The VICOT CTF series air handler offer state-of-the-art heat transfer technology, which are designed to fit almost anywhere

and are ideal for supermarkets, hospitals, villas, residences, hotels and office buildings.

  Efficiency range from 10SEER &13SEER

  Nominal capacity from 1.5 to 5 Tons

  High quality galvanized panels ensure high corrosion resistance

  High static pressure design makes unit independent of duct system

  The evaporator uses high efficient inner screwed copper tubes and

ripple style fins, which ensures state-of-the-art heat transfer technology

  Special insulation design allows for quiet operation

  Three speed motor offers selectable airflow volume

  Advanced design allows different unique installations

  Rigorous electrical protection designed for more safety protection

  Patented diffusing equipment offers high energy efficiency.

Introduction

Features

Performance

Nomenclature

Technical Data

8/8/2019 Victor2 Air Handler

http://slidepdf.com/reader/full/victor2-air-handler 3/6

 

Shandong Vicot Air Conditioning Co.,Ltd.

 FOOTNOTES:

1. Indoor working conditioning: in cooling, temperature DB:27 ℃  (80℉ ), WB:19℃ ( 67 ℉ ) 

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters.

 As part of our continuous product improvement, Vicot reserves the right to change specifications and design without notice. 

Indoor Unit Model CTF018CN2 CTF024CN2 CTF030CN2 CTF036CN2 CTF048CN2 CTF060CN2

Outdoor Unit Model CTF018NW2 CTF024NW2 CTF030NW2 CTF036NW2 CTF048NW2 CTF060NW2

Performance Data

Nominal Cooling Capacity BTU/H 17600 22600 28600 34500 47000 55500

SEER BTU/H-W 10 10 10 10 10 10

Power / 208-230/60/1

Voltage Range / 197-253

Electric Data

Min. Operating Current A 1.9 1.9 3.4 3.4 3.9 5.9

Max. Safety Current A 10 15

Fan Motor Data

Operating Current A 2.1 2.1 3.6 3.6 4.2 6.2

Power HP 1/4 1/4 1/3 1/3 1/3 3/4

Speed High, Medium, Low

Air Outlet Dimension

Length INCH 16-5/8 16-5/8 16-5/8 16-5/8 16-5/8 19-3/4

Width INCH 11 11 11 11 11 11

Refrigerant

Type R22

Connecting Pipe Size

Liquid Pipe INCH 3/8

Gas Pipe INCH 5/8 5/8 5/8 5/8 3/4 7/8

Drain Pan Dimension INCH 3/4 3/4 3/4 3/4 3/4 3/4

Unit Size

Length INCH 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8

Width INCH 19-1/4 19-1/4 19-1/4 19-1/4 19-1/4 22-1/2

Height INCH 37-1/2 37-1/2 37-1/2 37-1/2 41-1/4 47-1/8

Ship Weight LB 108 108 115 115 142 174

Technical Data

8/8/2019 Victor2 Air Handler

http://slidepdf.com/reader/full/victor2-air-handler 4/6

 

Shandong Vicot Air Conditioning Co.,Ltd.

Indoor Unit Model CTF018CN4 CTF024CN4 CTF030CN4 CTF036CN4 CTF048CN4 CTF060CN4

Outdoor Unit Model CTF018NW4 CTF024NW4 CTF030NW4 CTF036NW4 CTF048NW5 CTF060NW5

Performance Data

Nominal Cooling Capacity BTU/H 17600  22600  28600  34500  47000  55500 

SEER BTU/H-W 10 10 10 10 10 10

Power /  220-240/50/1

Voltage Range /  198-264

Electric Data

Min. Operating Current A 1.9 1.9 3.4 3.4 3.9 5.9

Max. Safety Current A 10 15

Fan Motor Data

Operating Current A 2.1 2.1 3.6 3.6 4.2 6.2

Power HP 1/4 1/4 1/3 1/3 1/3 3/4

Speed High, Medium, Low

Air Outlet Dimension

Length INCH 16-5/8 16-5/8 16-5/8 16-5/8 16-5/8 19-3/4

Width INCH 11 11 11 11 11 11

Refrigerant

Type R22

Connecting Pipe Size

Liquid Pipe INCH 3/8

Gas Pipe INCH 5/8 5/8 5/8 5/8 3/4 7/8

Drain Pan Dimension INCH 3/4 3/4 3/4 3/4 3/4 3/4

Unit Size

Length INCH 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8

Width INCH 19-1/4 19-1/4 19-1/4 19-1/4 19-1/4 22-1/2

Height INCH 37-1/2 37-1/2 37-1/2 37-1/2 41-1/4 47-1/8

Ship Weight LB 108 108 115 115 142 174

 FOOTNOTES:

1. Indoor working conditioning: in cooling, temperature DB:27 ℃ (80℉ ), WB:19℃( 67 ℉) 

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters.

 As part of our continuous product improvement, Vicot reserves the right to change specifications and design without notice . 

Technical Data

8/8/2019 Victor2 Air Handler

http://slidepdf.com/reader/full/victor2-air-handler 5/6

 

Shandong Vicot Air Conditioning Co.,Ltd.

 FOOTNOTES:

1. Indoor working conditioning: in cooling, temperature DB:27 ℃  (81℉ ), WB:19℃ ( 67 ℉ ) 

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters

 As part of our continuous product improvement, Vicot reserves the right to change specifications and design without notice. 

Indoor unit Model CTRF 018CN2 CTRF 024CN2 CTRF 030CN2 CTRF 036CN2 CTRF 042CN2 CTRF 048CN2 CTRF 060CN2

Outdoor unit Model CTRF018AW2 CTRF 024AW2 CTRF 030AW2 CTRF 036AW2 CTRF 042AW2 CTRF 048AW2 CTRF 060AW2

Performance DataNominal Cooling

CapacityBTU/H 18500 23800 29500 36000 41000 46500 56500

SEER BTU/H-W 13 13 13 13 13 13 13

Power / 208-230/60/1

Voltage Range / 197-252

Electric Data

Min. Operating

CurrentA 2.2 2.2 3.0 3.0 3.8 3.8 3.8

Max. Safety Current A 10 15Fan Motor Data

Operating Current A 2.0 2.0 2.7 2.7 3.2 3.2 3.2

Power HP 1/2 1/2 3/4 3/4 7/8 7/8 7/8

Speed High, Medium, Low

Air Outlet Dimension

Length INCH 19-3/4 19-3/4 19-3/4 19-3/4 19-3/4 19-3/4 19-3/4

Width INCH 11 11 11 11 11 11 11

Refrigerant

Type R22

Connecting Pipe Size

Liquid Pipe INCH 3/8

Gas Pipe INCH 3/4 3/4 3/4 3/4 3/4 3/4 7/8

Drain Pan

DimensionINCH 3/4 3/4 3/4 3/4 3/4 3/4 3/4

Unit Size

Length INCH 26-1/2 26-1/2 26-1/2 26-1/2 26-1/2 26-1/2 26-1/2

Width INCH 18-7/8 18-7/8 18-7/8 22-1/2 22-1/2 22-1/2 22-1/2

Height INCH 46-7/8 46-7/8 46-7/8 46-7/8 46-7/8 46-7/8 46-7/8

Ship Weight LB 132 132 132 165 165 192 192