Page 1: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALDINSTALLATION EN

Page 2: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

4 4

Installation option 1; fixing THROUGH ceiling. Installation option 2; fixing TO ceiling.

Page 3: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

Points for special attention when installing the Wald• Installation option 1, fixing with threaded ends and counter plate is recommended. This provides the Wald with better side-collision protection. • If the ceiling height exeeds 2750mm, the Wald can only be suspended according to option 1, with the counter plate and threaded ends. • The Wald can only be connected to an insulated double-walled flue. • This stove appliance must be fitted to a ceiling that can easily support the load. • The weight of the double-walled flue must not be supported by the connection to the Wald.

Poujoulat Efficience • Can be connected to the Poujoulat Efficience to draw in fresh air through the flue. A special connector is required for this and can be supplied with the stove if requested. Art. nr. ENA15SP49. • The Poujoulat Efficience duct may be up to 6 metres in length.

Page 4: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

Installation option 1; fixing THROUGH ceiling.

Fixing with threaded ends and counter plate is recommended. This provides the Wald with better side-collision protection.

1. Position the counter plate on the ceiling.

3. Secure the ceiling plate to the threaded ends with 4x coupling nuts and M8x20 countersunkhead bolts.

2. Fix the threaded ends tot the counter plate.

4. Fix both plates with the nuts on the counterplate.

Page 5: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

Installation option 2; fixing TO ceiling.

.

1. Mark out het ceiling plateUse the cardboard template. Face the flatbit to the rear. Mark the 12 holes on the ceiling.

2. Drill holesDrill 6 holes distributed over the ceiling plate. Pilot drill with Ø6, finish with Ø14.Should a position be difficult to drill through, use one of the other marked positions.

3. Securing ceiling plateUse 6 anchors and M8x55 countersunk head bolts. The bolts must not protrude form the ceiling plate.

Please note: the construction of the ceiling must be appropriate for this method of attachment.

Page 6: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

Installation option 1&2

4. Determine the length of the double-walled inner flueUse a telescopic, double-walled flue that can be adjusted to fit- L= Length telescopic double-walled flue, excluding the connector- X = Length mantel pipe Wald- Y = Length of double-walled flue that protrudes from the ceiling- L = X - Y - 65mm

5a. Double-walled connectorInstall the connector for the double-walled flue

5b. Poujoulat connector (only for use with the Poujoulat Efficience)Install the connector for the Poujoulat Efficience flue

6. Perparing the mantel pipeLay the mantel pipe horizontally. Insert the double-walled flue adjusted to length into the mantel pipe. Bring the mantel pipe with the double-walled flue inot an upright position.

Page 7: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

7. Installing the double-walled flueLift the double-walled flue out of the mantel pipe and attach this to the section that is protruding from the ceiling.

8. Attaching the mantel pipePut the mantel pipe on the lift. Use the lift for attaching the mantel pipe to the ceiling plate. Secure the mantel pipe with 6x M8x16 countersunk head bolts.

Page 8: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

9. Levelling the mantel pipeCheck to see if the mantel pipe is haning plumb. Adjust for plumb if necessary using the 3x socket-head screws. Loosen the 6x M8x16 a little befor you do this. Afterwards re-tighten the 6x M8x16.

10. Transport the stove with a hand truckUse protection between the stove and the hand truck. Ensure that the wooden transport plate is snug against the base. Seat the stove with the side against the hand truck. Never position the stove with the front against the hand truck; this can damage the glass. Never position the stove with the back against the hand truck; this can damage the air valve.

11. Swivel lock If 2x60° rotatable, install the swivel lock.

Page 9: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

12. Position stove on the lift

13. Attaching the connector Elevate the lift and first attach the double-walled flue to the swivelling ring. Please note: the weight of the double-walled flue must not be supported by the Wald’s swivelling connector.

14. Securing the stoveElevate the lift more and secure the stove. Use the 6x M8 bolts supplied.

Page 10: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

15. Transport plateRemove the M6 bolt and with this the wooden transport plate.

16. Air supply cover plate (only for use with the Poujoulat Efficience) Secure the air supply cover plate underneath with 3x M6. Please note: only install the cover plate in conjunction with the Poujoulat Efficience.

17. FootSecure the foot with M6 threaded end and nut.

Page 11: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

18. InspectionCheck if the stove is fixed securely to the ceiling. Check if the aeration pipes are properly connected. Check that the heat shield is properly seated underneath.

Page 12: WALD - Leenders Haardkachels€¦ · Poujoulat connector (only for use with the Poujoulat Efficience) Install the connector for the Poujoulat Efficience flue 6. Perparing the mantel

WALD LEENDERS

2019.49.002.I.EN

General instructions and regulations

InstallationFor the validity of the guarantee the Wald must be installed by a professional fitter employed by a recognised Leenders dealer. See leenders.nl for a current list of addresses of approved dealers or contact the factory.

The stove is susceptible to scratching: caution is recommended. Stoke the stove following the instructions in the manual.

Use• All local regulations, including those reffering to national and European standards must be observed when fitting the appliance. • ensure ample ventilation/air supply in the room where the stove is installed. Air extraction, such as an extractor hood, can cause problems in the form of flue gases escaping from the stove into the room. • The appliance is suitable for use with a chimney ventilator. • The appliance is suitable for sharing a flue. • This appliance must be fitted to a ceiling that can easily support the load. • Ensure there is ample access for cleaning the appliance, the flue gas connection and the chimney.

Safety regulations• For matters of general safety, we refer you to the VCA guidelines. • Glass is very fragile and broken glass is very sharp. Take sufficient safety precautions. • Please note that after installation no combustible and/or materials with a danger of exploding should be placed in the stove, like spray cans, packaging materials and such like.

Safe distance for Wald from combustible materials • Rear wall: 15 cm. • Side wall: 80 cm. • Front: 110 cm.

Wald specifications• Nominal capacity = 7,9 kWh• Heat emisson capacity = 7,9 kWh• Flue gas mass flow = 7.5 g/s • Mass appliance = 145kg• Minimum chimney draught = 0.12mbar• Flue gas temperature directly above the stove = 209 °C• Energy Efficiency 82,9%, class A+, 111,4 index