W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves...

9
T E S 0036 MANAGEMENT SERVICE W 0 / TRD 100 YYH FIRE HYDRANTS

Transcript of W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves...

Page 1: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

T ES

0036

MANAGEMENT SERVICE

W 0 / TRD 100

YYH

FIRE HYDRANTS

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

2016 - 11

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Page 2: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Page 3: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

YAKACIK Fire Hydrants

Field of Application

Main Components

Working Principle

AutomaticDischarging

Immediate Intervention No Shock EffectNo PumpingAction

Long Life

Design and modification rights are reserved

Fire hydrants are used to extinguish fire at buildings, factories, industrial plants etc.

YAKACIK VALF Fire Hydrants are compatible with TSE 2821/1. Main components are cast iron body, operating equipment (valve), stem whichtransmits motion to valve, automatic discharge equipment and hose assembly parts.

When the operating nut is turned in opening direction by a special hydrant wrench, the stem moves down. Disc is seperated from the seat and waterflow starts. When operating nut is turned in closing direction, the disc contacts with the seat and halts the water flow. In the closed position, the waterpressure exerts a force on disc in closing direction which enhances leaktightness.

YAKACIK VALF firehydrants provide waterto fire fighters in a veryshort time. They enableimmediate interventionto minimize human lifeand property loss.

The c ross sec t i onof the YAKACIK VALFfire hydrants is uniformwhich prevents waterturbulence. Shock effectis eliminated and the firefighter can easily handlethe hose.

The automatic dischargeequipment dischargesthe residual water inthe body to protect thehydrant against freezing.

Since water pressureexerts a force in theclosing direction, It iseasy to shut off the waterflow.

When the hydrant is inopen position, wing formof the plug preventsvibration. Having negligiblevibration provides longservice life.

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Page 4: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

Operating Nut

SpindleLower and Upper Cover

Guided Nut

Stem

Bellows Body

Elbow

Lower Body

Seat Rubber Gasket

Hydrant Key

Spindle

Upper Body

Middle Body

Seat

Plug

Union andConnection Cap

Union GasketRubber Gasket

Rubber Gasket

YAKACIK Fire Hydrants

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Design and modification rights are reserved

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Page 5: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

DN 80-100-150Tip: YYHShort-Middle-Long

Part NameP.No

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

Lower Body

Plug

Plug Nut

Plug Gasket

Drain Valve Spring

Drain Valve Nipple

Drain Valve Seat

Drain Valve Gasket

Drain Valve Ball

Drain Valve Discharging Hose

Stem 1"

Stem Pin

Guided Nut

Spindle

Setscrew M8x40

Bolt

Bolt

O- ingR

O- ingR

O- ingR

O- ingR

O- ingR

Connection Cap

Union

Union Gasket

Union Chain

Elbow

Union Chain Fixing Ring

Material Type

Size

Pressure Class

Dimensions

Assembly

Unions

Flanged Elbow

Hydrant Key

Order Code

Cast Iron

GJL 250

GJL 250

GJL 250

GJL 250

GJL 250

Ck 22 + 1.4408*

0.7040*

0.7040*

St-42 + al.G

St-42 + al.G

Nitrile Rubber

Ms-58

Ms-58

1.4310

Nitrile Rubber

Glass

Plastic

St-42

Ms-58

Ms-58

1.4021

8.8+Gal.

8.8+Gal.

8.8+Gal.

Nitrile Rubber

Nitrile Rubber

Nitrile Rubber

Nitrile Rubber

Nitrile Rubber

Al*

Al*

Nitrile Rubber

St-37

GJL 250

St-37

Cast Iron

DN 80-1 00

PN16

TS EN 14384

Flanged according to

DIN EN 1092-2 PN 16

According to TS 12258

According to DIN 28538

According to TS 37398

YFH.2F. __.__

* Upon request, 1.4408 may be produced

OutletsValve

TypeDN

Short

Middle

LongYYH 80

YYH 100Short

Middle

Long

Nom.Dia.

80

100

D

Dimensions

1435

1750

2150

R 2"

Upper Outlet

R 2 "1/2

Lower Outlet

R 4"

1030

1030

630

630

70

70

H H1 H2 AA

YYH 150 Long 150 R 2 "1/2 R 4" 1030 710 702150

1435

1750

2150

YAKACIK Fire Hydrants

Bellows Body

Middle Body

Upper Body

Operating Nut

Seat

Spindle Bear

Upper Cover

Drain Valve Body

Nitrile Rubber

Design and modification rights are reserved

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Ductile Iron

0.7040

0.7040

0.7040

0.7040

0.7040

Ck 22 + 1.4408*

0.7040*

0.7040*

St-42 + al.G

St-42 + al.G

Nitrile Rubber

Ms-58

Ms-58

1.4310

Nitrile Rubber

Glass

Plastic

St-42

Ms-58

Ms-58

1.4021

8.8+Gal.

8.8+Gal.

8.8+Gal.

Nitrile Rubber

Nitrile Rubber

Nitrile Rubber

Nitrile Rubber

Nitrile Rubber

Al*

Al*

Nitrile Rubber

St-37

0.7040

St-37

Nitrile Rubber

Ductile Iron

DN 80-1 00

PN16

TS EN 14384

Flanged accordin

DIN EN 1092-2 P

According to TS 1

According to DIN 2

According to TS 3

YFH. F. __.__8

Page 6: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

YAKACIK Fire Hydrants

It is generally accepted that 3 (max. 4) hydrants are enough to extinguish a medium building fire in 3 to 15 minutes.

Quantity and Location

1-) Sufficient number of hydrant must be located outside of the building and two hoses must be connected.

Distance between hydrants:

In factories and depots

In residential areas

:

:

40-50 meters

150 meters

2-) Distance between the hydrant and the building should not be less than 12 meters under normal conditions.The closer the distance is, the higher the adverse effect of high temperature to hydrant usage.

3-) The hydrants must be located on smooth stones or concrete, the vicinity of automatic discharge (drain valve) must not be filled with gravels, shingles etc.

4-) The centre height of the union must not be less than 630 mm above the ground.

5-) When the pipes are to be replaced with the new ones, the new pipes must be cleaned before mounting.

Fire Hydrants Mounting Example

YAKACIK VALF Fire Hydrants Assembly Dimensions

Min

. 630

mm

1030

mm

1120

mm

long

770

mm

mid

dle

420

mm

shor

t

2150

mm

long

1800

mm

mid

dle

1450

mm

shor

t42

0 m

m

250

mm

500 mm

600 mm

Concrete

Gravel

Ground

200

mm

330

mm

800

mm

Size

DN 80

DN 100

Flow Single Outlet Flow Double Outlets

73* m³/h

116 m³/h

90 m³/h

128 m³/h

Design and modification rights are reserved

Hydromechanical tests of YAKACIK VALF Fire Hydrants were carried by ITUMechanical Engineering Department, Hydromechanical Laboratories with thereport number 96/21. The results are as follows:

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Page 7: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

Phone: 0216 309 72 50 Fax: 0216 377 98 01Phone: 0216 309 72 50 Fax: 0216 377 98 01

DN 150T : YYHypeShort Long-

* Upon request, 1.4408 may be produced

OutletsValve

TypeDN

YYH 150

Nom.Dia.

150

D

Dimensions

2150R 2" "1/2

Upper Outlet Lower Outlet

R 4" 1030 710 70

H H1 H2 AA

Design and modification rights are reserved

Long Tip

6

YYH 150 150 1435R 2" "1/2 R 4" 1030 710 70Short Tip

YAKACIK Fire Hydrants

Part NameP.No

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

32

33

34

35

36

37

Lower Body

Plug

Plug Nut

Plug Gasket

Drain Valve Spring

Drain Valve Nipple

Drain Valve Seat

Drain Valve Gasket

Drain Valve Ball

Drain Valve Discharging Hose

Stem 1"

Stem Pin

Guided Nut

Spindle

Setscrew M8x40

Bolt

Bolt

O-ring

O-ring

O-ring

O-ring

O-ring

Connection Cap

Union

Union Gasket

Union Chain

Elbow

Union Chain Fixing Ring

Cast Iron

GJL-250

GJL 250

GJL 250

GJL 250

GJL 250

Ck 22 + 1.4408*

0.7040*

0.7040*

St-42 + gal.

St-42 + gal.

NBR

Ms-58

Ms-58

1.4310

Glass

Plastic

St-42

Ms-58

Ms-58

1.4021

8.8+Gal.

8.8+Gal.

8.8+Gal.

NBR

NBR

NBR

NBR

NBR

Al*

Al*

NBR

St-37

GJL 250

St-37

Body

Middle Body

Upper Body

Operating Nut

Seat

Spindle Bear

Upper Cover

Drain Valve Body

Ductile Iron

0.7040

0.7040

0.7040

0.7040

0.7040

Ck 22 + 1.4408*

0.7040*

0.7040*

St-42 + gal.

St-42 + gal.

NBR

Ms-58

Ms-58

1.4310

Glass

Plastic

St-42

Ms-58

Ms-58

1.4021

8.8+Gal.

8.8+Gal.

8.8+Gal.

NBR

NBR

NBR

NBR

NBR

Al*

Al*

NBR

St-37

0.7040

St-37

31 O-ring NBR NBR

NBR NBR

NBR NBR

38

39

40

41

Connection Cap 4"

Union 4"

Union Gasket 4"

Union Chain 4"

GJL250

GJL250

NBR

St-37

0.7040

0.7040

NBR

St-37

Material Type

Size

Pressure Class

Dimensions

Assembly

Unions

Flanged Elbow

Hydrant Key

Order Code

DIN EN 1092-2 PN 16

Ductile Iron

DN 150

PN16

TS EN 14384

Flanged according to

DIN EN 1092-2 PN 16

According to TS 12258

According to DIN 28538

According to TS 37398

YFH. F. __.__8

Cast Iron

DN 150

PN16

TS EN 14384

Flanged according to

According to TS 12258

According to DIN 28538

According to TS 37398

YFH.2F. __.__

Page 8: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

YAKACIK Fire Hydrants

Economic, Easy to Service

Design and modification rights are reserved

When YAKACIK VALF Fire Hydrants are compared to one piece body hydrants, they are economically more advantageous.Since the upper body and the middle body are two seperate parts, it is cheaper to replace just the worn out part instead ofwhole one piece body.

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Page 9: W 0 / TRD 100 FIRE HYDRANTS hydrant.pdf · ATEX Piston Valves DN15 - DN50 Balanced Piston Valves DN65 - DN200 YX - GT Ring Sets DN15 - DN200 Bellows Sealed Globe Valves DN15 - DN300

CE 0045PED 2014/68/EU

AD 2000 - W 0MANUFACTURING QUALIFIED CERTIFICATE

ISO 9001-2015QUALITY MANAGEMENT SYSTEM

EACFIRE SAFEBALL / PISTON VALVES

ATEX

Piston Valves DN15 - DN50

Balanced Piston Valves DN65 - DN200

Y SetsX - GT Ring DN15 - DN200

Bellows Sealed Globe Valves DN15 - DN300

Globe Valves DN15 - DN300

Boiler Blowdown Valves DN32 - DN50

Ball Valves DN15 - DN 004

T Type Strainers DN15 - DN300

Y Type Strainers DN15 - DN500

Expansion Joints DN25 - DN2500

Manometer Cocks 1/2''

Ball Valves (for natural gas) D 15 - DN 00N 4

Ball Valves Monoball DN15 - DN100

Check Valves DN15 - DN300

Disc Check Valves D 25 - DN100N

Dual Plate Check Valves DN40 - DN400

Butterfly Valves DN32 - DN500

YAKACIK VALF Products

Cryogenic Valves DN15 - DN50

Level Gauges PBR - UPR - UPTY Y Y

Transparent Gauge Glass

Safety Valves DN 20 32 - DN 100 150x x

Fire Hydrants DN80 - DN150

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

Piston Valves DN15 - DN50

Balanced Piston Valves DN65 - DN200

Y SetsX - GT Ring DN15 - DN200

Bellows Sealed Globe Valves DN15 - DN300

Globe Valves DN15 - DN300

Boiler Blowdown Valves DN32 - DN50

Ball Valves

T Type Strainers DN15 - DN300

Y Type Strainers DN15 - DN500

Expansion Joints DN25 - DN2500

Manometer Cocks 1/2''

Ball Valves (for natural gas) D 15 - DN 00N 4

Ball Valves Monoball DN15 - DN100

Check Valves

Butterfly Valves DN32 - DN500

YAKACIK VALF Products

Cryogenic Valves DN15 - DN50

Level Gauges PBR - UPR - UPTY Y Y

Transparent Gauge Glass

Fire Hydrants

DN15 - DN 004

Disc Check Valves

Dual Plate Check Valves

Safety Valves

DN80 - DN150

DN40 - DN400

DN15 - DN300

D 25 - DN100N

DN 20 32 - DN 100 150x x

Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01

TA LUFT

KocaeliİzmirTrakya

Gsm :Gsm :Gsm :

+90 532 453 25 27+90 533 591 93 98+90 530 370 40 96

İstanbul Deri Organize Sanayi BölgesiTabak Sk. No:4 N7-2 Özel Parsel34956 Tuzla / iSTANBUL / TÜRKİYETel: +90 216 309 72 50 (Pbx) Faks: +90 216 377 98 01www.yakacikvalf.com.tr [email protected]

https://twitter.com/yakacikvalf

YAKACIK VALF A. .SAN. ve TİC. ŞYAKACIK VALF A. .SAN. ve TİC. Ş

https://facebook.com/yakacikvalf

YAKACIK VALF A. .SAN. ve TİC. ŞYAKACIK VALF A. .SAN. ve TİC. Ş

Ankara Gsm :+90 530 497 51 08