2
EXCLUSIVE MAIN CONTROLS FOR MODELS 60H, 90H AND 190H ® WALL CONTROLS INTERMITTENT MAX MIN VC0080 L-T RECIRCULATION MAX MIN VC0081 S-T VC0039 MIN. MAX. OFF M E U I D L E S S H U M ID O -30°C -22°F EXCLUSIVE MAIN CONTROLS FOR GOLD AND HIGH EFFICIENCY SERIES UNITS CONDENSA TI0N CONTROL A A AIR SUPPL Y CONTROL L L MIN. MAX. OFF AIR EXCHANGE CH HA -20°C -4°F ° 41° F C O N E S U M M E R VC0035 -20°C -4°F - C 41° F CONDENSA TI0N CONTROL A A AIR SUPPL Y CONTROL L L CONDENSA TION CONTROL MAXIMUM SPEED AIR EXCHANGE IN PROGRESS MIN. MAX. CONTINUOUS INTERMITTENT 20 MIN . ON 40 MIN. OF C M Z O E S U M M E R VC0036 BASIC PART # 40210 ELECTRO PART # 40220 PULL PULL LITE-TOUCH BRONZE P ART # 40270 The light indicator color of this new wall control shows clearly in which operating mode the unit is. This push-button control has three functions: •Intermittent (low speed exchange during 20 minutes, then stops during 40 minutes) • Min (low speed) • Max (high speed) BRONZE P ART # 40250 This control adjust the air supply speed using the sliding button: OFF, MIN (low speed) and MAX (high speed). Also, the maximum indoor humidity level for your house is selected by the knob. SIMPLE-TOUCH BRONZE P ART # 40290 EXCLUSIVELY DESIGNED FOR 60H UNITS. The light indicator color of this new wall control shows clearly in which operating mode the unit is. This push-button control has three functions: • Recirculation (stops exchanging with the outside and recirculates inside air at high speed) • Min (low speed) • Max (high speed) OPERATION MODES INTERMITTENT EXCHANGE (NOT AVAILABLE ON BASIC) This mode provides 20 minutes of air exchange per hour. If the dehumidistat or remote switch is activated, the ventilation rate will go to high speed until the conditions are satisfied. This mode is ideal when the home is unoccupied. High speed ventilation will be activated by the dehumidistat or remote switch. LOW SPEED CONTINUOUS EXCHANGE Ideal for normal occupancy, this mode provides a continuous low rate of ventilation. High speed ventilation will be activated by the dehumidistat or by a remote switch. HIGH SPEED CONTINUOUS EXCHANGE When occupancy increases, high speed ventilation will help to quickly reduce pollutants. HUMIDITY CONTROL MAXIMUM SPEED (NOT AVAILABLE ON BASIC) This light goes ON when the humidity control shifts the unit to high speed, in order to eliminate the excess humidity. When this light is ON, the setting of the AIR SUPPLY CONTROL can still be changed, but these changes will only take place when the CONDENSATION CONTROL MAXIMUM SPEED goes OFF. 20 MIN. ON 40 MIN. OFF VQ0001 MIN. VQ0002 MAX. VQ0003 VQ0006 FEATURES DEHUMIDISTAT By adjusting the interior relative humidity according to outside temperature, the homeowner can control condensation on windows. EXCHANGE INDICATOR This indicates that stale air is being exhausted and replaced by fresh air. MAINTENANCE INDICATOR (NOT AVAILABLE ON BASIC) After 3 months of ventilation the INTERMITTENT EXCHANGE light (when flashing) will show the need to clean the filters and check for other routine maintenance. Once service is performed, the light is reprogrammed. -20C -4F -5C 23F 5C 41F C O M FO R TZ ONE S U M M E R VQ0004 AIR EXCHANGE VQ0005 20 MIN. ON 40 MIN OFF VQ0001 Those 2 controls are compatible with the electronic board of both Gold and High Efficiency Series, allowing to change from a Basic wall control to an Electro. The Electro control remembers which control strategy was in use even after a power failure. Even the date of the last service is maintained as a convenience to the homeowner.

Transcript of WALL CONTROLS - Eden Energy

EXCLUSIVE MAIN CONTROLS FOR MODELS 60H, 90H AND 190H

®

WALL CONTROLS

INTERMITTENT

MAXMIN

VC0080

®

L-T

RECIRCULATION

MAXMIN

VC0081

®

S-T

VC0039

MIN.

MAX.OFF

ME U ID

LESS HUMID

O

-30°C-22°F

EXCLUSIVE MAIN CONTROLS FOR GOLD AND HIGH EFFICIENCY SERIES UNITS

CONDENSATI0N CONTROLAA

AIR SUPPLY CONTROLLL

MIN.

MAX.

OFF

AIRAIREXCHANGECHHA

-20°C-4°F °

41°F

CO N E

SUMM

ER

VC0035

-20°C-4°F

-C

41°F

CONDENSATI0N CONTROLAA

AIR SUPPLY CONTROLLL

CONDENSATION CONTROLMAXIMUM SPEED

AIR EXCHANGE IN PROGRESS

MIN. MAX.

CONTINUOUSCONTINUOUS INTERMITTENTTINTERMITTENT

20 MINM .NNONON

40 MIN.MOFFOF

C M Z O E

SUMM

ER

VC0036

BASIC

PART # 40210ELECTRO

PART # 40220

PU

LL

PU

LL

LITE-TOUCH BRONZE

PART # 40270The light indicator color of this new wall control showsclearly in which operating mode the unit is.This push-button control has three functions:

•Intermittent (low speed exchange during 20 minutes, then stops during 40 minutes)

•Min (low speed)•Max (high speed)

BRONZE

PART # 40250This control adjust the air supply speed using the sliding button: OFF, MIN (low speed) and MAX (highspeed). Also, the maximum indoor humidity level for yourhouse is selected by the knob.

SIMPLE-TOUCH BRONZE

PART # 40290EXCLUSIVELY DESIGNED FOR 60H UNITS.The light indicator color of this new wall control showsclearly in which operating mode the unit is.This push-button control has three functions:

•Recirculation (stops exchanging with the outsideand recirculates inside air at high speed)

•Min (low speed)•Max (high speed)

OPERATION MODES

INTERMITTENT EXCHANGE (NOT AVAILABLE ON BASIC)This mode provides 20 minutes of air exchange per hour. If the dehumidistat orremote switch is activated, the ventilation rate will go to high speed until the conditionsare satisfied. This mode is ideal when the home is unoccupied. High speed ventilationwill be activated by the dehumidistat or remote switch.

LOW SPEED CONTINUOUS EXCHANGEIdeal for normal occupancy, this mode provides a continuous low rate of ventilation.High speed ventilation will be activated by the dehumidistat or by a remote switch.

HIGH SPEED CONTINUOUS EXCHANGEWhen occupancy increases, high speed ventilation will help to quickly reduce pollutants.

HUMIDITY CONTROL MAXIMUM SPEED (NOT AVAILABLE ON BASIC)

This light goes ON when the humidity control shifts the unit to high speed, in order toeliminate the excess humidity. When this light is ON, the setting of the AIR SUPPLYCONTROL can still be changed, but these changes will only take place when the CONDENSATION CONTROL MAXIMUM SPEED goes OFF.

20 MIN.ON

40 MIN.OFF

VQ0001

MIN.VQ0002

MAX.VQ0003

VQ0006

FEATURES

DEHUMIDISTATBy adjusting the interior relative humidity according to outside temperature, thehomeowner can control condensation on windows.

EXCHANGE INDICATORThis indicates that stale air is being exhausted and replaced by fresh air.

MAINTENANCE INDICATOR (NOT AVAILABLE ON BASIC)After 3 months of ventilation the INTERMITTENT EXCHANGE light (when flashing)will show the need to clean the filters and check for other routine maintenance. Onceservice is performed, the light is reprogrammed.

-20C-4F

-5C23F

5C41F

COMFORT ZONE

SUMM

ER

VQ0004

AIR EXCHANGEVQ0005

20 MIN.ON

40 MINOFF

VQ0001

Those 2 controls are compatible with the electronic board of both Gold and HighEfficiency Series, allowing to change from a Basic wall control to an Electro.The Electro control remembers which control strategy was in use even after a powerfailure. Even the date of the last service is maintained as a convenience to the homeowner.

20-MINUTE LIGHTED

PUSH BUTTON

PART # 1806110This timer allows the unit to provide 20minutes of high speed ventilation at thepush of a button, to exhaust rapidlyindoor stale air. Lighted when activated,up to five of them can be installed (eg: inbathrooms, kitchen, laundry room, etc.).(Available only for 60H, 90H and190H units).

60-MINUTE CRANK TIMER

PART # 00910This timer allows from 10 to 60 minutes ofhigh speed operation, to exhaust rapidlyindoor stale air. Can be installedd inbathrooms, kitchen or laundry room.

HUMIDITY CONTROL

PART # 200694The knob allows to adjust the maximumdesired indoor humidity level during fall,winter and spring. This control is graduatedin relative humidity percentage degrees.When a higher humidity level is detected,the unit turn on high speed until the situation is corrected.

AUXILIARY CONTROLS

VENTILATION

®

VC0040

OFF

10

20

30

40

50

60

TURNPAST

20

VC0017

FORT Z

F

RELL HU

70%

60%

50%

30%

25%

20%

HUMIDITYCONTROL

DURING FALL, WINTERFFAND SPRING, SET THE DIAL ACCORDING TO

THE DESIRED MAXIMUMINDOOR HUMIDITY LEVEL.

DURING SUMMER SETTHE DIAL TO THEOFF POSITION.

VC0038

20/40/60-MINUTE

PUSH BUTTON

PART # 03701This timer allows to turn on the unit onhigh speed during 20, 40 or 60 minutes,to exhaustl rapidly indoor stale air. Within2 seconds, press once for 20 minutes,twice for 40 minutes or three times for a60-minute activation. Press another timeto desactivate. (Available for Gold andHigh Efficiency Series units only).

WARRANTY

Subject to any applicable consumer protection legislation, the company warrants that all main and/orauxiliary vänEE controls are covered by the same warranty as the vänEE unit they are connected, providedvänEE control is under normal use and installation is in accordance with the provided installation instructions.

INSTALLATION

The vänEE controls are very easy to install! Using a 4-conductor telephone wire, perform the connection directly on the electronic board terminals. The following diagramsshow the terminal strips in the control box.

VC0041

20 min.

40 min.

60 min.

®

www.vanee-ventilation.ca 06/05 PRODUCT SHEET # 90221

®

550 Lemire blvd., Drummondville, QC, Canada J2C 7W9 - Tel.: 1 800 567-3855 Fax: 1 800 567-1715

60H UNITS - MAIN CONTROLS

60H UNITS - AUXILIARY CONTROLS

NO C NC I OC OL Y R G B

BGOC

MAIN WALL CONTROLLITE-TOUCH BRONZE

andSIMPLE TOUCH BRONZE

REAR VIEW

G BY

VE0101A

NO C NC I OC OL Y R G B

VE0103

COM FORT ZONE

OFF

% RELATIVEHUMIDITY

70%

60%

50%40%

30%

25%

20%

HUMIDITYCONTROL

MIN.

MAX.OFF

MORE HUMID

LESS HUMID

CO

MF

OR

TZ

ON

E

-30°C-22°F

-20°C-4°F

-5°C23°F

5°C+41°F+

NO C NC I OC OL Y R G B

20-MINUTED LIGHTED PUSH BUTTON (5 MAXIMUM)

60-MINUTECRANK TIMER

HUMIDITY CONTROL

VE0105A

CO M FORT Z ON E

OFF

% RELATIVE HUMIDITY

70%

60%

50%40%

30%

25%

20%

HUMIDITYCONTROL

DURING FALL, WINTER AND SPRING, SET THE DIAL ACCORDING TO

THE DESIRED MAXIMUM INDOOR HUMIDITY LEVEL.

DURING SUMMER SET THE DIAL TO THE OFF POSITION.

90H AND 190H UNITS - MAIN AND AUXILIARY CONTROLS

VE0008

CONNECTION FOR

BRONZE MAIN CONTROL

CONNECTION FOR AUXILIARY CONTROLS

(OL AND OC FOR TIMER AND HUMIDITY

CONTROL, OL, OC AND I FOR LIGHTED

PUSH BUTTON)

BG

OLOC

I

VE0116

CONNECTION FOR LITE-TOUCH BRONZE

MAIN CONTROL

BG

OLOC

I

CONNECTION FOR AUXILIARY CONTROLS

(OL AND OC FOR TIMER AND HUMIDITY

CONTROL, OL, OC AND I FOR LIGHTED

PUSH BUTTON)

VE0007

CONNECTION FOR BASIC

OR ELECTRO MAIN CONTROL

CONNECTION FOR FURNACE

INTERLOCK RELAY

CONNECTION FOR AUXILIARY CON-TROLS (OL AND OC FOR TIMER

AND HUMIDITY CONTROL, OL, OCAND I FOR PUSH BUTTON)

BGRYOLOC

IFF

GOLD AND HIGH EFFICIENCY SERIES UNITS - MAIN AND AUXILIARY CONTROLS

FURNACE INTERLOCK RELAY

(FOR GOLD AND HIGH EFFICIENCY SERIES UNITS ONLY)The furnace can be interlocked so it will run simultaneously with the ventilation system to ensure properdistribution of fresh air throughout the house.