM Type I purity water for general analytical and biological
applications. The PURELAB® Classic System offers reliability, and uncompromising
water quality.
Standard Features and Benefits
• 18.2 Megohm purity water up to 1.5 lpm
• Easy front loading cartridges
• Complete sanitization of all wetted parts
• Unique CID Technology provide full traceability and history of purification
cartridge packs for validation
• Dual wavelength UV — 185 nm and 254 nm (PURELAB Classic UV Model)
• 5000 Dalton UF Module for pyrogen removal (PURELAB Classic UF Model)
• Wall or bench mountable
• Applications include HPLC, ICP, ICP/MS, GC, IC, AA, cell culture and molecular
biology
PURELAB® CLASSIC SYSTEMS
System Specifications
MODEL Resistivity Flow Rate†(lpm)
TOC* (ppb)
Endotoxins**EU/ml
Bacteria** CFU/ml
PURELAB Classic DI
PURELAB Classic UV
PURELAB Classic UF
PURELAB Classic UV/UF
18.2
18.2
18.2
18.2
1.5
1.5
1.5
1.2
<3-10
<1-3
<3-10
<1-3
NA
NA
<.001
<.001
<1
<1
<1
<1
MODEL HxWxD(in)
Weight(lbs)
Inlet Connections PowerRequirements
PURELAB Classic DI
PURELAB Classic UV
PURELAB Classic UF
PURELAB Classic UV/UF
19x16x14
19x16x14
19x16x14
19x16x14
32
33
32
33
8mm (5/16”) OD-Quick Connect
8mm (5/16”) OD-Quick Connect
8mm (5/16”) OD-Quick Connect
8mm (5/16”) OD-Quick Connect
110–240 V 50/60 Hz
110–240 V 50/60 Hz
110–240 V 50/60 Hz
110–240 V 50/60 Hz
System Dimensions
MODEL OperatingTemperature
InletPressure
Free Chlorine(ppm)
PURELAB Classic DI
PURELAB Classic UV
PURELAB Classic UF
PURELAB Classic UV/UF
1–40˚ C
1–40˚ C
1–40˚ C
1–40˚ C
1–10 psig
1–10 psig
1–10 psig
1–10 psig
<0.05
<0.05
<0.05
<0.05
Feed Water Parameters
* Depends on feed water conditions. ** Based on regular sanitization and proper maintenance of the system.† Based on 1 bar feed pressure.
107
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Accessories
Chlorine Sanitization Tablets
Labpure S5 DI Cartridge
UF Membrane
UV Lamp 185/254 nm
0.2 µm Final Filter
CT1
LC186
LC169
LC170
LC134
PURELAB® CLASSIC SYSTEMORDERING INFORMATION
Purification Cartridges must be ordered separately. UF cartridge and UV lamp supplied.
MODEL Catalog Number
PURELAB Classic DI
PURELAB Classic UV
PURELAB Classic UF
PURELAB Classic UV/UF
CLXXXDIM2
CLXXXUVM2
CLXXXUFM2
CLXXUVFM2
Integral Dispense Gun
Remote Dispense Station
Printer Kit
Sanitization by-pass block
Pressure Regulator Valve (Feed Water Pressures
>4 bar (60 psi))
Pressure Regulator Valve (Feed Water Pressures
>0.7 bar (10 psi))
Pressure Regulator <60 psi
Wall Mount Kit
Remote Dispense Station with Dispense Gun
Open Ring Main Kit
Closed Ring Main Kit
Installation Kit
Composite Vent Filter
LA644
LA645
LA618
LA698
LA575
LA652
SDIRG261
LA622USA
LA643
LA646LA647LA642LC136M2
LABORATORY WATER SYSTEMS
‘
PURELAB® Classic Water Polishing Systems
Consumables
108
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB® UHQ Systems
Lightweight, compact, portable ultrapure water system for the modern laboratory requiring up to
15 liters per day of 18.2 Megohm ASTM Type I water. The PURELAB® UHQ System delivers
ultrapure water from a tap feed or pretreated feed source for demanding laboratory applications.
Standard Features and Benefits
• 18.2 Megohm purity water up to 0.75 lpm
• Recirculation feature maintains optimum water quality and inhibits bacterial growth
• Specially conditioned ion exchange resin ensures absolute ionic purity
• UV reactor cell reduces microorganisms and TOC levels
• 0.05 µm absolute filter protects microbore columns in analytical instruments
• Quality meter continually displays resistivity of water
• 4 liter storage tank capacity
• Supplied complete with all consumables
PURELAB® UHQ SYSTEM SPECIFICATIONS
Performance Specifications
MODEL TOC (ppb) Particles Output/per 8 hr daywhen fed w/RO water
BacteriaCFU/ml
PURELAB UHQ II w/RO
PURELAB UHQ PS w/out RO
<20
<20*
<0.05 µm
<0.05 µm
15 liters
25–40 liters
<1
<1
MODEL HxWxD (in) Shipping Weight (lbs) Inlet Connections Power Requirements
PURELAB UHQ II
PURELAB UHQ PS
16x9x16
16x9x16
22
22
3/4" NPT or 3/8" tube
3/4" NPT or 3/8" tube
110/115 V 60 Hz
110/115 V 60 Hz
System Dimensions
MODEL Operating Temperature Inlet PressureFeedwater quality
PURELAB UHQ II
PURELAB UHQ PS
4–35˚ C
4–35˚ C
Max 90 psi/Min 30 psi
Max 90 psi/Min 30 psi
Potable water free from turbidity & organics (max. freechlorine <0.1 ppm
Prepurified, <20 µS/cm and filtered to 0.2 µm or less
PURELAB® UHQ Feed Water Parameters
* When fed with reverse osmosis (RO) water
PURELAB® UHQ SYSTEMSORDERING INFORMATION
MODEL Catalog Number
PURELAB UHQ II Type I water system w/RO
PURELAB UHQ PS Type I water system w/out RO
UHQ000IIXX11503
UHQ000PSXX11503
Consumables and Accessories
Purification Pack (2 organic absorption cartridges and 2 ion exchange cartridges)
Reverse Osmosis Cartridge
0.05 µm Ultra Microfilter
UV Lamp
Composite Vent Filter
UHQPACKA
UHQ5
LC109
LC104
UHQ4
HPLC
Atomic AbsorptionSpectroscopy
ICP/MS
Ion Chromatography
PURELABUHQ II
PURELABUHQ PSApplication
l l
l l
l l
l l
109
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
MODULAB® High Flow Systems
MODULAB® HIGH FLOW SYSTEMS
Ordering Information
MODEL # PRODUCT
MHF0ORG1
MHF0SMF2
MHD0SMF5
CARTRIDGES
MLHF20DI01
MLHF20CAR1
MLHF20OS01
FCUF020S2 (1/PK)
MLMF020S2 (2/PK)
FCUF020S05
CONSUMABLES
BULBUV185
MLHFTOC1KIT
MLHFB102
MLHFUF05
Modulab High Flow System Low TOC
Modulab High Flow System Bio Model
Modulab High flow System UF Model
Carbon Cartridge
Mixed Bed Cartridge
Organic Removal Cartridge
0.2 µm, Filter Cartridge
0.2 µm, Filter Cartridge
0.05 µm, Micro Ultrafilter Cartridge
UV Lamp
Start-up Kit (Low TOC)
Start-up Kit (Bio Model)
Start-up Kit (UF Model)
General SpecificationsOperating Parameters
MODULAB® System SpecificationsProduct Water Quality
Modular polishing system provides up to 18.2 Megohm quality water on demand.
The MODULAB® High Flow System is offered in three models: low TOC (Total
Organic Carbon), low bacteria, low pyrogen systems.
Features and Benefits
• High capacity, low TOC cartridges
• Flow rates up to 14 lpm
• Dual wavelength UV sterilization
• Wall mountable
• Up to 18.2 MΩ-cm water
Min. Flow Rate
Max Flow Rate
Resistivity
Total Organic Carbon (TOC)
Heavy Metals
Bacteria
Endotoxin
2 lpm (0.5 gpm)
Up to 14 lpm (3.7 gpm)
Up to 18.2 MΩ-cm @ 25˚C
<15 ppb*
<0.10 ppb
<10 cfu/ml**
<0.05 EU/ml**
* With organic Removal Cartridge installed and RO (reverse osmosis) feed water.** With Sub-micron or UF (ultrafiltration) Filter Cartridge installed as specified.Note: Specifications are based on a RO feed with recirculation.
Min Feed Pressure
Max Feed Pressure
Min Feed Temperature
Max Feed TemperaturePhysical Specifications
Length, in (cm)
Depth, in (cm)
Height, in (cm)
UV Bulb Service Clearance, in (cm)Utility Requirements
Electrical
Low voltage service, Single Phase
Breaker required per Code
Feed Water
0.5 psig
60 psig
41˚F (5˚C)
100˚F (37.7˚C)
43 (109)
8.5 (22)
39 (100)*
6 (16) Front
115 VAC
15 AMP
RO or DI water
* Requires an additional 4” in height to allow changing of cartridges
110
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB®
Option-S Water Purifiers
The PURELAB® Option-S System combines pretreatment, reverse osmosis, and ionic/organic
removal in a single unit to deliver better than single distilled quality water from a potable water
source. With 4 models to choose from, the PURELAB® Option-S System is ideally suited for
general laboratory analyses and as pretreatment to ultrapure water polishing units.
Standard Features and Benefits
• Up to 10 Megohm purity water
• Easy front loading cartridges
• Cartridge change indicator
• Microprocessor controlled system management with continuous water quality
monitoring
• Data collection capabilities through RS232 interface
• Adjustable audio-visual alarms
• Upgradable to higher flow rates
• Wall or bench mountable
• Supplied complete with all consumables
PURELAB® OPTION-S SYSTEM SPECIFICATIONS
Performance Specifications
MODEL Resistivity MΩ-cmFlow Rate
LPH @ 25˚ CTOC (ppb)
Bacteria*CFU/ml pH
PURELAB Option-S 7/15
PURELAB Option-S 30/60
1–10
1–10
7 or 15
30 or 60
<30
<50
NA
<1
Neutral
Neutral
MODEL HxWxD (in) Weight (lbs) Power Requirements
18.2x16.2x8.3
18.2x16.2x8.3
29.2x22.5x12.6
29.2x22.5x12.6
110–240 V 50- 60 Hz
110–240 V 50- 60 Hz
110–120 V 60 Hz
110–120 V 60 Hz
System Dimensions
MODEL FeedWater
MaximumFI
Max.Conductivity
µS/cm
Max.Free Chlorine
(ppm)
PURELAB Option-S 7/15
PURELAB Option-S 30/60
Potable
Potable
10
10
1400
1400
<0.5
<0.5
Feed Water Parameters
* Based on regular sanitization and proper maintenance of the system
Max. Pressurew/out booster
pump (psi)Temperature
Max. Pressurew/boosterpump (psi)
1–35˚ C
1–35˚ C
90
N/A
30
N/A
GlasswareWashing/Rinsing
Reagent Preparation
Buffer Preparation
General Chemistry
Qualitative Analyses
Feed to EnvironmentalCabinets
PURELABOption-S 7/15
PURELABOption-S 30/60Application
29.8
32
114.6
116.8
PURELAB Option-S 7
PURELAB Option-S15
PURELAB Option-S 30
PURELAB Option-S 60
*Fouling Index
l
lllll
l
lllll
111
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB®
Option-S Water Purifiers
Consumables and Accessories
Pretreatment Cartridge
RO module (7.5 lph)
Purification Cartridge
Composite Vent Filter
Wall Mounting Bracket
Chlorine Sanitization Tablets
Pressure Regulator Valve
Booster Pump Kit
Flow Upgrade Kit (7–15 lph)
RS232 Printer Kit
Remote Control Station
Installation Kit (supplied)
Remote Dispensing Valve
LC140
LC143
LC141
LC136M2
LA622USA
CT1
LA512
LA609
LA604
LA618
LA624 (7/15 units only)
LA513
LA521
Option-S 7/15 Option-S 30/60
5 µm Carbon Filter
RO Module (30 lph)
RO Module (60 lph)
Purification Cartridge
UV Lamp
Wall Mounting Bracket
Cleaning Solution Elgalite RF
Flow Upgrade Kit 30–60 lph
Installation Kit (supplied)
LC123
LC115
LC119
LC114
LC105
LA593USA
SOLU30966
LA562
LA545
Storage Reservoirs - Required with system
25 Liter Reservoir
40 Liter Reservoir
75 Liter Reservoir
DV 35 Docking Vessel
DV 35 Liter Mounting Bracket
Wall Mounting Kit (25/40 Liter Reservoir)
Wall Mounting Kit (75 Liter Reservoir)
LA611
LA612
LA613
LA620
LA591USA
LA591USA
LA592USA
Option-S 7/15 Option-S 30/60
40 Liter Reservoir
75 Liter Reservoir
Wall Mounting Kit (25/40 Liter Reservoir)
Wall Mounting Kit (75 Liter Reservoir)
LA587
LA590
LA591USA
LA592USA
PURELAB® OPTION-S SYSTEMORDERING INFORMATION
*Reservoir is required with Option-S (sold separately - see below)All units come complete with installation kit and full set of cartridges
MODEL Catalog Number
PURELAB Option-S 7
PURELAB Option-S 7 w/booster pump
PURELAB Option-S 15
PURELAB Option-S 15 w/booster pump
PURELAB Option-S 30
PURELAB Option-S 60
OS007XXM1
OS007BPM1 (for feed waters less than 60 psi)
OS015XXM1
OS015BPM1 (for feed waters less than 60 psi)
OPT030XXXX11503
OPT060XXXX11503
Note: Installation kit is supplied with DV Reservoirs
112
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB®
Option-R Water Purifiers The PURELAB® Option-R System features all the technologies of the S series units with the
added benefit of an integral recirculation feature to deliver better than double distilled
quality water from a potable water source. The PURELAB® Option-R System is ideally suited
for standard laboratory techniques and as pretreatment to ultrapure water polishing units
where TOC is a concern.
Standard Features and Benefits
• 10 to 15 Megohm purity water
• Easy front loading cartridges
• Cartridge change indicator
• Microprocessor controlled system management with continuous water quality
monitoring through unique GRID display (Option-R 7/15)
• Data collection capabilities through RS232 interface
• Adjustable audio-visual alarms
• Upgradable to higher flow rates
• Wall or bench mountable
• Supplied complete with all consumables
PURELAB® OPTION-R SYSTEM SPECIFICATIONS
Performance SpecificationsMODEL Resistivity
MΩ -cmFlow Rate
LPH @ 25˚ CTOC*(ppb)
Bacteria*CFU/ml
pH
PURELAB Option-R 7/15
PURELAB Option-R 30/60
10 to >15
1 to >15
7/15
30/ 60
<20
<50
<1
<1
Neutral
Neutral
MODEL HxWxD (in) Weight (lbs) Power Requirements
PURELAB Option-R 7/15
PURELAB Option-R 30/60
18.2x16.2x8.3
29.2x22.5x12.6
R7–39.8 : R15–41.9
R30–116.8 : R60–119
110–240 V 50- 60 Hz
110–120 V 60 Hz
System Dimensions
MODEL Feedwater MaximumFI*
Max.Conductivity
µS/cm
Max. FreeChlorine
(ppm)
PURELAB Option-R 7/15
PURELAB Option-R 30/60
Potable
Potable
10
10
1400
1400
<0.5
<0.5
Feed Water Parameters
* Based on regular sanitization and proper maintenance of the system
Pressure w/out booster pump (psi)
Temperature Pressure w/boosterpump (psi)
1–35˚ C
1–35˚ C
90 max/60 min.
NA
30 max/flooded suction
NA
Particulates
>0.2 µm
>0.2 µm
GlasswareWashing/Rinsing
Cytology & HistologyPreparations
Immuno-Cytochemistry
Spectrophotometry
Electrophysiology
Electrochemistry
PURELABOption-R 7/15
PURELABOption-R 30/60Application
RIA/ELISA
General Purpose HPLC
Flame AA
* Fouling Index
l
l
lllllll
l
l
lllllll
113
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB®
Option-R Water Purifiers
Consumables and Accessories
Pretreatment Cartridge
RO module (7.5 lph)
Purification Cartridge
Composite Vent Filter
Point-of-Use Filter (0.2µm)
UV Lamp
Wall Mounting Bracket
Chlorine Sanitization Tablets
Pressure Regulator Valve
Booster Pump Kit
Flow Upgrade Kit (7 to 15 lph)
RS232 Printer Kit
Remote Control Station
Remote Dispensing Gun
Installation Kit (supplied)
LC140
LC143
LC141
LC136M2
LC145
LC105
LA622USA
CT1
LA512
LA609
LA604
LA618
LA625 (7/15 units only)
LA629 (7/15 units only)
LA513
Option-R 7/15 Option-R 30/60
5 µm Carbon Filter
RO Module (30 lph)
RO Module (60 lph)
Purification Cartridge
Point-of-Use Filter
UV Lamp
Wall Mounting Bracket
Cleaning Solution Elgalite RF
Flow Upgrade Kit 30 to 60 lph
Installation Kit (supplied)
LC123
LC115
LC119
LC114
LC106
LC105
LA593USA
SOLU30966
LA561
LA545
Storage Reservoirs - Required with system
25 Liter Reservoir
40 Liter Reservoir
75 Liter Reservoir
DV 25 Liter Docking Vessel
DV 25 Liter Mounting Bracket
Composite Vent Filter
Wall Mounting Kit (25/40 Liter Reservoir)
Wall Mounting Kit (75 Liter Reservoir)
LA611
LA612
LA613
LA621
LA591USA
LC136M2
LA591USA
LA592USA
Option-R 7/15 Option-R 30/60
40 Liter Reservoir
75 Liter Reservoir
Composite Vent Filter
Wall Mounting Kit (25/40 Liter Reservoir)
Wall Mounting Kit (75 Liter Reservoir)
LA587
LA590
LC136M2
LA591USA
LA592USA
PURELAB® OPTION-R SYSTEMORDERING INFORMATION
*Reservoir is required with Option-R (sold separately)All units come complete with installation kit and full set of cartridges
MODEL Catalog Number
PURELAB Option-R 7
PURELAB Option-R 7 w/booster pump
PURELAB Option-R 15
PURELAB Option-R 15 w/booster pump
PURELAB Option-R 30
PURELAB Option-R 60
OR007XXM1
OR007BPM1 (for feed waters less than 60 psi)
OR015XXM1
OR015BPM1 (for feed waters less than 60 psi)
OPT030PLXX11503
OPT060PLXX11503
114
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB®
Option-Q Water Purifiers
The PURELAB® Option-Q System produces ultra pure water with out the need for a pre-
purified feed supply. Available in two models depending on flow rate requirements, the
PURELAB® Option-Q System delivers up to 18 Megohm water on demand direct from tap
making it a cost effective choice for the laboratory.
Standard Features and Benefits
• Up to 18.2 Megohm water from tap
• Cartridge change indicator to ensure optimal performance
• Easy front loading cartridges
• Adjustable audio-visual alarms for consumable change-outs
• RS232 interface for easily downloaded data collection
• Compact Design
• Comes complete with all consumables
PURELAB® OPTION-Q SYSTEM SPECIFICATIONS
Performance SpecificationsMODEL Resistivity
at 25˚CTOC(ppb)
Bacteria* CFU/ml withPOU Filter (optional)
pH
PURELAB Option-Q 7/15 Up to 18.2 MΩ-cm <10 <1 Effectively Neutral
MODEL HxWxD (in) Weight (lbs)
PURELAB Option-Q 7
PURELAB Option-Q 15
18.1x21.7x10.5
18.1x21.7x10.5
39.7
41.8
System Dimensions
MODEL Feedwater MaximumFI*
Max.Conductivity
µS/cmMax. FreeChlorine
PURELAB Option-Q 7/15 Potable 10 1400 0.5
Feed Water Parameters
* Based on regular sanitization and proper maintenance of the system
Pressure w/out booster pump (psi)
Temperature Pressure w/booster pump(psi)
1–35˚ C 90 max/60 min. 30 max/flooded suction min.
ParticulatesPOU Filter (optional)
>0.2 µm
GlasswareWashing/Rinsing
Reagent Preparation
Buffer Preparation
General Chemistry
Qualitative Analyses
Feed to EnvironmentalCabinets
PURELABOption-Q 7/15
Application
* Fouling Index
l
llll
l
CarbonDioxide (ppm)
30
Flow RateLPH@25˚C
7/15
115
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB®
Option-Q Water Purifiers
Consumables and Accessories
Pretreatment Cartridge
Reverse Osmosis Cartridge Module
Ion Exchange Cartridge Pack
UV Lamp
Point of Use Filter
Chlorine Sanitization Tablets
Composite Vent Filter
Pretreatment Filter
LC140
LC143
LC163
LC118
LC145
CT1
LC136M2
LC123
Consumables
Storage Reservoirs - Required with system
25 Liter Reservoir
40 Liter Reservoir
75 Liter Reservoir
DV 25 Liter Docking Vessel
DV 25 Liter Mounting Bracket
Composite Vent Filter
Wall Mounting Kit (25/40 Liter Reservoir)
Wall Mounting Kit (75 Liter Reservoir)
LA611
LA612
LA613
LA621
LA591USA
LC136M2
LA591USA
LA592USA
Option-Q 7/15
PURELAB® OPTION-Q SYSTEMORDERING INFORMATION
Reservoir is required with Option-Q unit (sold separately)All units come complete with installation kit and full set of cartridges
MODEL Catalog Number
PURELAB Option-Q 7
PURELAB Option-Q 7 BP w/booster pump
PURELAB Option-Q 15
PURELAB Option-Q 15 BP w/booster pump
OQ007XXM1
OQ007BPM1
OQ015XXM1
OQ015BPM1
Installation Kit (supplied)
Installation Kit (with saddle valve)
Pressure Regulator Valve (inlet)
Booster Pump Kit
Wall Mounting Kit (PURELAB Option-Q)
Flow Upgrade Kit (7–15l/hr)
RS232 Printer Kit
Remote Dispense Valve
Remote Control Station
Remote Dispensing Gun
Prefilter if Boost Pump Fitted
LA513
LA506
LA512
LA609
LA622USA
LA605
LA618
LA521
LA675
LA629
LA582
Accessories
116
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB® Prima 7/15/20Reverse Osmosis Systems
PURELAB® Prima reverse osmosis water purification systems deliver Type III/IV primary
grade water from a tap feed. All models continuously monitor and display water quality
and operational parameters, ensuring a constant supply of pretreated quality water. Prima
systems are ideal as pretreatment to ultrapure water polishers or for routine glassware
washing.
Standard Features and Benefits
• Advanced high flux TFC membranes
• Easy front loading cartridges
• Cartridge change indicator
• Microprocessor controlled system management with continuous water quality
monitoring through unique GRID display
• Data collection capabilities through RS232 interface
• Adjustable audio-visual alarms
• Upgradable to higher flow rates
• Wall or bench mountable
• Supplied complete with all consumables
PURELAB® PRIMA 7/15/20 SYSTEM SPECIFICATIONS
Performance Specifications
MODEL Inorganics Flow Rate LPH @ 25˚ C
TOC(ppm)
Bacteria*CFU/ml
Organics
PURELAB Prima 7/15/20 Up to 98% rejection(90% min)
7 or 15 or 20<0.1 <5 >99% rejection
MODEL HxWxD (in) Weight (lbs) Power Requirements
PURELAB Prima 7/15/20 18.2x16.2x8.3 Prima 7–25.4Prima 15–27.6Prima 20–28.7
110–240 V 50- 60 Hz
System Dimensions
MODEL Feedwater MaximumFI*
Max.Conductivity
µS/cm
Max. FreeChlorine (ppm)
PURELAB Prima 7/15/20 Potable 10 1400 <0.5
Feed Water Parameters
* Based on regular sanitization and proper maintenance of the system
Pressure w/out booster pump
(psi)Temperature
Pressurew/boosterpump (psi)
1–35˚ C 90 max/60 min 30 max/flooded suction
Particulates
>99% removal
Glassware Washing
Hydroponics
Pretreatment to Ultrapure water systems
PURELABPrima 7
Application PURELABPrima 20
PURELABPrima 15
lll
lll
lll
*Fouling Index
117
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB® Prima 7/15/20Reverse Osmosis Systems
Consumables and Accessories
Pretreatment Cartridge
RO Module (7.5 lph)
Wall Mounting Bracket
Chlorine Sanitization Tablets
Flow Upgrade Kit (7–15 lph)
Flow Upgrade Kit (15–20 lph)
Flow Upgrade Kit (7–20 lph)
RS232 Printer Kit
Pressure Regulator
Raw Water Booster Pump Kit
Remote Control Station
Installation Kit (supplied)
LC140
LC143
LA622USA
CT1
LA614
LA615
LA616
LA618
LA512
LA609
LA628
LA513
Storage Reservoirs - Required with system
25 Liter Reservoir
40 Liter Reservoir
75 Liter Reservoir
DV 35 Docking Vessel
DV 35 Mounting Bracket
Composite Vent Filter
Wall Mounting Kit (25/40 Liter Reservoir)
Wall Mounting Kit (75 Liter Reservoir)
LA611
LA612
LA613
LA620
LA591USA
LC136M2
LA591USA
LA592USA
PURELAB® PRIMA 7/15/20 SYSTEMSORDERING INFORMATION
All units include installation kit and full set of cartridges
MODEL Catalog Number
PURELAB Prima 7
PURELAB Prima 7 w/booster pump
PURELAB Prima 15
PURELAB Prima 15 w/booster pump
PURELAB Prima 20
PURELAB Prima 20 w/booster pump
PR007XXM1
PR007BPM1 (for feed waters less than 60 psi)
PR015XXM1
PR015BPM1 (for feed waters less than 60 psi)
PR020XXM1
PR020BPM1(for feed waters less than 60 psi)
118
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB® Prima 30/60/90/120Reverse Osmosis SystemsDesigned to meet your higher water volume requirements, PURELAB® Prima reverse
osmosis water purification systems provide primary grade water from a tap feed at flow
rates up to 120 liters per hour. With a built-in integral booster pump, PURELAB® Prima
reverse osmosis systems are ideal as pretreatment to feeding autoclaves, dishwashers or
for use in environmental cabinets.
Standard Features and Benefits
• Auto rinse capability
• Wall or bench mountable
• Low energy consumption
• Microprocessor based management system
• Integral pretreatment
• Performance indicators
• Upgradable to higher flow rates
• Supplied complete with all consumables
PURELAB® PRIMA 30/60/90/120SYSTEM SPECIFICATIONS
Performance Specifications
MODEL Inorganics Flow RateLPH @ 15˚ C TOC (ppm) Bacteria*
CFU/mlOrganics
PURELAB Prima 30/60/90/120
Up to 98% rejection(90% minimum)
30/60/90 or 120<0.1 <5 >99% rejection
MODEL HxWxD (in) Weight (lbs) Power Requirements
PURELAB Prima30/60/90/120
29.2x22.5x12.6 Prima 30–101.4 Prima 60–103.6Prima 90–105.8Prima 120–119.0
110–120 V 60 Hz
System Dimensions
MODEL Source MaximumFI*
Max.Conductivity
µS/cmMax. Free
Chlorine (ppm)
PURELAB Prima 30/60/90/120 Potable 10 1400 <0.5
Feed Water Parameters
* Based on regular sanitization and proper maintenance of the system.
Temperature Inlet Pressure(psi)
1–35˚ C 90 max/20 minimum
Particulates
>99% removal
Glassware Washing
Feed to Autoclaves
PURELAB Prima 30
Application
Steam Generator Feed
Pretreatment to Polishers
PURELAB Prima 90
PURELAB Prima 60
PURELAB Prima 120
Feed to EnvironmentalCabinets
lllll
*Fouling Index
lllll
lllll
lllll
119
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
PURELAB® Prima 30/60/90/120Reverse Osmosis Systems
Consumables and Accessories
5 µm Carbon Filter
RO Module (30 lph)
RO Module (60 lph)
RO Module (90 lph)
Wall Mounting Bracket
Cleaning Solution Elgalite RF
Flow Upgrade Kit (30 to 60 lph)
Flow Upgrade Kit (60 to 90 lph)
Flow Upgrade Kit (90 to 120 lph)
LC123
LC115
LC119
LC120
LA593USA
SOLU30966
LA558
LA559
LA560
Storage Reservoirs - Required with system
40 Liter Reservoir
75 Liter Reservoir
Composite Vent Filter
Wall Mounting Kit (40 Liter reservoir)
Wall Mounting Kit (75 Liter reservoir)
Installation Kit (supplied)
LA587
LA590
LC136M2
LA591USA
LA592USA
LA545
PURELAB® PRIMA 30/60/90/120 SYSTEMSORDERING INFORMATION
All units include installation kit and full set of cartridges
MODEL Catalog Number
PURELAB Prima 30
PURELAB Prima 60
PURELAB Prima 90
PURELAB Prima 120
PRI030XXXX11503
PRI060XXXX11503
PRI090XXXX11503
PRI120XXXX11503
120
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
CENTRA® Packaged Central LaboratoryWater SystemsThe Centra® Lab Central Water System combines purification, storage and distribution in a
single cabinet. The compact system design incorporates, RO, UV, filters, pump and reservoir
in one unit. Purified water is distributed via a loop to multiple labs and points of use in a
building.
Standard Features and Benefits
• Flow rates of 5 gpm and 10 gpm
• Consumable change reminders
• Feeds multiple floors, faucets, polishers, glassware washers, autoclaves and sterilizers
in a facility
• Water leak detection to prevent lab flooding
• Compact design for space utilization
• Easy connection to Building Management System (BMS)
• Validatable
CENTRA® SYSTEM SPECIFICATIONS
Performance Specifications
MODEL Inorganics TOC Bacteria* Particulates
CENTRA MDS
CENTRA LDS
CENTRA LDS-HF
CENTRA RDS
CENTRA RDS-HF
CENTRA S-200
CENTRA S-200-HF
CENTRA R-200
CENTRA R-200-HF
As per feed
As per feed
As per feed
From feed quality up to 18.2 MΩ-cm*
From feed quality up to 18.2 MΩ-cm*
RO Permeate
RO Permeate
Up to 18.2 MΩ-cm*
Up to 18.2 MΩ-cm*
As per feed
As per feed
As per feed
From feed quality to <10 ppb*
From feed quality to <10 ppb*
Typically <100 ppb***
Typically <100 ppb***
<10 ppb2
<10 ppb2
As per feed
As per feed
As per feed
<5 CFU/ml**
<5 CFU/ml**
<50 CFU/ml**
<50 CFU/ml**
<5 CFU/ml**
<5 CFU/ml**
As per feed
As per feed
n/a
0.2µm filter
0.2µm filter
0.2µm filter
<10 micron
0.2µm filter
<10 micron
MODEL HxWxD (in) Weight (lbs) Empty
CENTRA MDS
CENTRA LDS
CENTRA LDS-HF
CENTRA RDS
CENTRA RDS-HF
CENTRA S-200
CENTRA S-200-HF
CENTRA R-200
CENTRA R-200-HF
47x28.75x35
71.7x28.75x35
71.7x28.75x35
71.7x28.75x35
71.7x28.75x35
71.7x28.75x35
71.7x28.75x35
71.7x28.75x35
71.7x28.75x35
254
396
396
396
396
507
507
507
507
System Specifications
MODEL
CENTRA MDS
CENTRA LDS
CENTRA LDS-HF
CENTRA RDS
CENTRA RDS-HF
CENTRA S-200
CENTRA S-200-HF
CENTRA R-200
CENTRA R-200-HF
Feed Water Parameters
SourceMaximum
FI*Conductivity
µS/cm Max. Free Chlorine (ppm)
Potable
Potable
Potable
Potable
Potable
Potable
Potable
Potable
Potable
n/a
n/a
n/a
n/a
5
5
5
5
5
n/a
n/a
n/a
n/a
n/a
1000
1000
1000
1000
n/a
n/a
n/a
n/a
n/a
0.1 ppm
0.1ppm
0.1 ppm
0.1ppm
PressureTemperature
5–35˚ C (41-95˚ F)
5–35˚ C (41-95˚ F)
5–35˚ C (41-95˚ F)
5–35˚ C (41-95˚ F)
5–35˚ C (41-95˚ F)
5–35˚ C (41-95˚ F)
5–35˚ C (41-95˚ F)
5–35˚ C (41-95˚ F)
5–35˚ C (41-95˚ F)
145 psi max
145 psi max
145 psi max
145 psi max
145 psi max
58 psi max
58 psi max
58 psi max
58 psi max
Weight (lbs) working
352
1124
1124
1124
1124
1279
1279
1279
1279
Reservoir VolumeTypical Loop FlowRate****
Up to 18 L/min @ 3 Bar (45psi)
Up to 18 L/min @ 3 Bar (45psi)
38L/min @ 3 Bar (45psi)
Up to 18 L/min @ 3 Bar (45psi)
38L/min @ 3 Bar (45psi)
Up to 18 L/min @ 3 Bar (45psi)
38L/min @ 3 Bar (45psi)
Up to 18 L/min @ 3 Bar (45psi)
38L/min @ 3 Bar (45psi)
200 Liters (53 US gallons)
350 Liters (92 US gallons)
350 Liters (92 US gallons)
350 Liters (92 US gallons)
350 Liters (92 US gallons)
350 Liters (92 US gallons)
350 Liters (92 US gallons)
350 Liters (92 US gallons)
350 Liters (92 US gallons)
Electrical Requirements115V and 11F230V110V / 60Hz
110V / 60Hz
208-230V / 60Hz
110V / 60Hz
208-230V / 60Hz
110V / 60Hz
208-230V / 60Hz
110V / 60Hz
208-230V / 60Hz
*Subject to suitable deionization cylinder. **Subject to correct operating and maintenance procedures. ***Subject to feed water. ****Subject to distribution loop design.
121
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
CENTRA® Packaged Central LaboratoryWater Systems
Consumables and Accessories
CENTRA® Lab Water System
Composite Vent Filter LC156
Bacteriological Filter (0.2 µm) LC157
UV Lamp LC158
Pretreatment Filter (10 µm) LC159
0.2 µm Filter 10” FCWNF1052
RO Module LC161
Dot Matrix Printer Kit LA666
CENTRA Remote Display LA665
High Recovery Reverse Osmosis Kit
(S200 R200) LA679
CENTRA® LAB WATER SYSTEMORDERING INFORMATION
MODEL Catalog Number
CENTRA MDS
CENTRA LDS
CENTRA LDS High Flow
CENTRA RDS
CENTRA RDS High Flow
CENTRA S200
CENTRA S200 High Flow
CENTRA R200
CENTRA R200 High Flow
CNXXXMDM1115
CNXXXLDM1115
CNHFLDM1-230
CNXXXRDM1115
CNHFRRDM1-230
CN200SDM1115
CNHFRS201-230
CN200RDM1115
CNHFRR2M1-230
CENTRA® High Flow System
Composite Vent Filter LC156
UV Lamp LC158
Pretreatment Filter (10 µm) LC159
0.2 µm Filter 20” FCWNF2052
RO Module LC161
Dot Matrix Printer Kit LA666
CENTRA Remote Display LA665
Loop Booster Pump Module LA696
High Recovery Reverse Osmosis Kit
(S200 R200) LA679
Temperature Control Kit LA688
122
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
MEDICA® 7/15 Water Systems (Models S/R/D)for Clinical Analyzers
l l
Compact system utilizing pretreatment, RO, deionization, UV photo oxidation and
in-line microfiltration technologies to produce CLSI (Clinical Laboratory Standards Institute) Type
I water to feed chemistry and immuno-diagnostic analyzers. Available in recirculating model
- MEDICA® R, degassing model - MEDICA® D or standard MEDICA® Systems.
Standard Features and Benefits
• 1 to 15 Megohm purity water
• Flow rates from 7 lph to 15 lph
• Easy front loading cartridges
• Microprocessor controlled system management with continuous water quality
monitoring through unique LCD display
• Adjustable audio-visual alarms and cartridge change indicator
• RS232 port for water quality data collection for compliance with GLP
• Models available with a degassing feature (MEDICA® D 7/15)
• Recirculating models available to ensure consistent purity
• System includes all cartridges
MEDICA® S/R/D 7/15 SYSTEM SPECIFICATIONS
Performance Specifications
MODEL ResistivityMΩ-cm @ 25 C
Flow RateLPH @ 15˚ C
TOC (ppb) Bacteria*CFU/ml
pH Particulates
MEDICA S 7/15
MEDICA R 7/15
MEDICA D 7/15
1–15
1–15
1–15
7/15
7/15
7/15
<30
<30
<30
<1
<1
<1
Neutral
Neutral
Neutral
<0.2 µm
<0.2 µm
<0.2 µm
MODEL HxWxD (in) Weight (lbs) Power Requirements
MEDICA S 7/15
MEDICA R 7/15
MEDICA D 7/15
18.2x21.6x10.6
18.2x21.6x10.6
18.2x21.6x10.6
MEDICA 7–40.8MEDICA 15–41.9
MEDICA 7–40.8MEDICA 15–41.9
MEDICA 7–40.8MEDICA 15–41.9
100–240 V 50-60 Hz
100–240 V 50-60 Hz
100–240 V 50-60 Hz
System Dimensions
MODEL
MEDICA S 7/15
MEDICA R 7/15
MEDICA D 7/15
Feed Water Parameters
* Based on regular sanitization and proper maintenance of the system
SourceMaximum
FI*Conductivity
µS/cm Max. Free Chlorine (ppm)
Potable
Potable
Potable
10
10
10
1400
1400
1400
<0.5
<0.5
<0.5
Pressure w/out booster pump (psi)Temperature Pressure w/booster
pump (psi)1–35˚ C
1–35˚ C
1–35˚ C
90 max/60 min.
90 max/60 min.
90 max/60 min.
30 max/flooded suction
30 max/flooded suction
30 max/flooded suction
Feed Water forClinical Analyzers
MEDICA7
Application MEDICA15
* Fouling Index
123
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
MEDICA® Water Systems for Clinical Analyzers
Consumables and Accessories
Pretreatment Cartridge
RO Module (7.5 lph)
Purification Cartridge
In-Line 0.2 µm Filter
UV Lamp
Wall Mounting Bracket
Chlorine Sanitization Tablets
Pressure Regulator Valve
Booster Pump Kit
Flow Upgrade Kit (7 to 15 lph)
RS232 Printer Kit
Remote Control Station
Installation Kit (supplied)
MEDICA D Degas Membrane
LC140
LC143
LC141
LC125
LC105
LA622USA
CT1
LA512
LA609
LA606
LA618
LA627 (7/15 units only)
LA513
MEMB37275
Storage Reservoirs - One Required with System
25 Liter Reservoir
40 Liter Reservoir
75 Liter Reservoir
DV 25 Liter Docking Vessel
Composite Vent Filter
Wall Mounting Kit (25/40 Liter Reservoir)
Wall Mounting Kit (75 Liter Reservoir)
DV25 Mounting Bracket
LA611
LA612
LA613
LA621
LC136M2
LA591USA
LA592USA
LA591USA
MEDICA® S/R/D 7/15 SYSTEMS ORDERING INFORMATION
All units include installation kit and full set of cartridgesNote: Some MEDICA D systems come with DV-25 Docking Vessel Reservoir. Please note above specifications.
MODEL Catalog Number
MEDICA S 7
MEDICA S 7 w/booster pump
MEDICA D 7 w/booster pump
MEDICA D 7
MEDICA D 7 w/booster pump
MEDICA R 7
MEDICA R 7 w/booster pump
MEDICA S 15
MEDICA S 15 w/booster pump
MEDICA D 15
MEDICA D 15 w/booster pump
MEDICA D 15 w/booster pump
MEDICA R 15
MEDICA R 15 w/booster pump
ME007XXM1
ME007BPM1 (for feed waters of less than 60 psi)
MD007BPM2
MD007XXM1 w/DV-25
MD007BPM1 w/DV-25
MR007XXM1
MR007BPM1
ME015XXM1
ME015BPM1 (for feed waters of less than 60 psi)
MD015XXM1 w/DV-25
MD015BPM1 w/DV-25
MD015BPM2
MR015XXM1 (for feed waters of less than 60 psi)
MR015BPM1
124
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
MEDICA® Pro 30/60/120 Water Systems(S/R/RE) for Clinical Analyzers
The MEDICA® Pro line of water purification systems is available in four models to
meet CLSI Type I water standards for clinical analyzers. The system incorporates an
integral 50 liter storage reservoir, RO, DI purification, UV photo-oxidation and ultra-
microfiltration technologies.
Standard Features and Benefits
• Xport USB device for easy download of system performance data to comply
with GLP guidelines
• Unique space saving design
• Upgradable for higher flowrates
• High capacity Protek deionization cartridges
• Special E-cartridge to reduce CO2 and prolong the life of the DI packs
• Leak detection with auto shut down - minimizing the risk of flooding
• Emergency by-pass loop provides an uninterrupted supply of pure water in an
emergency
MEDICA® PRO S/R/RE SYSTEM SPECIFICATIONS
Performance Specifications
MODEL Inorganics MΩ-cm @ 25 C (77 F)
TOC (ppb) Bacteria*CFU/ml
pHParticulatesµm
MEDICA® Pro S/R/RE >10 <30 <1 Neutral<0.05 µm
MODEL HxWxD (in) Weight (lbs)
Make-up Flow Rate
MEDICA® Pro S/R/RE 32.3x31.1x18.9 MEDICA Pro-S–260.0MEDICA Pro-R/RE –265.0
30/60/120 liters per hour at 15˚C
System Dimensions
MODEL
MEDICA® Pro S/R/RE
Feed Water Parameters
* Based on regular sanitization and proper maintenance of the system
SourceMaximum
FI*Conductivity
µS/cm Max. Free Chlorine (ppm)
Potable 10 1400 <0.5
PressureTemperature
1–35˚ C 90 max/10 min.
* Fouling Index
Silicappm
<0.05
Dispense Flowsto analyzer
4 l/min
125
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
MEDICA® Pro 30/60/120 Water Systems(S/R/RE) for Clinical Analyzers
Consumables and Accessories
MEDICA® PRO SYSTEMSORDERING INFORMATION
MODEL Catalog Number
MEDICA Pro LPS MPXXXPSM1-115
MEDICA Pro S 30 MP030SBM1-115
MEDICA Pro S 60 MP060SBM1-115
MEDICA Pro S 120 MP120SBM1-115
MEDICA Pro R 30 MP030RBM1-115
MEDICA Pro R 60 MP060RBM1-115
MEDICA Pro R 120 MP120RBM1-115
MEDICA Pro RE 30 MP030REM1-115
MEDICA Pro RE 60 MP060REM1-115
MEDICA Pro RE 120 MP120REM1-115
Model Medica Pro-S Medica Pro-R Medica Pro-RE Medica Pro LPS
Pretreatment √ √ √
Extra Capacity Pretreatment
Optional Optional Optional
Air Gap √ √ √ √
Degassing Optional Optional √ Optional
Reverse Osmosis √ √ √
Integral 50 Liter Reservoir
√ √ √ √
Deionization √ √ √ √
2nd Deionization Cartridge
Optional Optional Optional Optional
UV Photo-oxidation √ √ √ √
Ultra-microfiltration √ √ √ √
Recirculation √ √
The MEDICA® Pro line of systems
UV lamp 254nm (destroy bacteria and help to reduce TOC levels) LC105
Ultra Microfilter 0.05 um LC109
Medpure L1 DI (Deionization) high capacity cartridge LC174
Protek L1 (high capacity adsorption pretreatment cartridge - standard size) LC175
Protek L2 (high capacity adsorption pretreatment cartridge - Large size) LC177
RO (reverse osmosis) cartridge 30 lph High flux reverse osmosis membrane LC179
RO cartridge 60 liter per hour High flux 30 liter per hour reverse osmosis membrane LC180
E-cartridge (Reduce CO2 levels to extend Medpure DI cartridge) LC181
Sanitization tablets (12 pk) CT3
Composite vent filter (maintain bacterial integrity of reservoir) LC136M2
MEDICA Pro - Starter Kit 1 (install kit, Protek L1, Medpure L1, 3 sanitization tablets) LC188
MEDICA Pro - Starter Kit 2 (install kit, Protek L2, Medpure L1, 3 sanitization tablets) LC189
Analyzer Feed pump 115V 60Hz LA632
High Flow Upgrade Kit for 2nd Medpure DI cartridge (includes fittings and 1 Medpure DI cartridge) LA700
E-cartridge Upgrade Kit LA701
Castors (useful for under bench installations also) LA704 USA
Note: Cartridge starter kit must be ordered with MEDICA Systems.
126
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
MEDICA® R-200 Water Purification System for High Volume Clinical AnalyzersIntegrated water purification system designed to provide a purified water supply to high
volume clinical analyzers and laboratories with multiple analyzers. The MEDICA® R-200
System combines storage, purification and distribution in a single cabinet.
Standard Features and Benefits
• Delivers up to 21 lpm of CLSI type II water purity
• Incorporates storage reservoir, UV, 0.2µm filter and RO technologies in one unit
• Leak detection with auto shut-down prevents flooding
• Full validation support documentation available to comply with regulatory
standards
• RS232 interface to record system performance for GLP
• Integrated by-pass loop ensures a constant water supply in an emergency
MEDICA® R-200 SYSTEM SPECIFICATIONS
Performance Specifications
MODEL ResistivityMΩ-cm @ 25 C
TOC (ppb) Bacteria*CFU/ml
pHParticulates
MEDICA R-200 >10 <30 <10 Effectively Neutral<0.2 µm
MODEL HxWxD (in) Operational Weight (lbs)
MEDICA R-200 71.7x28.75x35.0 1190.0
System Dimensions
MODEL
MEDICA R-200
Feed Water Parameters
* Subject to correct operating and maintenance procedures
SourceMaximum
FI*Conductivity µS/cm (max) Free
Chlorine (ppm)
Potable 5 1000 <0.2
Pressure Maximum (psi)Temperature
Pressure Minimum (psi)
5–35˚ C 60 30
* Fouling Index
Silica ppm
<0.05
Make-upFlow Rate
200 liters per hour
Dispense Flowsto analyzer
Up to 21 L/min
127
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS
‘
MEDICA® R-200 Water Purification System for High Volume Clinical Analyzers
Consumables and Accessories
RO Particle Pretreatment Filter
UV Lamp
In-line 0.2 µm Filter
Composite Vent Filter
Sanitization Solution (4 x 1000 ml)
LC159
LC158
LC160
LC156
B10000209
MEDICA® R-200 SYSTEMORDERING INFORMATION
MODEL Catalog Number
MEDICA R-200 (230 volt 50 Hz)
MEDICA R-200 (115 volt 60 Hz)
MR200DSM1-230
MR200DSM1-115
128
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS – DEIONIZATION
‘
Portable Laboratory Deionization Systems
The lab wall-mountable deionization systems produce flow rates of 30 to 90 liters per
hour of high purity water. These systems are a cost effective alternative for small
volumes of deionized water. Built in meter, color change indicators and optional
resistivity meters make it easier to monitor your water quality.
B114 Deionizer
• Disposable cartridge system enables a quick and easy exchange when cartridge is
exhausted
• Battery operated wall mountable system with color coded resistivity meter displays
water quality
Vision 125 & 250 Deionizers
• Color change indicators allow users to monitor when resin exhausts and change
out is required
• Optional dispense gun can be connected to either system
Micromeg Deionizer
• Choice of either disposable or exchangeable deionization cartridge
• Battery operated wall mountable system with color coded resistivity meter displays
water quality
Accessories
Vision 125 & 250 Dispense Gun DSP404
Laboratory Performance Specifications
ModelResistivity
MΩ-cmMax Flow
lph
Max OperatingPressure
psi
Max OperatingTemperature
˚C
B114 1-10 30 10 35
Vision 125 1-10 60 90 35
Vision 250 1-10 60 90 35
Micromeg 1-10 90 50 35
System Dimensions
ModelHeightinches
Widthinches
Depthinches
Weightlbs
B114 15 7 6 5
Vision 125 15 4 4 5.5
Vision 250 26 4 4 9
Micromeg 20 8 9 14.3
B114
Vision 125 and 250
Micromeg
For higher flowrate needs, see Service Deionization Systems, Page 182.
129
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS – DEIONIZATION
Laboratory Disposable Deionization (DI)System
Disposable alternative to SDI tanks. This system is a floor mounted 0.25 cubic footcartridge housing and cartridge combination. It is designed to provide pretreated water toa wide range of water treatment applications. Similar to SDI tanks these disposablecartridges are available in carbon media, mixed bed, cation, and anion resins.
For use in:• General laboratory use• Food or beverage processors• Electronics and chemical industries • Hospitals and Universities• Pretreatment to Ultrapure water systems
Standard Features and Benefits • Produces up to 18 megohm water from a potable source • Max flow: up to 2 gpm (8 lpm)• Easy top-loading cartridge with o-ring seal• Many choices of resin media options• Easy cartridge replacement with minimal spillage• Housing comes tested with 3/4” unions attached• Multiple housings can be arranged in parallel or series to meet the flow required
Specification: (housing) Filter housing: 0.25 cubic feet (7 liters) Housing w/ FDA EPDM o-ring.
3/4“ bottom inlet/outlet
System Performance: Feed water parametersMaximum temp: 100°F (38°C)Pressure range: 100 psig (7 bars)Height: 27.5” (69.9cm)Housing weight: 18lbs (8.1kg)
Specification: (Cartridge) Height: 22 inOperational weight: 14 lbs
Ordering information:Item # LAB025DDIDesc: 1/4 cubic foot Gray PVC housing w/ FDA EPDM O-ring.
Consumables:Description Item #1/4 cu foot mixed bed deionizer cartridge for disposable DI system. LABDDIMB1/4 cu foot cation bed deionizer Cartridge for disposable DI system. LABDDICA1/4 cu foot anion bed deionizer Cartridge for disposable DI system. LABDDIAN
*custom media type cartridges available upon request. Minimum orders apply.
Contact technical support at 800-875-7873 x 5000 to discuss your requirements
130
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS – DEIONIZATION
LDIRS Deionization Recirculating Systems
Siemens Water Technologies LDIRS Series water purification systems deliverup to 4 gpm (15 lpm) of deionized water. The system is available in twomodels.
LDIRS03A compact, wall mountable panel capable of supplying up to 3 gpm (11 lpm)deionized water to a small distribution loop up to 100 linear feet in length
LDIRS04A larger skid mounted system capable of supplying up to 4 gpm (15 lpm) ofdeionized water to a larger distribution loop up to 500 linear feet in length.
NOTE: Flow rates dependent upon size and length of distribution piping loop.
System Standard Features: • Dual Filtration: 1.0 micron pre-filtration and 0.2 micron final filtration• Continuous recirculation through all post treatment components
including UV sterilizer and 0.2 micron final filtration• Bacteria destruct ultraviolet sterilizer (254 nm) • Built-in GFCI protection
System Benefits:• Flow rates up to 4gpm • Easy Installation• Both wall panel and skid mounted system have small footprint to
conserve space (additional space required for SDI components)
System Specifications
System Dimensions
Ordering Information: LDIRS Deionization Recirculation System, 3 gpm per minute max. (11 lpm max.) LDIRS03LDIRS Deionization Recirculation System, 4 gpm per minute max. (15 lpm max.) LDIRS04
Model Flow Rate (max) Feed Water Pressure Feed Water Temp.
LDIRS03 3 gpm (11 gpm)min. 40 psig (2.7 bar)max. 90 psig (6.2 barA)
min. 50˚F (10˚C)max. 90˚ (32˚C)
LDIRS04 4 gpm (15 gpm)min. 40 psig (2.7 bar)max. 90 psig (6.2 barA)
min. 50˚F (10˚C)max. 90˚ (32˚C)
Model Electrical Overall Dimensions (cm) Frame Materials Piping Materials
LDIRS03115VAC grounded receptacle
38 (86) L x 9 (23) D X 40 (102) H White PolyethyleneS-80 PVC and Polyethylene Tube
LDIRS04115VAC grounded receptacle
30 (76) L x 24 (61) D X 65 (165) HPowder Coated Carbon Steel
S-80 PVC
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Bottom:DV 25 for use with these systems only:
PURELAB® Option-R 7/15
MEDICA® 7/15
PURELAB® Option-Q
Top:DV 35 for use with thesesystems only:
All PURELAB® Ultra Models
PURELAB® Prima 7/15/20
PURELAB® Option-S 7/15
PURELAB® Classic
LABORATORY WATER SYSTEMS – DOCKING VESSELS
Modular Docking VesselsDV 25 and DV 35
The new DV 25 and DV 35 docking vessels are state-of-the-art high purity water storage
reservoirs specially designed to accommodate the PURELAB® Ultra, Option, Prima and
MEDICA® water purification systems. The L-shaped docking vessels are designed as a base
for the water purification system, resulting in one integral, compact unit, that eliminates
the need for a separate reservoir and saves valuable bench space.
Standard Features and Benefits
• Smooth internal surfaces with no crevices to harbor bacteria
• Inert polyethylene construction minimizes possibility of contamination of stored
water
• Sloping, self-draining base provides more complete sanitization and quicker rinse-out
time
• Recirculation capability combined with composite vent filter prevents ingress of
airborne bacteria and reduces CO2 levels and volatile organics within the reservoir
• Built-in dispense tap (DV 35 version only)
• Docking station design means no unsightly exposed interconnecting tubing or wiring
• Simple “plug-in” connections allow easy connection to the water purification system
for mistake-free operation
• Reservoir water level indicator
• Wall or bench mountable
TECHNICAL SPECIFICATIONS
Product Codes
MODEL Volume TemperatureRange
Flow Rate (tap dispense)
DV 25 ModularReservoirs
DV 35 Modular Reservoirs
25 Liters
35 Liters
5–40˚ C
5–40˚ C
N/A
2.5 liters/min
MODEL HxWxD (in) Weight (lbs)(kg)-empty
Weight (lbs) (kg)-full
DV 25 Modular Reservoirs
DV 35 Modular Reservoirs
20x21x14
20x21x14
13.2 (6)
15.4 (7)
68.2 (31)
94.4 (42)
Dimensions and Weights
MODEL Inlet Outlet Return
DV 25 Modular Reservoirs
DV 35 Modular Reservoirs
5/16" (8 mm)
5/16" (8 mm)
5/16" (8 mm)
5/16" (8 mm)
5/16" (8 mm)
5/16" (8 mm)
Connections
ORDERING INFORMATION
MODEL Catalog Number
DV 25 ModularReservoirs
DV 35 ModularReservoirs
LA621
LA620
CompositeVent Filter
Wall Bracket InstallationKit
LC136M2
LC136M2
LA591USA
LA591USA
Suppliedw/DV 25Suppliedw/DV 35
DV 35
DV 25
131
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
132
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - WATER RESERVOIRS
Stand AloneStorage Reservoirs
Easy-to-use reservoir specially designed for the storage of purified water. Fully wall-
mountable to save valuable bench space.
Standard Features and Benefits
• Inert polyethylene construction minimizes the risk of organic leachables
• Fully opaque to avoid algal growth
• Integrated 5-level switch control to allow automatic fill-up of reservoir by lab
water system
• Sloping base allows complete drainage of water from reservoir
• Composite vent filter eliminates contamination of water from CO2, volatile
organic compounds or airborne bacteria
• Available in 3 convenient sizes — 25 liter, 40 liter and 75 liter
• Designed for use with PURELAB® systems
RESERVOIR SPECIFICATIONS
MODEL HxWxD (in) Weight (lbs) Useable Volume
25 Liter Reservoir
40 Liter Reservoir
75 Liter Reservoir
16x14x11
21x16x12
27x20x14
11 lbs Empty/ 66 lbs Full
18 lbs Empty/ 106 lbs Full
26 lbs Empty/ 192 lbs Full
25 Liters
40 Liters
75 Liters
ORDERING INFORMATION
MODEL Catalog Number
25 Liter Storage Vessel
40 Liter Storage Vessel
75 Liter Storage Vessel
Reservoir 40 Liter
Reservoir 75 Liter
Composite Vent Filter (supplied)
Wall Mounting Bracket (25/40 Liters)
Wall Mounting Bracket (75 Liters)
For use with MEDICA®, PURELAB® Prima and Option Systems
LA611 (for 7 or 15 lph systems)
LA612 (for 7 or 15 lph systems)
LA613 (for 7 or 15 lph systems)
LA587 (for 30,60 or 120 lph systems)
LA590 (for 30,60 or 120 lph systems)
LC136M2
LA591USA
LA592USA
133
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS – ACCESSORIES
Polypropylene Carboys
Convenient polypropylene carboys for storage of high purity water. Carboys come
with or without spigot for ease of use. Large handles provide easy transportation in
the lab.
• Steam autoclavable at 121˚ C
• Large handles help with pouring and carrying
• Front spigot for easy dispensing
Ordering Information
Part # Description
CARBOYPP2 Carboy 2.5 gal (10L) PP without spigot, autoclavable
CARBOYPP5 Carboy 5 gal (20L) PP without spigot, autoclavable
CARBOYPP2SP Carboy 2.5 gal (10L) PP with spigot, autoclavable
CARBOYPP52SP Carboy 5 gal (20L) PP with spigot, autoclavable
134
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS – ACCESSORIES
Polypropylene Faucets
Designed for easy dispensing of deionized or distilled water where high purity is
required. Reduces the risk of bacteria.
• Laboratory faucets are available in countertop and wall mounted style
• Available with integral vacuum breakers
• Recirculating faucet available
• Made from pure unpigmented polypropylene
Ordering Information
Part # Description
LFSPRF1PP Polypro recirculating faucet, deck mount gooseneck
LFSPF10VB Polypro deck mount lab faucet with integral vacuum breaker (welded assembly)
LFSPF30VB Polypro deck mount lab faucet with integral vacuum breaker (threaded assembly)
LFSPF20VB Polypro wall mount lab faucet with integral vacuum breaker (welded assembly)
LFSPF40VB Polypro wall mount lab faucet with integral vacuum breaker (threaded assembly)
LFSPF10STD Polypro faucet, gooseneck deck mount (welded assembly)
LFSPF20STD Polypro faucet, gooseneck wall mount (welded assembly)
LFSPF30STD Polypro faucet, gooseneck deck mount (threaded assembly)
LFSPF40STD Polypro faucet, gooseneck wall mount (threaded assembly)
135
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS – ACCESSORIES
TOTAL-CHECK™ 900
TOC (Total Organic Carbon) Monitor
The Total-Check™ 900 TOC monitor provides a total picture of water quality. Thisstand alone unit can be used with any lab water purification system to continuallymeasure the levels of organic substances in high purity water at the systems’dispense. Total-Check™ 900 offers quick, accurate, easy to read measurements ofwater quality being produced.
• 1-999 ppb TOC levels• Calibration services available • Easy to read, single LCD screen• Dual wavelength 185/254nm UV lamp
PERFORMANCEOperating Range: 1-999 ppb TOCDisplay Resolution: single ppb incrementsRepeatability: +/-5%Accuracy: +/-15% or +/- 1 ppb (whichever is greater)
WATER SAMPLE:Inlet Pressure: 70 psi MAX (4.8 bar) Temperature: 5 to 35ºC (41-95ºF)Resistivity: 15MΩ-cm@25ºC ** May also be use with sample resistivity between 5 and 15MΩ-cm@25ºC, repeatability and
accuracy levels will be lower.
SPECIFICATIONS:Operating Temperature: 15 to 30ºCOperating Weight: 4.2lbs (1.9kg) Height: 9.3 inches (237 mm) Width: 6.1 inches (155 mm)Depth: 5.9 inches (150 mm) Electrical: 100-230V /50-60Hz
ORDERING INFORMATION:US Model TM900M001UE Model TM900ME01
CONSUMABLES / ACCESSORIES: Replacement UV Lamp: TM900M001 Inlet / Outlet tubing: TMFTPF04949Tube Tubing 25’: TMFTPF04945 Luer Fittings (5 pk): TMFTPF04950
136
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS – ACCESSORIES
Remote Control Stations
Remote user interface for the PURELAB® Prima, PURELAB® Option and MEDICA® waterpurification systems. Easy to use, mountable unit fully replicates the GRID (graphically intuitive display) panel providing constant water system monitoring capabilitiesfrom a remote location.
• Replicates GRID display monitor on water purification system• Easy to read display with icons and graphical representation of the process flow• Audio visual alarms to alert user when consumables need replacing or when
reservoir water level is low• Provides parallel display capabilities to simultaneously display system parameters
from 2 different locations• RS232 port for connection to a printer for easy data collection of water quality
and system performance for compliance with GLP guidelines• Compact size fits in any location• Wall, bench, panel, or furniture mountable offers flexibility and convenience
STANDARD FEATURES AND BENEFITS
REMOTE CONTROL STATION SPECIFICATIONS
Weight (lbs) H x W x D Temperature Maximum Distance from Water System (Ft)
2.2 4.75 x 7.90 x 2.75 5˚ C–40˚ C 24.6
Ordering Information
MODEL Catalog Number
PURELAB Prima 7/15/20 RES
PURELAB Option-S 7/15 RES
PURELAB Option-R 7/15 RES
MEDICA 7/15 RES
LA628
LA624
LA625
LA627
137
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS – ACCESSORIES
Remote Dispense Gun
Premium dispense gun allows dispensing of purified water from a remotelocation. Ergonomic design and push and lock dispense mechanism providescomfort and drop-by-drop control of purified water while filling laboratorycontainers.
• Ability to dispense up to 6 1/2 feet from the water purification system at a flowrate up to 1.5 lpm
• Can be operated with optional point of use filter• Integral recirculation capability up to point of dispense when used with a water
system with recirculation pump• Drop-by-drop dispense control for greater dispensing accuracy• Push back and lock dispense mechanism allows hands-free operation• Wall mountable
STANDARD FEATURES AND BENEFITS
Ordering Information
MODEL Catalog Number
Remote Dispense Gun
Remote Dispense Gun
LA629 For use with PURELAB® Option R 7/15
LA644 For use with PURELAB® Ultra and PURELAB® Classic
REMOTE DISPENSE GUN SPECIFICATIONS
Tube Length Flow Rate(Depending on water system used)
Approx 6'.5" 0.8–1.5 lpm
138
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
CARTRIDGE SPECIFICATIONS
Dimensions 500 1000
LABORATORY WATER SYSTEMS - FILTRATION SYSTEMS
Point-of-Use High Purity WaterCapsule Filters
Designed to provide absolute filtration at point of dispense on laboratory ultrapure
water systems or after standard service deionization systems. Disposable design makes
filtration easy and convenient.
Standard Features and Benefits
• Available in 0.1 µm or 0.2 µm pore size ratings
• Two convenient sizes — 500 cm2 and 1000 cm2 effective filtration area
• Hydrophilic polyethersulfone bacterial retentive membrane–based on
Brevundimonas diminuta challenge (HIMA)
• Integrity tested and validated, making them ideal for pharmaceutical and
microelectronics applications
• Low extractable welded housing and materials—no adhesives or glues
• Non-pyrogenic per USP and LAL testing
Capsule Filters
0.2 µm 1/4" NPTM x 1/4" Hose Barb
Half size 0.1 µm 1/4" NPTM x 1/4" Hose Barb
Half size 0.2 µm 1/4" NPTM x 1/4" Hose Barb
Half size 0.1 µm 1/4" NPTM x 1/4" NPTM
Half size 0.2 µm 1/4" NPTM x 1/4" NPTM
Half size 0.1 µm 1/4" NPTM x 1/4" Hose Barb w/filling bell
Half size 0.2 µm 1/4" NPTM x 1/4" Hose Barb w/filling bell
Full size 0.1 µm 1/4" NPTM x 1/4" Hose Barb
Full size 0.2 µm 1/4" NPTM x 1/4" Hose Barb
Full size 0.1 µm 1/4" NPTM x 1/4" NPTM
Full size 0.2 µm 1/4" NPTM x 1/4" NPTM
Full size 0.1 µm 1/2" NPTM x 1/2" NPTM
Full size 0.2 µm 1/2" NPTM x 1/2" NPTM
CW3750
FCCFH11S1
FCCFH11S2
FCCFH12S1
FCCFH12S2
FCCFH14S1
FCCFH14S2
FCCFP11S1
FCCFP11S2
FCCFP12S1
FCCFP12S2
FCCFP23S1
FCCFP23S2
Filtration Area
Diameter (OD)
Length/in (cm)
Materials
Cartridge
Media
Operating Parameters
Maximum Temperature
Max. Oper. Pressure
Max. Momentary Pressure
Filtration Rating
Toxicity
Validation
Recommended Water Flow Rates –gpm (lpm)
0.1 µm
0.2 µm
Integrity Test - Pore Size (MinimumWater Bubble Point)
0.1 µm
0.2 µm
Sanitizing Agents
500 cm2
2.7" (6.8 cm)
4.8" (12.2)
Polypropylene caps, core and cage
Pleated polyethersulfone
140° F (60° C) @ 30 psid (2.1 bar)
60 psid (4.1 bar) @ 20 C
100 psid (7.0 bar) @ 20 C
100% Absolute
Non-toxic by USP Class VI Biological test for plastics
HIMABacterial challenge test methods (107 organisms/cm2)
0.04 (0.16)/1 psid
0.1 (0.38)/1 psid
≥ 90 psig (≥ 6.2 bar)
≥ 45 psig (≥ 3.1 bar)
Hydrogen peroxide or autoclaved for 20 minutes at 121 C
1000 cm2
2.7" (6.8 cm)
6.7" (16.9)
Polypropylene caps, core and cage
Pleated polyethersulfone
140° F (60 C) @ 30 psid (2.1 bar)
60 psid (4.1 bar) @ 20 C
100 psid (7.0 bar) @ 20 C
100% Absolute
Non-toxic by USP Class VI Biological test for plastics
HIMA Bacterial challenge test methods (107 organisms/cm2)
0.1 (0.38)/1 psid
0.3 (0.38)/1 psid
≥ 90 psig (≥ 6.2 bar)
≥ 45 psig (≥ 3.1 bar)
Hydrogen peroxide or autoclaved for 20 minutes at 121˚ C
139
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Convenient, economical, high quality modular water filtration system that operates
on city water pressure and can easily be expanded to fit most needs. No electricity
required. Up to 18 Megohm water quality can be achieved with this system.
Standard Features and Benefits
• Consistent source of high quality water at 50% the cost of distilled water
• Removes organics, phosphates, chlorine, and essentially all ionizable
constituents from water supply
• Convenient color change resin to indicate resin exhaustion
• Quick and easy installation
• No instruments needed
• Water quality up to 18 megohm-cm resistivity can be achieved
• Flexible system configuration to meet specific needs
SPECIFICATIONS
Cartridge Flow Rate GPH Capacity(grains as CaCO3) Dimensions Shipping Weight Maximum Operating
Pressure (psi)
Adsorber
Metex
Universal
Research
7.2
7.2
7.2
7.2
NA
3200
1600
1000
3 1/2"x19 3/4"
3 1/2"x19 3/4"
3 1/2"x19 3/4"
3 1/2"x19 3/4"
6 lbs single/36 lbs six pack
6 lbs single/36 lbs six pack
6 lbs single/36 lbs six pack
6 lbs single/36 lbs six pack
30
30
30
30
Cartridge Removal
Adsorber
Metex
Universal
Research
For pretreatment of water containing organics, free chlorine, phosphate complexes, and turbidity.
For removal of all metallic ions to a level of 1% of the influent concentration. Removes ammonia and other cations from condensate samples.
Reduces ion concentration to a level obtainable by single distillation. All ionizable constituents are removed except free carbon dioxide and silica.
Reduces ion concentration to a level obtainable by triple distillation.Essentially all ionizable constituents including silica and free carbon dioxide are removed.
ORDERING INFORMATION
Absorber Cartridge single pack
Absorber Cartridge six pack
Metex Cartridge single pack
Metex Cartridge six pack
Universal Cartridge single pack
Universal Cartridge six pack
Research Cartridge single pack
Research Cartridge six pack
Single assembly bracket single pack
Single assembly bracket six pack
Single assembly bracket with faucet adapter single pack
Single assembly bracket with faucet adapter six pack
Duplex assembly Bracket single pack
Duplex assembly Bracket six pack
Duplex assembly Bracket with faucet adapter single pack
Duplex assembly Bracket with faucet adapter six pack
3C0200002
3C0200003
3C0400002
3C0400003
3C0600002
3C0600003
3C0800002
3C0800003
3C1200003
3C1200004
3C1200007
3C1200008
3C1200011
3C1200012
3C1200015
3C1200016
Applications
Environmental and humidity chambers
Recharging lead and acid batteries for cars, fork lifts, etc
Electronic cleaning equipment (with 99% isopropyl alcohol bath to wash solder
trails and flux off circuit boards)
Steaming devices used in food industry
Photo processing and printing applications
Humidifiers (including computer room humidifiers)
Ice Machines
Hydroponics
LABORATORY WATER SYSTEMS - FILTRATION SYSTEMS
IWT® Cartridge Filtration System
140
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
Replacement Cartridges for LaboratoryWater Purification Systems
Cartridges provide ultra-high-purity water for use with MODULAB®, PURELAB®, Millipore®
and Barnstead® water systems. The wide selection of cartridge styles and types allows
custom-configuration of your laboratory water system to meet a variety of application
needs.
Standard Features and Benefits
• Higher ion exchange capacity than other manufacturers’ cartridges
• Lower cartridge replacement costs
• Unique diffuser design for even distribution of water and maximum cartridge life
• Vacuum packaging for maximum shelf life
• Ultrasonic-welded seams and joints for extractable-free product water
• Date coded for critical quality control
• GMP cartridge manufacturing facility
• Patented downflow design maximizes removal efficiency and cartridge capacity
We offer the following types of resin:
Activated Carbon Used for pretreating tap water before deionization. Removes traces
of chlorine and organics through adsorption.
Colloidal Removal Resin Removes colloids and bacteria by ion exchange and
adsorption. Protects and enhances performance of deionization resin, and extends
final filter life.
Cation Exchange Resin Removes positively charged impurities. When used alone, this
resin will lower solution’s pH. Usually used in conjunction with anion resin in a mixed
bed ion exchange cartridge.
Anion Exchange Resin Removes negatively charged impurities. When used alone, this
resin will raise a solution’s pH.
Oxygen Removal Resin Removes oxygen and prevents corrosion in water cooling loop
applications. For use on feed water containing less than 10 ppm ionized solids.
Mixed Bed Ion Exchange Contains a mixture of cation and anion resins in a mixed bed
to purify water up to 18.2 megohm-cm. Used to polish pretreated water, or to
produce high-purity water in a loop system.
Organic Scavenger/Removal Resin Removes trace organics from deionized water to less
than 10 ppb TOC.
High Capacity Ion Exchange Combines anion and cation resin in a 2-bed configuration.
Used for purifying large quantities of water at a lower purity level than provided by
mixed bed deionization. May also be used to pretreat mixed-bed cartridges for longer
cartridge life.
Custom Cartridges
Specialty resin cartridge configurations are available to meet your needs. Call our
technical service department for more information. Minimum order volumes apply.
141
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
Replacement Cartridges for Siemens WaterTechnologies, USFilter® and ELGA®Laboratory Water Systems
Ultra-microfilter
Point-of-Use Filter
Purification Pack-RO Feed (for MK1 Ultras)
Purification Pack-SDI Feed (for MK1 Ultras)
Purification Pack-Low Ionic (for MK1 Ultras)
Purification Pack-Low TOC (for MK1 Ultras)
Ultrafilter (5,000 MWCO)
Labpure S1 DI cartridge - RO feed
Labpure S2 DI cartridge - SDI feed
Labpure S3 DI cartridge - Low Ionic
Labpure S4 DI cartridge - Low TOC
LC109
LC134
LC147
LC148
LC149
LC150
LC151
LC182
LC183
LC184
LC185
PURELAB® Ultra Water System Cartridges
PURELAB® Classic Water System Cartridges
Purification Cartridge (For MK1 Classic)
Ultra Filter 5000 mwt
Purification Cartridge (For MK1 Classic)
Endoguard 5000 MWCO UF Cartridge (For MK1 Classic)
Final Filter 0.2 µm (1/pk)
Labpure S5 purification cartridge
LC162
LC169
LC126
LC151
LC134
LC186
PURELAB® Prima Water System Cartridges
Pretreatment Cartridge (PURELAB Prima 7/15/20)
Pretreatment 5 Micron Carbon Filter (Prima 30/60/90/120)
RO Module (7.5 liter/hour) — (Prima 7/15/20)
RO Module (30 liter/hour) — (Prima 30)
RO Module (60 liter/hour) — (Prima 60, 120)
RO Module (Prima 90)
LC140
LC123
LC143
LC115
LC119
LC120
PURELAB® UHQ Water System Cartridges
Reverse Osmosis Cartridge
Ultra Microfilter Cartridge 0.05 µm
UHQ Purification Pack (2 Organic Absorption Cartridges and 2 Ion Exchange Cartridges)
Composite Vent Filter
UHQ5
LC109
UHQPACKA
UHQ4
PURELAB® Option Water System Cartridges
Pretreatment Cartridge (Option 7 & 15)
Pretreatment 5 micron Carbon Filter (Option 30 & 60)
Purification Cartridge (Option R&S 7 & 15)
Purification Cartridge (Option-Q 7 & 15)
Purification Cartridge (Option 30 & 100)
RO Module (7.5 liter/hour) — (Option 7 & 15)
RO Module (30 liter/hour) — (Option 30)
RO Module (60 liter/hour) — (Option 60)
Point-of-Use Filter (Option 7 & 15-R)
Point-of-Use Filter (Option 30 & 60-R)
LC140
LC123
LC141
LC163
LC114
LC143
LC115
LC119
LC145
LC106
142
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
Replacement Cartridges for Siemens WaterTechnologies, USFilter® and ELGA®Laboratory Water Systems
MEDICA® Water System Cartridges
Pretreatment Cartridge (Medica 7/15)
5 µm Carbon Filter (Medica 30/100)
Purification Cartridge (Medica 7/15)
Purification Cartridge (Medica 30/100)
RO Module (Medica 7/15)
RO Module (30 lph)
RO Module (60 lph)
RO Module (100 lph)
In-Line 0.2 µm Filter (Medica 7/15)
In-Line 0.05 µm UMF Filter (Medica 30/100)
LC140
LC123
LC141
LC114
LC143
LC115
LC119
LC137
LC125
LC109
MEDICA® Pro Water System Cartridges
0.05µm ultra microfilter LC2109
Medpure L1 DI (Deionization) high capacity cartridge LC174
Protek L1 (high capacity adsorption pretreatment cartridge - standard size) LC175
Protek L2 (high capacity adsorption pretreatment cartridge - Large size) LC177
RO (reverse osmosis) cartridge 30 lph High flux reverse osmosis membrane LC179
RO cartridge 60 lph High flux reverse osmosis membrane LC180
E-cartridge (Reduce CO2 levels to extend Medpure DI cartridge) LC181
Castors (for easy mobility) LA704USA
MEDICA® R-200 Water System Cartridges
RO Pretreatment Filter
In-line 0.2µm Filter
Composite Vent Filter
Bacterial Vent Filter
LC159
LC160
LC156
LC157
CENTRA® Water System Cartridges
Bacterial Filter
Composite Vent Filter
0.2µm Filter
RO Module
Pretreatment Filter
LC157
LC156
LC160
LC161
LC159
MODULAB® High Flow System Cartridges
Carbon Cartridge
Organic Removal Cartridge
0.05µm Micro Ultra Filter
0.2µm Bacteria Filter
MLHF20CAR1
MLHF20OS01
MLUF020S05
MLUF020S2
PURELAB® Plus Water System Cartridges
PURELAB Purification Quadpack w/0.2 µm Final Filter
PURELAB Purification Quadpack
Endoguard 5000 MWCO UF Membrane Cartridge
Final Filter 0.2 µm (1/pk)
PLC6000
PLC5000
LC151
LC134
143
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
Replacement Cartridges for Siemens WaterTechnologies, USFilter® and ELGA®Laboratory Water Systems
MODULAB® Carbon Cartridges
10" Carbon Cartridge (1/pk)
10" Carbon Cartridge (4/pk)
20" Carbon Cartridge (1/pk)
10" Pretreatment Carbon Cartridge/5 µm Prefilter
20" Pretreatment Carbon Cartridge/5 µm Prefilter
DICR1000-1
DICR1000-4
DICR2000-1
LBCPT1002
LBCPT2004
MODULAB® Water System Cartridge Kits
Modulab Cartridge Kit for RO Feed – Contains 1 EA CWCF23110,2EA DIMN1000-1, 1 EA DIOR1000-1, 1 EA CW3750 Final FilterModulab Cartridge Kit for DI Feed – Contains 1 EA DICR1000-1, 2EA DIMN1000-1, 1 EA DIOR1000-1, 1EA CW3750 Final FilterModulab UV/UF Start Up Kit 20" – Contains (1) 20" UFMembrane (40,000 MWCO), (1) 0.1 µm Capsule FilterModulab Clinical Cartridge Kit
LBMPC1006
LBMPC1005
UFSU8202
LBCCK1002
Miscellaneous Laboratory Cartridges
Mixed Bed 10" cartridge PVC P-154
Mixed Bed 10" cartridge
Mixed Bed 10" cartridge with porex disc, 4 pack
Mixed Bed 5" cartridge with porex disc
Anion Cartridge 10"
Anion/Cation separate Bed 5" cartridge
Anion/carbon separate Bed 10" cartridge
DIMNP154
DIMN4000
DIMN1000-4PD
DIMN0500-PD
DIOH4000
DISB0500
DIOH4010
MODULAB® Water System Membrane Cartridges
10" RO Membrane (TFC)
20" RO Membrane (TFC)
10" UF Membrane (10,000 MWCO)
10" UF Membrane (40,000 MWCO)
20" UF Membrane (40,000 MWCO)
DIRO3002
DIRO3222
UFPW3308T
DIUF8102
DIUF8202
MODULAB® Water System Resin Cartridges
10" Mixed Bed Cartridge (1/pk)
20" Mixed Bed Cartridge (1/pk)
10" Organic Cartridge (1/pk)
20" Organic Cartridge (1/pk)
10" Pureone Cartridge (1/pk)
10" Separate Bed DI (1/pk)
20" Separate Bed DI (1/pk)
12" Mixed Bed Cartridges (1/pk)
12" Mixed Bed Cartridges (2/pk)
DIMN1000-1
DIMN2000-1
DIOR1000-1
DIOR2000-1
DIMBS1000
DISB1000-1
DISB2000-1
DIMM1200-1
DIMM1200-2
144
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
LiquiPure® Replacement Cartridges forMillipore® Laboratory Water Systems
LiquiPure® 1 Replacement Cartridges for Milli-Q® and Alpha-Q ™ Laboratory Water Systems
The LiquiPure1 replacement cartridges for Milli-Q and Alpha-Q laboratory water systemsprovide ultra-high-purity water with very low TOC and extractable levels. The cartridgecontains a variety of purification media to remove specific types of feed watercontaminants. All wetted parts are constructed of all-natural polypropylene tominimize extractables, while a unique downflow design ensures optimum removal oforganic and inorganic impurities. A pigmented polypropylene exterior prevents light frompenetrating to minimize microbial growth. Cartridge contains macroreticular activatedcarbon, ultra-high-purity mixed bed ion exchange resin, and an organic scavenger.
LiquiPure® CLC Replacement Cartridges for Millipore AFS® Analyzer Feed Systems
The LiquiPure CLC replacement cartridges for Millipore AFS Analyzer Feed systems provide high-puritywater to feed laboratory clinical chemistry analyzers. The cartridge contains ultra-high-puritymixed bed ion exchange resin to produce NCCLS Type 1 quality water. All wetted parts areconstructed of all natural polypropylene to minimize extractables, while the unique designensures optimum removal of inorganic impurities. A pigmented polypropylene exterior preventslight from penetrating to minimize microbial growth. Cartridge contains ultra-high-purity mixedbed ion exchange resin.
LiquiPure® RO Replacement Cartridges for Millipore Milli-RO® and AFS® Systems
These duplex RO pretreatment cartridges for Millipore Milli-RO and AFS Analyzer Feedsystems includes granular activated carbon for chlorine removal, depth filtration forparticulate removal and a food grade sequestering agent to protect the RO membranefrom fouling and scale formation. Designed in a duplex configuration, the cartridge can berotated and reconnected when one-half has been exhausted. All wetted parts areconstructed of all natural polypropylene to minimize extractables, while thepigmented polypropylene exterior prevents light from penetrating to minimize microbialgrowth. Cartridge contains granular activated carbon, an anti-scaling agent and a prefilter.
ORDERING INFORMATION
LiquiPure 1 Cartridge
LiquiPure 1 Cartridge w/0.2 µm Final Filter
Final Filter 0.2 µm (1/pk)
LP1000
LP2000
LC134
ORDERING INFORMATIONLiquiPure CLC Cartridge
LiquiPure CLC Cartridge
LiquiPure CLC Cartridge
LiquiPure CLC Cartridge
LP3000
LP3000R
LP3000R & LP4000FCCFH11S2
LP3000R FCCFH11S2
CPMQ004R1CPMQ004D2CPMQK05R1CPMQK05D2CPMQK05RE
MPGL04SK2
Millipore Equiv. Part NumberCP4ALLRES
CP4ALLRES
CPKITAFS2
CPAFS04R1
Siemens Catalog Number
ORDERING INFORMATION
LiquiPure RO Cartridge
LiquiPure RO Cartridge
LP4000
LP4000R
Millipore Equiv. Part Number
CPR0P0402
CPR0P0402
SiemensCatalog Number
Millipore Equiv. Part NumberSiemens Catalog Number
145
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
Replacement Cartridges for Millipore®
Laboratory Water Systems
ORDERING INFORMATION
Replacement Cartridges for Milli-Q® and Other Millipore Systems Millipore Equiv. Part Number
High Capacity Carbon (4/pk)
Mixed Bed (2/pk), Exchange Capacity, 540 Grains as CaCO3
Organic Scavenger (1/pk)
UF Membranes, 10k MW (1/pk)
Prefilter 12" 5 µm
1 ea. DICM 1000-1 Carbon, 2 ea. DIMM 1200-2 Ion Exchange
CWCFF 1492 Capsule Final Filter (1ea.)
1 ea. DICM 1000-1 Carbon, 2 ea. DIMM 1200-2 Ion Exchange,
1 ea. DIOM 1200-1 Organic Scavenger, 1 ea. CWCFF1492
1 ea. DICM 1000-1 Carbon, 2 ea. DIMM 1200-2, 1 ea.
CWCFF1492, 1 ea. 10” Polysulfone 0.2 µm Cartridge
1 ea. FCWN12152, DICM 1000-1, DIMM 1200-1, DIOM 1200-
1, CWCFF1492
CDFC01204
CPMB01202
CDEX01201
CDUF01201
CDPRM1206
CFUF01204
CFOF01205
CFIF01205
CFOF012P5
Replacement Cartridge Kits for Millipore Super-Q® Systems Siemens Catalog Number
Activated Carbon (1/pk)
Ion Exchange (>2000 Grain Capacity) (1/pk)
Organic Scavenger (1/pk)
UF Cartridges
0.22 µm Filter 20" (1/pk)
DICM2200-1
DIMM2200-1
DIOM2200-1
CDUF02201
FCDIO20S2
Replacement RO Membranes for Millipore Milli-RO® Plus and AFS® Systems Siemens Catalog Number
TFC RO Membrane
TFC RO Membrane (w/out housing)
TFC RO Membrane (w/out housing)
CA Membrane
TFC RO Membrane
ROGTM3512
LABROKIT
LABROKIT
ROETM3512
60 - CDRC025S1CDRC025S1CDRC025SH
Where Used
3, 4, 5 Bowl Milli-Q or Milli-Q Plus Systems
3, 4, 5 Bowl Milli-Q or Milli-Q Plus Systems
4 & 5 Bowl Milli-Q or Milli-Q Plus Systems
4 & 5 Bowl Milli-Q or Milli-Q Plus Systems
Milli-RO® Systems
4-Bowl Life Science or 3-Bowl Standard
4-Bowl Analytical System
5-Bowl Milli-Q
5-Bowl Milli-Q
Millipore Equiv. Part Number
CDFC02203
CPMB02202
CDEX02201
CDUFM2201
CVDI02TPE
Where Used
4-Bowl Super-Q (Housing #1)
4-Bowl Super-Q (Housing #2 & #3)
4-Bowl Super-Q (Housing #4)
4-Bowl Super-Q (Housing #4 optional)
4-Bowl Super-Q (Housing #4 optional)
Millipore Equiv. Part Number
CDRC012S0
CDRC012HG
CDRCH12HG
CDRO012S0SL2M129V8
60 - CDRC025S1CDRC025S1CDRC025SH
Where Used
Milli-RO 4 & 15
Milli-RO 6-10 and AFS Systems
Milli-RO 30/60/90
Milli-RO 4 & 15
Milli-RO 60/120
Siemens CatalogNumber
120 120
Organex CartridgeIonic CartridgePurification Pack (Elix, RO & Distillation Feed)Purification Pack (DI Feed)Pyroguard 5000 MW Hollow Fiber UF CartridgeVOC CartridgePretreatment FilterPretreatment Filter
DIMOS1201DIMEX1201PPMRO1201PPMDI1201CQUF500DICMVOL01PRCM1201PRCMS001
QTUM00EXQTUM00IXQGARD00R1QGARD00D2CDUFHF05KQTUM000VXPROG00002PROG00001
Milli-Q Academic, Biocel, Synthesis, Element, GradientMilli-Q Academic, Biocel, Synthesis, Element, GradientMilli-Q Academic, Biocel, Synthesis, Element, GradientMilli-Q Academic, Biocel, Synthesis, Element, GradientMilli-Q Biocll, SynthesisMilli-Q Academic, Biocel, Synthesis Element GradientMilli-Q Elix 3,5,10Milli-Q Elix 3,5,10
Replacement Cartridges for Milli-Q® Ultrapure Water Systems Siemens Catalog NumberWhere Used
DICM1000-4
DIMM1200-2
DIOM1200-1
CDUF01201
FCR001205
LBCCM1202
LBRCM1002
LBCCM1202
FCWN010S2
FCWN010S2
DICM1000-1
DIMM1200-1
DIOM1200-1
CWCFF1492
Millipore Equiv. Part Number
146
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
Replacement Cartridge kits for Barnstead®
Laboratory Water Systems
ORDERING INFORMATION
DescriptionSiemens Catalog Number
1 ea. CW0835 Colloid Removal Resin,1 ea. CW0803 High Capacity 2-Bed Resin,2 ea. CW0809 Mixed Bed
1 ea. CW0835 Colloid Removal Resin,2 ea. CW0809 Mixed Bed
1 ea. CW0836 Organic Removal,1 ea. CW0820 Organic Scavenger,1 ea. CW0809 Mixed Bed
1 ea. CW0836 Organic Removal, 1 ea.CW0803 High Capacity 2-Bed Resin,1 ea. CW0809 Mixed Bed, 1 ea. CW0820 Organic Scavenger,
1 ea. CW0835 Colloid Removal Resin,1 ea. CW0803 High Capacity 2-Bed Resin,2 ea. CW5027 Mixed Bed
1 ea. CW0836 Organic Removal,1 ea. CW0803 High Capacity 2-Bed Resin,1 ea. CW5027 Mixed Bed,1 ea. CW5021 Organic Scavenger, Down Flow
1 ea. CW0835 Colloid Removal Resin,1 ea. CW0809 Mixed Bed,2 ea. CW5027 Mixed Bed,2 ea. CW3751 Final Filter
1 ea. CW0836 Colloid Removal,1 ea. CW0809 Mixed Bed,1 ea. CW5021 Organic Scavenger, Down Flow,1 ea. CW5027 Mixed Bed,2 ea. CW3751 Final Filter
1 ea. CW0835 Colloid Removal Resin,1 ea. CW0803 High Capacity 2-Bed Resin,2 ea. CW5027 Mixed Bed
1 ea. CW0835 Colloid Removal Resin,2 ea. CW5027 Mixed Bed
1 ea. CW0836 Organic Removal,1 ea. CW5027 Mixed Bed,1 ea. CW5021 Organic Scavenger, Down Flow
1 ea. CW0836 Organic Removal,1 ea. CW0803 High Capacity 2-Bed Resin,1 ea. CW5027 Mixed Bed,1 ea. CW5021 Organic Scavenger, Down Flow
CW3804
CW3805
CW3806
CW3807
CW4801
CW4802
CW5025
CW5026
CW5028
CW5029
CW5022
CW5023
Replacement Cartridge Kits for NANOpure™ and Other Barnstead Systems
Barnstead replacement cartridges continued on next page
Barnstead Equiv. Part Number
D3804
D3805
D3806
D3807
D4801
D4802
D5025
D5026
D5028
D5029
D5022
D5023
Where Used
NANOpure 4 Module Type I
NANOpure 3 Module Type I
NANOpure 3 Module Type I w/ORGANICfree™
NANOpure 4 Module Type I w/ORGANICfree
Quad Style NANOpure Type I
Quad Style NANOpure Type I w/ORGANICfree
Quad Style NANOpure Type I w/ORGANICfree
Pretreated FeedQuad Style NANOpure Type I w/ORGANICfree
Pretreated Feed
E-pure™ 4 Module Type I
E-pure 3 Module Type I
E-pure 3 Module Type I w/ORGANICfree
E-pure 4 Module Type I w/ORGANICfree
147
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
Replacement Cartridges for Barnstead®
Laboratory Water Systems
ORDERING INFORMATION
Replacement Cartridge Kits for NANOpure™ and Other Barnstead SystemsSiemens
Catalog Number
High Capacity, 2-Bed Ion ExchangeMixed Bed Ion ExchangeOxygen Removal ResinActivated CarbonCation Removal ResinOrganic Scavenger ResinOrganic Scavenger, Down FlowMixed Bed, Organic Removal Colloid, Organic RemovalOrganic Removal Oxygen Removal Mixed Bed, Oxygen Removal, Organic RemovalAnion Removal Mixed Bed, Down Flow
CW0803CW0809*CW0811CW0813CW0815CW0820CW5021CW0832CW0835CW0836CW8809CW8811CW0760CW5027
DescriptionBarnstead Equiv.
Part Number
D0803D0809D0811D0813D0815D0820D5021D0832D0835D0836D8809D8811D0760D5027
Where Used
NANOpure, E-pure™, B-pure™, Cooling LoopsNANOpure, B-pure, Older NANOpure Cooling LoopsB-pure, Cooling LoopsB-pure, Cooling LoopsB-pure, Cooling LoopsNANOpure II, Older NANOpure SystemsQuad Style NANOpure, E-pureB-pure, Still PretreatmentNANOpure, B-pure, E-pureNANOpure, E-pure, Pretreatment for Organic RemovalB-pure, Cooling LoopsB-pure, Cooling LoopsB-pure, Cooling LoopsQuad Style NANOpure, E-pure
Organic Free Cartridge Organic Cartridge Kit DI FeedPretreat Cartridge for Tap & DI FeedUltrapure CartridgeCartridge Kit for RO or Dist. FeedPretreatment DI FeedUltrapure Cartridge0.2µm FilterOrganic Free CartridgePretreatment Cartridge for Dist. or RO FeedUltralow Organics Cartridge for RO or Dist. FeedCartridge Pack Organic Free for DI FeedSanitization CartridgeSanitization Cartridge5µm CartridgeSanitization CartridgeCartridge for RO FeedCartridge Kit for DI Feed
CB50252CB50254CB50251CB50253CB50257CB50230CB50233CB7033X2CB50229CB50231CB50280CB50281CB50223CB50258CB502113CB50245CB50282CB50283
D50252D50254D50251D50253D50257D50230D50233FL703X2D50229D50231D50280D50281D50223D50258D502113D50245D50282D50283
NANOpure Infinity®NANOpure InfinityNANOpure InfinityNANOpure InfinityNANOpure InfinityEASYpure®EASYpureEASYpureEASYpureEASYpureDiamond™DiamondNANOpure®, G-pure, NANOpure Infinity®NANOpure®, G-pure, NANOpure Infinity®Diamond RO, Diamond TIIEASYpureDiamondDiamond
* CW0809 — not for use with Bantam deionizers
Reverse Osmosis MembraneDI CartridgeRemote Dispenser Cross Flow Final Filter Quad StyleReplacement Ultrafilter Element for D4721Ultrapure Ion ExchangeRO MPS CartridgeCarbon FilterDeionizationDeionizationPrefilter, 5µmPretreatment Carbon CartridgeMembrane 15L/hrRO MembraneUF Cartridge
CB2732CW3750CW3751CB4722CB5021CB502114CB502115CB50229CB50245CB9004CB9005CB9006CBFL1265X1CBFL1192Y1
D2732D3750D3751D4722D5021D502114D502115D50229D50245D9004D9005D9006FL1265X1FL1192X1
ULTROpure™ and ROpure™ LPEASYpure II and RF/UVFinal FiltersFinal FiltersNANOpure Quad., E-pureNANOpure Diamond RONANOpure Diamond ROEASYpure SystemsEASYpure II LF and UVROpure InfinityROpure InfinityROpure InfinityNANOpure Diamond RONANOpure Diamond RO
148
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LABORATORY WATER SYSTEMS - REPLACEMENT CARTRIDGES
Replacement Cartridges for Barnstead®
Laboratory Water Systems
Replacement Hose Nipple Cartridge Kits for Barnstead and Other Cartridge Housings
1/2 Size, Mixed Bed Oxygen Removal
High Capacity, 2 Bed
Mixed Bed
Pretreatment
Organic Removal
Mixed Bed (No Dye)
Organic Removal, Mixed Bed
2/3 Size, High Capacity Mixed Bed
Description
Note: Hose Nipple Cartridges are non-pressure applications; outlet must be vented to atmosphere, minimum inletpressure should be 5 psig (0.3 bar) and designed for 3/8" H.B. (9.5mm) connection.
Where Used
180 Grains as CaCO3
1650 Grains as CaCO3
730 Grains as CaCO3
1450 Grains as NaCl to 1 megohm-cm Endpoint
730 Grains as CaCO3
575 Grains as CaCO3
1080 Grains as CaCO3
Siemens Catalog Number
CW8822CW8901CW8902CW8921CW8904CW8911CW8922CW8950
Barnstead Equiv. Part NumberD8822D8901D8902D8921D8904D8911D8922D8950
149
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LEAK DETECTORS
DI-SDI Alert Leak Detector
Specifications
Inlet Power 120V AC – 60 HZ
Power Output 120V, 15 AMP resistive load, and 1/2 HP motor load
Cable Length 12 Feet(Sensor to Alarm Module)
Operational WarningsFor indoor use only!If power to SDI leak detector is interrupted it will not function.If power to SDI leak detector is interrupted and then restored, it will reset.
The DI-SDI Alert is a leak detector and alarm designed to sense deionized water leaks,
initiate an alarm and activate a shut-off valve assembly (not provided).
The device consists of a disk-shaped sensor that rests on the floor near the SDI tank
and a receptacle mounted alarm module with an internal alarm, an external LED
indicator and a 120 VAC grounded power outlet.
In normal operation, the sensor detects no leak and the green LED on the alarm
module remains illuminated and the 120 VAC grounded outlet remains powered.
The alarm condition is initiated when the sensor detects water leakage. The red LED
will be illuminated and the grounded outlet will be de-energized, thus initiating the
feed water shut-off device.
The DI-SDI Alert can be reset by simply shutting off the power to or unplugging the
alarm module.
Features & Benefits
• Provides around-the-clock protection against water damage
• Specially designed to sense small amounts of DI quality water
• Audible alarm, visible LED warning light, reliable power cut-off
• Fully automatic; failsafe operation; no maintenance
150
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LEAK DETECTORS
WLD Model 300A Series Water Leak Detector
SPECIFICATIONSDisplay: Four LED indicator lights: one for power, one for alarm condition and two for relay states.Controls: Four push button switches: alarm silence, alarm reset, calibration, and sensor testInputs: Leak detection sensorOutputs: Alarm relay, DPDT (10 A @ 240 VAC) Control relays (2), DPDT (10 A @ 240 VAC) Horn, 108 dBOperating Temperature: 0-50˚COperating Humidity: 0-95% RH non-condensingPower Supply: 120 VAC, 4.6 VA, 60 Hz via internal transformer. Does not include loads on output relays.Enclosure: NEMA 4XDimensions (Overall): 6.5" x 6.5" x 4.0"
The Model WLD 300A is designed to detect leaks of water or other conductive fluids. The WLD 300A is a cost-effective wayto monitor for leaks on or near commercial water treatment systems, or any location where an undetected leak couldcause damage.
The WLD 300A is designed with a number of unique features not normally found in low-cost water detection systems:
SENSITIVE DETECTION SYSTEM
• Designed with a sensitive detection circuit that allows detection of low conductivity fluids such as high purity water.
• An integral test feature allows the user to periodically test the action of the monitor to ensure proper operation.
OUTPUT FUNCTIONS
• 108 dB alarm horn and LED indicators
• Alarm silence and alarm reset push buttons
SENSOR CALIBRATION
• Two sensors may be connected in series for greater coverage
• May be calibrated for local conditions
REMOTE MONITORING VIA MODEM
• Can be interfaced with other products to provide remote
alarm notification via modem
ELECTRICAL CORD OPTION
• One drop cord (with standard three-prong receptacle) for the
load connected to one of the control relays.
ORDERING INFORMATION
Catalog No. Description
ALWLD300A Leak Alarm w/one sensor
ALWLD300AID Leak Alarm w/one sensor
and one drop cord receptacle
ALWLDAS Alarm sensor
151
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LIGHTS, QUALITY INDICATOR
5-Range Purity Light
This 5-range purity indicator is ideal for monitoring product water quality from DI and
other ultra-pure water purification systems. It offers 5-convenient
resistivity/conductivity ranges and uses a highly visible LED indicator that changes from
green to red when the product water quality falls below the selected cutoff point.
SYSTEM SPECIFICATIONS
MaterialsBody . . . . . . . . . . . . Black NorylCap material. . . . . . Clear ABSSensor pins . . . . . . Gold-plated brass
Power . . . . . . . . . . . . . Power pak source: 115 VACPower pak output: 6 VAC
Display. . . . . . . . . . . . . LED (one red & one green)Power cable. . . . . . . . . 10'Electrical connection . . Spade lugs to screw terminalsAccuracy . . . . . . . . . . . ±10% at 25°CRelative humidity . . . . . to 90%Water temperature. . . . +5°C to 45°CPressure . . . . . . . . . . . 0-150 psi
Resistivity/Conductivity RangesJumper Position Set Point
J1 . . . . . . . . . . . . . . 50K ohms-cm (20 µS/cm)J2 . . . . . . . . . . . . . . 200K ohms-cm (5 µS/cm)J3 . . . . . . . . . . . . . . 500K ohms-cm (2 µS/cm)J4 . . . . . . . . . . . . . . 1 megohm-cm (1 µS/cm)no jumper . . . . . . . . 2 megohm-cm (0.5 µS/cm)
DimensionsHeight . . . . . . . . . . . . . 4.5" ± 0.5" from pins to top of capDiameter . . . . . . . . . . . 1.29" ± 0.25"Fittings . . . . . . . . . . . . . 1/2" and 9/16"
ORDERING INFORMATION
Catalog No. Description
ZWDJ05408* 5-Range Light with transformer
ZWDJ05411* 5-Range Light without transformer
ZWDJ05421* Transformer
ZWDJ05422* Remote 5-Range Light with 8' cord and mounting bracket
ZWDJ05429* Remote 5-Range Light with 50' cord and mounting bracket
ZWDJ05433* Remote 5-Range Light with 100' cord and mounting bracket
*Not for use as final quality indicator in hemodialysis applications
152
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
LIGHTS, QUALITY INDICATOR
Hy-Lite Water Quality Indicator System
Inexpensive water quality indicator system to monitor DI water quality either at the
DI tanks or up to 700 feet away.
Features
• Automatic temperature compensation
• Safe 12 VDC
• Easy 1/2" or 3/4" connections
• Audible alarm option
• Five set points available (25K, 50K, 200K, 1 meg, 2 meg ohm/cm)
• Steady green/flashing red LED display
• Output port for relay and remote alarm modules
ORDERING INFORMATIONCatalog No. Description For Use in Dialysis
ZWDJHLS025K 25K Lite - No audible alarmZWDJHLS050K 50K Lite - No audible alarmZWDJHLS200K 200K Lite - No audible alarmZWDJHLS1MEG 1Meg Lite - No audible alarmZWDJHLS2MEG 2Meg Lite - No audible alarmZWDJHLA025K 25K Lite - Audible alarm*ZWDJHLA050K 50K Lite - Audible alarm*ZWDJHLA200K 200K Lite - Audible alarm*ZWDJHLA1MEG 1Meg Lite - Audible alarm*ZWDJHLA2MEG 2Meg Lite - Audible alarm*ZWDJHYTRANA 115VAC/12VDC TransformerZWDJHYPC Hy-Lite to Hy-Lite PatchcordZWDJRMA Remote Alarm ModuleZWDJRMAR Remote Alarm Module with Auto Re-Alarm*ZWDJRMR Relay ModuleZWDJRPCO50 50 ft. Hy-Lite to Module CableZWDJRPC100 100 ft. Hy-Lite to Module CableZWDJRPC200 200 ft. Hy-Lite to Module Cable
*For dialysis use only, add ZWDJRMAR module for Remote Monitoring
153
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
LIQUID LEVEL CONTROLS
Tank Level Controls
SYSTEM SPECIFICATIONS
Pressure Connection . . . . . . . . . 1/4" NPTFElectrical Connection . . . . . . . . . 3 - 7/8" diameter knockoutsSwitches. . . . . . . . . . . . . . . . . . . 3 - SPDT, 15 amp,
125/250/480 VACMounting . . . . . . . . . . . . . . . . . . In fixed position near reservoir
via attached bracket
System DimensionsH x W x D (inches). . . . . . . . . . . 41⁄4x51⁄4x43⁄4
Siemens tank level controllers are designed to control the on/off action of a
water system feeding a storage tank, as well as control the on/off of a booster
pump located at the discharge side of a storage tank. There are a variety of level
controllers available to satisfy a wide array of application needs.
• Each unit comes with three independently adjustable switches that can control
the action of three devices
• Switches are activated by the changing liquid level in the reservoir as sensed by
the units diaphragm sensor.
ORDERING INFORMATION
Catalog Number: ZRLC02003 ZRLC02004 ZRLC02005 ZRLC02006
Diaphragm . . . . . . . . . . . . . . . Buna-N Teflon® Teflon® Buna-NBellow and Connection . . . . . . #380 alloy 316 stainless 316 stainless #380 alloy
aluminum steel steel aluminumAdjustable Range . . . . . . . . . . 0-80" water 0-80" water 0–20 psi 0–20 psi
column columnDeadband. . . . . . . . . . . . . . . . 2.0–6.0" 3–7" water 0.1–0.6 psi 0.1–0.6 psi
water column column
154
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
METERS (CONDUCTIVITY /RESISTIVITY)
Thornton 200CR(S) Conductivity/ResistivityMeters
SYSTEM SPECIFICATIONS
Power . . . . . . . . . . . . . . . . . . . 90-130 VAC or 180-250 VAC to 24 VDC; 12 W max; 50/60 Hz
Operating Temp.. . . . . . . . . . . –10 to 55°C (14 to 131°F)Humidity . . . . . . . . . . . . . . . . . 0-95% RH (non-condensing)Ranges. . . . . . . . . . . . . . . . . . High-purity – 0.1 constant cell
0.02 µS/cm to 750 µS/cm0.0013 mΩ-cm to 50 MΩ-cmTDS: 0-62.5 k ppm (as NaCl)Temperature: -40°C to 140°C
Accuracy . . . . . . . . . . . . . . . . ±0.5% of reading up to 18 Magohm-cmRepeatability . . . . . . . . . . . . . ±0.1% for resistance and ±0.075°C for temperatureTemp. Accuracy . . . . . . . . . . . ±0.25°C of readingRelays . . . . . . . . . . . . . . . . . . 2 SPDT relays, each rated for max of 5 amp up to
30VDC or 250 VAC; 4 solid state, each rated formax 1.5 amp, 250 VAC 50mA min current
Display . . . . . . . . . . . . . . . . . . 1 line, 16 character backlit LCD (4.8mm x 9.6mm)Enclosure . . . . . . . . . . . . . . . . ABS-PC alloy; panel cut required 3.78 x 7.56" DINWeight . . . . . . . . . . . . . . . . . . 1.9 lb (0.9 kg)Keypad . . . . . . . . . . . . . . . . . . 11 tactile feedback keysSetpoints . . . . . . . . . . . . . . . . 4 controlled setpoints can be set as low or high limit. Any
setpoint can be programmed to operate up to 4 output relays.
MeasurementUpdate Rate . . . . . . . . . . . . . . Once per secondTwo Analog. . . . . . . . . . . . . . . Output value is proportioned to the selected Output Signals measurement signal. Outputs scaled from 4-20 mA;
500 ohm load max.Analog Output Accuracy . . . . 0.01 mASerial Output . . . . . . . . . . . . . RS232/max distance 500 ft; RS422/max distance 4K ft. Field
selectable up to 19.2 k band.
Sensor Patch CordLength . . . . . . . . . . . . . . . . . . Max. distance sensor to meter is 200 ft. Patch cord is required
for each sensor.Temp.Compensation . . . . . . . Automatic, reference to 25°C for resistivity, conductivity,
percent rejection and TDS.
ORDERING INFORMATIONModel 200CR - Two channel monitoring
Model 200 CRS - Single channel monitoringCatalog No.
200CR Res/Con Meter 115VAC . . . . . . . . . . . . ZMET62201200CR Meter w/4-20 mA 115VAC . . . . . . . . . . . ZMET62221200CR Meter w/4 SS Relays & 4-20 mA 115VAC ZMET62421200CRS Meter w/2 Relays & 4-20 mA 115VAC ZMET61221200CRS Package (w/Cord & Sensor) . . . . . . . . ZPAK580211220.1C Sensor 200 CR
Titanium/Ryton (1.35") 3/4" NPT . . . . . . . . . . ZCEL240201Titanium/Ryton (5.19") 3/4" NPT . . . . . . . . . . ZCEL240202Monel/Ryton (1.35") 3/4" NPT . . . . . . . . . . . . ZCEL240203Monel/Ryton (5.19") 3/4" NPT . . . . . . . . . . . . ZCEL240204Titanium/PEEK (1.35) 3/4" NPT Ozone . . . . . ZCEL240205Titanium/PEEK (5.19") 3/4" NPT Ozone . . . . ZCEL240206Titanium/Noryl (1.14" insertion length) 1/2" NPT ZCEL240213Titanium/Noryl (1.14" insertion length) 3/4" NPT ZCEL240214Titanium/PEEK 1.5" Tri-clamp . . . . . . . . . . . . ZCEL243201316LSS/PEEK 1.5" Tri-clamp Pharm. . . . . . . ZCEL243203Titanium/PEEK 2" Tri-clamp. . . . . . . . . . . . . . ZCEL243205316LSS/PEEK 2" Tri-clamp . . . . . . . . . . . . . . ZCEL243207
200CR(S) Patch Cord 1' . . . . . . . . . . . . . . . . . . ZCOR100166200CR(S) Patch Cord 5' . . . . . . . . . . . . . . . . . . ZCOR100566200CR(S) Patch Cord 10' . . . . . . . . . . . . . . . . . ZCOR101066200CR(S) Patch Cord 25' . . . . . . . . . . . . . . . . . ZCOR102566200CR(S) Patch Cord 50' . . . . . . . . . . . . . . . . . ZCOR105066200CR(S) Patch Cord 100' . . . . . . . . . . . . . . . . ZCOR111066200CR(S) Patch Cord 150' . . . . . . . . . . . . . . . . ZCOR111566200CR(S) Patch Cord 200' . . . . . . . . . . . . . . . . ZCOR112066NEMA rear enclosure . . . . . . . . . . . . . . . . . . . . P92470Pipe mounting bracket. . . . . . . . . . . . . . . . . . . . ZAC100063800 Series instrument adapter plate . . . . . . . . . ZAC100064High res/low cond calib kit (calib #1 & #2) . . . . ZCAL186501Low res/high cond calib kit (calib #3 & #4) . . . . ZCAL186502Complete calibration kit (contains all 4 calibrators) ZCAL186503Individual calibrator #1–4 Mohm/104°C . . . . . . ZCAL186401Individual calibrator #2–100,000 Ohm/0°C . . . . ZCAL186402Individual calibrator #3–20,000 Ohm/104°C . . . ZCAL186403Individual calibrator #4–1,000 Ohm/0°C . . . . . . ZCAL18640418.18MW-cm @ 25°C Verifier . . . . . . . . . . . . . . ZCAL186504
The Thornton 200CR and 200CRS are flexible meters allowing the user toconfigure the instrument to measure in the engineering units preferred by theoperator. An operator no longer needs to use one model for conductivity andanother for resistivity, percent rejection (200CR) or a specific range ofmeasurement.
• Measures conductivity (1 S/cm to 0.02 µS/cm), resistivity (1.0Ω-cm to 50.0MΩ-cm), Temperature (–10 to 140°C and/or +14 to 284°F), TDS, (ppm/ppb), Percentrejection (0-99%), Difference (A–B, B–A), Ratio (A/B, B/A), % chemicalconcentration for HCl, H2SO4, NaOH. Each of two channels can be set up tomeasure two of these parameters. A total of four different measurements canbe programmed.
• Wide measurement range; Backlit LCD display
• NEMA 4X housing and cable connectors. 200 foot sensor cable per channel
• Designed to meet CDS/NRTL standards, calibration with NIST traceability
155
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
METERS (TOTAL ORGANIC CARBON)
Thornton Total Organic Carbon System
The Thornton Total Organic Carbon (TOC) system is comprised of the 770MAX
multi parameter analyzer transmitter and the 5000TOC Sensor. The sensor /
analyzer uses proven ultraviolet oxidation with differential conductivity to
effectively measure TOC concentrations. The smart sensor design minimizes set-
up time to just minutes while the continuous flow design provides rapid TOC
response which are far superior then traditional batch measurement systems.
Benefits:
• No gases or reagents to handle, store or replace. No moving parts minimize
routine maintenance and service intervals.
• Sensor concept allows easy and economical integration into water purification
make-up and distribution systems.
• Easily added to existing APEX™ or PreVUE® systems which currently use
770MAX controller
• Meets USP <643>, <645> and EP 2.2.44 requirements for Pharmaceutical
Industry
• Ultra low TOC detection (< 1 ppb) for UPW water applications to continuously
monitor critical organic levels in semiconductor make-up, distribution and
process systems
• Compact, sealed NEMA 4 enclosure for demanding industrial environments
• 770MAX can accommodate additional sensor measurements for a total of 6
sensors including conductivity / resistivity TOC, temperature, flow, pH, DO, ORP,
and ozone.
SYSTEM SPECIFICATIONS
Measurement Range 0.05 -1000 (ppb C) Repeatability + 0.05 ppb C < 5 ppb + 1.0% > 5 ppbAccuracy +0.1 ppb C for TOCResolution 0.001 ppb CAnalysis Time ContinuousResponse Time < 60 secondsLimit of Detection 0.025 ppb CConductivity Cell Constant Accuracy +2%Temperature Sensor Pt1000 RTD, Class ATemperature Accuracy +0.25˚C @ 25˚C
SAMPLE WATER REQUIREMENTS
Temperature - 0 to 90˚CParticle Size - 100 micronMinimum Water Quality – 0.5 M-Ohm (2.0 vS/cm) Flow Rate – 20mL/minPressure – 15 to 100 psig at sample inlet connection
GENERAL SPECIFICATIONS
Overall Dimensions – 11" W x 7.4" H x 5.25" DSample Connections – Inlet 0.125" (3mm) O.D. compression-type (femule)
tube connection with 0.25 adapter Outlet 0.25" (6mm) O.D. Barb connection
ORDERING INFORMATION
Catalog No. Description
ZPAK58036013 StandardThornton TOC system, 110V (includes 5000TOC Sensor, 770MAX Analyzer /Transmitter, and 25" patch cord)
Z5TOC58079510 Replacement UV Lamp
Pharmaceutical OptionsZ5TOC58091534 System Suitability/Calibration Test kit
Z5TOC58091526 System Suitability Standards*
Z5TOC58091529 Calibration Standards * (500 ppb & 250 ppb)
Z5TOC58091527 Validation Support Documents
* perishable – max 4-week shelf life
156
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
MULTIMEDIA FILTERS
AVGF® Gravity FiltersFlow Rates from 14 to 1,472 gpm
AVGF® Gravity Filters operate automatically without a single valve, backwash pump,flow control or other instrumentation. Nothing moves but the water. The designand performance of the AVGF® filter has been proven through years of continuoususe at hundreds of water treatment facilities worldwide. Widely used inpretreatment plants for boiler feedwater, generating stations, pulp and paper millsand chemical plants, the AVGF® filter is also approved by a majority of states fortreatment of potable water supplies.
• For process water, potable water, iron removal and cooling tower sidestreams
• Requiring little labor or maintenance, the AVGF® filter operates by itself – filtering,backwashing, rinsing and returning to service without the use of valves, timers orswitches
• Unique design, including the discharge of filtered water above the filter bed,results in consistent high-quality effluent water
• The AVGF® filter rinse water is not discharged to drain, but stored and used forthe next backwash cycle to save water
ORDERING INFORMATIONFor Permutit® products and information contact 908.704.9027.
SYSTEM SPECIFICATIONS
Model Number AVGF-3 AVGF-4 AVGF-5 AVGF-6 AVGF-7 AVGF-8 AVGF-9 AVGF-10 AVGF-11Flow Rate
2 gpm/sq. feet . . . . . . . . . . . . 14 gpm 25 gpm 39 gpm 56 gpm 77 gpm 100 gpm 127 gpm 157 gpm 190 gpm3 gpm/sq. feet. . . . . . . . . . . . 21 gpm 38 gpm 59 gpm 85 gpm 115 gpm 151 gpm 191 gpm 236 gpm 285 gpm
Wash Water Flow Rate. . . . . . . 147 gpm 263 gpm 412 gpm 594 gpm 809 gpm 1,056 gpm 1,336 gpm 1,649 gpm 1,995 gpm
System DimensionsFilter Tank Diameter (feet) . . . . 3' 4' 5' 6' 7' 8' 9' 10' 11'. . . . . . . . . . . . . . . . . . . . . . . . . Remaining dimensions vary depending on type and tank diameter. Please request a product specification sheet for dimensions, . . . . . . . . . . . . . . . . . . . . . . . . . overall height is 252".
Pipe SizeInlet/Outlet . . . . . . . . . . . . . . . . 2" 2-1/2" 3" 4" 4" 6" 6" 6" 8"Drain . . . . . . . . . . . . . . . . . . . . . 6" 8" 8" 10" 10" 12" 12" 14" 14"
Shipping WeightIndustrial lb. . . . . . . . . . . . . 2,600 3,500 4,400 5,400 6,300 7,300 8,500 9,700 11,200
kg . . . . . . . . . . . . 1,179 1,588 1,996 2,449 2,858 3,311 3,856 4,400 5,080Municipal lb. . . . . . . . . . . . . 3,400 4,200 5,400 6,500 7,500 9,000 10,400 11,500 14,100
kg . . . . . . . . . . . . 1,542 1,905 2,450 2,948 3,402 4,082 4,717 5,216 16,396
SYSTEM SPECIFICATIONS
Model Number AVGF-12 AVGF-13 AVGF-14 AVGF-15 AVGF-16 AVGF-18 AVGF-20 AVGF-22 AVGF-25Flow Rate
2 gpm/sq. feet . . . . . . . . . . . . 226 gpm 265 gpm 308 gpm 353 gpm 402 gpm 509 gpm 629 gpm 760 gpm 982 gpm3 gpm/sq. feet. . . . . . . . . . . . 339 gpm 398 gpm 462 gpm 530 gpm 603 gpm 763 gpm 943 gpm 1,140 gpm 1,472 gpmWash Water Flow Rate . . . . . 2,373 gpm 2,787 gpm 3,232 gpm 3,711 gpm 4,223 gpm 5,345 gpm 6,598 gpm 7,982 gpm 10,300 gpm
System DimensionsFilter Tank Diameter (feet) . . . . 12' 13' 14' 15' 16' 18' 20' 22' 25'. . . . . . . . . . . . . . . . . . . . . . . . . Remaining dimensions vary depending on type and tank diameter. Please request a product specification sheet for dimensions, . . . . . . . . . . . . . . . . . . . . . . . . . overall height is 252".
Pipe SizeInlet/Outlet . . . . . . . . . . . . . . . . 8" 8" 8" 10" 10" 10" 12" 12" 14"Drain . . . . . . . . . . . . . . . . . . . . . 14" 15" 16" 18" 18" 20" 24" 24" 30"
Shipping WeightIndustrial lb. . . . . . . . . . . . . 12,200 13,700 15,100 16,100 17,300 21,200 25,200 29,000 34,500
kg . . . . . . . . . . . . 5,534 6,214 6,849 7,303 7,847 9,616 11,430 13,154 15,550Municipal lb. . . . . . . . . . . . . 15,600 17,400 19,700 22,300 25,000 30,100 34,800 41,500 48,300
kg . . . . . . . . . . . . 7,076 7,893 8,936 10,124 11,340 13,653 17,237 18,825 21,908
157
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
MULTIMEDIA FILTERS
KF Series Multimedia FiltersFlow Rates from 1 to 70 gpm
KF Series Multimedia Filters are ideal for commercial and light industrial filtration
applications where the advantages of a lightweight, corrosion-resistant FRP pressure
vessel and cost-effective top mounted valve are desirable.
• Tank liners are blow molded plastic wrapped with high-strength epoxy resin and
fiberglass for worry-free service
• Includes a motorized control valve that is quiet, efficient and dependable
• Electromechanical timer allows automatic backwash
• Includes a pretreatment lock-out switch assembly to deactivate downstream equipment
during backwash
Requires field assembly.
SYSTEM SPECIFICATIONS
Series KFZMS
APPLICATIONSTank Size Pipe Commercial RO-Feed* Backwash Media Dimensions Shipping WeightD x H (in) Size (in) Service Flow Service Flow Flow Volume (ft3) LxDxH (in) lb (kg)
10x40 1.0 5 gpm 4 gpm 8 gpm 1.0 10x10x50 160 (73)12x52 1.0, 1.5 8 gpm 6.4 gpm 12 gpm 1.6 12x12x63 320 (146)14x65 1.0, 1.5 10 gpm 8 gpm 15 gpm 2.1 14x14x76 469 (213)16x65 1.0, 1.5 14 gpm 11.2 gpm 20 gpm 2.9 16x16x76 630 (286)18x65 1.0, 1.5 18 gpm 14.4 gpm 25 gpm 4.0 18x18x75 670 (304)21x62 1.5, 2.0 24 gpm 19.2 gpm 35 gpm 4.9 21x21x74 1110 (504)24x72 1.5, 2.0 32 gpm 25.6 gpm 45 gpm 6.9 24x24x90 1500 (681)30x72 2.0 49 gpm 39.2 gpm 70 gpm 10.0 30x30x96 1570 (713)36x72 2.0 70 gpm 56 gpm 100 gpm 14.5 36x36x97 2130 (967)
*Flow is based on 8 gpm/ft2
ORDERING INFORMATION
Catalog Number: KFZMS XXX F X Z F X X
System Name . . . . . . . . . . . KFZMS 010, 012, 014,016, 018, 021,
Pressure Vessel Diameter (in inches) . . . . . . . . . . 024, 030, 036Pressure Vessel Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F = non-code, fiberglassControl Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X = Std NEMA 3R equivalentLevel of Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z = Stand alone A= 1.0"Backwash/Regeneration Initiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F = Timeclock NEMA3R (equivalent) B = 1.5" X = NoInlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C = 2.0"
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Options
To determine your catalog order number, replace the X with one of the numbered options below it.
These filters are also available as duplex units. Please contact our Technical Support team for more information.†All sizes not available with every tank size.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
158
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SYSTEM SPECIFICATIONSModel Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . VPEF/VPAF-024 VPEF/VPAF-630 VPEF/VPAF-636 VPEF/VPAF-742Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Good. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 70 105 140Better. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 60 85 115Best. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 40 55 75
Backwash Flow Rate. . . . . . . . . . . . . . . . . . . . . . . . 47 74 106 144Media (cubic feet)* . . . . . . . . . . . . . . . . . . . . . . . . . . 7.8 13.3 17.7 24.0System Dimensions**Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/2” 2” 2-1/2” 2-1/2”Column Size (D x H) . . . . . . . . . . . . . . . . . . . . . . . .
inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24x48 30x60 36x60 42 x 72cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61x122 77x153 92x153 107x183
**H x W x D Simplex (Duplex) – inch . . . . . . . . . . 76x42x41 (80x97x41) 90x42x48 (94x97x48) 96x40x55 (97x97x57) 112x43x60 (116x133x60)**H x W x D Simplex (Duplex) –cm . . . . . . . . . . . 193x107x104 (204x246x104) 229x107x123 (239x246x122) 244x102x140 (247x246x145) 285x109x152 (295x338x152)Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . 1,530 (3,060) 2,240 (4,480) 3,410 (6,820) 4,820 (9,640)kg – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . 694 (1,388) 1,017 (2,033) 1,547 (3,094) 2,186 (4,372)
Operating Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . lb. – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . 2,330 (4,660) 3,500 (7,000) 5,600 (11,200) 7,800 (15,600)kg – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . 1,057 (2,114) 1,588 (3,176) 2,541 (5,081) 3,538 (7,076)
Electrical Requirements. . . . . . . . . . . . . . . . . . . . . . 110 V / 60 Hz / 1 ph / 3 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . VPEF/VPAF-648 VPEF/VPAF-754 VPEF/VPAF-760 VPEF/VPAF-772Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Good. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 235 290 420Better. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 190 230 335Best. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 125 150 225
Backwash Flow Rate. . . . . . . . . . . . . . . . . . . . . . . . 188 239 295 424Media (cubic feet)* . . . . . . . . . . . . . . . . . . . . . . . . . . 31.4 39.8 49.1 70.6System Dimensions**Pipe Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3” 3” 4” 4”Column Size (D x H) . . . . . . . . . . . . . . . . . . . . . . . .
inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48x60 54x72 60x72 72x72cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122x153 139x183 153x183 183x183
H x W x D Simplex (Duplex) – inch . . . . . . . . . . . 106x58x67 (106x133x67) 121x61x75 (123x158x75) 125x68x88 (127x158x88) 125x68x88 (131x158x100)H x W x D Simplex (Duplex) –cm . . . . . . . . . . . . . 269x147x170 (269x338x170) 307x155x191 (312x401x191) 318x173x224 (323x401x224) 318x173x224 (333x401x254)Shipping Weight
lb. (kg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,200 (12,400) 8,300 (16,600) 10,435 (20,870) 14,980 (29,960)kg – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . 2,813 (5,625) 3,765 (7,530) 4,733 (9,466) 6,795 (13,590)
Operating Weightlb. – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . 10,160 (20,320) 13,320 (26,640) 16,765 (33,530) 24,110 (48,220)kg – Simplex (Duplex) . . . . . . . . . . . . . . . . . . . . . 4,609 (9,217) 6,042 (12,084) 7,604 (15,208) 10,936 (21,872)
Electrical Requirements. . . . . . . . . . . . . . . . . . . . 110 V / 60 Hz / 1 ph / 3 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*Filtration media includes 18" of Anthracite (0.85-0.95 mm), 8" of Filter Sand (0.45-0.55 mm) and 4" of Garnet (0.3 mm).**Approximate
ORDERING INFORMATIONVP Series Multimedia Filters have extensive option packages. For ordering instructions, or additional product information, please contact technical support at 800.875.7873 extension 5000.
MULTIMEDIA FILTERS
VP Series Multimedia FiltersFlow Rates from 25 to 420 gpm
VP Series Multimedia Filters are a low cost, reliable and efficient way to purify water.
These rugged, pre-engineered, pre-assembled units minimize installation and start-
up costs and are ideal for boiler feed, process water or rinse water applications.
• VPEF denotes non-ASME code vessels offered with express delivery
• VPAF denotes ASME code vessels with stamp available
• Simple design maximizes reliability and efficiency
• 100 psig vessel rating offers added strength and integrity
• Structural steel legs (seismic zone 4) provide rigid support of vessel for safety
• Skid mount (seismic zone 4) with structural steel beams for duplex systems
• Backwash and regeneration controls are highly reliable
• Optional metallic piping ensures long life and durability
• Standard epoxy internal and external coating extends vessel life
• Schedule 80 PVC piping enhances corrosion-resistance
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
PUMPS, CENTRIFUGAL
Multiple Stage Centrifugal Booster PumpsVictaulic® Type Pumps
SPECIFICATIONS – please contact Technical Support to obtain pump curvesMODEL NUMBER CRN3-3 CRN3-4 CRN3-5 CRN3-7 CRN3-8 CRN3-10
Catalog Number . . . . . . . . . . . . . . . . . GPC96083742 GPC96083744 GPC96083746 GPC96083750 GPC96083752 GPC96083756Nominal Flow Rate (gpm) . . . . . . . . . . 15 @ 35 psi 15 @ 39 psi 15 @ 52 psi 15 @ 71 psi 15 @ 95 psi 15 @ 104 psiPump Efficiency . . . . . . . . . . . . . . . . . 58% 58% 58% 58% 58% 58%Max Discharge Head (psi) . . . . . . . . . 41 54 69 95 108 136Max Oper Pressure (psi) . . . . . . . . . . 360 psi 360 psi 360 psi 360 psi 360 psi 360 psiMin Continuous Flow (gpm) . . . . . . . . 1.5 1.5 1.5 1.5 1.5 1.5Nameplate Horsepower . . . . . . . . . . . 0.5 HP 0.75 HP 0.75 HP 1.5 HP 1.5 HP 2.0 HPMotor Type/Service Factor . . . . . . . . . TEFC TEFC TEFC TEFC TEFC TEFCShipping Weight (lb) . . . . . . . . . . . . . . 50.5 48.4 48.9 63.5 66.3 73Electrical Requirements . . . . . . . . . . . 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . 1-1/4-inch Victaulic type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MODEL NUMBER CRN5-3 CRN5-5 CRN5-6 CRN5-7 CRN5-8 CRN5-10
Catalog Number . . . . . . . . . . . . . . . . . GPC96084823 GPC96084827 GPC96084829 GPC96084831 GPC96084833 GPC96084837Nominal Flow Rate (gpm) . . . . . . . . . . 30 @ 28 psi 30 @ 52 psi 30 @ 63 psi 30 @ 74 psi 30 @ 82 psi 30 @ 106 psiPump Efficiency . . . . . . . . . . . . . . . . . 65% 65% 65% 65% 65% 65%Max Discharge Head (psi) . . . . . . . . . 41 69 84 97 113 141Max Oper Pressure (psi) . . . . . . . . . . 360 psi 360 psi 360 psi 360 psi 360 psi 360 psiMin Continuous Flow (gpm) . . . . . . . . 3 3 3 3 3 3Nameplate Horsepower . . . . . . . . . . . 1 HP 1.5 HP 2 HP 3 HP 3 HP 3 HPMotor Type/Service Factor . . . . . . . . . TEFC TEFC TEFC TEFC TEFC TEFCShipping Weight (lb) . . . . . . . . . . . . . . 50.5 65.9 71.9 91.2 92.8 94.6Electrical Requirements . . . . . . . . . . . 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . 1-1/4-inch Victaulic type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MODEL NUMBER CRN10-2 CRN10-3 CRN10-4 CRN10-5 CRN15-3 CRN15-4 CRN15-6 CRN15-7
Catalog Number GPC96523104 GPC96523105 GPC96523106 GPC96523255 GPC96523707 GPC96523708 GPC96523710 GPC96523711Rated Flow (gpm) 53 @ 31 psi 53 @ 49 psi 53 @ 65 psi 53 @ 83 psi 90 @ 66 psi 90 @ 89 psi 90 @ 130 psi 90 @ 156 psiPump Efficiency 70% 70% 70% 70% 70% 70% 70% 70%Max Discharge Head (psi) 40 65 85 105 85 105 170 195Max Oper Pressure (psi) 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 360 psiMin Continuous Flow (gpm) 5.5 5.5 5.5 5.5 8.5 8.5 8.5 8.5Nameplate Horsepower 1.5 HP 3 HP 3 HP 5 HP 5 HP 7.5 HP 10 HP 15 HPMotor Type/Service Factor TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15Shipping Weight (lb) 101 139 141 164 159 184 223 278Electrical Requirements . . . . . . . . . . . 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inlet/Outlet Victaulic Style. . . . . . . . . . 2-inch Victaulic type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vertical, multi-stage centrifugal pumps are designed with the motor mounted directly on topof the pump housing to minimize footprint. Pump suction/discharge chamber, impellers,pump shaft, diffuser chambers, outer discharge sleeve, and impeller seal ring retainers areconstructed of 316 stainless steel. The motor stool is constructed of cast iron and is isolatedfrom the process fluid by a 316 stainless steel insert. Each pump is equipped with a hightemperature mechanical seal assembly. Pumps are capable of operating at continuoustemperatures up to 250°F (121°C). The pump motor is sized to ensure non-overloading whenoperating on the pump curve. Motors are totally enclosed fan cooled (TEFC), with NEMA Cface designs that provide a minimum service factor of 1.15. Lower motor bearings areadequately sized to ensure long motor life.
ORDERING INFORMATION
Victaulic Sets Size Catalog No.
Victaulic Connector Set Available 1-1/4" P90348Victaulic Connector Set Available 2" P90349
High Capacity Pumps available. Call Technical Support.
159
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
160
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
PUMPS, CENTRIFUGAL
Multiple Stage Centrifugal Booster PumpsANSI Flange
MODEL NUMBER CRN3-3 CRN3-4 CRN3-5 CRN3-7 CRN3-8 CRN3-10
Catalog Number . . . . . . . . . . . . . . . . . GPC96083922 GPC96083924 GPC96083926 GPC96083930 GPC96083932 GPC96083936Nominal Flow Rate (gpm) . . . . . . . . . . 15 @ 35 psi 15 @ 39 psi 15 @ 52 psi 15 @ 71 psi 15 @ 95 psi 15 @ 104 psiPump Efficiency . . . . . . . . . . . . . . . . . 58% 58% 58% 58% 58% 58%Max Discharge Head (psi) . . . . . . . . . 41 54 69 95 108 136Max Oper Pressure (psi) . . . . . . . . . . 360 psi 360 psi 360 psi 360 psi 360 psi 360 psiMin Continuous Flow (gpm) . . . . . . . . 1.5 1.5 1.5 1.5 1.5 1.5Nameplate Horsepower . . . . . . . . . . . 0.5 HP 0.75 HP 0.75 HP 1.5 HP 1.5 HP 2.0 HPMotor Type/Service Factor . . . . . . . . . TEFC TEFC TEFC TEFC TEFC TEFCShipping Weight (lb) . . . . . . . . . . . . . . 58.4 56.3 56.9 72.5 75.4 80.9Electrical Requirements . . . . . . . . . . . 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . 1-1/4-inch ANSI Flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MODEL NUMBER CRN5-3 CRN5-5 CRN5-6 CRN5-7 CRN5-8 CRN5-10
Catalog Number . . . . . . . . . . . . . . . . . GPC96085013 GPC96085017 GPC96085019 GPC96085021 GPC96085023 GPC96085027Nominal Flow Rate (gpm) . . . . . . . . . . 30 @ 28 psi 30 @ 52 psi 30 @ 63 psi 30 @ 74 psi 30 @ 82 psi 30 @ 106 psiPump Efficiency . . . . . . . . . . . . . . . . . 65% 65% 65% 65% 65% 65%Max Discharge Head (psi) . . . . . . . . . 41 69 84 97 113 141Max Oper Pressure (psi) . . . . . . . . . . 360 psi 360 psi 360 psi 360 psi 360 psi 360 psiMin Continuous Flow (gpm) . . . . . . . . 3 3 3 3 3 3Nameplate Horsepower . . . . . . . . . . . 1 HP 1.5 HP 2 HP 3 HP 3 HP 3 HPMotor Type/Service Factor . . . . . . . . . TEFC TEFC TEFC TEFC TEFC TEFCShipping Weight (lb) . . . . . . . . . . . . . . 58.4 74.9 79.8 99.1 100.7 102.5Electrical Requirements . . . . . . . . . . . 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . 316 stainless steel with mechanical silicon carbide seal faces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . 1-1/4-inch ANSI Flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MODEL NUMBER CRN10-2 CRN10-3 CRN10-4 CRN10-5 CRN15-3 CRN15-4 CRN15-6 CRN15-7
Catalog Number GPC96523118 GPC96523119 GPC96523120 GPC96523265 GPC96523718 GPC96523719 GPC96523721 GPC96523722Rated Flow (gpm) 53 @ 31 psi 53 @ 49 psi 53 @ 65 psi 53 @ 83 psi 90 @ 66 psi 90 @ 89 psi 90 @ 130 psi 90 @ 156 psiPump Efficiency 70% 70% 70% 70% 70% 70% 70% 70%Max Discharge Head (psi) 40 65 85 105 85 105 170 195Max Oper Pressure (psi) 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 360 psi 360 psiMin Continuous Flow (gpm) 5.5 5.5 5.5 5.5 8.5 8.5 8.5 8.5Nameplate Horsepower 1.5 HP 3 HP 3 HP 5 HP 5 HP 7.5 HP 10 HP 10 HPMotor Type/Service Factor TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15Shipping Weight (lb) 110 150 152 175 170 194 234 370Electrical Requirements . . . . . . . . . . . 208-230/460 V, 3 phase, 60 Hz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump Configuration . . . . . . . . . . . . . . Vertical, multiple stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . 316 stainless steel with cast iron flange and base plate* and mechanical silicon carbide seal faces . . . . . . . . . . Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . 2-inch ANSI Flange type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*Cast iron flange and base plate does not come in contact with pumped liquid. High Capacity Pumps available. Call Technical Support.
Vertical, multi-stage centrifugal pumps are designed with the motor mounted directly ontop of the pump housing to minimize footprint. Pump suction/discharge chamber,impellers, pump shaft, diffuser chambers, outer discharge sleeve, and impeller seal ringretainers are constructed of 316 stainless steel. The motor stool and flanges areconstructed of cast iron and are isolated from the process fluid by 316 stainless steelinserts. Each pump is equipped with a high temperature mechanical seal assembly.Pumps are capable of operating at continuous temperatures up to 250°F (121°C). Thepump motor is sized to ensure non-overloading when operating on the pump curve.Motors are totally enclosed fan cooled (TEFC), with NEMA C face designs that provide aminimum service factor of 1.15. Lower motor bearings are adequately sized to ensurelong motor life.
161
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
PUMPS, FEEDWATER BOOSTER
Feedwater Booster Pumps
Siemens feedwater booster pumps are close-coupled, single stage, end suction design
capable of being serviced without disturbing piping connections. The pump casings are
self venting, with a center line discharge design, and are fabricated of 304 stainless
steel casing seal ring. The enclosed-type impeller is constructed of 304 stainless steel. It
is dynamically balanced, keyed to the steel shaft and secured by a 304 stainless steel
capscrew.
The liquid cavity is sealed off at the pump shaft by an internally flushed mechanical seal
with stainless steel metal parts, Buna-N elastomers and carbon to ceramic faces,
suitable for continuous operation at 225°F. A replaceable, aluminum-bronze, shaft-
sleeve completely covers the wetted area under the seal. Pumps are rated for 125 psi
(175 psi for Series 3531 Pumps) working pressure. All casings have a drain tapping.
Pump motors meet NEMA specifications, are totally enclosed fan cooled (TEFC), have
heavy-duty grease-lubricated ball bearings, and are sized to be non-overloading over the
entire pump range.
SPECIFICATIONS*3530 Series/MODEL NUMBER 3530-30-2 3530-30-3 3530-30-9 3530 3530-30-2 3530-30-3 3530-30-9
Catalog Number . . . . . . . . . . . . . . . . . PF1CB6NA4 PF1DB6NG4 PF1ED6NC4 PF3AB6NA4 PF3CB6NA4 PF3DB6NG4 PF3ED6NC4Design Capacity (gpm). . . . . . . . . . . . 27 @ 25 psid 35 @ 35 psid 76 @ 25 psid 5 @ 25 psid 27 @ 25 psid 35 @ 35 psid 76 @ 25 psidPump Efficiency . . . . . . . . . . . . . . . . . 52% 53% 61% 40% 52% 53% 61%Motor Horsepower . . . . . . . . . . . . . . . 1.0 HP 1.5 HP 2.0 HP 0.5 HP 1.0 HP 1.5 HP 2.0 HPMotor Type/Service Factor . . . . . . . . . TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15 TEFC/1.15Electrical Requirements . . . . . . . . . . . 115/230V 115/230V 230/460V 230/460V 230/460V 230/460V 230/460V
16/8A; 1ph 20/20A; 1ph 12A; 3ph 24/12A; 3ph 3.6/1.8A; 3ph 5.2/2.6A; 3ph 6.8/3.4A; 3phPower at Full Load (KW) . . . . . . . . . . 0.83 1.2 1.6 1.6 0.83 1.2 1.6Pump Configuration . . . . . . . . . . . . . . Horizontal, closed-coupled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . 304 stainless steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inlet. . . . . . . . . . . . . . . . . . . . . . . . . . . 11⁄4" NPTF 11⁄4" NPTF 11⁄2" NPTF 11⁄2" NPTF 11⁄4" NPTF 11⁄4" NPTF 11⁄2" NPTFOutlet . . . . . . . . . . . . . . . . . . . . . . . . . 1" NPTF 1" NPTF 11⁄4" NPTF 11⁄4" NPTF 1" NPTF 1" NPTF 11⁄4" NPTFDimensions (WxLxH) inches . . . . . . . 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9 10.5x18.5x9Shipping Weight (lb) . . . . . . . . . . . . . . 41 45 45 37 41 45 45
3531 Series/MODEL NUMBER 1.25x1.5x5 1.5x2x5 2x2.5x5
Catalog Number . . . . . . . . . . . . . . . . . PF3GD5NE4 PF3HE5NE4 PF3IF5FC4Design Capacity (gpm). . . . . . . . . . . . 135 @ 35 psid 200 @ 30 psid 290 @ 35 psidPump Efficiency . . . . . . . . . . . . . . . . . 61% 59% 68%Motor Horsepower . . . . . . . . . . . . . . . 5.0 HP 7.5 HP 10.0 HPMotor Type/Service Factor . . . . . . . . . TEFC/1.15 TEFC/1.15 TEFC/1.15Electrical Requirements . . . . . . . . . . . 230/460V 230/460V 230/460V
15.2/7.6A; 3 ph 22/11A; 3 ph 28/14A; 3 phPower at Full Load (KW) . . . . . . . . . . 3.5 5.1 6.4Pump Configuration . . . . . . . . . . . . . . Horizontal, closed-coupled . . . . . . . . . . . . . Materials of Construction . . . . . . . . . . 304 stainless steel . . . . . . . . . . . . . . . . . . . . Inlet. . . . . . . . . . . . . . . . . . . . . . . . . . . 11⁄2" NPTF 2" NPTF 21⁄2" 150# flangeOutlet . . . . . . . . . . . . . . . . . . . . . . . . . 11⁄4" NPTF 11⁄2" NPTF 2" 150# flangeDimensions (WxLxH) inches . . . . 12x23x11 15x24x12 15x25x12Shipping Weight (lb) . . . . . . . . . . . . . . 101 130 175
*Please contact Technical Support to obtain pump curves
162
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS MEMBRANES
Replacement Reverse Osmosis (RO)Membranes
Manufacturer Size DxL Siemens Manufacturer’s Type Approx GPD % RejectCatalog No. Catalog No.
Ionpure 4 x 40 06/PL32364-01R PWS PFC-4 TFC 2300 99.6Ionpure 4 x 40 06/PL32364-02R PWS HS2-4 TFC 2800 99.6Ionpure 8 x 40 06/PL32364-04R PWS PFC-8 TFC 9000 99.6Ionpure 8 x 40 06/PL32364-06R PWS HS2-8 TFC 11200 99.6Filmtec 4 x 40 ROSTW4040 TW30-4040 TFC 2400 99.5Filmtec 4 x 40 CDRCLP4040 LP-4040 TFC 3200 99.2Filmtec 4 x 40 CDRCXLE4040 XLE-4040 TFC 2600 99.0Filmtec 4 x 40 CDRC4X40B BW30-4040 TFC 2400 99.5Filmtec 4 x 40 CDRCLE4X40B BW30LE-4040 TFC 2300 99.2Filmtec 4 x 40 CDRC4X40L RO-4040-FF TFC 2650 99.5Filmtec 4 x 40 CDRCF4040L379P HSRO-4040-FF TFC 1900 99.5Filmtec 4 x 40 CDRCSW304040 SW30-4040 TFC 1500 99.2Filmtec 8 x 40 CDRC30365 BW30-365 TFC 9500 99.5Filmtec 8 x 40 CDRC8X40D BW30-400 TFC 10500 99.5Filmtec 8 x 40 CDRC8X40LE BW30LE-440 TFC 11500 99.2Filmtec 8 x 40 CDRC30365FR BW30-365FR TFC 9500 99.5Filmtec 8 x 40 CDRCBW30400/34I BW30-400/34i TFC 10500 99.5Filmtec 8 x 40 CDRCBW30440I BW30-440i TFC 11500 99.5Filmtec 8 x 40 CDRCLE440I LE-440i TFC 12650 99.3Filmtec 8 x 40 CDRCSW30XLE400I SW30-400i TFC 9000 99.7Filmtec 8 x 40 CDRCSW30HRLE400I SW30HR-LE400i TFC 7500 99.8Filmtec 8 x 40 CDRCSW30HRLE400 SW30HR-LE400 TFC 7500 99.8Hydranautics 4 x 40 ROLSA4040 CPA2-4040 TFC 2250 99.2Hydranautics 4 x 40 CDHYESPA14040 ESPA1-4040 TFC 2600 99.0Hydranautics 4 x 40 CDHYESPA24040 ESPA2-4040 TFC 1900 98.0Hydranautics 4 x 40 CDHYESPA34040 ESPA3-4040 TFC 3000 98.0Hydranautics 4 x 40 CDHYESPA44040 ESPA4-4040 TFC 2500 99.2Hydranautics 4 x 40 CDHYSWC14040 SWC1-4040 TFC 1100 99.6Hydranautics 8 x 40 ROLSY8040 CPA2 TFC 10000 99.2Hydranautics 8 x 40 CDHYCPA3 CPA3 TFC 11000 99.6Hydranautics 8 x 40 CDHYCPA4 CPA4 TFC 6000 99.7Hydranautics 8 x 40 CDHYESPA1 ESPA1 TFC 12000 99.0Hydranautics 8 x 40 CDHYESPA2 ESPA2 TFC 9000 99.5Hydranautics 8 x 40 CDHYESPA3 ESPA3 TFC 15000 98.0Hydranautics 8 x 40 CDHYESPA4 ESPA4 TFC 12000 99.2Hydranautics 8 x 40 CDHYSWC3 SWC3 TFC 5900 99.6Hydranautics 8 x 40 CDHYSWC3PLUS SWC3+ TFC 7000 99.8Hydranautics 8 x 40 CDHYSWC4PLUS SWC4 TFC 6500 99.8Hydranautics 8 x 40 CDHYSWC5 SWC5 TFC 9000 99.8
Siemens is your leading source for replacement membranes. We supply elementsfrom all of the major manufacturers. For your convenience, we inventoryFILMTEC™ and Hydranautics® membranes at our regional distribution facilities.This enables us to meet short lead times and thereby minimize your systemdowntime. In addition, we also stock major components such as replacementgauges, pumps and end caps. Whether it involves normal wear-and-tearreplacement, maintenance or spares inventory, Siemens has the products tosupport your membrane system.
Items in BLUE are stocked by Siemens.For availability of other items, please contact your local Siemens sales representative.
163
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
REVERSE OSMOSIS MEMBRANES - OBSOLETE SIEMENS SYSTEMS
CARO RO Membrane Cartridges
• Spiral wound modules constructed of cellulose acetate membrane
• Designed to operate in Series 60, 120, 250, 350, M-1000/2000/3000 RO
systems, and other units
• Chlorine tolerant for sanitization
• Good salt rejection
• Competitive flux rates
• Ideal for medical, hemodialysis, pharmaceutical, biotechnology, food and
beverage and laboratory applications
PERFORMANCE AND PHYSICAL SPECIFICATIONSMR40 MR60 4 x 40 8 x 40
Initial Flow Rate @ 25°C/200 psi 1.0 L/min > 1.3 L/min 1360 gpd 7000 gpdInitial Rejection Monovalent Ions >90% >93% >96% >96%Initial Rejection Divalent Ions . . >95% >96%Length/in. (cm) . . . . . . . . . . . . . 25 (63.5) 25 (63.5) 40 (101.6) 40 (101.6)Diameter/in. (cm) . . . . . . . . . . . 3.5 (8.9) 3.84 (9.75) 4 (10.2) 8 (20.3)Diameter (unstressed chevron seal)/in. (cm) . . . . . . . . 3.74 (9.50) 4.21 (10.69) — —Membrane Surface Area (ft2) (m2). . . . . . . . . . . . . . . . . . . . . 40 (3.72) 60 (5.57)Product Tube Diameter/in. (cm). . — — 0.625 (1.59) 1.5 (3.81)
FEED WATER SPECIFICATIONSOperating Pressure. . . 140-400 psi Langelier Saturation Index of Reject<–0.5 ppmTemperature . . . . . . . . 2-35°C Free Chlorine. . . . . . . . . . . . . . . . . <1.5 ppmpH . . . . . . . . . . . . . . . . 4 - 7.5 Maximum Cartridge Recovery. . . . 15%Silt Density Index . . . . < 5 Maximum Feed Turbidity . . . . . . . . 1 NTU
ORDERING INFORMATIONRO System Cartridges Used Quantity RequiredMR40C CartridgesSeries 60 . . . . . . . . . . . . . . . . . CDRO 025 S1 1 eachSeries 120 . . . . . . . . . . . . . . . . CDRO 025 S1 1 each
CDRO 025 SH 1 eachSeries 250 . . . . . . . . . . . . . . . . CDRO 025 S1 1 each
CDRO 025 SH 2 eachSeries 350 . . . . . . . . . . . . . . . . CDRO 025 S1 1 each
CDRO 025 SH 3 eachMR60 CartridgesSeries 1000, 2000 . . . . . . . . . . CDRO M60 S1 Quantities vary, consult
Technical Support4x40/8x40 CartridgesSeries 2500, 3000 . . . . . . . . . . CDROFG440 (1/pk)Series 4000, 8400 . . . . . . . . . . CDROFG840 (1/pk)
Quantities vary, consult Technical Support
164
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
VANTAGE™ MicROFlow Rates from 0.1 to 1.6 gpm
SYSTEM SPECIFICATIONS
Model Number MCRO1 MCRO2 MCRO4 MCRO8 MCRO12 MCRO16
Product Flow* (gpm)................................ 0.1 0.17 0.4 0.8 1.2 1.6Feed Flow (gpm)...................................... 0.2 0.34 0.8 1.6 2.4 3.2Reject Flow (gpm).................................... 0.1 0.17 0.4 0.8 1.2 1.6Reject Recycle (gpm) .............................. 0.6 0.6 0.8 1.6 2.5 3.2
ConnectionsFeed Inlet................................................. 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPTProduct Outlet.......................................... 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPTReject to Drain Outlet .............................. 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT 3/8" FNPT
MembranesMembrane Size........................................ 2.5” diameter 2.5” diameter 2.5” diameter 2.5” diameter 2.5” diameter 2.5” diameterMembranes/Vessel .................................. 1 1 1 1 1 1Membrane Quantity ................................. 1 1 1 2 3 4VesselsVessel Staging ......................................... 1 1 1 1:1 1:1:1 1:1:1:1
System Dimensions**H x W x D . . . . . . . . . . . . .inches 48x28x10 48x28x10 48x28x10 48x28x10 48x28x10 48x28x10Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . .lb 47 50 53 57 61 65
Electrical RequirementsHigh Voltage Service ............................... 120V 1PH 120V 1PH 120V 1PH 120V 1PH 120V 1PH 120V 1PHHigh Voltage FLA..................................... 6.5 6.5 6.5 6.5 6.5 6.5
*Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters.**Does not include operating space requirements.
Vantage™ MicRO Series reverse osmosis units are designed and manufactured for
commercial applications. Each MicRO model consists of a single stage, positive
displacement, rotary vane pump, and tap water membranes. Each unit is fully tested
at the factory and only requires simple utility connections (feed water inlet, product
water outlet, drain and a power source).
Capabilities
• High pressure feed pump
• PVC end entry pressure vessels
• Spiral wound thin film composite (TFC) membranes
• Hand/Off/Auto switch for system operation
• Schedule 80 PVC product piping
• Electrical cord with male plug designed to be plugged into a standard 115VAC,
grounded receptacle
OPTIONAL ACCESSORIES
Catalog No. Description
MCRIP04 Prefilter gauge, feed water low-pressure switch, product flow meter, reject recycle flow meter for: MCRO1, MCRO2, MCRO4
MCRIP16 Prefilter gauge, feed water low-pressure switch, product flow meter, reject recycle flow meter for: MCRO8, MCRO12, MCRO16
MCRTL Tank level switch for all models
MCRSP Free standing mounting frame for all models
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
165
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
VANTAGE™ M21 Series RO Flow Rates from 0.4 to 1.6 gpm
Vantage™ Reverse Osmosis units are pre-engineered systems specifically designed for a
variety of industrial applications. Vantage™ systems offer you the greatest flexibility
possible from a standard system. The control system is an advanced microprocessor-
based system that is very easy to use.
Capabilities
• TFC (thin film composite) RO membranes ensure optimum water quality
• Microprocessor-based controller provides user-friendly programmable controls
• Small footprint minimizes required space
• Low energy membranes reduce operating costs
• Clean-in-place connections maximize system availability
• Dial-up capability enables real-time remote monitoring (optional)
SYSTEM SPECIFICATIONS
Model Number M21R001 M21R002 M21R003 M21R004
Product Flow* (gpm) . . . . . . . . . . 0.4 0.8 1.2 1.6Feed Flow (gpm) . . . . . . . . . . . . . 0.8 1.6 2.4 3.2Reject Flow (gpm) . . . . . . . . . . . . 0.4 0.8 1.2 1.6Reject Recycle (gpm) . . . . . . . . . 3.1 2.3 1.5 0.7ConnectionsFeed Inlet . . . . . . . . . . . . . . . . . . . 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPTProduct Outlet . . . . . . . . . . . . . . . 1/2” tube 1/2” tube 1/2” tube 1/2” tubeReject to Drain Outlet . . . . . . . . . 3/8” tube 3/8” tube 3/8” tube 3/8” tubeMembranesMembrane Quantity . . . . . . . . . . . 1 2 3 4Membrane Size . . . . . . . .(inches) 2.5x40 2.5x40 2.5x40 2.5x40VesselsVessel Array . . . . . . . . . . . . . . . . . 1 1:1 1:1:1 1:1:1:1System Dimensions**H x W x D
inches . . . . . . . . . . . . . . . . . . . 62x17x26 62x17x26 62x17x26 62x17x26cm . . . . . . . . . . . . . . . . . . . . . . 157x43x66 157x43x66 157x43x66 157x43x66
Shipping Weightlb . . . . . . . . . . . . . . . . . . . . . . . 80 90 100 110kg . . . . . . . . . . . . . . . . . . . . . . 36 41 45 50
*Product flow rates are based on equipment design parameters and may not be appropriate for other feed waters.**Does not include operating space requirements.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
ORDERING INFORMATION
Catalog Number: M21R 004 E DM21R . . . . . . . . . . . . . . . Vantage M21 Series RO 001 - 1 Membrane A - 120/240 VAC, 1 PH, 60 HZ
002 - 2 Membranes B - 208 VAC, 3 PH, 60 HZ003 - 3 Membranes C - 230 VAC, 3 PH, 60 HZ
Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 004 - 4 Membranes D - 460 VAC, 3 PH, 60 HZPackage Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - Economy E - 575 VAC, 3 PH, 60 HZVoltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F - 380 VAC, 3 PH, 50 HZ
166
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
VANTAGE™ M41 High Purity (HP) Series RO Flow Rates from 1.4 to 15 gpm
SYSTEM SPECIFICATIONS
Model Number* M41RHP001 M41RHP002 M41RHP003 M41RHP004 M41RHP005 M41RHP006
Product Flow** (gpm) 1.4 2.8 4.0 5.2 6.2 7.0Feed Flow (gpm) 2.8 5.6 8.0 6.9 8.3 9.3Reject Flow (gpm) 1.4 2.8 4.0 1.7 2.1 2.3Reject Recycle (gpm) 7.0 5.0 4.0 6.0 6.0 6.0ConnectionsFeed Inlet 1-1/2" Flange 1-1/2" Flange 1-1/2" Flange 1-1/2" Flange 1-1/2" Flange 1-1/2" FlangeProduct Outlet 3/4" NPT 3/4" NPT 3/4" NPT 3/4" NPT 3/4" NPT 3/4" NPTReject to Drain Outlet 3/4" NPT 3/4" NPT 3/4" NPT 3/4" NPT 3/4" NPT 3/4" NPTMembranesMembrae Size 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40Membrane Quantity 1 2 3 4 5 6VesselsVessel Staging 1 1:1 1:1:1 1:1:1:1 1:1:1:1:1 2:1:1:1:1System Dimensions***Shipping Weight . . . . . . . . . . . . . . . . . . . lb 550 575 600 625 650 675
Model Number* M41RHP008 M41RHP009 M41RHP012
Product Flow** (gpm) 10.0 12.0 15.0Feed Flow (gpm) 13.3 16.0 20.0Reject Flow (gpm) 3.3 4.0 5.0Reject Recycle (gpm) 8.0 11.0 10.0ConnectionsFeed Inlet 1-1/2" Flange 1-1/2" Flange 1-1/2" FlangeProduct Outlet 3/4" NPT 3/4" NPT 3/4" NPTReject to Drain Outlet 3/4" NPT 3/4" NPT 3/4" NPTMembranesMembrane Size 4 x 40 4 x 40 4 x 40Membrane Quantity 8 9 12VesselsVessel Staging 2:2:1:1:1:1 3:2:2:1:1 3:3:2:2:1:1System Dimensions***Shipping Weight . . . . . . . . . . . . . . . . . . . lb 750 775 850
*The 4 designates 4" housing, the 1 designates element in length, and the 0X designates the number of membranes.**Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters.***Does not include operating space requirements.
The Vantage™ M41RHP (High Purity) series RO units are designed and manufactured for
industrial applications. Units contain 4-inch membranes with flow rates of 1.4 to 15.0 gallons
per minute (0.32 to 3.4 m3
/hr). They arrive with membranes installed and only require simple
utility connections to begin operations. Their simple designs maximize reliability of the RO unit.
Capabilities
• TFC membranes (choice of full-fit or brackish water) ensure optimum water quality
• Microprocessor-based controller provides user-friendly programmable controls
• Clean-in-place connections maximize system availability and serviceability
• Optional modem is available to enable real-time remote monitoring
• Stainless steel high pressure piping and fittings
• Reject recycle maximizes water recovery and minimizes waste
167
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ORDERING INFORMATION
Catalog Number: M41RHP 012 E S DM41RHP . . . . . . . . . . . . . Vantage M41 High Purity RO 001 - 1 Membrane
002 - 2 Membranes003 - 3 Membranes004 - 4 Membranes005 - 5 Membranes006 - 6 Membranes008 - 8 Membranes009 - 9 Membranes B - 208 VAC, 3 ph, 60 Hz
Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 012 - 12 Membranes C - 230 VAC, 3 ph, 60 HzPackage Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - Economy S - BW30-4040 D - 460 VAC, 3 ph, 60 HzMembrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F - RO-4040-FF E - 575 VAC, 3 ph, 60 Hz
Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F - 380 VAC, 3 ph, 50 Hz
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
REVERSE OSMOSIS SYSTEMS
VANTAGE™ M41 High Purity (HP) Series RO Flow Rates from 1.4 to 15 gpm
168
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
VANTAGE™ M41 General Purpose (GP)Series RO Flow Rates from 1.4 to 10 gpm
SYSTEM SPECIFICATIONS
Model Number with centrifugal pump . . . . M41RGP001 M41RGP002 M41RGP003 M41RGP004 M41RGP005 M41RGP006 M41RGP008Product Flow* (gpm) . . . . . . 1.4 2.8 4.0 5.2 6.3 7.5 10Feed Flow (gpm) . . . . . . . . . 2.8 5.6 8.0 8.0 8.3 10.0 13.3Reject Flow (gpm) . . . . . . . . 1.4 2.8 4.0 2.8 2.0 2.5 3.3Reject Recycle (gpm) . . . . . 6.8 4.0 9.3 9.0 9.0 7.3 4.0ConnectionsFeed Inlet. . . . . . . . . . . . . . . 1-1/2”NPT 1-1/2”NPT 1-1/2”NPT 1-1/2”NPT 1-1/2”NPT 1-1/2”NPT 1-1/2”NPTProduct Outlet . . . . . . . . . . . 3⁄4” NPT 3⁄4” NPT 3⁄4” NPT 3⁄4” NPT 3⁄4” NPT 3⁄4” NPT 3⁄4” NPTReject to Drain Outlet . . . . . 3⁄4” NPT 3⁄4” NPT 3⁄4” NPT 3⁄4” NPT 3⁄4” NPT 3⁄4” NPT 3⁄4” NPTMembranesMembrane Quantity . . . . . . . 1 2 3 4 5 6 8Membrane Size. . . . (inches) 4x40 4x40 4x40 4x40 4x40 4x40 4x40VesselsVessel Array. . . . . . . . . . . . . 1 1:1 1:1:1 1:1:1:1 1:1:1:1:1 2:1:1:1:1 2:2:1:1:1:1System Dimensions**H x W x D. . . . . . . . . . . . . . . . . inches 72x38x34 72x38x34 72x38x34 72x38x34 72x38x34 72x38x34 72x38x34. . . . . . . . . . . . . . . . . . . . cm 183x97x86 183x97x86 183x97x86 183x97x86 183x97x86 183x97x86 183x97x86
Shipping Weight . . . . . . . . . . . . . . . . . . . . . lb 550 575 600 625 700 725 750. . . . . . . . . . . . . . . . . . . . . kg 250 261 273 284 318 330 341
*Product flow rates are based on equipment design parameters and may not be appropriate for other feed waters.
**Does not include operating space requirements.
Vantage™ Reverse Osmosis units are pre-engineered systems specifically designed for
a variety of industrial applications. Vantage™ systems offer the greatest flexibility
possible from a standard system. The control system is an advanced microprocessor-
based system that is very easy to use.
Capabilities
• TFC (thin film composite) RO membranes ensure optimum water quality
• Low energy membranes reduce operating costs
• Reject recycle maximizes water recovery and minimizes waste
• Clean-in-place connections maximize system availability
• Dial-up capability enables real-time remote monitoring (optional)
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
ORDERING INFORMATION
Catalog Number: M41RGP 008 E S DM41RGP . . . . . . . . . . . . . Vantage M41 General Purpose RO 001 - 1 Membrane
002 - 2 Membranes
003 - 3 Membranes
004 - 4 Membranes
005 - 5 Membranes
006 - 6 Membranes B -208 VAC, 3 ph, 60 Hz
Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 008 - 8 Membranes C -230 VAC, 3 ph, 60 Hz
Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - Economy D -460 VAC, 3 ph, 60 Hz
Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S - XLE-4040 E - 575 VAC, 3 ph, 60 Hz
Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F - 380 VAC, 3 ph, 50 Hz
169
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Vantage™ Reverse Osmosis units are pre-engineered systems specifically designed for
a variety of industrial applications. Vantage™ systems offer you the greatest flexibility
possible from a standard system. The control system is an advanced microprocessor-
based system that is very easy to use.
Capabilities
• TFC (thin film composites) RO membranes ensure optimum water quality
• Microprocessor-based controller provides user-friendly programmable controls
• Pre-engineered systems allow easy installation
• Clean-in-place connections maximize system availability
• Auxiliary equipment interface provides system-wide control
SYSTEM SPECIFICATIONS
Model Number M43R009 M43R012 M43R015 M43R018
Product Flow* (gpm) . . . . . . . . . . . . . . . . . 10.5 15 19 23
Feed Flow (gpm) . . . . . . . . . . . . . . . . . . . . 16.2 21.4 25.3 30.7Reject Flow (gpm) . . . . . . . . . . . . . . . . . . . 5.7 6.4 6.3 7.7
Connections
Feed Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . 2” 2” 2” 2”
Product Outlet . . . . . . . . . . . . . . . . . . . . . . 1-1/2” 1-1/2” 1-1/2” 1-1/2”
Reject to Drain Outlet . . . . . . . . . . . . . . . . 3/4” NPT 3/4” NPT 3/4” NPT 3/4” NPT
Membranes
Membrane Quantity . . . . . . . . . . . . . . . . . . 9 12 15 18
Membrane Size . . . . . . . . . . . . . . .(inches) 4x40 4x40 4x40 4x40
Vessels
Vessel Array . . . . . . . . . . . . . . . . . . . . . . . . 1:1:1 2:1:1 2:2:1 3:2:1
Pump
Pump Type . . . . . . . . . . . . . . . . . . . . . . . . . Vertical Multi-stage Vertical Multi-stage Vertical Multi-stage Vertical Multi-stage
System Dimensions**
H x W x Dinches . . . . . . . . . . . . . . . . . . . . . . . . . . 63x23x129 63x23x129 63x23x129 63x23x129
cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160x58x328 160x58x328 160x58x328 160x58x328
Shipping Weight
lb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1110 1250 1400 1550
kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505 568 636 705
*Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters.**Does not include operating space requirements.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
ORDERING INFORMATION
Catalog Number: M43R 018 E S DM43R . . . . . . . . . . . . . . . . Vantage M43 Series RO 009 - 9 Membrane
012 - 12 Membranes
015 - 15 Membranes B - 208 VAC, 3 ph, 60 Hz
Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 018 - 18 Membranes C - 230 VAC, 3 ph, 60 Hz
Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - Economy D - 460 VAC, 3 ph, 60 Hz
Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S - BW30LE-4040 E - 575 VAC, 3 ph, 60 Hz
Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F - 380 VAC, 3 ph, 50 Hz
REVERSE OSMOSIS SYSTEMS
VANTAGE™ M43 Series RO Flow Rates from 10.5 to 23 gpm
170
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
Vantage™ M83 Series ROFlow Rates from 30 to 100 gpm
GENERAL SYSTEM SPECIFICATIONS
General Electrical: UL, cUL Enclosures NEMA 12 or betterGeneral Control Specs: Economy – Controlled by Microprocessor
Plus – Controlled by Siemens PLC and user friendly touchscreen Human Machine Interface (HMI)
Deluxe (M83D) – M83P controls plus Variable Frequency Drive (VFD), pH/ORP monitor
Overall Dimensions*: 168” Length, 32” Wide, 77” Height (100 gpm Unit 89” Height)Key Materials of Construction: Painted carbon steel frame, PVC low pressure piping,
stainless steel high pressure pipingMembrane Type: Thin Film Composite brackish water and low energy
membranes (optional)Available Options: Seismic Zone 4 Anchorage Wet Stamp (CA); pH, ORP, or both
on Economy and Plus ModelsContact a Siemens representative for detailed specifications.
Vantage™ M83 Series packaged single-pass 8-inch reverse osmosis units aredesigned for industrial applications requiring high quality equipment with a fastdelivery and a competitive price.
Standard Features:• RO Prefilter
• ASME Code Vessels with Pressure Relief
• Three models: Economy, Plus, and Deluxe:
• Economy utilizes rotameters and a microprocessor
• Plus provides more flexibility via control with a Siemens PLC and a userfriendly touch screen HMI.
• Deluxe provides Siemens PLC/HMI, Variable Frequency Drive andcontrolled feed pump, “On-Board” integrated cleaning system, loose shipchemical tank and hoses, pH/ORP measurement.
Benefits:
• Four (4) week standard lead time keeps your project moving.
• Compact footprint saves valuable floor space.
• Dry contacts are provided for chemical feed, pretreatment equipment, storagetank levels, and pressure switches.
• With simple utility connections and easy to set up controls, the unit is ready forquick on-line service.
171REVERSE OSMOSIS SYSTEMS
Vantage™ M83 Series ROFlow Rates from 30 to 100 gpm
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SYSTEM SPECIFICATIONS
Model Number** M83R006 M83R009 M83R012 M83R015 M83R018Product Flow* (gpm)................................ 30 45 60 75 100Feed Flow (gpm)...................................... 40 60 80 100 133Reject Flow (gpm).................................... 10 15 20 25 33Reject Recycle (gpm) .............................. 10 5 5 3 3
ConnectionsFeed Inlet................................................. 2" 2" 2" 3" 3"Product Outlet.......................................... 1.5" 1.5" 2" 2" 3"Reject to Drain Outlet .............................. 1.5" 1.5" 1.5" 1.5" 1.5"
MembranesMembranes/Vessel .................................. 3 3 3 3 3Membrane Quantity ................................. 6 9 12 15 18VesselsVessel Staging ......................................... 1:1 1:1:1 2:1:1 2:2:1 3:2:1
System DimensionsShipping Weight . . . . . . . . . . . .lb 2,900 3,175 3,450 3,725 4,000
*Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters.**The 8 designates 8" housing, the 3 designates 3 elements in length, and the XXX designates the nominal design product flow rate at 65˚ (18.3˚C).
ORDERING INFORMATION
Catalog Number: M83R 018 E S Y DM83R . . . . . . . . . . . . . . . . Vantage M83 Series RO 006 - 6 Membranes
009 - 9 Membranes
012 - 12 Membranes
015 - 15 Membranes E - Economy
Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 018 - 18 Membranes P - Plus
Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D - Deluxe S - Standard (ILEC) Element
Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C - Cold Water (LE) Element Y - Divert Kit Included
Product Divert Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X - Divert Kit Not Included D - 460 VAC, 3 ph, 60 Hz
Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - 575 VAC, 3 ph, 60 Hz
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
172
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
Vantage™ M84 Series ROFlow Rates from 100 to 214 gpm
GENERAL SYSTEM SPECIFICATIONS
General Electrical: UL, cUL Enclosures NEMA 12 or betterGeneral Control Specs: Economy – Controlled by Microprocessor
Plus – Controlled by Siemens PLC and user friendly touchscreen Human Machine Interface (HMI), Ethernet
Deluxe –Plus controls with Variable Frequency Drive (VFD), pH and ORP monitors, Ethernet
Overall Dimensions*: 230” Length, 54” Wide, 90” Height (maximum dimensions)Key Materials of Construction: Painted carbon steel frame, PVC low pressure piping,
stainless steel high pressure pipingMembrane Type: Thin Film Composite brackish water and low energy
membranes (optional)Available Options: Seismic Zone 4 Anchorage Wet Stamp (CA); pH, ORP, or both
on Economy and Plus Models
Contact a Siemens representative for detailed specifications.
Vantage™ M84 Series packaged single-pass 8-inch reverse osmosis units aredesigned for industrial applications requiring high quality equipment with afast delivery and a competitive price.
Standard Features:• RO Prefilter
• ASME Code Vessels with Pressure Relief
• Product Divert Kit with ASME Code Pressure Relief Valve (Loose Shipped)
• Three models: Economy, Plus, and Deluxe:
• Economy utilizes rotameters and a microprocessor
• Plus provides more flexibility via control with a Siemens PLC and auser friendly touch screen HMI.
• Deluxe provides Siemens PLC/HMI, Variable Frequency Drive andcontrolled feed pump, “On-Board” integrated cleaning system, looseship chemical tank and hoses, pH/ORP measurement.
Benefits:
• Four (4) week standard lead time keeps your project moving.
• Compact footprint saves valuable floor space.
• Dry contacts are provided for chemical feed, pretreatment equipment,storage tank levels, and pressure switches.
• With simple utility connections and easy to set up controls, the unit isready for quick on-line service.
173REVERSE OSMOSIS SYSTEMS
Vantage™ M84 Series ROFlow Rates from 100 to 214 gpm
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SYSTEM SPECIFICATIONS
Model Number** M84R024 M84R036 M84R048Product Flow* (gpm)................................ 107 160 214Feed Flow (gpm)...................................... 143 215 285Reject Flow (gpm).................................... 36 53 71
ConnectionsFeed Inlet................................................. 3" 4" 4"Product Outlet.......................................... 3" 3" 4"Reject to Drain Outlet .............................. 2" 2" 2"
MembranesMembrane Size........................................ 8 x 40 8 x 40 8 x 40Membranes/Vessel .................................. 4 4 4Membrane Quantity ................................. 24 36 48VesselsVessel Staging ......................................... 3:2:1 4:3:2 6:4:2
System DimensionsShipping Weight . . . . . . . . . . . .lb 4,550 5,400 6,000
*Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters.**The 8 designates 8" housing, the 4 designates 4 elements in length, and the XXX designates the nominal design product flow rate at 65˚F (18.3˚C).
ORDERING INFORMATION
Catalog Number: M84R 048 E S DM84R . . . . . . . . . . . . . . . . Vantage M84 Series RO 024 - 24 Membranes
036 - 36 Membranes E - Economy
Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 048 - 48 Membranes P - Plus
Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D - Deluxe S - Standard (ILEC) Element
Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C - Cold Water (LE) Element D - 460 VAC, 3 ph, 60 Hz
Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - 575 VAC, 3 ph, 60 Hz
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
174 NANOFILTRATION SYSTEMS
Vantage™ M84 Series NanofiltrationFlow Rates from 100 to 214 gpm
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
GENERAL SYSTEM SPECIFICATIONS
General Electrical: UL, cUL Enclosures NEMA 12 or betterGeneral Control Specs: Economy – Controlled by Microprocessor
Plus – Controlled by Siemens PLC and user friendly touchscreen Human Machine Interface (HMI), Ethernet
Deluxe plus controls plus Variable Frequency Drive (VFD), pH and ORP monitors, Ethernet
Overall Dimensions*: 230” Length, 54” Wide, 90” Height (maximum dimensions)Key Materials of Construction: Painted carbon steel frame, PVC low pressure piping,
stainless steel high pressure pipingMembrane Type: Thin Film Composite nanofiltration membranesAvailable Options: Seismic Zone 4 Anchorage Wet Stamp (CA); pH, ORP, or both
on Economy and Plus Models
Contact a Siemens representative for detailed specifications.
Vantage™ M84 Series packaged single-pass 8-inch nanofiltration units are
designed for industrial and municipal applications requiring high quality
equipment with a fast delivery and a competitive price.
Standard Features:
• Prefilter
• ASME Code Vessels with Pressure Relief
• Three models: Economy, Plus, and Deluxe:
• Economy utilizes rotameters and a microprocessor
• Plus provides more flexibility via control with a Siemens PLC and a user
friendly touch screen HMI.
• Deluxe provides Siemens PLC/HMI, Variable Frequency Drive and
controlled feed pump, “On-Board” integrated cleaning system, loose
ship chemical tank and hoses, pH/ORP measurement.
Benefits:
• Four (4) week standard lead time keeps your project moving.
• Compact footprint saves valuable floor space.
• Dry contacts are provided for chemical feed, pretreatment equipment,
storage tank levels, and pressure switches.
• With simple utility connections and easy to set up controls, the unit is ready
for quick on-line service.
175
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SYSTEM SPECIFICATIONS
Model Number** M84N024 M84N036 M84N048Product Flow* (gpm)................................ 100 150 200Feed Flow (gpm)...................................... 133 200 267Reject Flow (gpm).................................... 33 50 67
ConnectionsFeed Inlet................................................. 3" 4" 4"Product Outlet.......................................... 3" 3" 4"Reject to Drain Outlet .............................. 2" 2" 2"
MembranesMembrane Size........................................ 8 x 40 8 x 40 8 x 40Membranes/Vessel .................................. 4 4 4Membrane Quantity ................................. 24 36 48VesselsVessel Staging ......................................... 3:2:1 4:3:2 6:4:2
System DimensionsShipping Weight . . . . . . . . . . . .lb 4,300 5,150 5,650
*Product flow rates are based on equipment design parameters. These product flow rates may not be appropriate for other feed waters.**The 8 designates 8" housing, the 4 designates 4 elements in length, and the XXX designates the nominal design product flow rate at 65˚F (18.3˚C).
NANOFILTRATION SYSTEMS
Vantage™ M84 Series NanofiltrationFlow Rates from 100 to 214 gpm
ORDERING INFORMATION
Catalog Number: M84N 048 E S DM84N . . . . . . . . . . . . . . . . Vantage M84 Series Nanofilter 024 - 24 Membranes
036 - 36 Membranes E - Economy
Membrane Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 048 - 48 Membranes P - Plus
Package Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D - Deluxe
Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S - Standard (NF) Element D - 460 VAC, 3 ph, 60 Hz
Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E - 575 VAC, 3 ph, 60 Hz
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
176
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
Pharm40 Series RO SystemsFlow Rates from 6 to 24 gpm
SYSTEM SPECIFICATIONS*Model Number Polypropylene*** 67/P43PP-06S/D* 67/P43PP-09S* 67/P43PP-12S* 67/P44PP-16S* 67/P44PP-20S* 67/P44PP-24S*
Model Number Stainless Steel*** 67/P43SS-06S* 67/P43SS-09S* 67/P43SS-12S* 67/P44SS-16S* 67/P44SS-20S* 67/P44SS-24S*
Initial Production Capacity . . . . . . 6 gpm 9 gpm 12 gpm 16 gpm 20 gpm 24 gpmMaximum Recovery . . . . . . . . . . . 75% 75% 75% 75% 75% 75%Vessel Array. . . . . . . . . . . . . . . . . 1:1 1:1:1 2:1:1 2:1:1 2:2:1 3:2:1
System DimensionsH x W x D
inches . . . . . . . . . . . . . . . . . . . 72x30x140 72x30x140 72x30x140 72x30x182 72x30x182 72x30x182cm. . . . . . . . . . . . . . . . . . . . . . 103x76x356 103x76x356 103x76x356 103x76x462 103x76x462 103x76x462
Shipping Weight lb (kg) . . . . . . . . 1,300 (590) 1,400 (636) 1,500 (681) 1,600 (726) 1,700 (772) 1,800 (817)
Electrical RequirementsMotor Service. . . . . . . . . . . . . . . . 480 VAC 480 VAC 480 VAC 480 VAC 480 VAC 480 VACControls Service. . . . . . . . . . . . . . 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC
Membranes**Size . . . . . . . . . . . . . . . . . (inches) 4x40 4x40 4x40 4x40 4x40 4x40Quantity . . . . . . . . . . . . . . . . . . . . 6 9 12 16 20 24
*S - Denotes RO system equipped with Fixed I/O PLC.*D - Denotes RO system equipped with Expandable I/O PLC.
*Capacities are based on a feed water stream of well or softened water. RO projections should be run to calculate actual system performance.**RO membranes are included with each system. ***Sanitary product piping.
Pharm40 Series Reverse Osmosis (RO) Systems were designed for pharmaceutical,biotech and cosmetic applications. These systems can remove from 97 to 99% of salts1.Units are pre-assembled, pre-wired and hydrostatically tested at the factory. Controlsystems are comprised of a control panel and skid-mounted wiring.
• System is mounted on a polyurethane coated structural steel frame
• Product piping is sanitary stainless steel or sanitary polypropylene
• Pump discharge piping is constructed of Schedule 10 butt welded 316L stainless steel
• Product samples valves are located on the outlet of each vessel for quick and easycontrol
• Easy, continuous control through PLC
• Inputs and outputs are installed to communicate with pretreatment/post-treatmentequipment
• Capable of full cleaning and chemical sanitizing for advanced microbial control
• Comprehensive controls and documentation facilitate easy, thorough validationrequirements
1Based on the RO performance projection.
ORDERING INFORMATIONPharm40 Series RO Systems have extensive option packages. For additional product or orderinginformation, please contact Technical Support at 800.875.7873 ext. 5000.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
177
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
40 Series Reverse Osmosis SystemsFlow Rates from 1.8 to 32 gpm
SYSTEM SPECIFICATIONSSeries 41 Series RO Systems 42 Series RO Systems 43 Series RO Systems
Model Number 41-220 41-230 41-240 41-250 42-230 42-240 43-230 43-240
Performance Specifications*Initial Production Capacity . . . . . . . . . 1.8 gpm 2.7 gpm 3.6 gpm 4.5 gpm 5.4 gpm 7.3 gpm 8 gpm 11 gpmVessel Array . . . . . . . . . . . . . . . . . . . . 1:1 1:1:1 1:1:1:1 1:1:1:1:1 1:1:1 1:1:1:1 1:1:1 2:1:1
Membranes†
Size . . . . . . . . . . . . . . . . . . . . (inches) 4x40 4x40 4x40 4x40 4x40 4x40 4x40 4x40Quantity . . . . . . . . . . . . . . . . . . . . . . . 2 3 4 5 6 8 9 12
System DimensionsHxWxD . . . . . . . . . . . . . . . . . . inches 36x30x72 36x30x72 36x30x72 36x30x72 36x30x96 36x30x96 138x30x82 138x30x82. . . . . . . . . . . . . . . . . . . . . . . . . . . . cm 914x762x1829 914x762x1829 914x762x1829 914x762x1829 914x762x2438 914x762x2438 3505x762x2083 3505x762x2083Shipping Weight lb. (kg) . . . . . . . . . . . 500 (227) 550 (249) 600 (272) 650 (295) 1300 (590) 1400 (635) 1500 (681) 1600 (726)
Electrical Requirements High Voltage Service . . . . . . . . . . . . . 480 VAC 3ph – 60 Hz
40 Series Reverse Osmosis (RO) Systems produce from 1.8 to 32.0 gpm of high-puritywater. These systems can remove up to 98% of dissolved inorganics, over 95% of totaldissolved organics and all colloidal and suspended matter larger than 0.05 micron. Theflexible design accommodates virtually all TFC (thin film composite) 4” spiral wound ROmembranes to suit your application.
• Pre-filtration cartridges are included to protect membranes
• Stainless steel pumps and piping resist corrosion
• Sample valves on the feed provide an easy way to test water quality and guaranteesystem performance
• UL Listed enclosure ensures quality and reliability
• Conductivity meter and PLC controller are included
ORDERING INFORMATION
Catalog Number: 67/ XX – XXX – XXSystem Name . . . . . . . . . . 67/ 41 = 1M Vessel 220 = 2 Vessels. . . . . . . . . . . . . . . . . . . . . 42 = 2M Vessel 230 = 3 Vessels. . . . . . . . . . . . . . . . . . . . . 43 = 3M Vessel 240 = 4 Vessels
Series Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 = 4M Vessel 250 = 5 Vessels. . . . . . . . . . . . . . . . . . . . . . . . . . . 260 = 6 Vessels. . . . . . . . . . . . . . . . . . . . . . . . . . . 270 = 7 Vessels
. . . . . . . . . . . . . . . . . . . . . . . . . . . 280 = 8 Vessels XM = No MembranesVessel Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 = 9 Vessels BL = Membranes shipped loose Membrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BN = Membranes installed
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Series (continued) 43 Series RO Systems 44 Series RO Systems
Model Number 43-250 43-260 44-240 44-250 44-260 44-270 44-280 44-290
Performance Specifications*Initial Production Capacity . . . . . . . . . 13 gpm 16 gpm 14 gpm 18 gpm 22 gpm 25 gpm 29 gpm 32 gpmVessel Array . . . . . . . . . . . . . . . . . . . . 2:2:1 3:2:1 2:1:1 2:2:1 3:2:1 3:2:2 4:2:2 4:3:2
Membranes†
Size. . . . . . . . . . . . . . . . . . . . . . . . . . . 4" x 40" 4" x 40" 4" x 40" 4" x 40" 4" x 40" 4" x 40" 4" x 40" 4" x 40"Quantity . . . . . . . . . . . . . . . . . . . . . . . 15 18 16 20 24 28 32 36
System DimensionsHxWxD . . . . . . . . . . . . . . . . . . inches 138x30x82 138x30x82 178x30x82 178x30x82 178x30x82 178x30x82 178x30x82 178x30x82. . . . . . . . . . . . . . . . . . . . . . . . . . . . cm 3505x762x2083 3505x762x2083 4521x762x2083 4521x762x2083 4521x762x2083 4521x762x2083 4521x762x2083 4521x762x2083Shipping Weight lb. (kg) . . . . . . . . . . . 1700 (772) 1800 (817) 1900 (863) 2000 (908) 2100 (953) 2200 (999) 2300 (1044) 2400 (1090)
Electrical Requirements High Voltage Service . . . . . . . . . . . . . 480 VAC 3ph – 60 Hz
†Replacement RO membrane information is available. See catalog index.*Capacities are based on a feed water stream of well or softened water. RO projections should be run to calculate actual system performance.
178
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
Vantage™ M240 Series Two PassReverse Osmosis SystemsFlow Rates from 5 to 20 gpmVantage™ M240 Series Reverse Osmosis (RO) Systems can remove up to 98% of
dissolved inorganics, over 95% of total dissolved organics and all colloidal and suspended
matter larger than 0.05 micron. The flexible design can accommodate virtually all TFC
(thin film composite) 4" spiral wound RO membranes to suit your application.
• Pre-filtration cartridges are included to protect membranes
• Stainless steel pumps and piping resist corrosion
• Sample valves on the feed provide an easy mechanism to test water quality and
guarantee system performance
• UL Listed enclosure ensures quality and reliability
SYSTEM SPECIFICATIONSSeries M243 Series RO Systems M244 Series RO Systems
Model Number M243-250 M243-260 M244-260 M244-280 M244-300Performance Specifications*Initial Production Capacity1 . . . . . . . . . 5 gpm 7.5 gpm 10 gpm 15 gpm 20 gpmVessel Array . . . . . . . . . . . . . . . . . . . . . 1:1:1/1:1 2:1:1/1:1 2:1:1/1:1 2:2:1/2:1 3:2:1/2:1:1
Membranes†
Size . . . . . . . . . . . . . . . . . . . . . (inches) 4x40 4x40 4x40 4x40 4x40Quantity (1st pass/2nd pass) . . . . . . . . 9/6 12/6 16/8 20/12 24/16
System DimensionsHxWxD
inches. . . . . . . . . . . . . . . . . . . . . . 148x40x82 148x40x82 178x40x82 178x40x82 178x40x82cm . . . . . . . . . . . . . . . . . . . . . . . . 3579x1016x2083 3579x1016x2083 4521x1016x2083 4521x1016x2083 4521x1016x2083
Shipping Weight lb. (kg). . . . . . . . . . . . 1800 (817) 1900 (863) 2200 (999) 2400 (1090) 2600 (1180)
Electrical Requirements High Volume Service . . . . . . . . . . . . . 480 VAC 3ph – 60 Hz
†Replacement RO membrane information is available. See catalog index.*Capacities are based on a feed water stream of well or softened water. RO projections should be run to calculate actual systemperformance.
1Inlet water 20 – 75 psig operating at 75 and 90% recovery.
ORDERING INFORMATION
Catalog Number: 67/ XXX – XXX – XX
System Name . . . . . . . . . . . . . 67/ 243 = Two Pass, 4", 3 Membranes/Vessel 250 = 5 VesselsEquipment Product Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 = Two Pass, 4", 4 Membranes/Vessel 260 = 6 Vessels. . . . . . . . . . . . . . . . . . . . . . . . . . 280 = 8 Vessels
Vessel Designation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . 300 = 10 Vessels XM = No MembranesMembrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BL = BW30-4040 shipped loose
OPTION ORDERING INFORMATION
Catalog Number: XpH Monitor = 24/S1001-161 Alarm Beacon = 24/S1001-162
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High Product Pressure Switch = 24/S1001-163
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
179
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
Vantage™ M280 Series Two PassReverse Osmosis SystemsFlow Rates from 25 to 150 gpm
Vantage™ M280 Series Reverse Osmosis (RO) Systems can remove up to 98% ofdissolved inorganics, over 95% of total dissolved organics and all colloidal andsuspended matter larger than 0.05 micron. Their flexible design can accommodatevirtually all TFC (thin film composite) 8" spiral wound RO membranes to suit your application.
• For manufacturing, beverage, microelectronics and boiler feed applications
• Side-port membrane housing reduces maintenance costs
• Pre-filtration cartridges are included to protect membranes
• Stainless steel pumps and piping resist corrosion
• Sample valves on the feed provide an easy mechanism to test water quality andguarantee system performance
• UL Listed enclosure ensures quality and reliability
SYSTEM SPECIFICATIONSSeries M283 Series M284 Series M286 Series
Model Number M283-250 M284-230 M284-260 M284-280 M284-290 M286-280 M286-310 M286-320
Performance Specifications*Initial Production Capacity 25 gpm 25 gpm 50 gpm 60 gpm 75 gpm 100 gpm 125 gpm 150 gpmVessel Array 1:1:1/1:1 1:1/1 2:1:1/1:1 2:2:1/1:1:1 3:2:1/2:1 3:2/2:1 5:2/3:1 5:3/3:1
Membranes†
Size 8" x 40" 8" x 40" 8" x 40" 8" x 40" 8" x 40" 8" x 40" 8" x 40" 8" x 40"Quantity (1st pass/2nd pass) 9/6 8/4 16/8 20/12 24/12 30/18 42/24 48/24
System DimensionsHxWxD inches 166x41x78 201x41x78 201x41x78 196x56x90 196x56x90 277x56x91 277x56x91 277x56x91
cm 4216x1041x1981 5105x1041x1981 5105x1041x1981 4978x1422x2286 4978x1422x2286 7036x1422x2311 7036x1422x2311 7036x1422x2311Shipping Weight lb. (kg) 3000 (1361) 3200 (1453) 3600 (1634) 4000 (1814) 4200 (1907) 7000 (3175) 8500 (3856) 9000 (4082)
Electrical Requirements High Volume Service . . . . . . . . 480 VAC 3ph – 60 Hz
†Replacement RO membrane information is available. See catalog index.*Capacities are based on a feed water stream of well or softened water. RO projections should be run to calculate actual system performance.
ORDERING INFORMATION
Catalog Number: 67/ XX XXX XX
System Number . . . . . . . . 67/ 283 = Two Pass, 8", 3 Membranes/Vessel 230 = 3 Vessels 280 = 8 Vessels284 = Two Pass, 8", 4 Membranes/Vessel 240 = 4 Vessels 290 = 9 Vessels
Equipment Series . . . . . . . . . . . . . . . . . . . . . . . 286 = Two Pass, 8", 6 Membranes/Vessel 250 = 5 Vessels 300 = 10 Vessels260 = 6 Vessels 310 = 11 Vessels
Vessel Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 = 7 Vessels 320 = 12 Vessels XM = No MembranesMembrane Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BL = Membranes shipped loose
OPTION ORDERING INFORMATION
Catalog Number: XpH Monitor = 24/S2001-160
. . . . . . . . . . . . . . . . . . . . . . . Product Water Flush = 24/S2001-161
. . . . . . . . . . . . . . . . . . . . . . . Alarm Beacon = 24/S2001-162
. . . . . . . . . . . . . . . . . . . . . . . High Pump Discharge Pressure Switch = 24/S2001-163. . . . . . . . . . . . . . . . . . . . . . . . . . High Product Pressure Switch = 24/S2001-164Options . . . . . . . . . . . . . . . . . . . . . . Interstage Caustic Injection Pump (Shipped Loose) (call tech support)
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
180
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
BevMAX™ Systems
For Beverage Applications Requiring 50 to 360 gpm
A custom solution with standard products: BevMAX™ standard, pre-packaged
reverse osmosis systems are designed for beverage, drinking water, or other
applications requiring all sanitary stainless steel piping. With ten configurations
available, we can create the system that meets your needs.
BevMAX Systems come with the following items as standard:
• 8" pressure vessels
• Choice of thin film composite (TFC), with three membrane choices — standard
brackish water , low-pressure, or nanofiltration
• Stainless steel multi-stage booster pump
• Programmable logic controller (PLC)
• Butt-welded 316L stainless steel piping
• Conductivity and flow monitors
• Vortex shedding flow meters
Although BevMAX Systems come with standard membrane, piping, pump and
controller choices, you can pick and choose from a wide variety of options to
configure a system that meets your specific needs. Contact your Sales Representative
or our Technical Support Group for more information.
BevMAX™ PRE-PACKAGED UNITS AT-A-GLANCEFeed Product Piping Pump Type Membrane Type Controls Type
Piping
Unit Series Flow Rate Range (gpm)(at default flux rate)
BevMAX . . . . . . . . . . BM Series 75-300 l l l l l
BL Series 90-360 l l l l l
BN Series 50-250 l l l l l
PVC
316L
SST
PVC
316L
SST
Sani
tary
PPL
Sani
tary
316
LSS
T
Vert.
Mul
ti-St
age
Horiz
. Mul
ti-St
age
Subm
ersi
ble
MS
Brac
kish
Wat
er T
FC
(Low
Pre
ssur
e)
Nano
filtra
tion
Fixe
d I/O
PLC
181
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
REVERSE OSMOSIS SYSTEMS
BevMAX™ SystemsFor Beverage Applications Requiring 50 to 360 gpm
SYSTEM SPECIFICATIONSModel Number BL3-18 BL4-28 BL4-40 BL6-54 BL6-72 BM3-18 BM4-28 BM4-40 BM6-54 BM6-72
Product Flow** . . . . . . . . . . . . . 90 gpm 140 gpm 200 gpm 270 gpm 360 gpm 75 gpm 115 gpm 165 gpm 225 gpm 300 gpmFeed Flow. . . . . . . . . . . . . . . . . 120 gpm 187 gpm 267 gpm 360 gpm 480 gpm 100 gpm 153 gpm 220 gpm 300 gpm 400 gpmReject Flow. . . . . . . . . . . . . . . . 30 gpm 47 gpm 67 gpm 90 gpm 125 gpm 25 gpm 38 gpm 55 gpm 75 gpm 100 gpmReject Recycle Flow. . . . . . . . . 5 gpm — — — — 5 gpm — — — —Nominal Recovery . . . . . . . . . . 75% 75% 75% 75% 75% 75% 75% 75% 75% 75%
MembranesMembranes/Vessel . . . . . . . . . . 3 4 4 6 6 3 4 4 6 6Membrane Quantity . . . . . . . . . 18 28 40 54 72 18 28 40 54 72
VesselsVessel Array . . . . . . . . . . . . . . . 3:2:1 4:2:1 5:3:2 6:3 8:4 3:2:1 4:2:1 5:3:2 6:3 8:4Vessel Quantity. . . . . . . . . . . . . 6 7 10 9 12 6 7 10 9 12
System DimensionsHxWxD
inches . . . . . . . . . . . . . . . . . . . . . . 85x44x150 81x55x190 81x55x190 90x60x275 90x60x275 85x44x150 81x55x190 81x55x190 90x60x275 90x60x275cm . . . . . . . . . . . . . . . . . . . . . . . . . 216x112x381 206x140x483 206x140x483 229x152x699 229x152x699 216x112x381 206x140x483 206x140x483 229x152x699 229x152x699
Shipping Weightlb . . . . . . . . . . . . . . . . . . . . . . 2900 3800 4400 7500 9000 2900 3800 4400 7500 9000kg. . . . . . . . . . . . . . . . . . . . . . 1315 1724 1996 3402 4082 1315 1724 1996 3402 4082
Electrical RequirementsControls Service . . . . . . . . . . . . 120V 120V 120V 120V 120V 120V 120V 120V 120V 120VMotor Service . . . . . . . . . . . . . . 480V 480V 480V 480V 480V 480V 480V 480V 480V 480VMotor HP . . . . . . . . . . . . . . . . . 30 40 60 75 100 40 60 75 100 125Amp Draw. . . . . . . . . . . . . . . . . 40 52 77 96 124 52 77 96 124 156
Model Number BN3-12 BN4-24 BN4-40 BN6-48 BN6-60
Product Flow** . . . . . . . . . . . . . 50 gpm 100 gpm 165 gpm 200 gpm 250 gpmFeed Flow. . . . . . . . . . . . . . . . . 67 gpm 133 gpm 220 gpm 207 gpm 333 gpmReject Flow. . . . . . . . . . . . . . . . 17 gpm 33 gpm 55 gpm 67 gpm 83 gpmReject Recycle Flow. . . . . . . . . 5 gpm — — — —Nominal Recovery . . . . . . . . . . 75% 75% 75% 75% 75%
MembranesMembranes/Vessel . . . . . . . . . . 3 4 4 6 6Membrane Quantity . . . . . . . . . 12 24 40 48 60
VesselsVessel Array . . . . . . . . . . . . . . . 2:1:1 4:2:1 5:3:2 5:3 6:4Vessel Quantity. . . . . . . . . . . . . 4 7 10 8 10
System DimensionsHxWxD
inches . . . . . . . . . . . . . . . . . . . . . . 85x44x150 81x55x190 81x55x190 90x60x275 90x60x275cm . . . . . . . . . . . . . . . . . . . . . . . . . 216x112x381 206x140x483 206x140x483 229x152x699 229x152x699
Shipping Weightlb . . . . . . . . . . . . . . . . . . . . . . 4400 7500 7500 9000 9000kg. . . . . . . . . . . . . . . . . . . . . . 1996 3402 3402 4082 4082
Electrical RequirementsControls Service . . . . . . . . . . . . 120V 120V 120V 120V 120VMotor Service . . . . . . . . . . . . . . 480V 480V 480V 480V 480VMotor HP . . . . . . . . . . . . . . . . . 10 20 25 30 40Amp Draw. . . . . . . . . . . . . . . . . 14 27 34 40 52
**Product flow rates are based on 16-17 GFD flux rates for well water feed. These product flow rates may not be appropriate for other feed waters. An application specialist can de-rate the units for other feed water conditions.
Due to different feed flow requirements and membrane type, the cartridge filter housings must be sized and ordered separately.
182
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SERVICE DEIONIZATION (SDI)
Service Deionization (SDI) Systems
Service Deionization (SDI) from Siemens is a convenient and economical way to
produce high-purity water from potable feed water. SDI systems consist of activated
carbon and ion-exchange resin contained in portable tanks, custom-designed and
configured to meet your water purity requirements, flow rates and budget. With SDI
systems, you don’t have to make a major capital investment, handle chemicals or
maintain equipment — our technically trained service representatives handle tank
delivery, installation and maintenance.
Siemens offers SDI systems and resins that have been regenerated in our GMP (Good
Manufacturing Practices) facility to ensure stringent quality control for critical
pharmaceutical and dialysis applications.
Resin, a Grade for Every Application
Industrial-grade systems produce greater than 14 megohm-cm quality water, are
extremely durable and can be operated at flow rates up to 150 gallons per minute or
higher when multiple systems are placed in parallel. They are especially well suited
for applications where large resin capacities are required.
Premium-grade systems are designed for high-quality applications requiring up to
18 megohm-cm water quality. Filled with Type I or Type II resin, these systems meet
CAP Type I and NCCLS Type I specifications for clinical applications. Our premium-
grade resin manufacturing process is fully batch controlled to ensure consistent
quality.
Ultra-grade, QSR Compliant
Ultra-grade systems are designed for critical laboratory, medical, dialysis and
pharmaceutical applications. These systems deliver up to 18 megohm-cm water
quality with superior silica removal and significantly lower TOC levels. Our ultra-
grade resin manufacturing and regeneration processes are fully documented and
batch controlled, in compliance with good manufacturing practices and quality
system regulations.
183
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SERVICE DEIONIZATION (SDI)
Service Deionization (SDI) Systems
Quality System Requirements (QSR)
Mixed bed deionizers are specifically processed under QSR requirements in an FDA
registered facility as a medical device for hemodialysis and ultra pure laboratory
applications. These resins are controlled for not only ionic contaminant removal but also
for reduced bacterial and endotoxin limitations. Each regenerated service unit is tested
for pressure integrity and product water quality before it is installed in your plant.
Quality Tested Before it Reaches You
Quality Control
Incoming QC: Raw materials must meet quality specifications.
In-Process QC: Each component has its own operating criteria, and the entire process is
monitored.
Final Product QC: Materials are double-checked for quality with results recorded in the batch
record.
Disinfection
Each service unit is chemically disinfected before refilling.
Document Control
We have a comprehensive document control system. No process changes are made
without proper notification and approval.
Tank Traceability
The serial number of each service unit is recorded on the production control log, so total
traceability is ensured.
184
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SERVICE DEIONIZATION (SDI)
Service Deionization (SDI) Systems
Choose from a Wide Range of Deionizers and Carbons
Cation-bed Deionizers have a high capacity for removing positively charged
dissolved ionic contaminants such as calcium, sodium, magnesium, potassium, iron
and manganese. The durable gel resins provide stability against osmotic, thermal and
impact shock.
Anion-bed Deionizers have a high capacity for removing negatively charged
dissolved ionic contaminants such as carbonate, bicarbonates, sulfates, chlorides,
nitrates and silica. The durable gel resins used are stable against osmotic, thermal
and impact shock. A variety of anion resins are available, suitable for virtually any
water application.
Mixed-bed Deionizers provide higher quality, and a more neutral pH than separate
bed systems as well as enhanced silica and CO2 removal. Our units are guaranteed to
produce the quality of water required for any removal application, up to 18 megohm-
cm resistivity at 25°C. In-line quality monitors immediately alert users when resin
tanks need to be changed.
Ultra Mixed-bed Deionizers provide superior silica removal and significantly lower
TOC levels. Ideal for microelectronics and pharmaceutical applications where stricter
controls of critical contaminants are required.
Macroporous Organic Scavenger Resins offer extra-large internal surface areas and
can therefore provide higher adsorption of dissolved and undissolved organic
contaminants. The strongly basic anion resins will remove not only those organic
ions normally removed by standard anion exchange, but those that would normally
pass right through most demineralizers.
Colloidal Scavenging Deionizers have a high capacity for removing inorganic and
organic anions. The durable, macroporous resins are extremely resistant to organic
fouling, and efficiently remove colloids.
Activated Carbon Units remove chlorine and some dissolved organic contaminants.
Each replacement carbon unit contains virgin carbon to assure maximum water
quality and service life of the bed.
GMP Tanks for dialysis and validated processes are also available.
ORDERING INFORMATION
SDI is flexible and can be customized to meet your needs. Contact Technical Support at (800) 875-7873, ext. 5000 to discuss your requirements and set-up a site visit and water analysis.
185
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SOFTENERS
KF Series SoftenersFlow Rates from 3 to 275 gpm
KF Series Water Softeners are lightweight, with corrosion-resistant FRP pressure vessel
and cost-effective top mounted valve for commercial and light industrial applications.
• Fiberglass tanks are durable and corrosion-free
• Tank liners are blow-molded plastic wrapped in high-strength fiberglass and have
epoxy resin for worry-free service
• Softeners include a motorized, 5-cycle control valve that is quiet, efficient and
dependable
• Automatic regeneration controller is an electromechanical timer
• Duplex systems are available for applications that require a continuous supply
of softened water
• Pretreatment lock-out switch assembly is included to deactivate downstream
equipment during regeneration
SYSTEM SPECIFICATIONS
Series KFZSS
ApplicationTank Size Pipe Commercial* RO-Feed** Backwash Capacity at Media Overall Shipping Salt(DxH in) Size Service Service Flow 15 lbs./CF Vol. Dimensions Weight Storage
(in) Flow Flow (Grains in 000's) (ft3) LxDxH (in) lb. (kg) lb. (kg)
9x40 1.0 19 gpm 3 gpm 2 gpm 30 1 33x20x50 160 (73) 350 (159)12x52 1.0, 1.5 39 gpm 6 gpm 3.5 gpm 60 2 36x20x66 300 (136) 350 (159)14x65 1.0, 1.5 42 gpm 9 gpm 5 gpm 90 3 44x24x79 450 (204) 700 (318) 16x65 1.0, 1.5 46 gpm 12 gpm 7 gpm 120 4 46x24x79 530 (240) 700 (318)18x65 1.5, 2.0 81 gpm 15 gpm 9 gpm 150 5 50x24x80 730 (331) 700 (318) 21x62 1.5, 2.0 77 gpm 21 gpm 12 gpm 210 7 50x24x80 900 (408) 700 (318)24x72 1.5, 2.0 91 gpm 30 gpm 15 gpm 300 10 60x30x89 1860 (843) 1000 (454)30x72 2.0, 3.0 105 gpm 45 gpm 25 gpm 450 15 66x40x92 1940 (880) 1000 (454)36x72 3.0 250 gpm 60 gpm 35 gpm 600 20 88x40x100 2460 (1116) 1800 (817)42x72 3.0 268 gpm 75 gpm 50 gpm 750 25 105x50x112 2880 (1306) 3700 (1679)48x72 3.0 275 gpm 120 gpm 70 gpm 1200 40 111x50x112 3660 (1660) 3700 (1679)
Electrical Requirements 115V/1 ph /60 Hz – 10 watts
*Flow is based on a differential pressure of <25 psid. Capacity is based on 10 gpg total hardness as CaCO3 that is free of color, oil and turbidity, andregeneration is at 15 lbs. NaCl/ft3.
**Maximum (RO Pretreatment) flow rate calculated at 3 gpm/ft3
ORDERING INFORMATION
PZV
Catalog Number: KFZSS XXX F XZF X X
Description . . . . . . . . . . . . . . KFZSS - Single 009, 012, 014,016, 018, 021,024, 030, 036,
Pressure Vessel Diameter . . . . . . . . . . . . . . . . 042, 048F = Non-Code
Pressure Vessel Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fiberglass A = 1.0"XZF = NEMA 3R Equivalent 7-day Timelock B = 1.5"
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PZV = NEMA 3R Equivalent Volume Initiation C = 2.0" Inlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E = 3.0" X = No Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Option
Not all pipe sizes are available on the standard units, please use the specifications for standard sizes.
To determine your order number, replace the X with one of the numbered options below it.†All sizes are not available with every size.
Requires field assembly.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
186
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SOFTENERS
KF Series Duplex Alternating SoftenersFlow Rates from 3 to 275 gpm
KF Series Duplex Alternating Water Softeners are lightweight, with corrosion-
resistant FRP pressure vessel, and cost-effective top-mounted valve for
commercial and light industrial applications.
• Fiberglass tanks are durable and corrosion-free
• Tank liners are blow-molded plastic wrapped in high-strength fiberglass and
units have epoxy resin for worry-free service
• Softeners include two motorized, 5-cycle control valves that are quiet,
efficient and dependable
• Automatic regeneration controller with volume initiation facilitates operation
• Maintains flow at all times. One unit is operating while second unit
regenerates and is then in standby
SYSTEM SPECIFICATIONS
Series KFZSD ApplicationTank Size Pipe Commercial* RO-Feed** Backwash Capacity at Media Shipping Brine Tank Size(D x H) Size Service Service Flow 15 lbs./CF Vol. Weight D x H(inch) (in.) Flow Flow (Grains in 000's) (ft3) lb. (kg) inch (cm)
Electrical Requirements . . . . . . . . . . . . . . . . . . . 115 V/1 ph/60 Hz – 10 watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*Flow is based on a differential pressure of <25 psid. Capacity is based on 10 gpg total hardness as CaCO3 that is free of color, oil and turbidity and regeneration is at 15 lbs. NaCl/ft3.**Maximum (RO Pretreatment) flow rate calculated at 3 gpm/ft3
ORDERING INFORMATION
Catalog Number: KFZSD XXX F P Z V X X
Description . . . . . . . . . . . . . . . . . . KFZSD - Duplex 009, 012, 014016, 018, 021
Pressure Vessel Diameter . . . . . . . . . . . . . . . . . . . . . . 024, 030, 036042, 048
F = Non-Code P = NEMA3RPressure Vessel Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fiberglass EquivalentControl Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . with electronic controlsLevel of Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z = Stand Alone V = Vol. Initiated Alternating A= 1”
with Totalizer B = 1.5" Backwash/Regeneration Initiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (with electronic controls) C = 2.0" Inlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E = 3.0" Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. X = No Option
To determine your catalog order number, replace the X with one of the numbered options below it.†All sizes are not available with every tank size.
9 x 40 12 x 5214 x 6516 x 65 18 x 6521 x 6224 x 7230 x 7236 x 7242 x 7248 x 72
11, 1.51, 1.51, 1.51.5, 21.5, 21.5, 22, 3
333
19 gpm39 gpm42 gpm46 gpm81 gpm77 gpm91 gpm213 gpm250 gpm268 gpm275 gpm
3 gpm6 gpm9 gpm12 gpm15 gpm21 gpm30 gpm45 gpm60 gpm75 gpm120 gpm
2 gpm3.5 gpm5 gpm7 gpm9 gpm12 gpm15 gpm25 gpm35 gpm48 gpm63 gpm
3060901201502103004506007501200
1234571015202540
270 (123)500 (227)750 (341)880 (400)
1,220 (554)1,500 (681)
3,100 (1,407)3,240 (1,470)4,100 (1,860)4,800 (2,178)6,100 (2,767)
18x40 (46x102)18x40 (46x102)24x50 (61x127)24x50 (61x127)24x50 (61x127)24x50 (61x127)24x50 (61x127)30x48 (77x122)39x48 (100x122)50x60 (127x153)50x60 (127x153)
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Requires field assembly.
187
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SOFTENERS
KF Series Twin Alternating SoftenersFlow Rates from 1.5 to 68 gpm
KF Series Twin Alternating Water Softeners are lightweight, with corrosion-resistantFRP pressure vessel, and cost-effective top mounted valve for commercial and lightindustrial applications.
• Fiberglass tanks are durable and corrosion-free
• Tank liners are blow-molded plastic wrapped in high-strength fiberglass and unitshave epoxy resin for worry-free service
• Softeners include a single motorized, 5-cycle control valve that is quiet, efficientand dependable
• Automatic regeneration controller with volume initiation facilitates operation
• Pretreatment lock-out switch assembly is included to deactivate downstreamequipment during regeneration
SYSTEM SPECIFICATIONS
Series KFZST ApplicationTank Size Pipe Commercial* RO-Feed** Backwash Capacity at Media Overall Shipping Salt(DxH in) Size Service Service Flow 15 lb./CF Vol. Dimensions Weight Storage
(in) Flow Flow (Grains in 000's) (ft3) LxDxH (in) lb. (kg) lb. (kg)
7x44 1.0 15 gpm 1.5 gpm 1.5 gpm 15 0.5 33x18x53 120 (55) 350 (159)9x40 1.0 19 gpm 3 gpm 2 gpm 30 1 33x20x49 190 (86) 350 (159)10x54 1.0 18 gpm 4.5 gpm 3 gpm 45 1.5 34x20x63 250 (114) 350 (159)12x52 1.0, 1.5 39 gpm 6 gpm 3.5 gpm 60 2 36x20x62 310 (141) 350 (159)14x65 1.0, 1.5 42 gpm 9 gpm 5 gpm 90 3 44x24x75 550 (250) 700 (318) 16x65 1.0, 1.5 46 gpm 12 gpm 7 gpm 120 4 46x24x75 700 (318) 700 (318)18x65 1.5 54 gpm 15 gpm 9 gpm 150 5 50x24x75 1050 (476) 700 (318)21x62 1.5 52 gpm 21 gpm 12 gpm 210 7 50x24x80 1220 (553) 700 (318)24x72 1.5 68 gpm 30 gpm 15 gpm 300 10 60x30x88 1610 (730) 1000 (454)
Electrical Requirements . . . . . . . . . . . . . 115 V/1 ph /60 Hz – 10 watts
*Flow is based on a differential pressure of <25 psid. Capacity is based on 10 gpg total hardness as CaCO3 that is free of color, oil and turbidity, and regeneration is at15 lbs. NaCl/ft3.
**Maximum (RO Pretreatment) flow rate calculated at 3 gpm/ft3
ORDERING INFORMATION
Catalog Number: KFZST XXX F X Z N X X
Description . . . . . . . . . . . . . . . . . . KFZST - Twin 007, 009, 010,. . . . . . . . . . . . . . . . . . . . . . . . . . . . 012, 014, 016, Pressure Vessel Diameter . . . . . . . . . . . . . . . . . . . . . . 018, 021, 024,
F = Non-Code Pressure Vessel Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FiberglassControl Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P = NEMA3R EquivalentLevel of Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z = Stand Alone
N = Volume Initiated; Single MeterBackwash/Regeneration Initiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . w/Lock-Out (electromechanical) A= 1.0" Inlet/Outlet Pipe Size† . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B = 1.5" X = NoOptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Option
To determine your catalog order number, replace the X with one of the numbered options below it.†All sizes are not available with every tank size.
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
Requires field assembly.
188
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SOFTENERS
VP Series SoftenersFlow Rates from 20 to 420 gpm
VP Series Softeners are a low cost, reliable and efficient way to purify water. These
rugged, pre-engineered, pre-assembled units minimize installation and start-up costs
and are ideal for boiler feed, process water or rinse water applications.
• VPES denotes Non-ASME code vessels offered with express delivery
• VPAS denotes ASME code vessels with stamp available
• Simple design maximizes reliability and efficiency
• 100 psig vessel rating offers added strength and integrity
• Structural steel legs (seismic zone 4) provide rigid support of vessel for safety
• Skid mount (seismic zone 4) with structural steel beams for duplex systems
• Backwash and regeneration controls are highly reliable
• Optional metallic piping ensures long life and durability
• Standard epoxy internal and external coating extends vessel life
SYSTEM SPECIFICATIONS
Model Number VPES/VPAS-024 VPES/VPAS-030 VPES/VPAS-630 VPES/VPAS-636 VPES/VPAS-736Flow Rates
Good 50 70 105 140 175Better 35 50 75 100 125Best 20 30 45 60 75
Backwash Flow Rate 17 27 27 39 39Media (cubic feet) 7 10 15 20 25Capacity, Kgr CaCO3 (15 lb./CF) 210 300 450 600 750System Dimensions*Pipe Size 1-1/2” 2” 2-1/2” 2-1/2” 3”Column Size (D x H)
inch 24x48 30x48 30x60 36x60 36x72cm 61x122 77x122 77x153 92x153 92x183
Brine Tank Size - inch 24x48 30x60 30x60 48x48 52x60*H x W x D Simplex - inch 76x41x41 78x43x48 90x51x47 96x51x57 108x55x58
(Duplex) - inch (80x97x41) (82x97x48) (100x97x60) (100x97x60) (112x97x60)Simplex - cm 193x104x104 198x109x122 229x130x119 244x130x145 274x140x147 (Duplex) - cm (204x264x104) (209x277x122) (254x246x152) (254x246x152) (284x246x152)
Shipping Weightlb. – Simplex (Duplex) 1,100 (2,260) 1,540 (3,080) 1,890 (3,780) 2,680 (5,360) 3,050 (6,100)kg – Simplex (Duplex) 499 (1,026) 699 (1,398) 858 (1,715) 1,216 (2,432) 1,384 (2,767)
Operating Weightlb. – Simplex (Duplex) 1,930 (3,860) 2,740 (5,480) 3,390 (6,780) 4,870 (9,740) 5,590 (11,180)kg – Simplex (Duplex) 876 (1,751) 1,243 (2,486) 1,538 (3,076) 2,209 (4,418) 2,536 (5,072)
Electrical Requirements 110 V / 60 Hz / 1 ph / 3 watts
*Approximate**Rating for metallic piping only. Plastic piping requires aeration due to line velocities.
189
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SYSTEM SPECIFICATIONS
Model Number VPES/VPAS-742 VPES/VPAS-748 VPES/VPAS-754 VPES/VPAS-760 VPES/VPAS-772Flow Rates
Good 245 280 350 420** N/ABetter 175 200 250 300 500**Best 105 120 150 180 300
Backwash Flow Rate 53 69 87 108 156Media (cubic feet) 30 40 50 60 100Capacity, Kgr CaCO3 (15 lb./CF) 900 1,200 1,500 1,800 3,000System Dimensions*Pipe Size 3” 4” 4” 4” 4”Column Size (D x H)
inch (cm) 42x72 (107x183) 48x72 (122x183) 54x72 (139x183) 60x72 (153x183) 72x72 (183x183)Brine Tank Size, inch 52x60 52x60 55x70 55x70 69x84*H x W x D Simplex - inch 112x55x63 118x62x76 121x65x82 125x70x88 129x79x100
(Duplex) - inch (116x132x71) (122x133x76) (123x158x82) (128x158x97) (131x158x100)Simplex - cm 284x140x160 300x157x193 307x165x208 318x178x224 328x201x254
(Duplex) - cm (295x335x180) (310x338x193) (312x401x208) (325x401x246) (333x401x254)Shipping Weight
lb.– Simplex (Duplex) 4,070 (8,140) 5,300 (10,600) 7,070 (14,140) 8,550 (17,100) 13,350 (26,700)kg – Simplex (Duplex) 1,847 (3,693) 2,405 (4,809) 3,207 (6,414) 3,879 (7,757) 6,056 (12,111)
Operating Weightlb. – Simplex (Duplex) 7,590 (15,180) 9,880 (19,760) 12,980 (25,960) 15,830 (31,660) 24,130 (48,260)kg – Simplex (Duplex) 3,443 (6,886) 4,482 (8,963) 5,888 (11,776) 7,181 (14,361) 10,946 (21,891)
Electrical Requirements 110 V / 60 Hz / 1 ph / 3 watts*Approximate**Rating for metallic piping only. Plastic piping requires aeration due to line velocities.
ORDERING INFORMATIONVP Series Softeners have extensive option packages. For ordering instructions, or additionalproduct information, please contact technical support at 800.875.7873 extension 5000.
In accordance with Siemens policy for continual product development andimprovements, we reserve the right to change the product informationwithin this literature at any time, without notice.
SOFTENERS
VP Series SoftenersFlow Rates from 20 to 420 gpm
190
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
STORAGE TANKS
Storage, Polyethylene, Conical-bottom, Gasket Lid w/Stand
The conical bottom polyethylene storage tank (55 to 2,000 gallons) insures
complete tank drainage for cleaning and sanitization operations. The tank is
constructed of virgin high-density FDA approved polyethylene and supported by
a structural steel stand painted with an acid resistant epoxy.
• Each tank includes seven factory installed polyethylene half coupling fittings
welded and tapered into the tank wall
• Polyethylene tank lid with neoprene flat gasket seal is bolted to the tank for air
tight access to the tank interior
• 3-position level controller, hydrophobic vent filter, nitrogen blanket system and
vacuum/pressure relief valve optional
SYSTEM SPECIFICATIONS*Catalog Number TPCC00055 TPCC00100 TPCC00200 TPCC00250 TPCC00350 TPCC00500 TPCC00750 TPCC01000
Tank Volume (gallons) . . . . . . . . 55 100 200 250 350 500 750 1000Construction Materials . . . . . . . . Virgin, high-density polyethylene that is FDA approved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum Service Temp. . . . . . . Rated to 160°F (70°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System DimensionsDia. (D) x Overall Height (E) (inches) 28x64 32x59 35x86 45x68 46x88 57x86 68x88 72x104Wall Thickness . . . . . . . . . . . . . . 3/16" 1/4" 1/4" 5/16" 5/16" 3/8" 3/8" 3/8"
Shipping WeightIndustrial (lbs.) . . . . . . . . . . . . . . 75 160 200 250 350 425 540 640
Fittings (factory installed)Fill Fitting . . . . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1.5"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFReturn Fitting . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1.5"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFOverflow Fitting . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1.5"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFOutlet Fitting. . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1.5"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFVent Fitting . . . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTFLevel/Sight Fittings. . . . . . . . . . . two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF
Catalog Number TPCC01500 TPCC02000
Tank Volume (gallons) . . . . . . . . 1500 2000Construction Materials . . . . . . . . Virgin, high-density polyethylene
that is FDA approvedMaximum Service Temp. . . . . . . Rated to 160°F (70°C)
System DimensionsD x H (inches) . . . . . . . . . . . . . . 79x99 86x103Wall Thickness . . . . . . . . . . . . . . 7/16" 7/16"
Shipping WeightIndustrial (lbs.) . . . . . . . . . . . . . . 875 1025
Fittings (factory installed)Fill Fitting . . . . . . . . . . . . . . . . . . one-2"NPTF one-2"NPTFReturn Fitting . . . . . . . . . . . . . . . one-2"NPTF one-2"NPTFOverflow Fitting . . . . . . . . . . . . . one-2"NPTF one-2"NPTFOutlet Fitting. . . . . . . . . . . . . . . . one-2"NPTF one-2"NPTFVent Fitting . . . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTFLevel/Sight Fittings. . . . . . . . . . . two-.5" NPTF two-.5" NPTF
*Please contact Technical Support to obtain a drawing with exact fitting locations
191
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
STORAGE TANKS
Storage, Fiberglass, Dish-bottom, Closed Top w/Skirt
Constructed from premium, non-pigmented resin, which meets FDA regulations
for food handling, each tank is shipped with one welded outlet siphon valve
fitting, one 1/2" welded half coupling, one overflow welded half coupling and
four bulkhead fittings.
SYSTEM SPECIFICATIONS*Catalog Number TFDC0014A TFDC0024A TFDC0034A TFDC0045A TFDC0059A TFDC0073A TFDC0087A
Tank Volume (gallons) . . . . . . . . 145 245 345 445 590 735 875Construction Materials . . . . . . . . Non-pigmented premium resin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System DimensionsD x H (inches) . . . . . . . . . . . . . . 30x62 32x85 38x85 42x89 48x92 48x110 48x129Wall Thickness . . . . . . . . . . . . . . 5/32" 5/32" 7/32" 7/32" 7/32" 7/32" 7/32"
Shipping WeightIndustrial (lbs.) . . . . . . . . . . . . . . 74 96 154 161 211 263 285
FittingsFill Fitting . . . . . . . . . . . . . . . . . . one-1" one-1" one-1.5" one-1.5" one-2" one-2" one-2"Return Fitting . . . . . . . . . . . . . . . one-1" one-1" one-1.5" one-1.5" one-2" one-2" one-2"Overflow Fitting . . . . . . . . . . . . . one-1" one-1" one-1.5" one-1.5" one-2" one-2" one-2"Outlet Fitting. . . . . . . . . . . . . . . . one-1" one-1" one-1.5" one-1.5" one-2" one-2" one-2"Vent Fitting . . . . . . . . . . . . . . . . . one-1" one-1" one-1" one-1" one-1" one-1" one-1"
Catalog Number TFDC0102A TFDC0151A TFDC0200A TFDC0250A
Tank Volume (gallons) . . . . . . . . 1020 1515 2000 2500Construction Materials . . . . . . . . Non-pigmented premium resin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System DimensionsD x H (inches) . . . . . . . . . . . . . . 60x101 60x143 90x90 72x172Wall Thickness . . . . . . . . . . . . . . 5/32" 5/32" 3/16" 7/32"
Shipping WeightIndustrial (lbs.) . . . . . . . . . . . . . . 474 567 1290 820
FittingsFill Fitting . . . . . . . . . . . . . . . . . . one-2" one-2" one-2" one-2"Return Fitting . . . . . . . . . . . . . . . one-2" one-2" one-2" one-2"Overflow Fitting . . . . . . . . . . . . . one-2" one-2" one-2" one-2"Outlet Fitting. . . . . . . . . . . . . . . . one-2" one-2" one-2" one-3"Vent Fitting . . . . . . . . . . . . . . . . . one-1" one-1" one-1" one-1.5"
*Please contact Technical Support to obtain a drawing with exact fitting locations
192
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
STORAGE TANKS
Storage, Polyethylene, Flat-bottom, Domed Top
Siemens flat bottom polyethylene storage tank (55 to 6,500 gallons) has a closed
cover design with a siphon valve fitting at the tank bottom for maximum
drainage. The seamless one piece construction is fabricated from FDA approved
virgin high density polyethylene.
• Each tank includes seven factory installed polyethylene half coupling fittings
welded and tapered into the tank wall
• Fume tight gasketed handway or manway is mounted on the top of the closed
tank to provide access to the interior
• 3-position level controller, hydrophobic vent filter, nitrogen blanket system and
vacuum/pressure relief valve optional
SYSTEM SPECIFICATIONS*Catalog Number TPFC00055 TPFC00110 TPFC00165 TPFC00220 TPFC00300 TPFC00500 TPFC00750 TPFC01000
Tank Volume (gallons) . . . . . . . . 55 110 165 220 300 500 750 1000Construction Materials . . . . . . . . Virgin, high-density polyethylene that is FDA approved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum Service Temp . . . . . . . Rated to 160°F (70°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System DimensionsD x H (inches) . . . . . . . . . . . . . . 20x38 35x36 31x58 35x63 35x81 46x76 46x119 64x81Wall Thickness . . . . . . . . . . . . . . 3/16" 3/16" 3/16" 3/16" 3/16" 1/4" 1/4" 1/4"
Shipping WeightIndustrial (lbs.) . . . . . . . . . . . . . . 25 45 50 70 90 120 200 220
Fittings (factory installed)Fill Fitting . . . . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1.5"NPTF one-1.5"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFReturn Fitting . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1.5"NPTF one-1.5"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFOverflow Fitting . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1.5"NPTF one-1.5"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFOutlet Fitting. . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1.5"NPTF one-1.5"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFVent Fitting . . . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTF one-1"NPTFLevel/Sight Fittings. . . . . . . . . . . two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTFHandway . . . . . . . . . . . . . . . . . . one-8" one-5" one-8" one-5" one-16" one-16" one-16" one-16"
Catalog Number TPFC01500 TPFC02000 TPFC02500 TPFC03000 TPFC03600 TPFC04000 TPFC05000 TPFC06500
Tank Volume (gallons) . . . . . . . . 1500 2000 2500 3000 3600 4000 5000 6500Construction Materials . . . . . . . . Virgin, high-density polyethylene that is FDA approved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum Service Temp . . . . . . . Rated to 160°F (70°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System DimensionsD x H (inches) . . . . . . . . . . . . . . 64x121 64x144 95x89 95x105 86x156 95x140 120x151 120x144Wall Thickness . . . . . . . . . . . . . . 3/8" 3/8" 3/8" 7/8" 7/8" 1/2" 1/2" 7/8"
Shipping WeightIndustrial (lbs.) . . . . . . . . . . . . . . 365 525 550 660 1050 1100 1400 1600
Fittings (factory installed)Fill Fitting . . . . . . . . . . . . . . . . . . one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFReturn Fitting . . . . . . . . . . . . . . . one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFOverflow Fitting . . . . . . . . . . . . . one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTF one-2"NPTFOutlet Fitting. . . . . . . . . . . . . . . . one-2"NPTF one-2"NPTF one-2"NPTF one-3"NPTF one-3"NPTF one-3"NPTF one-3"NPTF one-3"NPTFVent Fitting . . . . . . . . . . . . . . . . . one-1"NPTF one-1"NPTF one-1"NPTF one-1.5"NPTF one-1.5"NPTF one-1.5"NPTF one-1.5"NPTF one-1.5"NPTFLevel/Sight Fittings. . . . . . . . . . . two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTF two-.5" NPTFHandway . . . . . . . . . . . . . . . . . . one-8" one-16" one-16" one-16" one-16" one-16" one-16" one-16"
*Please contact Technical Support to obtain a drawing with exact fitting locations
193
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
Terrapure® Storage Tanks are designed for the purest process water or chemistries.
They have a one-piece capsule design that provides for complete drainage.
• Viton®-gasketed 6" screw lid maintains nitrogen blanket pressure
• Supplied with six unique “no-profile” fittings ensure that there are no internal tank
protrusions to collect particles, and no crevices, welds or seams to support microbial
growth
• Totally enclosed, one-piece rotationally molded construction yields a rugged,
seamless, corrosion-free container suitable for an almost unlimited number of
solution, storage and dispensing applications
• All-plastic pedestal molded entirely of LPE (no metal reinforcement), capable of
supporting loads up to 4000 lb.
• Convenient “mousehole” provides easy access to the bottom center fitting
• Only 34" in diameter to fit through standard doors
• Can be steam cleaned (up to 190°F) and features materials that comply with FDA
regulations
STORAGE TANKS
Terrapure®1,2 Storage Tanks
SYSTEM SPECIFICATIONS*
Catalog Number TPPBWF125 TPSBWF125 TPPBWF250 TPSBWF250
Capacitygallons. . . . . . . . . . . . . . . . 125 125 250 250
Base Material . . . . . . . . . . . . . . . Plastic Steel Plastic Steel
System DimensionsA. . . . . . . . . . . . . . . . . . . . . . . . . 44" 44" 81" 81"B. . . . . . . . . . . . . . . . . . . . . . . . . 61" 67" 96" 104"C. . . . . . . . . . . . . . . . . . . . . . . . . 5/16" 5/16" 5/16" 5/16"
Shipping WeightTank (lbs.) . . . . . . . . . . . . . . . . . 50 50 81 81Pedestal (lbs.) . . . . . . . . . . . . . . 68 100 68 100*Please contact Technical Support to obtain a drawing with exact fitting locations1 Tank must be vented to atmosphere at all times2 Food grade construction complies with FDA regulations
1: 6" Viton® gasketed screw cap2: Painted Carbon Steel Stand3: Molded-in fitting flats (typical 8 places)
194
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SYSTEM, EPV™ VALIDATABLE SKIDDED
EPV™ High Purity Water SystemsFlow Rates from 0.1 to 50 gpm
Siemens has developed a comprehensive water system product line tailored to clients
requiring validation level documentation. The Economical, Pre-Packaged, Validatable
High Purity Water Systems offer a complete water system package that meets the most
common quantity and quality requirements of the Laboratory, Medical, and BioPharm
markets.
Whatever level of water quality you require, there’s an EPV™ System to meet your
needs. Designed to produce flow rates from 0.1 to 50 gallons per minute (gpm), at the
point of use, these integrated, skid-mounted systems include pretreatment, make-up
water, storage and distribution equipment - everything you need to ensure a reliable,
cost-effective, supply of high-purity water, all with validation level documentation.
Standard Features:
• Developed for laboratory, biotechnology and pharmaceutical applications
• Multiple configurations including: Service DI, Non-recirculating Pretreatment,
Continuous Recirculating Pretreatment, and Hot Water Sanitizable
• Easy installation / skid mounted
• Complete documentation package including O&M with installation, start-up and
operation procedures, P&ID, Electrical Schematics, Installation and Operational
Qualification Verification Data Sheets, and Quality Assurance data reports
• Optional documentation includes: Dry Factory Acceptance Test, Wet Factory
Acceptance Test, Installation Protocol, Operational Protocol, and Performance
Qualification Protocol
Benefits:
• Fast delivery with pre-manufactured systems
• UL and Seismic Zone 4 compliance to meet regional permitting regulations
• Meets or exceeds the following water quality requirements: USP Purified Water, CAP I,
ASTM I, 18.2 megohm-cm resistivity
• Validation Assistance available for execution of the
Installation/Operational/Performance Qualifications
195
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SYSTEM, EPV™ VALIDATABLE SKIDDED
EPV™ Systems
196
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SYSTEM, PreVUE® AND APEX™ VALIDATED SKIDDED
PreVUE® and APEX™ SystemsModular USP Purified Water Generation
Seven sizes—nominal flow rates range from 2 to 25 gpm. The PreVUE® and APEX™
systems are pre-engineered, totally integrated and automated biopharmaceutical
water purification systems. These characteristics help you expedite all phases of
planning, procuring and commissioning a new water purification system.
Pre-Engineered
• Prompt drawing submittals speed construction and planning
• Quick delivery keeps project moving fast
• cGMP design & construction assures quality Validation
• Fully functional wet FAT reduces start-up time
• Easily understood GAMP 4 formatted validation documentation
• Protocols submitted in advance of the equipment
Integrated Controls and Human Machine Interface (HMI)
• User friendly large color touch screen
Single-skid Design
• Fast installation saves time and money
• Smooth start-up
• Small footprint
Hot Water Sanitizable (optional on APEX™ system)
• Automated for reliable sanitization without chemicals
Proven Technologies
• RO and CDI-LX™ Systems for reliable, efficient and continuous operation
• Flexible configurations to meet your production needs
197
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SYSTEM, PreVUE® AND APEX™ VALIDATED SKIDDED
PreVUE® SystemsModular USP Purified Water Generation
PERFORMANCE SPECIFICATIONSModel 20 40 60 80 130 180 250
Maximum Product, gpm (m3/hr) 2.3 (.5) 4.4 (1) 6.6 (1.5) 8.8 (2) 15.3 (3.5) 19.8 (4.5) 28.8 (6.5)Nominal Product, gpm (m3/hr) 2.0 (.45) 4.0 (.9) 6.0 (1.4) 8.0 (1.8) 13.0 (2.9) 18.0 (4.1) 25.0 (5.7)Minimum Product, gpm (m3/hr) 1.5 (.3) 1.7 (.4) 3.4 (.8) 5.4 (1.2) 7.7 (1.7) 12.6 (2.9) 17.1 (3.9)Maximum Feed, gpm (m3/hr) 3.3 (.7) 6.5 (1.5) 9.7 (2.2) 13.1 (3) 22.7 (5.1) 29.3 (6.6) 42.7 (9.7)Maximum Drain, gpm (m3/hr) 10 (2.3) 12 (2.7) 15 (3.4) 20 (4.5) 30 (6.8) 40 (9.1) 60 (13.6)Nominal Recovery, % 64 68 68 68 68 68 68Inlet Pressure 60 to 95 psig regulated +/- 5 psigInlet Temperature 45 to 85°F (7.2 to 35°C)Note: Flow rates and recoveries are contingent upon feedwater quality. Pressure and temperature regulation required by customer. Contact your local Siemens WaterTechnologies sales representative for details.
PHYSICAL SPECIFICATIONSModel 20 40 60 80 130 180 250
Height 78” (198 cm) 78” (198 cm)Width 120” (305 cm) 120” (305 cm)Depth 60” (152 cm) 66” (168 cm)Shipping Weight, lbs (kgs) 3,300 (1497) 3,800 (1724) 4,400 (1996) 4,600 (2087) 6,300 (2858) 7,500 (3042) 8,600 (3901)Operating Weight, lbs (kgs) 4,200 (1905) 4,600 (2082) 5,500 (2495) 6,000 (2722) 8,400 (3810) 9,700 (4400) 11,900 (5398)Feed Water Inlet, Flanged 3/4” 1” 1” 1-1/2” 1-1/2” 2” 2”Product Outlet, Tri Clamp 1/2” 3/4” 3/4” 3/4” 1” 1” 1-1/2 ”Skid Drain, Flanged 2” 3”Break Tank Capacity 37 gallons (140 liters) 90 gallons (341 liters)
ELECTRICAL SPECIFICATIONSRequirements 480V, 3Ph
60 Hz
EQUIPMENT SPECIFICATIONSSofteners Fiberglass reinforced composite vessels with brass multiport valves (not hot water sanitizable)Activated Carbon Filter Stainless steel vessel, 100 psig ASME code with removable insulation jacketPretreatment Filter Stainless steel housing with 5.0 micron cartridge filterPretreatment UV Stainless steel chamber with 254 nm lampBreak Tank 316L stainless steel with bolted lidRO Pump Stainless steel vertical multi-stage centrifugal with VFDRO Vessels Fiberglass reinforced composite vessels, ASME codeRO Membranes Full fit thin film composite polyamide, hot water sanitizableCEDI Modules CDI-LX,™ hot water sanitizableFrame 304 Stainless steelControls PLC in NEMA 4X stainless steel enclosureHMI 10” color touch screen
OPTIONAL COMPONENTSSodium Bisulfite Injection Metering pump and solution tank with manual rate control, chlorine analyzer for alarmHardness Monitor Hardness analyzer integrated into control systempH Adjust Metering pump, solution tank and pH monitor with automatic rate control by control systemFinal UV Sanitary stainless steel chamber with 254 nm lampFinal Filter Sanitary stainless steel housing with 0.1 micron cartridge filter
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
198
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SYSTEM, PreVUE® AND APEX™ VALIDATED SKIDDED
APEX™ SystemsModular USP Purified Water Generation
PERFORMANCE SPECIFICATIONSModel 20 40 60 80 130 180 250
Maximum Product, gpm (m3/hr) 2.3 (.5) 4.4 (1) 6.6 (1.5) 8.8 (2) 15.3 (3.5) 19.8 (4.5) 28.8 (6.5)Nominal Product, gpm (m3/hr) 2.0 (.45) 4.0 (.9) 6.0 (1.4) 8.0 (1.8) 13.0 (2.9) 18.0 (4.1) 25.0 (5.7)Minimum Product, gpm (m3/hr) 1.5 (.3) 1.7 (.4) 3.4 (.8) 5.4 (1.2) 7.7 (1.7) 12.6 (2.9) 17.1 (3.9)Maximum Feed, gpm (m3/hr) 3.3 (.7) 6.5 (1.5) 9.7 (2.2) 13.1 (3) 22.7 (5.1) 29.3 (6.6) 42.7 (9.7)Maximum Drain, gpm (m3/hr) 10 (2.3) 12 (2.7) 15 (3.4) 20 (4.5) 30 (6.8) 40 (9.1) 60 (13.6)Nominal Recovery, % 64 68 68 68 68 68 68Inlet Pressure 60 to 95 psig regulated +/- 5 psigInlet Temperature 45 to 85°F (7.2 to 35°C)Note: Flow rates and recoveries are contingent upon feedwater quality. Pressure and temperature regulation required by customer. Contact your local Siemens WaterTechnologies sales representative for details.
PHYSICAL SPECIFICATIONSModel 20 40 60 80 130 180 250
Height 78” (198 cm) 78” (198 cm)Width 120” (305 cm) 120” (305 cm)Depth 60” (152 cm) 66” (168 cm)Shipping Weight, lbs (kgs) 3,300 (1497) 3,800 (1724) 4,400 (1996) 4,600 (2087) 6,300 (2858) 7,500 (3042) 8,600 (3901)Operating Weight, lbs (kgs) 4,200 (1905) 4,600 (2082) 5,500 (2495) 6,000 (2722) 8,400 (3810) 9,700 (4400) 11,900 (5398)Feed Water Inlet, Flanged 3/4” 1” 1” 1-1/2” 1-1/2” 2” 2”Product Outlet, Tri Clamp 1/2” 3/4” 3/4” 3/4” 1” 1” 1-1/2 ”Skid Drain, Flanged 2” 3”Break Tank Capacity 37 gallons (140 liters) 90 gallons (341 liters)
ELECTRICAL SPECIFICATIONSRequirements 480V, 3Ph 60 Hz
EQUIPMENT SPECIFICATIONSSofteners Fiberglass reinforced composite vessels with brass multiport valves (not hot water sanitizable)Activated Carbon Filter Stainless steel vessel, 100 psig ASME code with removable insulation jacketPretreatment Filter Stainless steel housing with 5.0 micron cartridge filterPretreatment UV Stainless steel chamber with 254 nm lampBreak Tank FRP dished bottomRO Pump Stainless steel vertical multi-stage centrifugal with VFDRO Vessels Fiberglass reinforced composite vessels, ASME codeRO Membranes Full fit thin film composite polyamide, hot water sanitizable (optional)CEDI Modules CDI-LX,™ hot water sanitizableFrame Polyurethane painted carbon steelControls PLC in NEMA 4 carbon steel enclosureHMI 10” color touch screen
OPTIONAL CONFIGURATIONSSulfite Dechlorination Metering pump and solution tank with manual rate control, chlorine analyzer for alarmHot Water Sanitization (APEX only) HWS option includes break tank heater, heater panel, and HWS membranesPermeate Piping (APEX only) Stainless steel piping (from RO/CEDI permeate)
OPTIONAL COMPONENTSSodium Bisulfite Injection Metering pump and solution tank with manual rate control, chlorine analyzer for alarmHardness Monitor Hardness analyzer integrated into control systempH Adjust Metering pump, solution tank and pH monitor with automatic rate control by control systemFinal UV Sanitary stainless steel chamber with 254 nm lampFinal Filter Sanitary stainless steel housing with 0.1 micron cartridge filter
In accordance with Siemens policy for continual product development and improvements, we reserve the right to change the product information within this literature at any time, without notice.
199
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
TEMPORARY MOBILE WATER TREATMENT
Mobile DemineralizationFlow Rates from 50 to 600 gpm
High capacity, multiplecombinations for
versatility of applications
For over 30 years, Siemens has met the short-term and emergency treated water needs of our customers using our mobile demineralizer (DI) trailers. These trailers are thetreatment of choice for zero-discharge applications and seasonal treated water needs. Areliable and extensive service network, an ever-expanding trailer fleet and strategicallylocated regeneration facilities allow Siemens Water Technologies to effectively serve ourlarge North American customer base.
Using mobile DI services, customers meet their treated water needs without on-site wastegeneration, hazardous chemical handling and capital investments. The following types oftrailers allow Siemens to match our customers’ exact capacity and flow needs with thecorrect trailer:• MT 3000 is our three-vessel trailer with up to 3 million grain capacity and flows to 200 gpm.• MT 4500 is our four-tank trailer that includes a weak-base anion vessel. With flows of
200 gpm and capacities up to 4 million grains on certain feedwaters, this trailer isideally suited for feedwaters with high free mineral acidity.
• MT 5000 is our largest mobile DI trailer with a nominal 5 million grain capacity. This isa two-train trailer with a flow of 300 gpm per train (600 gpm total).
• MT 5500 is a our six-vessel trailer with a nominal 5 million grain capacity. Thistrailer may be loaded in a variety of configurations to meet specific treatmentneeds at flow rates to 600 gpm.
Generally used for short-term or emergency needs, mobile demineralizer trailers havethe maximum versatility you need. These trailers are specially designed using cost-effective configurations allowing specific match to your site and feedwater conditions.They provide a convenient source of water for pilot facilities, system scale-ups andcommercialization product testing. They are ideal for use during start-ups, preventativemaintenance and breakdowns of existing equipment. They provide large quantities ofhigh-purity water rapidly with no on-site waste.
Very effective for lowercapacity, lower flow rate andlow TDS water applications
(especially for power industry)
Very effective for lowalkalinity / high FMA(free mineral acidity)
applications
Highest flow rate pertrailer in the industry,completely automatic
two-train system
SPECIFICATIONSSeries MT 3000 MT 4500 MT 5000 MT 5500
Nominal Exchange Capacity (kgr)* . . . . . . . . . . . . . . 3,000 4,500 5,000 5,000
Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Tanks/Trailer 4 Tanks/Trailer 6 Tanks/Trailer 6 Tanks/Trailer
Vessel Composition. . . . . . . . . . . . . . . . . . . . . . . . . . Carbon Steel Carbon Steel Carbon Steel Carbon Steel
Vessel Lining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vulcanized Rubber Vulcanized Rubber Vulcanized Rubber Vulcanized Rubber
ASME Code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Yes Yes Yes
Flow Rate (gpm) Min. / Max.. . . . . . . . . . . . . . . . . . . 50/200 50/200 50/600 50/400
Inlet Pressure (psig) Min. / Max. . . . . . . . . . . . . . . . . 45/100 50/100 40/100 40/100
Inlet / Outlet Hose Connections . . . . . . . . . . . . . . . . 2-1/2" Minimum 2-1/2" Minimum 2-1/2" Minimum 2-1/2"– 4" Minimum
Weight (lbs.) Shipping / Operating . . . . . . . . . . . . . . 35,000/42,000 47,000/62,000 60,000/84,500 58,000/84,500
Dimensions – Width x Length x Height . . . . . . . . . . . 8’ x 32’ x 13.5’ 8’ x 32’ x 13.5’ 8’ x 48’ x 13.5’ 8.5’ x 48’ x 13.5’
Trailer Electrical Requirements . . . . . . . . . . . . . . . . . . . 115V, Single Phase, 60 Hz, 10 Amps
Heater Electrical Requirements . . . . . . . . . . . . . . . . . . . (2) 115V, Single Phase, 60 Hz, 30 Amps
Instrumentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Indicator and Totalizer on Main Header
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pressure Gauges and Sample Ports
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conductivity Meters on Primary and Polish Outlet Ports
Feedwater Requirements . . . . . . . . . . . . . . . . . . . . . . . . Turbidity <3 NTU
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Free Chlorine <0.25 ppm
Typical Water Service Quality . . . . . . . . . . . . . . . . . . . . Conductivity: 0.1 - 1.0 µS/cm and Silica Leakage: <20 ppb
* Based on a 1µS/cm end point.
200
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
TEMPORARY MOBILE WATER TREATMENT
Mobile Clarification1.5 MGD Maximum
SPECIFICATIONS
Design Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 MGD, design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 MGD, maxOperating Weight – Dimensions (LxWxH) 48' x 8'6" x 13' 6" . 95,000 lbs.
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 feetWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 feet, 6 inchesHeight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 feet, 6 inches
Coagulation Tank HRT @ design . . . . . . . . . . . . . . . . . . . . . . 1.7 minutesInjection Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7 minutesMaturation Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 minutesSettling Tank Load Rate @ design . . . . . . . . . . . . . . . . . . . . . 30 gpm/ft2
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480V, 3ph, 100 ampsMechanical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8” flange inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10” flange outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4” flange drainInstrument–Influent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Raw water turbidity meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Raw water pH meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Raw water flow meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Coagulated water pH meterInstrument–Effluent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clarified water turbidity meterControl Panel–PLC-based . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA 12 UL® label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operator interface display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Signal isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O terminal strips
The mobile clarifier unit from Siemens Water Technologies is a self-contained trailer-
mounted system capable of treating highly turbid water (>1000 NTU). The system is
capable of producing extraordinarily clear effluent (0.5-1.0 NTU) with remarkable stability
under varying raw water conditions.
The Actiflo® clarification process from Kruger Inc. uses microsand as a seed to enhance
floc formation and increase settling rate. The microsand promotes production of higher
quality effluent than other types of clarification systems and is ideally suited for
treatment of raw water that is traditionally difficult to treat, such as: high or low
turbidity, high color/TOC, cold water, high algae, colloidal silica. Its stability, ease of
operation and small footprint make the clarifier trailer ideal for clarifying 750 gpm of
rapidly fluctuating raw water sources, in limited space and in frequent start-up/shut-
down applications. The system provides clear effluent water in even the most
demanding raw water conditions.
Mobile systems contain instrumentation and equipment for a fully automatic and
monitored operation. Chemical feed skids and fail safe shut-down controls are also
included to ensure efficient and reliable operation.
When using Siemens mobile systems, we guarantee quality, quantity and cost of
produced water. All mobile equipment is backed with an inventory of standard critical
components. Our skilled service team is on-call 24 hours per day to meet your needs. We
have over 80 local service facilities across the United States to service your needs.
201
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
TEMPORARY MOBILE WATER TREATMENT
Mobile Reverse Osmosis (RO)
The Mobile RO unit from Siemens Water Technologies is a self-contained system that
employs pretreatment and reverse osmosis (RO) capability in a single trailer. The system
is capable of producing 200 gpm of low conductivity product water under a variety of
raw water conditions.
The versatile 200 gpm Mobile RO trailer can provide multi-media, carbon, or softening
pretreatment consistent with the raw water’s impurities. The trailer can be configured
as a 90 gpm double-pass unit for applications requiring extensive DI polishing. This
approach can reduce DI polishing costs by as much as 80-90%.
Because the RO unit combines pretreatment and RO in a single trailer, installation costs
and response times are reduced significantly. This means lower produced water costs
and minimum downtime for Siemens Water Technologies customers. Mobile systems
contain instrumentation and equipment for fully automatic and monitored operation.
Chemical feed skids and fail-safe shut-down controls are also included to ensure
efficient and reliable operation.
Siemens backs its mobile systems with a guarantee of quality, quantity and cost of
produced water. All mobile equipment is supported by an inventory of standard critical
components. A skilled service team is on-call 24 hours per day to respond to your needs.
SPECIFICATIONS
Dimensions (LxWxH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48’ x 8.5’ x 13.5’Weight (Shipping/Operating) . . . . . . . . . . . . . . . . . . . . . . . . . . . 55,000 lbs. Max./70,000 lbs.Feed Water (gpm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133-506Product Water (gpm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90-200Drain (gpm)
Concentrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-66Backwash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80-240
Pressure (psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50-90Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480 VAC/3 ph/200 AmpAir Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 SCFM @ 80 psigService Connections (150# PVC Flange)
Inlet/Outlet/Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4”/4”/4”Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA 4X w/Allen-Bradley® SLC-5/03
PLC Remote I/O – PLC InterfacePretreatment Vessels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 x 54" dia. (45-60 ft3) each
Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Carbon, filter media (various), resinFlexRO®-100 Units
Membranes (3:2:1 Array) . . . . . . . . . . . . . . . . . . . . . . . . . 24 ea (TFC or CA)Prefilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 SS, 12 round x 3 highPump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 HP Multi-stage
InstrumentationFlow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product/ConcentrateSpecific Conductance . . . . . . . . . . . . . . . . . . . . . . . . . . . Feed/ProductpH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FeedORP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FeedPressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Various
202
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
TEMPORARY MOBILE WATER TREATMENT
PreFlex® Pretreatment Units
PreFlex® pretreatment units from Siemens Water Technologies are modular in design,pre-plumbed, self-contained, skid-mounted units used in our mobile business. PreFlex®units are designed to the highest engineering standards with ASME code tanks, NEMA4X panels and pneumatically actuated solenoid valves enabling them to be used in awide variety of applications and environments including heavy industry.
Configured in parallel or series, these units can be combined with other Siemens mobileproducts for a fully integrated water treatment system meeting your plant’s flow andquality requirements. Units may be site or trailer installed with up to six PreFlex® 54units per trailer.
Siemens Water Technologies maintains a large inventory of PreFlex® units and othermobile assets as we continue to serve a large number of companies who depend uponSiemens’ mobile capabilities and extensive service network for their short-term,emergency, seasonal, pilot and temporary water treatment needs.
PreFlex® units are also used for various stand-alone pretreatment applicationsincluding:
• Media filtration • Activated carbon filtration
• Softening • Dealkalization
• Iron and manganese removal • TOC reduction
PreFlex® units are generally used for temporary needs including:
• Capacity expansions • Pilot plant water
• Interim usage until a permanent system is installed • Process water quality changes
• Scheduled shutdowns • Seasonal water needs
• Emergency water usages • Feedwater quality changes
• Existing demineralization system environmental salt discharge problems
PreFlex 54 PreFlex 84
ACF MMF SOFT ACF MMF SOFT
Service Flow Rate (gpm) - Min./Max. 40/160 40/120 40/240 80/380 80/300 80/500Backwash Flow (gpm). . . . . . . . . 160 240 80 380 540 200Media Volume (Ft3) . . . . . . . . . . . 45 45 60 120 120 150Exchange Capacity @ 10#/ft3
Salt Dosage (kgr) . . . . . . . . . N/A N/A 1,500 N/A N/A 3,750Operating Pressure (psi) - Min./Max. 20 / 100 20 / 100Pressure Drop (psig) . . . . . . . . . . 5 - 15 5 - 15Operating Temp. (°F), Max. . . . . 105 105Service Connections - Sch. 80 PVCInlet / Outlet / Waste (inches). . . 4/4/4 6/6/4 or 6/6/6Weight (lbs.) - Shipping . . . . . . . . 2,700 2,700 2,700 7,700 7,700 7,700
- Operating . . . . . . . . . . . . 9,100 12,500 10,200 24,600 32,200 27,500Dimensions. . . . . . . . . . . . . . . . . . 54" W x 73" D x 97" H 92" W x 108" D x 128" HElectric Requirements . . . . . . . . . 120 V / 1 ph / 60 Hz - 10 AmpsType. . . . . . . . . . . . . . . . . . . . . . . Carbon Steel, ASME Code, 100 psiInternal Lining . . . . . . . . . . . . . . . Epoxy/PolyurethaneValves / Piping / Internals. . . . . . Butterfly Isolation & Solenoid Valves / Sch. 80 PVC / SS 316 Bottom. . . . . . . . . . . . . . . . . . . . . . . . . . . & PVC Top Distribution
Air Requirements . . . . . . . . . . . . . 10 SCFM (Instantaneous) @ 80 psigControl Panel . . . . . . . . . . . . . . . . NEMA 4X, Remote I/O Solenoid PanelGauges. . . . . . . . . . . . . . . . . . . . . In / Out PressureApplications . . . . . . . . . . . . . . . . . Activated Carbon (ACF) Fe and Mn Removal Softening
Multimedia (MMF) TOC Removal Dealkalization
203
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SPECIFICATIONSFlexTrex® 36 FlexTrex® 42 FlexTrex® 48 Super 30
Vessel Size . . . . . . . . . . . . . . . . . . . . . . . 36" x 48" Side Sheet 42" x 48" Side Sheet 48" x 60" Side Sheet 36" dia. X 54" Side SheetMedia Volume (ft3) . . . . . . . . . . . . . . . . . 30 42 60 30Service Flow Rate (gpm) Min/Max. . . . . 20 / 100 35 / 150 35 / 250 20 / 100Pressure Drop (psig) at 77°F . . . . . . . . . Approx. 15 at 100 gpm Approx. 15 at 150 gpm Approx. 10 at 250 gpm Approx. 25 at 100 gpmResin . . . . . . . . . . . . . . . . . . . . . . . . . . . SAC/SBA/MB SAC/SBA/MB SAC/SBA/MB SAC/SBA/MBExchange Cap. (kgr) . . . . . . . . . . . . . . . 750/420/240 1050/588/336 1500/840/480 750/420/240Operating Pressure (psi) Min/Max. . . . . 20/100 20/100 20/100 20/100Operating Temperature (˚F) Max. . . . . . 100 140 (SS only) 100 100Service Connections . . . . . . . . . . . . . . . 2" or 3" 3" 4" 2"Vessel Specifications . . . . . . . . . . . . . . .
Type . . . . . . . . . . . . . . . . . . . . . . . . . Carbon Steel 316L SS Carbon Steel Carbon SteelInternal Lining . . . . . . . . . . . . . . . . . . Vulcanized Rubber Lined None Vulcanized Rubber Lined Sprayed & Baked PVC
Piping/Internals . . . . . . . . . . . . . . . . . . . . Sch. 80 PVC Sch. 80 PVC / 316 SS Sch. 80 PVC Sch. 80 PVCWeight (lbs.) Shipping/Operating . . . . . . 2,000 / 3,400 3,500 / 4,200 5,000 / 8,000 2,000 / 3,400Dimensions (WxDxH) . . . . . . . . . . . . . . . 40"x42"x78" 42"x49"x90" 50"x61"x92" 36"x36"x76" Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lifting Lugs & Fork Lift Ports Provided -- Units Movable By Pallet Jack
Media Options: . . . . . . . . . . . . . . . . . . . . . . .
Strong Acid Cation Resin (SAC) Weak Base Anion Resin (WBA) Organic Scavenging MediaStrong Base Anion Resin (SBA) Mixed Bed Resin (MB) Colloidal Removal MediaWeak Acid Cation Resin (WAC) Activated Carbon
TEMPORARY MOBILE WATER TREATMENT
FlexTrex® Deionization UnitsFlow Rates to 250 gpm
FlexTrex® deionization units from Siemens Water Technologies are skid-mounted ionexchange units designed to treat flows ranging from 20 to 250 gpm per unit. FlexTrex®units have quick disconnects and can be installed and brought on-line in a very shortperiod of time using flexible hoses.
Regenerated off-site, these portable units do not use hazardous chemicals, do notgenerate any wastewater and are ideal for polishing raw or RO permeate water. Incertain instances, FlexTrex® units are an economical alternative to service deionizationbottles. These ASME tanks, with their rugged design, small footprint and ability to treathigh flow rates, are of tremendous advantage in many instances. With their 316 SSconstruction, FlexTrex® 42 units treat water up to 140°F and are ideal for short or long-term condensate polishing applications.
FlexTrex® units can be configured in parallel or series and combined with other Siemensproducts for a fully integrated water treatment system to meet your plant’s specific flowand quality requirements. They are serviced and exchanged by Siemens’ extensive andreliable service network, which is available 24 hours a day. Our regeneration facilitiesand experienced service personnel ensure you receive an uninterrupted, consistentsupply of treated water of the quality and quantity you require.
Siemens can add controls and instrumentation to these units on an as-needed basis tomeet your application needs.
FlexTrex® modules are generally used for:
• Polishing • Pilot plant water needs
• Process water quality changes • Chlorine or chloramine removal
• Scheduled shutdowns • Seasonal water needs
• Emergency water usages • Feedwater quality changes
• Condensate polishing • Softening
• Interim usage until a permanent system is installed
204
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
TEMPORARY MOBILE WATER TREATMENT
FlexRO® Reverse Osmosis Units
FlexRO® reverse osmosis units from Siemens Water Technologies are skid-mounted,self-contained, 100 and 125 gpm reverse osmosis units. These units feature arrayskids with:
• SS cartridge filter housing
• TEFC high efficiency motor
• Multistage high pressure pump
• State-of-the-art instrumentation
• NEMA 4X 480 VAC motor, starter panel with a 120 VAC step-down transformer
• Separate NEMA 4X control panel with PLC
With their rugged, modular design, FlexRO® units are convenient to install, connect,startup and service. These units may be site installed and operated as stand-aloneunits or installed inside a trailer (4 FlexRO® 100 units per trailer) and controlled bythe system panel. Combined with other Siemens Water Technologies mobile assets,FlexRO® units are used to assemble fully integrated water treatment systemsdesigned to customers’ specific treated water quality and flow needs. These unitsare economical even on low TDS feedwater. Operating as a pretreatment todeionizers (DI), these units significantly reduce consumption of hazardouschemicals, labor and waste; extend DI service cycles; and improve treated waterquality. Units may be installed in parallel for single pass or in series for double passapplications. Both thin film composite (TFC) and cellulose acetate (CA) membranesmay be used in these units. Large inventories of mobile units, coupled with anextensive service network enable us to respond quickly to our customers’ seasonal,emergency, pilot or other short-term water treatment needs.
SPECIFICATIONSFlexRO 100 Units: FlexRO 100 FlexRO 125
Flow Rate @ 59°F gpmPermeate / Concentrate / Feed . . . . . . . . . . . . . 100/33/133 125/42/167
Membranes (TFC or CA*)Array / Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . 3:2:1 (4M) / 24 4:2:1 (4M) / 28
Starter Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA 4X -- Includes 120 VAC step-down transformerMotor Size, HP / Amps . . . . . . . . . . . . . . . . . . . . 50/65Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460 VAC / 3 ph / 60 Hz
Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA 4X with PLCOption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote I/O Panel / PLC Interface
Connections (Schedule 80 PVC)Feed / Permeate / Concentrate . . . . . . . . . . . . . 3" / 3" / 1.5" Flanged 4" / 3" / 1.5" Flanged
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16' L X 3' D X 6'10" H 17" L x 3'4" D x 8'1" HWeight (lbs.) Shipping / Operating. . . . . . . . . . . . . 5,200 / 6,500 5,300 / 6,800Pressure Gauge. . . . . . . . . . . . . . . . . . . . . . . . . . . Cartridge Filter In/Out; Pump Discharge (Feed to Membrane); Interstage; Concentrate; PermeateTemperature Gauge . . . . . . . . . . . . . . . . . . . . . . . . FeedFlow Indicator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Permeate and ConcentrateConductivity Analyzer. . . . . . . . . . . . . . . . . . . . . . . Feed and PermeateCartridge Filter Housing . . . . . . . . . . . . . . . . . . . . . SS, 12 Round x 3 High*Flows and recovery rates will be different with cellulose acetate membranes.
205
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ULTRAVIOLET STERILIZERS
ZCS Series
CSL-Series Ultraviolet Lights
SP, SL and MP-2 Series Ultraviolet Lights
Ultraviolet Light Sterilizers
UV radiation can be used as a pretreatment or polishing step to destroy bacteria and to
reduce total organics. Low pressure mercury discharge lamps are used to generate the
UV energy, emitted at either 254 or 185 nm. The UV energy emitted at 254 nm is used
as a non-chemical method for destroying microorganisms by altering the genetic
material, and rendering them unable to reproduce. The shorter, and therefore more
powerful 185 nm energy is used for the effective reduction of organics, commonly
referred to as TOC (total oxidizable carbon).
The UV units are manufactured from 304 stainless steel. The UV light rays produced by
each lamp efficiently pass through the quartz sleeves and into the surrounding liquid
flowing through the UV treatment chamber. Stainless baffles are included in the
treatment chamber to induce turbulence and prevent channeling, maximizing the
exposure to ultraviolet radiation.
SPECIFICATIONS FOR ZCS SERIES 254nm ULTRAVIOLET STERILIZERSModel Number SP-1 SP-2 SL-10A SL-1 MP-2-SL
Catalog Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSL00110 ZCSL00210 ZCSL00410 ZCSL01210 ZCSL02410No of UV lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 2Max Design Flow (gpm)
Clear water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 3 10 20RO/DI water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 4 12 24
Standard Operating Press (psig)(8.3 bar) . . . . . . . . . . . 120 120 120 120 120Inlet/Outlet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . 3/8" NPTF 3/8" NPTF 1/2"150# flange 1" 150# flange 1.5" 150# flangeDimensions (LxWxH) inch . . . . . . . . . . . . . . . . . . 14x4x5 14x4x5 10x6x19 14x7x38 38x7x21
cm . . . . . . . . . . . . . . . . . . . 36x9x13 36x9x13 26x16x48 36x17x97 97x18x53
Model Number CSL-4R CSL-6R CSL-8R CSL-12R
Catalog Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSL05010 ZCSL07810 ZCSL10010 ZCSL15610No of UV lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 6 8 12Max Design Flow (gpm)
Clear water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 60 80 130RO/DI water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 78 100 156
Standard Operating Press (psig)(8.3 bar) . . . . . . . . . . . 120 120 120 120Inlet/Outlet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . 2" 150# flange 2" 150# flange 3" 150# flange 3" 150# flangeDimensions (LxWxH) inch . . . . . . . . . . . . . . . . . . 41x11x21 41x11x21 45x12x28 45x12x28
cm . . . . . . . . . . . . . . . . . . . 104x28x53 104x28x53 104x28x53 114x33x67
UV STERILIZERS SPARE PARTSModel Number SP-1 SP-2 SL-10A SL-1 MP-2-SL
Replacement Lamp 254nm (dual ended) . . . . . . . . . . . ZCSPL3010 ZCSPL3011 ZCSPL3050 ZCSPL3084 ZCSPL3084 Validated Lamp 254nm (dual ended) . . . . . . . . . . . . . . . — — ZCSPL16714 ZCSPL16676 ZCSPL16676Replacement Magnetic Ballast. . . . . . . . . . . . . . . . . . . . ZCSPB3318 ZCSPB3910 ZCSPB4035 ZCSPB4035 ZCSPB3354Replacement Quartz Sleeve (dual ended). . . . . . . . . . . ZCSPQ3110 ZCSPQ3110 ZCSPQ3150 ZCSPQ3184 ZCSPQ3184
Model Number CSL-4R CSL-6R CSL-8R CSL-12R
Replacement Lamp 254nm (dual ended) . . . . . . . . . . . ZCSPL3084 ZCSPL3084 ZCSPL3084 ZCSPL3084Replacement Lamp 254 (single ended) . . . . . . . . . . . . . ZCSPL17491 ZCSPL17491 ZCSPL17491 ZCSPL17491Validated Lamp 254nm (dual ended) . . . . . . . . . . . . . . . ZCSPL16676 ZCSPL16676 ZCSPL16676 ZCSPL16676Validated Lamp 254nm (single ended). . . . . . . . . . . . . . ZCSPL18059 ZCSPL18059 ZCSPL18059 ZCSPL18059Replacement Magnetic Ballast. . . . . . . . . . . . . . . . . . . . ZCSPB3354 ZCSPB3354 ZCSPB3354 ZCSPB3354Replacement Electronic Ballast . . . . . . . . . . . . . . . . . . . ZCSPB16518 ZCSPB16518 ZCSPB16518 ZCSPB16518Replacement Quartz Sleeve (dual ended) . . . . . . . . . . . ZCSPQ3184 ZCSPQ3184 ZCSPQ3184 ZCSPQ3184Replacement Quartz Sleeve (single ended) . . . . . . . . . ZCSPQ18347 ZCSPQ18347 ZCSPQ18347 ZCSPQ18347
NOTE: Thermistors, optical sensors, sanitary connections, ozone destruction, hot temperature units, light traps, and remote electrical controls are available. Please contact Technical Support for detailed information. Mating flanges are not supplied with units.
206
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
ULTRAVIOLET STERILIZERS
ZHX Series
SPECIFICATIONS
Model Number . . . . . . . . . . . . . . . . . . . . . . . . HX02BDS HX02BDL HX02DDS HX02CDLCatalog Number . . . . . . . . . . . . . . . . . . . . . . . ZHXN04520 ZHXN09020 ZHXN11520 ZHXN15020No of UV Lamps . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 2Max Flow (gpm) RO/DI . . . . . . . . . . . . . . . . . . 45 90 115 150Std. Oper Press (psig) . . . . . . . . . . . . . . . . . . . 150 150 150 120Inlet/Outlet Connection . . . . . . . . . . . . . . . . . . . 2” RF Flange 2” RF Flange 3” RF Flange 3” RF FlangeDimensions (inches) . . . . . . . . . . . . . . . . . . . . . 38x12x15 68x12x15 40x16x22 68x10x22
Model Number . . . . . . . . . . . . . . . . . . . . . . . . HX02DDL HX04CDL HX06CDLCatalog Number . . . . . . . . . . . . . . . . . . . . . . . ZHXN22020 ZHXN30020 ZHXN40520No of UV Lamps . . . . . . . . . . . . . . . . . . . . . . . . 2 4 6Max Flow (gpm) RO/DI . . . . . . . . . . . . . . . . . . 220 300 405Std. Oper Press (psig) . . . . . . . . . . . . . . . . . . . 150 120 120Inlet/Outlet Connection . . . . . . . . . . . . . . . . . . . 3” RF Flange 4” RF Flange 4” RF FlangeDimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 68x12x24 68x10x22 68x10x22
The next generation of UV systems utilize a new low pressure high intensitylong-life bulb that greatly increases the capacity per unit. This technologyrequires up to 4 times less bulbs to accommodate the same flow as original lampdesigned systems.• Hot water sanitizable with UV detector to 121˚C in place• Disinfection 30,000 uW-s/cm2
• 240V/50Hz or 60Hz• 9,000 hour life at 80% intensity end of life• Temperature and UV combined in one detector package (option)• Option for NIST traceable optical detector• Option for UL Listed
SPARE PARTS
HX - UV Sterilizer Spare Parts (30" for 45 and 115 gpm models,60" for all others)
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number254nm Lamp 30" . . . . . . . . . . . . . . . . . . . . . . . ZCSPLGOLD-S254nm Lamp 60" . . . . . . . . . . . . . . . . . . . . . . . ZCSPLGOLD-L254nm Validated Lamp 30" . . . . . . . . . . . . . . . ZCSPLCREAM-S254nm Validated Lamp 60" . . . . . . . . . . . . . . . ZCSPLCREAM-L185nm Lamp 30" . . . . . . . . . . . . . . . . . . . . . . . ZCSPLSILVER-S185nm Lamp 60" . . . . . . . . . . . . . . . . . . . . . . . ZCSPLSILVER-L185nm Validated Lamp 30" . . . . . . . . . . . . . . . ZCSPLTAN-S185nm Validated Lamp 60" . . . . . . . . . . . . . . . ZCSPLTAN-L30" Quartz Sleeve . . . . . . . . . . . . . . . . . . . . . . ZCSPQ318460" Quartz Sleeve . . . . . . . . . . . . . . . . . . . . . . ZCSPQ3198Ballasts Electronic . . . . . . . . . . . . . . . . . . . . . . ZCSPB416341Compression nuts . . . . . . . . . . . . . . . . . . . . . . ZCSPM19685O-Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM4253
Additional higher flow models are available. Contact Technical Support.
207
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ULTRAVIOLET STERILIZERS
ZCT Series
SPECIFICATIONS FOR ZCT SERIES 185nm ULTRAVIOLET LIGHTSModel Number SL-1 TOC MP-2-SL TOC CSL-4R TOC CSL-6R TOC CSL-8R TOC CSL-12R TOC
Catalog Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCTOOO310 ZCTOOO510 ZCTOO1110 ZCTOO1710 ZCTOO2210 ZCTOO3510No of UV lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 4 6 8 12Max Design Flow (gpm) RO/DI water . . . . . . . . . . . . . . 3 5 11 17 22 35Design Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 5 11 17 22 35Standard Operating Press (psig) . . . . . . . . . . . . . . . . . . 120 120 120 120 120 120Inlet/Outlet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . 1" 150# flange 1.5"150# flange 2" 150# flange 2" 150# flange 2” 150# flange 3” 150# flangeDimensions LxWxH inch . . . . . . . . . . . . . . . . . . . . . . . 14x7x38 38x7x21 41x11x21 41x11x21 41x11x21 45x13x27
cm . . . . . . . . . . . . . . . . . . . . . . . . 36x 18x97 97x18x53 104x28x53 104x28x53 104x28x53 114x33x69Model Number CSL-8R/60 TOC CSL-10R/60 TOC CSL-12R/60 TOC CSL-16R/60 TOC CSL-20R/60 TOC CSL-24R/60 TOC
Catalog Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCTOO4510 ZCTOO5810 ZCTOO7010 ZCTOO9010 ZCTO11510 ZCTO14010No of UV lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 10 12 16 20 24Max Design Flow (gpm) RO/DI water . . . . . . . . . . . . . . 45 58 70 90 115 140Design Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 58 70 90 115 140Standard Operating Press (psig) . . . . . . . . . . . . . . . . . . 120 120 120 120 120 120Inlet/Outlet Connection. . . . . . . . . . . . . . . . . . . . . . . . . . 4" 150# flange 4" 150# flange 4" 150# flange 4" 150# flange 4” 150# flange 4” 150# flangeDimensions LxWxH inch . . . . . . . . . . . . . . . . . . . . . . . 69x13x27 69x13x27 69x13x27 69x13x27 69x13x27 69x13x27
cm . . . . . . . . . . . . . . . . . . . . . . . . 175x33x69 175x33x69 175x33x69 175x61x66 175x61x66 175x61x66UV LIGHT SPARE PARTS
Model Number SL-1 TOC MP-2-SL TOC CSL-4R TOC CSL-6R TOC CSL-8R TOC CSL-12R TOC
Replacement Lamp 185nm (dual ended). . . . . . . . . . . . ZCSPL3087 ZCSPL3087 ZCSPL3087 ZCSPL3087 ZCSPL3087 ZCSPL3087Replacement Lamp 185nm (single ended) . . . . . . . . . . ZCSPL18063 ZCSPL18063 ZCSPL18063 ZCSPL18063ValidatedLamp 185nm (dual ended) . . . . . . . . . . . . . . . . . . . . . . . ZCSPL16678 ZCSPL16678 ZCSPL16678 ZCSPL16678 ZCSPL16678 ZCSPL16678ValidatedLamp 185nm (single ended) . . . . . . . . . . . . . . . . . . . . . ZCSPL18062 ZCSPL18062 ZCSPL18062 ZCSPL18062Replacement Magnetic Ballast. . . . . . . . . . . . . . . . . . . . ZCSPB4035 ZCSPB3101 ZCSPB3354 ZCSPB3354 ZCSPB3354 ZCSPB3354Replacement Electronic Ballast . . . . . . . . . . . . . . . . . . . ZCSPB16518 ZCSPB16518 ZCSPB16518 ZCSPB16518Replacement Quartz Sleeve (dual ended) . . . . . . . . . . . ZCSPQ3184 ZCSPQ3184 ZCSPQ3184 ZCSPQ3184 ZCSPQ3184 ZCSPQ3184Replacement Quartz Sleeve (single ended) . . . . . . . . . ZCSPQ18347 ZCSPQ18347 ZCSPQ18347 ZCSPQ18347
Model Number CSL-8R/60 TOC CSL-10R/60 TOC CSL-12R/60 TOC CSL-16R/60 TOC CSL-20R/60 TOC CSL-24R/60 TOC
Replacement Lamp 185nm (dual ended). . . . . . . . . . . . ZCSPL3095 ZCSPL3095 ZCSPL3095 ZCSPL3095 ZCSPL3095 ZCSPL3095Replacement Lamp 185nm (single ended) . . . . . . . . . . ZCSPL17498 ZCSPL17498 ZCSPL17498 ZCSPL17498 ZCSPL17498 ZCSPL17498ValidatedLamp 185nm (dual ended) . . . . . . . . . . . . . . . . . . . . . . . ZCSPL16679 ZCSPL16679 ZCSPL16679 ZCSPL16679 ZCSPL16679 ZCSPL16679ValidatedLamp 185nm (single ended) . . . . . . . . . . . . . . . . . . . . . ZCSPL18061 ZCSPL18061 ZCSPL18061 ZCSPL18061 ZCSPL18061 ZCSPL18061Replacement Magnetic Ballast. . . . . . . . . . . . . . . . . . . . ZCSPB3354 ZCSPB3354 ZCSPB3354 ZCSPB3354 ZCSPB3354 ZCSPB3354Replacement Quartz Sleeve (dual ended). . . . . . . . . . . ZCSPQ3198 ZCSPQ3198 ZCSPQ3198 ZCSPQ3198 ZCSPQ3198 ZCSPQ3198Replacement Quartz Sleeve (single ended) . . . . . . . . . ZCSPQ18348 ZCSPQ18348 ZCSPQ18348 ZCSPQ18348 ZCSPQ18348 ZCSPQ18348
NOTE: Thermistors, optical sensors, sanitary connections, ozone destruction, hot temperature units, light traps, and remote electrical controls are available. Please contact Technical Support for detailed information. Mating flanges are not supplied with units.
208
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
ULTRAVIOLET STERILIZERS
Replacement UV Monitoring SystemKits for Aquafine® Series UV Sterilizers
Upgrade existing UV sensors with new premium UV and temperature
monitoring technology.
An integrated NIST traceable (optional) UV and temperature monitoring system
will accurately monitor UV intensity and process water temperature of your
existing UV treatment equipment from Aquafine. The new design improves
reliability and performance accuracy in one state-of-the-art monitoring technology
system. Component cost savings and improved liability protection will be some of
the key benefits you will have with this state-of-the-art monitoring system. The
detector employs a Gallium Nitride (GaN) photodiode and a semiconductor
temperature sensor in a single package, along with its on-board electronics for
remote and local operation features:
• Detector: UV and temperature sensors in a single housing
• Optional NIST-traceable UV sensor calibration with certificate upon request
• No optical filters, no degradation
• Withstands non-operating temperatures of 250°F
• 121°C for steam sterilization at a maximum pressure of 250psi (17.2 bar)
• Complete on-board electronics for UV and temperature
• Absolute and percent UV readout options
• Detector Cable: Water-resistant axial connector and cabling
• No diffuser, therefore no UV solarization
• Temperature sensor and controller does not require calibration
• Detector can be used for UV Monitoring Station and Aqualogic 2000™ system.
209
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ULTRAVIOLET STERILIZERS
Replacement UV Monitoring SystemKits for Aquafine® Series UV Sterilizers
Ordering Information for Kits.
Remote UV Monitoring SystemThis kit is intended as a remote self-contained, wall or cabinet mounted,monitoring station and detector for use with any Aquafine units.
Standard Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM41628NIST Traceable Kit . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM416281
CSL Monitoring SystemThis kit is intended to upgrade existing CSL units with the new monitoring stationand detector.*
Standard Remote Integrated Kit . . . . . . . . . . . . . . ZCSPM41550NIST Traceable Remote Integrated Kit . . . . . . . . . ZCSPM415501*Note: Dual Chamber units require two kits
Spare PartsDetector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM41174NIST Traceable Detector . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM411741Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM41116CPVC Compression nut . . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM4252SS Compression Nut . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM40317O-Ring (Viton®) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZCSPM40432
210
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
ULTRAVIOLET STERILIZERS
Ultraviolet Light Traps
Non-metallic piping systems that employ ultraviolet (UV) sterilization are susceptible to
photochemical degradation. These piping systems must be protected from the effects of
ultraviolet light emitted by the UV unit through the use of “UV Light Traps.” This line of
light traps has been developed to provide that protection; traps should be installed at
the inlet and outlet of the UV sterilization unit prior to connecting the unit to any non-
metallic piping material. All traps in this product line are constructed of 316L stainless
steel, OD tube size, and are shipped complete with gasket (flange or sanitary) and
hardware (flange bolts and/or sanitary clamp) as applicable.
• Each trap is ordered separately permitting greater flexibility in selecting end
connection configurations
• Pre-fabricated traps ship complete with all gaskets and hardware appropriate for
the end connections selected
• Sizing flexibility ranges from 1/2" flange or ferrule through 4" flange or ferrule
SPECIFICATIONSSLT TTE 20 TC
“S” Shaped Traps . . . . . . . . . . . SLT FFM - Flange x Flange - Mill Finish 05 - 1/2" Flange / Ferrule FFE - Flange x Flange - Electropolished (flange ring not available)FTE - Flange x Sanitary - Electropolished 10 - 1" Flange Ring / Ferrule
End Connection. . . . . . . . . . . . . . . . . . . . . . TTE - Sanitary x Sanitary - Electropolished 15 - 1-1/2" Flange Ring / Ferrule20 - 2" Flange Ring / Ferrule XX - No port for resistivity element30 - 3" Flange Ring / Ferrule HC - 3/4" Half Coupling (threaded
Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 - 4" Flange Ring / Ferrule resistivity element (FF connections only)Re Port Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TC - 1-1/2" Ferrule (sanitary resistivity
element) used for 2" tubeTC - 2" Ferrule (sanitary resistivity element)
used for 3" and 4" tube
SPECIFICATIONSYLT 430 V
“Y” Shaped Traps . . . . . . . . . . . YLT 325 - 3" Flanged UV connections, 2.5" flanged common inlet / outlet 330 - 3" Flanged UV connections, 3" flanged common inlet / outlet 430 - 4" Flanged UV connections, 3" flanged common inlet / outlet
End Connection. . . . . . . . . . . . . . . . . . . . . . 440 - 4" Flanged UV connections, 4" flanged common inlet / outlet V - Vertical inlet / outletConnection Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H - Horizontal inlet / outlet
211
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
VALVES
Blend Valves
Water Temperature Blend Valves are designed to temper the inlet water to a waterpurification system, to optimize the water system’s performance. The valve is suppliedwith a temperature controller (blend valve), brass nipple and brass cross fittings, andinline dial thermometer.
• Controls temperatures from 20°C to 45°C, with an optimum temperature of 25°C.Temperature setting is field-adjusted upon installation.
• Thermostatic controller constructed of rough brass, chrome-plated, with an integralstop check strainer, and removable thermostatic cartridge for ease of maintenance.Control knob is constructed of stainless steel.
• Wall mounting bracket is optional
SYSTEM SPECIFICATIONS
Catalog Number . . . . . . . . . . VALRVT050VPV ZIVC00141 ZIVC00142 VALRVT125VPV ZIVC00143 VALRVT200VPV
Body Type . . . . . . . . . . . . . . . . . . PVC PVC PVC PVC PVC PVCO-ring . . . . . . . . . . . . . . . . . . . . . . Viton® Viton® Viton® Viton® Viton® Viton®
Capacity . . . . . . . . . . . . . . . . . . . . 4 gpm 8 gpm 15 gpm 25 gpm 50gpm 80gpmConnection . . . . . . . . . . . . . . . . . 1/2" 3/4" 1" 11⁄4" 11⁄2" 2"
Catalog Number . . . . . . . . . . VALRVT050VPP VALRVT075VPP VALRVT100VPP VALRVT150VPP VALRVT200VPP
Body Type . . . . . . . . . . . . . . . . . . Polypro Polypro Polypro Polypro PolyproO-ring . . . . . . . . . . . . . . . . . . . . . . Viton® Viton® Viton® Viton® Viton®Capacity . . . . . . . . . . . . . . . . . . . . 4 gpm 8 gpm 15 gpm 50 gpm 80gpmConnection . . . . . . . . . . . . . . . . . 1/2" 3/4" 1" 11⁄2" 2"
SYSTEM SPECIFICATIONS
Catalog Number ZR2523001 ZR2523002 ZR2523003 ZR2523004 ZR2523005 ZR2523006
Type . . . . . . . . . . . . . . . . . . . . . . 5-200-1 5-400-1 5-200 5-400 5-700 5-900Flow range . . . . . . . . . . . . . . . . . 4–5 6–10 10–18 19–30 31–45 45–60Pressure drop . . . . . . . . . . . . . . 5–10 6–10 7–18 5–13 5–10 5–12Inlet size. . . . . . . . . . . . . . . . . . . 3/4" 3/4" 3/4" 3/4" 11⁄4" 11⁄2"Outlet size . . . . . . . . . . . . . . . . . 3/4" 1" 3/4" 1" 11⁄2" 11⁄2"
System DimensionsL x W x D (inches) . . . . . . . . . . . 11x6x73⁄4 11x61⁄4x8 11x6x73⁄4 11x61⁄4x8 12x61⁄2x101⁄8 13x7x121⁄2
Shipping Weightlbs. . . . . . . . . . . . . . . . . . . . . . . . 10 14 10 14 18 27
Optional MountingBracket (Catalog Number) ZR2523008 ZR2523008 ZR2523008 ZR2523008 ZR2523008 ZR2523009
Pressure Relief ValvesSiemens pressure relief valves are designed to prevent over pressures, maintain back pressures or act as an automatic by-pass invessels and piping. The pressure relief valves can handle corrosive and ultra-pure liquids with inlet pressures up to 100 psi. Thepressure relief valves are designed to activate at the desired set point, and contain a Teflon shaft for non-sticking operation.
212
Siemens Water Technologies24-hr Customer Service: 800.466.7873
BACK Main Table of Contents
WASTEWATER
Wastewater Capabilities
Preliminary Treatment/Pre-treatmentIntake systems, screens and rakes
Grit removal
Pumps
Flow equalization
Aeration
Odor control
Media filtration
Clarification
pH adjustment
Oil/Water SeparationAPI separators
Plate separators
Hydrocyclone separators
DAF/DGD Separators
IAF/IGD Separators
Skimmers
Walnut shell filters
Chemical Precipitation/NeutralizationChemical feed systems
Bulk chemical handling
Lime slakers
Batch and continuous precipitation units
Membrane systems
ClarificationClarifiers
High rate clarification
Plate separators
Skimmers
Flotation systems
Sludge collectors
Adsorption clarifier-filter systems
Residuals ManagementSpent caustic, spent acid and
organicwaste management
Spent catalyst recovery
Biological TreatmentSequencing batch reactors
Select or plug flow reactors
Multi-channel and single-channel oxidation ditches
Surface aerators
Jet aerators
Fine and coarse bubble aeration
Mixers
Anaerobic
RBCs/SBCs
MBR (Membrane Bioreactor)
MBBR (Moving Bed Biofilm Reactor)
Trickling filters
Activated sludge systems andpackage plants
Biological aerator filters
Biotowers
Powdered activated carbon systems
GAC fluid beds
Media
Advanced fluidized composting
Biological nutrient removal
Monitoring and control
Filtration/PolishingConventional shallow and deep bedfilters
Upflow filters
Pulsed bed filters
As the world’s leading provider of industrial and municipal wastewater treatment,Siemens offers the most comprehensive solutions to our customers’ wastewatertreatment problems. From groundwater or landfill leachate treatment, tomunicipal wastewater or zero-discharge facilities, Siemens offers a total solutionsapproach to wastewater treatment, recovery and reuse. We have the widestrange of technologies, products and services to help you minimize operatingcosts, maximize resources and meet discharge requirements.
Siemens provides a complete range of technologies and services for wastewatertreatment industry, from pretreatment to effluent discharge and residualsmanagement:
213
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
BACK Main Table of Contents
WASTEWATER
Wastewater Capabilities
Traveling bridge filters
Multimedia filters
GAC fluid beds
Membrane filtration
Reverse osmosis
Activated carbon
Pressure filters
Filter underdrains
Micro-screens
Solids HandlingGravity thickeners
Aerobic and anaerobic digestion
Belt filter presses
Filter presses
Pasteurization
Sludge dryers
Composting
Wet air regeneration
Incineration
Sludge conveyance systems
Groundwater, Soil Remediation/Leachate Treatment
Media filters
Biological treatment
Clarification
Metals removal systems
Solids handling systems
Activated carbon systems
In-process TreatmentWet air oxidation
Metals removal
Coker clarifiers
Desalter oil/water separators
Selenium removal
Evaporation/crystallization
Ion exchange
UV oxidation
Strippers
Carbon adsorption
Resource RecoveryOil, glycol recovery systems
Metal recovery systems
Activated carbon recycling and
reactivation
Chemical recovery systems
Water reuse systems
Energy recovery systems
Ion exchange
Air/VOC/SO2 Treatment & RecoveryOdor control
Sulfur recovery
H2S removal
Activated carbon adsorbers
Emergency vapor scrubbers
VOC/odor containment covers
Gas collection and incineration
Support ServicesLaboratory analysis
Treatability and pilot plant studies
Startup and personnel training
Preventative maintenance contracts
Rehabilitation and retrofits
Service contracts
Outsourcing
Design-build-own-operate
Financing, leasing
Centralized treatmentResource recovery
For Additional Information on Our Wastewater Capabilities Contact:
Siemens Water Technologies
181 Thorn Hill Road
Warrendale, PA 15086
toll free 800.525.0658
telephone 724.772.1402
Main Table of Contents
This page intentionally left blank
BACK
BACK Main Table of Contents
Support Services
ACTIVATED CARBON TURNKEY SERVICESAdsorber Exchange Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216Analytical Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216Carbon Changeout Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216Reactivation and Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216
ENVIRONMENTAL SERVICESGroundwater Remediation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217Hazardous Waste Treatment and Recovery . . . . . . . . . . . . . . . . . . . . . .217Hydrocarbon Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218Wastewater Ion Exchange Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
ION EXCHANGE RESIN TURNKEY SERVICESReplacement Resin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219Resin Cleaning and Reconditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . .219Resin Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 Resin Transportation (Bulk) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220Turnkey Removal and Replacement Services . . . . . . . . . . . . . . . . . . . .220
MAINTENANCE AND OPERATING SERVICESBuild-Own-Operate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221Service Contracts and Preventative Maintenance . . . . . . . . . . . . . . . . .221Start-Up Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221Temporary Water Treatment Systems . . . . . . . . . . . . . . . . . . . . . . . . . .222
RO MEMBRANE TURNKEY SERVICESMembrane Care ProgramSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223Analytical Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223Off-Site Membrane Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223Replacement Membranes and Components . . . . . . . . . . . . . . . . . . . . .223 Chemical Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223
SPARE AND MANUFACTURERS’ ORIGINAL PARTSSpare Parts, Expendables and Consumables . . . . . . . . . . . . . . . . . . . .224Replacement Filtration Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224Manufacturers’ Original Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224Replacement Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225Water & Wastewater Data Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225
TECHNICAL SERVICESAnalytical Water Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226Application Engineering & Custom System Design . . . . . . . . . . . . . . . .226Audits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226Pilot Studies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226Project Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227System Optimization Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227NovaSys – Mechanical Upgrade Program . . . . . . . . . . . . . . . . . . . . . . .228Documentation and Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229
T A B L E O F
C O N T E N T S
215
216
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SUPPORT SERVICES
Activated Carbon Turnkey Services
Siemens Water Technologies is the single source for all your Granular Activated Carbonneeds. Our complete line of equipment and Westates® activated carbon products providesthe right solution for all your applications, whether industrial, municipal or environmental.We offer turnkey Services to ensure that your equipment continues to operate reliably andeconomically, while meeting regulatory requirements. From process evaluation andmodeling through design, fabrication and installation, to custom on-site service, Siemens hasthe financial stability and programs to manage your long-term risk.
ADSORBER EXCHANGE PROGRAMOffers a simple and cost effective way to handle your removable adsorber equipment tanks.When the adsorber has reached the end of its useful life and the activated carbon inside is“spent”, a local Siemens Water Technologies technician delivers fresh carbon tanks to yoursite. We can assist with the spent carbon profiling and acceptance procedures necessary fortimely removal and reactivation of your spent carbon. After our environmental departmentapproves the profile, we work with you to arrange for pick-up of the spent adsorber(s) andtransport to our reactivation facility.
ANALYTICAL TESTING Siemens operates a fully equipped carbon testing laboratory that uses ASTM, AWWA andinternally developed standard test methods to fully characterize virgin and spent activatedcarbons. Our laboratory has been certified as an environmental testing laboratoryapproved for testing hazardous solid wastes for ignitability, corrosivity, toxicitycharacteristics leaching procedures (TCLP), inorganic metals and organics in accordancewith appropriate EPA methods. Wastewater fields of testing include inorganic metals andorganics in accordance with EPA methods.
CARBON CHANGEOUT SERVICESFor systems that are permanent and hard-piped, Siemens offers turnkey carbon changeoutservices. Our service crew mobilizes on site to remove, package and label the spent carbon inDepartment of Transportation (D.O.T) approved containers. After removal, inspection of thevessel interior and internal distributors is conducted and minor repairs are made if necessary.The adsorber is refilled with fresh activated carbon and the spent carbon is transported to ourRCRA-permitted reactivation facility.
REACTIVATION AND RECYCLINGSiemens offers the most environmentally sound alternative to disposing of spentcarbon in landfills. Our RCRA-permitted reactivation facility recycles used carbonby processing it through a furnace system, removing and destroying inorganicimpurities. The recycled carbon exits the reactivation units, is cooled, tested forquality assurance and packaged for reuse. Lot numbers, sampled and analyzed inaccordance with Siemens' QA/QC program, identifies the reactivated carbon. Theentire state-of-the-art process is computer controlled and monitored, ensuring thefacility meets or exceeds federal and state regulatory requirements for air andwater discharges. A Certificate of Reactivation can be issued for each shipment ofrecycled carbon. This certifies that the spent carbon has been recycled in a mannerthat meets or exceeds all applicable RCRA and Benzene NESHAP regulations.
Other turnkey services include:• Design/Engineering • Carbon Canister Monitoring• Fabrication/Installation – Lic. Contractor • Benzene NESHAPS Monitoring• Mobilization/Removal of Equipment • Transportation• Dedicated Potable Water Vehicles
217
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SUPPORT SERVICES
Environmental Services
GROUNDWATER REMEDIATION SERVICESWater is our planet’s most valuable natural resource. Faced with the challenges ofincreasing populations, more stringent government standards and more complextreatment solutions, many municipalities and industries alike are faced with the growingchallenge of properly treating their contaminated wells, runoff and other groundwatersupplies. Siemens Water Technologies provides the technical know-how and has the cost-effective solutions to make treating contaminated waters – whether destined for potabledrinking water or non-potable discharge – simplified.
Siemens Environmental Services include reliable solutions for dealing with your mostdifficult contaminated waters issues. Our products and systems are based on the BestAvailable Technology (BAT) for treating a broad range of contaminants, including: • Arsenic• Chrome, Hexavalent chrome• Iron• Manganese• MTBE (Methyl tertiary-butyl ether)• Nitrates• Perchlorate• Radionuclides• TCE (Trichloroethylene)• VOC (Volatile organic compounds)
HAZARDOUS WASTE TREATMENT AND RECOVERYSiemens operates two, fully-permitted facilities with federal RCRA Part B and CERCLAauthority for the treatment and recovery of inorganic or trace organic waste. Wastes aresent to the facilities in drums (of all sizes), portable totes, cubic yard bags or boxes andtanker trucks. Virtually everything that we take into our facilities is in some way recycled.Facilities located in Roseville, Minnesota and Los Angeles, California serve as regionalhubs for the treatment of hazardous wastewater and the recovery of reusable byproducts.
Core industries for this service include:• Printed circuit board manufacturing• Metal finishing• Automotive• Aerospace• Semiconductor manufacturing• Parts washing• Groundwater cleanup• Environmental Contractors• General Industry
There are many other industrial wastes that may not be RCRA regulated, but still cannotbe discharged to sewer or local landfill. Boiler cleanout, low level metal rinsewaters, partswasher effluent, bag house dust or ammonia water are just a few examples of the varietyof non-regulated wastes also processed by Siemens.
Our goal is to produce zero hazardous waste by extracting all reusable material, toeliminate pollutants from the environment and avoid disposal costs and liability. Ouradvanced processing techniques have allowed us to increase beneficial reuse rate ofthese wastes to over 90% as reusable chemicals and metallic commodities.
218
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SUPPORT SERVICES
Environmental Services
HYDROCARBON SERVICESWhen waste generation can‘t be prevented, reuse and recycle are at the top of theEPA’s waste management best practices list. How these materials are managedmatters to both the customer and Siemens. Our hydrocarbon services businessprocesses and recycles oily wastes and contaminated water from both commercialand industrial customers. A broad range of treatment and recycling options helpsimplify our customers’ waste management needs and at the same time ensurescomplete environmental compliance and minimizes liability.
Services range from collection and recycling of used Glycol and antifreeze products,used oil filters, and used oil to oil-water separation and cleaning to emergencyresponse and spill support. While our business is regional, we service all types ofcustomers along the Atlantic seaboard down through the Gulf Coast.
WASTEWATER ION EXCHANGE SERVICEWastewater Ion Exchange (WWIX) is a service-based treatment approach for heavymetals control in dilute wastewater streams. We integrate equipment and serviceoption combinations to meet your discharge requirements, achieve the water qualitylevel needed for reuse while also minimizing your capital investment, reducingoverall space requirements and minimizing the liability associated with on-sitestorage and handling of chemicals.
Our Wastewater Ion Exchange (WWIX) systems use specially selected resins andmedias to remove soluble heavy metals from various manufacturing processes,cooling systems and contaminated groundwater. Each resin/media has a finitecapacity for metals removal. Once this capacity is reached, a Siemens field servicetechnician removes the exhausted tanks and replaces them with fresh tanks. Theexhausted resin/media is returned to our RCRA-permitted plant for regeneration andreuse. The byproducts of these regeneration processes are further subjected to ahigh temperature recovery process that captures the metals for reuse. All residualsare captured as individual metals or sold as part of an iron-rich material used in theproduction of Portland cement.
219
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SUPPORT SERVICES
Ion Exchange Resin Turnkey Services
REPLACEMENT RESIN
Choose USF™ Ion Exchange ResinAs a leader in resin technology, we noticed a trend toward inconsistent performanceand quality of resins available in the marketplace. Because of the process guaranteesSiemens Water Technologies offers, we are able to produce resins that meet morestringent, tighter resin performance specifications. Thus, USF™ ion exchange resin wasestablished to ensure our customers receive the highest quality product.
Advantages of Choosing USF™ Resin• We offer USF™ ion exchange resin at cost savings over equivalent products.• Our QA/QC program is ANSI N45.2, 10CFR50 Appendix B, and 10 CFR21
compliant to meet nuclear safety requirements.• We can provide process performance guarantees upon request.• Extensive technical support and resin application knowledge.
We provide Certificates of Analysis, Certificate of Conformance, and Shelf Lifestatements upon request.
RESIN CLEANING AND RECONDITIONING
Siemens Water Technologies provides services for salvaging your fouled, cross-contaminated and/or exhausted resin. We can remove resins, transport them to ourlocal processing plant, convert the resins and return them to your facility. This extendstheir useful life, minimizes costs and reduces system downtime. We can also do this ona scheduled basis for condensate polishing or other water treatment applications. Theresin can be transported to and from the job site in our tanker trucks, 55 gallon drums,lined fiber drums, or supersacks.
RESIN TESTING
To ensure optimum performance from your water treatment system, Siemensrecommends periodic testing of your ion exchange resin. Siemens' resin testing facilitycan determine resin quality, diagnose operating problems and evaluate new ionexchange products for conventional and special liquid processing applications. Our labcan perform the following tests on your resin samples.
Standard laboratory resin testing• Capacity before/after clean up steps• Percent moisture• Particles size • Iron Fouling• Microscopic visual examination
220
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SUPPORT SERVICES
Ion Exchange Resin Turnkey Services
Additional testing available• Percent conversion• Bead strength• Metallic impurities• Cross contamination• Kinetics (Mix Bed Test)• Kinetics (Mass Transfer)• TOC Extractables• 16 hour soak
RESIN TRANSPORTATION (BULK)
Siemens offers bulk delivery and disposal of resin. We eliminate drum handling byslurrying the resin directly from your water treatment service vessels to one of ourfleet of tanker trucks. Whether we’re delivering your own regenerated resin orproviding new resin, we greatly reduce the steps involved and the documentationand administrative controls that go with temporary on-site and off-site disposal ofresin.
TURNKEY REMOVAL AND REPLACEMENT SERVICES
When it’s time to remove and replace your existing resin, consider Siemens to handleyour needs on a full turnkey basis. Siemens’ team of trained professionals will providecomplete project coordination, from predisposal testing through new resininstallation to used resin landfill disposal or investment recovery (used resin brokers).We do it all. With complete responsibility in Siemens’ hands, you can be assured thatyour project will be completed on schedule, within budget and most importantly, infull compliance with all environmental regulations.
In addition to being the largest distributor of ion exchange resin, Siemens alsoprovides a full range of resin support services including laboratory testing, removal,cleaning and resin re-conditioning for extended life. We offer special handling,custom packaging or bulk delivery to meet your needs. If you are considering disposaland investment recovery options, we have the expertise to help.
• Dynamic
• Organic Cl, SO4 Extractables
• 16 hour soak (UV)
• Dynamic (UV)
• Parr Bomb
• Terminal Settling Velocity (TSV)
• Super Fines (-60 mesh)
221
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SUPPORT SERVICES
Maintenance and Operating Services
BUILD-OWN-OPERATE
Outsourcing water and wastewater treatment systems has been common over thepast 30 years. Because of the vast array of technologies and solutions available,more and more companies are handing this operation over to Siemens WaterTechnologies. We can provide and evaluate the right technological and economicsolutions, since our sole business is the operation of the entire treatment system.This ensures the lowest total treatment cost while insuring maximum on-lineoperation, guaranteed treated water quality, and the ability to quickly react tounforeseen circumstances. This allows you to focus on your core competency –making your product – while not using capital on projects that do not providerevenue. Companies that rely on outsourced services, however, still maintainstrategic control of their operations, both now and in the future.
SERVICE CONTRACTS AND PREVENTATIVE MAINTENANCESiemens offers you peace of mind with our custom service contracts andpreventative maintenance agreements. Extended equipment life and efficientoperation are direct benefits of selecting Siemens to maintain your water treatmentequipment.
Our service contracts are custom tailored to help you get the most value from yourwater treatment equipment investment. The Siemens Water Technologies servicetemplate is customized for your equipment and operating parameters. If yourequipment is not operating in the normal range, our custom service template willflag it immediately. A follow up letter is sent detailing the condition, correctiveaction, maintenance requirements, and potential complications if the condition isignored. This system provides an expert evaluation of your equipment operation ona regular basis.
In some cases you may chose to have Siemens perform the necessary maintenancetasks to extend your equipment life. We offer custom preventative maintenanceservices as part of our service contracts. We include services such as filter re-bedding,ion exchange re-bedding, RO membrane cleaning, and parts replacement such aspump seals, UV bulbs, and cartridge filters. A customized contract allows you to decidethe level and frequency of service that is best for your facility.
Our factory-trained service technicians are ready to serve you from over 80 officesin North America. Our localized service allows us to schedule service and repairswhen you need them. Our local service structure allows us to have fast emergencyresponse and parts availability when you need it. Contact your local branch for aservice evaluation for your plant today.
START-UP SERVICE
Siemens can provide a team of process experts to assist with your systeminstallation and bringing your system on line. Our factory/field project team willassist you with filling all tanks and equipment with production feedwater,monitoring the process through several production cycles and show yourproduction personnel all the process adjustments needed to be sure you’re gettingthe product water you expect.
222
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SUPPORT SERVICES
Maintenance and Operating Services
We can also provide complete turnkey service. After defining your processparameters, we will configure the most cost-efficient system, install the equipment,fully test the process, train your personnel and provide guarantees regarding productwater. Many companies find this minimizes the demands on their own resources andpersonnel.
TEMPORARY WATER TREATMENT SYSTEMSFor over 30 years, Siemens has met the short-term and emergency treated waterneeds of our customers using our mobile water treatment systems.
Units may be installed in your plant and operated as stand-alone units or installedinside a trailer and controlled by the system panel. Units can be combined with otherSiemens products to assemble fully integrated water treatment systems designed tocustomers’ specific treated water quality and flow needs.
MOBILE SYSTEMS INCLUDE:• FlexRO® – Skid-mounted, self-contained, 100 gpm reverse osmosis units that
feature 3:2:1 (4M) array skids. • FlexTrex® – Skid-mounted ion exchange units that are designed to treat flows
ranging from 20 to 250 gpm per unit. Regenerated off-site, these portable unitsdo not use hazardous chemicals, do not generate wastewater and are ideal forpolishing raw or RO permeate water.
• PreFlex® – Units are modular in design, pre-plumbed, self-contained, skid-mounted pretreatment units. They are designed to the highest engineeringstandards with ASME code tanks, NEMA 4X panels and pneumatically actuatedsolenoid valves enabling them to be used in a wide variety of applications andenvironments including heavy industry.
• Mobile Clarifier Trailers – Self-contained, trailer-mounted system capable oftreating highly turbid water (>1000 NTU). The system is capable of producingextraordinarily clear effluent (0.5-1.0 NTU) with remarkable stability undervarying raw water conditions. Flow rates to 1,050 gpm.
• Mobile Demineralizer (DI) Trailers – These trailers are the treatment of choicefor zero-discharge applications and seasonal treated water needs. Withregeneration facilities across the country and a large fleet of over 80 servicebranches, Siemens can respond quickly to your emergency treated water needs.
• Mobile RO (Reverse Osmosis) Trailers – Self-contained, trailer-mountedsystems that can be configured with combinations of 4 skid-mounted FlexRO-100 units. Systems have flow rates up to 400 gpm per trailer.
TYPICAL USES:
• Facility expansions
• Pilot plant water needs
• Interim use until a permanent system is installed
• Process water/treated water quality changes
• Environmental salt discharge problems
• Emergency/scheduled shutdowns
• Seasonal water needs
223
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SUPPORT SERVICES
RO Membrane Turnkey Services
MEMBRANE CARESM PROGRAMOur Membrane CareSM Program provides the services to keep your reverse osmosis (RO)system operating at peak performance. In addition to our large inventory ofmembranes and replacement parts, our trained service technicians can provideassistance with membrane removal and installation or membrane cleaning, either on-site utilizing your clean-in-place skid or off-site at one of our regional cleaning facilities.We offer membrane autopsies and complete laboratory services to evaluate systemperformance and improve productivity.
ANALYTICAL SERVICESSiemens’ analytical testing includes feedwater and outlet water analyses and variousmembrane analytical techniques. Our Membrane Center of Excellence can providefeed, concentrate and permeate water analyses, SDI pad analyses and various non-destructive and destructive tests. Membrane analysis assists in identifying the foulingagent(s), proper cleaning techniques and proper pretreatment methods to preventrecurring fouling.
OFF-SITE MEMBRANE CLEANINGSiemens’ off-site cleaning process is specifically designed to restore RO membranes toor near the original manufacturer’s performance specifications. Our proprietaryequipment and strict cleaning process are tightly controlled to ensure optimumcleaning performance, resulting in longer intervals between cleanings and/orreplacement. The cleaning process does not affect the structural integrity of themembrane and, therefore, does not void the manufacturer’s warranty. Siemens WaterTechnologies offers three levels of off-site cleaning service for your 4” and 8” elements.
REPLACEMENT MEMBRANES AND COMPONENTSSiemens is your leading source for replacement membranes. We supply elements from allof the major manufacturers. For your convenience, we inventory FILMTEC™ andHydranautics® membranes at our seven regional distribution facilities. This enables us tomeet short lead times and thereby minimize your system’s downtime. In addition, ourregional distribution facilities also stock major components, such as replacement gauges,pumps and end caps.
CLEANING CHEMICALSSiemens can determine the source of your membrane fouling problem and makerecommendations on the selection and purchase of proper chemical treatments and, ifnecessary, appropriate pretreatment steps. Our broad membrane system expertise enablesus to provide reliable diagnosis methods and sound troubleshooting to return yourequipment to optimum performance. We work with all the RO chemical manufacturers andprovide you with the best combination of RO antiscalants, chemical feed systems anddosing rates to keep your RO system running smoothly.
224
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SUPPORT SERVICES
Spare and Manufacturers’ Original Parts
SPARE PARTS, EXPENDABLES & CONSUMABLES (Filter Cartridges, UV Bulbs, Gaskets, Nuts, Bolts, Piping)
We have the largest inventory of spare and replacement parts in the industry. If youneed filter elements, UV components, replacement gauges or controls, we stock theseas well as other parts. We supply both industrial grade products and validatedpharmaceutical bacteria-removal cartridges.
We have filter housings for every purpose, from simple plastic construction to anelectro-polished, sanitary pharmaceutical design. Our complete line of sterilizersdeliver flows of 1 gpm to 1,000 gpm. These systems can be designed to reducebacterial contamination and destroy TOC (total organic carbon) materials in the supplywater.
We also provide replacement and spare parts for your ancillary system components,such as pumps, valves and gaskets. Whether it involves normal wear-and-tearreplacement, maintenance or spares inventory, we will help ensure your watertreatment systems operate efficiently with minimal downtime.
REPLACEMENT FILTRATION MEDIA
We offer a wide variety of filtration medias and underbedding materials for everyfiltration application. These include sand, garnet, gravel, anthracite or quartz materialsscreened to the specific mesh sizes required. We also offer media removal, vessel anddistribution inspection, installation of the new media plus disposal of the spent mediaif required.
MANUFACTURERS’ ORIGINAL PARTS
We provide components for equipment names you are familiar with in the Siemensfamily, including Illinois Water Treatment (IWT®), Permutit®, L*A Water, Kisco™,Ionpure® and Polymetrics™, to name a few. From vessel replacements to internals andPermutit multiport valves, Siemens is the only company that can ensure the parts youbuy are designed and engineered to fit your original equipment. Our library of originalinstallation drawings ensures all replacement components are completely compatiblewith existing systems.
CALL THE NUMBER BELOW TO ORDER PARTS FOR EQUIPMENT MADE BY THESE SIEMENSCOMPANIES.
Arrowhead® Industrial Water 1-800-875-7873 ext. 5000Continental® 1-800-875-7873 ext. 5000Interlake 1-800-875-7873 ext. 5000Ionpure® 1-800-875-7873 ext. 5000IWT® (Illinois Water Treatment) 1-800-582-5261Kisco™ 1-800-582-5261L*A Water 1-800-582-5261Mitco 1-800-875-7873 ext. 5000Penfield® 1-800-875-7873 ext. 5000Permutit® 1-800-631-0878 ext. 107, 108 Polymetrics™ 1-800-875-7873 ext. 5000Water Services of America 1-800-875-7873 ext. 5000
225
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SUPPORT SERVICES
Manufacturers’ Original Parts
MANUFACTURERS’ ORIGINAL PARTS SPECIALIZED OR PROPRIETARY ITEMSREPLACEMENT TANKS (PRESSURIZED AND ATMOSPHERIC) VESSEL REPAIRS AND UPGRADES
Whether it is a system supplied by Siemens, a legacy company or any/all other watertreatment manufacturers, we can assist you with specialized or proprietary itemsincluding:
Some of the tanks, vessels and vessel repairs that we can provide:
For additional information, call 800.582.5261 ext. 378.
PERMUTIT® WATER AND WASTEWATER TREATMENT DATA BOOK
As advertised for years by Permutit, “We wrote the book on water treatment”. Thelatest edition of this popular, 166-page engineering data book contains charts, graphsand illustrations for general water data, pipes and fittings, chemical properties anddata, and waste treatment information. The book is a useful tool for all individualsinvolved in the design of water and wastewater treatment systems, pollution controland water recovery and reuse. To order copies or for additional information, contact 1-800-631-0878, ext. 107, 108.
• Bushings
• Chevron tube settlers
• Desiccant breathers/fume vents –
including designs using dyed resins
• Distribution systems – complete
systems or individual components
• Face piping
• Gauge glasses
• Inlet diffusers
• Level switches
• Nozzles – conventional, dual velocity,
spray, etc.
• Overflow controls/traps
• Packing for deaerating heaters,
decarbonators, degasifiers, etc.
• Pillow blocks
• Pressure gauges
• Rotary surface washers
• Rupture disks
• Shafts
• Sampling devices/sinks
• Sight windows
• Socket agitator arms
• Strainers and strainer baskets –
conventional, dual velocity, specialty,
underdrain, etc. – including
polystyrene, PVC and stainless steel
construction
• Thermometers
• Vacuum breakers
• Valve inspection and repair
• Valve retrofits – manual to automatic
• Valves, maintenance kits and parts –
inlet, control, pressure relief, spray,
multiport, etc.
• Vent condensers
• ASME code and non-code designs
• Chemical regeneration tanks (acid,
caustic and brine)
• Custom designed tanks
• Double dish design
• Exact replacements
• Fiberglass tanks
• Flat false bottom vessels
• Replacement tanks for neutralization
systems
• Replacing tank liners on-site
• Spray lined and rubber lined vessels –
including FDA compliant linings
• Storage tanks
226
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SUPPORT SERVICES
Technical Services
ANALYTICAL WATER TESTING Before you can select the right combination of technologies to deliver the level ofwater quality that you need, it is essential to know exactly what is in your water.Siemens' analytical testing laboratory offers complete testing services to determinethe most appropriate system components to meet each customer’s particularapplication needs. The water analysis and research and development laboratoriesconduct a wide range of tests designed to accommodate the analysis of water forall applications, including pharmaceuticals, high-purity water, hemodialysis,laboratory, pretreatment and troubleshooting. The laboratory has the capacity toperform inorganic analysis and TOC testing. We offer postage-paid water analysistest kits designed to address a variety of field requirements. Once a test kit isreturned to the lab, we tailor the testing and reporting to meet specific customerrequirements. Comprehensive reports are generated and the laboratory maintainsan extensive database.
APPLICATION ENGINEERING & CUSTOM SYSTEM DESIGN
Siemens offers customized water treatment systems in addition to standard, pre-engineered products. The scope of our involvement in a project is determined bythe needs of the customer, the types of technologies being evaluated and thecomplexity of the treatment solution being considered. Designers, drafters andengineers in our CAD/CAE (computer-aided design/computer-aided engineering)group work together with manufacturing, R&D and sales personnel to developequipment and system designs for a broad scope of treatment needs. They haveextensive experience in process water filtration and CAD/CAE, with specificexpertise in piping design, process instrumentation, steel weldment fabrication,tooling, electrical design, panel layout and programming. When you need acontinuous supply of high-purity water for your critical application, consult with ourwater treatment experts to determine the most effective and efficient system tocontinuously and consistently meet those needs.
AUDITS
One of the many services Siemens offers to help customers manage their water andwastewater treatment are plant audits. These completely confidential audits,conducted by our specially trained audit teams, help customers solve a specificproblem or improve their plant operations.
PILOT STUDIES
We offer process water and wastewater treatment pilot systems representingvarious technologies so you can test the technology on your application before youbuy. Among our pilot plant capabilities is the industry’s most complete test facilityfor biological processes and aeration, the world’s only complete wet air oxidationplant and equipment for testing dewatering processes, pumping and filtrations.Many of our pilot facilities are trailer or skid-mounted, so you can test variousprocesses on your wastewater at your site – under operating conditions.
227
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SUPPORT SERVICES
Technical Services
PROJECT MANAGEMENTEach water or wastewater treatment system we manufacture and install is projectmanaged by an expert focused on the needs of your industry. From initial problemanalysis to system start-up, we’ll work with your team to ensure a successful treatmentproject that meets your requirements. Our biopharmaceutical design/build and programmanagement group offers design/build capabilities; pre-engineered/modular constructedequipment and process systems (skid) applications. We also offer turnkey projectmanagement.
SYSTEM OPTIMIZATION PROGRAMFor existing water treatment systems that are not operating at optimum efficiency,Siemens offers the System Optimization Program to enhance system performance. Theprogram is offered through Siemens' Engineered Parts and Services (EP&S) group.Through the program, an EP&S Technical Services Engineer will:• Travel to the site.• Conduct a comprehensive review of the water treatment system and ancillary
equipment.• Meet with operating personnel to determine current maintenance procedures and
operating conditions.• Review operating data and sequences, drawings and operating and maintenance
manuals.• Provide a detailed engineering report, including observations and recommendations.
Services are available on a per diem basis and can include engineering consulting, processtroubleshooting, equipment evaluation and optimization and an optional ProcessOptimization Modeling Report. Using Siemens' WinCPD® proprietary computer simulationprogram, a Process Optimization Modeling Report will be generated. Allowing a multitudeof variables withing the water treatment system to be analyzed, the WinCPD® program wilthem model the most effective operating parameters for the system. The programincludes water treatment systems supplied through Siemens' family of companiesincluding systems previously supplied by:
• Continental® Water Systems Corporation • L*A Water• Himsley Engineering Ltd./Himsley International • Mitco• Interlake Water Systems Company • Penfield®• Ionpure® • Permutit®• Illinois Water Treatment (IWT®) • Polymetrics®• Kisco® • Water Services of America
We are also well qualified to perform evaluations on water treatment systems supplied byall other manufacturers. For additional information, call 800.582.5261 ext. 342 or 340.
228
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
SUPPORT SERVICES
Technical Services
NOVASYS – MECHANICAL UPGRADE PROGRAMAfter years of usage, a water treatment system may be showing signs ofdeterioration. The vessel or piping may be corroded or leaking or variouscomponents may not be functioning properly. In other instances, the technologymay have changed offering better efficiencies.
Through NovaSys, one of our inspectors will travel to the site, perform a thoroughsystem analysis and submit a detailed list of recommendations. Suggestions foralternative materials of construction and/or designs will be included within therecommendations to reduce costs and improve safety and operating efficiencies.
As part of the program, we can replace worn or outdated:• Tanks (repairs are also available)• Piping manifolds• Internals and other distribution systems• Valves, strainers, pumps and other components• Resins and other media
We will also offer recommendations for upgrading the system. Typical NovaSysupgrades that we supply include:
• Changing conventional downflow softeners and two bed deionizers (also calledseparate beds) into highly efficient packed bed systems
• Upgrading internal tank distribution systems for greater reliability• Using Siemens' patented Heat Optimized Technology (HOT Series) to transform
typical carbon towers into hot water sanitizable carbon filters to control effluentbiological growth
• Upgrading regeneration chemical skids (pumped or educted systems) forimproved performance
Some of the advantages of Siemens' NovaSys Mechanical Upgrade Program include:• Improves safety by minimizing burst and leak risks• Eliminates downtime for increased productivity• Provides consistent water quantity and quality• Saves costs because less chemicals are consumed• Improves pump performance for better chemical utilization• Corrects dosages and flow rates for improved regeneration times• Reduces maintenance labor and parts• Reduces utility costs through reduced water usage
For additional information, call 800.582.5261 ext. 340.
229
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
SUPPORT SERVICES
Technical Services
DOCUMENTATION AND VALIDATION
Siemens understands that process validation of the entire water treatment system isan important concern, and often a hidden cost, to our pharmaceutical customers.That’s why we offer systems that are designed with validation in mind. These systemsincorporate proven equipment components and instrumentation that makes datemonitoring more convenient for systems operators. We regularly install programmablelogic control (PLS) validated systems that continuously and automatically monitor andrecord critical parameters. We offer a full range of validation support documents withour pharmaceutical and biotechnology system designs. We also provide copies of ourdocumented, established quality control procedures for hemodialysis reverse osmosiswater systems and hemodialysis resin regeneration centers.
Section Table of Contents
This page intentionally left blank
BACK
BACK Main Table of Contents
Water Quality Standards, Constants,Conversions & Physical Data
REFERENCE INFORMATION TABLES
Conductivity and Resistivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
ASTM Reagent Water. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Clinical Laboratory Standards Institute. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
USP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
AAMI Hemodialysis Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
U.S. Boiler Feedwater Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
Langelier Saturation Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
Calcium Carbonate Equivalents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
Equivalents of
Liquid Measures and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Pressure and Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Centigrade (°C) to Fahrenheit (°F). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Tank Areas and Volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
A Key to Relative Particle Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Velocity of Liquids in Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
T A B L E O F
C O N T E N T S
231
Main Table of Contents
Siemens Water Technologies24-hr Customer Service: 800.466.7873
This page intentionally left blank
BACK
Section Table of ContentsBACK
233233REFERENCE TABLES
Conductivity and Resistivity (CaCO3 solutions at 25°C)
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Conductivity Resistivity Dissolved Solids Grains/Gallon(micromhos-cm) (ohms-cm) (parts per million) (as CaCO3)
(as CaCO3)
0.056 18,000,000 0.0277 0.001640.059 17,000,000 0.0294 0.001700.063 16,000,000 0.0313 0.001810.067 15,000,000 0.0333 0.001930.072 14,000,000 0.0357 0.002110.077 13,000,000 0.0384 0.002220.084 12,000,000 0.0417 0.002400.091 11,000,000 0.0455 0.002630.100 10,000,000 0.0500 0.002920.111 9,000,000 0.0556 0.003220.125 8,000,000 0.0625 0.003680.143 7,000,000 0.0714 0.004150.167 6,000,000 0.0833 0.004850.200 5,000,000 0.100 0.005850.250 4,000,000 0.125 0.007310.333 3,000,000 0.167 0.009710.500 2,000,000 0.250 0.01461.00 1,000,000 0.500 0.02921.11 900,000 0.556 0.03221.25 800,000 0.625 0.03681.43 700,000 0.714 0.04151.67 600,000 0.833 0.04852.00 500,000 1.00 0.05852.50 400,000 1.25 0.07313.33 300,000 1.67 0.09715.00 200,000 2.50 0.146
10.0 100,000 5.00 0.29211.1 90,000 5.56 0.32212.5 80,000 6.25 0.36814.3 70,000 7.14 0.41516.7 60,000 8.33 0.48520.0 50,000 10.0 0.58525.0 40,000 12.5 0.73133.0 30,000 16.7 0.97150.0 20.000 25.0 1.46
100.0 10,000 50.0 3.22111.0 9,000 55.6 3.22125.0 8,000 62.5 3.68143.0 7,000 71.4 4.15167.0 6,000 83.3 4.85200.0 5,000 100.0 5.85250.0 4,000 125.0 7.31333.0 3,000 167.0 9.71500.0 2,000 250.0 14.6
1000.0 1,000 500.0 29.2
Conversions
Resistivity/Conductivity Total Dissolved Solids
ohm-cm = ___1_____ = _____1____ 1 grain per gallon = 17.1 parts per million (ppm)mho/cm Siemens/cm 1 part per million = 1 milligram per liter (mg/l)
234
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REFERENCE TABLES
ASTM® Reagent Water SpecificationsCLSI® (formerly NCCLS) Reagent WaterSpecificationsUSP® 30 Pharmaceutical Grade Water Standard
UNITED STATES PHARMACOPOEIA 30 STANDARDS
USP 30 Pharmaceutical Grade Water
Organics . . . . . . . . . . . . . . . . . . . . . . . . . . <0.5 ppm TOC
Conductivity . . . . . . . . . . . . . . . . . . . . . . . <1.3 µS/cm at 25°C in-line measurement**
Endotoxin by LALPurified Water . . . . . . . . . . . . . . . . . . . . No specificationWFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . <0.25 EU/mL
Bacteria (guideline only)Purified Water . . . . . . . . . . . . . . . . . . . . <100 cfu/mLWFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . <10 cfu/100 mL
**from equivalent values from USP Table for Conductivity Limits as a Function of Temperature.
CLSI(CLINICAL LABORATORY STANDARDS INSTITUTE)*
Clinical Laboratory Reagent Water (CLRW)
CLSI
Resistivity @ 25°C . . . . . . . . . . . . . . . . . . . . . . . . . 10(megohms-cm)
Conductivity @ 25°C . . . . . . . . . . . . . . . . . . . . . . . 0.1(micromhos/cm)
Bacterial Growth (cfu/mL) . . . . . . . . . . . . . . . . . . . . 10Organics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <500 ppb
a
Particulate Matter . . . . . . . . . . . . . . . . . . . . . . . . . . 0.22 µm Filtera
aThis specification is a process specification, and not measured by the end-user.
*Formerly NCCLS (National Committee for Clinical Laboratory Standards).
AMERICAN SOCIETY FOR TESTING AND MATERIALS
Standard Specifications for Reagent WaterASTM Type I II III IV
Conductivity @ 25°C (micromhos/cm) . . . . . . . . . . 0.056 . . . . . . 1.0 . . . . . . . 0.25 . . . . . . . . 5.0Resistivity @ 25°C (Megohms-cm). . . . . . . . . . . . . 18 . . . . . . . . . 1.0 . . . . . . . 4.0 . . . . . . . . . 0.2Total Silica (µg/L) . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . 3. . . . . . . . . 500 . . . . . . . . . . –Total Organic Carbon (µg/L) . . . . . . . . . . . . . . . . . . 100 . . . . . . . . . 50. . . . . . . . . 200 . . . . . . . . . . –Chlorides (µg/L) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . 5. . . . . . . . . 10 . . . . . . . . . . 50Sodium (µg/L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . 5. . . . . . . . . 10 . . . . . . . . . . 50pH* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – . . . . . . . . . –. . . . . . . . . – . . . . . . . . . . 5.0-8.0
Type A Type B Type C
Max Heterotropic Bacteria Count . . . . . . . . . . . . . . 10/1000 mL. . . 10/100 mL . . . 100/10 mLEndotoxin, EU/mL . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.03 . . . . . . . 0.25 . . . . . . . . N/A
*The measurement of pH in Type I, II, and III reagent water has been eliminated because these grades of water do notcontain constituents in sufficient quantity to alter pH.
235
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
REFERENCE TABLES
Association for the Advancement ofMedical Instrumentation(AAMI)Hemodialysis Water Quality
Contaminant
Aluminum. . . . . . . . . . . . . . . . . . . . 0.01Antimony . . . . . . . . . . . . . . . . . . . . 0.006Arsenic. . . . . . . . . . . . . . . . . . . . . . 0.005Barium . . . . . . . . . . . . . . . . . . . . . . 0.10Beryllium . . . . . . . . . . . . . . . . . . . . 0.0004Cadmium . . . . . . . . . . . . . . . . . . . . 0.001Calcium . . . . . . . . . . . . . . . . . . . . . 2 (0.1 mEq/L)Chloramines. . . . . . . . . . . . . . . . . . 0.10Chromium . . . . . . . . . . . . . . . . . . . 0.014Copper . . . . . . . . . . . . . . . . . . . . . . 0.10Fluoride . . . . . . . . . . . . . . . . . . . . . 0.20Free Chlorine . . . . . . . . . . . . . . . . . 0.50Lead. . . . . . . . . . . . . . . . . . . . . . . . 0.005 Magnesium . . . . . . . . . . . . . . . . . . 4 (0.3 mEq/L)Mercury . . . . . . . . . . . . . . . . . . . . . 0.0002Nitrate (as N) . . . . . . . . . . . . . . . . . 2.00Potassium . . . . . . . . . . . . . . . . . . . 8 (0.2 mEq/L)Selenium . . . . . . . . . . . . . . . . . . . . 0.09Silver . . . . . . . . . . . . . . . . . . . . . . . 0.005Sodium. . . . . . . . . . . . . . . . . . . . . . 70 (3.0 mEq/L)Sulfate . . . . . . . . . . . . . . . . . . . . . . 100.00Thallium . . . . . . . . . . . . . . . . . . . . . 0.002Zinc . . . . . . . . . . . . . . . . . . . . . . . . 0.10
a) The physician has the ultimate responsibility for ensuring the qualityof water used for dialysis.b) Unless otherwise noted.
Maximum Concentration(mg/L)b
Maximum allowable chemical contaminant levels in water used toprepare dialysate and concentrates from powder at a dialysis facilityand to reprocess dialyzers for multiple usea.
Water Bacteriology/EndotoxinsProduct water used to prepare dialysate or concentrates from powder at adialysis facility, or to reprocess dialyzers for multiple use, should contain atotal viable microbial count of less than 200 CFU/mL and an endotoxinconcentration of less than 2 EU/mL. The action level for the total viablemicrobial count in the product water shall be 50 EU/mL and the actionlevel for the endotoxin concentration shall be 1 EU/mL. If these actionlevels are observed in the product water, corrective measures, such asdisinfection and retesting, shall be taken promptly to reduce the levels toan acceptable range.
236
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REFERENCE TABLES
Boiler Feedwater Requirements
U.S. BOILER FEEDWATER REQUIREMENTS
Boiler H.P. gpm pound/hour
50 . . . . . . . . . . . . 4 . . . . . . . . . . . . . 1,72575 . . . . . . . . . . . . 5 . . . . . . . . . . . . . 2,587
100 . . . . . . . . . . . . 7 . . . . . . . . . . . . . 3,450150 . . . . . . . . . . . . 10 . . . . . . . . . . . . . 5,175175 . . . . . . . . . . . . 12 . . . . . . . . . . . . . 6,037200 . . . . . . . . . . . . 14 . . . . . . . . . . . . . 6,900225 . . . . . . . . . . . . 16 . . . . . . . . . . . . . 7,762250 . . . . . . . . . . . . 17 . . . . . . . . . . . . . 8,625275 . . . . . . . . . . . . 19 . . . . . . . . . . . . . 9,847300 . . . . . . . . . . . . 21 . . . . . . . . . . . . . 10,350350 . . . . . . . . . . . . 24 . . . . . . . . . . . . . 12,075400 . . . . . . . . . . . . 28 . . . . . . . . . . . . . 13,800500 . . . . . . . . . . . . 34 . . . . . . . . . . . . . 17,250750 . . . . . . . . . . . . 53 . . . . . . . . . . . . . 25,875
1,000 . . . . . . . . . . . . 69 . . . . . . . . . . . . . 34,5001,500 . . . . . . . . . . . . 104 . . . . . . . . . . . . . 51,7502,000 . . . . . . . . . . . . 138 . . . . . . . . . . . . . 69,0002,500 . . . . . . . . . . . . 172 . . . . . . . . . . . . . 86,2503,000 . . . . . . . . . . . . 207 . . . . . . . . . . . . . 103,5004,000 . . . . . . . . . . . . 276 . . . . . . . . . . . . . 138,0004,500 . . . . . . . . . . . . 310 . . . . . . . . . . . . . 155,2505,000 . . . . . . . . . . . . 345 . . . . . . . . . . . . . 172,500
10,000 . . . . . . . . . . . . 689 . . . . . . . . . . . . . 345,00015,000 . . . . . . . . . . . . 1,034 . . . . . . . . . . . . . 517,50020,000 . . . . . . . . . . . . 1,387 . . . . . . . . . . . . . 690,00025,000 . . . . . . . . . . . . 1,723 . . . . . . . . . . . . . 862,50035,000 . . . . . . . . . . . . 2,413 . . . . . . . . . . . . . 1,207,50040,000 . . . . . . . . . . . . 2,759 . . . . . . . . . . . . . 1,380,00045,000 . . . . . . . . . . . . 3,102 . . . . . . . . . . . . . 1,550,00050,000 . . . . . . . . . . . . 3,447 . . . . . . . . . . . . . 1,725,00060,000 . . . . . . . . . . . . 4,136 . . . . . . . . . . . . . 2,070,00080,000 . . . . . . . . . . . . 5,515 . . . . . . . . . . . . . 2,760,000
100,000 . . . . . . . . . . . . 6,894 . . . . . . . . . . . . . 3,450,000
Notes:• gpm is given to the nearest whole number• The above water quantities are based on 34.5 lb. of water evaporated per
hour at 212°F. The weight of 1 gallon of water is taken as being equal to8.34 lb. at 60°F. Intermediate water quantities in gpm are obtainable bymultiplying the boiler horsepower by 0.069.
• In selecting boiler feed pumps, the fact that boilers are often run 200 or300 percent of rating should be taken into consideration. The above figuresare of the actual boiler horsepower developed.
• Boiler feed pumps should have pressure in excess of the boiler ratedpressure in order to compensate for frictional losses, entrance losses,regulating valve losses and normal static head. These should be specifiedfor a particular installation. However, for estimating purposes, the followingvalues apply.
Boiler Pressure Feed Pump Discharge Pressure200 psi. . . . . . . . . . . . . . . 250 psi400 psi. . . . . . . . . . . . . . . 475 psi800 psi. . . . . . . . . . . . . . . 925 psi1,200 psi . . . . . . . . . . . . . 1,350 psi
237
Section Table of ContentsBACK
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
REFERENCE TABLES
Langelier (CaCO3) Saturation Index(Based on the Langelier Formula: Larson-Buswell: Residue-Temperature- Adjustments: Arrangedby Nordell)
TABLE B: Temperatures in °F
UnitsTens 0 2 4 6 8
30 2.60 2.57 2.54 2.5140 2.48 2.45 2.43 2.40 2.3750 2.34 2.31 2.28 2.25 2.2260 2.20 2.17 2.14 2.11 2.0970 2.06 2.04 2.03 2.00 1.9780 1.95 1.92 1.90 1.88 1.8690 1.84 1.82 1.80 1.78 1.76
100 1.74 1.72 1.71 1.69 1.67110 1.65 1.64 1.62 1.60 1.58120 1.57 1.55 1.53 1.51 1.50130 1.48 1.46 1.44 1.43 1.41140 1.40 1.38 1.37 1.35 1.34150 1.32 1.31 1.29 1.28 1.27160 1.26 1.24 1.23 1.22 1.21170 1.19 1.18 1.17 1.16
TABLE A: Total Solids/ppm
ppm
50 0.0775 0.08
100 0.10150 0.11200 0.13300 0.14400 0.16600 0.18800 0.19
1000 0.202000 0.233000 0.254000 0.265000 0.266000 0.28
TABLE C:Calcium Hardness Expressed as ppm CaCO3(for 3 to 209 ppm CaCO3, use upper table; for 210 to 990 ppm CaCO2, use lower table)
UnitsTens 0 1 2 3 4 5 6 7 8 9
0 0.08 0.20 0.30 0.38 0.45 0.51 0.5610 0.60 0.64 0.68 0.72 0.75 0.78 0.81 0.83 0.86 0.8820 0.90 0.92 0.94 0.96 0.98 1.00 1.02 1.03 1.05 1.0630 1.08 1.09 1.11 1.12 1.13 1.15 1.16 1.17 1.18 1.1940 1.20 1.21 1.23 1.24 1.25 1.26 1.26 1.27 1.28 1.2950 1.30 1.31 1.32 1.33 1.34 1.34 1.35 1.36 1.37 1.3760 1.38 1.39 1.39 1.40 1.41 1.42 1.42 1.43 1.43 1.4470 1.45 1.45 1.46 1.47 1.47 1.48 1.48 1.49 1.49 1.5080 1.51 1.51 1.52 1.52 1.53 1.53 1.54 1.54 1.55 1.5590 1.56 1.56 1.57 1.57 1.58 1.58 1.58 1.59 1.59 1.60
100 1.60 1.61 1.61 1.61 1.62 1.62 1.63 1.63 1.64 1.64110 1.64 1.65 1.65 1.66 1.66 1.66 1.67 1.67 1.67 1.68120 1.68 1.68 1.69 1.69 1.70 1.70 1.70 1.71 1.71 1.71130 1.72 1.72 1.72 1.73 1.73 1.73 1.74 1.74 1.74 1.75140 1.75 1.75 1.75 1.76 1.76 1.76 1.77 1.77 1.77 1.78150 1.78 1.78 1.78 1.79 1.79 1.79 1.80 1.80 1.80 1.80160 1.81 1.81 1.81 1.81 1.82 1.82 1.82 1.82 1.83 1.83170 1.83 1.84 1.84 1.84 1.84 1.85 1.85 1.85 1.85 1.85180 1.86 1.86 1.86 1.86 1.87 1.87 1.87 1.87 1.88 1.88190 1.88 1.88 1.89 1.89 1.89 1.89 1.89 1.90 1.90 1.90200 1.90 1.91 1.91 1.91 1.91 1.91 1.92 1.92 1.92 1.92
TensHundreds 0 10 20 30 40 50 60 70 80 90
200 1.92 1.94 1.96 1.98 2.00 2.02 2.03 2.05 2.06300 2.08 2.09 2.11 2.12 2.13 2.15 2.16 2.17 2.18 2.19400 2.20 2.21 2.23 2.24 2.25 2.26 2.26 2.27 2.28 2.29500 2.30 2.31 2.32 2.33 2.34 2.34 2.35 2.36 2.37 2.37600 2.38 2.39 2.39 2.40 2.41 2.42 2.42 2.43 2.43 2.44700 2.45 2.45 2.46 2.47 2.47 2.48 2.48 2.49 2.49 2.50800 2.51 2.51 2.52 2.52 2.53 2.53 2.54 2.54 2.55 2.55900 2.56 2.56 2.57 2.57 2.58 2.58 2.58 2.59 2.59 2.60
TABLE D:Alkalinity Expressed as ppm CaCO3(for 1 to 209 ppm CaCO3, use upper table; for 210 to 990 ppm CaCO2, use lower table)
UnitsTens 0 1 2 3 4 5 6 7 8 9
0 0.00 0.30 0.48 0.60 0.70 0.78 0.85 0.90 0.9510 1.00 1.04 1.08 1.11 1.15 1.18 1.20 1.23 1.26 1.2920 1.30 1.32 1.34 1.36 1.38 1.40 1.42 1.43 1.45 1.4630 1.48 1.49 1.51 1.52 1.53 1.54 1.56 1.57 1.58 1.5940 1.60 1.61 1.62 1.63 1.64 1.65 1.66 1.67 1.68 1.6950 1.70 1.71 1.72 1.72 1.73 1.74 1.75 1.76 1.76 1.7760 1.78 1.79 1.79 1.80 1.81 1.81 1.82 1.83 1.83 1.8470 1.85 1.85 1.86 1.86 1.87 1.88 1.88 1.89 1.89 1.9080 1.90 1.91 1.91 1.92 1.92 1.93 1.93 1.94 1.94 1.9590 1.95 1.96 1.96 1.97 1.97 1.98 1.98 1.99 1.99 2.00
100 2.00 2.00 2.01 2.01 2.02 2.02 2.03 2.03 2.03 2.04110 2.04 2.05 2.05 2.05 2.06 2.06 2.06 2.07 2.07 2.08120 2.08 2.08 2.09 2.09 2.09 2.10 2.10 2.10 2.11 2.11130 2.11 2.12 2.12 2.12 2.13 2.13 2.13 2.14 2.14 2.14140 2.15 2.15 2.15 2.16 2.16 2.16 2.16 2.17 2.17 2.17150 2.18 2.18 2.18 2.18 2.19 2.19 2.19 2.20 2.20 2.20160 2.20 2.21 2.21 2.21 2.21 2.22 2.22 2.23 2.23 2.23170 2.23 2.23 2.23 2.24 2.24 2.24 2.24 2.25 2.25 2.25180 2.26 2.26 2.26 2.26 2.26 2.27 2.27 2.27 2.27 2.28190 2.28 2.28 2.28 2.29 2.29 2.29 2.29 2.29 2.30 2.30200 2.30 2.30 2.30 2.31 2.31 2.31 2.31 2.32 2.32 2.32
TensHundreds 0 10 20 30 40 50 60 70 80 90
200 2.32 2.34 2.36 2.38 2.40 2.42 2.43 2.45 2.46300 2.48 2.49 2.51 2.52 2.53 2.54 2.56 2.57 2.58 2.59400 2.60 2.61 2.62 2.63 2.64 2.65 2.66 2.67 2.68 2.69500 2.70 2.71 2.72 2.72 2.73 2.74 2.75 2.76 2.76 2.77600 2.78 2.79 2.79 2.80 2.81 2.81 2.82 2.83 2.83 2.84700 2.85 2.85 2.86 2.86 2.87 2.88 2.88 2.89 2.89 2.90800 2.90 2.91 2.91 2.92 2.92 2.93 2.93 2.94 2.94 2.95900 2.95 2.96 2.96 2.97 2.97 2.98 2.98 2.99 2.99 3.00
1. pHs = (9.30 + A + B) – (C + D)(Note. Values of A, B, C, & D are obtained from tables A, B, C, & D)
2. Saturation Index = pH – pHsIf index is 0, water is in chemical balance.If index is plus quantity, scale forming tendencies are indicated.If index is a minus quantity, corrosive tendencies are indicated.
Example: To find the saturation index at 124°F of water which has thefollowing characteristics: Total solids – 400 ppm; calcium hardness as CaCO3-240 ppm; alkalinity, and as CaCO3-196 ppm; and pH of 7.2 Then:
Total solids . . . . . . . . . . . . . . . . . . 400 ppm =0.16 (from table A)Temperature . . . . . . . . . . . . . . . . . 124°F =1.53 (from table B)Calcium hardness as CaCO3 . . . . . 240 ppm = 1.98 (from lower table C )Alkalinity as CaCO3 . . . . . . . . . . . . 196 ppm = 2.29 (from upper table D)
Substituting: pHs = (9.30 + 0.16 + 1.53 ) – (1.98 + 2.29) = 6.72 (or 6.7)
Saturation Index = 7.2 – 6.7 = +0.5
238
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REFERENCE TABLES
Calcium Carbonate EquivalentsFormula, Atomic, Molecular and Equivalent Weights and Conversion Factors to CaCO3 ofSubstances Frequently Appearing in the Chemistry of Water Treatment
Aluminum Al 27.0 9.0 5.56 0.18Aluminum Chloride AlCl3 133.2 44.4 1.13 0.89Aluminum Chloride AlCl3 6H2O 241.5 80.5 0.62 1.61Aluminum Sulfate Al2(SO4)3;18H2O 666.4 111.1 0.45 2.22Aluminum Sulfate Al2(SO4)3 (anhydrous) 342.1 57.0 0.88 1.14Aluminum Hydrate Al(OH)3 78.0 26.0 1.92 0.52
Alumina Al2O3 101.9 17.0 2.94 0.34Sodium Aluminate Na2Al2O4 163.9 27.3 1.83 0.55
Ammonium Alum Al2(SO4)3 (NH4)
2SO4 24H2O 906.6 151.1 0.33 3.02
Potassium Alum Al2(SO4)3K2SO2 24H2O 948.8 156.1 0.82 3.12Ammonia NH3 17.0 17.0 2.94 0.34Ammonium (Ion) NH4 18.0 18.0 2.78 0.36Ammonium Chloride NH4Cl 53.5 53.5 0.94 1.07Ammonium Hydroxide NH4OH 35.1 35.1 1.43 0.70Ammonium Sulfate (NH4) 2SO4 132.2 66.1 0.76 1.32
Barium Ba 137.4 68.7 0.73 1.37Barium Carbonate BaCO3 197.4 98.7 0.51 1.97Barium Chloride BaCl2 2H2O 244.3 122.2 0.41 2.44Barium Hydroxide Ba(OH)2 171.4 85.7 0.59 1.71Barium Oxide BaO 153.4 76.7 0.65 1.53Barium Sulfate BaSO4 233.4 116.7 0.43 2.33
Calcium Ca 40.1 20.0 2.50 0.40Calcium Bicarbonate Ca(HCO3)2 162.1 81.1 0.62 1.62Calcium Carbonate CaCO3 100.08 50.1 1.00 1.00Calcium Chloride CaCl2 111.0 55.5 0.90 1.11Calcium Hydrate Ca(OH)2 74.1 37.1 1.35 0.74Calcium Hypochlorite Ca(ClO)2 143.1 35.8 0.70 1.43Calcium Oxide CaO 56.1 28.0 1.79 0.56Calcium Sulfate CaSO4 (anhydrous) 136.1 68.1 0.74 1.36Calcium Sulfate CaSO4 2H2O (gypsum) 172.2 86.1 0.58 1.72Calcium Nitrate Ca(NO3)2 164.1 82.1 0.61 1.64Calcium Phosphate Ca3(PO4)2 310.3 51.7 0.97 1.03
Carbon C 12.0 3.0 16.67 0.06
Chlorine (Ion) Cl 35.5 35.5 1.41 0.71
Copper (Cupric) Cu 63.6 31.8 1.57 0.64Copper Sulfate (Cupric) CuSO4 160.0 80.0 0.63 1.60Copper Sulfate (Cupric) CuSO4 5H2O 250.0 125.0 0.40 2.50
Multiplying FactorConsidering Molecular
Wt. of CaCO3 as 100
Substance Formula Atomic or Equivalent Substance CaCO3Molecular Weight to CaCO3 equivalent
Weight equivalent to substance
Multiplying FactorConsidering Molecular
Wt. of CaCO3 as 100
Substance Formula Atomic or Equivalent Substance CaCO3Molecular Weight to CaCO3 equivalent
Weight equivalent tosubstance
Iron (Ferrous) Fe’’ 55.8 27.9 1.79 0.56Iron (Ferric) Fe’’’ 55.8 18.6 2.69 0.37Ferrous Carbonate FeCO3 115.8 57.9 0.86 1.16Ferrous Hydroxide Fe (OH)2 89.9 44.9 1.11 0.90Ferrous Oxide FeO 71.8 35.9 1.39 0.72Ferrous Sulfate FeSO4 (anhydrous) 151.9 76.0 0.66 1.52Ferrous Sulfate FeSO4 7H2O 278.0 139.0 0.36 2.78Ferrous Sulfate FeSO4 (anhydrous) 151.9 151.9 oxidation
Ferric Chloride FeCl3 162.3 54.1 0.93 1.08Ferric Chloride FeCl3 6H2O 270.3 90.1 0.56 1.80Ferric Hydroxide Fe (OH)3 106.8 35.6 1.41 0.71Ferric Oxide Fe2O3 159.6 26.6 1.88 0.53Ferric Sulfate (Ferrisul) Fe2 (SO4)3 399.9 66.7 0.75 1.33Ferrous or Ferric Fe or Fe 55.8 55.8 oxidation
Fluorine F 19.0 19.0 2.66 0.38
Hydrogen (Ion) H 1.01 1.01 50.0 0.02
Iodine I 127.0 127.0 0.40 2.54
Lead Pb 207.0 103.5 0.48 2.08
Magnesium Mg 24.3 12.2 4.12 0.24Magnesium Oxide MgO 40.3 20.2 2.48 0.40Magnesium Bicarbonate Mg (HCO3)2 146.3 73.2 0.68 1.46Magnesium Carbonate MgCO3 84.3 42.2 1.19 0.84Magnesium Chloride MgCl2 95.3 47.7 1.05 0.95Magnesium Chloride
(Hexahydrate) MgCl2 6H2O 203.2 101.6 0.49 2.03 Magnesium Hydrate Mg(OH)2 58.3 29.2 1.71 0.58Magnesium Nitrate Mg(NO3)2 148.3 74.2 0.67 1.48Magnesium Phosphate Mg3(PO4)2 262.9 43.8 1.14 0.88Magnesium Sulfate MgSO4 120.4 60.2 0.83 1.20Magnesium Sulfate
(Epsom Salt) MgSO4 7H2O 246.4 123.2 0.406 2.46Manganese
(Manganous) Mn’’ 54.9 27.5 1.82 0.55Manganese (Manganic) Mn’’’ 54.9 18.3 2.73 0.37Manganese Chloride MnCl2 125.8 62.9 0.80 1.26Manganese Dioxide MnO2 86.9 21.7 2.30 0.43Manganese Hydrate Mn(OH)2 89.0 44.4 1.13 0.89Manganic Oxide Mn2O3 157.8 26.3 1.90 0.53Manganous Oxide MnO 70.9 35.5 1.41 0.71
239
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
REFERENCE TABLES
Multiplying FactorConsidering Molecular
Wt. of CaCO3 as 100
Substance Formula Atomic or Equivalent Substance CaCO3Molecular Weight to CaCO3 equivalent
Weight equivalent to substance
Multiplying FactorConsidering Molecular
Wt. of CaCO3 as 100
Substance Formula Atomic or Equivalent Substance CaCO3Molecular Weight to CaCO3 equivalent
Weight equivalent tosubstance
Nitrate (Ion) NO3 62.0 62.0 0.81 1.24
Nitric Acid HNO3 63.0 63.0 0.79 1.26
Nitrogen (Valence 3) N’’’ 14.0 4.7 10.8 0.093
Nitrogen (Valence 5) N’’’’’ 14.0 2.8 17.9 0.056
Oxygen O 16.0 8.0 6.25 0.16
Phosphorus (Valence 3) P’’’ 31.0 10.3 4.76 0.21
Phosphorus (Valence 5) P’’’’’ 31.0 6.2 8.33 0.12
Potassium K 39.1 39.1 1.28 0.78
Potassium Carbonate K2CO3 138.0 69.1 0.72 1.38
Potassium Chloride KCl 74.6 74.6 0.67 1.49
Potassium Hydroxide KOH 56.1 56.1 0.88 1.12
Silver Chloride AgCl 143.3 143.3 0.35 2.87
Silver Nitrate AgNO3 169.9 169.9 0.29 3.40
Silica SiO2 60.1 60.1 0.83 1.2
Silicon (Valence 4) Si’’’’ 28.1 7.03 7.14 0.14
Sodium Na 23.0 23.0 2.18 0.46
Sodium Bicarbonate NaHCO3 84.0 84.0 0.60 1.68
Sodium Bisulfate NaHSO4 120.1 120.1 0.42 2.40
Sodium Bisulfite NaHSO3 104.1 104.1 0.48 2.08
Sodium Carbonate Na2CO3 106.0 53.0 0.94 1.06
Sodium Chloride NaCl 58.5 58.5 0.85 1.17
Sodium Hypochlorite NaClO 74.5 37.3 0 .67 1.49
Sodium Hydroxide NaOH 40.0 40.0 1.25 0.80
Sodium Nitrate NaNO3 85.0 85.0 0.59 1.70
Sodium Nitrite NaNO2 69.0 69.0 0.73 1.38
Sodium Oxide Na2O 62.0 31.0 1.61 0.62
Tri-sodium Phosphate Na3PO4 12H2O
(18.7% P2O5) 380.2 126.7 0.40 2.53
Tri-sodium Phosphate
(anhydrous) Na3PO4 (43.2% P2O5) 164.0 54.7 0.91 1.09
Di-sodium Phosphate Na2HPO4 12H2O
(19.8% P2O5) 358.2 119.4 0.42 2.39
Di-sodium Phosphate
(anhydrous) Na2HPO4 (50% P2O5) 142.0 47.3 1.06 0.95
Monosodium Phosphate NaH2PO4 H2O
(51.4% P2O5) 138.1 46.0 1.09 0.92
Mono-sod. (anhydrous) NaH2PO4 (59.1% P2O5) 120.0 40.0 1.25 0.80
Meta-Phosphate
(Hagan) NaPO3 (69% P2O5) 102.0 34.0 1.47 0.68
Sodium Sulfate Na2SO4 142.1 71.0 0.70 1.42
Sodium Thiosulfate Na2S2O3 158.1 158.1 0.63 1.59
Sodium Tetrathionate Na2S4O6 270.2 135.1 0.37 2.71
Sodium Sulfite Na2SO3 126.1 63.0 0.79 1.26
Strontium Sr 87.6 43.8 1.14 0.88
Sulfur (Valence2) S’’ 32.1 16.0 3.13 0.32
Sulfur (Valence4) S’’’’ 32.1 8.02 6.25 0.16
Sulfur (Valence 6) S’’’’’’ 32.1 5.34 9.10 0.11
Sulfur Dioxide SO2 64.1 32.0 1.56 0.64
Tin (Valence 2) Sn’’ 119.0 59.5 0.84 1.19
Water H2O 18.0 9.00 5.56 0.18
Zinc (Valence 2) Zn’’ 65.4 32.7 1.54 0.65
ACID RADICALSBicarbonate HCO3 61.0 61.0 0.82 1.22
Carbonate CO3 60.0 30.0 1.67 .60
Carbon Dioxide CO2 44.0 44.0 1.14 .88
Chloride Cl 35.5 35.5 1.41 .71
Iodide l 126.9 126.9 0.40 2.54
Nitrate NO3 62.0 62.0 0.81 1.24
Hydroxyl OH 17.0 17.0 2.94 0.34
Phosphate PO4 95.0 31.7 1.58 0.63
Phosphorous Oxide P2O5 142.0 23.7 2.11 0.47
Sulfide (Valence 2) S’’ 32.1 16.0 3.11 0.32
Sulfate SO4 96.1 48.0 1.04 0.96
Sulfur Trioxide SO3 80.1 40.0 1.25 0.80
ACIDSHydrogen H 1.0 1.0 50.00 0.02
Acetic Acid HC2H3O2 60.1 60.1 0.83 1.20
Carbonic Acid H2CO3 62.0 31.0 1.61 0.62
Hydrochloric Acid HCl 36.5 36.5 1.37 0.73
Phosphoric Acid H3PO4 98.0 32.7 1.53 0.65
Sulfurous Acid H2SO3 82.1 41.1 1.22 0.82
Sulfuric Acid H2SO4 98.1 49.0 1.02 0.98
Hydrogen Sulfide H2S – – – –
Manganous Acid H2MnO3 104.9 52.5 0.95 1.05
240
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REFERENCE TABLES
Equivalents
EQUIVALENTS OF PRESSURE AND HEAD
(1) To Obtain pound/in2 pound/ft2 Atmospheres kg/cm2 kg/m2 inch water foot water inch mercury mm mercury bar** megapascal(68°F) (68°F) (32°F)* (32°F)* (MPa)**
(2) Multiply (3) By
pound/in2 1 144 0.068046 0.070307 703.070 27.7276 2.3106 2.03602 51.7150 0.06895 0.006895pound/ft2 0.0069445 1 0.000473 0.000488 4.8241 0.1926 0.01606 0.014139 0.35913 0.000479 0.0000479Atmospheres 14.696 2116.22 1 1.0332 10332.27 407.484 33.9570 299.921 760 1.01325 0.101325kg/cm2 14.2233 2048.155 0.96784 1 10000 394.38 32.8650 28.959 735.559 0.98067 0.098067kg/m6 0.001422 0.204768 0.0000968 0.0001 1 0.3944 0.003287 0.002896 0.073556 0.000098 0.0000098inch water* 0.036092 5.1972 .002454 0.00253 25.375 1 0.08333 0.073430 1.8651 0.00249 0.000249foot water* 0.432781 62.3205 0.029449 0.03043 304.275 12 1 0.88115 22.3813 0.029839 0.0029839inch mercury** 0.491154 70.7262 0.033421 0.03453 345.316 13.6185 1.1349 1 25.40005 0.033864 0.0033864mm mercury** 0.0193368 2.78450 0.0013158 0.0013595 13.59509 0.53616 0.044680 0.03937 1 0.001333 0.0001333bar** 14.5038 2088.55 0.98692 1.01972 10197.2 402.156 33.5130 29.5300 750.062 1 0.10MPa** 145.038 20885.5 9.8692 10.1972 101972.0 4021.56 335.130 295.300 7500.62 10.0 1
*Water at 68°F (20°C) Mercury at 32°F (0°C) **MPa (megapascal) = 10 bar = 1,000,000 N/m2 (newton/meter2)
EQUIVALENTS OF LIQUID MEASURES AND WEIGHTS
(1) To Obtain Gallon Imperial Gallon Pint Pound Water* Cubic Foot Cubic Inch Liter Cubic Meter
(2) Multiply (3) By
Gallon 1 0.833 8 8.337 0.13368 231 3.78533 0.003785
Imperial Gallon 1.2009 1 9.60752 10 0.16054 277.42 4.54596 0.004546
Pint 0.125 0.1041 1 1.042 0.01671 28.875 0.473166 0.000473
Pound Water* 0.11995 0.1 0.9596 1 0.016035 27.708 0.45405 0.000454
Cubic Foot 7.48052 6.22888 59.8442 62.365 1 1728 2831702 0.028317
Cubic Inch 0.004329 0.00361 0.034632 0.03609 0.0005787 1 0.016387 0.0000164
Liter 0.2641779 0.2199756 2.113423 2.202 0.0353154 61.02509 1 0.001000
Cubic Meter 264.170 219.969 2113.34 2202 35.31446 61023.38 999.972 1
*Water at 60°F (15.6°C) 1 Barrel = 42 gallons (petroleum measure)
s
s s
s
s s
EQUIVALENTS OF FLOW RATE
(1) To Obtain gpm gpd lpm m3/hr ft3/min pound/min
(2) Multiply (3) By
gpm. . . . . . . . . . . . . . . . . . . 1. . . . . . . . 1440. . . . . . . . 3.785. . . . . . . . 0.2271. . . . . . . . . 0.1337. . . . . . . . . 8.337gpd . . . . . . . . . . . . . . . . . . . 0.000694. . . . . . . . 1. . . . . . . . 0.00263. . . . . . . . 0.000158. . . . . . . . . 9.284 x 10-5. . . . . . . . . 0.00579lpm . . . . . . . . . . . . . . . . . . . 0.2642. . . . . . . . 380. . . . . . . . 1. . . . . . . . 0.06. . . . . . . . . 0.0353. . . . . . . . . 2.202m3/hr . . . . . . . . . . . . . . . . . . 4.403. . . . . . . . 6370. . . . . . . . 16.67. . . . . . . . 1. . . . . . . . . 0.588. . . . . . . . . 36.71ft3/min . . . . . . . . . . . . . . . . . 7.48. . . . . . . . 10771.2. . . . . . . . 28.3. . . . . . . . 1.7. . . . . . . . . 1. . . . . . . . . 3750pound/min . . . . . . . . . . . . . . 0.1199. . . . . . . . 172.72. . . . . . . . 0.454. . . . . . . . 0.2724. . . . . . . . . 0.00267. . . . . . . . . 1
s
s s
241
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
REFERENCE TABLES
Temperature Conversion, Tank Areas and Volume
TANK AREAS AND VOLUMES*
Area = sq. ft. or cu. ft. per ft. of depth U.S. Gallons per ft of depthNominal Diameter Unlined Lined Unlined Lined
12” . . . . . . . . . . . . . . . . . . 0.785 . . . . . . . . . . . . 0.765 . . . . . . . . . . . . 5.87. . . . . . . . . . . 5.7314” . . . . . . . . . . . . . . . . . . 1.069 . . . . . . . . . . . . 1.049 . . . . . . . . . . . . 8.0. . . . . . . . . . . . 7.8616” . . . . . . . . . . . . . . . . . . 1.396 . . . . . . . . . . . . 1.372 . . . . . . . . . . . . 10.44. . . . . . . . . . . 10.2718” . . . . . . . . . . . . . . . . . . 1.767 . . . . . . . . . . . . 1.748 . . . . . . . . . . . . 13.22. . . . . . . . . . . 13.0920” . . . . . . . . . . . . . . . . . . 2.182 . . . . . . . . . . . . 2.157 . . . . . . . . . . . . 16.32. . . . . . . . . . . 16.1224” . . . . . . . . . . . . . . . . . . 3.142 . . . . . . . . . . . . 3.104 . . . . . . . . . . . . 23.50. . . . . . . . . . . 23.2030” . . . . . . . . . . . . . . . . . . 4.784 . . . . . . . . . . . . 4.703 . . . . . . . . . . . . 35.8. . . . . . . . . . . . 35.236” . . . . . . . . . . . . . . . . . . 6.918 . . . . . . . . . . . . 6.821 . . . . . . . . . . . . 51.8. . . . . . . . . . . . 51.042” . . . . . . . . . . . . . . . . . . 9.444 . . . . . . . . . . . . 9.33 . . . . . . . . . . . . . 70.6. . . . . . . . . . . . 69.848” . . . . . . . . . . . . . . . . . . 12.36 . . . . . . . . . . . . . 12.24 . . . . . . . . . . . . . 92.5. . . . . . . . . . . . 91.654” . . . . . . . . . . . . . . . . . . 15.67 . . . . . . . . . . . . . 15.53 . . . . . . . . . . . . . 117.0. . . . . . . . . . . . 116.060” . . . . . . . . . . . . . . . . . . 19.37 . . . . . . . . . . . . . 19.22 . . . . . . . . . . . . . 145.0. . . . . . . . . . . . 144.066” . . . . . . . . . . . . . . . . . . 23.47 . . . . . . . . . . . . . 23.30 . . . . . . . . . . . . . 176.0. . . . . . . . . . . . 174.072” . . . . . . . . . . . . . . . . . . 27.96 . . . . . . . . . . . . . 27.77 . . . . . . . . . . . . . 209.0. . . . . . . . . . . . 208.078” . . . . . . . . . . . . . . . . . . 32.84 . . . . . . . . . . . . . 32.63 . . . . . . . . . . . . . 246.0. . . . . . . . . . . . 244.084” . . . . . . . . . . . . . . . . . . 38.0 . . . . . . . . . . . . . . 37.77 . . . . . . . . . . . . . 284.0. . . . . . . . . . . . 283.090” . . . . . . . . . . . . . . . . . . 43.67 . . . . . . . . . . . . . 43.42 . . . . . . . . . . . . . 327.0. . . . . . . . . . . . 325.096” . . . . . . . . . . . . . . . . . . 49.71 . . . . . . . . . . . . . 49.45 . . . . . . . . . . . . . 372.0. . . . . . . . . . . . 370.0102” . . . . . . . . . . . . . . . . . 56.15 . . . . . . . . . . . . . 55.8 . . . . . . . . . . . . . . 420.0. . . . . . . . . . . . 418.0108” . . . . . . . . . . . . . . . . . 62.99 . . . . . . . . . . . . . 62.70 . . . . . . . . . . . . . 471.0. . . . . . . . . . . . 469.0114” . . . . . . . . . . . . . . . . . 70.07 . . . . . . . . . . . . . 69.91 . . . . . . . . . . . . . 524.0. . . . . . . . . . . . 523.0120” . . . . . . . . . . . . . . . . . 77.68 . . . . . . . . . . . . . 77.51 . . . . . . . . . . . . . 581.0. . . . . . . . . . . . 580.0126” . . . . . . . . . . . . . . . . . 85.68 . . . . . . . . . . . . . 85.51 . . . . . . . . . . . . . 641.0. . . . . . . . . . . . 640.0132” . . . . . . . . . . . . . . . . . 94.07 . . . . . . . . . . . . . 93.89 . . . . . . . . . . . . . 704.0. . . . . . . . . . . . 702.0
*These figures are actual values that have been corrected for shell thickness and true inside diameter measurements. Lining is 3/23" up to 60"; 1/8" above 60".
FAHRENHEIT/CENTIGRADE TEMPERATURE CONVERSION CHART
212° 32°
320° 290° 260° 230° 200° 170° 140° 110° 80° 50° 20° -10° -40°
160° 140° 120° 100° 80° 60° 40° 20° 0° -20° -40°
°C
°F
242
Siemens Water Technologies24-hr Customer Service: 800.466.7873
Section Table of ContentsBACK
REFERENCE TABLES
Relative Size of Particles
Carbon Black Beach SandJewelers Rouge
Pollens
A KEY TO THE RELATIVE SIZES OF PARTICLES
Clouds/Fog Drizzle
Virus Bacteria Mist
Electron MicroscopyColloidal
Suspended Matter
Lung-Damaging DustPleuro-Pneumonia-Like
Organisms
Ultrafiltration MacrofiltrationMicrofiltration
0.0010.001
0.002
0.004
0.0060.0080.01
0.02
0.04
0.040.080.1
0.2
0.4
0.60.881.0
2 4 6 8 10 20 40 60 80 100
200
400
6008001000
Microm
etersµm
Tobacco Smoke
Polio Virus
Pseudomonas Dim
inuta Organism
Serratia Marcescens O
rganism
Pseudomonas Cepacia O
rganism
Yeasts and FungiRed Blood Cell
Aluminum
FoilRagweed Pollen
Smallest Visible Particle
Flour
Human Hair Diam
eter
Razer Blade Thickness
Sewing NeedleDiam
eter
243REFERENCE TABLES
Velocity of Liquids in Pipes
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
ExampleGiven: Maximum flow rate of a liquid will be 300 gpm with maximum velocity limited to 12 feet persecond through Schedule 40 pipe.
Find: The smallest pipe size and the velocity through thepipe.
Solution:
VELOCITY OF LIQUIDS IN PIPE
The mean velocity of any flowing liquid can be calculated from the following formula, or from the nomographto the right. The nomograph is a graphical solution of theformula.
n = 183.3 q/d2 = 0.408 Q/d = 0.0509 W/d2ρ
(where d2 is the square of the inside diameter of commercialwrought steel pipe)
The pressure drop per 100 feet and the velocity in schedule 40 pipe, for water at 60°F, have been calculatedfor commonly used flow rates for pipe sizes of 1/8 to 24 inch.
Connect Read1. Q = 300 v = 12 d = 2.752. 3 " Schedule 40 pipe suitable3. Q = 300 3" Sched 40 ν = 10
W
ν
dρ
Reasonable Velocities for the Flow of Water through PipeService Condition Reasonable VelocityBoiler Feed . . . . . . . . . . . . . . . . . . . . . . . . . 8 to 15 ft per secondPump suction and drain lines . . . . . . . . . . . . 4 to 7 ft per secondGeneral Service . . . . . . . . . . . . . . . . . . . . . 4 to 10 ft per secondCity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to 7 ft per second
Information contained here was obtained from “Flow of Fluids through Valves, Fittings and Pipe”, Copyright 1969 Crane Co.
Main Table of Contents
Siemens Water Technologies24-hr Customer Service: 800.466.7873
This page intentionally left blank
BACK
BACK Main Table of Contents
Index and Glossary
GLOSSARY OF KEY TERMS .................................................................246
TRADEMARK STATEMENT ...................................................................253
T A B L E O F
C O N T E N T S
245
246
Siemens Water Technologies24-hr Customer Service: 800.466.7873
BACK
AABSOLUTE: A degree of filtration, usually referring to 99.9999%removal of particulates greater than a stated size.
ACID: A substance that releases hydrogen ions when dissolved inwater. Most acids will dissolve common metals, and will reactwith a base to form a neutral salt and water. A chemical used toregenerate cation ion exchange resin.
ACIDITY: An expression of the concentration of hydrogen ionspresent in a solution.
ACTIVATED CARBON: Carbon activated by high temperaturesteam or carbon dioxide to form a material of high adsorptivecapacity. A porous material available in powdered or granularform, activated carbon is used primarily for the removal ofchlorine and chloramines or dissolved organic matter.
ALKALINITY: In natural water, alkalinity results from the presenceof CO2, bicarbonate, carbonate, and hydroxide components. Thealkalinity test measures the quantity of alkaline materials inwater, whereas, the pH test indicates whether a water sample isacidic or basic.
ALUM: Aluminum sulfate [Al(SO4)3 • 18 H2O], widely used forflocculation of contaminants in municipal water treatment,typically for the removal of color and turbidity.
ANION: A negatively charged ion.
ANTHRACITE: A granular, hard coal, used sometimes as a sandfilter media. In an activated form, anthracite is commonly usedfor organic and chlorine removal (activated carbon) from water.
ANTI-TELESCOPING DEVICE (ATD): A plastic cover that looks like awheel with spokes, and is attached to the ends of a spiral woundRO cartridge to prevent distortion of the cartridge leaves causedby high flows.
AVERAGE TRANSMEMBRANE PRESSURE: Average transmembranepressure is the actual net driving force of water within a UF orRO module. It is determined as follows:
200 psi = RO feed pressure
+190 psi = RO reject pressure
390 ÷2 = 195 195 = average transmembrane pressure (assuming the permeatepressure is 0)
BBACKFLOW: Flow of water in a pipe or line in a direction oppositeto the normal flow. Often associated with the flow of possiblycontaminated water into a potable water system.
BACKWASH: The process in which beds of filter or ion exchangemedia are subjected to flow in the opposite direction from theservice flow to loosen the bed and flush out suspended matter.
BACTERIA: Unicellular microorganisms that typically reproduceby cell division. May or may not be harmful to humans.
BASE: A substance that releases hydroxyl ions when dissolved inwater. Bases react with acids to form a neutral salt and water.
BED DEPTH: The depth of the filter medium or ion exchangeresin in a vessel.
BED EXPANSION: The effect produced during backwashing: theresin particles become separated and rise in the column. Thisexpansion of the bed, caused by the increase in the spacebetween the resin particles, may be controlled by regulatingbackwash flow.
BOD (BIOCHEMICAL OXYGEN DEMAND): The amount of oxygenutilized by natural agencies in stabilizing organic matter atspecified test conditions.
BRACKISH WATER: Water containing dissolved solids in the rangeof 1,000 to 10,000 mg/L.
BRINE: A solution of sodium chloride (salt) used for regeneratingwater softeners. A mixed sodium, calcium and magnesiumchloride solution is the resulting waste solution fromregeneration.
BRINE SEAL: A rubber lip on the outside of a spiral wound ROcartridge that prevents feed bypass between the cartridge andthe inside pressure vessel wall.
BRINE STREAM: The reject stream from an RO cartridge. Portionof the feed stream that does not pass through the membrane.
BUBBLE POINT TEST: Used to test the integrity of 0.22 and 0.45micron microporous filters.
BUFFER: A chemical that causes a solution to resist changes inpH, or to shift the pH to a specific value.
CCALCIUM CARBONATE EQUIVALENT: A common basis forexpressing the concentration of hardness and other salts inchemically equivalent terms to simplify certain calculations.Signifies that the concentration of a dissolved mineral ischemically equivalent to the stated concentration of calciumcarbonate.
CAPACITY: The absorption ability possessed per unit of resinvolume or per unit of weight (i.e., the potential for exchange).For water softeners, the capacity is expressed in grains of
GLOSSARY
The following is a glossary of frequently used water treatment terms.
Section Table of Contents
247
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
GLOSSARY
hardness removal between regenerations, and is related to thepounds of salt used in regeneration.
CAPACITY CURVE: A graph of capacity vs. regenerant levels for anion exchange unit or system.
CATION: A positively charged ion.
CAUSTIC: Any substance that releases hydroxide ions whendissolved in water. A chemical used to regenerate anion ionexchange resin.
CAVITATION: Caused by pump starvation, cavitation is a cracklingnoise caused by bubbles imploding on the tip of impellers insidethe pump.
CHANNELING: The flow of water or other solution in a limitednumber of passages in a filter or ion exchange bed, instead ofdistributed flow through all the passages in the bed. May becaused by fouling of the bed and plugging of many passages,poor distributor design, flow rates that are too low, or faultyoperational procedures.
CHEMICAL FEEDER: A mechanical device designed to introducechemicals into a water system in proportion to water flow.
CHEVRON SEAL: A rubber lip on the outside of a spiral wound ROcartridge that prevents feed bypass between the cartridge andthe inside pressure vessel wall.
CHLORAMINES: Compounds formed when chlorine and ammoniaare mixed in water. Used to kill bacteria in water, chloramines canbe inadvertently formed in chlorinated water supplies that containnitrogenous impurities. If present in water used for dialysatepreparation, chloramines can cause illness (particularly anemia) indialyzing patients. Can be removed by activated carbon.Chloramine level can be determined by subtracting the freechlorine level from the total chlorine level.
CHLORINATION: The process of water treatment whereby a chlorinegas or liquid solution is injected into a water supply to controlmicroorganisms. The feed, demand and residual chlorine areexpressed as ppm.
CHLORINE DEMAND: A measure of the amount of chlorine that willbe consumed by organic matter and other oxidizable substancesin a water before a chlorine residual will be found. The differencebetween the total chlorine fed and the chlorine residual.
CHLORINE, FREE AVAILABLE: The hypochlorite ions (OCI -),hypochlorous acid (HOCl) or the combination thereof present inwater.
CLARIFIER: A tank in which precipitate settles.
COAGULANT: A material, such as alum, which will form agelatinous precipitate in water, and cause the agglomeration offinely divided particles into larger particles which can beremoved by settling and/or filtration.
COD (CHEMICAL OXYGEN DEMAND): The amount of oxygenrequired under specified test conditions for the oxidation ofwater borned organic and inorganic matter.
COLIFORM BACTERIA: A group of organisms primarily found inhuman and animal intestines and wastes, and thus widely usedas indicator organisms to show the presence of such wastes inwater, and the possible presence of disease-producing bacteria.
COLLOID: A substance of very fine particle size, typically between0.1 and 0.001 microns in diameter suspended in liquid ordispersed in gas. A system of at least two phases, including acontinuous liquid plus solid, liquid or gaseous particles so smallthat they remain in dispersion for a practicable time.
COLLOIDAL DENSITY INDEX: A test used to verify the performanceof point-of-use ultrafiltration systems. The test, which is verysimilar to silt density index (SDI), is used to measure colloidalconcentration upstream and downstream of the system. It isassumed that the feedwater to the system will be of very highquality, rendering the SDI test invalid.
COLONY-FORMING UNITS (CFU): Unit used in the measure of totalbacteria count.
COLOR: Dissolved or suspended matter causing discoloration ofthe water. Expressed as alpha units.
COMPACTION: The tightening of a membrane structure due tocompressive stress of operating pressure.
CONCENTRATION POLARIZATION: The phenomenon that occurswhen material retained by the membrane builds up on themembrane surface and forms a boundary layer immediatelyadjacent to the membrane surface. Over time, this layer causes adecrease in flux.
CONDUCTIVITY: The electrical measurement of the water’s abilityto pass electric current. It is dependent on temperature and totalconcentration of ionized substances in solution. The lower thelevel of ionized substances, the lower the conductivity.Conductivity is inverse of resistivity and is measured inmicrosiemens/cm.
CONTINUOUS ELECTRODEIONIZATION (CEDI): A process that uses ionexchange membranes, ion exchange resins and electricity toproduce consistent high-purity water without the need forchemical regeneration. CEDI removes dissolved, ionizable materialssuch as dissolved silica, carbon dioxide and some organics.
CONVERSION: The percentage of feed water that ends up as theproduct, or permeate. Also known as recovery.
CROSSFLOW MEMBRANE FILTRATION: A separation of thecomponents of a fluid by semipermeable membranes throughthe application of pressure and tangential flow to the membranesurface. Includes the processes of reverse osmosis, ultrafiltration,nanofiltration, and microfiltration.
248
Siemens Water Technologies24-hr Customer Service: 800.466.7873
BACK
DDECARBONATOR: A device to remove carbon dioxide from water.
DECAT WATER: Water that has an absence of cations. Usuallyproduced by a cation resin regenerated with acid.
DEGASIFICATION: The process of removing dissolved gasses inwater.
DEIONIZATION: The removal of all ionized minerals and salts (bothorganic and inorganic) from a solution by ion exchange.Positively charges ions are removed by a cation exchange resinin exchange for a chemically equivalent amount of hydrogenions. Negatively charged ions are removed by anion exchangeresin for a chemically equivalent amount of hydroxide ions. Thehydrogen and hydroxide ions introduced in this process unite toform water molecules. The term is often used interchangeablywith demineralization.
DEMINERALIZATION: The process of removing minerals fromwater, usually through deionization, reverse osmosis, ordistillation.
DEPTH FILTER: A filter of compacted sand, or diatomaceousearth; sintered metal or glass; spool wound cotton fiber; orcompressed, matted fibers. Particles are retained in and on anyor all of the above by random adsorption or entrapment withinthe matrix of the filters. Efficiency of depth filters are rated innominal terms.
DIALYSATE: The solution used in an artificial kidney machine toremove excess fluids and metabolic end products from the blood.
DIALYSIS: The separation of components of a solution bydiffusion through a semi-permeable membrane which is capableof passing certain ions or molecules while rejecting others.
DIATOMACEOUS EARTH: A powder-like filter media made fromcrushed diatoms capable of submicron particle removal.
DIFFERENTIAL PRESSURE: The difference in pressure betweentwo given points in a water system. May be due to differences inelevation, or to friction losses or pressure drops due to resistanceto flow in pipes, softeners, filters or other devices.
DISINFECTION: The process of killing disease-producing bacteria.
DISSOLVED IRON: In water conditioning, iron is usuallydescribed as being dissolved or undissolved. The dissolved orferrous iron is ver y soluble in most water, and theundissolved ferric iron is almost always insoluble.
DISSOLVED SOLIDS: The residual material remaining after filteringthe suspended material from water and evaporating the solutionto a dry state.
DISTILLATION: The process in which a liquid, such as water, isconverted into its vapor state by heating, and the vapor cooledand condensed to the liquid state and collected. Used to removesolids and other impurities from water.
DISTRIBUTOR: Used within softener or DI tank to distribute theflow of water throughout the tank and to prevent resin fromescaping the vessel. Sometimes called a strainer.
EE. COLI: Escherichia coli, one of the members of the coliformgroup of bacteria associated with animal and human waste.Normally used by health departments to rule on the purity of adrinking water supply.
EFFLUENT: The water emerging from a treatment unit, system orprocess, such as the product from an ion exchange unit.
ELECTRODEIONIZATION: A process that removes ionizable speciesfrom liquids using an electrically active media and an electricalpotential to influence ion transport.
ELECTROLYTE: A chemical compound that dissociates or ionizesin water to produce a solution that will conduct an electricalcurrent; an acid, base, or salt.
ELEMENT: Usually another term for filter or cartridge.
EXHAUSTION: The state in which resin is no longer capable ofuseful ion exchange. The depletion of the exchanger’s supply ofavailable ions. The exhaustion point is determined in terms of a).a value in parts per million of ions in the effluent solution, b).the reduction in quality of the effluent water determined by aconductivity bridge which measures the electrical resistance ofthe water.
FFEED: Raw or untreated water entering a water purificationsystem or ion exchange system for further treatment or“polishing”.
FILTRATE: Also called permeate or product, filtrate is the purifiedportion of a solution that passes through a membrane.
FINES: Extremely small particles of filter media or ion exchangematerial, formed either in the manufacturing process or as aresult of breakdown. Undesirable in most systems because ofhigh pressure drop.
FLOCCULATION: The agglomeration of finely divided suspendedsolids into larger, usually gelatinous, particles. Thedevelopment of a “floc” after treatment with a coagulant bygentle stirring or mixing.
GLOSSARY
Section Table of Contents
249
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
GLOSSARY
FLUX: The rate of fluid passage through a given area ofmembrane per unit of time. Usually expressed in gallons persquare foot per day (gfd).
FORMALIN: A clear, aqueous solution of formaldehyde and asmall amount of methanol, used as a sanitant.
FORWARD AIR FLOW TEST: Also called “diffusion test” and“integrity test”, the forward air flow test is a measurement of thevolume of gas which will pass through a membrane at a givenpressure. Used to detect any flaws in the integrity of membranesor seals. In critical applications, this test should be performedprior to each process run.
FOULING: The rapid reduction in flux, caused by the build-up ofretained material on the membrane surface. The process inwhich undesirable foreign matter accumulates in a bed of filtermedia or ion exchanger, clogging pores and coating surfacesand thus preventing proper operation of the bed. Typicalsymptoms of fouling are: a decrease in rated product flow (flux),a decrease in percent salt rejection (RO membrane only), a rapidincrease of feed vs. reject differential pressure.
FOULING INDEX: Used synonymously with the terms “pluggagetest” and “silt density index”. A test used to determine theconcentration of colloids and particles in water fed to RO or UFsystems. The test results can be used to determine theeffectiveness of pretreatment systems and/or the need forpretreatment. Silt density index is also the best method topredict fouling characteristics caused by undissolvedcontaminants.
GGRAINS CAPACITY: The amount of minerals that will be removedby a specific quantity of resin.
GRAM NEGATIVE BACTERIA: A type of bacteria capable ofsurviving and multiplying in all types of waters, even thosetreated by reverse osmosis, deionization, softeners, anddistillation. Dead gram negative bacteria contain bacterialendotoxin, or pyrogens, that cause a fever when injected intothe bloodstream.
GREENSAND: A mineral (glauconite), used as a filtration medium.
HHARDNESS: The solution of calcium and magnesium as cationsindependent of the nature of anions present. Generallyexpressed in terms of calcium carbonate.
HARDNESS LEAKAGE: The presence of hardness minerals(calcium and magnesium) after water has passed through thesoftener. Hardness leakage is caused primarily by resin bedchanneling, due to improper backwashing, the existence ofalgae, or a combination of a high service flow with a highhardness content.
HIGH-PURITY WATER: Highly treated water with attention tomicrobiological, particle, organics and mineral reduction orelimination.
IINFLUENT: The water entering a treatment unit, system orprocess, such as the feed entering an ion exchange unit.
ION EXCHANGE: A process in which certain ions of a given chargemay be absorbed from solution and replaced in the solution bydifferent ions of a similar charge from the resin.
LLAL: Abbreviation for Limulus Amebocyte Lysate, a reagent usedto detect endotoxins (pyrogens) in a water supply.
LANGELIER SATURATION INDEX: A measure of the probability ofwhether water will precipitate or dissolve calcium carbonate,which forms scaling on the walls of pipes and RO membranes.The index is calculated from the total calcium, alkalinity, pH,temperature, and total dissolved solids of the water. A positiveindex indicates scaling tendencies, while a negative indexindicates that scaling will not occur.
LEAKAGE: The phenomenon in which some of the influent ionsare not removed and appear in the effluent of an ion exchangesystem. Leakage may be caused by incomplete regeneration,excessive flow rates, low temperatures, the concentration orcharacteristics of the influent ions.
LIME SCALE: Hard water scale containing a high percentage ofcalcium carbonate.
MMACRORETICULAR: A term used to describe resins that have arigid polymer porous network in which there exists a true porestructure even after drying. The pores are larger than atomicdistances and are not part of the gel structure.
MANGANESE GREENSAND: A manganese-coated greensand usedas a filter medium for removal of manganese and iron.
MEGOHM: One million ohms. Usually used as a measure of waterpurity, on resistivity in megohm-cm.
MEMBRANE: Media through which a liquid is passed. The term isusually used to define the functional filter material, and not itssupporting substrate, screens or other cartridge components.The word membrane is often used synonymously with filter orcartridge.
MESH: The number of openings in a lineal inch of wire cloth.
MHO: A measure of conductance, reciprocal of ohms.
250
Siemens Water Technologies24-hr Customer Service: 800.466.7873
BACK
MICROFILTRATION: Filtration designed to remove particles andbacterial in the approximate range of 0.05 to 10 micrometers.
MICROMHO (MICROSIEMENS): One millionth of a Mho. Unit ofmeasurement for conductivity (equivalent to the inverse of 1million ohms of resistivity). Water quality is measured by itsconductivity in micromhos per centimeter. The higher thequality the lower the micromho reading.
MICRON (MICROMETERS): A metric unit of measurementequivalent to 10-6 meters, 10-4 centimeters. System is η.
MICROPOROUS FILTRATION: Often used synonymously with theterms “absolute filtration” and occasionally “screen filtration”,microporous filters (or devices) have absolute ratings and will“absolutely” remove contaminants larger than their rated poresize, except for some types of bacteria that can “grow through”the filter.
MIXED BED ION EXCHANGE: A demineralization process where theanion and cation ion exchange resins are mixed in the samevessel.
NNANOFILTRATION (NF): A crossflow membrane separation processwhich removes particles in the 300 to 1000 molecular weightrange, selected salts and most organics.
NEGATIVE PRESSURE: A pressure below that of the surroundingatmospheric pressure at a specific point; a partial vacuum.
NEUTRALIZATION: The addition of either an acid or a base to asolution as required to produce a neutral solution. The use ofalkaline or basic materials to neutralize the acidity of somewaters is a common practice in water conditioning.
OOPERATING PRESSURE: The range of pressure, usually expressedin pounds per square inch, over which a water system isdesigned to function.
ORGANIC MATTER: Substances derived from plant or animalmatter, as opposed to inorganic matter derived from rocks andminerals. Organic matter is characterized by its carbon-hydrogenstructure.
OSMOSIS: The diffusion of a solvent through a semi-permeablemembrane from a less concentrated solution to a moreconcentrated solution.
OSMOTIC PRESSURE: The pressure required to preventspontaneous flow of water into a solution separated by a semi-permeable membrane.
OXIDATION: A chemical process in which electrons are removedfrom an atom, ion or compound. The addition of oxygen is aspecific form of oxidation. Combustion is an extremely rapid forof oxidation, while the rusting of iron is a slow form.
OXIDIZING FILTERS: Filters that remove both iron and manganesefrom the water. The units, also called iron removal filters, containa filter medium that has the ability of oxidizing and absorbingdissolved iron and manganese. The filter is regenerated withpotassium permanganate and cleaned with backwashing. Anoxidizing filter can also consist of a tank where iron is oxidizedwith air and the deposit is collected in a sand filter.
OZONE: An unstable form of oxygen (O3) that can be generatedby an electrical discharge through air or oxygen. A strongoxidizing agent, ozone can be used to disinfect water systems.
PpH: An expression of the acidity of a solution. The negativelogarithm of the hydrogen ion concentration. A pH of 1 is veryacidic; pH 7 is neutral; pH 14 is very basic.
PARTS PER MILLION: A measure of concentration. One part permillion of water is equivalent to 1 mg/liter of liquid. This is alsoequivalent to 0.0584 grains/U.S. gallon. 17.1 ppm is equal to 1grain per gallon.
PERACETIC ACID: A clear, colorless liquid with a pungent odor,composed of hydrogen peroxide and acetic acid. Can be usedto sanitize water systems and cartridges.
PERMEATE: The portion of the feed stream that passes throughthe membrane and emerges as purified water.
PERMEATOR: A name for an RO element or module. The unit thatcontains the semi-permeable membrane, and is constructed toallow the purified water to pass through the membrane, underpressure, while leaving behind the reject portion.
PLUGGAGE TEST: Used synonymously with the terms “foulingindex” and “silt density index”. A test used to determine theconcentration of colloids and particles in tap water fed to an ROor UF system. The test results can be used to determine theeffectiveness of pretreatment systems and/or the need forpretreatment. Silt density index is also the best method to predictfouling characteristics caused by undissolved contaminants.
POLISHING: Additional purification by RO, ion exchange, etc., toproduce exceptionally pure water.
POTABLE WATER: Water that is suitable for human consumption.
PRESSURE DIFFERENTIAL: The difference in pressure betweentwo points in a system caused by differences in elevationand/or pressure drop due to flow.
GLOSSARY
Section Table of Contents
251
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
Section Table of ContentsBACK
GLOSSARY
PRODUCT: The treated (filtered, deionized, etc.) water from awater purification system.
PYROGEN: A substance or agent that, when introduced into theblood stream of man or warm-blooded animals, produces fever.Endotoxins produced from gram negative bacteria fall under thisdefinition. Pyrogens can be removed by RO and UF membranes.
RRATED CAPACITY: The basis for calculating the period of time, ornumber of gallons delivered by a water softener, deionizer orfilter, between regenerations or servicing, as determined underspecific test conditions.
RAW WATER: Untreated water from wells or from surface sources.
RECOVERY: Expressed in percent, recovery is the portion of theRO feed water that is converted to product. Percent recovery iscalculated as follows: Product Flow X 100 = Percent Recovery
Feed Flow
REGENERATION: The chemical restoration of cation and anionresins by treatment with acid and caustic respectively.
REJECT: The portion of the feed stream that does not passthrough the membrane to become permeate (purified), but isretained by the membrane, and eventually passes to drain. Thiswater contains the bulk of the dissolved matter along withparticulates and microorganisms. Reject is used synonymouslywith the terms concentrate, brine, retentate and waste.
REJECT DELTA P: The pressure differential between themembrane feed pressure and reject pressure.
RESISTIVITY (OF WATER): The electrical measurement of thewater’s ability to resist the flow of electric current, and isdependent on the temperature and total concentration of theionized substances in solution. The lower the level of ionizedsubstances, the higher the resistivity. Resistivity is the inverse ofconductivity, and is measured in megohms per centimeter.
REVERSE OSMOSIS (RO): The process by which a solution underpressure (in excess of osmotic pressure) is forced through a semi-permeable membrane from a more concentrated to a lessconcentrated solution.
SSALT PASSAGE: Expressed in percent, salt passage is the ratio ofsalt concentration in the product water to salt concentration inthe RO feed water.
SALT REJECTION: Expressed in percent, salt rejection is the saltconcentration rejected by the RO membrane. Percent saltrejection is calculated as follows:
% Salt Rejection = Conductivity of Feed - Conductivity of Permeate X 100Conductivity of Feed
SAND FILTER: Packed bed of sand that can remove particles downto 25 microns. Can be regenerated by backwashing.
SANITIZE: A process performed to reduce the number of bacteria.
SCALE: The precipitate of sparingly soluble salts that forms onsurfaces in contact with water as a result of physical orchemical change.
SEMI-PERMEABLE MEMBRANE: Usually a thin, membrane that willallow the passage of some ions or materials while preventingthe passage of others.
SEPARATE BED ION EXCHANGE: A demineralization process wherethe anion and cation exchange resins are in separate vessels, asopposed to mixed bed ion exchange, where the anion andcation resins are in the same vessel.
SEPARATION: The dividing of two or more types of resin by specificgravity. Usually achieved by backwashing at a specified flow.
SILT DENSITY INDEX: A test used to determine the concentration ofcolloids and particles in water fed to an RO or UF system. The testresults can be used to determine the effectiveness of pretreatmentsystems and/or the need for pretreatment systems. Silt densityindex is also the best method to predict fouling characteristicscaused by undissolved contaminants (fouling index).
SINGLE PASS: Refers to a single-pass RO system in which aportion of the feed water to the system will pass one timethrough an RO membrane to be purified.
SOFTENER: Ion-exchange device that removes hardness fromwater by exchanging calcium and magnesium in the water forsodium ions. The softener is regenerated with sodium chloride,and the calcium and magnesium salts are rinsed to drain.
SOFT WATER: Any water that contains less than 1.0 gpg (17.1mg/L) of hardness minerals, expressed as calcium carbonate.
SPIRAL WOUND RO CARTRIDGE: A cartridge that is constructedwith a sheet of open-structured support material “sandwiched”between two sheets of RO membrane, wound spirally around aperforated, PVC core. As the untreated water (feed) flowsthrough the support material, purified water permeates thelayers of the membrane into the core, where is is extracted aspermeate. The bulk of dissolved ions and particles are rejected,and diverted to drain.
STERILIZE: To kill or destroy all microorganisms.
SURFACTANT (SURFACE-ACTIVE AGENT): The material in a soap ordetergent formulation that promotes the loosening of the soilfrom surfaces and the suspension of many soils. The actualcleaning agent in soaps and detergents.
SUSPENSION: Foreign particles carried in a liquid but notdissolved in it, like rusty iron in water.
252
Siemens Water Technologies24-hr Customer Service: 800.466.7873
BACK
SWELLING: The expansion of certain ion exchange resins whenconverted into specific ionic states.
TTANGENTIAL FLOW: Action whereby the untreated water (feed)flow is directed across the surface of the membrane. This“sweeping” action helps keep material retained by the membranefrom settling, and eventually restricting, permeate flow.
TEMPERATURE CORRECTION FACTOR: The factor by which thewater system productivity (RO or UF) would be reduced (orincreased) due to changes in water temperature. Water viscositychanges with changes in temperature, and therefore the rate atwhich it will pass through a membrane, will change accordingly.As a rule of thumb, the system productivity may be decreased byabout 2 percent per °C decrease in temperature.
THROUGHPUT: The total volume of fluid processed through thefilters before membrane fouling occurs. Throughput is measuredin liters of filtrate produced.
TOTAL CHLORINE: The total concentration of chlorine in a watersample, including combined and free chlorine.
TOTAL DISSOLVED SOLIDS (TDS): The total of all dissolved matter(both organic and inorganic) present in a water sample.
TOTAL HARDNESS: The sum of all hardness constituents in a watersample, expressed as their equivalent concentration of calciumcarbonate. Hardness is caused primarily by calcium andmagnesium, but may also include small amounts of metals suchas iron which act like calcium and magnesium in certain reactions.
TOTAL ORGANIC CARBON (TOC): One method for determining theorganic content of a water sample (from approximately 10 ppb tothousands of ppm). In this method the organic matter is oxidizedto carbon dioxide, which is then measured by one of severalsensitive electronic detectors. Other methods of determining theorganic content in a water sample include Chemical OxygenDemand (COD), Ultraviolet Spectrophotometry, GasChromatography and Mass Spectrometry.
TOTAL SOLIDS: The weight of all solids, dissolved andsuspended, organic and inorganic, per unit of water.
TRANSMEMBRANE PRESSURE: Short for transmembranedifferential pressure. The difference between the feed pressureapplied to the upstream as compared to that of the feedpressure on the downstream (permeate) side of the membrane.Transmembrane pressure is essentially the “net driving force”that determines “flux”. Transmembrane pressure is calculated asfollows:
Feed Pressure = 250 psi–Permeate Pressure = 50 psiTransmembrane Pressure= 200 psi
TURBIDITY: A term used to define the physical appearance orcloudiness of water. Expressed in NTUs, turbidity is determinedby how much undissolved material, such as clay, silt or sand ispresent in water.
TWO PASS: Refers to a two-pass RO system in which a portion ofthe feed water to the system will pass through two ROmembranes to be purified.
UULTRAFILTRATION: A filtration process using membrane filtermaterial to retain undissolved and dissolved contaminants thatare larger than the nominal molecular weight cutoff rating ofthe membrane (typically 5,000-500,000 daltons). Essentially amolecular sieve. Ultrafiltration systems use this process todramatically reduce contaminants not removed by microporousfiltration, such as large molecular weight organics, colloids,bacteria, and particles smaller than the absolute ratings of“microporous” or “absolute” filters. Ultrafiltration differs fromreverse osmosis as a process in that it typically will not removedissolved salts.
ULTRAVIOLET STERILIZATION: Using ultraviolet (UV) radiation tokill or inhibit bacteria and viruses.
UPFLOW: The operation of an ion exchange unit in whichsolutions are passed in at the bottom and out at the top of thevessel.
USP: United States Pharmacopoeia. Publishes standards forwater for injection (pharmaceutical) and purified water.
VVIRUS: An infective agent smaller than a common bacterium.Requires living cells for multiplication.
VISCOSITY: The resistance of fluids to flow, due to internal forcesand friction between molecules.
WWFI: Abbreviation for “water for injection”. Used in preparinginjectable pharmaceuticals, WFI must be pyrogen-free.
ZZEOLITE: A group of natural or synthetic hydrated aluminumsilicates with ion exchange properties.
GLOSSARY
Section Table of Contents
253
SiemensWater Technologies
Technical Support 800.875.7873 ext. 5000
BACK Main Table of Contents
TRADEMARK STATEMENT
APEX. AquaCarb, Arrowhead, AVGF, BevMAX, CDI, CDI-LX, CHEM-AD, Chemtube, Continental,Depolox, DI Gard, DI-SDI Alert, EPV, FlexTrex, FlexRO, High Resolution Redox, Ionpure, IWT,KISCO, LiquiPure, MED-RO, MEDICA, Membrane Care, Midas, MODULAB, Penfield, Permutit,PreFlex, Prepure DP, PreVUE, PolyBlend, Postpure PP, PureFit, ROGARD, Stranco, Strantrol, Total-Check, Vantage, VoCarb, Wallace & Tiernan, USF, Westates and WinCPD are trademarks ofSiemens, its subsidiaries or affiliates.
Santoprene is a trademark of Advanced Elastomer Systems, LPANSI is a trademark of the American National Standards InstituteASME is a trademark of the American Society of Mechanical EngineersASTM is a trademark of the American Society for Testing and MaterialsATCC is a trademark of the American Type Culture CollectionAWWA is a trademark of the American Water Works AssociationAquafine and Aqualogic 2000 are trademarks of Aquafine CorporationBarnstead, B-pure, E-pure, G-pure, Diamond, EASYpure NANOpure, NANOpure Infinity,
ORGANICfree, ROpure and ULTROpure are trademarks of Barnstead/Thermolyne CorporationCLSI is a trademark of the Clinical Laboratory and Standard InstituteDow, Dowex, Dowex Marathon and Monosphere are trademarks of Dow Chemical CompanyViton is a trademark of DuPont Performance Elastomers LLCTeflon is a trademark of E.I. du Pont de Nemours & CompanyCENTRA, MEDICA and PURELAB are trademarks of ELGA LabWaterFILMTEC is a trademark of FilmTec CorporationCoLD and Nexis are trademarks of Filterite CorporationE-Cell is a trademark of GE Water Technologies, Inc.Grundfos is a trademark of Grundfoss Bjerringbro Pumpefabrik A/S CorporationAnatel and Hach are trademarks of Hach CompanyHydranautics is a trademark of Hydranautics CorporationActiflo is a trademark of Kruger, Inc.Lewatit and MonoPlus are trademarks of Lanxess Deutschland GmbHLMI is a trademark of Liquid Metronics IncorporatedAFS, Alpha-Q, AFS, Milli-Q, Milli-RO, Millipore and Super-Q are trademarks of Millipore
CorporationDiaion is a trademark of Mitsubishi Chemical CorporationUltrameter is a trademark of Myron L. CompanyThio-Bag and Whirl-Pak are trademarks of NASCONEMA is a trademark of the National Electrical Manufacturers AssociationPropor is a trademark of Parker Domnick HunterClerify is a trademark of Pentair Filtration, Inc.Chem-Tech, Chem-Tech Prime Performance, IntelliScan, IntelliSense, MICROtrac, PULSAtrol and
PULSAtron are trademarks of Pulsafeeder Inc., a unit of IDEX CorporationPurolite is a trademark of The Purolite Company Allen-Bradley is a trademark of Rockwell Automation, Inc.Amberjet and Amberlite are trademarks of Rohm & HaasFluran is a trademark of Saint-Gobain Performance PlasticsIonac is a trademark of Sybron Chemicals, Inc.Terrapure is a trademark of Terracon CorporationTrisep is a trademark of TriSep CorporationcUL and UL are trademarks of Underwriters Laboratories, Inc.USP is a trademark of The United States Pharmacopeial ConventionVictaulic is a trademark of Victaulic Company
Main Table of Contents
The information provided in this catalog contains merely general descriptions orcharacteristics of performance which in actual case of use do not always apply as
described or which may change as a result of further development of the products.An obligation to provide the respective characteristics shall only exist if expressly
agreed in the terms of the contract.
©2007 Siemens Water Technologies Corp.All Rights Reserved
CO-BLUE-CAT-0307Subject to change without prior notice.
For more information contact:
Siemens Water Technologies
10 Technology DriveLowell, MA 01851
North America and Canada800.875.7873 ext. 5000 Technical Support800.466.7873 Customer [email protected]
Information Desk800.525.0658 Toll Free+724.772.1402 [email protected]
www.siemens.com/water