VISION CONTROL FEATURES R - Unicel

50
ARCHITECTURAL Unicel Architectural Corp. 2155 Fernand-Lafontaine Longueuil • Québec • J4G 2J4 • Canada T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144 E: unicel@unicelarchitectural.com • www.unicelarchitectural.com VC 1.1 2020 7 2 8 1 4 3 5 6 9 A primary seal made of polyisobutylene is used for its high resistance against ultraviolet rays and is combined to a secondary seal made of high quality silicone. The tubular profile contains a highly effective drying agent, providing moisture-free air space between glass panels. The unique hollow-chambered louvers provide maximum rigidity and strength and maintain the parallel alignment of the blades for utmost privacy and light control. The 2 1/2" (63.5mm) dehydrated airspace reduces noise, providing sound attenuation superior to insulating glass units with standard airspaces. 2" (50.8mm) airspace available. All pivots, pinions, and racks are made of u.v. stabilized material to ensure dimensional stability, durability, never needing lubrication. Various glazing products and polycarbonates are available according to applications and project needs. The rack is made of corrosion-resistant aluminum. The gear housing (for crank handles, knobs and motors) is mechanically attached to the frame. The fingertip crank handles, thumbwheels and knobs operators are made of long-lasting plastic, zinc, brass or aluminum, easy to rotate and requiring no maintenance. 1 2 3 4 5 6 7 8 9 VISION CONTROL ® FEATURES

Transcript of VISION CONTROL FEATURES R - Unicel

Page 1: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.1

2020

7

2

8

1

4

3

5 6

9

A primary seal made of polyisobutylene is used for its high resistance against ultraviolet rays and is combined to a

secondary seal made of high quality silicone.

The tubular profile contains a highly effective drying agent, providing moisture-free air space between glass panels.

The unique hollow-chambered louvers provide maximum rigidity and strength and maintain the parallel alignment of

the blades for utmost privacy and light control.

The 2 1/2" (63.5mm) dehydrated airspace reduces noise, providing sound attenuation superior to insulating glass

units with standard airspaces. 2" (50.8mm) airspace available.

All pivots, pinions, and racks are made of u.v. stabilized material to ensure dimensional stability, durability, never

needing lubrication.

Various glazing products and polycarbonates are available according to applications and project needs.

The rack is made of corrosion-resistant aluminum.

The gear housing (for crank handles, knobs and motors) is mechanically attached to the frame.

The fingertip crank handles, thumbwheels and knobs operators are made of long-lasting plastic, zinc, brass or

aluminum, easy to rotate and requiring no maintenance.

1

2

3

4

5

6

7

8

9

VISION CONTROL

®

FEATURES

AutoCAD SHX Text
R
Page 2: VISION CONTROL FEATURES R - Unicel

54mm

2 1/8''

57.9

mm

2 9/32

''

B

1

B

STANDARD HEIGHT

1

B

2

B

NON-STANDARD HEIGHT

2

BB

NON-STANDARD HEIGHT

3

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.2.1

2020

VISION CONTROL

®

HANDLE / KNOB POSITION

25.6mm

1''

GEAR

HOUSING

17.2m

m

11/16''

50

.8

mm

2''

18.1mm

23/32''

54m

m

2 1/8

''

9.5mm

3/8''

4.76m

m

3/16''

161.9m

m

6 3/8"

VA

RIE

S

166.7m

m

6 9/16"

171.5m

m

6 3/4"

9.5m

m

3/8''

REFER TO STANDARD GLASS SIZES FOR HEIGHTS ON PAGE VC 1.6

OPTIONAL OPERATORS:

LOUVERS BETWEEN INSULATING GLASS

MANUALLY OPERATED

OPTION : ELECTRICALLY OPERATED

A

B

(N

ON

-S

TA

ND

AR

D LO

CA

TIO

N

FO

R O

PE

RA

TO

RS

A

VA

ILA

BLE

)

AIR

S

PA

CE

* VISIBLE SEALANT

AT PERIMETER

3/4" (19.1mm) Ø

ALUMINUM KNOB

1" (25.4mm) Ø

ALUMINUM KNOB

FOLDABLE ZINC

CRANK HANDLE

(WHITE OR GRAY)

31/32'' (24.6mm) Ø

BRASS LIGATURE-RESISTANT KNOB

(PAINTED WHITE OR GRAY)

- WHITE K-1285

- GRAY K-20794

- CUSTOM COLORS

FOLDABLE ZINC

CRANK HANDLE

(WHITE OR GRAY)

ALUMINUM FINISH:

STANDARD DURACRON

- GLOSSY WHITE K-1285

- METALLIC GRAY K-20794

1 IN

CR

EM

EN

T

2 IN

CR

EM

EN

TS

A

TYPICAL DETAIL TYPICAL DETAIL

B

AutoCAD SHX Text
R
Page 3: VISION CONTROL FEATURES R - Unicel

63.5mm

2 1/2''

B

1

B

1

B

2

B

2

BB

3

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.2.2

2020

25.6mm

1''

17

.2

mm

11

/1

6''

50

.8

mm

2''

BA

18.1mm

23/32''

8.7mm

11/32''

4.7

6m

m

3/1

6''

18

7.3

mm

7 3

/8

"

2 IN

CR

EM

EN

TS

9.5

mm

3/8

''

A

B

19

2.1

mm

7 9

/1

6"

19

6.9

mm

7 3

/4

"

AIR

S

PA

CE

STANDARD HEIGHTNON-STANDARD HEIGHT NON-STANDARD HEIGHT

VISION CONTROL

®

THUMBWHEEL POSITION

TYPICAL DETAIL TYPICAL DETAIL

ALUMINUM FINISH:

STANDARD DURACRON

- GLOSSY WHITE K-1285

- METALLIC GRAY K-20794

* SEALANT REVEAL

AT PERIMETER

VA

RIE

S

VA

RIE

S

REFER TO STANDARD GLASS SIZES FOR HEIGHTS ON PAGE VC 1.6

LOUVERS BETWEEN INSULATING GLASS

MANUALLY OPERATED

OPTION : ELECTRICALLY OPERATED

(N

ON

-S

TA

ND

AR

D LO

CA

TIO

N

FO

R O

PE

RA

TO

RS

A

VA

ILA

BLE

)

OPTIONAL OPERATORS:

FAN-SHAPED THUMBWHEEL OPERATOR

(VARIABLE DIAMETER)

- WHITE ALUMINUM

- GRAY ALUMINUM

- BLACK POLYMER

FULL THUMBWHEEL OPERATOR

(VARIABLE DIAMETER)

- WHITE ALUMINUM

- GRAY ALUMINUM

- BLACK POLYMER

1 IN

CR

EM

EN

T

AutoCAD SHX Text
R
Page 4: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.2.3

2021

VISION CONTROL

®

QUICKGLIDE

TM

OPERATOR

POSITION

B

A

TYPICAL DETAIL

TYPICAL DETAIL

INTEGRATED LOUVERS BETWEEN INSULATING

GLASS - MANUALLY OPERATED

QUICKGLIDE

TM

OPERATOR

- WHITE

- GRAY

AIR

S

PA

CE

50

.8

mm

2''

63.6mm

2 1/2''

17.1mm

11/16''

* VISIBLE SEALANT

AT PERIMETER

33.5mm

1 5/16''

36.3mm

1 7/16''

18

mm

23

/3

2''

ALUMINUM FINISH:

STANDARD DURACRON

- GLOSSY WHITE K-1285

- METALLIC GRAY K-20794

6mm (1/4") CLEAR

TEMPERED GLASS

63.5mm

2 1/2''

18

7.3

mm

7 3

/8

"

17

.1

mm

11

/1

6''

STANDARD HEIGHT

B

1

NON-STANDARD HEIGHT

19

2.1

mm

7 9

/1

6"

17

.1

mm

11

/1

6''

4.8

mm

3/1

6''

1 IN

CR

EM

EN

T

B

2

NON-STANDARD HEIGHT

19

6.9

mm

7 3

/4

"

17

.1

mm

11

/1

6''

9.5

mm

3/8

''

2 IN

CR

EM

EN

TS

REFER TO STANDARD GLASS SIZES FOR HEIGHTS ON PAGE VC 1.6

(N

ON

-S

TA

ND

AR

D LO

CA

TIO

N

FO

R O

PE

RA

TO

RS

A

VA

ILA

BLE

)

A

B

20

9.7

mm

8 1

/4

''

12

0m

m

4 2

3/3

2''

MIN

IM

UM

35

2.4

mm

13

7

/8

"

AutoCAD SHX Text
R
Page 5: VISION CONTROL FEATURES R - Unicel

48 in. = 1.219 m

1219mm

48''

5810 in.

2

= 3.75 m

2

1473mm

58''

1727mm

68''

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.3

50.8mm

2''

50.8mm

2''

50.8mm

2''

58 in. = 1.473 m4640 in.

2

= 2.99 m

2

68 in. = 1.727 m4080 in.

2

= 2.63 m

2

6.4

mm

1/4

''

9.5

mm

3/8

''

12.7

mm

1/2

''

35.6m

m

1 13/32''

33

.3

mm

1 5

/1

6''

35.6m

m

1 13/32''

33

.3

mm

1 5

/1

6''

35.6m

m

1 13/32''

33

.3

mm

1 5

/1

6''

63.5mm

2 1/2''

2020

3 3/4 in. = 95.3 mm 3 3/4 in. = 95.3 mm 3 3/4 in. = 95.3 mm

MAXIMUM AREA MAXIMUM WIDTH MAXIMUM AREA MAXIMUM WIDTH

MAXIMUM GLASS SIZE

MAXIMUM AREA MAXIMUM WIDTH

VISION CONTROL

®

BLADE TYPES, AIRSPACES AND

MINIMUM / MAXIMUM SIZES

- VISION CONTROL

®

GLASS PANELS ARE MADE WITH INTERLOCKING BLADES,

OFFERING TOTAL PRIVACY AND OPTIMAL LIGHT CONTROL WHEN CLOSED.

- GLASS SIZE LIMITATIONS AND THICKNESSES TO BE DETERMINED BY UNICEL'S ENGINEERING DEPARTMENT.

- TWO AIRSPACE THICKNESSES ARE AVAILABLE: 2" AND 2 1/2" (50.8mm AND 63.5mm)

- THREE BLADE THICKNESSES ARE AVAILABLE: 1/4", 3/8" AND 1/2" (6.4mm, 9.5mm AND 12.7mm)

* If required sizes are outside of feasibility range, please contact Unicel for special arrangements.

MAX. WIDTH

MAXIMUM GLASS SIZEMAXIMUM GLASS SIZE

MAX. WIDTH MAX. WIDTH

OPTIONAL SPACER:

MINIMUM WIDTH

MINIMUM GLASS SIZE

MINIMUM WIDTH

MINIMUM GLASS SIZE

MINIMUM WIDTH

MINIMUM GLASS SIZE

AutoCAD SHX Text
R
Page 6: VISION CONTROL FEATURES R - Unicel

20.6mm

13/16''

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.4

96" (2438mm)

116" (2946mm)

136" (3454mm)

1/4" (6.4mm)

3/8" (9.5mm)

1/2" (12.7mm)

12.7mm

1/2''

2020

12.7mm

1/2''

MAXIMUM GLASS WIDTH

VISION CONTROL

®

DOUBLE PANELS

MAXIMUM GLASS WIDTH BLADE TYPE

CLEARANCE

REQUIRED

CLEARANCE

REQUIRED

MIDDLE INNER

SPACER

VISION CONTROL

®

PANEL

GEAR HOUSING

2 1/8'' x 2 9/32''

(54mm x 57.9mm)

FOLDABLE ZINC

CRANK HANDLE

DETAIL

ELEVATION

MIDDLE INNER SPACER FOR INTERMEDIATE LOUVER SUPPORT

AutoCAD SHX Text
R
Page 7: VISION CONTROL FEATURES R - Unicel

A

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.5

2020

53.2mm

50

.8

mm

2''

39.4mm

1 9/16''

2 3/32''

A

A

TYPICAL DETAIL

RIGHT-ANGLED TRIANGLE TRAPEZOIDAL

GEAR HOUSING

2 1/8'' X 2 9/32''

(54mm X 57.9mm)

VISION CONTROL

®

RIGHT-ANGLED TRIANGLE

AND TRAPEZOIDAL SHAPE

AutoCAD SHX Text
R
Page 8: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.6

2020

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

1376.4

1409.7

1443.0

1476.4

1509.7

1543.1

1576.4

1609.7

1643.1

1676.4

1709.7

1743.1

1776.4

1809.8

1843.1

1876.4

1909.8

1943.1

1976.4

2009.8

2043.1

2076.5

2109.8

2143.1

2176.5

2209.8

2243.1

2276.5

2309.8

2343.2

2376.5

2409.8

2443.2

2476.5

2509.8

2543.2

2576.5

54 3/16

55 1/2

56 13/16

58 1/8

59 7/16

60 3/4

62 1/16

63 3/8

64 11/16

66

67 5/16

68 5/8

69 15/16

71 1/4

72 9/16

73 7/8

75 3/16

76 1/2

77 13/16

79 1/8

80 7/16

81 3/4

83 1/16

84 3/8

85 11/16

87

88 5/16

89 5/8

90 15/16

92 1/4

93 9/16

94 7/8

96 3/16

97 1/2

98 13/16

100 1/8

101 7/16

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

2609.9

2643.2

2676.5

2709.9

2743.2

2776.5

2809.9

2843.2

2876.6

2909.9

2943.2

2976.6

3009.9

3043.2

3076.6

3109.9

3143.3

3176.6

3209.9

3243.3

3276.6

3309.9

3343.3

3376.6

3410.0

3443.3

3476.6

3510.0

3543.3

3576.6

3610.0

3643.3

3676.7

3710.0

3743.3

3776.7

3810.0

102 3/4

104 1/16

105 3/8

106 11/16

108

109 5/16

110 5/8

111 15/16

113 1/4

114 9/16

115 7/8

117 3/16

118 1/2

119 13/16

121 1/8

122 7/16

123 3/4

125 1/16

126 3/8

127 11/16

129

130 5/16

131 5/8

132 15/16

134 1/4

135 9/16

136 7/8

138 3/16

139 1/2

140 13/16

142 1/8

143 7/16

144 3/4

146 1/16

147 3/8

148 11/16

150

142.9

176.2

209.6

242.9

276.2

309.6

342.9

376.2

409.6

442.9

476.3

509.6

542.9

576.3

609.6

642.9

676.3

709.6

743.0

776.3

809.6

843.0

876.3

909.6

943.0

976.3

1009.7

1043.0

1076.3

1109.7

1143.0

1176.3

1209.7

1243.0

1276.4

1309.7

1343.0

5 5/8

6 15/16

8 1/4

9 9/16

10 7/8

12 3/16

13 1/2

14 13/16

16 1/8

17 7/16

18 3/4

20 1/16

21 3/8

22 11/16

24

25 5/16

26 5/8

27 15/16

29 1/4

30 9/16

31 7/8

33 3/16

34 1/2

35 13/16

37 1/8

38 7/16

39 3/4

41 1/16

42 3/8

43 11/16

45

46 5/16

47 5/8

48 15/16

50 1/4

51 9/16

52 7/8

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

METRIC (mm)IMPERIAL (")# BLADES METRIC (mm)IMPERIAL (")# BLADES # BLADES METRIC (mm)IMPERIAL (")

VISION CONTROL

®

HEIGHT CHART

STANDARD GLASS SIZES FOR HEIGHTS*

(FOR HORIZONTAL LOUVERS ONLY)**

*NON-STANDARD GLASS HEIGHTS ARE ALSO AVAILABLE BY ADDING SERIES OF 3/16"(4.76mm) INCREMENTS TO ANY GIVEN STANDARD HEIGHT (SEE PAGE VC 1.2.1 & 1.2.2)

**FOR VERTICAL LOUVERS, THIS CHART CAN BE INTERPRETED AS STANDARD GLASS SIZES FOR WIDTHS

AutoCAD SHX Text
R
Page 9: VISION CONTROL FEATURES R - Unicel

50.8mm

2''

X YX Y

X Y

63.5mm

2 1/2''

63.5mm

2 1/2''

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.7

2020

50.8mm

2''

X Y

1/4" (6mm) 2" (50.8mm) 1/4" (6mm) 41

1/4" (6mm) 2 1/2" (63.5mm) 42

1/4" (6mm) 45

1/4" (6mm) 46

3/8" (10mm) 48

1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm) 50

1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm) 51

2" (50.8mm)

2" (50.8mm)

2" (50.8mm)

2" (50.8mm)

2 1/2" (63.5mm)

1/4" (6mm)

1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm)

3/16" - .060" PVB - 3/16" (5mm - 1.6mm PVB - 5mm)

1/4" - .060" PVB - 1/4" (6mm - 1.6mm PVB - 6mm)

1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm)

1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm)

NOTE:

ALL DATA SHOULD BE VERIFIED VIA TESTING THE ACTUAL WINDOW ASSEMBLY TO ASCERTAIN THE EFFECTS OF WINDOW FRAMES ON TOTAL WINDOW SYSTEM SOUND TRANSMISSION LOSS.

ALL DATA WERE ESTIMATED (DERIVED FROM TESTED SAMPLES COMPARABLE IN CONFIGURATION TO THOSE ABOVE) AND ARE NOT GUARANTEED FOR ALL SAMPLES OR APPLICATIONS.

VISION CONTROL

®

ACOUSTICAL GLAZING

SOUND CONTROL GLASS

VISION CONTROL

®

IS AVAILABLE WITH VARIOUS GLASS TYPES AND THICKNESSES WITH THE OPTION

OF 2" (50.8mm) OR 2 1/2" (63.5mm) AIRSPACE, OFFERING EXCEPTIONAL SOUND DAMPING CHARACTERISTICS.

IGU AVAILABLE

WITHOUT BLADES

EXAMPLES OF STC RATINGS WITH VARYING GLASS CONFIGURATIONS

GLASS LITE X AIRSPACE GLASS LITE Y STC (ESTIMATED)

AutoCAD SHX Text
R
Page 10: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 1.8

2020

17.5mm

11/16"

81mm

3 3/16"

17.5mm

11/16"

76.2mm

3"

= =

12

.7

mm

1/2

"

7.9mm

5/16"

7.9mm

5/16"

7.9

mm

5/1

6"

6.4

mm

1/4

"

3.2

mm

1/8

"

1/4

"

6m

m

1 19/32"

40mm

15

.9

mm

5/8

"

12

.7

mm

1/2

"

A A

4

8

"

-

9

6

"

1

2

1

9

.

2

m

m

-

2

4

3

8

.

4

m

m

19.1mm

3/4"

28

.6

mm

1 1

/8

"

VISION CONTROL

®

ACCESSORIES

GLASS STOPS THUMBWHEEL COVER

HOLE(2) 9/64" (3.6mm) Ø COUNTERSINK (HS #4)

SCREW #6 X 3/4" (19.1mm)

STAINLESS STEEL PHILLIPS OVAL HEAD

EXTENSION POLE

HEXAGONAL SOCKET

EXTENSION POLE

FOR OUT-OF-REACH VISION CONTROL

®

UNITS

VISION CONTROL

®

PANEL

HEXAGONAL

SOCKET

OVAL PLATE

OVAL PLATE

SNAP-ON COVER

STANDARD FINISHES*

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

GLASS STOPS

* OTHER FINISHES AVAILABLE UPON REQUEST.

25.4mm

1"

44

.5

mm

1 3

/4

"

25.4mm

1"

44

.5

mm

1 3

/4

"

BEHAVIORAL / MENTAL

HEALTH

APPLICATION

AutoCAD SHX Text
R
Page 11: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.1

2020

AC

B

C

A B

50

.8

mm

2''

63.5mm

2 1/2''

28

.6

mm

1 1

/8

''

1.6mm

1/16''

1.6mm

1/16''

19.1mm

3/4''

12

.7

mm

1/2

''

16

1.9

mm

6 3

/8

''

28.6mm

1 1/8''

12.7mm

1/2''

19

.1

mm

3/4

''

63

.5

mm

2 1

/2

''

1.6

mm

1/1

6''

1.6

mm

1/1

6''

12.7mm

1/2''

12

.7

mm

1/2

''

16

1.9

mm

6 3

/8

''

50

.8

mm

2''

25.4mm

1''

28

.6

mm

1 1

/8

''

SETTING BLOCK

BY OTHERS

STEEL FRAME

BY OTHERS

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

GEAR HOUSING

FOLDABLE ZINC

CRANK HANDLE

(OPTIONAL)

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

CLEARANCE

REQUIRED

GEAR

HOUSING

FOLDABLE ZINC

CRANK HANDLE

VISION CONTROL

®

PANEL

ALUMINUM

GLASS STOPS

BY UNICEL

SETTING BLOCK

BY OTHERS

OVAL PLATE

VISION CONTROL

®

INTERIOR WALL

HOLLOW METAL FRAME

CRANK HANDLE OPERABLE ON ONE OR BOTH SIDE(S)

STANDARD FINISHES*

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

LOUVERS GLASS STOPS

* OTHER FINISHES AVAILABLE UPON REQUEST.

VISION CONTROL

®

PANEL

FOLDABLE ZINC

CRANK HANDLE

FOLDABLE ZINC

CRANK HANDLE

FOLDABLE ZINC

CRANK HANDLE

(OPTIONAL)

ROUNDED ALUMINUM

EXTENSION BLOCK

ROUNDED ALUMINUM

EXTENSION BLOCK

OVAL

PLATE

ROUNDED ALUMINUM

EXTENSION BLOCK

AutoCAD SHX Text
R
Page 12: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.2

2020

A A

B B

28.6mm

1 1/8''

9.5mm

3/8''

63

.5

mm

2 1

/2

''

9.5

mm

3/8

''

19

.1

mm

3/4

''

A

B

28.6mm

1 1/8''

9.5mm

3/8''

50

.8

mm

2''

9.5

mm

3/8

''

19

.1

mm

3/4

''

50.8mm

2''

28

.6

mm

1 1

/8

''

12

.7

mm

1/2

''

18

7.3

mm

7 3

/8

''

19.1mm

3/4''

50.8mm

2''

19.1mm

3/4''

9.5mm

3/8''

28

.6

mm

1 1

/8

''

12

.7

mm

1/2

''

18

7.3

mm

7 3

/8

''

9.5mm

3/8''

9.5mm

3/8''

9.5mm

3/8''

9.5mm

3/8''

VISION CONTROL

®

INTERIOR WALL

HOLLOW METAL FRAME

THUMBWHEEL OPERABLE ON ONE OR BOTH SIDE(S)

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

CLEARANCE

REQUIRED

VISION CONTROL

®

PANEL

CLEARANCE

REQUIRED

SETTING BLOCK

BY OTHERS

STEEL FRAME

BY OTHERS

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

FULL THUMBWHEEL

OPERATOR

(VARIABLE DIAMETER)

CU

T-O

UT

CU

T-O

UT

CU

T-O

UT

CU

T-O

UT

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

VISION CONTROL

®

PANEL

ACCESSIBLE ON BOTH SIDES ACCESSIBLE ON ONE SIDE

SETTING BLOCK

BY OTHERS

STEEL FRAME

BY OTHERS

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

FAN-SHAPED

THUMBWHEEL OPERATOR

(VARIABLE DIAMETER)

CU

T-O

UT

CU

T-O

UT

FAN-SHAPED

THUMBWHEEL OPERATOR

(VARIABLE DIAMETER)

STANDARD FINISHES*

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

LOUVERS GLASS STOPS

* OTHER FINISHES AVAILABLE UPON REQUEST.

FULL THUMBWHEEL OPERATOR

(VARIABLE DIAMETER)

± 115°

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME DOWN

FROM OPERABLE SIDE

AutoCAD SHX Text
R
Page 13: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.3

2020

A B

DC

1.6mm

1/16''

50.8mm

2''

1.6mm

1/16''

25.4mm

1''

16

1.9

mm

6 3

/8

''

50

.8

mm

2''

12

.7

mm

1/2

''

28

.6

mm

1 1

/8

''

50.8mm

2''

1.6mm

1/16''

1.6mm

1/16''

25.4mm

1''

12

.7

mm

1/2

''

28

.6

mm

1 1

/8

''

50

.8

mm

2''

25.4mm

1''

16

1.9

mm

6 3

/8

''

50

.8

mm

2''

12

.7

mm

1/2

''

28

.6

mm

1 1

/8

''

C

50.8mm

2''

1.6mm

1/16''

1.6mm

1/16''

50.8mm

2''

1.6mm

1/16''

1.6mm

1/16''

25.4mm

1''

12

.7

mm

1/2

''

28

.6

mm

1 1

/8

''

B

D

16

1.9

mm

6 3

/8

''

SETTING BLOCK

BY OTHERS

X-RAY SHIELDING

LEAD GLASS

VISION CONTROL

®

PANEL

LEAD LINING

BY OTHERS

UN

IC

EL

RE

CO

MM

EN

DS

STEEL FRAME &

GLASS STOPS

BY OTHERS

VISION CONTROL

®

PANEL

3/8" (10mm)

POLYCARBONATE

SETTING BLOCK

BY OTHERS

DETAIL - INTERIOR

X-RAY SHIELDING

FOLDABLE REMOVABLE

ZINC CRANK HANDLE

UN

IC

EL

RE

CO

MM

EN

DS

SETTING BLOCK

BY OTHERS

PYROSTOP

FIRE-RATED

GLASS (45 MIN;

60 MIN; 90 MIN)

VISION CONTROL

®

PANEL

FIRE-RATED

STEEL FRAME &

GLASS STOPS

BY OTHERS

UN

IC

EL

RE

CO

MM

EN

DS

DETAIL - INTERIOR

FIRE-RATED

VARIES

SETTING BLOCK

BY OTHERS

VISION CONTROL

®

PANEL

STEEL FRAME &

GLASS STOPS

BY OTHERS

UN

IC

EL

RE

CO

MM

EN

DS

STEEL FRAME &

GLASS STOPS

BY OTHERS

HEXAGONAL

SOCKET

DETAIL - INTERIOR

POLYCARBONATE

DETAIL - INTERIOR

VERTICAL LOUVERS

VISION CONTROL

®

INTERIOR WALL

HOLLOW METAL FRAMES

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

A

VARIABLE

MIN

. 1

2.7

mm

1/2

"

ROUNDED ALUMINUM

EXTENSION BLOCK

ROUNDED

ALUMINUM

EXTENSION

BLOCK

ROUNDED ALUMINUM

EXTENSION BLOCK

ROUNDED ALUMINUM

EXTENSION BLOCK

OVAL

PLATE

OVAL

PLATE

OVAL

PLATE

AutoCAD SHX Text
R
Page 14: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.4

2020

E F

HG

50.8mm

2''

18

7.3

mm

7 3

/8

''

19.1mm

3/4''

9.5mm

3/8''

127mm OR 152.4mm

5" OR 6"

12

.7

mm

1/2

''

50.8mm

2''

18

7.3

mm

7 3

/8

''

19.1mm

3/4''

9.5mm

3/8''

12

.7

mm

1/2

''

44

.5

mm

1 3

/4

''

1.6mm

1/16''

1.6mm

1/16''

50

.8

mm

2''

16

1.9

mm

6 3

/8

''

50.8mm

2''

25.4mm

1''

12

.7

mm

1/2

''

50.8mm

2''

44

.4

mm

1 3

/4

''

28

.6

mm

1 1

/8

''

19.1mm

3/4''

19.1mm

3/4''

5" OR 6"

127mm OR 152.4mm

19.1mm

3/4''

12

.7

mm

1/2

''

28

.6

mm

1 1

/8

''

1.6mm

1/16''

44

.5

mm

1 3

/4

''

16

1.9

mm

6 3

/8

''

50

.8

mm

2''

28

.6

mm

1 1

/8

''

28

.6

mm

1 1

/8

''

6.4

mm

1/4

''

E F

G H

6.4

mm

1/4

''

FULL THUMBWHEEL

OPERATOR

(VARIABLE DIAMETER)

SETTING BLOCK

BY OTHERS

VISION CONTROL

®

PANEL

ALUMINUM FRAME &

GLASS STOPS

BY UNICEL

SETTING BLOCK

BY OTHERS

FAN-SHAPED

THUMBWHEEL OPERATOR

(VARIABLE DIAMETER)

VISION CONTROL

®

PANEL

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

WOOD FRAME

BY OTHERS

ALUMINUM

SNAP-ON

GLASS STOPS

BY UNICEL

SETTING BLOCK

BY OTHERS

VISION CONTROL

®

PANEL

STEEL FRAME

BY OTHERS

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

SETTING BLOCK

BY OTHERS

VISION CONTROL

®

PANEL

ALUMINUM FRAME

& GLASS STOPS

BY UNICEL

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

CU

T-O

UT

CU

T-O

UT

CU

T-O

UT

CU

T-O

UT

VISION CONTROL

®

INTERIOR WALL

VARIOUS FRAMES

CU

T-O

UT

CU

T-O

UT

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

DETAIL - INTERIOR DETAIL - INTERIOR

WOOD FRAME

DETAIL - INTERIORDETAIL - INTERIOR

FRAME BY UNICEL RABETTED FRAME

FRAME BY UNICEL

± 115°

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME DOWN

FROM OPERABLE SIDE

ROUNDED ALUMINUM

EXTENSION BLOCK

ROUNDED ALUMINUM

EXTENSION BLOCK

OVAL

PLATE

OVAL

PLATE

AutoCAD SHX Text
R
Page 15: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.5

2020

9.5mm

3/8''

50.8mm

2''

1.6mm

1/16''

19.1mm

3/4''

1.6mm

1/16''

19.1mm

3/4''

9.5mm

3/8''

50.8mm

2''

12

.7

mm

1/2

''

28.6mm

1 1/8''

18

7.3

mm

7 3

/8

''

9.5mm

3/8''

28

.6

mm

1 1

/8

''

B

A

BA

28

.6

mm

1 1

/8

''

VISION CONTROL

®

INTERIOR WALL

SOUND OR SMOKE BARRIER

FAN-SHAPED

THUMBWHEEL

(VARIABLE DIAMETER)

FAN-SHAPED

THUMBWHEEL

(VARIABLE DIAMETER)

SOUND OR

SMOKE BARRIER

BY OTHERS

VISION CONTROL

®

PANEL

STEEL FRAME

BY OTHERS

SETTING BLOCK

BY OTHERS

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

DETAIL DETAIL

SOUND OR

SMOKE BARRIER

BY OTHERS

STANDARD FINISHES*

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

LOUVERS GLASS STOPS

* OTHER FINISHES AVAILABLE UPON REQUEST.

DOUBLE FAN-SHAPED THUMBWHEEL OPERABLE ON BOTH SIDES

± 115°

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME DOWN

FROM OPERABLE SIDE

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME UP

FROM OPERABLE SIDE

± 115°

VA

RIE

S

AutoCAD SHX Text
R
Page 16: VISION CONTROL FEATURES R - Unicel

C

B

A

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.6

A

2020

VISION CONTROL

®

INTERIOR WALL

CORNER CONFIGURATIONS

INTERIOR

DETAIL

BUTT-GLAZED WITH CORNER BRAKE METAL

9.5mm

3/8''

9.5

mm

3/8

''

19

.1

mm

3/4

''

19

.1

mm

3/4

''

63

.5

mm

2 1

/2

''

19.1mm

3/4''

19.1mm

3/4''

63.5mm

2 1/2''

33

.4

mm

1 5

/1

6''

1.6

mm

1/1

6''

1.6

mm

1/1

6''

91.4mm

3 19/32''

17

mm

21

/3

2''

22

.7

mm

29

/3

2''

5.2mm

7/32''

3.2mm

1/8''

12.1mm

15/32''

9

0

°

1.6mm

1/16''

1.6mm

1/16''

9.5mm

3/8''

9.5

mm

3/8

''

FAN-SHAPED THUMBWHEEL OPERATOR ACCESSIBLE ON

ONE SIDE ONLY (VARIABLE DIAMETER)

ALSO AVAILABLE: FULL THUMBWHEEL OPERATOR

ACCESSIBLE ON BOTH SIDES

CLEARANCE

REQUIRED

VISION CONTROL

®

PANEL

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

HOLLOW METAL

FRAME BY OTHERS

OUTSIDE & INSIDE

0.080" (2mm)

THICK BREAK METAL

CLOSURE BY UNICEL

GLAZING TAPE

BY OTHERS

3M TAPE 1/16" (1.6mm)

TYPICAL

BY OTHERS

VIEW

90° ANGLE

FINITIONS STANDARD* BREAK METALGLASS STOPS

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

LOUVERS

* OTHER FINISHES AVAILABLE UPON REQUEST.

AutoCAD SHX Text
R
Page 17: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.7

2020

VISION CONTROL

®

INTERIOR WALL

CORNER CONFIGURATIONS

INTERIOR

DETAIL

BUTT-GLAZED WITH CORNER BRAKE METAL

B

19

.1

mm

3/4

''

19

.1

mm

3/4

''

63

.5

mm

2 1

/2

''

19.1mm

3/4''

19.1mm

3/4''

63.5mm

2 1/2''

9

0

°

12.7mm

1/2''

28

.6

mm

1 1

/8

''

9.5mm

3/8''

9.5

mm

3/8

''

19

.1

mm

3/4

''

19

.1

mm

3/4

''

63

.5

mm

2 1

/2

''

9.5

mm

3/8

''

28

.6

mm

1 1

/8

''

INTERIOR

DETAIL

BUTT-GLAZED WITHOUT CORNER BRAKE METAL

VIEW

VISION CONTROL

®

PANEL

HOLLOW METAL

FRAME BY OTHERS

GLAZING TAPE

BY OTHERS

FOLDABLE ZINC

CRANK HANDLE

(OPTIONAL)

GEAR HOUSING

FOLDABLE ZINC CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

CERAMIC FRIT ON

INSIDE FACE OF GLASS

(COLOR TO BE DETERMINED)

SILICONE JOINTS ON

CORNER GLASS

BY OTHERS

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

CLEARANCE

REQUIRED

9

0

°

C

VISION CONTROL

®

PANEL

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

GLAZING TAPE

BY OTHERS

CLEARANCE

REQUIRED

HOLLOW METAL

FRAME BY OTHERS

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

HOLLOW METAL

FRAME BY OTHERS

FULL THUMBWHEEL

OPERATOR ACCESSIBLE ON BOTH SIDES

(VARIABLE DIAMETER)

ALSO AVAILABLE: FAN-SHAPED THUMBWHEEL

OPERATOR ACCESSIBLE ON ONE SIDE

19.1mm

3/4''

19.1mm

3/4''

63.5mm

2 1/2''

ROUNDED ALUMINUM

EXTENSION BLOCK

AutoCAD SHX Text
R
Page 18: VISION CONTROL FEATURES R - Unicel

C

B

A

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.8

9.5mm

3/8''

A

9.5mm

3/8''

9.5

mm

3/8

''

19

.1

mm

3/4

''

19

.1

mm

3/4

''

63

.5

mm

2 1

/2

''

2

8

.

6

m

m

1

1

/

8

'

'

2020

VISION CONTROL

®

INTERIOR WALL

CORNER CONFIGURATIONS

VARIES

VARIES

V

A

R

I

E

S

V

A

R

I

E

S

V

A

R

I

E

S

HOLLOW METAL

FRAME BY OTHERS

OUTSIDE & INSIDE 0.080" (2mm)

THICK BREAK METAL CLOSURE

BY UNICEL

RIGID INSULATOR

(IF REQUIRED)

BY OTHERS

3M TAPE 1/16" (1.6mm) TYPICAL

BY OTHERS

VISION CONTROL

®

PANEL

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

GLAZING TAPE

BY OTHERS

FAN-SHAPED THUMBWHEEL OPERATOR

ACCESSIBLE ON ONE SIDE ONLY

(VARIABLE DIAMETER)

ALSO AVAILABLE: FULL THUMBWHEEL

OPERATOR ACCESSIBLE ON BOTH SIDES

VIEW

INTERIOR

DETAIL

BUTT-GLAZED WITH CORNER BRAKE METAL

CLEARANCE

REQUIRED

VARIABLE ANGLE

FINITIONS STANDARD* BREAK METALGLASS STOPS

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

LOUVERS

* OTHER FINISHES AVAILABLE UPON REQUEST.

AutoCAD SHX Text
R
Page 19: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.1.9

1

2

.

7

m

m

1

/

2

'

'

12.7mm

1/2''

9.5mm

3/8''

9.5

mm

3/8

''

B

C

19

.1

mm

3/4

''

19

.1

mm

3/4

''

63

.5

mm

2 1

/2

''

19

.1

mm

3/4

''

19

.1

mm

3/4

''

63

.5

mm

2 1

/2

''

2

8

.

6

m

m

1

1

/

8

'

'

2

8

.

6

m

m

1

1

/

8

'

'

9.5

mm

3/8

''

2020

VISION CONTROL

®

INTERIOR WALL

CORNER CONFIGURATIONS

V

A

R

I

E

S

HOLLOW METAL FRAME

BY OTHERS

VISION CONTROL

®

PANEL

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

GLAZING TAPE

BY OTHERSCERAMIC FRIT ON

INSIDE FACE OF GLASS

(COLOR TO BE DETERMINED)

SILICONE JOINTS ON

CORNER GLASS

BY OTHERS

HOLLOW METAL FRAME

BY OTHERS

HOLLOW METAL FRAME

BY OTHERS

VISION CONTROL

®

PANEL

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

GLAZING TAPE

BY OTHERS

FULL THUMBWHEEL

OPERATOR ACCESSIBLE ON BOTH SIDES

(VARIABLE DIAMETER)

ALSO AVAILABLE: FAN-SHAPED THUMBWHEEL

OPERATOR ACCESSIBLE ON ONE SIDE

VIEW

VIEW

INTERIOR

DETAIL

INTERIOR

DETAIL

CLEARANCE

REQUIRED

CORNER POST

BUTT-GLAZED WITHOUT CORNER BRAKE METAL

GEAR HOUSING

CLEARANCE

REQUIRED

FOLDABLE ZINC

CRANK HANDLE

(OPTIONAL)

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

V

A

R

I

E

S

ROUNDED ALUMINUM

EXTENSION BLOCK

AutoCAD SHX Text
R
Page 20: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.2.1

B

A

B

A

12.7m

m

1/2''

161.8m

m

6 3/8''

50.8mm

2''

1.6mm

1/16''

2.8mm

1/8''

15.7m

m

5/8''

161.8m

m

6 3/8''

50.8mm

2''

28.6m

m

1 1/8''

33.4m

m

1 5/16''

2020

50.8m

m

2''

VISION CONTROL

®

EXTERIOR WALL

VARIOUS FRAMES

EXTERIOR

DETAIL

EXTERIOR

DETAIL

OVAL PLATE

VISION CONTROL

®

PANEL

ALUMINUM FRAME

BY OTHERS

SETTING BLOCK

FLYSCREEN

ALUMINUM WINDOW FRAME

OPENING INWARDS

BY UNICEL

VISION CONTROL

®

PANEL

SETTING BLOCK

OPERABLE WINDOW

STOREFRONT SYSTEM

UNIVERSAL

L-ANGLE TRIM

BY UNICEL

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

PRESSURE PLATES AND

SNAP-ON COVERS BY UNICEL

ROUNDED ALUMINUM

EXTENSION BLOCK

AutoCAD SHX Text
R
Page 21: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.2.2

28

.6

mm

1 1

/8

''

50.8mm

2''

19.1mm

3/4''

16

1.9

mm

6 3

/8

''

C

E

C D

25

.4

mm

1''

16

1.9

mm

6 3

/8

''

50.8mm

2''

6mm

1/4''

6mm

1/4''

E

6mm

1/4''

19.1mm

3/4''

28

.6

mm

1 1

/8

''

9.5mm

3/8''

63.5mm

2 1/2''

3.2mm

1/8''

18

7.3

mm

7 3

/8

"

12

.7

mm

1/2

''

63

.5

mm

2 1

/2

''

D

50.8m

m

2''

105.5mm

4 5/32''

25.4mm

1''

3.2

mm

1/8

''

50

.8

mm

2''

25.4mm

1''

2020

EXTERIOR

DETAIL

VISION CONTROL

®

EXTERIOR WALL

VARIOUS FRAMES

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

VISION CONTROL

®

PANEL

EXTERIOR

DETAIL

FAN-SHAPED

THUMBWHEEL OPERATOR

(VARIABLE DIAMETER)

VISION CONTROL

®

PANEL

BRASS LIGATURE-RESISTANT KNOB

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

1/4" (6mm) CLEAR

POLYCARBONATE

1/4" (6mm) CLEAR

TEMPERED GLASS

1/4" (6mm) CLEAR

TEMPERED GLASS WITH

SOFT-COAT LOW-E #2

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

CURTAIN WALL SYSTEMS

BY UNICEL OR BY OTHERS

SETTING BLOCKS

BY OTHERS

GEAR HOUSING

EXTERIOR

DETAIL

EXISTING CURTAIN WALL SYSTEM CURTAIN WALL ADAPTER

OFFSET TRIPLE GLAZED

OVAL

PLATE

SETTING BLOCK

BY OTHERS

CURTAIN WALL

SYSTEMS BY

UNICEL OR

BY OTHERS

CURTAIN WALL SYSTEMS

BY UNICEL OR BY OTHERS

CURTAIN WALL ADAPTER

(FACTORY-GLAZED)

FOLDABLE ZINC

CRANK HANDLE

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

± 115°

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME DOWN

FROM OPERABLE SIDE

ROUNDED ALUMINUM

EXTENSION BLOCK

ROUNDED ALUMINUM

EXTENSION BLOCK

AutoCAD SHX Text
R
Page 22: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 2.2.3

2020

F

25.4mm

1''

82.5mm

3 1/4''

6.4mm

1/4''

45.3mm

1 25/32''

16

1.9

mm

6 3

/8

''

44

.4

mm

1 3

/4

''

6.4

mm

1/4

''

6.3mm

1/4''

25.4mm

1''

6.4mm

1/4''

7.7mm

5/16''

F

G

16

1.9

mm

6 3

/8

''

63.5mm

2 1/2''

6mm

1/4''

12.5mm

1/2''

G

VISION CONTROL

®

EXTERIOR WALL

BEHAVIORAL / MENTAL

HEALTH APPLICATION

BEHAVIORAL HEALTH - EXTERIOR WINDOW

BEHAVIORAL HEALTH - INTERIOR WINDOW

EXTERIOR

DETAIL

SETTING BLOCK BY OTHERS

NORTON TAPE THERMALBOND

2X 1/4" X 1/4" BY UNICEL

STRUCTURAL SILICONE JOINT

GEAR HOUSING

1/2" (12.5mm) CLEAR POLYCARBONATE

1/4" (6mm) CLEAR TEMPERED GLASS

BRASS LIGATURE-RESISTANT KNOB

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

VISION CONTROL

®

PANEL

SILICONE SEALANT

EXTERIOR

DETAIL

BRASS LIGATURE-RESISTANT KNOB

(REFER TO PAGE VC 1.2.1

FOR OPTIONAL OPERATORS)

1/2" (12.5mm) CLEAR POLYCARBONATE

(SCRATCH-RESISTANT RECOMMENDED)

1/4" (6mm) CLEAR TEMPERED GLASS

STRUCTURAL SILICONE JOINT

VISION CONTROL

®

PANEL

GEAR HOUSING

ALUMINUM SUPPORT

FOR SETTING BLOCK

(WELDED EXTENSION)

SETTING BLOCK

20

.6

mm

13

/1

6''

UNICEL'S CURTAIN WALL (CW) SYSTEM

- SEE SECTION CURTAIN WALL (CW) OF

UNICEL'S CORPORATE CATALOG

WELDED PERIMETER

ALUMINUM ANGLE 2"X2"X1/4"

STRUCTURAL SILICONE JOINT

ALUMINUM SNAP-ON

GLASS STOPS BY UNICEL

AAMA 501.8-TESTED FOR

2000 FT-LB HUMAN IMPACTS

AAMA 501.8-TESTED FOR

2000 FT-LB HUMAN IMPACTS

WOOD BLOCKING

4 in.

(101.6mm)

WIDTH

HEIGHT

MINIMUM

65 3/8 in.

(1660.5mm)

75 3/8 in.

(1914.5mm)

MAXIMUM

4 in.

(101.6mm)

4 in.

(101.6mm)

WIDTH

HEIGHT

MINIMUM

52 1/2 in.

(1333.5mm)

74 5/16 in.

(1887.5mm)

MAXIMUM

4 in.

(101.6mm)

STEEL STUD MINIMUM 18 GA.

SHIM BY OTHERS

ALUMINUM FRAME 1 3/4" X 5"

OR 6" BY UNICEL

AutoCAD SHX Text
R
Page 23: VISION CONTROL FEATURES R - Unicel

VC 3.1.1

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

C

B

A

12

.7

mm

1/2

''

15

.9

mm

5/8

''

58

.7

mm

2 5

/1

6''

12

.7

mm

1/2

''

42

.9

mm

1 1

1/1

6''

58

.7

mm

2 5

/1

6''

50.8mm

2''

82.6mm

3 1/4''

44.5mm

1 3/4''

12

.7

mm

1/2

''

A

C

9.5mm

3/8''

27mm

1 1/16''

B

82

.6

mm

3 1

/4

''

63

.5

mm

2 1

/2

''

2020

VISION CONTROL

®

DOOR CONFIGURATION

CRANK HANDLE OPERABLE ON ONE OR BOTH SIDE(S)

VISION CONTROL

®

FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS

VISION CONTROL

®

PANEL

OVAL PLATE

SETTING BLOCK

BY UNICEL

VA

RIE

S

FOLDABLE ZINC

CRANK HANDLE

DOOR BY OTHERS

COEX GLAZING

SNAP-ON TRIM

SETTING BLOCK

BY UNICEL

GEAR HOUSING

VISION CONTROL

®

PANEL

FOLDABLE ZINC

CRANK HANDLE

(OPTIONAL)

VA

RIE

S

GEAR HOUSING

DOOR

BY OTHERS

COEX GLAZING

SNAP-ON TRIM

FOLDABLE ZINC

CRANK HANDLE

(OPTIONAL)

FOLDABLE ZINC

CRANK HANDLE

OVAL PLATE

(N

ON

-S

TA

ND

AR

D L

OC

AT

IO

N

FO

R O

PE

RA

TO

RS

A

VA

IL

AB

LE

)

FOLDABLE ZINC

CRANK HANDLE

(WHITE OR GRAY)

OVAL

PLATE

STANDARD FINISHES*

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

LOUVERS DOOR TRIMS

* OTHER FINISHES AVAILABLE UPON REQUEST.

SETTING BLOCK

BY OTHERS

OPTIONAL OPERATORS:

31/32'' (24.6mm) Ø

BRASS LIGATURE-RESISTANT KNOB

(PAINTED WHITE OR GRAY)

1" (25.4mm) Ø

ALUMINUM KNOB

- WHITE K-1285

- GRAY K-20794

- CUSTOM COLORS

AutoCAD SHX Text
R
Page 24: VISION CONTROL FEATURES R - Unicel

VC 3.1.2

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

C

B

A

12.7m

m

1/2''

15.9m

m

5/8''

58.7m

m

2 5/16''

12.7m

m

1/2''

187.3m

m

7 3/8''

A76.2m

m

3''

9.5mm

3/8''

9.5mm

3/8''

27mm

1 1/16''

82.6m

m

3 1/4''

50.8m

m

2''

B

9.5m

m

3/8''

9.5m

m

3/8''

42.9m

m

1 11/16''

58.7m

m

2 5/16''

50.8mm

2''

82.6mm

3 1/4''

44.5mm

1 3/4''

187.3m

m

7 3/8''

12.7m

m

1/2''

C

9.5mm

3/8''

2020

9.5mm

3/8''

VISION CONTROL

®

DOOR CONFIGURATION

STANDARD FINISHES*

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

LOUVERS DOOR TRIMS

* OTHER FINISHES AVAILABLE UPON REQUEST.

THUMBWHEEL OPERABLE ON BOTH SIDES

VISION CONTROL

®

FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS

THUMBWHEEL

OPERATOR

DOOR

BY OTHERS

DOOR BY OTHERS

COEX GLAZING

SNAP-ON TRIM

SETTING BLOCK

BY UNICEL

VISION CONTROL

®

PANEL

CUT-OUT

COEX GLAZING

SNAP-ON TRIM

SETTING BLOCK

BY UNICEL

VISION CONTROL

®

PANEL

SETTING BLOCK

BY OTHERS

FULL THUMBWHEEL

OPERATOR

- WHITE ALUMINUM

- GRAY ALUMINUM

- BLACK POLYMER

FULL THUMBWHEEL

OPERATOR

- WHITE ALUMINUM

- GRAY ALUMINUM

- BLACK POLYMER

AutoCAD SHX Text
R
Page 25: VISION CONTROL FEATURES R - Unicel

VC 3.1.3

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

A

B

C

82

.6

mm

3 1

/4

''

50

.8

mm

2''

B

42

.9

mm

1 1

1/1

6''

58

.7

mm

2 5

/1

6''

50.8mm

2''

82.6mm

3 1/4''

44.5mm

1 3/4''

18

7.3

mm

12

.7

mm

1/2

''

A

9.5mm

3/8''

7 3

/8

"

A

12

.7

mm

1/2

''

58

.7

mm

2 5

/1

6''

12

.7

mm

1/2

''

18

7.3

mm

C

7 3

/8

"

76

.2

mm

3''

9.5mm

3/8''

9.5mm

3/8''

27mm

1 1/16''

9.5

mm

3/8

''

9.5mm

3/8''

2020

VISION CONTROL

®

DOOR CONFIGURATION

STANDARD FINISHES*

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

LOUVERS DOOR TRIMS

* OTHER FINISHES AVAILABLE UPON REQUEST.

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE

VISION CONTROL

®

FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS

DOOR

BY OTHERS

DOOR BY OTHERS

COEX GLAZING

SNAP-ON TRIM

SETTING BLOCK

BY UNICEL

VISION CONTROL

®

PANEL

CLOSED OPEN

VISION CONTROL

®

PANEL

SETTING BLOCK

BY UNICEL

FAN-SHAPED

THUMBWHEEL OPERATOR

CUT-OUT

COEX GLAZING

SNAP-ON TRIM

SETTING BLOCK

BY OTHERS

± 115°

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME DOWN

FROM OPERABLE SIDE

FAN-SHAPED

THUMBWHEEL

OPERATOR

- WHITE ALUMINUM

- GRAY ALUMINUM

- BLACK POLYMER

FAN-SHAPED

THUMBWHEEL

OPERATOR

- WHITE ALUMINUM

- GRAY ALUMINUM

- BLACK POLYMER

AutoCAD SHX Text
R
Page 26: VISION CONTROL FEATURES R - Unicel

VC 3.2

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

A

50.8mm

2''

A

B

1.6mm

1/16''

12.7mm

1/2''

1.6mm

1/16''

12.7mm

1/2''

B

1.6mm

1/16''

12.7mm

1/2''

1.6mm

1/16''

12.7mm

1/2''

D

C D

50.8mm

2''

187.3m

m

7 3/8''

C

9.5mm

3/8''

50.8mm

2''

1.6mm

1/16''

3.2mm

1/8''

1.6mm

1/16''

3.2mm

1/8''

161.9m

m

6 3/8''

12.7m

m

1/2''

12.7m

m

1/2''

12.7m

m

1/2''

161.9m

m

6 3/8''

12.7m

m

1/2''

2020

50.8mm

2''

1.6mm

1/16''

12.7mm

1/2''

1.6mm

1/16''

12.7mm

1/2''

9.5mm

3/8''

9.5mm

3/8''

44.5mm

1 3/4''

44.5mm

1 3/4''

44.5mm

1 3/4''

44.5mm

1 3/4''

28.6m

m

1 1/8''

28.6m

m

1 1/8''

28.5m

m

1 1/8''

28.5m

m

1 1/8''

187.3m

m

7 3/8''

GEAR HOUSING

VISION CONTROL

®

PANEL

FOLDABLE ZINC

CRANK HANDLE

FOLDABLE ZINC

CRANK HANDLE

(OPTIONAL)

DETAIL

SUGGESTED CUSTOM DOOR TRIMS BY OTHERS

VISION CONTROL

®

PANEL

DETAIL

DETAIL

FULL THUMBWHEEL

OPERABLE ON

BOTH SIDES

VISION CONTROL

®

PANEL

DETAIL

FAN-SHAPED

THUMBWHEEL

OPERABLE

ON ONE SIDE ONLY

VISION CONTROL

®

PANEL

CU

T-O

UT

CU

T-O

UT

CUT-OUT

BY OTHERS

CUT-OUT

BY OTHERS

GLAZING TAPE

BY OTHERS

GLAZING TAPE

BY OTHERS

GLAZING TAPE

BY OTHERS

FOLDABLE ZINC

CRANK HANDLE

FOLDABLE ZINC

CRANK HANDLE

(OPTIONAL)

GEAR HOUSING

VISION CONTROL

®

DOOR CONFIGURATION

± 115°

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME DOWN

FROM OPERABLE SIDE

GLAZING TAPE

BY OTHERS

DOOR BY OTHERS

WOOD TRIM

BY OTHERS

SETTING BLOCK

BY OTHERS

DOOR BY OTHERS

STEEL TRIM

BY OTHERS

SETTING BLOCK

BY OTHERS

DOOR BY OTHERS

WOOD TRIM

BY OTHERS

SETTING BLOCK

BY OTHERS

DOOR BY OTHERS

STEEL TRIM

BY OTHERS

SETTING BLOCK

BY OTHERS

OPTIONAL OPERATORS:OPTIONAL OPERATORS:

31/32'' (24.6mm) Ø

BRASS LIGATURE-RESISTANT KNOB

(PAINTED WHITE OR GRAY)

3/4" (19.1mm) Ø

ALUMINUM KNOB

31/32'' (24.6mm) Ø

BRASS LIGATURE-RESISTANT KNOB

(PAINTED WHITE OR GRAY)

3/4" (19.1mm) Ø

ALUMINUM KNOB

AutoCAD SHX Text
R
Page 27: VISION CONTROL FEATURES R - Unicel

VC 4.1.1

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

2020

CARACTÉRISTIQUES DU MOTEUR:

5

6

4

1

3

2

7

1- WORM GEAR SHAFT

2- GEARING WHEEL

3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)

4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)

5- FLEXIBLE CABLE

6- SOMFY

®

MOTOR

7- VISION CONTROL

®

PANEL

MOTOR TYPE TO BE DETERMINED BY

UNICEL'S ENGINEERING DEPARTMENT

NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION

SOMFY

®

MOTOR

VISION CONTROL

®

MOTORIZATION

- MODEL: SOMFY

®

- APPROX. DIM.: 29/32" x 1 7/32"

(23.1mm x 31.2mm)

- AMP: 1.2

- VOLTS: 12 DC

- RPM: 68

- RTS: 433.42 MHZ

AutoCAD SHX Text
R
Page 28: VISION CONTROL FEATURES R - Unicel

VC 4.1.2

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

28.6mm

1 1/8"

2020

2

1

4

3

CLEARANCE

(TYPICAL)

VISION CONTROL

®

GROUPED MOTORIZATION

SOMFY

®

MOTOR

UNLIMITED NUMBER OF VISION CONTROL

®

PANELS (ONE MOTOR PER UNIT)

1- SOMFY

®

MOTOR

2- GEAR HOUSING 2 1/8" x 2 9/32"

(54mm x 57.9mm)

3- FLEXIBLE CABLE

4- VISION CONTROL

®

PANEL

VISION CONTROL

®

PANEL

WIRING DIAGRAM FOR 12 VOLT DC MOTOR

- MODEL: SOMFY

®

- APPROX. DIM.: 29/32" x 1 7/32"

(23.1mm x 31.2mm)

- AMP: 1.2

- VOLTS: 12 DC

- RPM: 68

- RTS: 433.42 MHZ

MOTOR SPECIFICATIONS:

12 VOLT

POWER SUPPLY

120 - 220 V/AC

MOTOR

AutoCAD SHX Text
R
Page 29: VISION CONTROL FEATURES R - Unicel

VC 4.1.3

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

2020

B

B

50.8mm

2''

187.3m

m

127mm OR 152.4mm

5" OR 6"

25.4m

m

1''

44.5m

m

1 3/4''

44.4m

m

1 3/4''

6.4m

m

1/4''

25.4mm

1''

7 3/8"

57.9mm

2 9/32''

54m

m

2 1/8''

57.9mm

2 9/32''

A

101.6m

m

4''

A

28.6mm

1 1/8''

44.5mm

1 3/4''

44.4mm

1 3/4''

23.1mm

29/32''

31.2m

m

1 7/32''

50.8m

m

2''

25.4m

m

1''

5" O

R 6"

SOMFY

®

MOTOR

VISION CONTROL

®

MOTORIZATION

INTERIOR

DETAIL

SOMFY

®

MOTOR

SETTING BLOCK

BY OTHERS

VISION CONTROL

®

PANEL

ALUMINUM FRAME &

GLASS STOPS

BY UNICEL

GEAR HOUSING

VA

RIE

S

INTERIOR

DETAIL

SOMFY

®

MOTOR

GEAR HOUSING

VISION CONTROL

®

PANEL

ALUMINUM FRAME &

GLASS STOPS

BY UNICEL

127m

m O

R 152.4m

m

- MODEL: SOMFY

®

- APPROX. DIM.: 29/32" x 1 7/32"

(23.1mm x 31.2mm)

- AMP: 1.2

- VOLTS: 12 DC

- RPM: 68

- RTS: 433.42 MHZ

MOTOR SPECIFICATIONS:

FLEXIBLE CABLE

AutoCAD SHX Text
R
Page 30: VISION CONTROL FEATURES R - Unicel

VC 4.2.1

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

2020

4

3

9

2

1

5

8

10

6

7

10

1- WORM GEAR SHAFT

2- GEARING WHEEL

3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)

4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)

5- FLEXIBLE CABLE

6- CORNER DRIVE

7- BALDOR MOTOR

8- RIGID SHAFT 5/8" Ø (15.9mm)

9- VISION CONTROL

®

PANEL

10- SET SCREW #10-24 x 3/16" (4.8mm)

MOTOR TYPE TO BE DETERMINED BY

UNICEL'S ENGINEERING DEPARTMENT

NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION

BALDOR MOTOR

VISION CONTROL

®

MOTORIZATION

- MODEL: BALDOR

- APPROX. DIM.: 3 3/4" x 8 1/8"

(95.3mm x 206.4mm)

- AMP: 1

- VOLTS: 120 AC

- RPM: 163

- HZ: 60

- PHASE: 1

- TORQUE 28.5 IN-LB

MOTOR SPECIFICATIONS:

AutoCAD SHX Text
R
Page 31: VISION CONTROL FEATURES R - Unicel

5

4

1

7

2

3

3

6

VC 4.2.2

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

12.7mm

1/2"

8

FIL

#5NC

NO

C#5

#1

#0

#0NC

NO

C

CAM

2020

CLEARANCE

(TYPICAL)

VISION CONTROL

®

GROUPED MOTORIZATION

(WITH LIMIT SWITCH)

BALDOR MOTOR

MAXIMUM OF 12 VISION CONTROL

®

PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)

1- BALDOR MOTOR

2- CORNER DRIVE

3- GEAR HOUSING 2 1/8" x 2 9/32"

(54mm x 57.9mm)

4- FLEXIBLE CABLE

5- RIGID SHAFT 5/8" Ø (15.9mm)

6- VISION CONTROL

®

PANEL

7- JUNCTION BOX

8- LIMIT SWITCH

VISION CONTROL

®

PANEL

WIRING DIAGRAM FOR 120 VOLT AC MOTOR WITH LIMIT SWITCH

ELECTRICAL DIAGRAM

NOTES:

1- SWITCH SPDT SHOWN FOR ILLUSTRATION ONLY

2- LIMIT SWITCH SHOWN IN CLOSED POSITION

3- POWER TO THE #5 WIRE OPERATES UNIT INTO CLOSED POSITION

4- POWER TO THE #0 WIRE OPERATES UNIT INTO CLOSED POSITION

- MODEL: BALDOR

- APPROX. DIM.: 3 3/4" x 8 1/8"

(95.3mm x 206.4mm)

- AMP: 1

- VOLTS: 120 AC

- RPM: 163

- HZ: 60

- PHASE: 1

- TORQUE 28.5 IN-LB

MOTOR SPECIFICATIONS:

LIMIT SWITCH

JUNCTION BOX

ELECTRIC BOX FOR SWITCH

(MUST BE INSTALLED

IN A LOCATION PERMITTING

VISUAL CONTROL)

120 - 220 V-AC

CAPACITOR

MOTOR

LIMIT

SWITCH

AC LINE

120 VOLTS

MOTOR

SPDT

SWITCH

AutoCAD SHX Text
R
Page 32: VISION CONTROL FEATURES R - Unicel

5

VC 4.2.3

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

3

6

2

4

7

3

#1

#5

#0

1

2020

12.7mm

1/2"

VISION CONTROL

®

GROUPED MOTORIZATION

(WITHOUT LIMIT SWITCH)

BALDOR MOTOR

MAXIMUM OF 12 VISION CONTROL

®

PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)

1- BALDOR MOTOR

2- CORNER DRIVE

3- GEAR HOUSING 2 1/8" x 2 9/32"

(54mm x 57.9mm)

4- FLEXIBLE CABLE

5- RIGID SHAFT 5/8" Ø (15.9mm)

6- VISION CONTROL

®

PANEL

7- JUNCTION BOX

VISION CONTROL

®

PANEL

WIRING DIAGRAM FOR 120 VOLT AC MOTOR WITHOUT LIMIT SWITCH

- MODEL: BALDOR

- APPROX. DIM.: 3 3/4" x 8 1/8"

(95.3mm x 206.4mm)

- AMP: 1

- VOLTS: 120 AC

- RPM: 163

- HZ: 60

- PHASE: 1

- TORQUE 28.5 IN-LB

MOTOR SPECIFICATIONS:

JUNCTION BOX

WIRE

ELECTRIC BOX FOR SWITCH

(MUST BE INSTALLED

IN A LOCATION PERMITTING

VISUAL CONTROL)

120 - 220 V-AC

MOTOR

ELECTRICAL DIAGRAM

MOTOR

CAPACITOR

GREEN - YELLOW

NEUTRAL

120 VOLTS AC

SWITCH

CLEARANCE

(TYPICAL)

AutoCAD SHX Text
R
Page 33: VISION CONTROL FEATURES R - Unicel

MIN

IM

UM

8

" (2

03

.2

m

m)

19mm

3/4''

28

.6

mm

1 1

/8

''

19.1mm

3/4''

28

.6

mm

1 1

/8

''

63

.5

mm

2 1

/2

''

18

7.3

mm

63

.5

mm

2 1

/2

''

8.9

mm

11

/3

2''

88.9mm

3 1/2''

21.1mm

27/32''

B

50.8mm

2''

18

7.3

m

m

12

.7

mm

1/2

''

50.8mm

2''

63

.5

mm

2 1

/2

''

9.5

mm

3/8

''

VC 4.2.4

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

A

7 3

/8

"

7 3

/8

"

A

B

2020

54

mm

2 1

/8

''

57.9mm

2 9/32''

54

mm

2 1

/8

''

57.9mm

2 9/32''

12

.7

mm

1/2

''

50

.8

mm

2''

VA

RIE

S

THERMALLY BROKEN

ALUMINUM FRAME

DETAIL

INTERIOR WALL

DETAIL

EXTERIOR WALL

VISION CONTROL

®

PANEL

BALDOR MOTOR

CORNER DRIVE

ALUMINUM

TRACK

LAY-IN CEILING

FLEXIBLE CABLE

GEAR HOUSING

LIMIT SWITCH

BALDOR MOTOR

CORNER DRIVE

FLEXIBLE CABLE

GEAR HOUSING

VISION CONTROL

®

PANEL

- MODEL: BALDOR

- APPROX. DIM.: 3 3/4" x 8 1/8"

(95.3mm x 206.4mm)

- AMP: 1

- VOLTS: 120 AC

- RPM: 163

- HZ: 60

- PHASE: 1

- TORQUE 28.5 IN-LB

MOTOR SPECIFICATIONS:

VISION CONTROL

®

MOTORIZATION

BALDOR MOTOR

(SUGGESTED DETAIL)

WITHOUT LIMIT SWITCH WITH LIMIT SWITCH

AutoCAD SHX Text
R
Page 34: VISION CONTROL FEATURES R - Unicel

5

VC 4.3.1

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

2020

3

2

4

1

9

10

6

7

8

10

MOTOR TYPE TO BE DETERMINED BY

UNICEL'S ENGINEERING DEPARTMENT

NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION

PITTMAN MOTOR

VISION CONTROL

®

MOTORIZATION

- MODEL: PITTMAN

- APPROX. DIM.: 2" x 3 5/8"

(50.8mm x 92.1mm)

- AMP: 0.6

- VOLTS: 24 DC

- RPM: 160

MOTOR SPECIFICATIONS:

1- WORM GEAR SHAFT

2- GEARING WHEEL

3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)

4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)

5- FLEXIBLE CABLE

6- CORNER DRIVE

7- PITTMAN MOTOR

8- RIGID SHAFT 5/8" Ø (15.9mm)

9- VISION CONTROL

®

PANEL

10- SET SCREW #10-24 x 3/16" (4.8mm)

AutoCAD SHX Text
R
Page 35: VISION CONTROL FEATURES R - Unicel

SEE VC 4.3.4

VC 4.3.2

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

1 2

3

4

6

7 8

A

5

#5

#0

#1

24 VDC

2020

VISION CONTROL

®

MOTORIZATION

(WITH LIMIT SWITCH)

1- PITTMAN MOTOR

2- CORNER DRIVE

3- GEAR HOUSING 2 1/8" x 2 9/32"

(54mm x 57.9mm)

4- FLEXIBLE CABLE

5- RIGID SHAFT 5/8" Ø (15.9mm)

6- VISION CONTROL

®

PANEL

7- JUNCTION BOX

8- LIMIT SWITCH

VISION CONTROL

®

PANEL

WIRING DIAGRAM FOR 24 VDC MOTOR WITH LIMIT SWITCH

LIMIT SWITCH

JUNCTION BOX

WIRE

24 VDC POWER SUPPLY

120 - 220 V-AC

MOTOR

WIRE

STANDARD ELECTRIC BOX

FOR DPDT SWITCH

LIMIT

SWITCH

LIMIT

SWITCH

RED

BLACK

RED

BLACK

MOTOR

ELECTRICAL DIAGRAM

DPDT MAINTAIN OR

MOMENTARY SWITCH

PITTMAN MOTOR

MAXIMUM OF 4 VISION CONTROL

®

PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)

- MODEL: PITTMAN

- APPROX. DIM.: 2" x 3 5/8"

(50.8mm x 92.1mm)

- AMP: 0.6

- VOLTS: 24 DC

- RPM: 160

MOTOR SPECIFICATIONS:

AutoCAD SHX Text
+
AutoCAD SHX Text
-
AutoCAD SHX Text
R
Page 36: VISION CONTROL FEATURES R - Unicel

VC 4.3.3

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

12

3

4

7

6

B

5

FIL

FIL

24 VDC

2020

VISION CONTROL

®

MOTORIZATION

(WITHOUT LIMIT SWITCH)

SEE VC 4.3.4

1- PITTMAN MOTOR

2- CORNER DRIVE

3- GEAR HOUSING 2 1/8" x 2 9/32"

(54mm x 57.9mm)

4- FLEXIBLE CABLE

5- RIGID SHAFT 5/8" Ø (15.9mm)

6- VISION CONTROL

®

PANEL

7- JUNCTION BOX

VISION CONTROL

®

PANEL

WIRING DIAGRAM FOR 24 VDC MOTOR WITHOUT LIMIT SWITCH

JUNCTION BOX

24 VDC POWER SUPPLY

LOCATE THIS SUPPLY NEAR

YOUR ELECTRICAL PANEL

120 - 220 V-AC

MOTOR

STANDARD ELECTRIC BOX

FOR DPDT SWITCH

ELECTRICAL DIAGRAM

MOTOR

RED

BLACK

DPDT

MOMENTARY

SWITCH

RED

BLACK

PITTMAN MOTOR

MAXIMUM OF 4 VISION CONTROL

®

PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)

- MODEL: PITTMAN

- APPROX. DIM.: 2" x 3 5/8"

(50.8mm x 92.1mm)

- AMP: 0.6

- VOLTS: 24 DC

- RPM: 160

MOTOR SPECIFICATIONS:

AutoCAD SHX Text
R
AutoCAD SHX Text
+
AutoCAD SHX Text
-
Page 37: VISION CONTROL FEATURES R - Unicel

A

50

.8

mm

2''

28

.6

mm

1 1

/8

''

50

.8

mm

2''

50

.8

mm

2''

28

.6

mm

1 1

/8

''

18

7.3

mm

7 3

/8

''

12

.7

mm

1/2

''

50.8mm

2''

1.6mm

1/16''

1.6mm

1/16''

19.1mm

3/4''

19.1mm

3/4''

VC 4.3.4

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

B

50

.8

mm

2''

28

.6

mm

1 1

/8

''

50

.8

mm

2''

50

.8

mm

2''

28

.6

mm

1 1

/8

''

18

8.1

mm

7 1

3/3

2''

12

.7

mm

1/2

''

2020

19.1mm

3/4''

19.1mm

3/4''

50.8mm

2''

1.6mm

1/16''

1.6mm

1/16''

54

mm

2 1

/8

''

57.9mm

2 9/32''

54

mm

2 1

/8

''

57.9mm

2 9/32''

VA

RIE

S

INTERIOR WALL

DETAIL

VISION CONTROL

®

MOTORIZATION

PITTMAN MOTOR

(SUGGESTED DETAIL)

PITTMAN MOTOR

CORNER DRIVE

ALUMINUM

SUPPORT

ALUMINUM TRACK

LIMIT SWITCH

BOX

LAY-IN CEILING

BY OTHERS

FLEXIBLE CABLE

GEAR HOUSING

VA

RIE

S

INTERIOR WALL

DETAIL

PITTMAN MOTOR

CORNER DRIVE

ALUMINUM

SUPPORT

ALUMINUM TRACK

LAY-IN CEILING

BY OTHERS

FLEXIBLE CABLE

- MODEL: PITTMAN

- APPROX. DIM.: 2" x 3 5/8"

(50.8mm x 92.1mm)

- AMP: 0.6

- VOLTS: 24 DC

- RPM: 160

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

ALUMINUM SNAP-ON

GLASS STOPS

BY UNICEL

GEAR HOUSING

MOTOR SPECIFICATIONS:

VISION CONTROL

®

PANEL

VISION CONTROL

®

PANEL

WITH LIMIT SWITCH WITHOUT LIMIT SWITCH

AutoCAD SHX Text
R
Page 38: VISION CONTROL FEATURES R - Unicel

5

0

.

8

m

m

2

'

'

VC 5.1

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

2020

6

.

4

m

m

1

/

4

'

'

A

A

A

A

SKYLIGHT

VISION CONTROL

®

MOTORIZATION APPLICATION

VISION CONTROL

®

PANEL

FLEXIBLE CABLE

CORNER DRIVE

MOTOR

FLASHING

ALUMINUM PLATE

MEMBRANE

GEAR HOUSING

UNICEL'S SKYLIGHT FRAMING SYSTEM

- SEE SECTION SKYLIGHT (SK) OF

UNICEL'S CORPORATE CATALOG

DETAIL

EXTERIOR

AutoCAD SHX Text
R
Page 39: VISION CONTROL FEATURES R - Unicel

VC 5.2

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

2020

BOÎTE

D'ENGRENAGE

M

I

N

.

2

0

3

.

2

m

m

8

'

'

M

I

N

.

2

0

3

.

2

m

m

8

'

'

B

B

B

SOLARIUM

VISION CONTROL

®

MOTORIZATION APPLICATION

VISION CONTROL

®

PANEL

CRANK HANDLE

UNICEL'S SKYLIGHT (SK) SYSTEM

- SEE SECTION SKYLIGHT (SK) OF

UNICEL'S CORPORATE CATALOG

GEAR HOUSING

VISION CONTROL

®

PANEL

BALDOR MOTOR

PITTMAN MOTOR

DETAIL

EXTERIOR

DETAIL

EXTERIOR

FLEXIBLE CABLE

AutoCAD SHX Text
R
Page 40: VISION CONTROL FEATURES R - Unicel

VC 5.3

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

2020

4

8

6

3

9

6

8

7

4

5

2

5

2

1

VISION CONTROL

®

MOTORIZATION APPLICATION

SLOPED GLAZING

1- MOTOR

2- CORNER DRIVE

3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)

4- FLEXIBLE CABLE

5- RIGID SHAFT 5/8" Ø (15.9mm)

6- VISION CONTROL

®

PANEL

7- ALUMINUM SUPPORT

8- ALUMINUM STRUCTURE

9- SETTING BLOCK

AutoCAD SHX Text
R
Page 41: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 6.1

3

0

4

.

8

m

m

1

'-

0

''

30

4.8

mm

1'-0

''

2020

Storage Instructions

A. In Crates

Crates must be kept upright, covered, ventilated and in a dry and safe location.

B. Loose Lots

Sealed units must be upright, on blocks and in a safe and dry location. Sealed units should not be stored in

a stack, or in direct sunlight as heat build-up may cause breakage. Sealed units should have a base to

provide support to all component lites of the unit so that individual lites will not slide out of alignment or out

of square causing seal failure or breakage.

Handling Instructions

A. Extreme care must be taken when a unit is being moved. Edges and corners should be protected in order to

prevent glass from fracturing. The use of a corner protector is suggested.

FLOOR

WA

LL

CORRECT

METHOD

FLOOR

WA

LL

INCORRECT

METHOD

B. When moving Vision Control

® sealed glass panels, always do so as indicated below, flat or the gear

housing downwards.

VISION CONTROL

®

STORAGE & HANDLING

SEALED UNIT

CORNER PROTECTOR

WOOD BLOCKING

PLYWOOD

1/2" (12.7mm)

GEAR HOUSING

GEAR HOUSING

V

A

R

I

E

S

1

st

method : Flat 2

nd

method: Gear housing down

AutoCAD SHX Text
R
Page 42: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 6.2

2020

Frame/Sash

1. All framing members must be specifically designed to accept the glass specified and must have adequate structural

strength to support the weight of the glass without deformation.

2. Frame and/or sash must be level, plumb, square and in plane and also be free of any glazing obstruction.

3. Joints must be adequately buttered with sealant to prevent water and air infiltration and all sill members must have

weep holes to the outside.

Clearance and edge bite

1. Adequate edge and face clearances must be provided to allow the glass to float freely in the opening, without undue

restriction by the framing members. The recommended clearance on both vertical edges of the units is a minimum

of 3/8" (9.5mm) for thumbwheel-operated units, 1/2" (12.7mm) for units operated by crank handles, knobs or

Pittman and Baldor motors and 1 1/8" for Somfy motors.

2. Adequate bite is mandatory to maintain a watertight, weather-proof seal as well as retain the glass in the opening

under conditions of wind loading and deformation of the framing members.

Setting blocks

1. Neoprene setting blocks should be used on the bottom edge of each sealed unit. Place setting blocks at the end

points, under the metallic plates.

Sealing materials

1. For channel glazing, use only a non-hardening, non-corrosive, gun-applied sealant specifically recommended by the

sealant manufacturer for the type of glass specified

2. In no case shall glazing be performed with any oleo-resinous or oil-base compounds, nor shall any glazing sealant

be diluted or thinned with any solvent.

3. Never fill the space between the bottom edge of the glass and the sill. This will interfere with the weepage system.

4. All sealants must be applied to provide an absolute watertight seal; on insulating glass units, sealant must contact

the glass a minimum of 1/8” above the metal edge protection.

5. Sash with neoprene or structural neoprene gaskets must have a supplementary wet seal applied between the

gasket and the glass, at the bottom edge (sill) of the glass and 6” (152.4mm) up on each jamb. Sill section of all

structural neoprene gaskets must have weep holes to the exterior.

6. Special care must be taken when glazing laminated glass, polycarbonates and glass-clad polycarbonates, as they

may react unfavorably with certain sealant components. Sealants made of 100% solid components, containing no

solvents, must be used. Verify with your sealant manufacturer.

7. All surfaces to be sealed must be completely clean and dry. Verify with sealant manufacturer's recommendations for

proper cleaning procedures.

VISION CONTROL

®

INSTALLATION

GLAZING INSTRUCTIONS

AutoCAD SHX Text
R
Page 43: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 6.3

13

2020

5A

15

6

7A

8

15

9

3

2

4

1

7A

8

6

15

5A

15

7B

5B

12

10

11

5C

14

15

5C

5B

7B

15

14

6

6

CRANK HANDLE OR KNOB OPERATORS

VISION CONTROL

®

INSTALLATION

HOLE (SEE STEP D)

OPTION: DOUBLE

ALUMINUM KNOB

OPTION: DOUBLE ZINC

CRANK HANDLE

A. Install stainless steel worm gear shaft 1 into the cavity provided for it in the gear housing 3 . To insert the worm gear shaft in position, center it in the

gear housing and press firmly. Insert the white gearing wheel 2 on the brass shaft.

B. Make sure that the gear housing 3 is free of dirt. Screw the plastic cover 4 in place. Do not use excessive torque on screws in securing the plastic

cover.

C. (Skip this step if the operator is an ligature-resistant knob 5C ). Test the functionality of the units by temporarily installing the operator 5A or 5B and

tightening the set screw 15 . The mechanism is self-reversing and should be tested as follows: Turn the operator in one direction (e.g. clockwise).

When the louvers reach the closed position, continue turning 4-8 times in the same direction (e.g. clockwise) without fear of breaking the mechanism

until the louvers eventually re-open. Complete two full louver cycles by turning the operator in the same direction (e.g. clockwise). Repeat these steps

in the opposite direction (e.g. counter-clockwise) for two more full louver cycles.

D. Drill the following hole (behind the aluminum block 13 ) in glass stop at the appropriate position (for worm gear shaft 1 according to Unicel's approved

shop drawings): for the zinc crank handle 5A and the aluminum knob 5B , drill a 5/8" (15.9mm) diameter hole; for the ABS ligature-resistant knob 5C ,

drill a 3/8" (9.5mm) diameter hole.

E. Install setting blocks 12 under the metal plates glued to the unit. Make sure they are sufficiently rigid to secure glass panel into its permanent position.

F. Install the Vision Control

®

panel 9 in the opening which must be level, plumb, square and in plane. Make sure the shaft 1 is centered in the hole

drilled in step D.

G. If necessary, install aluminum supporting block 13 by securing with screws.

H. According to operator:

1. Zinc crank handle: Screw the oval plate 7A , the crank handle 5A and extension shaft 8 into the the frame with screws 6 .

Tighten the set screw 15 of the crank handle 5A if loose.

2. Aluminum knob: Screw the oval plate 7A , the knob 5B and extension shaft 8 into the the frame with screws 6 .

Tighten the set screw 15 of the knob 5B if loose.

3. Brass ligature-resistant knob: Assemble the extension shaft 8 with the round plate 7B and the brass adaptor 14 and tighten the first set screw.

Fix the assembly and the base of the knob 5C into the frame with screws 6 . Push the knob 5C into its base and tighten the second set screw 15 .

OPTION: REMOVABLE ZINC CRANK HANDLE

OPTION: DOUBLE BRASS

LIGATURE-RESISTANT

KNOB

1- WORM GEAR SHAFT

2- GEARING WHEEL

3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)

4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)

5A- ZINC CRANK HANDLE

5B- ALUMINUM KNOB

5C- BRASS LIGATURE-RESISTANT KNOB

6- SCREW #6 x 1/2" (12.7mm)

7A- OVAL PLATE

7B- ROUND PLATE

8- EXTENSION SHAFT

9- VISION CONTROL

®

PANEL

10- FRAME BY OTHERS

11- HEXAGONAL SOCKET

12- SETTING BLOCK

13- ALUMINUM BLOCK

14- BRASS ADAPTOR

15- SET SCREW

15

15

AutoCAD SHX Text
R
Page 44: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 6.4

2020

VISION CONTROL

®

INSTALLATION

FULL THUMBWHEEL OPERATOR

Install setting blocks under the metal plates glued to each unit. Make sure they are sufficiently rigid to secure the glass panels into their

permanent position. The units must be level, plumb, square and in plane. Install the glass stops, which should have been notched at

predetermined locations according to approved shop drawings, to accomodate thumbwheel operator.

ADDITIONAL INSTRUCTIONS

STEP 1 STEP 2

METAL PLATE

SETTING BLOCK

METAL PLATE

SETTING BLOCK

CIRCLIP

IMPORTANT NOTE:

Various thumbwheel diameters may occur throughout

this order. Please refer to approved shop drawings to

identify the proper thumbwheel diameter size to install.

This operation must be performed before installing

the sealed units in their respective openings.

Test the functionality of the units by turning the

thumbwheel in one direction (e.g. clockwise). When the

louvers reach the closed position, continue turning in

the same direction (e.g. clockwise) without fear of

breaking the mechanism until the louvers eventually

re-open. Complete two full louver cycles by turning the

operator, always in the same direction (e.g. clockwise).

Repeat these steps in the opposite direction (e.g.

counter-clockwise) for two more full louver cycles.

AutoCAD SHX Text
R
Page 45: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 6.5.1

2020

Install setting block under the metal plates glued to each unit. Make sure they are sufficiently rigid to secure the glass panels into their

permanent position. The units must be level, plumb, square and in plane. Install the glass stops, which should have been notched at

predetermined locations according to approved shop drawings, to accomodate thumbwheel operator.

VISION CONTROL

®

INSTALLATION

IMPORTANT NOTE:

Various thumbwheel diameters may occur throughout this order.

Please refer to approved shop drawings to identify the proper thumbwheel diameter size to install.

This operation must be performed before installing the glass units in their respective openings.

Follow the instructions for either left side or right side, as required.

RIGHTLEFT

ADDITIONAL INSTRUCTIONS

FAN-SHAPED THUMBWHEEL OPERATORS

LEFT SIDE AND RIGHT SIDE

STICKERS SHOULD BE FACING OUT

LR

STEP 1

STEP 2

O

P

E

R

A

B

L

E

S

I

D

E

O

P

E

R

A

B

L

E

S

I

D

E

LEFT AND RIGHT SIDES WHEN

VIEWED FROM THE OPERABLE

SIDE OF THE ROOM

LOUVERS IN

OPEN POSITION

LOUVERS IN

OPEN POSITION

RIGHTLEFT

METAL PLATE

SETTING BLOCK

METAL PLATE

SETTING BLOCK

O

P

E

R

A

B

L

E

S

I

D

E

O

P

E

R

A

B

L

E

S

I

D

E

AutoCAD SHX Text
R
Page 46: VISION CONTROL FEATURES R - Unicel

VC 6.5.2

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

2020

VISION CONTROL

®

INSTALLATION

FAN-SHAPED THUMBWHEEL OPERATORS

STEP 3

OPEN POSITION CLOSED POSITION

TURN IN THIS

DIRECTION

TO OPEN THE

BLADES

LEFT SIDE FAN-SHAPED THUMBWHEEL RIGHT SIDE FAN-SHAPED THUMBWHEEL

CLOSED POSITIONOPEN POSITION

TURN IN THIS

DIRECTION

TO CLOSE THE

BLADES

± 115°

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME DOWN

FROM OPERABLE SIDE

NOTE:

ROTATION LIMITED TO

APPROX. 115° INSTEAD OF 180°

LOUVERS COME DOWN

FROM OPERABLE SIDE

± 115°

FULL

STOP

FULL

STOP

TURN IN THIS

DIRECTION

TO OPEN THE

BLADES

TURN IN THIS

DIRECTION

TO CLOSE THE

BLADES

FULL

STOP

FULL

STOP

IMPORTANT NOTE:

Various thumbwheel diameters may occur throughout this order. Please refer to approved shop

drawings to identify the proper thumbwheel diameter size to install.

This operation must be performed before installing the glass units in their respective openings.

Applicable for both left and right sides.

If this orientation is not observed, remove the thumbwheel, flip it and re-install it.

L

L

R

R

AutoCAD SHX Text
R
Page 47: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 6.5.3

2020

VISION CONTROL

®

INSTALLATION

FAN-SHAPED THUMBWHEEL OPERATORS FOR VISION CONTROL

®

UNITS WITH DOUBLE WHEELS

IMPORTANT NOTE FOR INSTALLATION:

1. Do not turn the brass hubs of the

glass units!!

2. Install the wheels, sticker side

facing out. Do not turn the

wheels in any direction.

3. If the wheels are turned, it could

cause irreversible damage to the

mechanism of the unit.

4. Install Vision Control

®

glass in

openings according to shop drawings.

Install glass stops at perimeter, on both

sides of the window.

5. Thumbwheels may now be turned.

S

T

I

C

K

E

R

S

I

D

E

S

H

O

U

L

D

B

E

F

A

C

I

N

G

O

U

T

S

T

I

C

K

E

R

S

I

D

E

S

H

O

U

L

D

B

E

F

A

C

I

N

G

O

U

T

AutoCAD SHX Text
R
Page 48: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 6.6

44.5mm

1 3/4''

44.5mm

1 3/4''

2

5

.

4

m

m

1

"

2020

VISION CONTROL

®

INSTALLATION

THIS SIDE

SHOULD BE

HELD IN PLACE

BY A WORKER

TO PREVENT

THE UNIT FROM

FALLING OUT

SNAP ON

VERTICAL

TRIM

SNAP ON

VERTICAL

TRIM

COEX GLAZING

INSTALLATION

VISION CONTROL

®

IS FURNISHED

FACTORY-GLAZED IN UNICEL'S

ALUMINUM TRIMS FOR 1 3/4" (44.5mm)

THICK DOORS

FOR DOORS: VISION CONTROL

®

FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS

STEP A STEP B STEP C

STEP E STEP F STEP G

REMOVE SNAP-ON

TRIM AT PERIMETER

INTERIOR

SETTING BLOCK

(IF REQUIRED)

BY OTHERS

DOOR

BY OTHERS

INTERIOR

INTERIOR

VIEWED FROM INTERIOR SIDE

SNAP ON TOP

TRIM

SNAP ON BOTTOM

TRIM

DOOR BY OTHERS

COEX

GLAZING

COEX

GLAZING

COEX GLAZING

(SEE STEP G)

DOOR BY OTHERS

COEX GLAZING

(SEE STEP G)

STEP D*

PLASTIC

BLOCKING

PLASTIC BLOCKING

PLASTIC BLOCKING

(BEHAVIORAL / MENTAL HEALTH

APPLICATION)

*THIS STEP IS FOR BEHAVIORAL/MENTAL HEALTH

APPLICATIONS ONLY

PLASTIC BLOCKING

(BEHAVIORAL / MENTAL HEALTH

APPLICATION)

PLASTIC BLOCKING

(BEHAVIORAL / MENTAL HEALTH

APPLICATION)

AutoCAD SHX Text
R
Page 49: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 7.1

2020

Cleaning and maintenance of glass:

· Routinely clean using ordinary window-washing techniques.

· For best results, use liquid glass cleaners or mild household detergents. Do not use cleaning

compounds containing fluorine, strong acids, corrosive alkaline detergents or from glass

surfaces.

Cleaning and maintenance of zinc crank handle, aluminum knobs, or polymer thumbwheel:

· If the crank handle or knob becomes loose, just tighten the allen screw with an allen key

on the side of the crank handle or knob.

· Clean the crank handle or the knob with liquid glass cleaners and the thumbwheel with cleaners

used for polymer.

Cleaning and maintenance of aluminum blocks, oval plates, knobs, and aluminum trims:

· Mild soaps or detergents ruled safe for bare hands should be safe for coated aluminum.

Stronger detergents such as some dishwasher detergents should be carefully spottested. After

cleaning, the finish should be thoroughly rinsed with clean water and dried.

· Avoid abrasive cleaners. Strong solvents or strong cleaner concentrations can cause damage

to painted surfaces. Overcleaning or excessive rubbing can do more harm than good.

· Abrasive materials such as steel wool and abrasive brushes can wear and harm finishes. Do not

scour painted surfaces.

· Never use paint removers, aggressive alkaline, acid or abrasive cleaners. Do not use trisodium

phosphate, highly alkaline or highly acid cleaners. Always do a test surface.

VISION CONTROL

®

OPERATION AND MAINTENANCE

MAINTENANCE INSTRUCTIONS

AutoCAD SHX Text
R
Page 50: VISION CONTROL FEATURES R - Unicel

ARCHITECTURAL

Unicel Architectural Corp.

2155 Fernand-Lafontaine

Longueuil • Québec • J4G 2J4 • Canada

T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144

E: [email protected] • www.unicelarchitectural.com

VC 7.2

2020

VISION CONTROL

®

WARRANTY STATEMENT

During a period of twenty (20) years from date of manufacture, depending on the type of unit

construction and the use to which the unit is put, Vision Control

®

insulating glass units installed in

interior applications are warranted not to develop, under normal conditions, material obstruction of

vision as a result of dust or film formation on the internal glass surface caused by failure of the

hermetic seal other than through glass breakage. Additionally, this warranty covers any internal parts

for malfunction, mechanical failure or premature wear under normal use. Baldor and Pittman motors

are covered up to a one (1)-year period. Somfy motors are covered up to a five (5)-year period. All

other motorized elements are covered up to a one (1)-year period. Glass edge separation, changes

in properties of interlayer, delamination of glass, glass coatings, and material obstruction through

glass not caused by seal failure, are not covered beyond the warranty period offered by the original

supplier of the material. This warranty does not apply to glass breakage or vandalism, and does not

cover replacement and labor costs. Units installed in exterior applications and without breather tubes

or capillary breather tubes are covered up to a ten (10)-year period.

This warranty is effective only if installation is made in accordance with Unicel's specific instructions

and does not apply to units damaged by improper handling or installation. This represents Unicel's

maximum liability. The obligations of Unicel under this warranty are limited to the repair or

replacement, at Unicel's option, of defective parts of the goods. This warranty does not apply to

replacement units beyond the original twenty (20)-year (or ten (10)-year) period to which the original

unit is subjected. Unicel will not be liable for any other expenses involved in the removal of defective

units, installation of replacement units, or any other incidental or consequential damages.

Unicel does not authorize any person, dealer, or distributor to create for it any obligation or liability in

connection with the goods. Leakage will be the sole responsibility of the glass contractor or installer.

This warranty shall be void if the units are subjected to abnormal stresses from the load application

of heat, excessive vibration, building or foundation movement; if glazed with materials which do not

remain resilient for the life of the warranty, or if the methods and materials used in glazing the units

do not completely repel water for the life of the warranty. Unicel reserves the right to inspect, in the

field, any part or unit which is allegedly defective, or to request that the unit(s) be returned to Unicel

for inspection.

This warranty is valid only if contracts have been paid in full.

Unicel Architectural Corp.

AutoCAD SHX Text
R