WALL TYPE REGISTERS & GRILLES

APPLICATION

Shahrokhi wall type registers & grilles are

designed to suit H.V.A.C. applications where

a high side wall or exposed duct is required.These registers used for adjusting air flow

patterns of airconditioned spaces and yet

with an architectural appearance.Shahrokhi wall type registers & grilles with

one or two way adjustable blades used for

supply, return or exhaust air.

DESCRIPTION

Multi parallel and adjustable blades with

aerofoil section of blades which construct in

one or two row(stage) allow a smooth and

uniform pressure drop applications.Adjustable horizontal or vertical blades can

be supplied to control the air flow pattern in

either the horizontal or vertical planes.

BLADES

Blades may be fixed at any position as

optional during construction which named

fixed type. Either the blades may be moved

at any position which adjust manualy and

named moved type.

oP«j¬°kM ° nAjoP«j ºnA±½j ºBµ³`½nj

ºoMnB�

S´] »ioµBÇ{ oÇP«j¬°kM ° nAjoÇP«j ºnA±Ç½j ºBǵ³`½nj

³� »½B´¯Bñ« nj �±L�« ³½±´U Sí®æ nj KwB®« ºBµºoMnB�

/k¯A²k{ »ÇeAoÇ� k{BM pBǼ¯ nBÇ�°n »§BǯBÇ� B½ k®¦M ºnA±Ç½j

ºBǵB�� ºA±µ »ÇMj nAkÇ�« ©¼�®U S´] Bǵ³`½nj �±¯ ­Ç½A

²jB�TwA jn±« ºnBÇªí« ºBÇ´½pBwBǪ¯ ­¼®`ªµ ° ²k{ ³½±´U

/k¯o¼£»« nAo�

B½ ð½ BM »ioµB{ oP«j¬°kM ° nAjoP«j ºnA±½j ºBǵ³`½nj

Sz£oÇÇÇM ,S�n ºA±Çǵ S´Ç] ©¼�Ç®U ¥MBÇÇ� ²oÇQ �ǽjn °j

/k¯±{»« ²jB�TwA ³¼¦hU °

RBd¼�±U

é�Ç�« c�Çw BM ºpA±ÇÇ« Rn±æ ³M ³� A±Çǵ ©¼�®ÇU ºBµ²oÇÇQ

nAoÇÇ� ©µ nBÇÇ®� �ǽjn °j B½ ð½ nj A±Çµ n±Lî S´] KwB®«

A±Çǵ ¬BÇǽo] ³� kǯn°C»ÇÇ« j±]° ³M An ¬Bñ«A ­½A k¯o¼£»«

n±ÇLî ©� nBÇz� S�A ° y«AnC BÇ M ²AoǪµ ,SiA±®ñǽ Rn±~M

/k®½Bª¯

ºj°ªî B½ »Ç��A ºBÇ´Un±æ ³M k®¯A±U»Ç« A±Çµ ©¼�®U ºBµ²oQ

ºBµ³½¿ nj An ºn±Lî ºA±Çµ ³\¼T¯ nj ° k¯o¼¢M nAo� ©µ nB®�

/k®½Bª¯ ¤BwnA ºj±ªî B½ »��A

Bµ²oQ

Rn±~M ºA³Ç½°Ap oǵ nj Bǵ²oÇQ ³Ç� jnAj j±Ç]° ¬Bñ«A ­Ç½A

SMBÇY �±Çǯ ³� k¯±{ SMBÇÇY SiBw ¥eAoÇ« »Ç� nj »MBÇhT¯A

/k¯A²k{ ºnAm¢«B¯

Rn±~M ºA³Ç½°Ap oǵ nj Bµ²oÇÇQ ­ÇǽA SwA ­Çñª« ­Ç¼®`ªµ

/k¯A²k{ ºnAm¢«B¯ �odT« �±¯ ³� k®{BM ©¼�®U ¥MB�»Twj

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI 1

Page 3: Wall Type Registers

FRAME

Four types of frames are available up on

request (figure 2).Select the type of frame is relative to

installation of grilles location.

Three types of blades used (figure 1).Nylon busing or line spring are used to

seperate the blades from the frame to

eliminate rattling and to provide positive

tension when adjusting them.

JB�

toÇÇÇÇTwjnj SwA±Çinj ³M BÇ®M (2 ¥ñ{) JBÇÇ� �±Ç¯ nBÇ´a

/k{BM»«

/jnAj »¢TvM Bµ³`½nj K~¯ ¥d« ³M JB� �±¯ JBhT¯A

S´Ç] /k¯o¼£»« nAo� ²jBÇ�TwA jn±« (1 ¥ñ{) ²oQ �±¯ ³w

ºBµx±ÇM pA Akæ �me n±�Ç®« ³M JBÇ� pA Bµ²oÇQ ¬j±ª¯ Ak]

K¼UoÇU ­½kM ° j±{»« ²jBÇÇ�TwA »�i oÇ®� Bǽ ° »ñ¼TwÀQ

/k¯o¼£»« nAo� yz� º°oÇǼ¯ SdÇU Bµ²oÇQ ,©¼�®U ¬B«p nj

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

27.0 mm. 32.0

mm.

47

.0

mm

.

(FIGURE 2)

(A) (B) (C) (D)

17

.0 m

m.

18

.0 m

m.

(FIGURE 1)

(1) (2) (3)

2

Page 4: Wall Type Registers

ORDERING CODE

MATERIAL & FINISH

High quality 1.25 mm thickness extruded

aluminium profile in matt aluminium

anodized finish for blades and frame.It is possible to used iron instead of

aluminium up on request.White polyester liquid or powder coating and

finish is also available or any other specified

color with raul code up on requirement.

Shahrokhi wall type registers & grilles with

following ordering code specified.

¡¯n ° jA±«

xnB�w k�

S«BÇh� ³M »Çzz� ¨±ÇǼ®¼«±Ç§C ¥¼�°oÇQ pA BµJB� ° Bµ²oÇQ

S¼�¼� BM ¨±ÇǼ®¼«±Ç§C ²k{ q½AjBÇǯC y�°n BM oÇTª¼¦¼« 1.25

/k¯±{»« ³¼´U KwB®«

SwA±inj ³M BÇ®M q¼¯ ¨±¼®¼«±Ç§C ºB\M ­µC pA ²jB�TwA ¬Bñ«A

/jnAj j±]°

y{BQ x°n ³M »½B´¯ ºqǼ«C ¡¯n ³� jnAj j±]° ¬Bñ«A ­½A

pA ²jBÇÇ�TwA BÇM (ð¼UBÇTwA°oÇTñ§A )ºnj±ÇÇÇQ B½ éÇǽBÇ« ¡Ç¯n

}hz« ¤An ²nBǪ{ BM ºo¢Ç½j ¡¯n oǵ B½ k¼�w oÇTwA»Ç¦Q

/j±{ ¨B\¯A pB¼¯ ³M ³]±ÇU BM

k� BM »ioµB{ oÇP«j ¬°kM ° nAjoÇP«j ºnA±Ç½j ºBǵ³`½nj

/k¯±{»« }hz« o½p xnB�w

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

SH.WRE.T-WXHx

»ioµB{ ³¯BinB� :SH

oP«j¬°kM ° nAjoP«j ºnA±½j ³`½nj :WRE

³�o�ñ½ SMBY ©¼�®U ¥MB� ºBµ²oQ BM ºnA±½j ³`½nj : A1F ³`½nj �±¯ :T

( A 1Fnj ²j B�TwA S ´] � ��) (³ ]nj) ²o Q ³½ °Ap x (_ ®½A) ç oî x (_ ®½A) � B�UnA : W XHx

³�o�ñ½ �odT« ©¼�®U ¥MB� ºBµ²oQ BM ºnA±½j ³`½nj :A1M

³� o� °j ©¼ �®U ¥M B� ºB µ²oQ BM º n A±½j ³ ̀ ½nj :A 2

SH : Shahrokhi manufacture

WRE : Wall type register & grille

T : type : A1F : Fixed type one way adjustable blade (single deflection)

A1M : Moved type one way adjustable blade (single deflection)

A2 : Two way adjustable blade (double deflection)

WXHx : Width (inch) x height (inch) x blade angle (deg) (only for A1F)

3

Page 5: Wall Type Registers

SH.WRE.A1F & A1M

Shahrokhi wall type registers with one way

adjustable blades (figure 3) have multi

parallel blades which can be fixed or moved

around the auxial pins.These registers used for supply , return or

exhaust air.Horizontal or vertical blades may be

arranged for any deflect setting position.To see the air flow pattern for different

blades setting refer (figure 4).

�odT« ° SMBY ³�o�ñ½ ºnA±½j ºBµ³`½nj

©¼�®U ¥MB� ²oQ �½jn ð½ BM »ioµBÇ{ ºnA±Ç½j ºBǵ³`½nj

Bǵ²oQ ­½A ¬A±ÇU»« ³� k¯nAj ºpA±Ç« ²oQ ºjAkíU (3 ¥ñ{)

/j±ª¯ SMBY B½ �odT« j±i ºq�o« n±d« ¤±e An

jn±ÇÇ« ³Ç¼¦hU ° Sz£oM ,S�n ºA±Çǵ S´] BÇǵ³`½nj ­ÇǽA

SwA ­ñª« ºj±ªî B½ »��A ºBµ²oQ /k¯o¼£»« nAo� ²jB�TwA

/k¯o¼£ nAo� ºA³Çǽ°Ap oÇǵ nj

²k{ ©¼�®U �¦Th« ºBÇǽA°p nj A±Çǵ ¬Bǽo] ²kµBz« S´]

/j±{ ³í]Ao« (4 ¥ñ{) ³M Bµ²oQ

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

AL L DIME NS ION IN mm.

F IX E D

OR

MOV E D

17

.0

20..0

L I S T E D S I Z E -12..5

(FIGURE 3)

4

A1MA1F

Page 6: Wall Type Registers

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

75 <20

100 <20

125 <20

150 <20

175 <20

200 <20

225 <20

250 <20

100 <20

150 <20

200 <20

250 <20

300 <20

350 <20

400 <20

450 <20

100 20

150 20

200 21

250 21

300 21

350 22

400 22

450 22

150 20

200 20

250 21

300 21

350 22

400 22

450 23

500 23

150 20

225 21

300 21

375 22

450 22

525 23

600 23

675 24

150 20

225 21

300 21

375 22

450 22

525 23

600 23

675 24

268

357

446

536

626

714

804

893

250

375

500

625

750

875

1000

1125

233

349

465

581

698

814

930

1047

300

400

500

600

700

800

900

1000

246

369

492

615

738

861

984

1107

231

346

462

577

692

808

923

1038

0.032

0.051

0.077

0.108

0.143

0.188

0.242

0.287

0.029

0.055

0.096

0.143

0.210

0.278

0.360

0.448

0.025

0.049

0.083

0.124

0.179

0.247

0.311

0.393

0.039

0.060

0.096

0.130

0.180

0.240

0.290

0.360

0.028

0.053

0.093

0.138

0.203

0.271

0.349

0.435

0.025

0.049

0.082

0.122

0.176

0.244

0.306

0.387

200 20

275 21

350 21

425 22

500 22

575 23

650 23

725 23

250 20

325 21

400 21

475 22

550 22

625 23

700 23

775 24

350 20

450 21

550 22

650 23

750 23

850 24

950 25

1050 26

425 20

550 22

675 24

800 25

925 26

1050 28

1175 29

1300 30

400 20

550 20

700 21

850 21

1000 22

1150 22

1300 23

1450 23

450 20

600 23

750 25

900 27

1050 28

1200 29

1350 30

1500 31

282

387

493

599

704

810

975

1021

313

406

500

594

688

781

875

969

324

417

509

602

694

787

880

972

324

420

515

611

706

802

897

992

292

401

511

620

730

839

949

1058

290

387

484

581

677

774

871

968

0.035

0.057

0.093

0.130

0.182

0.245

0.301

0.375

0.042

0.062

0.096

0.128

0.174

0.229

0.278

0.338

0.044

0.066

0.099

0.131

0.177

0.232

0.280

0.340

0.044

0.067

0.101

0.136

0.184

0.241

0.289

0.354

0.037

0.060

0.100

0.140

0.198

0.260

0.324

0.401

0.037

0.057

0.090

0.124

0.169

0.224

0.276

0.388

24"x8"

20"x10"

16"x12"

AK=0.71

36"x6"

18"x12"

16"x14"

AK=0.80

24"x10"

20"x12"

AK=1.08

36"x8"

24"x12"

AK=1.31

30"x10"

AK=1.37

24"x14"

AK=1.55

450 20

625 22

800 24

975 26

1150 28

1325 30

1500 31

1675 33

700 20

950 23

1200 26

1450 30

1700 33

1950 37

2200 40

2450 42

800 20

1050 22

1300 25

1550 28

1800 31

2050 34

2300 36

2550 38

925 20

1225 22

1525 25

1825 28

2125 31

2425 35

2725 38

3025 40

1000 20

1350 22

1700 25

2050 28

2400 31

2750 35

3100 38

3450 40

1250 20

1650 23

2050 26

2450 30

2850 33

3250 37

3650 40

4050 42

36"x10"

30"x12"

20"x18"

AK=1.64

36"x14"

AK=2.40

24"x24"

AK=2.64

36"x18"

AK=3.08

30"x24"

AK=3.38

36"x24"

AK=4.07

274

381

488

595

701

808

915

1021

292

396

500

604

708

813

917

1021

303

398

492

587

682

777

871

966

300

398

495

593

690

787

885

982

296

399

503

607

710

814

917

1020

307

405

504

602

700

799

897

995

0.034

0.056

0.092

0.128

0.181

0.244

0.301

0.375

0.037

0.059

0.096

0.132

0.185

0.247

0.302

0.375

0.040

0.060

0.093

0.126

0.171

0.226

0.276

0.336

0.039

0.060

0.094

0.128

0.175

0.232

0.283

0.347

0.038

0.060

0.097

0.134

0.186

0.247

0.302

0.375

0.040

0.062

0.097

0.131

0.180

0.239

0.289

0.357

SH.WRE.A1F&A1MENGINEERING PERFORMANCE DATA ³�o�ñ½ ºnA±½j ºBµ³`½nj RBLwBd« ¤°k]

5

All NC levels given are based on 10db room absorption

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M

NEGATIVE

ST.PRESS.

IN.W.G.

N.C.

VELOCITY

F.P.M

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M

NEGATIVE

ST.PRESS.

IN.W.G.

N.C.

VELOCITY

F.P.M

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M

NEGATIVE

ST.PRESS.

IN.W.G.

N.C.

VELOCITY

F.P.M

12"x6"

AK=0.28

16"x6"

12"x8"

AK=0.40

18"x6"

AK=0.43

20"x6"

16"x8"

12"x10"

AK=0.50

24"x6"

18"x8"

12"x12"

AK=0.61

30"x8"

18"x10"

AK=0.65

Page 7: Wall Type Registers

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

(FIGURE 4)

Z E R O DEG DE F L E CT ION

22.5 DEG DE F L E CT ION 45 DEG DE F L E CT ION

0' 5' 10' 15' 20' 25' 30' 40' 45' 50' 55' 60'35'

35' 45'40'30'25'20'15'10'5'0' 30'25'20'15'10'5'0'

DR

OP

L

T H R OW=3/ 4 L

02

24

24

22

2

22

02

2S

TR

AIG

HT

0'

10'

10'

10'

0'

10'

10'

0'

10'

The (figure 4) shows the air flow pattern for

different blades setting. It is noted that the

throw and drop will decrease as the angle of

the deflection increased.The blades will affect the spread as fallows: a) For 0 deg deflection (straight) angle, the

total spread of the air stream is one-third of

the throw.b) For 22.5 deg deflection angle, the total

spread of the air stream is about 45 percent

of the throw.c) For 45 deg deflection angle, the total

spread of the air stream is two-third of the

throw.

²k{ ©¼�®ÇU �¦Th« ºBÇǽA°p nj An A±Çǵ ¬BÇǽoÇ] (4 ¥ñ{)

³½°Ap ³� »¯BÇÇ«p jjoÇÇ£»ÇÇ« ²kµBÇÇz« /kµj»« ¬Bz¯ Bµ²oQ

/k®MB½»« yµB� �±�w ° ³MBUoQ o½jB�« k®�»« Ak¼Q y½Aq�A

:k{BM»« ¥½l bozM Bµ²oQ ³½°Ap ³�wA±M A±µ yhQ

A±Çµ »¦� yhQ Bǵ²oQ (©¼�Tv«) ³]nj o�æ ³½°Ap nj (�§A

/k{BM»« ³MBUoQ ¤jBí«

45 ¤jBÇí« A±Çµ »¦� yhQ Bǵ²oÇQ ³]nj 22.5 ³½°Ap nj (J

/k{BM»« ³MBUoQ kænj

¤jBÇíÇ« A±Çǵ »Ç¦� yhQ Bǵ²oÇÇQ ³]nj 45 ³½°Ap nj (Z

/k{BM»« ³MBUoQ

A2A1MA1F

6

,

,

,

13

23

Page 8: Wall Type Registers

SH.WRE.A2

Shahrokhi wall type registers with two way

adjustable blades (figure 5) have multi

parrallel blades in vertical and horizontal

which can be moved around the auxial pins.These registers used for supply, return or

exhaust air.Horizontal and vertical blades can be moved

at any deflect setting position.To see the air flow pattern for different

blades setting refer (figure 4).

³�o� °j ºnA±½j ºBµ³`½nj

©¼�®U ¥MB� ²oÇQ �½jn °j BM »ioµBÇ{ ºnA±Ç½j ºBµ³`½nj

³� kǯnAj ºj±Çªî ° »Ç��A ºpA±ÇÇ« ²oÇQ ºjAkÇÇíU (5 ¥ñ{)

ºq�o« n±Çd« ¤±e ºA³Ç½°Ap oÇǵ nj An Bµ²oÇÇQ ­½A ¬A±U»Ç«

Sz£oM ,S�n ºA±Çµ S´] Bǵ³`½nj ­ÇǽA /jAj S�oe j±i

/k¯o¼£»« nAo� ²jB�TwA jn±« ³¼¦hU °

S�oe k®¯A±ÇÇU»« ºA³Ç½°Ap oǵ nj ºj±Çªî ° »Ç��A ºBµ²oÇQ

/k®½Bª¯

²k{ ©¼�®U �¦Th« ºBÇǽA°p nj A±Çǵ ¬Bǽo] ²kµBz« S´]

/j±{ ³í]Ao« (4 ¥ñ{) ³M Bµ²oQ

(FIGURE 5)

AL L DIME NS ION IN mm.

F IX E D

OR

MOV E D

17

.0

20..0

L I S T E D S I Z E -12..5

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI 7

,

Page 9: Wall Type Registers

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

19 14 12

20 16 14

27 23 19

33 27 22

37 31 26

42 35 29

45 41 32

50 43 34

18 13 11

21 16 14

28 24 21

35 29 25

41 34 28

46 38 31

50 44 35

54 45 37

19 14 12

23 19 16

29 24 21

35 30 25

41 34 28

47 38 31

51 43 34

54 44 36

20 14 12

24 19 16

31 25 20

37 31 25

44 33 29

51 37 33

54 45 35

56 45 37

20 14 12

27 22 18

36 30 25

43 25 30

50 40 35

56 44 40

60 49 41

62 51 44

20 14 12

27 22 18

35 29 24

42 35 30

53 41 37

56 44 40

59 49 42

61 50 43

0.005 0.007 0.008

0.010 0.013 0.016

0.016 0.022 0.027

0.024 0.032 0.040

0.034 0.045 0.056

0.045 0.060 0.074

0.058 0.077 0.095

0.073 0.096 0.119

0.004 0.005 0.006

0.009 0.012 0.014

0.016 0.021 0.026

0.024 0.032 0.040

0.035 0.046 0.058

0.048 0.063 0.078

0.062 0.082 0.102

0.079 0.104 0.129

0.004 0.006 0.007

0.009 0.011 0.014

0.015 0.019 0.024

0.022 0.029 0.036

0.031 0.041 0.050

0.041 0.054 0.067

0.053 0.070 0.087

0.066 0.087 0.109

0.004 0.005 0.007

0.009 0.012 0.015

0.016 0.021 0.026

0.025 0.033 0.041

0.036 0.048 0.059

0.049 0.065 0.081

0.064 0.085 0.106

0.082 0.108 0.134

0.005 0.007 0.008

0.010 0.014 0.017

0.018 0.023 0.029

0.027 0.035 0.044

0.038 0.050 0.062

0.051 0.067 0.084

0.066 0.087 0.108

0.083 0.109 0.136

0.005 0.007 0.008

0.010 0.014 0.017

0.017 0.023 0.028

0.026 0.034 0.042

0.036 0.048 0.059

0.048 0.063 0.079

0.062 0.082 0.102

0.077 0.102 0.127

250 284

350 398

450 511

550 625

650 739

750 852

850 966

950 1080

250 250

375 375

500 500

625 625

750 750

875 875

1000 1000

1125 1125

300 263

425 373

550 482

675 592

800 702

925 811

1050 921

1175 1031

300 254

450 381

600 508

750 636

900 763

1050 890

1200 1017

1350 1144

400 284

575 408

750 532

925 656

1100 780

1275 904

1450 1028

1625 1152

425 287

600 405

775 524

950 642

1125 760

1300 878

1475 997

1650 1115

20

21

21

22

22

23

23

24

20

21

21

22

22

23

23

23

20

21

21

22

22

23

23

24

20

21

22

23

23

24

25

26

20

22

24

25

26

28

29

30

20

20

21

21

22

22

23

23

30"x6"

18"x10"

AK=0.88

24"x8"

20"x10"

16"x12"

AK=1.00

36"x6"

18"x12"

16"x14"

AK=1.14

30"x8"

24"x10"

20"x12"

18"x14"

AK=1.18

36"x8"

24"x12"

20"x14"

AK=1.41

30"x10"

AK=1.48

ST.PRESS. ST.PRESS. ST.PRESS.THROW THROWTHROW

0 DEG 22.5 DEG 45 DEG

IN.W.G. IN.W.G.IN.W.G.FT. FT. FT.

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M F.P.M

N.C.

VE

LO

CIT

Y

13 10 9

15 12 11

17 14 12

21 17 14

25 20 16

28 23 18

33 26 21

38 30 25

17 14 12

18 15 13

21 18 15

24 21 17

27 23 19

30 25 21

33 27 23

36 30 26

15 11 9

18 14 12

20 17 15

26 23 20

32 27 23

38 32 27

43 37 31

52 44 37

17 13 11

19 16 14

22 19 17

28 25 21

34 29 25

38 32 27

44 38 32

52 44 37

19 16 14

23 20 18

28 24 20

32 26 22

37 32 27

41 35 29

44 40 32

51 43 37

18 13 11

21 16 14

26 22 18

32 27 23

39 33 28

44 37 31

50 45 38

55 46 38

0.002 0.002 0.003

0.007 0.009 0.011

0.016 0.021 0.026

0.028 0.037 0.045

0.048 0.057 0.071

0.062 0.082 0.102

0.085 0.112 0.139

0.111 0.146 0.182

0.007 0.049 0.012

0.013 0.017 0.021

0.020 0.027 0.033

0.029 0.038 0.048

0.039 0.052 0.065

0.052 0.068 0.084

0.065 0.086 0.107

0.081 0.106 0.132

0.003 0.004 0.005

0.009 0.012 0.015

0.018 0.024 0.030

0.031 0.041 0.051

0.047 0.062 0.077

0.066 0.088 0.109

0.089 0.118 0.146

0.115 0.152 0.189

0.005 0.007 0.009

0.012 0.016 0.020

0.022 0.028 0.035

0.034 0.044 0.055

0.049 0.064 0.080

0.066 0.087 0.108

0.086 0.114 0.142

0.109 0.144 0.179

0.008 0.011 0.014

0.014 0.019 0.023

0.022 0.028 0.035

0.030 0.040 0.050

0.041 0.054 0.067

0.053 0.070 0.086

0.066 0.087 0.108

0.081 0.107 0.133

0.004 0.005 0.007

0.009 0.012 0.015

0.016 0.021 0.026

0.025 0.033 0.041

0.036 0.047 0.059

0.049 0.065 0.080

0.064 0.084 0.105

0.081 0.107 0.133

50 167

100 333

150 500

200 667

250 833

300 1000

350 1167

400 1333

150 341

200 455

250 568

300 682

350 795

400 909

450 1023

500 1136

100 217

175 380

250 543

325 707

400 870

475 1033

550 1196

625 1359

150 294

225 441

300 588

375 735

450 882

525 1029

600 1176

675 1324

250 368

325 478

400 588

475 699

550 809

625 919

700 1029

775 1140

200 253

300 380

400 506

500 633

600 759

700 886

800 1013

900 1139

<20

<20

<20

<20

<20

<20

<20

<20

<20

<20

<20

<20

<20

<20

<20

<20

20

20

21

21

21

22

22

22

20

20

21

21

22

22

23

23

20

21

21

22

22

23

23

24

20

21

21

22

22

23

23

24

12"x6"

AK=0.30

16"x6"

12"x8"

AK=0.44

18"x6"

AK=0.46

20"x6"

12"x10"

AK=0.51

24"x6"

18"x8"

12"x12"

AK=0.68

20"x8"

16"x10"

AK=0.79

ST.PRESS. ST.PRESS. ST.PRESS.THROW THROWTHROW

0 DEG 22.5 DEG 45 DEG

IN.W.G. IN.W.G.IN.W.G.FT. FT. FT.

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M F.P.M

N.C.

VE

LO

CIT

YSH.WRE.A2

ENGINEERING PERFORMANCE DATA ³�o�°j ºnA±½j ºBµ³`½nj RBLwBd« ¤°k]

8

Page 10: Wall Type Registers

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

- 0 , 22.5 , 45 are spreading angles (deflection settings).

- Throw is given in feet for 50 F.P.M. terminal velocity.

- All NC levels given are based on10db room absorption.

- All NC, static pressure and AK values given are for single deflection registers with fully open damper and at zero degree deflection.

35 30 25

43 37 31

54 45 37

60 49 40

66 53 44

72 57 49

75 60 50

76 61 51

37 31 26

45 38 32

55 46 36

61 50 40

66 54 44

73 57 48

75 59 50

76 60 51

40 34 28

49 41 34

57 46 37

65 55 45

73 63 52

79 68 57

85 74 62

88 77 65

0.007 0.009 0.011

0.013 0.017 0.021

0.021 0.028 0.035

0.032 0.042 0.052

0.044 0.059 0.073

0.059 0.078 0.097

0.076 0.100 0.124

0.095 0.125 0.155

0.007 0.010 0.012

0.014 0.018 0.022

0.022 0.029 0.036

0.032 0.043 0.053

0.044 0.059 0.073

0.059 0.077 0.096

0.075 0.098 0.122

0.093 0.122 0.152

0.006 0.008 0.011

0.013 0.017 0.021

0.021 0.027 0.034

0.031 0.041 0.051

0.043 0.057 0.071

0.058 0.076 0.095

0.074 0.098 0.012

0.092 0.122 0.152

950 328

1325 457

1700 586

2075 716

2450 845

2825 974

3200 1103

3575 1233

1100 344

1500 469

1900 594

2300 719

2700 844

3100 969

3500 1094

3900 1219

1250 321

1750 449

2250 577

2750 705

3250 833

3750 962

4250 1090

47501218

20

23

25

27

28

29

30

31

20

22

24

26

28

30

31

33

20

23

26

30

33

37

40

42

36"x18"

AK=2.90

30"x24"

AK=3.20

36"x24"

AK=3.90

ST.PRESS. ST.PRESS. ST.PRESS.THROW THROWTHROW

0 DEG 22.5 DEG 45 DEG

IN.W.G. IN.W.G.IN.W.G.FT. FT. FT.

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M F.P.M

N.C.

VE

LO

CIT

Y

20 13 11

27 22 18

35 28 24

43 36 30

50 40 35

55 44 39

59 49 41

61 51 43

25 17 16

33 28 23

37 31 25

44 37 30

52 43 36

59 47 40

64 53 44

65 55 45

26 17 15

34 26 21

40 33 29

47 40 32

52 44 35

60 47 40

65 53 44

67 55 45

30 24 21

39 32 27

47 39 33

53 44 36

60 49 40

66 52 45

69 56 47

71 58 48

28 22 19

39 32 27

45 37 31

53 45 36

61 49 40

67 52 45

70 56 47

72 58 48

31 25 21

40 33 27

46 38 32

56 46 37

60 50 42

67 52 45

72 58 49

73 59 50

0.005 0.006 0.008

0.010 0.013 0.016

0.017 0.022 0.027

0.025 0.033 0.041

0.036 0.047 0.059

0.048 0.064 0.079

0.062 0.082 0.102

0.078 0.103 0.129

0.006 0.008 0.010

0.011 0.014 0.018

0.017 0.023 0.028

0.025 0.034 0.042

0.035 0.046 0.058

0.046 0.061 0.076

0.059 0.078 0.097

0.073 0.097 0.120

0.005 0.006 0.008

0.009 0.013 0.016

0.016 0.021 0.026

0.024 0.032 0.039

0.034 0.044 0.055

0.045 0.059 0.074

0.058 0.076 0.095

0.072 0.096 0.119

0.005 0.006 0.008

0.010 0.013 0.016

0.017 0.022 0.028

0.026 0.034 0.042

0.036 0.048 0.059

0.048 0.064 0.079

0.062 0.082 0.102

0.078 0.103 0.128

0.005 0.006 0.008

0.010 0.013 0.017

0.017 0.023 0.029

0.027 0.036 0.044

0.038 0.051 0.063

0.052 0.068 0.085

0.067 0.089 0.110

0.085 0.112 0.139

0.006 0.008 0.010

0.012 0.016 0.020

0.021 0.027 0.034

0.032 0.042 0.052

0.045 0.059 0.073

0.060 0.079 0.098

0.078 0.102 0.127

0.097 0.129 0.160

450 273

650 394

850 515

1050 636

1250 758

1450 879

1650 1000

1850 1121

550 306

750 417

950 528

1150 639

1350 750

1550 861

1750 972

1950 1083

600 275

850 390

1100 505

1350 619

1600 734

1850 849

2100 963

2350 1078

700 280

1000 400

1300 520

1600 640

1900 760

2200 880

2500 1000

2800 1120

700 275

1025 402

1350 529

1675 657

2000 784

2325 912

2650 1039

2975 1167

800 308

1150 442

1500 577

1850 712

2200 846

2550 981

2900 1115

3250 1250

20

23

25

27

28

29

30

31

20

22

24

26

28

30

31

33

20

23

26

30

33

37

40

42

20

23

26

30

33

37

40

42

20

23

26

30

33

37

40

42

20

22

25

28

31

34

36

38

24"x14"

AK=1.65

36"x10"

30"x12"

20"x18"

AK=1.80

36"x12"

30"x14"

24"x18"

AK=2.18

36"x14"

AK=2.50

30"x18"

AK=2.55

24"x24"

AK=2.60

ST.PRESS. ST.PRESS. ST.PRESS.THROW THROWTHROW

0 DEG 22.5 DEG 45 DEG

IN.W.G. IN.W.G.IN.W.G.FT. FT. FT.

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M F.P.M

N.C.

VE

LO

CIT

YSH.WRE.A2

ENGINEERING PERFORMANCE DATA ³�o�°j ºnA±½j ºBµ³`½nj RBLwBd« ¤°k]

9

Page 11: Wall Type Registers

EGG WALL REGISTERS & GRILLES

APPLICATION

DESCRIPTION

BIADES & FRAME

Shahrokhi egg wall registers & grilles are

designed to suit H.V.A.C. applications where

a high side wall or exposed duct is required.

they are mainly applicable when high air

volume at low pressure is desired.Their attractive appearance make them

suitable for other architectural and

decoration applications.

Multi parallel blades of these grilles adjust

in vertical and horizontal to control the air

flow. These grilles are an aluminium core

which constructed in three types of fixed

egg crate grid opening.

It is possible to fixed at 0, 30 and 45 angles

between vertical and horizontal blades as

shown as (figures 6-7-8).The openings are 0.5" x 0.5" at 0 & 45

angles and 1.8" x 0.5" at 30 angles.

oP«j ¬°kM ° nAjoP«j »\¯o�{ ºnA±½j ºBµ³`½nj

ºoMnB�

RBd¼�±U

JB� ° Bµ²oQ

»ioµB{ oP«j ¬°kM ° nAjoP«j »\¯o�{ ºnA±½j ºBµ³`½nj

nj �±ÇÇL�« ³½±´ÇÇU SíÇ®æ nj KwBÇ®« ºBÇǵºoÇMnBÇ� S´]

»eAoÇ� k{BM pB¼¯ nB�°n »§B¯BÇ� B½ k®¦M ºnA±½j ³� »½BÇ´¯Bñ«

/k¯A²k{

o�¯ jn±« ©� nBz� BM A±µ ¬B½o] ºjB½p nAk�« ³�»¯B«p "¿±æA

/j±{»« ²jB�TwA Bµ³`½nj �±¯ ­½A pA SwA

ºnBªí «o¢½ j ºBµºoMnB �ºAo MAn B´¯C Bµ³`½nj ­½A K§B]ºBª¯

/SwA ²jo� KwB®« RB®¼ÄqU °

n±�®« ³M ³`½nj �±Ç¯ ­Ç½A ºpA±ÇÇ« ºA±Çǵ ©Ç¼�®U ºBµ²oÇQ

nAoÇÇ� ºj±Çªî ° »Ç��A ºBÇÇ´Un±~M A±Çµ ¬B½o] nAk�« ¤oT®�

/k¯A³T�o£

³wnj ³� k®Tvµ »Ç«±Ç¼®¼«±Ç§C ³ñÇL{ ð½ Bǵ³Ç`½nj ­Ç½A

/k¯±{»« ³TiBw (»�o« ©hU ³¯B{) ðLz« Rn±æ ³M ²pAk¯A

SwA ²k{ ²jAj ¬BÇz¯ (8 Ç 7 Ç 6 ºBµ¥ñ{) nj ³� n±�¯Bªµ

30 , 0 ³Ç½°Ap ³w nj »Ç��A ºBµ²oQ ³� jnAj j±]° ¬Bñ«A ­½A

/k¯±{ SMBY ºj±ªî ºBµ²oQ ­¼M ³]nj 45 °

0.5" x 0.5" 45 ° 0 ºBÇǽA°p nj ³ñL{ fAn±ÇÇÇw jBíÇÇÇÇMA

/k{BM»« 1.8" x 0.5" 30 ³½°Ap °

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI 10

,

Page 12: Wall Type Registers

MATERIAL & FINISH

ORDERING CODE

High quality 1.25 mm thickness extruded

aluminium profile in matt aluminium

anodized finish for frame.The blades are aluminium grid with 0.8 mm

thickness. white polyester liquid or powder

coating and finish is also available or any

other specified color with raul code up on

requirement.

Shahrokhi egg wall registers (& grilles) with

following ordering code specified.

¡¯n ° jA±«

xnB�w k�

1.25 S«BÇÇh� ³M »Çzz� ¨±ÇǼ®¼«±Ç§C ¥¼�°oÇÇQ pA BµJBÇ�

KwB®« S¼�¼� BM ¨±¼®¼«±§C ²k{ q½AjBǯC y�°n BM oÇTª¼¦¼«

0.8 S«BÇh� ³M ¨±Ç¼®¼«±ÇǧC �n° pA Bµ²oÇÇQ /k¯±{»Ç« ³¼´U

ºqǼ«C ¡¯n ³� jnAj j±]° ¬BÇÇñ«A ­Ç½A /k®{BM»« oÇTª¼¦¼«

(ð¼UBTwA°oTñ§A)ºnj±Q B½ é½B« ¡¯n y{BQ x°n ³M »½B´¯

²nBÇǪ{ BM ºo¢Ç½j ¡¯n oµ B½ k¼�w oÇTwA»¦ÇQ pA ²jB�TwA BM

/j±{ ¨B\¯A pBǼ¯ ³M ³]±U BM }hz« ¤An

»ioµB{ oP«j ¬°kM ° nAjoP«j »\¯o�{ ºnA±½jºBµ³`½nj

/k¯±{»« }hz« o½p xnB�w k� BM

SH : Shahrokhi manufacture

WRE : Wall type register & grille

T : type : E0 : 0 Deg Egg

E30 : 30 Deg Egg

E45 : 45 Deg Egg

WXH : Width (inch) x height (inch)

»ioµB{ »Tí®æ ³¯BinB�

»ioµB{ ³¯BinB� : SH

oP«j ¬°kM ° nAjoP«j ºnA±½j ³`½nj : WRE

»\¯o�{ ³]nj o�æ ³½°Ap : E0 : ³`½nj �±¯ : T

(_®½A) çoî x (_®½A) �B�UnA : WXH

»\¯o�{ ³]nj »w ³½°Ap : E30

»\¯o�{ ³]nj [®Q ° ¥´a ³½°Ap : E45

SHAHROKHI MANUFACTURING CO.SHAHROKHI

SH.WRE.T-WXH

11

Page 13: Wall Type Registers

As shown as (figure 9) main frame including

the core of parallel V-bars and an auxilary

frame adjust for wall, partition or door

thickness.

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

LISTED SIZE-12.5

ALL DIMENSION IN mm.

32.0

32.0

ANGLE

(FIGURE 9)

DOOR LOUVERS (grilles)

APPLICATION

Shahrokhi door grilles used for transfer air

from one space to another space. These

door grilles can be fixed on the doors, walls

and partitions. They are usually used for

mass activity areas such as gymnasiums,

waterclosets and bath rooms, etc.

ºnjBQ ºBµ³`½nj

ºoMnB�

³M BÇ�� ð½ pA A±Çµ ¤BÇ�T¯A S´] »ioµBÇ{ ºnjBÇQ ºBµ³`½nj

º°n ¬A±ÇU»« An Bµ³Ç`½nj ­Ç½A /k¯±{»« ²jB�TwA o¢½j ºB��

­ÇǽA "¿±ÇÇªí« ,j±ªÇǯ K~ǯ Bǵ­Çz¼UnBÇQ B½ BµnA±Çǽj ,BÇǵnj

k®¯BÇ« kǯnAj »ÇÇ®¼¢®w ºA±Çµ ³� »Ç½BÇÇ´¯BÇñ« S´] Bµ³`½nj

jn±ÇÇ« ²oÇǼ� ° Bµ¨BÇǪe ,BµS§A±ÇÇU ,ð¼TwBÇÇ®ª½r ºBǵ­§BÇw

/k¯o¼£»« nAo� ²jBÇ�TwA

DECRIPTION

Shahrokhi door grilles constructed of a main

frame and auxilary frame.Which The main

frame fixed at air entrance side and the

auxilary frame adjust at air exhaust side.

RBd¼�±U

JBÇ� ð½ ° »¦æA JBÇ� ð½ pA »ioµBÇ{ ºnjBÇQ ºBµ³`½nj

° A±Çǵ j°n° Sªw nj »ÇǦæA K§BÇÇ� /k¯A²k{ ¥¼ñzU »ñª�

/k¯o¼£»« nAo� A±µ Z°oi Sªw nj »ñª� JB�

BIADES & FRAMES BµJB� ° Bµ²oQ JBÇÇ� ¬°nj SwA ²k{ ²jAj ¬Bz¯ (9 ¥ñ{) nj ³� n±�¯Bªµ

nAoÇÇ� o¢Çǽkñ½ RApA±ÇÇ« ³M V ¥ñ{ ³M ²oÇÇÇQ ºjAkíU »¦æA

nA±½j nj S «Bh� KwB®T« ³¦æBÇ� BM »ñª� JB� ° k¯A³T�o£

/j±{»« ©¼�®U »¦æA JB� pA ­z¼UnBQ B½

13

,

Page 14: Wall Type Registers

MATERIAL & FINISH

ORDERING CODE

Frames and blades are of high quality

1.5mm thickness extruded aluminium profile

in matt aluminium anodized finish.White polyester liquid or powder coating

finish is also available or any other specified

color with raul code up on requirement.

Shahrokhi door grilles with following

ordering code specified.

¡¯n ° jA±«

xnB�w k�

S«Bh� ³M »zz� ¨±Ç¼®¼«±ÇǧC ¥¼�°oÇÇQ pA Bµ²oÇQ ° BµJBÇ�

S¼�¼� BÇM ¨±¼®¼«±§C ²k{ qÇǽAjBǯC yÇ�°n BM oÇTª¼¦Ç¼« 1.5

/k¯±{»« ³¼´U KwBÇ®«

y{BQ x°n ³M »½B´¯ ºqǼ«C ¡¯n ³� jnAj j±]° ¬Bñ«A ­½A

pA ²jBÇ�TwA BÇM (ð¼UBÇÇTwA°oÇTñ§A ) ºnj±ÇÇQ B½ éÇǽBÇÇ« ¡¯n

}hz« ¤An ²nBǪ{ BM ºoÇ¢½j ¡¯n oµ Bǽ k¼�w oÇTwA»¦ÇQ

/j±{ ¨B\¯A pB¼¯ ³M ³]±U BM

}hz« o½p xnBÇ�w kÇ� BM »ÇioµBÇ{ ºnjBÇQ ºBǵ³Ç`½nj

/k¯jo£»«

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

SH : Shahrokhi manufactureLOU : LouverDG : Door grillesWXH : Width (inch) x height (inch)

»ioµB{ ³¯BinB� : SH

n°±§ : LOU

ºnjBQ ³`½nj : DG

(_®½A) çoî x (_®½A) �B�UnA : WXH

SH . LOU . DG - WXH

14

Page 15: Wall Type Registers

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M

NEGATIVE

ST.PRESS.

IN.W.G.

VELOCITY

F.P.M

225

450

675

900

1125

1350

1575

1800

275

550

825

1100

1375

1650

1925

2200

350

700

1050

1400

1750

2100

2450

2800

425

850

1275

1700

2125

2550

2975

3400

475

950

1425

1900

2375

2850

3325

3800

550

1125

1700

2275

2850

3425

4000

4575

102

205

307

409

511

614

716

818

98

195

293

390

488

585

683

780

101

203

304

406

507

609

710

812

101

202

304

405

506

607

708

810

101

202

303

404

505

606

707

809

98

199

301

403

505

607

709

811

0.008

0.029

0.067

0.096

0.146

0.198

0.260

0.321

0.008

0.026

0.062

0.089

0.134

0.183

0.240

0.298

0.008

0.028

0.066

0.095

0.144

0.195

0.256

0.317

0.008

0.028

0.066

0.940

0.143

0.194

0.255

0.316

0.008

0.028

0.066

0.094

0.143

0.194

0.254

0.315

0.008

0.027

0.065

0.093

0.143

0.194

0.255

0.317

25

50

75

100

125

150

175

200

25

75

125

175

225

275

325

375

25

75

125

175

225

275

325

375

50

100

150

200

250

300

350

400

50

125

200

275

350

425

500

575

50

125

200

275

350

425

500

575

12"x6"

AK=0.27

16"x6"

12"x8"

AK=0.39

18"x6"

AK=0.42

20"x6"

16"x8"

12"x10"

AK=0.52

24"x6"

18"x8"

12"x12"

AK=0.61

20"x8"

16"x10"

AK=0.69

93

185

278

370

463

556

648

741

64

192

321

449

577

705

833

962

60

179

298

417

536

655

774

893

96

192

288

385

481

577

673

769

82

205

328

451

574

697

820

943

72

181

290

399

507

616

725

833

0.007

0.024

0.057

0.084

0.122

0.168

0.219

0.275

0.001

0.025

0.071

0.116

0.179

0.253

0.330

0.407

0.001

0.023

0.064

0.100

0.158

0.223

0.294

0.366

0.007

0.025

0.060

0.088

0.131

0.179

0.234

0.291

0.005

0.029

0.073

0.116

0.177

0.248

0.322

0.396

0.003

0.023

0.061

0.092

0.144

0.200

0.265

0.330

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M

NEGATIVE

ST.PRESS.

IN.W.G.

VELOCITY

F.P.M

75

150

225

300

375

450

525

600

100

200

300

400

500

600

700

800

100

200

300

400

500

600

700

800

125

250

375

500

625

750

875

1000

175

325

475

625

775

925

1075

1225

200

400

600

800

1000

1200

1400

1600

89

179

268

357

446

536

625

714

106

213

319

426

532

638

745

851

92

183

275

367

459

550

642

734

98

195

293

391

488

586

684

781

107

198

290

381

473

564

655

747

101

202

303

404

505

606

707

808

0.006

0.023

0.053

0.080

0.114

0.158

0.205

0.253

0.009

0.032

0.070

0.104

0.156

0.213

0.277

0.341

0.006

0.024

0.056

0.083

0.120

0.165

0.215

0.270

0.008

0.026

0.062

0.090

0.134

0.183

0.240

0.299

0.009

0.027

0.061

0.087

0.127

0.172

0.223

0.278

0.008

0.028

0.066

0.094

0.143

0.194

0.254

0.315

SIZE

IN x IN

AK=sq.ft

FLOW

RATE

C.F.M

SH.LOU.DG

NEGATIVE

ST.PRESS.

IN.W.G.

VELOCITY

F.P.M

24"x8"

20"x10"

16"x12"

AK=0.84

36"x6"

18"x12"

16"x14"

AK=0.94

24"x10"

20"x12"

AK=1.09

36"x8"

20"x14"

24"x12"

AK=1.28

30"x12"

20"x18"

AK=1.64

30"x14"

36"x12"

AK=1.98

30"x16"

24"x20"

AK=2.20

36"x16"

30"x20"

AK=2.82

30"x24"

AK=3.45

36"x24"

AK=4.20

48"x20"

AK=4.70

48"x24"

AK=5.64

ENGINEERING PERFORMANCE DATA ºnjBQ ºBµ³`½nj RBLwBd« ¤°k]

15

Page 16: Wall Type Registers

SQUARE GRILLE DAMPERS

APPLICATION

Shahrokhi square grille dampers used for

adjust the air flow rate or close the grilles if

neccessery.The blades of these grille dampers are

construct in two type of parallel or opposite.The levers which used for adjust the parallel

blades are constructable in three types of

receprocating , switch and key.It is possible to contact these levers to an

electrical key or a remote control system

where high side walls or exposed ducts are

not available such as amphitheater, cinema,

etc.Either can be adjust the space optional

temperature by an electrical thermostat

which illustrate in control line.

x±£nB´a ºBµ³`½nj oP«j

ºoMnB�

©Ç¼�®U n±ÇÇ�®« ³M »ioµBÇÇ{ x±Ç£nBÇ´a ºBǵ³`½nj oP«j

¥«BÇ� éÇ�� S´] pBǼ¯ Rn±æ nj B½ A±Çµ ¬Bǽo] »ÇMj ¬Aq¼«

/k¯o¼£»« nAo� ²jB�TwA jn±« A±µ ¬B½o] »Mj

³TiBÇw 8 Ç 7 ° ºpA±ÇÇ« �±Ç¯ °j nj BÇǵoÇP«j ­Ç½A ºBǵ³�¼U

/k¯±{»«

k¯±{»« ²jB�TwA ºpA±« ºBµ³�¼U ©¼�®U S´] ³� »½B´«oµA

/k®{BM» « SiBw ¥MB � ºk¼¦ �° »`¼Ä±w »½±z� � ±¯ ³wnj

»ñ½oTñ§A k¼¦� ð½ ³M An B´«oµA ­½A ³� jnAj j±]° ¬Bñ«A ­½A

nA±Ç½j ð½ ³�»½BÇ´¯Bñ« nj n°j ²An pA ¤oÇT®� ©Tv¼w ð½ B½

»�«C ºBµ­§Bw k®¯B« toTwj ¥MB� o¼� nB�°n ¤B¯B� B½ k®¦M

/j±ª¯ ¥~T« jnAj j±]° ²o¼� ° Bª®¼w oUFU

²A±Çh§j ¬AqǼ« ³M An �¼d« ºBÇ«j nAkÇ�« ¬A±ÇU»Ç« ­¼®`ªµ

nAoÇ� ¬BÇ«o� oǼv« nj ³� »ñ½oTñ§A RBÇTw±«oU ð½ �w±U

/j±ª¯ ©¼�®U jo¼£»«

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI 16

,

,

Page 17: Wall Type Registers

DESCRIPTION

In receprocating type (figure 11) the lever is

in the middle of the damper frame which

removal at horizontal way.

RBd¼�±U

nAoÇÇ� oÇP«j JBÇ� �w° nj ¨oǵA (11 ¥ñ{) »½±z� �±¯ nj

/k{BM»« »��A ¬C S�oe ¤BÇ�T¯A �± ̄ ³� ³T�oÇ£

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

In opposite type (figure 10) removal by spin

a special screw.

ð½ ¬An°j �w±ÇÇU S�oe ¤BÇÇ�T¯A (10 ¥ñ{) 8 Ç 7 �±¯ nj

/jo¼£»« Rn±æ |±~h« _¼Q

17

ANGL E

S PE CI AL S CR E W

L I S T E D S I Z E -12.5

AL L DIME NS ION IN mm.

43

.5

8.0

(FIGURE 10)

L E V E R MOV E PAT H

48

.0

A L L DI ME NS ION IN mm.

L I S T E D S I Z E -12.5

10

.5

(FIGURE 11)

Page 18: Wall Type Registers

In key type (figure 13 ) the lever is over the

grille frame which removal at vertical way.

nAoÇÇÇ� ³`ǽnj JBÇÇ� º°n ¨oǵA (13 ¥ñ{) ºkǼ¦� �±¯ nj

/k{BM»« ºj±ªî ¬C S�oe ¤B�T¯A �±Ç¯ ³� ³T�oÇ£

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

(FIGURE 13)

AL L DIME NS ION IN mm.

L I S T E D S I Z E --12..5

In switch type (figure 12) the lever is in the

corner of the damper frame which removal at

spin way.

oÇP«j JBÇÇ� [Ç®� nj ¨oÇǵA (12 ¥ñ{) »ÇÇ`¼Ä±w �±Çǯ nj

/k{BM»« »¯An°j ¬C S�oe ¤BÇ�T¯A �±¯ ³� ³T�o£ nAoÇÇ�

18

L I S T E D S I Z E -12.5

AL L DIME NS I ON IN mm.

L E V E R R OT AT ION P AT H

10

.5

48

.0

(FIGURE 12)

Page 19: Wall Type Registers

ORDERING CODE

Shahrokhi square grille dampers with

following ordering code specified.

oǽp xnBÇ�w k� BM »ioµBÇ{ x±£nBÇ´a ºBǵ³`½nj oÇP«j

/k¯±{»« }hz«

xnB�w k�

»ioµB{ »Tí®æ ³¯BinB�

SH . GDS . T - WXH

SH : Shahrokhi manufacture

GDS : Square grille damper

T : RH : Handling control receprocating type

RR : Remote control receprocating type

SW : Switch type

KE : Key type

OP : Opposite type WXH : Width (inch) x Height (inch)

»ioµB{ ³¯BinB� : SH

x±£nB´a ³`½nj oP«j :GDS

»Twj ¤oT®� BM »½±z� : RH : �±¯ : T

n°j ²An pA ¤oT®� BM »½±z� : RR

»`¼Ä±w :SW

ºk¼¦� : KE

(_®½A) çoî x (_®½A) �B�UnA :WXH 8 ° 7 : OP

SHAHROKHI MANUFACTURING CO.SHAHROKHI

MATERIAL & FINISH

High quality 1.25 mm thickness extruded

aluminium profile in matt aluminium

anodized finish for key and opposite types.High quality 0.7 mm thickness aluminium

finish for receprocating and switch types.Either is possible to used 0.7 mm thicness

iron galvanized for receprocating, switch

and opposite types.White polyester liquid or powder coating and

finish is also available or any other specified

color with raul code up on request.

¡¯n ° jA±«

³M »ÇÇzz� ¨ ±ÇǼ®¼«±Ç§C ¥¼�°oÇÇQ pA ºA 8 Ç 7 ° ºkǼ¦� �±¯

BM ̈ ±ÇǼ®¼«±§C ²k{ qǽAjBǯC y�°n BM oTª¼¦¼« 1.25 S«Bh�

/k¯±{»« ³¼´U KwB®« S¼�¼�

S«BÇÇÇh� ³ÇM ¨±ÇǼ®¼«±Ç§C �n° pA »`Çıw ° »Ç½±z� �A±Ç¯A

/k¯±{»« ³¼´U BM oÇTª¼¦¼« 0.7

S«BÇÇÇh� ³M ²qÇǼ¯A±§BÇÇ£ ­ÇǵC �n° pA ¬A±ÇÇÇU»Ç« ­Ç¼®`ªµ

²jB�TwA 8 Ç 7 ° »`¼Ä±w ,»½±z� �A±¯A S´] oTª¼¦¼« 0.7

/j±{

y{BQ x°n ³M »½B´¯ ºq¼«C ¡¯n ³� jnAj j±]° ¬Bñ«A ­½A

oTwA»¦Q pA ²jB�TwA BM (ð¼UBTwA°oTñ§A)ºnj±Q B½ é½B« ¡¯n

³M ³]±ÇU BM }hz« ¤An ²nBǪ{ BM ºoÇÇ¢½j ¡¯n oµ B½ k¼�w

/j±{ ¨B\¯A SwA±inj

19

Page 20: Wall Type Registers

GRILLES FIXING DETAILS

A) The (figure 14) with selection chart shows

that the number of screw holes on any

selected grille.Note: For large size exceeds 18 inches an

additional beam used.

Bµ³`½nj K~¯ RB¼Äq]

fAn±ÇÇw jAkÇÇÇíU JBÇhT¯A ¤°kÇÇ] ²AoÇǪ´M (14 ¥ñ{) (�§A

JBÇÇÇhT¯A ºBÇÇÇǵ³`ǽnj ³Ç¼¦� K~ǯ S´Ç] ¨p¿ ºBǵ_ÇǼQ

/kµj»« ¬Bz¯ An ²k{

»îoÇ� o¼U ð½ pA _®½A 18 pA oT£nqM ºBµq½Bw S´] :³]±U

/j±{»« ²jB�TwA

»ioµB{ »Tí®æ ³¯BinB�SAHROKHI MANUFACTURING CO.SAHROKHI

B) The (figure 15) shows another grille fixing

method with use a special spring.

²jB�TwA BM An Bµ³`½nj K~ǯ pA ºo¢½j x°n(15 ¥ñ{) (J

/kµj»« ¬Bz¯ |±~h« o®� �±¯ ð½ pA

20

(FIGURE 14)

A

GH

B C D

E

F

4.5mm

95.0

S CR E W H OL E

12

.5

WIDT H

(i nch)L E NGH T

(i nch)

AL L DIME NS ION IN mm.

B

DC

AB E

F

G H

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

4 6 12 18 24 30 36 428 14 20 26 32 38 4410 16 22 28 34 40 46 48

(FIGURE 15)

SPECIAL SPRING

45

.0

27.0

ALL DIMENSION IN mm.

3.5 38 mm.

Page 21: Wall Type Registers

(o´{ ³«±e) »¯±ñv« ¤pB®«

(o´{ ¥iAj) »¯±ñv« ¤pB®«

ºjBÇÇ´®z¼Q ºAkæ ¬AqÇǼ«

¬BTwnBª¼M ºB´�BUA

B´¯BTwnBª¼M »æ±~i ° ¥ªî ºB´�BUA

¬BTwnBª¼M »«±ªî ºBµB��

ºnAjA u¯Ao�®� ºB´�BUA

»¯BªTiBw oUB�j

»æ±~i oT�j

»«±ªî oT�j

ºA³¯B½An oT�j

»�¼w±« º±½j±TwA

¬±½q½±¦U ° ±½jAn yhQ �BUA

BµoUBU

rBT¯±« ­§Bw

BµBv¼¦� ° k]Bv«

Bµ³¯BhMBT� ° tnAk«

B´µB¢z½B«pC

xo½mQ ºB´®§Bw

Bµ²p±« ° »«±ªî ºBµ³¯BhMBT�

SvQ oUB�j ° B´ñ¯BM

¬An±Twn ° »{pn° ºB´Q±¦�

Bµ³¯Bi ²±´�

B´µB¢{°o� »½¿BM RB�L�

³vL§A ²B¢{°o�

B´µB¢{°o� »¦æA RB�L�

Bµ²pB�« ,S�nB«oQ±w

»{pn° ºBµ­§Bw

¡®¼§±M ­§Bw

B®{ ºBµohTwA

³�±Mo« oUB�j ,Bµ³¯BinB�

ða±� RB\¯BinB�

ònqM RB\¯BinB�

¥Tµ ° B´¯BªTiBw ,B´¯BªUnBQC ºB´�BUA

ð¯BM ,}�n �BUA ,Bµ¥Tµ ºB´®§Bw

¥Tµ »«±ªî ºBµB��

Bµ¡®¼�nBQ ,Bµ³¯Bh½±zTin ,Bµ³¯BiqP{C

Residences (suburbia)

Residences (urban)

Music Auditoriums

Radio and Tv Broadcasting

Theaters

Hssembly Halls

Mosques, churches

Libraries and Schools

Laboratories

Recreation Halls

Public Libraries, Museums

Banks, Post Offices

Restaurants Night Clubs

Cafeterias

Dept Storesl (upper floors)

Clothing Stores

Dept Stores (main floors)

Supermarket, Retail stores

Sports Coliseums

Bowling Hlleys

Swimming pools

Factories, Supt offices

Light Manu facturing

Heavy Manu facturing

Offices Conference Rooms

Offices Executive

Office Private

Office General

Office Computer

Hospital Rooms

Hospital Operating Rooms, Wards

Hospital Public Spaces

Apartment, Buildings, Hotel Rooms

Hotels, Ballrooms, Bank Halls

Hotel Public Spaces

Kitchens, Laundries, Garage

Recommended Noise Criteria

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

ºoÇÇMnB� �w±T«

Akæ ¬Aq¼«APPLICATIONAVERAGE(NC)

(NC)

25

30

30

35

40

30

35

35

40

50

22

22

27

32

25

35

40

40

35

40

40

45

40

40

45

45

35

40

50

45

60

65

35

35

40

45

25

30

22

22

27

32

25

35

40

40

35

40

40

45

40

40

45

45

35

40

50

45

60

65

30

35

35

40

50

30

35

40

35

35

40

45

21

Page 22: Wall Type Registers

A±µ »]°oi ºjB´®z¼Q SîowRecommended delivery Velocities

ºoMnB�ºjB´®z¼Q Sîow

A±µ »]°oi

(m/s)

APPLICATION

Recommendeddelivery

Velocities(m/s)

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI

Quantity Imperial Unit Metric UnitForm Imperial

To MetricMultiply By:

Form MetricTo ImperialMultiply By:

kÇÇeA° ¥½kÇLU ¤°kÇ]Conversion Table

22

1.5 Ç 2.5

2.5 Ç 3.5

2.5 Ç 4.5

3.5 Ç 5.5

4.5 Ç 6

5 Ç 10

1.5 - 2.5

2.5 - 3.5

2.5 - 4.5

3.5 - 5.5

4.5 - 6

5 - 10

yhQ ºBµ±½j±TwA

�L� ° Akæ ºBµ±½j±TwA

ð½p±« ºBµ­§Bw ,Rov®� ºBµ­§Bw

tnj ºB´wÀ� ° Bµ³¯BhMBT�

ºBµ­§Bw ,¥Tµ ºBÇ´�BUA ,»¯±ñv« ºBµ³¯Bi ,B´¯BªUnBQC

k]Bv« ° B´¯BTwnBª¼M ,»æ±~i oUB�j ,oUBÃU

ºn±i Am� ºB´®§Bw ,B´¦Tµ ,B´¯An±Twn ,ònqM oUB�j

»«±ªî ºB´®§Bw °

Bµ³¯Bi²±´� ,oU±¼P«B� ºB´�BUA ,Bµ°oµAn

B´µB¢{°o� °

BµrAnB£ ,B´µB£nB� ,�w±T« RB\¯BiB�

x°o� oUB�j °

Broadcasting studios, Sound and

recording studios.

Concert halls, Auditoriums, Library,

Classrooms

Large offices, Restaurants, Hotel

Dining rooms, Public buildings

Corridors, Computer-rooms, Cafeterias

Department stores

Average factories, Workshops, Garages

Warehouses

Apartments, Residences, Hotel rooms

Theatres, Private offices, Hospitals, Mosques

square foot

square inch

square metre

square milimetre

0.0929

645.16

10.764

0.00155

(m )

(mm )

2

2

3

3

Area

Density

Length

Pressure

Temperature

Velocity

Volume

(flow)

inch

foot

foot

yard

milimetre

milimetre

metre

metre

25.4

304.8

0.3048

0.9144

0.0394

0.00328

3.2808

1.0938

(mm)

(mm)

(m)

(m)

inch of water column

foot of water column

inch of mercury column

ounces per square inch

pounds per square inch

Kilopascal

Kilopascal

Kilopascal

Kilopascal

Kilopascal

0.2486

2.9837

3.3741

0.4309

6.8948

4.0219

0.3252

0.2964

2.3206

0.145

(kPa)

(kPa)

(kPa)

(kPa)

(kPa)

fahrenheit celcius 5/9 ( F-32) (9/5 C)+32( C)

feet per second

feet per minute

miles per hour

metres per second

metres per second

metres per second

0.3048

0.00508

0.44704

3.2808

196.85

2.2369

(m/s)

(m/s)

(m/s)

cubic feet per minute

cubic feet per minute

cubic feet per hour

galons per minute

galons per minute

litrs per second

cubic metres per second

milliters per second

litres per second

litres per second

0.4719

0.0004719

7.8658

0.6309

0.7577

2.119

2119.0

0.127133

15.850

13.198

(L/s)

(m /s)

(ml/s)

(L/s)

(L/s)

(cfm)

(cfm)

(cfh)

(U.S.)

(imperial)

(fps)

(fpm)

(mph)

pouds per cubic foot kilograms per cubic metre 16.018 0.0624(kg/m )

Page 23: Wall Type Registers

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI 23

:ºoµB� SLv¯

/k{BM»« ³`½nj ³ñL{ �B�UnA ³M çoî SLv¯

:�±�w

ºB´ÇÇT¯A »Ç®¼ÄBÇQ ³ÇL§ ° »Ç®¼ÄBÇQ ³ÇÇL§ ­Ç¼M ºj±ÇÇªî ³ÇǦæB�

/k{BM»« R±� Kve oM A±µ ºBµ³½¿ ³MBUoQ o¼v«

RnAoe ³]nj �ÀTiA ° Sîow ,³MBUoQ ¤±� ³M �±�w nAk�«

/ jnAj »¢TvM �B�A ºA±µ ° S�n ºA±µ ­¼M

: ð¼UBTwA nBz� (P )

}Çhz« ©\e ð½ ºAoÇM ³� JC _®½A Kve oM SLX« nBz�

²B£±¦ÇÇ£ nj »æ±ÇÇ~h« ²k{ »ÇeAo� ¨pA±§ ¬°kM B½ ° BM A±µ

/jnAj j±]° ³`½nj

S

: »Tîow nBz� (P )

©\e ðǽ ºAoM ³� »ÇTîow ¤jBÇí« JC _®½A Kve oM nBz�

/jnAj j±]° ³`½nj ð½ ²B£±¦£ nj A±µ }hz«

v

»®� RBeÀ�æA

:»]°oi é��« c�w (A )

nj A±µºBµ ³½¿ n±Lî S´] ³� k{BM»« ³`½nj ð½ SeBv«

³í]Ao«»]°oi Sîow ³M) V »]°oi Sîow ³�ºA ³��¯

jn±Ç« , k{BÇM ²k{ ºo¼£²pAk¯A »LwB®« ²B¢Twj �w±U (j±{

/jo¼£»« nAo� ²jB�TwA

CFM »Tv½BÇM ºoÇǼ£²pk¯A ²B¢Twj �±¯ ° ºo¼£²pAk¯A ³��¯

/k½Bª¯ }hz« An �¼�j ²k{ ³LwBd«

k

k

k kCFM=A x V

The area of grille utilized by the air stream at

the point of the outlet velocity, V (See

outlet velocity) as measured with an

appropriate meter.CFM=A x V

The point of measurement and type of

metre must be defined to accurately

determine CFM.

k

k

k k

Outlet Area (A ):

TERINOLOGY

Aspect Ratio:

The ratio of width to height of the grille core.

Drop:

The vertical distance in feet between the

lower edge of a grille and the lower edge of

the air stream at the end of its throw.Drop is

affected by the lenght of throw the velocity

and the temperature differential between the

supply and room air.

The compressive pressure in inches of H O

that exists in the grille collar area at a given

air volume with or without specific

designated accessories.

2

sStatic Pressure (P ):

The pressure in inches of H O equated to a

velocity that exists for a given air volume in

the grille collar area.

V

2

Velocity Pressure (P ):

Page 24: Wall Type Registers

»ioµB{ »Tí®æ ³¯BinB�SHAHROKHI MANUFACTURING CO.SHAHROKHI 24

The maximum total width in feet of the air

pattern at the point of terminal velocity.

Air Spread :

The distance in feet from a grille or

designated location to a point where the

motion of the air stream is reduced to a

given terminal velocity (V )T

Throw (T) :

The measured velocity at a stated point with

a specified meter. The rated outlet velocity is

typically an average of several prescribed

velocity measurements.CFM = A x V (see outlet Area)

K

k k

Outlet Velocity (V ):

The velocity in FMP of the air stream at the

end of the throw (T) from the grille or a

designated point.

TTerminal Velocity (V ):

A grille sound rating in pressure level at a

given condition of operation , based on

established criteria and specific room

acoustic absorption value. Catalogs NC

ratings are based on sound power level (LW)

minus and 18db room attenuation all actave

bands.

Noise Criteria (NC) :

:A°µ yhQ

ºA ³��¯ nj R±� KvÇe oM A±µºBµ ³Ç½¿»¦� çoÇî oX�Ake

/k{BM»« ²k{ºo¼£ ²pAk¯A»½B´¯ Sîow ³�

: Akæ ¬Aq¼« (NC)

nj �½Ao{ ð½ SdU nBz� c�w Kve oM ³`½nj ºAkæ fo¯

nAk�« ° ºjAjnAoÇÇ� ¬AqÇǼ« ³M ³� k{BM»« »~hz« nB� ¤BÇe

/jnAj»¢TvM �BUA |±~h« ð¼Tw±�A Jm]

18 ºB´®« (LW) Akæ Rnk� c�w ³M Akæ ¬Aq¼« fo¯ o½jB�«

/jnAj»¢TvM °BT�A ºBµk¯BM ¨BªU nj ¬C �B�A nj yµB� ¥M»wj

: »½B´¯ Sîow (V )

ð½ B½ ³`½nj pA JBUoQ o¼v« ºB´T¯A nj A±µºBµ ³½¿ Sîow

/k{BM»« ³�¼�j nj R±� Kve oM »~h{« ³��¯

T

: ³MBUoQ (T)

KÇve oM ³��¯ ðǽ pA»«±¦í« ¥dÇÇ« B½ ³`ǽnj ð½ ³¦ÇæB�

Sîow ³M ¬k¼wn BU A±µºBµ ³½¿ S�oe ³� k{BM»« R±�

/k®�»« Ak¼Q yµB� (V ) »~hz«»½B´¯T

: »]°oi Sîow (V )

²B¢ÇTwj ð½ �Çw±U ³��¯ ð½ nj ²k{ºo¼£ ²pAkǯA Sîow

/k{BM»« |±~h«

ºjAkÇíU �w°ÇÇT« ,¤°AkÇT« Rn±~M »ÇÇ]°oÇi Sîow foÇǯ

/k{BM»« ²k{ºo¼£ ²p Ak¯A ­¼í«Sîow

(j±{ ³í]Ao«»]°oi ³��« c�w ³M)k k

k

CFM = A x V

: ¥�nBz� (P )

³� (P ) »ÇTîoÇw nBÇÇzÇ� ° (P ) ðǼUBTwA nBz� �±ª\«

/jnAj j±]° ³`½nj ²B£±¦£ nj }hz« ºA±µ ©\e ð½ ºAoM

T

SVThe sum of the static pressure (P ) and the

velocity pressure (P ) that exists in the grille

collar for a given air volume.

T

S

V

Total Pressure (P ):

Page 25: Wall Type Registers

MANUFACTURING CO.(Establishment 1950)

SHAHROKHI

1890 ²nBª{ Ç tnBP¯Ao´U ²AnnB´a pA kíM Ç k¯°B«j ¬BMB¼i Ç ¬Ao´U

16575 Ç 115 : »TvQ �°k®æ 16548 : »TvQ k�

771952 : u�B� 772388 Ç 773388 : ­�¦U

www.shahrokhimfg- co.com Email : info@shahrokhimfg- co.com

No. 1890, Damavand St, After Tehranpars Cross,

Tehran, IRAN. Post Code : 16548

P.O.Box : 16575-115