visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased....

16
RF-Capacitance Level Transmitter visit our website

Transcript of visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased....

Page 1: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

RF-Capacitance Level Transmitter

visit our website

Page 2: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

PRODUCT INTRODUCTION

EB3999 EB2600

PRINCIPLE

RF-Capacitance utilizes the capacitance formed between the sensing probe and the reference probe or the metal vessel wall to calculate the level of the liquid/medium inside the vessel according to the capacitance theory that the capacitance and vessel are proportional increased.

When sensing probe and detected media are fixed, media dielectric constant (Kmedia) is normally bigger than air (Kair=1). Capacitnce for media (Cmedia) increases when liquid/ power/ solid level raise. EB prouduct detects media level by calculating capacitance inside the tank.

level Transmitter

FEATURES

EB Series

4~20mA 2 wire Loop power

Low consumption of power (22mA Max)

High accuracy of linearity (< 1% FS)

Temperature compensation, low temperature

effect( 0.02% FS / C)

Easy calibration (Any 2 points for calibration)

Wide measuring range for capacitance

(0~5000pF)No blind distance, ideal for different tanks.

Suitable for high temperature, high pressure

and corrosive environment.

EB3 Series

EB2600 Series

2999

1

1

1 A

1

A B

1

1

1

1

999

1

1

1

1 Photocoupler x 2

1

1

1 Display range-1999~9999

1 Settings can be done directly with 3 buttons on

the housing.1 270B reversible direction for display.

1 Easy wiring with quick connector.

1 Easy installation with small product size.

1 Inclined plane desige, LCD display is easy to

be read.

Dual protection prevents fog from damaging PCB.

LCD indication is easy for observation from top.

Power Supply: 12~36Vdc

Protective housing with high stability prevents

from any damages during transportation, installation and operation.

Measuring accuracy is not affected by

temperature and pressure.

Recorder

PB SeriesBargraphicDisplay Panel Meter

PM SeriesDigital Display Panel Meter

EB2999

1

Level

4~20mA

Page 3: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

STANDARD TYPE

EB2100 Wire Probe EB2101 Hi-Temp Wire Probe EB2200 Rod Probe

SUS304

CERAMIC

-40~80BC

2000Kgf

4 ~20mA( )two wire

0~5000pF

2 3"x5kg/cm flange or 1"PT screw

Approx. 3.7kg(1M)

240kg/cm

12~36Vdc

SUS304

2000Kgf

4 ~20mA( )two wire

0~5000pF

Approx. 4.2kg(1M)

240kg/cm

2 3"x5kg/cm flange or 1"PT screw

12~36Vdc

-40~80BC

SUS304/316

4 ~20mA( )two wire

0~5000pF

2 1"x5kg/cm flange or 1"PT screw

Approx. 2.3kg(1M)

240kg/cm

12~36Vdc

-40~80BC

Measuring Range

Probe Material

Weight Material

Tensile Strength

Operation Voltage

Output Current

Accuracy

Weight

Operating Pressure

Operating Temperature

AmbientTemperature

Connection

Model No.

Dimensions

(unit:mm)

CERAMIC

A1%FS (25BC)A1%FS (25BC) A1%FS (25BC)

108

f113

21"x5kg/cmf120

1"PT

25

L=

4M (

Max

.)

1/2"NPT

f12.7

PP

108

f113

25

L=

50M

(M

ax.)

1/2"NPT

PP

SUS304

23"x5kg/cm

f120

1"PT

IP65 IP65 IP65Housing IP Degree

2

108

f113

L=

50M

(M

ax.)

1/2"NPT

PEEK

SUS304

61f88

25 23"x5kg/cm

f120

1"PT

-40~100BC -40~200BC -40~100BC

Suitable for big tankMedia : non-conductive material low moisture material

Suitable for big tankMedia : non-conductive material low moisture material

Suitable for middle/ small tankMedia : non-conductive material low moisture material

Page 4: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

STANDARD TYPE

EB2201 Hi-Temp Rod Probe

4 ~20mA( )two wire

IP65

Approx. 2.8kg(1M)

240kg/cm

2 1"x5kg/cm flange or 1"PT screw

SUS304/316

-40~80BC

EB2300 Wire Probe

SUS304

4 ~20mA( )two wire

IP65

2 1"x5kg/cm flange or 1"PT screw

Approx. 2.3kg(1M)

240kg/cm

SUS304

-40~80BC

EB2301 Hi-Temp Wire Probe

SUS304

4 ~20mA( )two wire

IP65

Approx. 2.8kg(1M)

240kg/cm

SUS304

2 1"x5kg/cm flange or 1"PT screw

-40~80BC

2000Kgf

0~5000pF

12~36Vdc

2000Kgf

0~5000pF

12~36Vdc

0~5000pF

12~36Vdc

Dimensions

(unit:mm)

A1%FS (25BC)A1%FS (25BC) A1%FS (25BC)

Measuring Range

Probe Material

Weight Material

Tensile Strength

Operation Voltage

Output Current

Accuracy

Weight

Operating Pressure

Operating Temperature

AmbientTemperature

Connection

Model No.

Housing IP Degree

3

108

f113

21"x5kg/cm

f120

1"PT

61

L=

50M

(M

ax.)

1/2"NPT

f88

PEEK

f28

M5100

SUS304

25

SUS304

108

f113

21"x5kg/cmf120

1"PT

25

L=

50M

(M

ax.)

1/2"NPT

f28

PP

SUS304

M5100

SUS304

108

f113

21"x5kg/cm

f120

1"PT

61

L=

4M (

Max

.)1/2"NPT

f12.7

PEEK

f88

25

-40~200BC -40~100BC -40~200BC

Suitable for non-conductive/ low moisture material and big tank.(weight can not be fixed at the bottom of tank)

Suitable for non-conductive/ low moisture material and big tank.(weight can not be fixed at the bottom of tank)

Suitable for middle/ small tankMedia : non-conductive material low moisture material

Page 5: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

STANDARD TYPE

EB2400 --- PVDF CoatingEB2420 --- PP CoatingEB2430 --- FEP Coating

EB2400/20/30 Anti-Corrosion EB2431

SUS304+Coating

4 ~20mA( )two wire

Approx. 2.3kg(1M)

240kg/cm

-40~80BC

4 ~20mA( )two wire

Approx. 2.3kg(1M)

240kg/cm

SUS304+Coating

-40~80BC

0~5000pF

12~36Vdc

0~5000pF

12~36Vdc

Dimensions

(unit:mm)

EB2520 --- PP CoatingEB2530 --- FEP Coating

EB2520/30 Anti-CorrosionWire Probe

4 ~20mA( )two wire

Approx. 2.3kg(1M)

240kg/cm

1200Kgf

SUS304+PTFE

SUS304+Coating

-40~80BC

0~5000pF

12~36Vdc

Hi-temp Anti-Corrosion

A1%FS (25BC)A1%FS (25BC) A1%FS (25BC)

Measuring Range

Probe Material

Weight Material

Tensile Strength

Operation Voltage

Output Current

Accuracy

Weight

Operating Pressure

Operating Temperature

AmbientTemperature

Connection

Model No.

108

f113

21"x5kg/cm

f120

1"PT

25

L=

50M

(M

ax.)

1/2"NPT

f28

PP

M8150

PTFE

108

f113

21"x5kg/cmf120

L=

4M (

Max

.)1/2"NPT

108

f113

61

1/2"NPT

f88

21"x5kg/cmf120

L=

4M (

Max

.)

IP65 IP65 IP65Housing IP Degree

2 1"x5kg/cm flange 2 1"x5kg/cm flange 2 1"x5kg/cm flange or 1"PT screw

4

-40~200BC-40~100BC -40~100BC

Suitable for conductive/ corrosive material and middle-size tank.

Suitable for conductive/ corrosive material and middle-size tank.

Suitable for conductive/ corrosive material and middle-size tank.(weight can not be fixed at the bottom of tank)

Page 6: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

STANDARD TYPE

Dimensions

(unit:mm)

4 ~20mA( )two wire

Approx. 2.3kg(1M)

240kg/cm

2000Kgf

SUS304+PTFE

SUS304+Coating

-40~100BC

-40~200BC

0~5000pF

12~36Vdc

EB2531 Anti-CorrosionHi-Temp Wire Probe

A1%FS (25BC)

Measuring Range

Probe Material

Weight Material

Tensile Strength

Operation Voltage

Output Current

Accuracy

Weight

Operating Pressure

Operating Temperature

AmbientTemperature

Connection

Model No.

108

f113

21"x5kg/cm

f120

1"PT

61

L=

50M

(M

ax.)

1/2"NPT

f88

PEEK

f28

M5100

25

PTFE

IP65Housing IP Degree

2 1"x5kg/cm flange or 1"PT screw

5

Suitable for conductive/ corrosive material and middle-size tank.(weight can not be fixed at the bottom of tank)

Page 7: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

EB3400 --- PVDF CoatingEB3420 --- PP CoatingEB3430 --- FEP Coating

EB3300 Wire ProbeModel No.

Dimensions

(unit:mm)

EB3200 Rod Probe

SUS304Probe material SUS304/316

4 ~20mA( )two wireOutput current 4 ~20mA( )two wire

0~5000pFMeasuring Range 0~5000pF

Accuracy

IP65Housing IP Degree IP65

Connection2 1"x5kg/cm flange or 1"PT screw

Approx. 2.3kg(1M)Weight Approx. 2.3kg(1M)

240kg/cmOperating pressure

240kg/cm

SUS304Weight material

2000KgfTensile strength

12~36VdcOperation voltage 12~36Vdc

-40~80BCAmbientTemperature -40~80BC

Operating Temperature

22mA

3.5mA

3.5、22mA

3.8~21.5mAOutput Linear Range

Output Latch

Lower Limit

Upper Limit 22mA

3.5mA

3.5、22mA

3.8~21.5mA

STANDARD TYPE (MULTI-FUNCTION)

A1%FS (25BC)A1%FS (25BC)

21"x5kg/cm

f120

1"PT

25

L=

50M

(M

ax.)

f28

PP

SUS304

M5100

SUS304

f84

105

35

1/2"PF

21"x5kg/cm

f120

1"PT

25

L=

4M (

Max

.)

f12.7

PP

f84

105

35

1/2"PF

21"x5kg/cmf120

L=

4M (

Max

.)

f84

105

35

1/2"PF

EB3400/20/30 Anti-Corrosion

0~5000pF

SUS304+Coating

12~36Vdc

4 ~20mA(two wire)

Approx. 2.3kg(1M)

240kg/cm

IP65

-40~80BC

2 1"x5kg/cm flange

22mA

3.5mA

3.5、22mA

3.8~21.5mA

A1%FS (25BC)

2 1"x5kg/cm flange or 1"PT screw

6

-40~100BC -40~100BC-40~100BC

Suitable for non-conductive material and middle-size tank.

Suitable for non-conductive material and big tank.

Suitable for conductive/ corrosive material and middle-size tank.

Page 8: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

12~36Vdc

4~20mA( )two wire

-40LC~100LC

0~85%

A LC0.02% FS. /

-1999 ~ 9999

IP 65

-40LC~80LC

尺寸圖

(單位:mm)

EB2600 Compact Ramp

0~1000pF

A1%FS (25BC)

Measuring Range

Probe material

Weight material

Tensile strength

Operation voltage

Output current

Accuracy

Weight

Operating pressure

Housing IP Degree

Operating Temperature

AmbientTemperature

Connection

Model No.

Dimensions

(unit:mm)

(Vs- 12) x 50

Vs:Power Voltage

Environment Temperature

Output current

Accuracy

Load Resistance

Operation Temperature

LCD Display

Housing IP Degree

Temperature Coefficient

Model No.

Power supply

Measuring range

Environment Humidity

Dimensions

(unit:mm)

22mA

3.5mA

3.5、22mA

3.8~21.5mAOutput Linear Range

Output Latch

Lower Limit

Upper Limit

Output Linear Range

Output Latch

Lower Limit

Upper Limit

STANDARD TYPE (MULTI-FUNCTION) / COMPACT RAMP

EB3520 --- PP CoatingEB3530 --- FEP Coating

EB3520/30 Anti-CorrosionWire Probe

SUS304+Coating

4 ~20mA( )two wire

0~5000pF

IP65

Approx. 2.3kg(1M)

215kg/cm

SUS304+PTFE

2000Kgf

12~36Vdc

-40~80BC

22mA

3.5mA

3.5、22mA

3.8~21.5mA

A1%FS (25BC)

21"x5kg/cmf120

1"PT

25

L=

50M

(M

ax.)

f28

PP

M8150

PTFE

f84

105

35

1/2"PF

2 1"x5kg/cm flange or 1"PT screw

7

-40~100BC

Suitable for conductive/ corrosive material and middle-size tank.

Suitable for conductive/ corrosive material and small tank.

f38.1

130

HEX38

1/2"PT22

49.5

L=1M(Max.)

f8

M12

Page 9: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

CALIBRATION & SETUP

8

Display Value

2sec

Setting mode

G:

Q:

H:

R:

I:

S:

A:

K:

U:

B:

L:

V:

C:

M:

W:

N:

D:

X:

O:

E:

Y:

T:

J: F:

P:

Z:

ON, OFF

1~60sec

OFF

1

Output latch

Reflash time

0~3

-1999~9999

-1999~9999

-1999~9999

-1999~9999

-1999~9999

-1999~9999

0~99

1

100.0

0

100.0

0

50.00

0

50.00

0

0

-1999~9999

-1999~9999

0~99

SAVE,RSET BACK

SAVE,RSET BACK

Lo,MID,HI

SAVE

SAVE

LO

/

/

EB3 Series

Capacity Value

High point Capacity Value

Low point Capacity Value

4mA fine turn

20mA fine turn

Load default

0~9999

0~9999 5056

0~9999 54

-1999~9999 0

-1999~9999 0

EB2 Series EB2600 Series

Alarm mode Control mode System mode

Main Menu

Sub-Menu

Range Default Description

Decimal point setting

20mA corresponding display value

4mA corresponding display value

Corresponding calibration value for high point (Hipt).Corresponding Calibration Value for low point (Lopt). Process High AlarmAlarm position

Hysteresis Alarm

Alarm delay time(sec)

Process Low AlarmAlarm position

Hysteresis Alarm

Alarm delay time(sec)

Software Filter

Memory for max & mini value during operation.SAVE:Save value into EepromREST:Clean present value and memoryBACK:Go back to sub-menu

Alarm direction :normal open :normal close

Alarm direction :normal open :normal close

Page 10: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

ORDER INFORMATION

32 --- Rod Type33 --- Wire Probe Type34 --- Anti-Corrosion (3400: PVDF 3420: PP 3430: FEP)35 --- Anti-Corrosion with Wire-probe weight (3520: PP 3530: FEP)21 --- Wire Probe Type21 --- Hi-Temp Wire Probe Type22 --- Rod Type22 --- Hi-Temp Rod Probe Type23 --- Wire Probe Type23 --- Hi-Temp Wire ProbeType24 --- Anti-Corrosion (2400: PVDF 2420: PP 2430: FEP)25 --- Anti-Corrosion with Wire-probe weight (2520: PP 2530: FEP)26 --- Compact Ramp

Connecting

* Tolerance of the total product length isK5mm * Characteristics, specifications and dimensions are subject to change without notice. * Please contact your nearest distributing office for further informations.

EB 2 1 6 0 H M 5 0 0 0

Material

C --- 3/4" (EB2600)D --- 1"E --- 1-1/2"F --- 2"G --- 2-1/2"H --- 3"I --- 4"J --- 5"K --- 6"S --- others

B --- 1/2" (EB2600) 2M --- 5kg/cm2N --- 10kg/cm

O --- 150 LbsP --- 300 LbsQ --- PTR --- PF(G)T --- BSPU --- NPTV --- GASS --- others

Dimension Specification

Probe Length (unit: mm)

3: Multi-function Type 2: Standard Type

Metal Probe:Plastic Coated Probe:

0:SUS304 6: SUS316 0:PVDF 2: PP 3: FEP

0: (max.100LC)1: Hi-Temp Type (max.200LC)

Standard

0500: below 500mm

1000: 501~1000mm

1500: 1001~1500mm 500mm per Unit

Use English letter as first code for probe length over 10m.A150 represents 15m, A200 represents 20m

Temperature Resistance

9

Page 11: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

EXPLOSION PROOF TYPE

EB1710 Wire Probe EB1711 Hi-Temp Wire Probe EB1720 Rod Probe

SUS304

CERAMIC

-20~70BC

-40~80BC

2000Kgf

4 ~20mA( )two wire

0~5000pF

IP65

2 3"x5kg/cm flange or 1-1/2"PT screw

Approx. 3.7kg(1M)

12~36Vdc

SUS304

2000Kgf

4 ~20mA( )two wire

0~5000pF

IP65

Approx. 4.2kg(1M)

2 3"x5kg/cm flange or 1-1/2"PT screw

12~36Vdc

-20~70BC

-40~200BC

SUS304/316

4 ~20mA( )two wire

0~5000pF

IP65

2 1-1/2"x5kg/cm flange or 1-1/2"PT screw

Approx. 2.3kg(1M)

12~36Vdc

-20~70BC

-40~80BC

Measuring Range

Probe material

Weight material

Tensile strength

Operation voltage

Output current

Accuracy

Weight

Operating pressure

Housing IP Degree

Operating Temperature

AmbientTemperature

Connection

Model No.

Dimensions

(unit:mm)

CERAMIC

PTB PROOF No.09 ATEX 1004 II 2G Ex d IIB T6~T3 GbII 2D Ex tb IIIC T80BC~T190BCDb IP65

A1%FS (25BC)A1%FS (25BC) A1%FS (25BC)

f95

f12.7

4-f15

L=

4M (

Max

.)

21-1/2"x5kg/cmf120

1-1/2"PT

f21

108

f113

1/2"NPT

25

10

ceramic

f1454-f19

L=

50M

(M

ax.)

23"x5kg/cmf180

1-1/2"PT45

f20

125

f113

1/2"NPT

25

4-f19

L=

50M

(M

ax.)

23"x5kg/cm

f145

f180

50f88

1-1/2"PT42

f20

108

f113

1/2"NPT

25

ceramic

240kg/cm240kg/cm 240kg/cm

Suitable for non-conductive material and big tank.

Suitable for non-conductive material and big tank.

Suitable for non-conductive material and middle-size tank.

Page 12: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

EXPLOSION PROOF TYPE

EB1721 Hi-Temp Rod Probe

4 ~20mA( )two wire

IP65

Approx. 2.8kg(1M)

2 1-1/2"x5kg/cm flange

or 1-1/2"PT screw

SUS304/316

-20~70BC

-40~200BC

EB1730 Wire Probe

SUS304

4 ~20mA( )two wire

IP65

Approx. 2.3kg(1M)

SUS304

-20~70BC

-40~80BC

EB1731 Hi-Temp Wire Probe

SUS304

4 ~20mA( )two wire

IP65

Approx. 2.8kg(1M)

SUS304

-20~70BC

-40~200BC

2000Kgf

0~5000pF

12~36Vdc

2000Kgf

0~5000pF

12~36Vdc

0~5000pF

12~36Vdc

Measuring Range

Probe material

Weight material

Tensile strength

Operation voltage

Output current

Accuracy

Weight

Operating pressure

Housing IP Degree

Operating Temperature

AmbientTemperature

Connection

Model No.

Dimensions

(unit:mm)

2 2"x5kg/cm flange

or 1-1/2"PT screw

2 2"x5kg/cm flange

or 1-1/2"PT screw

A1%FS (25BC)A1%FS (25BC) A1%FS (25BC)

f95

f12.7

4-f15

L=

4M (

Max

.)

21-1/2"x5kg/cmf120

f88

f21

1-1/2"PT

108

f113

1/2"NPT

50

25

f1454-f19

22"x5kg/cmf180

SUS304150

L=

50M

(M

ax.)

f38

f9.5 wire

108

f113

1/2"NPT

f20

42

25

1-1/2"PTf88

50

108

f113

1/2"NPT

f1454-f19

22"x5kg/cmf180

SUS304150

L=

50M

(M

ax.)

f38

f9.5 wire

f20

42

25

1-1/2"PT

11

240kg/cm240kg/cm 240kg/cm

Suitable for non-conductive material and big tank.

Suitable for non-conductive material and middle-size tank.

Suitable for non-conductive material and big tank.

PTB PROOF No.09 ATEX 1004 II 2G Ex d IIB T6~T3 GbII 2D Ex tb IIIC T80BC~T190BCDb IP65

Page 13: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

EXPLOSION PROOF TYPE

EB1740 --- PVDF CoatingEB1742 --- PP CoatingEB1743 --- FEP Coating

EB1740/42/43 Anti-Corrosion

SUS304+Coating

4 ~20mA( )two wire

IP65

Approx. 2.3kg(1M)

-20~70BC

0~5000pF

12~36Vdc

Measuring Range

Probe material

Weight material

Tensile strength

Operation voltage

Output current

Accuracy

Weight

Operating pressure

Housing IP Degree

Operating Temperature

AmbientTemperature

Connection

Model No.

Dimensions

(unit:mm)

EB1752 --- PP CoatingEB1753 --- FEP Coating

EB1752/53 Anti-CorrosionWire Probe

4 ~20mA( )two wire

A1%FS (25BC)

IP65

Approx. 2.3kg(1M)

2000Kgf

SUS304+PTFE

SUS304+Coating

-20~70BC

0~5000pF

12~36Vdc

2 1-1/2"x5kg/cm flange

or 1-1/2"PT screw

2 2"x5kg/cm flange

or 1-1/2"PT screw

A1%FS (25BC)

f95

4-f15

21-1/2"x5kg/cmf120

1-1/2"PT25

f16

f12

L=

4M (

Max

.)108

f113

1/2"NPT

150

PTFE

f38

f145

f8 wire

4-f19

L=

50M

(M

ax.)

22"x5kg/cmf180

1-1/2"PT42

f20

125

f113

1/2"NPT

25

f5

12

240kg/cm240kg/cm

-40~80BC -40~80BC

Suitable for conductive/ corrosive material and middle-size tank.

Suitable for conductive/ corrosive material and big tank.(weight can not be fixed at the bottom of tank)

PTB PROOF No.09 ATEX 1004 II 2G Ex d IIB T6~T3 GbII 2D Ex tb IIIC T80BC~T190BCDb IP65

Page 14: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

1710 --- Wire Probe Type

1711 --- Hi-Temp Wire Probe Type

1720 --- Rod Type

1721 --- Hi-Temp Rod Probe Type

1730 --- Wire Probe Type

1731 --- Hi-Temp Wire ProbeType

1749 --- Anti-Corrosion (1740: PVDF 1742: PP 1743: FEP)

1759 --- Anti-Corrosion with Wire-probe weight

(1752: PP 1753: FEP)

Connecting

* Tolerance of the total product length is 5mm

* Characteristics, specifications and dimensions are subject to change without notice. * Please contact your nearest distributing office for further informations.

K

EB 1 7 1 0 H M 5 0 0 0

E --- 1-1/2"F --- 2"G --- 2-1/2"H --- 3"I --- 4"J --- 5"K --- 6"S --- others

D --- 1" 2M --- 5kg/cm2N --- 10kg/cm

O --- 150 LbsP --- 300 LbsQ --- PTR --- PF(G)T --- BSPU --- NPTV --- GASS --- others

Dimension Specification

Probe Length (unit: mm)

0500: below 500mm

1000: 501~1000mm

1500: 1001~1500mm 500mm per Unit

Use English letter as first code for probe length over 10m.A150 represents 15m, A200 represents 20m

13

ORDER INFORMATION

Page 15: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

Metal strap

Rod probe

Rod probe

Isolate supporter

Ceramic isolator

Cable probe

Rod probe

Agitator

Vent holeTube

Fig. 1

Fig. 2

Fig. 4Fig. 3

INSTALLATION

1. The rod probe or cable probe (depending upon which one you purchased ) should be parallel to the tank wall and be positioned as close as possible to the tank wall. Make sure the medium does not stick in between the probe and the tank wall.

2. If the tank is not electrically conductive, a metal strap should be added outside of tank wall (fig. 1) for either liquid or non-liquid medium. Or place a metal tube, usually made out of stainless steel, around the rod (fig. 2) for liquid medium. This metal tube should come with a vent hole at top of the tube to allow the medium to go up inside of the tube.

3. If the container is irregular-shaped, such as a cylindrical, and the medium is liquid with low viscosity, the rod should be placed inside a metal tube with vent hole at the top. (Fig. 2)

4. For non-conductive medium of powder or granuules in a new or empty tank, the cable probe should be fixed to the bottom of tank with ceramic isolator (EB2100 Series. If the tank is not empty, please use the EB2300 Series. (fig. 3)

5. Make sure to fix the rod probe or cable probe to the container wall with non-conductive supporting material. If an agitator is in place (see fig. 4). This will prevent the deformation of the rod probe and tangling of the cable probe around the agitator.

6. If the medium is conductive, make sure to coat the rod probe or cable probe with PVDF or PP material.

7. During the installation, the process connection should be grounded. An installation without proper grounding will not guarantee normal operation of the device later on.

8. When all electrical connections inside of a Capacitance Level Transducer housing are finished, the housing cover and the conduit opening should be sealed and tightened to prevent moisture from soaking in.

14

Page 16: visit our website RF-Capacitance Level... · capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia)

[SF] Paddle Flow Switch

[FC/FD] Mini Float/Magnetic Float Level Switch

[SD] Optical Level Switch

[FA/FB] Cable Float Level Switch

[FF] Side Mounting Float Switch

[SB] RF-Capacitance / Admittance Level Switch

[SE] Rotary Paddle Level Switch

[SC] Vibrating Probe Level Switch

[SC] Tuning Fork Level Switch

[LR] Loop Power Indicator

[SA] Capacitance Level Switch

[SP] Thermal Dispersion Flow Switch

[EC] Pressure Level Transmitter

[ED] Speed Monitor

[PB/PM] Microprocessor Based Bargraphic Display Scaling Meter

[BRD/AE] Valve and Controller for Dust Collector System

[EB] RF-Capacitance Level Transmitter

[FG] Magnetic Float Level Transmitter

[EG] Magnetostrictive Level Transmitter

[EA] Ultrasonic Level Transmitter

[EF] By-Pass Level Transmitter

[MEF] Mini By-Pass Level Transmitter

[BAS/BAH/BVP] Air Hammer

[BVK/BVR/BVT] Pneumatic Vibrator

[JFR] FMCW Radar Level Transmitter

[EE] Electromechanical Level Measuring System

[SRT/SRS] Conveyer Belt Misalignment Switch &

Safety Cable Pull Switch

08-EB-B0-EP, 01/17/2012

Distributor:

[FA/FB]

[PB]

[EG]

[SF]

[EF]

[JFR] [FC/FD]

[EC]

[FF]

[SA]

[EB]

[EA]

[FG]

[SP]

[SC]

[SB]

[FC/FD] [SD]

[LR]

[EB]

[SE]

[PB/PM]

[EB]

[EE] [EA]

[BAS/BAH/BVP]

[BVK/BVR/BVT]

[EB]

[SA]

[SB]

[SC]

[SC]

[SC] [JFR] [SE]

[SB]

FineTek Co., Ltd.

TEL: 886 2 2269 6789 FAX: 886 2 2268 6682Email: [email protected] http://www.fine-tek.com

Taichung Branch TEL: 886 4 2465 2820 FAX: 886 4 2463 9926Tainan Branch TEL: 886 6 289 0635 FAX: 886 6 289 4073Kaohsiung Branch TEL: 886 7 333 6968 FAX: 886 7 536 8758

Fine automation (ShangHai) Co., Ltd.No.451 DuHui Rd, MinHang District, Shanghai, China 201109TEL: 86 21 6490 7260 FAX: 86 21 6490 7276Email: [email protected]

FineTek Pte Ltd.No. 11 Kaki Bukit Road 1,#04-01 Eunos Technolink 415939, Singapore TEL: 65 6452 6340 FAX: 65 6734 1878Email: [email protected]

FineTek GmbHFrankfurter Str. 62, OG D-65428 Ruesselsehim, GermanyTEL: 49 6142 17608 0 FAX: 49 6142 17608 20Email: [email protected]

Aplus Finetek Sensor inc.355 S. Lemon Ave, Suite D, Walnut, CA 91789TEL: 1 909 598 2488 FAX : 1 909 598 3188Email: [email protected]

No.16, Tzuchiang St., Tucheng Industrial Park, New Taipei City 23678, Taiwan.