Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And...
-
Upload
molly-carpenter -
Category
Documents
-
view
224 -
download
0
Transcript of Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And...
![Page 1: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/1.jpg)
Vis-U-Etch™ 7
The Leader
In
Cupric Chloride Regeneration
For High Quality, Low Cost
And Environmental Safety
![Page 2: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/2.jpg)
It’s time to set the record straight...Not all cupric chloride
regeneration systems are created equal!
The Vis-U-EtchTM 7 is the ONLY cupric chloride regeneration system that uses
light transmission to control the etchant.
![Page 3: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/3.jpg)
Highest Quality From ANY Etcher
Light transmission controls etchant with virtually NO FREE ACID.
Eliminating free acid allows the MOST STABLE ETCHANT because there are no sudden releases of chlorine gas which cause variations in etch rate and etch factor.
![Page 4: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/4.jpg)
Most Environmentally Friendly
NO OFFENSIVE HYDROCHLORIC ACID OR CHLORINE GAS ODORS from the etcher while operating. Employees love it!
ALL EQUIPMENT IN THE ETCH ROOM LASTS LONGER without the corrosive atmosphere present with other systems.
![Page 5: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/5.jpg)
Highest Level Of Safety
Sophisticated INPUT CHEMICAL FAILURE ALARM SYSTEM warns of equipment malfunction and shuts down chemical input.
![Page 6: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/6.jpg)
Low Operating Cost
Eliminating free acid provides the MOST EFFICIENT use of chemicals.
Up to 50% LESS WASTE generated through higher copper concentration in etchant.
![Page 7: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/7.jpg)
Proven Technology
The Vis-U-EtchTM 7 has been installed in well OVER 200 LOCATIONS world-wide.
OVER 97% RETENTION RATE for all systems sold over the last 6 years.
![Page 8: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/8.jpg)
Unsurpassed Etching Quality…
Because there is virtually no free acid– The finest lines are possible from any etcher due to
minimal acid undercut.– The most stable etchant is guaranteed yielding the most
consistent quality.– The entire etch room environment is less corrosive,
safer and more productive.
Quality...
![Page 9: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/9.jpg)
High Acid vs. Zero Acid
1
H
2 3 4 5 6 7 8 9 101 E
4
7
2222.52323.52424.52525.52626.52727.52828.529
28.5-29
28-28.5
27.5-28
27-27.5
26.5-27
26-26.5
25.5-26
25-25.5
24.5-25
24-24.5
23.5-24
23-23.5
22.5-23
22-22.5
Figure 1 - Etching Variation @2N (In Microns)
1
H
2 3 4 5 6 7 8 9 10
1 E
4
7
27
29
31
33
35
37
35-37
33-35
31-33
29-31
27-29
Figure 2 - Etching Variation @0N (In Microns)
Quality...
![Page 10: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/10.jpg)
Zero-Free Acid* Vis-U-Etch™ 7 vs. High Acid Normality/O.R.P.
Both panels start the same...
…Etching begins...
…BUT without free acid, straighter side-walls and reduced undercut are guaranteed. Only
the Vis-U-Etch™ 7 using light transmission can deliver this kind of performance!
*Actual Free Acid Normality =<0.05N
Quality...
![Page 11: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/11.jpg)
System Requirements
Vis-U-Etch 7™ can be integrated into any DES line without any problem. However, to achieve the best results, the following requirements should be observed:
Circulation pump should be able to move the entire sump capacity of the whole etcher through the pump within 5 minutes.
Nozzles in the etch chambers should ideally be capable of a flow rate of 3.5 liters per minute with a pressure of 2.5 bar.
Installation...
![Page 12: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/12.jpg)
Installation of the Vis-U-Etch 7™ is simple!
There are only 2 plumbing connections between the Vis-U-Etch 7™ and the etcher, a plumbing connection between the Vis-U-Etch 7™ and the Hydrochloric Acid and Oxidizer Tanks and a connection for the Spent Tank (when used)
Centurion Chemicals personnel will be on site to advise the end-user on the installation, and provide training
It normally takes less than a day to install the Vis-U-Etch 7™ . And most times, production is not even affected!
Installation...
![Page 13: Vis-U-Etch ™ 7 The Leader In Cupric Chloride Regeneration For High Quality, Low Cost And Environmental Safety.](https://reader036.fdocuments.net/reader036/viewer/2022082506/5697bfe81a28abf838cb6584/html5/thumbnails/13.jpg)
Vis-U-Etch™ 7 Partial Customer ListAccudyneAccurate Circuit EngineeringACE Electronics Co.Action Computer ProductsAdvanced ElectronicsAKA (Slovenia)Aspocomp (Finland)Bartlett ManufacturingCal-FlexChemitallic (Denmark)Circuit Systems Inc.Cibo Print (Finland)CoGRA (Sweden)Crown CircuitsDaeDuck ElectronicsDebora ElectronicsDong-A Precision Co.DynacircuitsExpress Circuits (UK)Elco (Italy)Flextronics (UK)Graphic Electronic s (UK)Intec (Slovenia)Jian-Puu ElectronicsKCA ElectronicsL.E. Flex CircuitsLG ElectronicsLintekMarcel Electronics InternationalMektecM-Flex (China)M-Flex (Anaheim)
Motorola Multek (Minnesota)Multi CircuitNarae Electronic Co.New Star ElectronicsNippon Chemical Denshi, Inc.Omni CircuitsPCI / Gomtech ElectronicsPioneer CircuitsPossehl Besi ElectronicsPrime TechnologiesPrintca (Denmark)Printed Circuits UnlimitedPro-TechPyconRed BoardRock IndustriesRogers Corp.Saehan Electronics Co.SamsungSDC CircuitsSelect CircuitsSomacis (Italy)SungWoo ElectronicsTecnomaster (Italy)Technoflex ( UK)The Circuit TreeTotal Circuit ManufacturingTyco (California)UltraPrint (Finland)Wurth (Germany)Yufo Electronics