Village of Lemont Historic Preservation Commission sion
Transcript of Village of Lemont Historic Preservation Commission sion
HISTORIC PRESERVATION COMMISSION
AGENDA
SPECIAL MEETING
November 19, 2015 – 6:30 p.m.
LEMONT VILLAGE HALL
418 MAIN STREET
I. CALL TO ORDER
II. ROLL CALL
III. APPROVAL OF MINUTES: Meeting September 3, 2015
IV. CHAIRMAN’S REPORT
V. PUBLIC HEARINGS
VI. APPLICATIONS
A. Certificate of Appropriateness for addition to La
Dolce Vita restaurant, 107 Stephen Street.
VII. NEW BUSINESS
VIII. PLANNING & ECONOMIC DEVELOPMENT DIRECTOR
COMMENTS
A. National Register Application: Commercial District
update.
B. St. Patrick School Building
IX. AUDIENCE PARTICIPATION
X. ADJOURN
Village of Lemont
Historic Preservation Commission sion
418 Main Street · Lemont, Illinois 60439 phone 630-257-1595 · fax 630-257-1598
SH
EE
T N
o.
NB
RE
VIS
ION
SP
LAN
No.
DA
TE:
DR
AW
N B
Y:
SC
ALE
:
AP
PR
OV
ED
BY
:
n. b
atis
tich,
arc
hitec
tsM
EA
DO
WB
RO
OK
OFF
ICE
CE
NTE
R16
W4
75 S
. FR
ON
TAG
E R
D.,
SU
ITE
20
1B
UR
R R
IDG
E, I
L 6
05
27
(63
0) 9
86
-177
3
DO
NO
T S
CA
LE D
RA
WIN
GS
CO
NTR
AC
TOR
SH
ALL
VE
RIF
Y A
LL P
LAN
A
ND
DIM
EN
SIO
NS
AN
D C
ON
DIT
ION
S O
N
THE
JO
B A
ND
SH
ALL
IMM
ED
IATE
LY N
OTI
FY
THE
AR
CH
ITE
CTS
, IN
WR
ITIN
G, O
F A
NY
D
ISC
RE
PA
NC
IES
BE
FOR
E P
RO
CE
ED
ING
W
ITH
WO
RK
OR
BE
RE
SP
ON
SIB
LE F
OR
SA
ME
.
I HE
RE
BY
CE
RTI
FY T
HA
T TH
ES
E P
LAN
S W
ER
E
PR
EP
AR
ED
BY
ME
OR
UN
DE
R M
Y S
UP
ER
VIS
ION
AN
D T
HA
T TH
EY
CO
MP
LY T
O T
HE
BE
ST
OF
MY
KN
OW
LED
GE
AN
D B
ELI
EF
WIT
H T
HE
R
EQ
UIR
EM
EN
TS O
F TH
E B
UIL
DIN
G C
OD
E.
STON E VENEER TO MATCHTHE EXISTING STONE
340 # T EXTURED ASPHALTSHINGLES
COPP ER FLASHING
LIMESTON E SILL TO MATCHTHE EXISTING SILL
FIBE R CEMENT PANELS.FAST EN TO STEEL STUDS
1" L OW- E INSULATED GLASSTRANSOM
12MATCH W/EXISTING
7'-6"
RADIU
S
EXIST ING ADJACENT BUILDING
3'- 6" H IGH METAL GUARDRAILINGSYSTEM
1 1/ 2" D IAMET ER STEEL RAILINGS
1" X 1" STEEL SP IND LES A T 4 3/4" O.C. SPINDLES SHALL BE SPACEDSO T HAT A 4 " ROUND OBJECT CANNOT PASS THROUGH
NEW STO NE VENEER TO MATCHTHE EXISTING
SING LE PLY ROOFING
EXIST ING ADJACENT BUILDING
ALUM INUM G RAVEL STOP. COLOR IS TO MATC H T HAT OF THE ALUMINUMGUTTERS
3'- 0" H IGH METAL RAILING SYSTEMWITH 1 1/2" DIA. RAILS
PROV IDE AN EXPANSION JOINT IN BETWEENTHE NEW AN D EXISTING MASONRY WALL
4" LIMESTONE SILL
SEAML ESS A LUMINUM GUTTERS ANDALUM INUM DOWNSPOUTS
340 # T EXTU RED ASPHALT SHINGLES
ALUM INUM VE NTS. ALSO PLASTIC FLASH AROU ND THE ROOF VENTS
REMOV E TH E EX ISTING GUTTERS AND DOWNSPOUTS AND INST ALL NEW SEAMLESS ALUMINUM GUTTERS AND ALUM INUM DOWNSPOUTS
1212
EXIST ING STONE IS TO REMAIN
LINE OF NEW BUILDINGLINE OF EXISTING BUILDING
ALUMI NUM DRIP CAP. MATCH COLOR WITH TH AT OF THE GUTTERS
NEW STO NE VENE ER IS TO MATCH THE EXISTINGSTON E. ALI GN NEW STONE WITH THAT OF THEEXIST ING STONE
NEW LIME STON E SIL L. MATCH WITH THE EXISTINGLIMES TONE SILL
3'-0"
RADIU
S
EXPOSED COPPER FLASHING
NEW STO NE T O MATCH THE EXISTINGSTONE
EXTERIOR DOORS AND WINDOWS
DOORS:PROV IDE "P ELLA " O R EQ UAL ALUMINUM CLAD FULL LITE COMMERCIAL DOORDOO RS W ITH ALU MINU M CLA D FULL LITE SIDELITES. PROVIDE 1" LOW- ETEMP ERED INSULA TED GLASS FOR THE DOORS AND SIDELITES.
EXTERIOR DOORS AND WINDOWS
VIN YL SIDING
VIN YL SIDING
ALUM INUM CLAD FULL LITECOMMER CIAL DOOR 3'-0" X 7'-0"WIT H ( 2 )- 1'-6" X 7'-0" ALUMINUMCLAD FULL LITE SIDELITES.PROVID E 1" LOW- E TEMPEREDINSU LATE D GLASS FOR THE DOORAND THE SIDELITES.
REUSE TH E EX ISTING WINDOWS THAT WERE REMOVEDFROM THE EXI STING BUILDING IN THE NEW ADDITION
ALL WIN DOW S IN THE EXISTING BUILDINGARE TO REMAIN
LINE OF NEW BUILDING LINE OF EXISTING BUILDING
VERIF Y THE D IMENSION S OF IN- PLACE AND SUBSEQUENT CONSTRUCTION ANDACCUR ATEL Y FI T THIS PART OF THE WORK TO OTHER CONSTRUCTION
PROV IDE TIG HT JOIN TS A ND EFFECTIVELY SEAL THE COMPONENT PARTS OF THEWIN DOW S AN D T HEIR JO INTS TO OTHER WORK AGAINST WATER LEAKAGE ANDAIR IN FILTRATION.
WINDOWSREUSE TH E EX ISTIN G W IND OWS THAT WERE REMOVED FROM THE EXISTING BUILDINGIN THE NEW ADDITION
DOORS:MINU MUM U- FACTOR= .32
REUSE TH E EXISTING WINDOWSTHA T W ERE REMOVED FROMTHE EXISTING BUILDING INTHE NEW ADDITION
EXISTING BUILDING ISTO REMAIN
6" X 6" P RESSURE TREATEDWOO D P OSTS ( 3 TOTAL )COVE RED WITH WOOD 2-PIECECOLUMN
2- 2' -0" X 2'-6" STEELSERVI CE DOORS
EXPA NSIO N J OINT IN BETWEEN THE NEWAND EXI STING MASONRY WALLS
WEST ELEVATION
EAST ELEVATIONSCALE 1/4"- 1'-0"
SCALE 1/4"- 1'-0"
NEW MET AL AWNING IS TO MATCHTHE EXIST ING METAL AWNINGS
SOUTH ELEVATION
NORTH ELEVATIONREMOV E TH E EX ISTING SHINGLES AND FELT PAPER AND IN STALL N EW 30 # FELT PAPER AND NEW 340 #TEXT URED ASP HALT SHINGLES OVER THE EXISTING SHEATHING
1/2" PREMO ULDED EXPANSION JOINT
SEALANT
EXIST ING STONE WALL
CONT INUO US 4" X 4" X 1/4" STEELANG LE W ITH 3/8" DIA. EXPANSIONANCH ORS AT 4'-0" O.C.
SEALANT
NEW MASONRY WALL
EXPANSION JT. DETAILSCALE 1 1 /2" - 1'-0"
SCALE 1/4"- 1'-0"
JUNE
29, 2
015
NB 0
629-
15
A - 3
107 S
tephen
St._
__Lem
ont, IL
Addit
ion to
:La
Dolc
e Vita
SH
EE
T N
o.
NB
RE
VIS
ION
SP
LAN
No.
DA
TE:
DR
AW
N B
Y:
SC
ALE
:
AP
PR
OV
ED
BY
:
n. b
atis
tich,
arc
hitec
tsM
EA
DO
WB
RO
OK
OFF
ICE
CE
NTE
R16
W4
75 S
. FR
ON
TAG
E R
D.,
SU
ITE
20
1B
UR
R R
IDG
E, I
L 6
05
27
(63
0) 9
86
-177
3
DO
NO
T S
CA
LE D
RA
WIN
GS
CO
NTR
AC
TOR
SH
ALL
VE
RIF
Y A
LL P
LAN
A
ND
DIM
EN
SIO
NS
AN
D C
ON
DIT
ION
S O
N
THE
JO
B A
ND
SH
ALL
IMM
ED
IATE
LY N
OTI
FY
THE
AR
CH
ITE
CTS
, IN
WR
ITIN
G, O
F A
NY
D
ISC
RE
PA
NC
IES
BE
FOR
E P
RO
CE
ED
ING
W
ITH
WO
RK
OR
BE
RE
SP
ON
SIB
LE F
OR
SA
ME
.
I HE
RE
BY
CE
RTI
FY T
HA
T TH
ES
E P
LAN
S W
ER
E
PR
EP
AR
ED
BY
ME
OR
UN
DE
R M
Y S
UP
ER
VIS
ION
AN
D T
HA
T TH
EY
CO
MP
LY T
O T
HE
BE
ST
OF
MY
KN
OW
LED
GE
AN
D B
ELI
EF
WIT
H T
HE
R
EQ
UIR
EM
EN
TS O
F TH
E B
UIL
DIN
G C
OD
E.
2'-0" 5'-6" 5'-5" 1'-0"
5"9'-
0"10
'-7"
4'-4"
1'-7" 3'-9"
4'-5 1
/2"8'-
3"4'-
5 1/2"
1'-10"
2'-4"
7"15'
-7"
7" 7'-0" 5"
5" 13'-0"
5" 9'-0" 5" 3'-6"5" 7'-6"
1'-0"
6'-6"
7"3'-
10"
5'-8"
7"
7" 5'-10" 5" 5'-4" 1'-0"
2'-0"1'-0"
1'-0"
3'-8"
5"8'-
4"5"
3'-9"
7"13'
-0"
1'-2"
8'-2"
5" 11'-0" 5'-6" 6'-7" 1'-0"
2'-0" 5'-6" 5'-0"
7'-6"
5'-6"
1'-0"
1'-0"
26'-8" 1'-0"
27'-8"
8"8'-
3"
15'-0" 3'-10" 5" 7'-5" 1'-0"
32'-4
"
4'-0" 18'-8"
22'-8" 5'-0"
17'-2"
15'-2
"
2'-0" 5"
32'-4
"
7'-10" 5" 8'-3" 5" 9'-9"
5" 1'-2" 12'-7" 1'-0"
4'-0" 13'-9" 4'-6"
27'-8"
17'-2"
15'-2
"
5'-6" 5'-9"
2'-0" 5"
7"13'
-0"
1'-'2"
1'-0"
5'-2"
6'-5"
5'-0"
7"
5'-4" 1'-0"7" 5'-10" 5"
1'-0"
3'-8"
5"8'-
4"5"
3'-9"
5'-0"22'-8"
4'-9"
5"7'-
10"
9'-10
"3'-
2"
1'-0"
A6
R
BANQUET ROOM LEVEL FLOOR PLANSCALE 1/4"- 1'-0"
NOTE
104
A7
A6
WAIT STATION
A6 NOTECOM PLETE KITCHEN DRAWINGS TOBE S UBMIT TED FOR APPROVAL BY"TR IMARK" F OOD SERVICE EQUIPTMENT SUPPLI ES AND DESIGN
WAIT STATION105
KITCHEN103
KITCHEN
A7
NOTE
RESTAURANT LEVEL FLOOR PLAN
"B"
"B"
ENTRY
WAIT STATION
EXIST ING STAIR TO REMAIN
EXIST ING BAR IS TO REMAIN
101 102FOYER
RESTAURANT SEATING AREA
EXISTING
EXIST ING IS TO REMAIN
BAREXIST ING IS TO REMAIN
EXIST ING STAIR TO REMAIN"A"
EXIST
ING
2,500 lb.ELEVATOR
DN 22RWOOD
BAREXIST ING IS TO REMAIN
EXIST ING BAR IS TO REMAIN
BANQUET ROOMEXIST ING IS TO REMAIN
EXIST ING STAIR TO REMAIN
ALL EXI STING BE AMS AND COLUMNSARE TO REMAIN
SMOOT H FI BERG LASS ( F.R.P.) .030"LAMIN ATED TO 5/8" GYPSUM BOARD TOGO OVER THE EXISTING WALL
ALIGN NEW WALLW/ E XISTING WALL
PATCH STONEWALL AS REQUIRED
EXIST
ING S
TRUC
TURE
A6
DUCTCHASE
HOSTESS
PATCH STONEWALL AS REQUIRED
EXPOSED STONEWALL I S TO REMAIN
DUCTCHASE
EXPOSED STONEWALL I S TO REMAIN
BANQUET RM.ENTRANCE
201
FINAL PREP
204
3'-0" HIGH X 7'-0" HIGHCASE D OPENING
EXIST
ING S
TRUC
TURE
IS TO
REMA
INEXISTING
IS TO
REMA
INEX
ISTING
STR
UCTU
REIS
TO RE
MAIN
4-YARDDUMPSTERENCLOSURE
SCALE 1/4"- 1'-0"
2,500 lb.ELEVATOR
A4 A4
P
A5A5
DN 12
R
A6
1-1
LEGEND
5/8 " GYPSUM BOARD2X 4 WO OD STUDS AT 16" O.C. OR2 X 6 W OOD STUDS AT 16" O.C.5/8 " GYPSUM BOARD
5/8 " FI RECODE GYPSUM BOARD2 X 4 W OOD STUDS AT 16" O.C. OR2 X 6 W OOD STUDS AT 16" O.C.5/8 " FI RECODE GYPSUM BOARD
1 HO UR R ATED PARTITION WALLU.L. DESIGN NO. U 305
EXPANS ION JOINT
SMOOTH FIBERGLASS ( F.R.P.) .030"LAMINAT ED T O 5/ 8" GYPSUM BOARD TOGO O VER THE EXISTING WALL
PRIVATE ROOM106
COMP LETE DRAW INGS FOR THE PREP AREA ( 104 )AND DIS HWASHI NG ARE A ( 10 8 ) ARE TO BE SUBMITTEDFOR APPRO VAL BY "TR IMARK" FOOD SERVICE EQUIPTMENTSUPPLI ES AND DESIGN
PREP AREA
DISHWASHING AREA108
107CORRIDOR
( F.R. P.) .0 30" L AMINATED TO 5/8" GYPS UM BOARD TO GO OVERTHE EXI STING WALL
PRO VIDE A NE W PARTITION WALL INTHE VOI D WHERE THE DOOR WAS REMOVED
4" C ONCRETESLAB
3'- 0" HIGH METALRAILI NG SYSTEM
"B"
UP 22R
"C"
O
5'- 0" CASED OPENING IN TH E EXISTING WALL
3'-6" HIGH GUARDRAILINGSYSTEM
5'- 0" X 7'-0" CASEDOPENING
WOMEN'S TOILET RM MEN'S TOILET RM203 202
STON E IS TO B E SET BT THE MASON CONTRACTOR IN ACCORDANCEWITH SH OP AND SETTING DRAWINGS.
ALL ANCH ORS A ND ANCH ORING DEVICES SHALL BE FURNISHED BY THE MASON CON TRACT OR AS SHOWN ON THE APPROVED SHOP DRAWINGS
SMOOT H FI BERG LASS ( F.R.P.) .030"LAMIN ATED TO 5/8" GYPSIM BOARD
4" STON E TO MATCH EXISTING8" CONC RETE CLOCKDUR - O - WAL TRUSS TYPE WALLREINF ORCEM ENT AT 16" O.C.2 X 3 W OOD STUDS AT 16" O.C.2 1/2 " TH ICK EXTRUDED POLYSTYRENE RIGIDFOAMBOARD WITH A VAPOR BARRIERTO THE ROOM SIDE ( R- 13.4 )5/8 " GYPSUM BOARD
4" STON E VE NEER TO MATCH EXISTING1" A IR SPACETYV EK COM MERCIALWRAP1/2" EXTE RIOR PLYWOOD SHEATHING2 X 6 W OOD STUDS AT 16" O.C.R- 1 9 B ATT INSULATION WITH A VAPORBARR IER O N THE WARM SIDE5/8 " GYPSUM BOARD
EXIST ING STO NE WALLS ARE TO REMAIN2" X 2" W OOD FUR RING STRIPS AT 16" O.C.SMOOT H FI BERG LASS ( F.R.P.) .030"LAMIN ATED TO 5/8" GYPSUM BOARD
EXIST ING STO NE WALLS ARE TO REMAIN
"D"
UP 7R
"D"
N
K J
O
Q
M L 6" X 6" P RESSURE TREATEDWOO D P OSTS ( 3 TOTAL )COVE RED WITH WOOD 2-PIECECOLUMN
JUNE
29, 2
015
NB 0
629-
15
A - 2
107 S
tephen
St._
__Lem
ont, IL
Addit
ion to
:La
Dolc
e Vita
SH
EE
T N
o.
NB
RE
VIS
ION
SP
LAN
No.
DA
TE:
DR
AW
N B
Y:
SC
ALE
:
AP
PR
OV
ED
BY
:
n. b
atis
tich,
arc
hitec
tsM
EA
DO
WB
RO
OK
OFF
ICE
CE
NTE
R16
W4
75 S
. FR
ON
TAG
E R
D.,
SU
ITE
20
1B
UR
R R
IDG
E, I
L 6
05
27
(63
0) 9
86
-177
3
DO
NO
T S
CA
LE D
RA
WIN
GS
CO
NTR
AC
TOR
SH
ALL
VE
RIF
Y A
LL P
LAN
A
ND
DIM
EN
SIO
NS
AN
D C
ON
DIT
ION
S O
N
THE
JO
B A
ND
SH
ALL
IMM
ED
IATE
LY N
OTI
FY
THE
AR
CH
ITE
CTS
, IN
WR
ITIN
G, O
F A
NY
D
ISC
RE
PA
NC
IES
BE
FOR
E P
RO
CE
ED
ING
W
ITH
WO
RK
OR
BE
RE
SP
ON
SIB
LE F
OR
SA
ME
.
I HE
RE
BY
CE
RTI
FY T
HA
T TH
ES
E P
LAN
S W
ER
E
PR
EP
AR
ED
BY
ME
OR
UN
DE
R M
Y S
UP
ER
VIS
ION
AN
D T
HA
T TH
EY
CO
MP
LY T
O T
HE
BE
ST
OF
MY
KN
OW
LED
GE
AN
D B
ELI
EF
WIT
H T
HE
R
EQ
UIR
EM
EN
TS O
F TH
E B
UIL
DIN
G C
OD
E.
NORTH
32'-4
"
27'-8" 10"
EXIST ING 2 STORY BUILDINGW/ BASEMENT
S T E
P H
E N S
T R E
E T
T A L C O T T A V E N U E
100.00'
100.00'
32.34
'
32.34
'
20 FT.PUBLICALLEY
GUARDRAIL
TRASHENCL.
PROPOSED 2 STORY ADDITIONW/ BASEMENT
SITE PLAN SCALE : 1/16" = 1-0"
LIST OF DRAWINGS
C1 SITE PLAN
D1 DEMOLITION PL AN AND NOTES
A1 FOUNDATION AND BASEMENT PLANS
A2 RESTAURANT LEVEL AND BANQUET LEVEL FLOO R PLANS
A3 ELEVATIONS
A4 WALL SECTIONS
A5 WALL SECTIONS
A6 WALL SECTIONS
A7 WALL SECTIONS AND TOILET ELEVATIONS
A8 DOOR SCHEDULE AND ROOM FINISH SCHEDULE
S1 STRUCTURAL PLANS
S2 STRUCTURAL DETAILS
P1 PLUMBING P LAN
P2 PLUMBING DIAGRAMS AND NOTES
E1 ELECTRICAL PLAN
E2 ELECTRICAL NOTES
M1 MECHANICAL PLAN
M2 MECHANICAL NOTES
EXIT DOOR NOTETHE EGR ESS SIDE O F THE EXI T DOORS ARE TO OPERATE WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOW LEDGE , OR EFFO RT FOR OPERATION FR OM THE INSIDE OF THE BUILDING. EGRESS DOORS SHALL BEOPERABLE WIT H NO MOR E THAN ONE RE LEASI NG OP ERATION. THUMBTURN DEAD BOLTS ARE NOT PERMITTED.
ALL EXI STING EXI T DOO RS ARE TO REMAIN WITH NO CHANGES
THE NEW AD DITI ON IS TO BE E QUIPPED W ITH AN APPRO VED FIRE ALARM SYSTEM THAT SHALL BE CONNECTED TO THE EXISTING FIR E ALAR M PANE L. FIR E ALAR M SYS TEM IS T O INCLUDE PULL BOXES AT EXIT DOOR, AUDIO VISUAL FIRE ALARMSIGNALLING D EVI CES AS NE EDE D. SYS TEM IS T O BE DES IGNED IN ACCORDANCE WITH N.F.P.A. 72 CODE REQUIREMENTS.THE I NSTALLI NG CO NTRAC TOR SHALL S UBMIT PLANS T O THE LOCAL FIRE PROTECTION DISTRICT FOR APPROVAL PRIORTO INS TALLATION.
THE P LANS AND S PEC IFIC ATIONS OF THE AUTOMATIC SPRI NKLE R FOR THE NEW ADDITION SHALL BE SUBMITTED TO THE LOCALFIRE PRO TEC TION DIST RIC T FOR APPRO VAL PR IOR TO INSTALLATION BY THE INSTALLING CONTRACTOR. THE SUBMITTALSHALL BE IN ACC ORDANCE W ITH N.F .P.A. 13, CHAPTER 13.
PROVIDE AN APPR OVE D CO MPLIMENT O F 40 BC FI RE EXTINGUISHERS WITH 10 BC EXTINGUISHERS POSITIONED EVERY 50 FEET THE LOCATIONS SHALL BE APPRO VED BY THE LOCAL FIRE PROTECTION DISTRICT.
MEANS OF E GRE SS, I NCLUDI NG THE EXI T DIS CHARGE, S HALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVEDBY ME ANS OF EGR ESS IS O CCUP IED . IN T HE E VENT OF POWER FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMAT ICALLY ILLUMI NATE T HE MEANS OF E GRESS FOR NOT LESS THAN 90 MINUTES.
FIRE NOTES
ALL FLOO R FI NISHES SHALL HAVE A FLOOR SPREAD RATING OF 75 OR LESS
ALL INTE RIO R FINISHE S ON ALL EX TER IOR SURFACES ARE TO HAVE A SMOKE DEVELOPED RATING OF LESS THAN 450WHEN TEST ED I N ACCO RDANCE WITH ASTM E84.
ALL WO RK IS TO CO NFOR M TO THE REQ UIRE MENT S WI THIN C URRENT EDITIONS OF ALL LOCAL, STATE, AND FEDERAL APPLICABLECODES ADOPTED B Y THE LOCAL JURISDICTION.
EACH TRAD E SHALL BE HELD RE SPON SIBLE FOR THE KNOWLEDGE OF THE CONSTRUCTION DOCUMENTS AND THEAPPLICABLE BUILDING CODES.
ALL EXI T AND E MER GENC Y LIGHT ING AR E TO REMAIN THROUGHOUT THE BUILDING
ALL EXI STING POR TABLE F IRE EXTI NGUIS HER S ARE TO REMAIN THROUGHOUT THE BUILDING
GENERAL NOTESVER IFY ALL DI MENS IONS AND CO NDITI ONS I N THE FIELD AND NO TIFY THE ARCHITECT OF ANY DISCREPANCIES WITH THE EXISTINGBEFO RE THE CONT RACTOR PROCEEDS WITH THE WORK
ALL INTE RIO R FINISHES FOR THE W ALLS AND CEI LING ARE TO HAVE A FLAME SPREAD RATING OF 26 TO 75
THE CONT RACT OR SHALL I NCLUDE ALL OW NER FURNI SHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTORINSTALLED I TEMS IN THE CO NSTR UCTION AND SHALL COORDINATE WITH THE OWNER TO ACCOMODIATE THESE ITEMS
ALL HAZAR DOUS MATE RIALS THAT ARE STORED ON T HE PREMISES NEEDS TO PROVIDE THE AMOUNTS AND MATERIAL DATA FOR EACH
PROJECT SUMMARY TABLE
REAR 2 S TOR Y ADDIT ION PLUS A BASEMENTSCOPE OF WORK
USE GROUPGRO UP A- 2
CLASS II
FIRE SUPPRESSION/ DETECTION SYSTEM
OCCUPANT LOAD
FIRE SUPPR ESS ION / DETECTION SYSTEM / FIRE ALARM
TYPE V - B
CLASSIFICATION OF INTERIOR FINISHES
CONSTRUCTION TYPE
PROJECT LOCATION
AREA OF ALTERATIONS
107 STEPHEN S T. LEMONT, IL.
EXIS TING AR EA 6,206 SQ. FT.PROP OSE D ADDIT ION 2,434 SQ. FT.TOTAL BUILDI NG ARE A 8,640 SQ. FT.
RES TAURANT 170 OCCUPANTSKITC HEN/ D ISHW ASHING 4 OCCUPANTSSTORAGE 6 OCCUPANTSTOTAL 1 80 OCCUPANTSFINAL O CCUPANT LO AD IS TO BE POSTED
AN ADDITION TO:
107 Stephen St. Lemont, IL
La Dolce Vita
ADOPTED BUILDING CODES FOR L EMONT200 6 INT ERNATIONAL BUILDING CODE200 5 NATI ONAL ELECTRICAL CODE200 6 INT ERNATIO NAL MECHANICAL CODE201 4 ILLI NOIS PLUMBING CODE200 6 INT ERN ATIO NAL PROPERTY MAINTENANCE CODE1997 ILLINO IS ACCESSIBILITY CODE 201 2 IN TER NATIO NAL ENERGY CONSERVATION CODELEMO NT UNI FIED DEVELOPMENT ORDINANCE
CONTRACTORS USE OF THE SITEASSUME FULL R ESPO NSIBI LITY FO R PR OTE CTIO N AND SAFEKEEPING OF PRODUCTS THAT WILL BE STORED ON THE PREMISES.
THE C ONTR ACTOR SH ALL MAINT AIN ADE QUATE SER VIC E PAR KING , AND ACCESS TO THE TENANT SPACE AND THE ADJACENT SPACES.
THE CONT RACTO R SH ALL TAKE ALL PE RCAUT IONS TO PROTECT THE OWNERS PROPERTY FROM DAMAGE DURING THE PROGRESS OF THE WOR K. AN Y DAMAGE TO THE OWNE RS PROP ERT Y SHALL BE R ESTORED OR REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE ANDIN A MANN ER S ATISFACTORY TO THE OWNER.
CLEAN UPTHE P REM ISE S AND THE JO B SIT E SHALL BE M AINTAI NED I N A RE ASONABLY NEAT AND ORDERLY CONDITION, AND KEPT FREE FROMACCUMULATIO NS OF WASTE MATERI ALS AND R UBBIS H DURI NG THE ENTIRE CONSTRUCTION PERIOD. REMOVE CRATES, CARTONS,AND OT HER FLAMMABL E W ASTE MATE RIALS FRO M THE WORK AREA AT THE END OF EACH WORKING DAY.
NOTESALL EXI TS AND T HEIR CO MPONE NTS S HALL BE PRO PER LY IDE NTIFI ED BY ILLUMINATED SIGNS WITH EMERGENCY BATTERY BACKUP CAPABI LITI ES. ADDIT IONAL DEV ICE S MAY B E REQU IRE D DEP ENDING ON THE FINAL FLOOR LAYOUT. THESE SHALL BE FIELD VERIFIED.
EME RGE NCY LIGHTING UNITS SHALL BE PROV IDED FOR ALL EXI TS AND THEIR COMPONENTS THROUGHOUT THE ENTIRE SPACE. ADDITIONAL DEV ICE S MAY BE R EQU IRE D DEPENDI NG ON THE FINAL FLOOR LAYOUT. THESE SHALL BE FIELD VERIFIED.
ALL EXI T DOO RS AR E TO BE E QUIPPRD W ITH HARDWARE THAT I S EASILY OPENABLE FROM THE DIRECTION OF EXIT TRAVEL WITHOUT THE USE OF K EYS OR SPEC IAL KNOWLE DGE. ANY DE ADBOLT LOCK S MUS T BE EQUIPPED WITH THUMBTURNS ON THE INSIDE OF THE DOOR. THE HARDW ARE SHALL HAV E A S HAPE T HAT IS EASY TO G RASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWIS TING O F THE WRIST TO OPERATE.
OCC UPANT LO ADS SHALL BE POSTED
ALL RO OMS AND AREAS S HALL BE ADEQ UATELY PROTEC TED BY THE BUILDI NG'S AUTOMATIC SPRINKLER SYSTEM. CONTRACTOR SHALL SUBMIT PLANS, HYDRAUL IC C ALCULATI ONS AND CUT SHE ETS TO BOTH AGENCIES FOR REVIEW AND APPROVALS.
BUILDI NG FIR E ALAR M AND DE TEC TION SYSTEM SHALL BE UPGRADED W ITH THE PROPER NUMBER OF DEVICES. CONTRACTOR SHALL SUBMITPLANS, B ATTER Y CALC ULATIO NS, AND CUT S HEE TS TO BOTH AGENCIES FOR REVIEW AND APPROVALS.
A FIXE D EXT INGUI SHING SYS TEM SHALL BE PRO VIDED FO R ALL C OOKING SURFACES AS SPECIFIED BY THE INTERNATIONAL FIRE CODE CHAPTE R 9, NFPA ST ANDARD 96, AND U.L. 30 0. PLAN S AND C UT SHE ETS SHALL BE SUBMITTED TO BOTH AGENCIES FOR REVIEW AND APPROVAL.
A CLASS "K " PO RTABLE FIRE E XTINGU ISHE R SH ALL BE PROVIDED IN THE KITCHEN "PREP" AREA.
PORTABLE FIRE EXTI NGUISHERS WI TH A 4A60BC SHALL BE PROVIDE D AND PROPERLY HUNG WITHIN 5 FEET OF A DESIGNATED EXIT DOOR. ADDITI ONAL UNI TS MAY BE R EQU IRE D DEP ENDING ON THE FINAL FLOOR LAYOUT.
ALL ACCE SSIBLE S IGNAGE SHALL B E IN ACCO RDANC E WI TH A.N.S .I. 4 - 28 - 5 AND THE ILLINOIS ACCESSIBILITY CODE. ACCESSIBLE SIGNAGE
FIRESTOPPING NOTESSEAL ALL PENE TRATI ONS IN THE 1 HO UR R ATED F IRE BARR IER WALL AFTER INSTALLATION OF CONDUIT BOXES, ETC. WITH ANAPPRO VED FIRE- S TOP C OMPO UND. "H ILTI" FS- ONE FLEXI BLE FIRESTOP SEALANT, U.L. SYSTEM NO. W-L- 1054 OR SIMILAR.
JUNE
29, 2
015
NB 0
629-
15
C - 1
107 S
tephen
St._
__Lem
ont, IL
Addit
ion to
:La
Dolc
e Vita
Planning & Economic Development Department Form 210 1
TO: Historic Preservation Commission FROM: Adewale Adetunji, Village Intern THRU Charity Jones, AICP, Planning & Economic Development Director SUBJECT: Nomination for Registration of Historic Places DATE: November 6, 2015 SUMMARY
Staff have been working on an application to the National Register of Historic Places. While the full Lemont Historic District would not qualify for National Register listing, it appears that a portion of the current Lemont Historic District would qualify because the smaller area has enough historical integrity and is locally significant for its commercial history and as well as its full collection of commercial architecture. The purpose of nominating our historic district to the National Register is to give our property owners within the historic district financial benefits and incentives for being in the district. Owners of properties within a listed National Register district may be eligible for a 20% investment tax credit for the certified rehabilitation of income-producing certified historic structures. Federal tax deductions will also be available for charitable contributions for conservation purposes of partial interests in historically important land areas or structures. There will also be opportunities for the village to apply for federal grants for historic preservation.
Additionally, National Register listing means that state or federally permitted/ funded/ licensed projects would be required to examine alternatives before potentially damaging or destroying registered places. The following page contains a map of the area to be included in the National Register application.
Village of Lemont Planning & Economic Development Department
418 Main Street · Lemont, Illinois 60439 Phone 630-257-1595 · fax 630-257-1598
Planning & Economic Development Department Form 210 2
Now that the area for nomination in the National Register has been established, the next step in the application process is to gather information on the individual buildings within the nominated area. To clarify the exact buildings that are being nominated, the village intern recorded pictures of each building being considered. 64 buildings are currently under consideration for inclusion in the district nomination. These photographs will also be added to the application’s required photo log section. Information on the latitude and longitude will be added after receiving the information from the resources of “Google Earth”. Finally, the total area the district needs to be provided as well as a clearly defined boundary description. At the HPC meeting staff will present photos of each building to be included in the nomination package, and the corresponding historical and architectural information for each from the Granacki survey. Any additional information that the HPC can provide related to the buildings will assist staff in the application process.
Figure 1: Area Proposed for National Register Nomination