VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without...

10
VS-E-1 All specifications are subject to change without notice. Blank : PCB Type A : With cover L : L plate type Features • 30% Miniaturization from previous models. • 100% load at 50°C, suitable for industrial equipment. • 5 Years warranty (conditions applied) VS-E SERIES Single Output 50 - 150W COMP COM Model Output Voltage VS50E 50W VS75E 75W VS100E 100W VS150E 150W Output Current Efficiency(Typ) Output Current Efficiency(Typ) Output Current Efficiency(Typ) Output Current Efficiency(Typ) 3.3V 10A 80% 15A 80% 20A 80% 30A 80% 5V 10A 85% 15A 85% 20A 85% 30A 86% 12V 4.3A 85% 6.3A 85% 8.5A 85% 12.5A 87% 15V 3.5A 85% 5.0A 85% 7.0A 85% 10.0A 87% 24V 2.5A 85% 3.2A 86% 4.3A 86% 6.3A 87% 48V 1.3A 87% 1.6A 87% 2.2A 87% 3.2A 88% VS 50E -5 / Rated Output Voltage Series Name VS100E/L Low Voltage Directive Electrical Appliance and Material Safety Law (Input Voltage 100VAC) UL62368-1/ CSA62368-1 warranty Y E A R S Others Model Output Voltage VS50E 50W VS75E 75W VS100E 100W VS150E 150W /A /L /CO2 /FV /A /L /CO2 /FV /A /L /CO2 /FV /A /L /CO2 /FV 3.3V 5V 12V 15V 24V 48V VS150E/A VS50E VS75E Rated Output Power Product line up Applications Conformity to RoHS Directive Option line up EN62368-1 web190801

Transcript of VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without...

Page 1: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

VS-E-1・All speci�cations are subject to change without notice.

Blank : PCB TypeA : With coverL : L plate type

Features

• 30% Miniaturization from previous models.• 100% load at 50°C, suitable for industrial equipment.• 5 Years warranty (conditions applied)

VS-E SERIES Single Output 50 - 150W

VS-E Series用 途

Low Voltage DirectiveEN60950-1(TUV) Electrical Applianceand Material Safety Law(Input Voltage 100VAC)

UL60950-1CSA60950-1

COMP COM

Others

warranty

YEARS

Model

Output Voltage

VS50E

50W

VS75E

75W

VS100E

100W

VS150E

150W

Output Current Ef�ciency(Typ) Output Current Ef�ciency(Typ) Output Current Ef�ciency(Typ) Output Current Ef�ciency(Typ)

3.3V 10A 80% 15A 80% 20A 80% 30A 80%

5V 10A 85% 15A 85% 20A 85% 30A 86%

12V 4.3A 85% 6.3A 85% 8.5A 85% 12.5A 87%

15V 3.5A 85% 5.0A 85% 7.0A 85% 10.0A 87%

24V 2.5A 85% 3.2A 86% 4.3A 86% 6.3A 87%

48V 1.3A 87% 1.6A 87% 2.2A 87% 3.2A 88%

VS 50E -5 /

Rated Output Voltage

Series Name

VS100E/L

Low Voltage Directive Electrical Applianceand Material Safety Law(Input Voltage 100VAC)

UL62368-1/CSA62368-1

warranty

YEARS

VS-E SeriesLow Voltage Directive Electrical Appliance

and Material Safety Law(Input Voltage 100VAC)

Others

warranty

YEARS

Model

Output Voltage

VS50E

50W

VS75E

75W

VS100E

100W

VS150E

150W

/A /L /CO2 /FV /A /L /CO2 /FV /A /L /CO2 /FV /A /L /CO2 /FV

3.3V ○ ○ ◯ ‐ ○ ○ ○ ‐ ○ ○ ○ ‐ ○ ○ ○ ‐5V ○ ○ ○ ‐ ○ ○ ○ ‐ ○ ○ ○ ‐ ○ ○ ○ ‐12V ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○15V ○ ○ ○ ‐ ○ ○ ○ ‐ ○ ○ ○ ‐ ○ ○ ○ ‐24V ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○48V ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

VS150E/A

VS50E

VS75E

Rated Output Power

Product line up

Applications

Conformity to RoHS Directive

Option line up

EN62368-1

web190801

Page 2: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

VS 50E

VS-E-2 ・All speci�cations are subject to change without notice.

VS50E SpecificationsMODEL

ITEMS/UNITS VS50E-3 VS50E-5 VS50E-12 VS50E-15 VS50E-24 VS50E-48

Input

Voltage Range (*2) V AC 85 - 132

Frequency (*2) Hz 47 - 63

(*1) % 80 85 87

Current (Typ) (*1) A 0.9 1.1 1.3

Inrush Current (Typ) (*1)(*11) A 30 at Cold Start

Leakage Current (*8) mA Less than 0.5

Output

Nominal Voltage VDC 3.3 5 12 15 24 48

Maximum Current A 10 4.3 3.5 2.5 1.3

Maximum Power W 33.0 50.0 51.6 52.5 60.0 62.4

Maximum Line Regulation (*3)(*4) mV 20 48 60 96 192

Maximum Load Regulation (*3)(*5) mV 40 96 120 150 240

(*3) Less than 0.02% / °C

Maximum Ripple & Noise(0≤Ta≤70°C) (*3) mVp-p 120 150 200

Maximum Ripple & Noise(-10≤Ta<0°C) (*3) mVp-p 160 180 240

Hold-up Time (Typ) (*1) ms 20

Voltage Adjustable Range (*12) VDC 2.97 - 3.63 4.5 - 5.5 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 43.2 - 52.8

Function

Over Current Protection (*6) A 10.5 - 4.51 - 3.67 - 2.62 - 1.36 -

Over Voltage Protection (*7) VDC 3.80 - 4.46 5.75 - 6.75 13.8 - 16.2 17.3 - 20.3 27.6 - 32.4 55.2 - 64.8

Parallel Operation -

Series Operation Possible

Environment

Operating Temperature (*9) °C Convection : -10 - +70 (-10 - +50:100%, +60:70%, +70:20%)

Storage Temperature °C -30 - +85

Operating Humidity %RH 30 - 90 (No dewdrop)

Storage Humidity %RH 10 - 95 (No dewdrop)

Vibration At no operating, 10 - 55Hz (Sweep for 1min)

19.6m/s2 Constant, X,Y,Z 1hour each.

Shock Less than 196.1m/s2

Cooling Convection Cooling

IsolationWithstand Voltage

Input - FG : 2kVAC (10mA), Input - Output : 2kVAC (10mA)

Output - FG : 500VAC (20mA) for 1min

Isolation Resistance More than 100MΩ at 25°C and 70%RH Output - FG : 500VDC

Standards

Safety Standards

EMI Designed to meet EN55011/EN55032-B, FCC-B, VCCI-B

Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),

-5(Level 2,3), -6(Level 3), -8(Level 4), -11

MechanicalWeight (Typ) g 150

Size (W×H×D) (*10) mm 50 x 23 x 132 ( Refer to Outline Drawing )

*Read instruction manual carefully, before using the power supply unit.

(*1) At 100VAC, Ta=25°C, nominal output voltage and maximum output power.

(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 120VAC(50/60Hz).

(*3) Please refer to Fig. A for measurement of line & load regulation and ripple voltage.

(*4) 85 - 132VAC, constant load.

(*5) No load-Full load, constant input voltage.

(*6) Fold back current limit with automatic recovery. Avoid to operate at over load or short circuit condition for more than 30seconds.

(*7) OVP circuit will shut the output down, manual reset (Re power on).

(*8) Measured by the each measuring method of UL, CSA, EN and DENAN(at 60Hz), Ta=25°C.

(*9) Ratings - Derating at standard mounting. Refer to output derating curve(A239-01-02_).

- Load (%) is percent of maximum output power or maximum output current, whichever is greater.

(*10) Not include lead length on solder side.

(*11) Inrush Current suppressors type. Limits vary according to ambient temperature and in case of re-entry.

(*12)

Approved by UL62368-1, CSA62368-1, EN62368-1, EN50178(OV II), UL60950-1, CSA60950-1, EN60950-1.

(Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 12 (J60950-1).

Page 3: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

VS 50E

VS-E-�・All specifications are subject to change without notice.

Output Derating

OUTPUT DERATING CURVE12010080604020

0

Ta(°C)

VS50E-3, -5, -12, -15, -24

-10 0 10 20 30 40 50 60 70

70

80

LOA

D(%

)

(STANDARD MOUNTING)MOUNTING A MOUNTING B MOUNTING C

MOUNTING A - DMOUNTING E

VS50E-48

70

70 70

OUTPUT DERATING CURVE12010080604020

0

Ta(°C)-10 0 10 20 30 40 50 60 70 80

LOA

D(%

)

MOUNTING A - CMOUNTING D, E

CN1(INPUT)FIN

CN1 FIN

CN1

MOUNTING D MOUNTING E DON'T USE

CN1

CN1

CN1

VS50E-3/A, -5/A, -12/A, -15/A, -24/A

OUTPUT DERATING CURVE

LOA

D(%

)

0

20

40

60

80

100

120

-10 0 10 20 30 40 50 60 70Ta (°C)

VS50E-48/A

OUTPUT DERATING CURVE

LOA

D(%

)

0

20

40

60

80

100

120

-10 0 10 20 30 40 50 60 70Ta (°C)

VS50E Standard Specification, /CO2, /FV, /L

VS50E/A

MOUNTING A - DMOUNTING E

MOUNTING A - CMOUNTING D, E

MATCHING HOUSINGS & PIN.(NOT INCLUDED WITH THE PRODUCT.)

PART DESCRIPTION PART NAME MANUFACT QTY

SOCKET HOUSING (CN1) VHR-5N J.S.T. 1

SOCKET HOUSING (CN51) VHR-4N J.S.T. 1

Terminal pinSVH-21T-P1.1

J.S.T. 7BVH-21T-P1.1

HAND CRIMPING TOOL YC-160R J.S.T. -

(127.5)

122±0.5132±1

523±1

(5)

CN1

(29)

1

3

5

INPUT

NAME PLATE

L

N

50±

1

540

±0.

5

OUTPUT

(30)

1

(5)

(18)

3+ 4

-2

CN51VR51

(TAPPED HOLES)

VOLTAGEADJUSTMENT

COMPONENT SIDE

LEAD CUTLESS THAN 3mm

4- 3.5

Outline Drawing

CONNECTOR USED

PART DESCRIPTION PART NAME MANUFACT QTY

PIN HEADER (INPUT SIDE CN1) B3P5-VH(LF)(SN) J.S.T. 1

PIN HEADER(OUTPUT SIDE CN51) B4P-VH(LF)(SN) J.S.T. 1

* OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.

150±0.5

162±1150±0.5

6

1510

36±1

60±

120

±0.

540

±0.

5

INPUT

6

20

L

10

1

N

CN1

3

5

OUTPUT4321

+

-

30

CN51VR51

2- 3.5

3.5(FOR MOUNTING) R1.75(FOR MOUNTING)

R1.75(FOR MOUNTING)

2-M3(FOR MOUNTING)

4-M3(FOR MOUNTING)

NAME PLATE

(FOR MOUNTING)

VOLTAGEADJUSTMENT

150±0.5

162±1150±0.5

6

1510

36±1

60±

120

±0.

540

±0.

5

6

2010

R1.75(FOR MOUNTING)

R1.75(FOR MOUNTING)

2-M3(FOR MOUNTING)

4-M3(FOR MOUNTING)

30

1 L

CN1

3

5

N

+ 43

- 21

VR51CN51

INPUTOUTPUT

2- 3.5(FOR MOUNTING)

3.5(FOR MOUNTING)

NAMEPLATE

VOLTAGEADJUSTMENT

COMPONENT SIDE

VS50E Standard Specification, /CO2, /FV

OPEN HARNESS

PART NAME

INPUT HA-2-INOUTPUT HA-3-OU

VS50E/A VS50E/L

Page 4: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

VS-E-4 ・All speci�cations are subject to change without notice.

VS75E Specifications

VS 75E

MODELITEMS/UNITS VS75E-3 VS75E-5 VS75E-12 VS75E-15 VS75E-24 VS75E-48

Input

Voltage Range (*2) V AC 85 - 132

Frequency (*2) Hz 47 - 63

(*1) % 80 85 86 87

Current (Typ) (*1) A 1.1 1.6

Inrush Current (Typ) (*1)(*12) A 30A at Cold Start

Leakage Current (*9) mA Less than 0.5

Output

Nominal Voltage VDC 3.3 5 12 15 24 48

Maximum Current A 15 6.3 5.0 3.2 1.6

Maximum Power W 49.5 75.0 75.6 75.0 76.8

Maximum Line Regulation (*3)(*5) mV 20 48 60 96 192

Maximum Load Regulation (*3)(*6) mV 40 96 120 150 240

(*3) Less than 0.02% / °C

Maximum Ripple & Noise(0≤Ta≤70°C) (*3)(*4) mVp-p 120 150 200

Maximum Ripple & Noise(-10≤Ta<0°C) (*3)(*4) mVp-p 160 180 240

Hold-up Time (Typ) (*1) ms 20

Voltage Adjustable Range (*13) VDC 2.97 - 3.63 4.5 - 5.5 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 43.2 - 52.8

Function

Over Current Protection (*7) A 15.7 - 6.61 - 5.25 - 3.36 - 1.68 -

Over Voltage Protection (*8) VDC 3.80 - 4.46 5.75 - 6.75 13.8 - 16.2 17.3 - 20.3 27.6 - 32.4 55.2 - 64.8

Parallel Operation -

Series Operation Possible

Environment

Operating Temperature (*10) °C Convection : -10 - +70 (-10 - +50:100%, +60:70%, +70:20%)

Storage Temperature °C -30 - +85

Operating Humidity %RH 30 - 90 (No dewdrop)

Storage Humidity %RH 10 - 95 (No dewdrop)

Vibration At no operating, 10 - 55Hz (Sweep for 1min)

19.6m/s2 Constant, X, Y, Z 1hour each.

Shock Less than 196.1m/s2

Cooling Convection Cooling

IsolationWithstand Voltage

Input - FG : 2kVAC (10mA), Input - Output : 2kVAC (10mA)

Output - FG : 500VAC (20mA) for 1min

Isolation Resistance More than 100MΩ at 25°C and 70%RH Output - FG : 500VDC

Standards

Safety Standards

EMI Designed to meet EN55011/EN55032-B, FCC-B, VCCI-B

Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),

-5(Level 2,3), -6(Level 3), -8(Level 4), -11

MechanicalWeight (Typ) g 200

Size (W×H×D) (*11) mm 50 x 29 x 150 ( Refer to Outline Drawing )

*Read instruction manual carefully, before using the power supply unit.

(*1) At 100VAC, Ta=25°C, nominal output voltage and maximum output power.

(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 120VAC(50/60Hz).

(*3) Please refer to Fig. A for measurement of line & load regulation and ripple voltage.

(*4)

(*5) 85 - 132VAC, constant load.

(*6) No load-Full load, constant input voltage.

(*7) 3.3, 5V model : Constant current limit and hiccup with automatic recovery.

12 - 48V model : Constant current limit with automatic recovery.

Avoid to operate at over load or short circuit condition for more than 30seconds.

(*8) OVP circuit will shut the output down, manual reset (Re power on).

(*9) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25°C.

(*10) Ratings

- Derating at standard mounting. Refer to output derating curve(A240-01-02_).

- Load (%) is percent of maximum output power or maximum output current, whichever is greater.

(*11) Not include lead length on solder side.

(*12) Inrush Current suppressors type. Limits vary according to ambient temperature and in case of re-entry.

(*13)

Approved by UL62368-1, CSA62368-1, EN62368-1, EN50178(OV II), UL60950-1, CSA60950-1, EN60950-1.

(Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 12 (J60950-1).

Page 5: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

VS-E-�・All specifications are subject to change without notice.

Outline Drawing

VS 75E

CN1

1

3

5

L

N

VR51CN51

+65

-

4321

150±1

140±0.5

(108.5)

529±1

(5)

(29)

40±

0.5

5

50±

1

(6)

(22)

(5)

INPUT

NAME PLATE

OUTPUT

(TAPPED HOLES)

VOLTAGEADJUSTMENT

COMPONENT SIDE

LEAD CUTLESS THAN 3mm

4- 3.5

OUTPUT DERATING CURVE120

100

80

60

40

20

0

Ta (°C)

-10 0 10 20 30 40 50 60 70

70 70

80

LOA

D(%

)

MOUNTING A, BMOUNTING C - E

CN1

CN1

CN1

CN1(INPUT)

FIN

CN1 FIN

CN1

OUTPUT DERATING CURVE

LOA

D(%

)

0

20

40

60

80

100

120

-10 0 10 20 30 40 50 60 70Ta (°C)

MOUNTING A, BMOUNTING C - E

VS75EStandard Specification, /CO2, /FV, /L VS75E/A

(STANDARD MOUNTING)MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E DON'T USE

Output Derating

169±0.5

180±1169±0.5

15

5.5

15

45±1

L

N

60±

120

±0.

540

±0.

5

5.5

2010

1

CN1

3

5

30

3

VR51

6

45

21

CN51

+

-

2- 4.5(FOR MOUNTING)

R2.25(FOR MOUNTING)

R2.25(FOR MOUNTING)

4-M4(FOR MOUNTING)

INPUTOUTPUT

4.5(FOR MOUNTING)

2-M4(FOR MOUNTING)

NAMEPLATE

VOLTAGE ADJUSTMENT

169±0.5

180±1169±0.5

15

5.5

15

45±1

60±

120

±0.

540

±0.

5

5.5

2010

1 L

3 N

CN15

VR51

CN51

+65

-

4321

2- 4.5(FOR MOUNTING)

R2.25(FOR MOUNTING)

R2.25(FOR MOUNTING)

4-M4(FOR MOUNTING)

INPUT OUTPUT

4.5(FOR MOUNTING)

2-M4(FOR MOUNTING)

NAMEPLATE

VOLTAGE ADJUSTMENT

COMPONENT SIDE

VS75E/A

VS75E Standard Specification, /CO2, /FV

MATCHING HOUSINGS & PIN.(NOT INCLUDED WITH THE PRODUCT.)

PART DESCRIPTION PART NAME MANUFACT QTY

SOCKET HOUSING (CN1) VHR-5N J.S.T. 1

SOCKET HOUSING (CN51) VHR-6N J.S.T. 1

Terminal pinSVH-21T-P1.1

J.S.T. 9BVH-21T-P1.1

HAND CRIMPING TOOL YC-160R J.S.T. -

CONNECTOR USED

PART DESCRIPTION PART NAME MANUFACT QTY

PIN HEADER (INPUT SIDE CN1) B3P5-VH(LF)(SN) J.S.T. 1

PIN HEADER(OUTPUT SIDE CN51) B6P-VH(LF)(SN) J.S.T. 1

* OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.

OPEN HARNESS

PART NAME

INPUT HA-2-INOUTPUT HA-4-OU

VS75E/L

Page 6: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

VS-E-6 ・All speci�cations are subject to change without notice.

VS100E Specifications

VS 100E

MODELITEMS/UNITS VS100E-3 VS100E-5 VS100E-12 VS100E-15 VS100E-24 VS100E-48

Input

Voltage Range (*2) V AC 85 - 132 or DC 110 - 175

Frequency (*2) Hz 47 - 63

(*1) % 80 85 86 87

Current (Typ) (*1) A 1.6 2.1

Inrush Current (Typ) (*1)(*12) A 30A at Cold Start

Leakage Current (*9) mA Less than 0.5

Output

Nominal Voltage VDC 3.3 5 12 15 24 48

Maximum Current A 20 8.5 7.0 4.3 2.2

Maximum Power W 66.0 100.0 102.0 105.0 103.2 105.6

Maximum Line Regulation (*3)(*5) mV 20 48 60 96 192

Maximum Load Regulation (*3)(*6) mV 40 96 120 150 240

(*3) Less than 0.02% / °C

Maximum Ripple & Noise(0≤Ta≤70°C) (*3)(*4) mVp-p 120 150 200

Maximum Ripple & Noise(-10≤Ta<0°C) (*3)(*4) mVp-p 160 180 240

Hold-up Time (Typ) (*1) ms 20

Voltage Adjustable Range (*13) VDC 2.97 - 3.63 4.5 - 5.5 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 43.2 - 52.8

Function

Over Current Protection (*7) A 21.0 - 8.92 - 7.35 - 4.51 - 2.31 -

Over Voltage Protection (*8) VDC 3.80 - 4.46 5.75 - 6.75 13.8 - 16.2 17.3 - 20.3 27.6 - 32.4 55.2 - 64.8

Parallel Operation -

Series Operation Possible

Environment

Operating Temperature (*10) °C Convection : -10 - +70 (-10 - +50:100%, +60:70%, +70:20%)

Storage Temperature °C -30 - +85

Operating Humidity %RH 30 - 90 (No dewdrop)

Storage Humidity %RH 10 - 95 (No dewdrop)

Vibration At no operating, 10 - 55Hz (Sweep for 1min)

19.6m/s2 Constant, X,Y,Z 1hour each.

Shock Less than 196.1m/s2

Cooling Convection Cooling

IsolationWithstand Voltage

Input - FG : 2kVAC (10mA), Input - Output : 2kVAC (10mA)

Output - FG : 500VAC (20mA) for 1min

Isolation Resistance More than 100MΩ at 25°C and 70%RH Output - FG : 500VDC

Standards

Safety Standards

EMI Designed to meet EN55011/EN55032-B, FCC-B, VCCI-B

Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),

-5(Level 2,3), -6(Level 3), -8(Level 4), -11

MechanicalWeight (Typ) g 290

Size (W×H×D) (*11) mm 62 x 29 x 155 ( Refer to Outline Drawing )

*Read instruction manual carefully, before using the power supply unit.

(*1) At 100VAC, Ta=25°C, nominal output voltage and maximum output power.

(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 120VAC(50/60Hz).

(*3) Please refer to Fig. A for measurement of line & load regulation and ripple voltage.

(*4)

(*5) 85 - 132VAC, constant load.

(*6) No load-Full load, constant input voltage.

(*7) 3.3, 5V model: Constant current limit and hiccup with automatic recovery.

12 - 48V model: Constant current limit with automatic recovery.

Avoid to operate at over load or short circuit condition for more than 30seconds.

(*8) OVP circuit will shut the output down, manual reset (Re power on).

(*9) Measured by the each measuring method of UL, CSA, EN and DENAN(at 60Hz), Ta=25°C.

(*10) Ratings

- Derating at standard mounting. Refer to output derating curve(A241-01-02_).

- Load (%) is percent of maximum output power or maximum output current, whichever is greater.

(*11) Not include lead length on solder side.

(*12) Inrush Current suppressors type. Limits vary according to ambient temperature and in case of re-entry.

(*13)

Approved by UL62368-1, CSA62368-1, EN62368-1, EN50178(OV II), UL60950-1, CSA60950-1, EN60950-1.

(Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 12 (J60950-1).

Page 7: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

VS-E-�・All specifications are subject to change without notice.

Outline Drawing

VS 100E

1234

65

87

-

+

1

3

5

L

N

CN51

CN1

VR51

29±152

±0.

55

145±0.55

(5)

(6)

(26)

(22)

62±

1

155±1

(112)

(5)

INPUT

NAME PLATE

OUTPUT

(TAPPED HOLES)

VOLTAGE ADJUSTMENT

COMPONENT SIDE

LEAD CUTLESS THAN 3mm

4- 3.5

120

100

80

60

40

20

0-10 0 10 20 30 40 50 60 70

70 70

80

CN1

CN1

CN1

FIN

CN1 FIN

CN1

0

20

40

60

80

100

120

-10 0 10 20 30 40 50 55 60 70

MOUNTING A, BMOUNTING C, DMOUNTING E

VS100EStandard Specification, /CO2, /FV, /L VS100E/A

(STANDARD MOUNTING)MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E DON'T USE

CN1(INPUT)

Ta (°C)Ta (°C)

OUTPUT DERATING CURVE OUTPUT DERATING CURVE

LOA

D(%

)

LOA

D(%

)

MOUNTING A, BMOUNTING C - E

Output Derating

VS100E Standard Specification, /CO2, /FV

1445

±0.

524

25±

0.5

72±

1

6 173±0.5

185±1

36

45±1

2015

6 173.1±0.5

CN1

135

VR51

876543

CN51

21

N

L +

-

2- 4.5(FOR MOUNTING)

R2.25(FOR MOUNTING)

R2.25(FOR MOUNTING)

4-M4(FOR MOUNTING)

INPUTOUTPUT

4.5(FOR MOUNTING)

2-M4(FOR MOUNTING)

NAMEPLATE

VOLTAGE ADJUSTMENT

1445

±0.

524

25±

0.5

72±

1

6 173±0.5

185±1

36

45±1

2015

6 173±0.5

CN1L

N

VR51+

-

CN51

135

87654321

2- 4.5(FOR MOUNTING)

R2.25(FOR MOUNTING)

4-M4(FOR MOUNTING)

INPUT

OUTPUT

4.5(FOR MOUNTING)

NAMEPLATE

VOLTAGE ADJUSTMENT

R2.25(FOR MOUNTING)

2-M4(FOR MOUNTING)

COMPONENT SIDE

VS100E/A

MATCHING HOUSINGS & PIN.(NOT INCLUDED WITH THE PRODUCT.)

PART DESCRIPTION PART NAME MANUFACT QTY

SOCKET HOUSING (CN1) VHR-5N J.S.T. 1

SOCKET HOUSING (CN51) VHR-8N J.S.T. 1

Terminal pinSVH-21T-P1.1

J.S.T. 11BVH-21T-P1.1

HAND CRIMPING TOOL YC-160R J.S.T. -

CONNECTOR USED

PART DESCRIPTION PART NAME MANUFACT QTY

PIN HEADER (INPUT SIDE CN1) B3P5-VH(LF)(SN) J.S.T. 1

PIN HEADER(OUTPUT SIDE CN51) B8P-VH(LF)(SN) J.S.T. 1

* OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.

OPEN HARNESS

PART NAME

INPUT HA-2-INOUTPUT HA-5-OU

VS100E/L

Page 8: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

VS-E-8 ・All speci�cations are subject to change without notice.

VS150E Specifications

VS 150E

MODELITEMS/UNITS VS150E-3 VS150E-5 VS150E-12 VS150E-15 VS150E-24 VS150E-48

Input

Voltage Range (*2) V AC 85 - 132 or DC 110 - 175

Frequency (*2) Hz 47 - 63

(*1) % 80 86 87 88

Current (Typ) (*1) A 2.4 3.2

Inrush Current (Typ) (*1)(*12) A 30A at Cold Start

Leakage Current (*9) mA Less than 0.5

Output

Nominal Voltage VDC 3.3 5 12 15 24 48

Maximum Current A 30 12.5 10.0 6.3 3.2

Maximum Power W 99.0 150.0 151.2 153.6

Maximum Line Regulation (*3)(*5) mV 20 48 60 96 192

Maximum Load Regulation (*3)(*6) mV 40 96 120 150 240

(*3) Less than 0.02% / °C

Maximum Ripple & Noise(0≤Ta≤70°C) (*3)(*4) mVp-p 120 150 200

Maximum Ripple & Noise(-10≤Ta<0°C) (*3)(*4) mVp-p 160 180 240

Hold-up Time (Typ) (*1) ms 20

Voltage Adjustable Range (*13) VDC 2.97 - 3.63 4.5 - 5.5 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 43.2 - 52.8

Function

Over Current Protection (*7) A 31.5 - 13.12 - 10.5 - 6.61 - 3.36 -

Over Voltage Protection (*8) VDC 3.80 - 4.46 5.75 - 6.75 13.8 - 16.2 17.3 - 20.3 27.6 - 32.4 55.2 - 64.8

Parallel Operation -

Series Operation Possible

Environment

Operating Temperature (*10) °C Convection : -10 - +70 (-10 - +50:100%, +60:70%, +70:20%)

Storage Temperature °C -30 - +85

Operating Humidity %RH 30 - 90 (No dewdrop)

Storage Humidity %RH 10 - 95 (No dewdrop)

Vibration At no operating, 10 - 55Hz (Sweep for 1min)

19.6m/s2 Constant, X,Y,Z 1hour each.

Shock Less than 196.1m/s2

Cooling Convection Cooling

IsolationWithstand Voltage

Input - FG : 2kVAC (10mA), Input - Output : 2kVAC (10mA)

Output - FG : 500VAC (20mA) for 1min

Isolation Resistance More than 100MΩ at 25°C and 70%RH Output - FG : 500VDC

Standards

Safety Standards

EMI Designed to meet EN55011/EN55032-B, FCC-B, VCCI-B

Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),

-5(Level 2,3), -6(Level 3), -8(Level 4), -11

MechanicalWeight (Typ) g 390

Size (W×H×D) (*11) mm 75 x 34 x 160 ( Refer to Outline Drawing )

*Read instruction manual carefully, before using the power supply unit.

(*1) At 100VAC, Ta=25°C, nominal output voltage and maximum output power.

(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 120VAC(50/60Hz).

(*3) Please refer to Fig. A for measurement of line & load regulation and ripple voltage.

(*4)

(*5) 85 - 132VAC, constant load.

(*6) No load-Full load, constant input voltage.

(*7) 3.3, 5V model: Constant current limit and hiccup with automatic recovery.

12 - 48V model: Constant current limit with automatic recovery.

Avoid to operate at over load or short circuit condition for more than 30seconds.

(*8) OVP circuit will shut the output down, manual reset (Re power on).

(*9) Measured by the each measuring method of UL, CSA, EN and DENAN(at 60Hz), Ta=25°C.

(*10) Ratings

- Derating at standard mounting. Refer to output derating curve(A242-01-02_).

- Load (%) is percent of maximum output power or maximum output current, whichever is greater.

(*11) Not include lead length on solder side.

(*12) Inrush Current suppressors type. Limits vary according to ambient temperature and in case of re-entry.

(*13)

Approved by UL62368-1, CSA62368-1, EN62368-1, EN50178(OV II), UL60950-1, CSA60950-1, EN60950-1.

(Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 12 (J60950-1).

Page 9: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

・All specifications are subject to change without notice.

Outline Drawing

VS 150E

-

+

CN51

CN1

VR51

1

3

5

L

N

1

32

4

67

5

123

56

4

CN52

(7)

34±1

65±

0.5

5

150±0.55

(5)

(108)

(5)

(50)

(22)(3

3)

75±1

160±1

INPUT

NAME PLATE

OUTPUT

(TAPPED HOLES)

VOLTAGE ADJUSTMENT

COMPONENT SIDE

LEAD CUTLESS THAN 3mm

4- 3.5

120

100

80

60

40

20

0-10 0 10 20 30 40 50 60 70

70

80

70

55

FIN

CN1 FIN

CN1 CN1

CN1

CN1

0

20

40

60

80

100

120

-10 0 10 20 30 40 50 60 70

VS150E Standard Specification, /CO2, /FV, /L VS150E/A

(STANDARD MOUNTING)MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E DON'T USE

CN1(INPUT)

Ta (°C) Ta (°C)

OUTPUT DERATING CURVE OUTPUT DERATING CURVE

LOA

D(%

)

LOA

D(%

)

MOUNTING AMOUNTING B - E

MOUNTING AMOUNTING B - E

Output Derating

VS1150E Standard Specification, /CO2, /FV

VS150E/A

1555

±0.

525

35±

0.5

85±

1

6 176±0.5188±1

43

47±1

2015

6 176±0.5

CN1

1L

3N5

VR51CN515

6

43 +

-

21

76

3

54

21

CN52 R2.25(FOR MOUNTING)

R2.25(FOR MOUNTING)

4-M4(FOR MOUNTING)

INPUT OUTPUT

2-M4(FOR MOUNTING)

NAMEPLATE

VOLTAGE ADJUSTMENT

2- 4.5(FOR MOUNTING)

4.5(FOR MOUNTING)

VS150E/L

1555

±0.

525

35±

0.5

85±

1

6 176±0.5188±1

43

47±1

2015

6 176±0.5

CN1

L

N

VR51CN51

+

-

CN52

1

3

5

56

4321

76

3

54

21

R2.25(FOR MOUNTING)

R2.25(FOR MOUNTING)

4-M4(FOR MOUNTING)

INPUT

OUTPUT

2-M4(FOR MOUNTING)

NAMEPLATE

VOLTAGE ADJUSTMENT

2- 4.5(FOR MOUNTING)

4.5(FOR MOUNTING)

COMPONENT SIDE

MATCHING HOUSINGS & PIN.(NOT INCLUDED WITH THE PRODUCT.)

PART DESCRIPTION PART NAME MANUFACT QTY

SOCKET HOUSING (CN1) VHR-5N J.S.T. 1

SOCKET HOUSING (CN51) VHR-6N J.S.T. 1

SOCKET HOUSING (CN52) VHR-7N J.S.T. 1

Terminal pinSVH-21T-P1.1

J.S.T. 11BVH-21T-P1.1

HAND CRIMPING TOOL YC-160R J.S.T. -

CONNECTOR USED

PART DESCRIPTION PART NAME MANUFACT QTY

PIN HEADER (INPUT SIDE CN1) B3P5-VH(LF)(SN) J.S.T. 1

PIN HEADER(OUTPUT SIDE CN51) B6P-VH(LF)(SN) J.S.T. 1

PIN HEADER(OUTPUT SIDE CN52) B7P-VH(LF)(SN) J.S.T. 1

* OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.

OPEN HARNESS

PART NAME

INPUT HA-2-IN

OUTPUT+ : HA-6-OU− : HA-7-OU

VS-E-�

Page 10: VS-E SERIES Single Output 50 - 150W · VS 50E ・All specifications are subject to change without notice. VS-E- Output Derating OUTPUT DERATING CURVE 120 100 80 60 40 20 0 Ta(°C)

・All speci cations are subject to change without notice.

VS-E Series Instruction Manual

VS 50E, 75E, 100E, 150E

VS-E-10

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

VS-E Series Instruction Manual https://product.tdk.com/info/en/documents/instruction_manual/vs-e_apl.pdf