G&W ELECTRIC PAGE 1 Viper Reclosers with Six Integral Voltage Sensors with six voltage sensors APPLICATIONS Open Bus-Tie Breaker - Either substation mounted or overhead, where the presence or loss of voltage is used to trigger the tie breaker to close and restore power. FDIR - Fault Detection Isolation and Restoration where communications are used between recloser controls to operate and restore power. In the event there is a loss of communication and six voltages are being monitored, the recloser control can even be programmed to deploy FDIR without the need for communications, providing the highest level of reliability. Automatic Transfer - To monitor two independent source voltages. 6VS permits the control to sense loss of voltage on the primary source and verify a stable voltage reading on the secondary source which assures a proper, safe transfer even if communications is lost. Distributed Generation - Where the electric grid is synchronized with backup generators. Having six voltage sensors allows the recloser control to monitor phase angle and voltage amplitude of each phase to close the recloser safely when connecting the generator to the grid. OPERATION Technology - 6VS is accomplished through capacitive voltage dividers embedded in the epoxy insulation of each G&W Viper-S and Viper-ST three phase reclosers now have the option of incorporating six integral capacitive voltage sensors to allow for voltage measurement on both the line and load sides of the device without the need for costly and heavy potential transformers. This makes G&W Viper reclosers with Six Voltage Sensors (6VS) ideal for distribution automation applications and loop or network reconfiguration schemes. phase of the recloser. The sensors have a Low Energy Analog (LEA) output. The capacitive voltage sensors are isolated from the grid and are able to read phase angle and voltage amplitude with a relatively high accuracy. The sensors do not provide power to the recloser control. External sources such as PTs can be supplied to power the relay. Accuracy - The voltage sensors have been tested in a third party laboratory. Voltage sensing amplitude accuracy is +/- 2 % when tested as a system from -10°C (14°F) to +45°C (113°F). The VS accuracy is +/-4% from -40°C (-40°F) to +65°C (149°F). The phase angle accuracy is +/-1° throughout the full temperature range. Current monitoring is provided through integral multi-ratio current transformers encapsulated within the module of each phase. Ratios available are 1000:1 or 500:1. Inputs to the control are field changeable. CT accuracy is +/- 1%. Center polemount Viper-ST with six voltage sensors. u Viper-S Viper-ST

Transcript of Viper Reclosers with Six Integral Voltage · PDF fileViper Reclosers with Six Integral Voltage...

Page 1: Viper Reclosers with Six Integral Voltage · PDF fileViper Reclosers with Six Integral Voltage Sensors. ... Polemount Center Bracket for Solid Dielectric Potential Transformers ...

G & W E L E C T R I C P A G E 1

Viper Reclosers with Six Integral Voltage Sensors

with six voltage sensors

ApplicAtionsOpen Bus-Tie Breaker - Either substation mounted or overhead, where the presence or loss of voltage is used to trigger the tie breaker to close and restore power.

FDIR - Fault Detection Isolation and Restoration where communications are used between recloser controls to operate and restore power. In the event there is a loss of communication and six voltages are being monitored, the recloser control can even be programmed to deploy FDIR without the need for communications, providing the highest level of reliability.

Automatic Transfer - To monitor two independent source voltages. 6VS permits the control to sense loss of voltage on the primary source and verify a stable voltage reading on the secondary source which assures a proper, safe transfer even if communications is lost.

Distributed Generation - Where the electric grid is synchronized with backup generators. Having six voltage sensors allows the recloser control to monitor phase angle and voltage amplitude of each phase to close the recloser safely when connecting the generator to the grid.

operAtionTechnology - 6VS is accomplished through capacitive voltage dividers embedded in the epoxy insulation of each

G&W Viper-S and Viper-ST three phase reclosers now have the option of incorporating six integral capacitive voltage sensors to allow for voltage measurement on both the line and load sides of the device without the need for costly and heavy potential transformers. This makes G&W Viper reclosers with Six Voltage Sensors (6VS) ideal for distribution automation applications and loop or network reconfiguration schemes.

phase of the recloser. The sensors have a Low Energy Analog (LEA) output. The capacitive voltage sensors are isolated from the grid and are able to read phase angle and voltage amplitude with a relatively high accuracy. The sensors do not provide power to the recloser control. External sources such as PTs can be supplied to power the relay.

Accuracy - The voltage sensors have been tested in a third party laboratory. Voltage sensing amplitude accuracy is +/- 2 % when tested as a system from -10°C (14°F) to +45°C (113°F). The VS accuracy is +/-4% from -40°C (-40°F) to +65°C (149°F). The phase angle accuracy is +/-1° throughout the full temperature range. Current monitoring is provided through integral multi-ratio current transformers encapsulated within the module of each phase. Ratios available are 1000:1 or 500:1. Inputs to the control are field changeable. CT accuracy is +/- 1%.

Center polemount Viper-ST with six voltage sensors. u

Viper-S Viper-ST

Page 2: Viper Reclosers with Six Integral Voltage · PDF fileViper Reclosers with Six Integral Voltage Sensors. ... Polemount Center Bracket for Solid Dielectric Potential Transformers ...

G & W E L E C T R I C P A G E 2

with six voltage sensors

Viper-ST 32-Pin Connector & Junction Box68”

(1727mm)

24”(610mm)

24”(610mm)

50”(1270mm)

24” Phase Spacing For Two Oil Filled Potential Transformers Polemount Center Bracket (15kV shown)

Front View Side View

114”(2896mm)Height as

shown

150”(3810mm)

Max

105”(2667mm)Minimum

Side View

45° Substation Mount

Adjustable Height Frame

IEEE Bushing Interface

Voltage Sensor

Vacuum Interrupter

Epoxy Encapsulation

Drive Assembly

Magnetic Actuator

Current/ Voltage

Sensors

Manual Open

Handle

Position Indicator

15”(381mm)

15”(381mm)

49”(1238mm)

49”(1238mm)

Standard Polemount Center Bracket

Front View Side View

(15kV shown)

Polemount Center Bracket for Solid Dielectric Potential Transformers(38kV shown)

57”(1445mm)

15”(381mm)

15”(381mm)

Front View Side View

101”(2562mm)

Page 3: Viper Reclosers with Six Integral Voltage · PDF fileViper Reclosers with Six Integral Voltage Sensors. ... Polemount Center Bracket for Solid Dielectric Potential Transformers ...

G & W E L E C T R I C P A G E 3

with six voltage sensors

Viper-S 19-pin control power connector and 8-pin 6VS LEA quick connector

Standard Polemount Center Bracket(15kV shown)

113”(2873mm)Height as

shown

133”(2968mm)

Max

88”(2222mm)Minimum

Side View

This

draw

ing an

d the

infor

matio

n the

G&W ELECTRIC Co.

* ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS.

1.48[38]

27.00[686]

MOUNTING

2.02[51]

Ø2.25[57]TYP.

3D M

ODEL

MC

ERRO

RS 0

DRAW

ING

MC

ERRO

RS 1

3D M

ODEL

LAST

CHE

CKED

Fri D

ec 09

2011

13:54

:38 G

MT-

0600

VIP

-S_C

UST

DRAW

ING

LAST

CHE

CKED

Wed

Sep

28 20

11 09

:41:01

GM

T-06

00 ST

ANDA

RDSH

EET 1

of 2

1 of 2SHEET: SCALE:Sep-28-11 DATE:MLAPPR BY:

DRAWING NO.

D96VS 8811 _15Sep-28-11DATE:RSPDRAWN BY:

VIP388ER-12SCAT. NO.:

15KV 800 AMP SOLID DIELECTRIC RECLOSERWIT 6 INTERNAL VOLTAGE SENSING AND

(1) OIL FILLED PT'S

VIP388ER-12S

ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING.

REVISIONS

DATECHANGEREV.

DRAWING REVIEW TEAM

ENTRANCESWAY

Z SIDE

Y SIDE

1000:1

SWITCH ELECTRICAL INFORMATION

MAXIMUM DESIGN VOLTAGEIMPULSE LEVEL ( BIL )AC 1 MIN. WITHSTAND (DRY)AC 10 SEC. WITHSTAND (WET)CURRENT CONTINUOUSCURRENT INTERRUPTING SYM.MAKING CURRENT ASYM.3 SEC. RATING RMS SYM.

IN SERVICE WEIGHT APPROX LBS/ KG

KVKVKVKVAMPKAKAKA

27125605080012.52012.5

800 363

38KV 800 AMP DEADBREAK INTERFACE WITH 27KV SILICONE SHED INSULATORS

38KV 800 AMP DEADBREAK INTERFACE WITH 27KV SILICONE SHED INSULATORS

NOTES: 1. 304 STAINLESS STEEL MECHANISM HOUSING PAINTED ASA 70 LIGHT GRAY PER SPEC 223.011-82. 2. INTERRUPTER MODULES ARE NOT INTENDED FOR DEAD ENDING. SEPARATE STRAIN RELIEF IS REQUIRED FOR CABLES. 3. MANUAL TRIP LEVER EQUIPPED WITH MECHANICAL AND ELECTRICAL LOCKOUT OF CLOSING CIRCUIT WHEN LEVER IS IN THE TRIPPED POSITION. 4. Z SIDE ENTRANCE, SILICONE SHED INSULATORS CREEPAGE DISTANCE IS APPROXIMATELY 28.50 INCHES [724 MM]. 5. Y SIDE ENTRANCE, SILICONE SHED INSULATORS CREEPAGE DISTANCE IS APPROXIMATELY 28.50 INCHES [724 MM] 6. FOR MOUNTING USE 1/2" [13 MM] DIAMETER BOLTS AND WASHERS MINIMUM AND 3/4" [19 MM] DIAMETER BOLTS AND WASHERS MAXIMUM. 7. RECLOSER EQUIPPED WITH 1000/500:1 CURRENT TRANSFORMERS FACTORY SET AT 1000:1 RATIO. REFER TO INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR CHANGING CURRENT TRANSFORMER RATIO IN THE FIELD. 8. MOUNTING BRACKET WILL FIT 9" [229 MM] TO 14" [356MM] DIAMETER POLE. 9. LIGHTNING ARRESTERS SHOWN IN PHANTOM TO BE PROVIDED BY CUSTOMER.

SEL651R143GAX20113C4

SHIPPING WEIGHT APPROX LBS/ KG1200 544

THREE LINE DIAGRAM

N/A

BACK VIEW

BOTTOM VIEW

GROUND BOSSWITH 1/2-13THREADS

CONTROL CABLEFEEDTHRU CONNECTOR(AMPHENOL PART NUMBER97-3102A-22-14P)

VOLTAGE SENSING CABLEFEEDTHRU CONNECTOR(AMPHENOL PART NUMBERPT02SE-12-8S)

5 DIGIT MECHANICALOPERATION COUNTER

CONTACT POSITIONINDICATOR(RED-CLOSED/GREEN-OPEN)

VENT FORMECHANISMHOUSING

STAINLESS STEELCOVER PLATE

DATE G&W NO.

CUSTOMER

ORDER NO.

FOR RECORD

FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED

PRINT IDENTIFICATION

ITEM NO.

CT RATIO

CONTROLLER NO.

DC/DC OPTION USES OUTPUT

45° Substation Mount

15.5”(394mm)

15.5”(394mm)

This

draw

ing an

d the

infor

matio

n the

G&W ELECTRIC Co.

* ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS.

1.48[38]

27.00[686]

MOUNTING

2.02[51]

Ø2.25[57]TYP.

3D M

ODEL

MC

ERRO

RS 0

DRAW

ING

MC

ERRO

RS 1

3D M

ODEL

LAST

CHE

CKED

Fri D

ec 09

2011

13:54

:38 G

MT-

0600

VIP

-S_C

UST

DRAW

ING

LAST

CHE

CKED

Wed

Sep

28 20

11 09

:41:01

GM

T-06

00 ST

ANDA

RDSH

EET 1

of 2

1 of 2SHEET: SCALE:Sep-28-11 DATE:MLAPPR BY:

DRAWING NO.

D96VS 8811 _15Sep-28-11DATE:RSPDRAWN BY:

VIP388ER-12SCAT. NO.:

15KV 800 AMP SOLID DIELECTRIC RECLOSERWIT 6 INTERNAL VOLTAGE SENSING AND

(1) OIL FILLED PT'S

VIP388ER-12S

ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING.

REVISIONS

DATECHANGEREV.

DRAWING REVIEW TEAM

ENTRANCESWAY

Z SIDE

Y SIDE

1000:1

SWITCH ELECTRICAL INFORMATION

MAXIMUM DESIGN VOLTAGEIMPULSE LEVEL ( BIL )AC 1 MIN. WITHSTAND (DRY)AC 10 SEC. WITHSTAND (WET)CURRENT CONTINUOUSCURRENT INTERRUPTING SYM.MAKING CURRENT ASYM.3 SEC. RATING RMS SYM.

IN SERVICE WEIGHT APPROX LBS/ KG

KVKVKVKVAMPKAKAKA

27125605080012.52012.5

800 363

38KV 800 AMP DEADBREAK INTERFACE WITH 27KV SILICONE SHED INSULATORS

38KV 800 AMP DEADBREAK INTERFACE WITH 27KV SILICONE SHED INSULATORS

NOTES: 1. 304 STAINLESS STEEL MECHANISM HOUSING PAINTED ASA 70 LIGHT GRAY PER SPEC 223.011-82. 2. INTERRUPTER MODULES ARE NOT INTENDED FOR DEAD ENDING. SEPARATE STRAIN RELIEF IS REQUIRED FOR CABLES. 3. MANUAL TRIP LEVER EQUIPPED WITH MECHANICAL AND ELECTRICAL LOCKOUT OF CLOSING CIRCUIT WHEN LEVER IS IN THE TRIPPED POSITION. 4. Z SIDE ENTRANCE, SILICONE SHED INSULATORS CREEPAGE DISTANCE IS APPROXIMATELY 28.50 INCHES [724 MM]. 5. Y SIDE ENTRANCE, SILICONE SHED INSULATORS CREEPAGE DISTANCE IS APPROXIMATELY 28.50 INCHES [724 MM] 6. FOR MOUNTING USE 1/2" [13 MM] DIAMETER BOLTS AND WASHERS MINIMUM AND 3/4" [19 MM] DIAMETER BOLTS AND WASHERS MAXIMUM. 7. RECLOSER EQUIPPED WITH 1000/500:1 CURRENT TRANSFORMERS FACTORY SET AT 1000:1 RATIO. REFER TO INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR CHANGING CURRENT TRANSFORMER RATIO IN THE FIELD. 8. MOUNTING BRACKET WILL FIT 9" [229 MM] TO 14" [356MM] DIAMETER POLE. 9. LIGHTNING ARRESTERS SHOWN IN PHANTOM TO BE PROVIDED BY CUSTOMER.

SEL651R143GAX20113C4

SHIPPING WEIGHT APPROX LBS/ KG1200 544

THREE LINE DIAGRAM

N/A

BACK VIEW

BOTTOM VIEW

GROUND BOSSWITH 1/2-13THREADS

CONTROL CABLEFEEDTHRU CONNECTOR(AMPHENOL PART NUMBER97-3102A-22-14P)

VOLTAGE SENSING CABLEFEEDTHRU CONNECTOR(AMPHENOL PART NUMBERPT02SE-12-8S)

5 DIGIT MECHANICALOPERATION COUNTER

CONTACT POSITIONINDICATOR(RED-CLOSED/GREEN-OPEN)

VENT FORMECHANISMHOUSING

STAINLESS STEELCOVER PLATE

DATE G&W NO.

CUSTOMER

ORDER NO.

FOR RECORD

FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED

PRINT IDENTIFICATION

ITEM NO.

CT RATIO

CONTROLLER NO.

DC/DC OPTION USES OUTPUT

66”(1663mm)

46”(1173mm)

Front View Side View

Polemount Center Bracket with Oil Filled Potential Transformer(15kV shown)

Epoxy Encapsulation

Voltage Sensor

Vacuum Interrupter

Drive Assembly

Manual Open Handle

Position Indicator

Current/Voltage

Sensors

IEEE Bushing Interface

15.5”(394mm)

15.5”(394mm)

84”(2127mm)

51”(1292mm)

Front View Side View

Polemount Center Bracket with Oil Filled Potential Transformers(27kV shown)

This

draw

ing an

d the

infor

matio

n the

reon a

re an

d rem

ain th

e pr

oper

ty of

G&W

and a

re no

t to b

e cop

ied, re

prod

uce

d or d

iclos

ed to

othe

rs wi

thou

t the

ex

pres

sed w

ritten

cons

ent o

f G&W

.

G&W ELECTRIC Co.

* ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS.

1.48[38]

27.00[686]

MOUNTING

2.02[51]

Ø2.25[57]TYP.

D96

VS 8

811

_15

DWG.

NO.

:3D

MOD

EL M

C ER

RORS

0DR

AWIN

G M

C ER

RORS

13D

MOD

EL LA

ST C

HECK

ED Fr

i Dec

09 20

11 13

:54:38

GM

T-06

00 V

IP-S

_CUS

TDR

AWIN

G LA

ST C

HECK

ED W

ed Se

p 28

2011

09:41

:01 G

MT-

0600

STAN

DARD

SHEE

T 1 o

f 2

1 of 2SHEET: SCALE:Sep-28-11 DATE:MLAPPR BY:

DRAWING NO.

D96VS 8811 _15Sep-28-11DATE:RSPDRAWN BY:

VIP388ER-12SCAT. NO.:

15KV 800 AMP SOLID DIELECTRIC RECLOSERWIT 6 INTERNAL VOLTAGE SENSING AND

(1) OIL FILLED PT'S

VIP388ER-12S

ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING.

REVISIONS

DATECHANGEREV.

DRAWING REVIEW TEAM

ENTRANCESWAY

Z SIDE

Y SIDE

1000:1

SWITCH ELECTRICAL INFORMATION

MAXIMUM DESIGN VOLTAGEIMPULSE LEVEL ( BIL )AC 1 MIN. WITHSTAND (DRY)AC 10 SEC. WITHSTAND (WET)CURRENT CONTINUOUSCURRENT INTERRUPTING SYM.MAKING CURRENT ASYM.3 SEC. RATING RMS SYM.

IN SERVICE WEIGHT APPROX LBS/ KG

KVKVKVKVAMPKAKAKA

27125605080012.52012.5

800 363

38KV 800 AMP DEADBREAK INTERFACE WITH 27KV SILICONE SHED INSULATORS

38KV 800 AMP DEADBREAK INTERFACE WITH 27KV SILICONE SHED INSULATORS

NOTES: 1. 304 STAINLESS STEEL MECHANISM HOUSING PAINTED ASA 70 LIGHT GRAY PER SPEC 223.011-82. 2. INTERRUPTER MODULES ARE NOT INTENDED FOR DEAD ENDING. SEPARATE STRAIN RELIEF IS REQUIRED FOR CABLES. 3. MANUAL TRIP LEVER EQUIPPED WITH MECHANICAL AND ELECTRICAL LOCKOUT OF CLOSING CIRCUIT WHEN LEVER IS IN THE TRIPPED POSITION. 4. Z SIDE ENTRANCE, SILICONE SHED INSULATORS CREEPAGE DISTANCE IS APPROXIMATELY 28.50 INCHES [724 MM]. 5. Y SIDE ENTRANCE, SILICONE SHED INSULATORS CREEPAGE DISTANCE IS APPROXIMATELY 28.50 INCHES [724 MM] 6. FOR MOUNTING USE 1/2" [13 MM] DIAMETER BOLTS AND WASHERS MINIMUM AND 3/4" [19 MM] DIAMETER BOLTS AND WASHERS MAXIMUM. 7. RECLOSER EQUIPPED WITH 1000/500:1 CURRENT TRANSFORMERS FACTORY SET AT 1000:1 RATIO. REFER TO INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR CHANGING CURRENT TRANSFORMER RATIO IN THE FIELD. 8. MOUNTING BRACKET WILL FIT 9" [229 MM] TO 14" [356MM] DIAMETER POLE. 9. LIGHTNING ARRESTERS SHOWN IN PHANTOM TO BE PROVIDED BY CUSTOMER.

SEL651R143GAX20113C4

SHIPPING WEIGHT APPROX LBS/ KG1200 544

THREE LINE DIAGRAM

N/A

FRONT VIEW

BACK VIEW

PT 1

BOTTOM VIEW

RIGHT VIEW

GROUND BOSSWITH 1/2-13THREADS

CONTROL CABLEFEEDTHRU CONNECTOR(AMPHENOL PART NUMBER97-3102A-22-14P)

VOLTAGE SENSING CABLEFEEDTHRU CONNECTOR(AMPHENOL PART NUMBERPT02SE-12-8S)

5 DIGIT MECHANICALOPERATION COUNTER

CONTACT POSITIONINDICATOR(RED-CLOSED/GREEN-OPEN)

VENT FORMECHANISMHOUSING

STAINLESS STEELCOVER PLATE

DATE G&W NO.

CUSTOMER

ORDER NO.

FOR RECORD

FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED

PRINT IDENTIFICATION

ITEM NO.

CT RATIO

CONTROLLER NO.

DC/DC OPTION USES OUTPUT

15.5”(394mm)

15.5”(394mm)

This

draw

ing an

d the

info

rmati

on th

ere

on ar

e and

rem

ain th

e pr

oper

ty of

G&W

and a

re no

t to b

e cop

ied, re

prod

uce

d or d

iclos

ed to

othe

rs wi

thou

t the

ex

pres

sed w

ritte

n con

sent

of G

&W.

G&W ELECTRIC Co.

* ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS.

1.48[38]

27.00[686]

MOUNTING

2.02[51]

Ø2.25[57]TYP.

D96

VS 8

811

_15

DWG.

NO.

:3D

MOD

EL M

C ER

RORS

0DR

AWIN

G M

C ER

RORS

13D

MOD

EL LA

ST C

HECK

ED Fr

i Dec

09 20

11 13

:54:38

GM

T-06

00 V

IP-S

_CUS

TDR

AWIN

G LA

ST C

HECK

ED W

ed Se

p 28

2011

09:41

:01 G

MT-

0600

STAN

DARD

SHEE

T 1 o

f 2

1 of 2SHEET: SCALE:Sep-28-11 DATE:MLAPPR BY:

DRAWING NO.

D96VS 8811 _15Sep-28-11DATE:RSPDRAWN BY:

VIP388ER-12SCAT. NO.:

15KV 800 AMP SOLID DIELECTRIC RECLOSERWIT 6 INTERNAL VOLTAGE SENSING AND

(1) OIL FILLED PT'S

VIP388ER-12S

ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING.

REVISIONS

DATECHANGEREV.

DRAWING REVIEW TEAM

ENTRANCESWAY

Z SIDE

Y SIDE

1000:1

SWITCH ELECTRICAL INFORMATION

MAXIMUM DESIGN VOLTAGEIMPULSE LEVEL ( BIL )AC 1 MIN. WITHSTAND (DRY)AC 10 SEC. WITHSTAND (WET)CURRENT CONTINUOUSCURRENT INTERRUPTING SYM.MAKING CURRENT ASYM.3 SEC. RATING RMS SYM.

IN SERVICE WEIGHT APPROX LBS/ KG

KVKVKVKVAMPKAKAKA

27125605080012.52012.5

800 363

38KV 800 AMP DEADBREAK INTERFACE WITH 27KV SILICONE SHED INSULATORS

38KV 800 AMP DEADBREAK INTERFACE WITH 27KV SILICONE SHED INSULATORS

NOTES: 1. 304 STAINLESS STEEL MECHANISM HOUSING PAINTED ASA 70 LIGHT GRAY PER SPEC 223.011-82. 2. INTERRUPTER MODULES ARE NOT INTENDED FOR DEAD ENDING. SEPARATE STRAIN RELIEF IS REQUIRED FOR CABLES. 3. MANUAL TRIP LEVER EQUIPPED WITH MECHANICAL AND ELECTRICAL LOCKOUT OF CLOSING CIRCUIT WHEN LEVER IS IN THE TRIPPED POSITION. 4. Z SIDE ENTRANCE, SILICONE SHED INSULATORS CREEPAGE DISTANCE IS APPROXIMATELY 28.50 INCHES [724 MM]. 5. Y SIDE ENTRANCE, SILICONE SHED INSULATORS CREEPAGE DISTANCE IS APPROXIMATELY 28.50 INCHES [724 MM] 6. FOR MOUNTING USE 1/2" [13 MM] DIAMETER BOLTS AND WASHERS MINIMUM AND 3/4" [19 MM] DIAMETER BOLTS AND WASHERS MAXIMUM. 7. RECLOSER EQUIPPED WITH 1000/500:1 CURRENT TRANSFORMERS FACTORY SET AT 1000:1 RATIO. REFER TO INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR CHANGING CURRENT TRANSFORMER RATIO IN THE FIELD. 8. MOUNTING BRACKET WILL FIT 9" [229 MM] TO 14" [356MM] DIAMETER POLE. 9. LIGHTNING ARRESTERS SHOWN IN PHANTOM TO BE PROVIDED BY CUSTOMER.

SEL651R143GAX20113C4

SHIPPING WEIGHT APPROX LBS/ KG1200 544

THREE LINE DIAGRAM

N/A

FRONT VIEW

BACK VIEW

PT 1

BOTTOM VIEW

RIGHT VIEW

GROUND BOSSWITH 1/2-13THREADS

CONTROL CABLEFEEDTHRU CONNECTOR(AMPHENOL PART NUMBER97-3102A-22-14P)

VOLTAGE SENSING CABLEFEEDTHRU CONNECTOR(AMPHENOL PART NUMBERPT02SE-12-8S)

5 DIGIT MECHANICALOPERATION COUNTER

CONTACT POSITIONINDICATOR(RED-CLOSED/GREEN-OPEN)

VENT FORMECHANISMHOUSING

STAINLESS STEELCOVER PLATE

DATE G&W NO.

CUSTOMER

ORDER NO.

FOR RECORD

FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED

PRINT IDENTIFICATION

ITEM NO.

CT RATIO

CONTROLLER NO.

DC/DC OPTION USES OUTPUT

49”(1234mm)

46”(1173mm)

Front View Side View

Page 4: Viper Reclosers with Six Integral Voltage · PDF fileViper Reclosers with Six Integral Voltage Sensors. ... Polemount Center Bracket for Solid Dielectric Potential Transformers ...

rAtingsReclosers are designed, tested and built per IEEE C37.60 latest version, IEC 1109-Section 5.3.4, Annex C. Certified test reports are available. The recloser is rated:

Voltage Class (kV) 15 25 35

Max System Voltage (kV) 15.5 27 38

BIL (kV) 110 125 150

Continuous Current (A) 800 800 800

8 Hr. Overload, at 20° C 960 960 960

Interrupting Rating RMS (kA) 12.5 12.5 12.5

Making Current, RMS, asym (kA) 20 20 20

Peak, asym (kA) 32 32 32

Short Circuit Current, kA sym, 3 second 12.5 12.5 12.5

60Hz Withstand, Dry, 1 min (kV rms) 50 60 70

60Hz Withstand, Wet, 10 sec (kV rms) 45 50 60

Mechanical Operations 10,000 10,000 10,000

6Vs leA FeAtures compArison chArt

Feature Viper-S Viper-ST

Basic Features

6VS LEA S S

Mechanically Ganged S -

Triple Option - S

Trip / Lock Out Handle S S

Mechanical Block S S

Removable Silicone Insulators S S

Magnetic Actuator S S

Trip Spring S S

Grounded Solid Dielectric Modules S S

Polemount Frame S S

Integrated 1000/500: 1 CTs S S

Dead-line Operation S S

“L” Shaped Modules S S

32-pin Interface - S

19-pin Interface S -

Other Features

Six 0-144 VAC Analog VS O -

14-pin Interface without dead-line operation O -

Site-Ready Design O O

Substation Frames O O

External CTs O O

Customized Frames O O

Control Packages

SEL-651R S S

Other Custom Relay Solutions O -

LegendStandard S

Option ONot Applicable -

FeAturesOperator Safety - Vacuum interrupters are sealed within solid dielectric insulation providing fully shielded modules. The module housing, being at ground potential, provides additional safety. A hookstick operable, manual trip and lockout handle prohibits operation either from the control or remotely. A mechanical blocking device further assures against accidental close through the handle. An open and closed contact indicator verifies contact position. Contact status and lock-out condition can also be verified at the control.

Reliability - Having both the current and voltage sensors embedded into the epoxy module protects them from environmental damage or contamination and makes for a cleaner, and less cluttered installation. Other manufacturers must use expensive, external add-on sensors or potential transformers to accomplish the same functionality which can significantly increase installation costs and result in a much more congested appearance.

Compact, Lightweight Construction - Built-in sensors eliminate the need for heavy, add-on potential transformers or other sensors significantly reducing the overall weight of the installation. The Viper-ST has one single control cable that brings all voltage, current, breaker status and trip/close information into the control. The Viper-S comes with a 19-pin interface and an 8-pin cable for the voltage sensors.

G&W Electric Company • 305 W. Crossroads Pkwy • Bolingbrook, IL 60440 USA • 708.388.5010 • Fax 708.388.0755 • gwelec.comCatalog VIP6VS, January 2012