Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l Up to 100m Depth l GPS Interface l PC Interface & Data Acquisition l pH l DO l Conductivity l Salt l TDS l Sea water SG l Temperature l Turbidity l Depth l ORP l Fluoride ions l Chloride ions l Nitrate ions l Calcium ions l Potassium ions l Ammonium ions l Chlorophyll Model WQC-24 -Water Quality Meter - Issue WQC-24-050225 Page 1

Transcript of Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24...

Page 1: Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l

Water Quality MeterModel WQC-24

DKK-TOA CORPORATION

l 35 Days Data Storagel Up to 11 Simultaneous Parametersl Up to 100m Depthl GPS Interfacel PC Interface & Data Acquisition

l pHl DOl Conductivityl Saltl TDSl Sea water SGl Temperaturel Turbidityl Depthl ORPl Fluoride ionsl Chloride ionsl Nitrate ionsl Calcium ionsl Potassium ionsl Ammonium ionsl Chlorophyll

Model WQC-24 -Water Quality Meter - Issue WQC-24-050225 Page 1

Page 2: Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l

The Model WQC-24 is the latest development in DKK-TOA’s range of multi-parameter water quality meters. The very latest technologies combined with more than 50 years experience have resulted in a compact, high performance and robust water quality monitoring system. The compact sensor probe can provide measurement of up to 11 parameters simultaneously out of a total of 17 available parameters. The instrument also features an interface port for connection to a Global Positioning System (GPS), Local Area Network (LAN), printer or other communication peripherals.

The Perfect Solution for Multiple Parameter Measurements

Meter SectionCompatible with all three types of sensor module

Model WQC-24 -Water Quality Meter - Issue WQC-24-050225Page 2

Standard Sensor Module

Standard & Ion Sensor Module

Standard & Chlorophyll Sensor Module

The Model WQC-24 can be used in a wide range of applications including:• Lakes• Agriculture• Industrial Effluent• Rivers• Wells, Underground Water• Fish Farming• Dams

Typical Applications

Page 3: Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l

Available parameters:• PH• DO• Conductivity• Salt• TDS• Seawater SG• Temperature• Turbidity(Total 8)

ORP available as an option (replaces pH sensor)

Available parameters:as per standard module, plus choice of any three of the following........• Fluoride Ion• Chloride Ion• Nitrate Ion• Calcium Ion• Potassium Ion• Ammonium Ion• ORP(Total 11)

Available parameters:as per standard module, plus• Chlorophyll sensor

Choice of any one of the following........• Fluoride Ion• Chloride Ion• Nitrate Ion• Calcium Ion• Potassium Ion• Ammonium Ion• ORP(Total 10)

Water depth sensor available as an option in all configurations. Addition of water depth sensor will extend dimensions of standard probe slightly (see page 6 for exact dimensions).

Model WQC-24 -Water Quality Meter - Issue WQC-24-050225 Page 3

Ion/ORP Sensors (3)

Optional WaterDepth Sensor *

Ion/ORP Sensor (1)Chlorophyll Sensor

Optional WaterDepth Sensor *

Temperature SensorTurbidity SensorDO SensorConductivity SensorpH Sensor

Location ofOptional WaterDepth Sensor *

Standard & Chlorophyll Sensor Module

*

Page 4: Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l

Features

pH Electrode with Easily Replaceable Chip Module

Multiple Parameter Combinations The sensor probe can measure up to 11 parameters out of 17 available (pH, ORP, DO, EC, Turbidity, Temperature, Salinity, Total dissolved solids, Specific gravity and Water depth plus Chlorophyll and Ions of NO3

-, Cl-, F-, Ca2+, K+, NH4

+).

Newly Developed High Performance SensorspH sensor is equipped with our “Strong” electrode and pressure compensator.New DO sensor is functional even under non-flowing conditions. Electrodes can be easily replaced using “chip” style components.

Compact Sensor Probe 45 mm outer diameter sensor probe fits into a 2-inch well (standard sensor module).

Robust Sensor Probe Sensor probe facilitates measurements as far as 100 meters below the water surface and up to a maximum pressure of 1 MPa (excluding ion sensors).Optional depth sensor enables measurement and collection of sensor depth information.

Data Logging Storage Capacity Exceeds One MonthBuilt-in memory stores measured data for 35 days of continuous measurements (based on measurement every 15 minutes or every hour for Chlorophyll measurement). The sensor module has its own internal memory and can be left disconnected from the meter section while continuing to measure and record data.

Interface Port Compatible with Global Positioning Systems (GPS)An interface port is provided as a standard feature for connection to GPS, Printer, LAN or other data communication peripherals (RS-232C).

PC Based Data Acquisition SoftwareOptional WQC-LOG software runs on any Windows® based personal computer. Measurement data can be saved to disk and/or exported to other applications (c,s,v, data format). Personal computer requires serial port or USB-serial port adapter.

Model WQC-24 -Water Quality Meter - Issue WQC-24-050225Page 4

Ref Electrode (ELR-001)

pH Glass Electrode Chip

Guard

Indi

catio

n Va

lue

(%)

Time (mins)

Flow No Flow Flow

Effect of Sample Flow Across DO Electrode

WQC-LOG Data Acquisition Software

Meter with Standard Sensor Module

Page 5: Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l

Description Model Measurement RangepH glass Electrode Chip ELP-023 pH 0 ~ 14

ORP Electrode Chip ELM-004 -2000 ~ 2000 mV

DO Electrode ELD-001 0 ~ 20 mg/L

Chloride Ion Electrode Chip CL-200B 1 ~ 35000 mg/L

Nitrate Ion Electrode Chip N-300 0.62 ~ 62000 mg/L

Fluoride Ion Electrode Chip F-200 0.019 ~ 19000 mg/L

Calcium Ion Electrode Chip CA-300 0.4 ~ 40000 mg/L

Potassium Ion Electrode Chip K-300B 0.39 ~ 3900 mg/L

Ammonium Electrode ELX-002 0.09 ~ 1800 mg/L

Measurement Item Standard Module Standard Module + Water Depth

Standard + Ion Module *1

Standard + Ion Module *1 + Water

Depth

Standard + Chlorophyll Module *2

Standard + Chlorophyll Module *2 + Water Depth

pH *3 ¥ ¥ ¥ ¥ ¥ ¥Dissolved Oxygen (DO) ¥ ¥ ¥ ¥ ¥ ¥Conductivity (COND) ¥ ¥ ¥ ¥ ¥ ¥Salt (SALT) ¥ ¥ ¥ ¥ ¥ ¥Total Dissolved Solids (TDS) ¥ ¥ ¥ ¥ ¥ ¥Seawater Specific Gravity (σ t) ¥ ¥ ¥ ¥ ¥ ¥Temperature (TEMP) ¥ ¥ ¥ ¥ ¥ ¥Turbidity (TURB) ¥ ¥ ¥ ¥ ¥ ¥ORP ¡ ¡ ¡ ¡ ¡ ¡Chlorophyll ¥ ¥Nitrate Ion ¡ ¡ ¡ ¡Chloride Ion ¡ ¡ ¡ ¡Calcium Ion ¡ ¡ ¡ ¡Fluoride Ion ¡ ¡ ¡ ¡Potassium Ion ¡ ¡ ¡ ¡Ammonium Ion ¡ ¡ ¡ ¡Water Depth ¥ ¥ ¥

Easily Replaceable Electrodes

Measured Parameters

Interface Examples

NOTES: *1 Maximum 3 optional items can be fitted. *2 Only one optional item can be fitted. *3 The pH sensor can be replaced by optional ORP sen-sor or an optional ORP sensor can be fitted to the second sensor head if simultaneous measurement of pH and ORP is required.

Model WQC-24 -Water Quality Meter - Issue WQC-24-050225 Page 5

Standard Sensor Module

Standard & IonSensor Module

Standard & Chloro-phyll Sensor Module

GPS ReceiverUnit

Windows® BasedPersonal Computer

RS232Printer

Examples of Electrodes (Each combined with reference electrode)

NOTE: The above electrodes are in “chip” style format and each require combination with ref. electrode, ELR-001 (except for Ammonium and DO sensors).

¥ Standard Parameter ¡ Available as an Option

Sensor Connecting Cable2m, 10m, 30m, 100m

Page 6: Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l

Code WMS24-1-00 WMS24-1-01 WMS24-1-10 WMS24-1-11 WMS24-1-20 WMS24-1-21

Product Name Standard sensor module

Standard sensor module (with water depth sensor)

Ion sensor module

Ion sensor module (with water depth sensor)

Chlorophyll module

Chlorophyll module (with water depth sensor)

Waterproof Construction Pressure resistant 1.0 MPa, waterproof *Memory Max. 3360 data (by sensor module)

Power Supply 3 x AA size batteries (approx 35 days life for 15 min measurement interval, or 1 hr interval for chlorophyll)

Outline Dimensions (excluding projections)

Approx. 45 dia x 411 (L) mm

Approx. 47 dia x 487 (L) mm

Approx. 52 (D) x 110 (W) x 510 (L) mm

Weight (excluding batteries) Approx. 1350g Approx. 1450g Approx. 2400g Approx. 2420g Approx. 2400g Approx. 2420g

Operating Temperature Range 0~50 deg C

Sensor Modules

Meter Section (Includes 2m Sensor Connecting Cable)

Dimensions

Code WQC24-1-0

Display LCD Digital

Waterproof Construction IP67 (JIS C 0920) Immersion proof (assuming cable is connected)

RS-232C Standard feature (non isolated when using with printer or GPS unit)

Analog Output (common) DC 0~1V, 3 points non-isolated:channels 1 & 2: outputs two selected parameters, channel 3: outputs the conductivity range

Open Collector Output (common) Alarm output: 1 point, DC 36V, 100mA or less Measurement timing output: 1 point, DC 36V, 100mA or less

Power Source 2 x AA size dry batteries or exclusive AC adapter (option)

Outline Dimensions (excluding projections) Approx. 187.5 (L) x 37.5 (H) x 75 (W) mm

Weight (excluding batteries) Approx. 320g

Operating Temperature Range 0~50 deg C

Model WQC-24 -Water Quality Meter - Issue WQC-24-050225Page 6

Meter Section Standard Sensor Module

Standard Sensor Module, With Op-

tional Depth Sensor

Chlorophyll Sensor Module **

Ion Sensor Module**

Dimensions of ion & chlorophyll sensor modules do not change when optional depth sensor is installed.

**

Sensor Cable Connector

Cover for Interface Connector

* Dummy caps are fitted to the empty electrode sockets. Please refer to the table on page 7 for information on individual ion electrode water depth limitations.

Page 7: Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l

Item Display Range Repeatability (main body)

Measurement Method Calibration

pH(or)ORP (option)

0.00 ~ 14.00 +/- 0.05 pH Glass electrode method 2 points of 4, 7, 9 or 3 points calibration

-2000 ~ 2000 mV +/- 5 mV Platinum electrode method ---

DO 0.00 ~ 20.00 mg/L/ 0 ~200 %

+/- 0.1 mg/L/ +/- 1 %

Galvanic membrane electrode method Zero & span calibration

COND 0.00 ~ 10.00 S/m (meter)0.0 ~ 100.0 mS/m (display),0.000 ~ 1.000 S/m (display),0.00 ~ 10.00 S/m (display), Auto & manual range selection

+/- 1 % FS AC 4-electrodes method Calibration is possible

SALT 0.00 ~ 4.00 % or0.0 ~ 40.0 (seawater salinity)

+/- 0.1 %+/- 1

Converted from conductivity value Calibration is possible

TDS 0.0 ~ 100.0 g/L +/- 2g/L Converted from conductivity value Calibration is possible

Seawater Specific Gravity

0.0 ~ 50.0 σt +/- 0.1 σt Converted from conductivity value Calibration is possible

TEMP -5.00 ~ 55.00 deg C +/- 0.25 deg C Thin film platinum resistance Calibration is possible

TURB 0.0 ~ 800.0 NTU/ 0.0 ~ 800.0 mg/L

+/- 3 % FS 90 degree scattered light method (infrared)

Zero & span calibration

Water Depth (DEPTH) (option)

0.0 ~ 100.0 m +/- 0.1 m Diaphragm pressure sensor method (built-in temp. compensation function)

Calibration is possible

Standard Sensor Module

Optional Ion Sensor Module (Available as Factory Configured Option Only)

Item Measurement Range Repeatability (main body)

Measurement Method Calibration

Nitrate ion (NO3-) 0.62 ~ 62000 mg/L +/- 5 % FS Ion electrodes method Dual point calibration

Chloride ion (Cl-) 1 ~ 35000 mg/L

Calcium ion (Ca2+) 0.4 ~ 40000 mg/L

Fluoride ion (F-) 0.019 ~ 19000 mg/L

Potassium ion (K+) 0.39 ~ 3900 mg/L

Ammonium ion (NH4+) 0.09 ~ 1800 mg/L

ORP -2000 ~ 2000 mV +/- 5 mV Platinum electrode method ---

Water depth (DEPTH) (option) 0.0 ~ 100.0 m +/- 0.1 m Diaphragm pressure sensor method (built-in temperature compensation function)

Calibration is possible

Item Ion Sensor Immersion Limit DepthNO3

-, NH4+ 5m

K+, Ca2+ 10m

F-, Cl- 15m

Ion Sensors Depth Limitation

Item Display Range Repeatability (main body) Measurement Method CalibrationChlorophyll 0.0 ~ 400.0 micro g/L --- Fluorescence method Calibration is possible

• Alkali dry batteries, AA size (LR6), 5 pcs• Buffer solutions for pH6.86 & pH4.01, 2 x 500 mL bottles• Reference electrolyte inner solution, 50mL bottle• Replacment junction for pH electrode, 1 pcs• Special tools (spanner, driver), 1 set• Membrane sets for DO electrode, 2 sets

• DO internal electrolyte solution, 50mL bottle• Calibration receptacles, 2 pcs• Connector cap, 1 pcs• Soft case (with shoulder belt), 1 pcs• Connection cable (2m), 1 pcs• Instruction manual, 1 copy

Standard Accessories

Optional Chlorophyll Sensor Module (Available as Factory Configured Option Only)

Model WQC-24 -Water Quality Meter - Issue WQC-24-050225 Page 7

Page 8: Water Quality Meter Model WQC-24dkktoa.net/pdf/wqc_24_broc.pdf · Water Quality Meter Model WQC-24 DKK-TOA CORPORATION l 35 Days Data Storage l Up to 11 Simultaneous Parameters l

Model WQC-24 -Water Quality Meter - Issue WQC-24-050225Page 8

International Operations:DKK-TOA Corporation29-10, 1-Chome, Takadanobaba, Shinjuku-ku, Tokyo 169-8648 JapanTel: +81-(0)3-3202-0225 Fax: +81-(0)3-3202-5685

Representative Offi ce (Europe):DKK-TOA European RepresentativeSt. Johns Innovation Centre, Cowley Rd., Cambridge CB4 0WS UK.Tel : +44 (0)1223-526471 Fax : +44 (0)1223-709239www.dkktoa.net www.toadkk.co.jp

Local Representative:

Always read the instruction manual before operation.

Due to continuous product improvement, specifi cations contained herein are subject to change without notice.

pH/ORP• pH Standard solution, pH 4.01 (500mL) 143F191• pH Standard solution, pH 6.86 (500mL) 143F192• pH Standard solution, pH 9.18 (500mL) 143F193• Reference electrode inner solution (50mL) 143F235• Reference liquid junction 6784580K• Glass electrode chip (pH) ELP-023• Reference electrode (for pH, ORP, Ion) ELR-001• ORP electrode chip ELM-004• ORP standard solution, 500mL + powder 143F196

DO• DO electrode electrolyte kit (50mL x 3) 0BG00007• DO membrane kit ( x 2 pcs) 6789790K• DO electrode unit ELD-001• Sodium sulfi te (50g) NA2SO3-5

ION • Reference electrode (pH, ORP, Ion) ELR-001• Reference electrode inner solution (50mL) 143F235• Reference liquid junction 6784580K• Ammonium electrode (with reference electrode) ELX-002• Ammonium electrode inner solution (50mL x 3) 0BG00005• Ammonium electrode diaphram cartridge (x 3) 6821890K• Fluoride ion electrode chip F-200• Chloride ion electrode chip CL-200B• Nitrate electrode chip N-300• Potassium electrode chip K-300B• Calcium electrode chip CA-300• Ammonium ion standard solution 1000mg/L (500mL) NH4-1000• Ammonium-nitrogen std. solution 1000mg/L (500mL) NH4-N• Fluoride ion standard solution 1000mg/L (500mL) F-1000• Chlorine ion standard solution 1000mg/L (500mL) CL-1000• Nitrate ion standard solution 1000mg/L (500mL) NO3-1000• Nitrate-nitrogen standard solution 1000mg/L (500mL) NO3-N• Potassium ion standard solution 1000mg/L (500mL) K-1000• Calcium ion standard solution 1000mg/L (500mL) CA-1000• Strength adjuster for ammonia ion solution (500mL) ISA-NH• Strength adjuster for fl uoride ion solution (500mL) TISAB-01• Strength adjuster for fl uoride ion solution (500mL) TISAB-11• Strength adjuster for chlorine solution (500mL) ISA-CL• Strength adjuster for nitrate solution (500mL) ISA-NO• Strength adjuster for potassium solution (500mL) ISA-K• Strength adjuster for calcium ion solution (500mL) ISA-CA

General• Connection cable, 2m 6801640K• Connection cable, 10m 6821850K• Connection cable, 30m 6821860K• Connection cable, 100m 6821870K• RS-232C cable (1m) 0GC00005• RS-232C cable (2m) 0GC00006• RS-232C cable (4m) 0GC00007• RS-232C cable (10m) 0GC00008• Data Control Software WQC-LOG• Analogue output cable, 1.5m 6548270K• Printer with cable EPS-G• Printer paper (20 Rolls) P000119• Printer ink ribbon 0RD00001• AC adapter (specify your supply voltage) 134G022• GPS unit with connecting cable 6812970K

Options & Accessories

Code DescriptionWQC24-1-0 Main meter section only (with 2m cable)WQC24-1-1 Standard sensor module + meter (with 2m cable)WQC24-1-2 Standard + ion sensor module + meter (with 2m cable)WQC24-1-3 Standard + chlorophyll sensor module + meter (with 2m cable)WQC24-1-4 Standard sensor module (with water depth sensor) + meter (with

2m cable)WQC24-1-5 Standard + ion sensor module (with water depth sensor) +

meter (with 2m cable)WQC24-1-6 Standard + chlorophyll sensor module (with water depth sensor)

+ meter (with 2m cable)

Code DescriptionWMS24-1-00 Standard sensor moduleWMS24-1-10 Standard + ion sensor moduleWMS24-1-20 Standard + chlorophyll sensor moduleWMS24-1-01 Standard + chlorophyll sensor module (with water depth sensor)WMS24-1-11 Standard + ion sensor module (with water depth sensor)WMS24-1-21 Standard + chlorophyll sensor module (with water depth sensor)

Connection Cables, Electrodes• Connection cable, 10m 6821850K• Connection cable, 30m 6821860K• Connection cable, 100m 6821870K• Reference electrode ELR-001• ORP electrode chip ELM-004• Fluoride ion electrode F-200• Chloride ion electrode CL-200B• Nitrate electrode N-300• Potassium electrode K-300B• Calcium electrode CA-300• Ammonium electrode (with reference electrode) ELX-002

Meter and Sensor Module Combinations

Main Equipment Order Codes

Sensor Modules Only

NOTES: (1) Connection cables and ion/ORP electrodes must be purchased sepearately, please refer to the items described below. (2) One reference electrode chip is required for each ion/ORP sensor used. (3) Ammonia sensor is a complete unit and does not require seperate purchase of reference electrode.

NOTE FOR ION MEASUREMENT: For ion measurements, we reccommend that the sample is fi rst collected in a container and then measurement carried out in the sample container.