Vickers Filters Low, Medium & High Pressure Filters
Transcript of Vickers Filters Low, Medium & High Pressure Filters
5057.00/EN/0798/A
Low, Medium & High Pressure FiltersFlows from 23 L/min (6 USgpm) to 1135 L/min (300 USgpm)Pressures from 7 bar (100 psi) to 414 bar (6000 psi)
Vickers®
Filters
Table of Contents
General Information 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Media/Seal Kit Information 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guidelines for Selecting Filters 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specific Gravity Corrections for Pressure Drop 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viscosity Corrections for Pressure Drop 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Pressure Filters, Up to 41 bar (600 psi) 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L041 Series In Line 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L042 Series In Line 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H061 Series In Line 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HL15 Series In Tank 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HL16 Series In Tank 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HT10 Series In Tank 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HT15 Series In Tank 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OFR-15/30 Series In Line 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OFR-60/120 Series In Line 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OFRS-15 Series Spin-on 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OFRS-25 Series Spin-on 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OFRS-60 Series Spin-on 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H021/H023 Series Spin-on 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H022 Series Twin Spin-on 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OF3 Series Inlet Strainers 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10F, 50F & 100F Series Indicating Inlet Strainers 60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Medium Pressure Filters, Up to 310 bar (4500 psi) 66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H331 Series In Line 66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H340 Series In Line & Subplate 69. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H350 Series In Line 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H360 Series In Line 75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H440 Series In Line & Subplate 80. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H451 Series In Line & Subplate 83. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Pressure Filters, Up to 415 bar (6000 psi) 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H610 Series In Line & Subplate 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S610 Series Side Mount 89. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H620 Series In Line 92. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S620 Series Side Mount 95. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories 98. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
General Information
High Performance ControlVickers high performance filters aredesigned for low, medium and highpressure applications. With flows ratedto 300 gpm (1135 L/min) and pressuresrated to 6000 psi (414 bar), Vickersprovides a variety of options toimplement Systemic ContaminationControlSM in hydraulic systems.
To achieve Target Cleanliness Levels,filters are available in a wide range of:
� Port sizes
� Bypass valves
��P indicators
� Media gradesEach grade of Vickers high efficiencyfilters is thoroughly multipass tested(ISO 4572, β ≥ 200) and rated toachieve cleanliness levels inaccordance with ISO 4406. Forassistance in selecting a TargetCleanliness Level, consult AmericanNational Standard Institute ANSI(NFPA/JIC) T2.24.1-1991 or your localVickers representative.
The Systemic Approach toContamination ControlFor a hydraulic or oil lubricated machine,the development of a Target CleanlinessLevel and the plan to achieve it is asmuch a part of system design as theselection of the pump, valves, actuatorsor bearings. Proper selection andplacement of contamination controldevices in a system to attain thetargeted cleanliness eliminates (the root
cause) up to 80% of hydraulic systemfailures.
Additionally, the system cleanlinessapproach assures the user of thehydraulic system a cost effectiveapproach to contamination control thatallows the price of the filters andelements to be quickly recovered by thesavings of improved performance,increased component life, increased oillife, increased uptime and fewer repairs.
To stress the interacting relationshipbetween component design, systemdesign, filter performance and filterreplacement, Vickers has named ourapproach to filters and filtration ‘‘VickersGuide to Systemic ContaminationControlSM.’’ This approach has threesteps:
� Set a target cleanliness level.Using the Vickers Target CleanlinessWorksheet (#578), it is easy todetermine the target ISO CleanlinessLevel. This target is based on theapplication’s components and systemdynamics.
� Select filters and filter replacementsto achieve the target.The Vickers Guide to SystemicContamination Control (#561) offersoptions to consider when selecting ourhigh efficiency filters, such as theoptions available for location and sizingof filters in the system to achieve aspecified target cleanliness level.
� Monitor the system to ensure thetarget is maintained.The Vickers Fluid Analysis Laboratory
and the Target-Pro Portable ParticleCounter report the fluid cleanliness inthe three digit ISO Code Cleanlinesslevel format, corresponding to the 2, 5and 15 micron particle counts. Fromthis information, it is possible todetermine whether the system has theclean fluid it needs for long,dependable operation.
Supporting Literature� Vickers Reservoir Vent Filters
#5027/EN/0196/P
� Vickers Differential Pressure IndicatorGuide #580
� Vickers CleanCart Portable FilteringTransfer Cart #601
� Vickers Fluid Analysis Service #588
� Vickers Fluid Analysis TechnicalBrochure #664
� Vickers Guide to Alternative Fluids#579
� Vickers Recommended SamplingChart #603
� Vickers Return in Investment:ProActive Maintenance #707
� Vickers Guide to SystemicContamination Control #561
� Vickers Target Cleanliness Worksheet#578
� Vickers Target-Pro Particle Counter#709
� Vickers Water ContaminationSolutions #5026/EN/0196/A
� ANSI Systems Standards forStationary Industrial Machinery #675
� EcoPak Coreless Filter Elements#5037.00/EN/0696/A
System Cleanliness RatingsCode Typical ISO 4406
cleanliness level achieved*Number of times pumpflow passes through filter
Typical filter placements
03 14/12/1015/13/1116/14/1217/15/13
2.01.51.0.5
Full flow pressure and return lineFull flow pressure or return and recirculation loopFull flow pressure or return lineRecirculation loop sized to 10% of system vol/min
05 16/14/1217/15/1318/16/1419/17/15
2.01.51.0.5
Full flow pressure and return lineFull flow pressure or return and recirculation loopFull flow pressure or return lineRecirculaton loop sized to 10% of system vol/min
10 18/16/1419/17/1420/18/1521/19/16
2.01.51.0.5
Full flow pressure and return lineFull flow pressure or return and recirculation loopFull flow pressure or return lineRecirculation loop sized to 10% of system vol/min
* For assistance in determining the Target Cleanliness Level and selecting the proper filter element consult your local Vickers representative.
5
Media/Seal Kit General Information
Element: ProprietaryFive Layer Media
Vickers Pak ConstructionAll Vickers filter elements areconstructed with five layers, makingthem durable and highly efficient.
123
45
1. High strength support
2. Non woven synthetic diffuser layer
3. Proprietary Vickers glass micro fibermedia with special resin binder
4. Non woven synthetic diffuser(drainage) layer
5. High strength support
E-Pak ConstructionLike Vickers standard elements, E-Pakelements are constructed with fivelayers, making them durable and highlyefficient. The pleated five layers are thenenclosed by a proprietary polymer meshouter wrap to stabilize pleat spacing andsupport the entire pak under surge andinadvertent reverse flow conditions.
E-Pak elements can be crushed toreduce disposal volume by up to 60%and they can also be incinerated.
Beyond reduced disposal costs, VickersE-Pak elements are more than 50%lighter than traditional elements, makingit easier for the operator to change outelements in large filter assemblies.
The Vickers E-Pak element is actually amedia pak which slides on and off of areusable media support tube or ‘‘coretube.’’ Depending on the application, thecore tubes are either installedpermanently in the housing or they areremoved with the media pak.
H-Pak ConstructionFor systems where a bypass valve isundesirable, such as servo systems, theH-Pak media provides high collapserated housing pressures. H-Pak mediaconstruction utilizes 304 stainless steelinner and outer mesh support along withheavier core tubes and media support toprotect the system.
C-Pak ConstructionC-Pak media uses proprietary mediaand five layer construction. C-Pakincorporates epoxy coated carbon steelas the two outer face layers to retain theinner media pak layers.
R-Pak ConstructionThe R-Pak spin-on filter elements aredesigned for low clean pressure dropand high efficiency. R-Pak incorporatesa five layer media construction withouter layers of epoxy coated carbonsteel wire to retain the inner media paklayers.
L-Pak ConstructionThe L-Pak is specially designed forlubrication applications. Using the samefive layer construction as the C-Pak, theL-Pak also has a deep pleatconstruction to maximize element life insteady flow, low pulsation systems.
Seal KitsNote
Seal kits include all soft goods tofully service a unit.
Series SealType
Seal Kit Part #
041 Buna-NViton-A*
P-427466-19P-427466-21
042 Buna-NViton-A
P-427466-40P-427466-42
044 Buna-NViton-A
P-427466-43P-427466-44
061 Buna-NViton-A
P-427466-1AP-427466-3A
330/331
Buna-NViton-A
P-427466-28P-427466-30
340 Buna-NViton-A
P-427466-31P-427466-33
350 Buna-NViton-A
P-427466-1BP-427466-3B
360 Buna-NViton-A
P-427466-34P-427466-36
440 Buna-NViton-A
P-427466-22P-427466-23
450 Buna-NViton-A
P-427466-37P-427466-39
451 Buna-NViton-A
P-427466-46P-427466-48
610 Buna-NViton-A
P-427466-04P-427466-06
620 Buna-NViton-A
P-427466-10P-427466-12
HL15/HL16
Buna-NViton-A
P-233055-01P-233055-03
HT10 Buna-NViton-A
P-235876-01P-235876-03
HT15 Buna-NViton-A
P-233054-01P-233054-03
S610 Buna-NViton-A
P-427466-07P-427466-09
S620 Buna-NViton-A
P-427466-13P-427466-15
OFR60/120
Buna-NViton-A
590021 (Bowl591761 seal only)
OFR15/30
Buna-NViton-A
226214 (Bowl262422 seal only)
* Viton is a registered trademark of E.I. Dupont
Adjusted �P Housing = �P Curve x Actual SG0.9
6
Guidelines for Selecting Filters
Target CleanlinessUsing the Vickers Target CleanlinessWorksheet (#578), it is easy todetermine the target ISO CleanlinessLevel for a system. This target is basedon the application’s components andsystem dynamics.
Placement and MediaUse the chart below to help select theappropriate filter placement and grade ofmedia to achieve the target cleanlinesslevel. For more detail, consult theVickers Guide to SystemicContamination ControlSM, your Vickersrepresentative, or the ANSI SystemsStandards for Stationary IndustrialMachinery.
Filter PlacementsThe chart below helps engineers selectthe grade of Vickers media and the filterplacement(s) that will achieve therequired target cleanliness. It assumesthe system will experience ‘‘average’’ingression and that maintenance of thesystem will be consistent with currenttechnology.
If in operation the system is runningdirtier than expected, corrective actionsshould be initiated. Suggested correctiveactions are:� Check the indicator to see if the filters
are on by-pass.� Check the sources of ingression and
correct problems.� Check that the filters are positioned
properly to see maximum fluid flow.� Consider using a finer Pak grade.� Add a filter to the system.
NoteAll systems need a sealed reservoirwith vent port filtration.
CAUTIONBefore servicing theelement, the bleed plug infilter housing must be
loosened to relieve pressure. This willminimize fluid overflow.
HousingThe selected housing should be ratedwithin the required flow and pressures ofthe application.Important: If the system fluid’s specificgravity (SG) is greater than 0.9 (forexample, water glycol), the housingpressure drop (�P) should be correctedfor the actual application.
Specific Gravity Correctionsfor Pressure Drop The filter housing flow curves in this catalog can be adjusted using thefollowing equation:
Bypass ValveBypass valve selection is based uponsystem requirements. According to ANSIStandard 12.2.6, filter assemblies whoseelements cannot withstand full systemdifferential pressure without damageshould be equipped with bypass valves.Generally, a higher bypass pressuresetting will allow for longer element life.
Some systems require filtration with nobypass, such as servo applications.Vickers H-Pak media is recommendedfor non-bypass systems.
Target Cleanliness
Recommendedfilter placement forhigh ingressionsystems with fixedvolume pumps
Recommendedfilter placement forsystems with variable volumepumps
Recommendedfilter placement forhigh ingressionsystems withvariable volumepumps
Full flow pressureline or return line
Full flow pressureline and return line
Pressure line/recirculating loopat 20% of systemvolume per minute
Pressure line plusreturn line plusrecirculating loop
Recirculating loopat 20% of systemvolume per minute
Recirculating loopat 10% of systemvolume per minute
14/12/10 – 03 03 03 – –
15/13/11 – 03 03 05 – –
16/14/12 03 05 05 05 03 –
17/15/13 03 05 05 05 or 10 03 03
18/16/14 05 10 05 or 10 10 05 03
19/17/15 05 or 10 10 10 10 05 or 10 05
�
7
Indicator
To meet ANSI Standard 12.2.5, filterassemblies should have an device toindicate when the filter requiresservicing. Per ANSI Standard 12.2.6, theindicator should “trip” at approximately80% of the bypass pressure setting. Ifusing a non-bypass housing, anindicator setting of approximately 100psid is recommended. Differentialpressure indicators are rated 6000 psiworking, 3500 psi fatigue.
Thermal Lock-out
Some hydraulic filter service indicatorsare available with Thermal Lock-out(TLO). This mechanism is used insidean indicator and prevents prematureactuation due to cold start up. The TLOwill prevent actuation of an indicatorwhen the hydraulic oil is below 60�F(16�C). Once the oil reaches 100�F(38�C) and if there is still high differentialpressure, the indicator will actuate.
Surge Control
Surge control is used on systems wherespikes and surges in the hydraulicsystem could prematurely trip theindicator. Surge control slows theindicator response. If the indicatorencounters a continuous high differentialpressure, it will trip at the rated setting.
ElementThe Vickers element media gradeshould be selected to achieve the TargetCleanliness Level. The Vickers mediaconstruction should be chosen basedupon system requirements such as flowcharacteristics, pressure surges andspecific application conditions.
Important: If the system fluid’s specificgravity (SG) is greater than 0.9 (forexample, water glycol), the elementpressure drop (�P) should be corrected.
Viscosity Corrections forPressure Drop The element flow curves can be adjusted using the following equations:Adjusted Clean �PElement =
Actual viscosity in cP � 29 x �PCurveActual viscosity in cSt/32 x Actual SG � 0.9 x �PCurveActual viscosity in SUS/150 x Actual SG � 0.9 x �PCurve
A good “rule of thumb”: To ensuresatisfactory element life, the cleanelement pressure drop should generallybe less than or equal to 40 percent ofthe indicator’s rated differential pressure: �P Element � 0.4 x �P Indicator
The best way to extend element servicelife is to minimize ingression (vents,seals, cylinder rods) and maintainsystem cleanliness at or below theTarget Cleanliness Level.
Selecting a Model CodeNote
Model codes for housings onlycontain eight designations; modelcodes for filter assemblies (housingand element) contain ten designations.
To select a filter housing with theelement included, attach the ElementConstruction and Fluid CleanlinessRating designators at the end of theHousing Model Code. For example:
To select a filter housing only (with noelement), omit the Element Constructionand Fluid Cleanliness Ratingdesignators at the end of the HousingModel Code. For example:
To select a filter element only, use theElement Model Code. For example:
NoteRefer to page 99 for DifferentialPressure Indicator Selection Chart.
Indicator Switch SchematicWiring Diagram
WHITE
BLACK
GD GREEN
PINARRANGEMENT
TOSYSTEMRED
NO
NC
1 23
GD
1 2
3
C
Hirschmann (DIN 43650 Type AM) Receptacle
NoteThe female connector is to be furnishedby the customer.
NoteWhen fitting indicator, torque to 41-47Nm (30-35 lb. ft.).
WHITE
BLACK
GREEN
PINARRANGEMENT
TOSYSTEM
RED
NO
NC
1
23
GD
1
2
3
C
4
5
4
5
OR
AN
GE
Brad Harrison (41512) Receptacle
Electrical
Switch: SPDTRating: 7 amps, resistive
4 amps, inductive2 amps, lamp load@28 VDC, 115 VAC 60 Hz &220 VAC 50 Hz or 60 Hz
LO41 1 D 4 YH 1 B 2 L 05
Include
LO41 1 D 4 YH 1 B 2
VO41 1 B 2 L 05
8
LOW PRESSURE FILTERS
L041 Series Filters�Flows to 1135 L/min (300 USgpm) – Pressures to 27 bar (400 psi)
Rated flow: 284 L/min (75 USgpm)with bowl length 2568 L/min (150 USgpm)with bowl length 51135 L/min (300 USgpm)with bowl length 8
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Pressure rating: Operating 27 bar (400 psi) Proof 41 bar (600 psi) Burst 100 bar (1500 psi)
Material: Head Anodized aluminum Bowl Anodized aluminum
Dry weight: (Approximate) Bowl length 2 12,0 Kg (26.55 lbs) Bowl length 5 17,9 Kg (39.60 lbs) Bowl length 8 35,0 Kg (77.12 lbs)
Design Specifications
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Easy to grasp handle allows elementchanges without the use of tools (noloose parts).
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Anodized aluminum head/bowl/body, designed to resist corrosion.
� 2 diagnostic ports in cover plus 2 drainports in head for easy maintenance.
� High strength bypass valve assemblyfor durable, reliable performance.
� 3 bowl length options to fit in a varietyof systems.
� Replacement elements available inL-Pak or C-Pak media for highperformance to achieve targetcleanliness levels.
� Accepts Eco-Pak coreless elements.
Features and Benefits
Filter seriesL041
Port options
Valve options1 - Non-Bypass 2 - Bypass set at 22 ± 3 PSID cracking
pressure4 - Bypass set at 50 ± 5 PSID cracking
pressureNOTE: Do not use option 1 in systems withsurge pressures over 120 PSID.
D - 1.875-12UN SAE-24 str. thd. (11/2’’tube)
J - 2” SAE-4-bolt split flange Code 61K - 21/2” SAE-4-bolt split flange Code 61
Element collapse rating1 - 150 PSIDNOTE: E-Pak & L-Pak elements are rated at100 PSID collapse. If used in a Non-Bypasshousing, a monitored differential pressureindicator (70 PSID max.) should be used.(Indicator option A, B, I, U, or V)
1
2
3
4
�P indicator & receptacle optionsFirst designator (Indicator type)
A- Visual �P indicator with 70 ± 7 PSID with surge control
B- Electrical/visual �P indicator with 70 ± 7 PSID with surge control
C - Electrical/visual �P 15 ± 4 PSIDD - Electrical/visual �P 35 ± 5 PSIDE - Electrical/visual �P 100 ± 12 PSIDF - Electrical/visual �P 15 ± 4 PSID
thermal lockout (100�F)G - Electrical/visual �P 35 ± 5 PSID
thermal lockout (100�F)I - Visual �P indicator with 70 � 7
PSID thermal lockout (100� F)J - No �P indicatorK - Visual �P indicator w/ 15 ± 4 PSID
actuation & thermal lockout (100�F)L - Visual �P indicator w/ 35 ± 5 PSID
actuation & thermal lockout (100�F)M - Visual �P indicator w/ 35 ± 5 PSID,
thermal lockout (100� F) and surgecontrol
O - Visual �P indicator w/100 ± 12 PSID actuation & thermal lockout (100�F)
Q - Electrical �P switch w/15 ± 4 PSIDactuation
R - Electrical �P switch w/ 35 ± 5 PSID actuation
5
Seal materialB - Buna-N V - Viton-A
Assy. lengthmm (inch)
Element constructionC - C-Pak (grade 3, 5, 10, 20)E - E-Pak (grade 1, 3, 5, 10)
(permanent core tube installed in housing)
L - L-Pak (grade 1, 3, 5, 10, 20)
Brackets1 - No bracket(Order #P-226230-01)
Element lengthmm (inch)
Fluid cleanliness ratingsCode Target fluid
cleanliness level0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
6
7
8
9
2 - 384 (15.1) 203,2 (8) 5 - 602 (23.7) 406,4 (16)8 - 1158 (45.6) 990,6 (39)
Valve options �P indicator
Use with1 (Non–Bypass) J,E,O,T,W or Z
2 (Bypass 22 PSID) J,C,F,K,Q or X
4 (Bypass 50 PSID) J,D,G,L,M,R or Y
Housing Model Code
3 4 5 876 9 101 2
10
T - Electrical �P switch w/100 ± 12 PSID actuation
U - Electrical �P switch with 70 � 7 PSID actuation
V - Electrical/visual �P indicator with 70 �
7 PSID thermal lockout (100�F)W- Electrical/visual �P 100 � 12
PSID thermal lockout (100�F)X- Electrical/visual �P 15 ± 4 PSID
thermal lockout (100�F) & surge controlY - Electrical/visual �P 35 ± 5 PSID
thermal lockout (100�F) & surge controlZ - Electrical/visual �P 100 ± 12 PSID
thermal lockout (100�F) & surge control
Second designator (Electrical receptacle)
B - 5 pin Brad Harrison (41512)H - DIN 43650/ Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual �P
indicator only
Viton is a registered trademark of E.I. DuPont
NOTE:Order P-227533-01 for replacement aluminum indicator port plug.
9
Dimensions
Fill plug 3/4’’-16 SAE-8straight thread
Refer to model code
203,2 (8.00)Dia. max Visual differential
pressure indicator
Bleed plug 7/16’’-20SAE-4 straight thread
Inlet port
127,0 (5.00)
101,6 (4.00)typ.
Outlet port
Electrical differentialpressure indicator
1/2-13 UNC-2B thd x .75full thread (4 places)
110,2(4.34)
38,2 (1.50)61,7 (2.43)
Drain plug 3/4”-16SAE-8 Straight thread
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
0 50 100 150 200 250 3000
2
4
6
8
10
12
Flow Rate - USgpm
020
40
60
80
100
120
0
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
Pre
ssur
e dr
op –
PS
ID
50 PSID cracking
22 PSID cracking
50 100 150 200 250 300
89,0 (3.50)bolt length
222,0(8.74)
99,5(3.92)
175,0(6.89)
Dia.
193,0(7.60)
160,0(6.30)
30,0(1.18)
9,0(0.35)
Dia. bolt hole
clearance
Rubberpads(typ. 4 pls.)
3,2 (0.12) typ.
Bracket Assemblymm (inch)
L041 Housingmm (inch)
Order part numberP–226230-01
Brackets Bowl Length
1 req’d
2 req’d
3 req’d
2
5
8
15,0 (0.59)
16,5 (0.65)
50,8 (2.00)typ.
Full flow thru bypass valve
2” SAE-4-bolt split flange
11/2” SAE-24straightthread
21/2” SAE-4-boltsplit flange
Torque hand tightto seal.
CAUTIONBefore servicing theelement, the bleed plugin filter housing must be
loosened to relieve pressure. Thiswill minimize fluid overflow.
Housing Bypass Valve
�
Clearance for element removal, refer to element length.
10
041 Series Replacement Filter Elements
Rated flow: 284 L/min (75 USgpm)with bowl length 2568 L/min (150 USgpm)with bowl length 51135 L/min (300 USgpm)with bowl length 8
Housing & Compatible with mostElement petroleum oil, waterCompatability: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Construction Proprietarymedia: C-Pak, E-Pak or
L-Pak
Temperature -54�C to +135�Crange: -65�F to +275�F
Design Specifications Filter Element Flow Datamm (inch)
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
3 4 5 61 2
Element Model Code
Filter element
V041 - For use with L041 and L042series housings
Element collapse rating
1
2
Seal material
B - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
2 - 384 (15.1) 203 (8) 5 - 602 (23.7) 406 (16)8 - 1158 (45.6) 990 (39)
Element construction
Element lengthmm (inch)
C - C-Pak (grade 3, 5, 10, 20)E - E-Pak (1, 3, 5, 10)L - L-Pak (grade 1, 3, 5, 10, 20)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
0411 C-Pak element406 (16) length
Pre
ssur
e dr
op –
PS
ID
0
5
10
15
20
03051020
0 20 60 100 140 180 200
0411 C-Pak element 990 (39) length
Pre
ssur
e dr
op –
PS
ID
0
2468
0
10
100 200 30050 150 250
03051020
0411 E-Pak/L-Pak element 406 (16) length in.
Pre
ssur
e dr
op –
PS
ID
0
5
10
15
20
0 20 60 100 140 180 200
03
05
10L20
0411 E-Pak/L-Pak element 990 (39) length
Pre
ssur
e dr
op –
PS
ID
0
5
0
10
100 200 30050 150 250
030510L20
15
0411 E-Pak/L-Pak element 203 (8) length
Pre
ssur
e dr
op –
PS
ID
0
5
10
15
20
0
03
05
10
L20
20 40 60 80 100
25
0411 C-Pak element 203 (8) length
Pre
ssur
e dr
op –
PS
ID
0
5
10
15
20
0
03
051020
20 40 60Flow Rate - USgpm
80 100
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
Flow Rate - USgpm Flow Rate - USgpm
01
01
Dimensions mm (inch)
152,4 dia. typ
E-PakO-ring per AS568-239 typ.C-Pak/L-PakO-ring per AS568-243 typ.
Refer to model code
(6.00)
1 - 150 PSID (C-Pak)NOTE: E-Pak & L-Pak elements are rated at100 PSID collapse. If used in a Non-Bypasshousing, a monitored differential pressureindicator (70 PSID max.) should be used.(Indicator option A, B, I, U, or V)
L01
11
L042 Series Filters Flows to 1135 L/min (300 USgpm) – Pressures to 27 bar (400 psi)
Design SpecificationsRated flow: 568 L/min (150 USgpm)
with bowl length 51135 L/min (300 USgpm) with bowl length 8
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Pressure rating: Operating 27 bar (400 psi) Proof 41 bar (600 psi) Burst 100 bar (1500 psi)
Material: Head Aluminum alloy Bowl Aluminum alloy
Dry weight: (Approximate) Bowl length 5 98,2 Kg (216 lbs) Bowl length 8 131,8 Kg (290 lbs)
Features and Benefits� Designed to comply with ANSI
specifications and ISO cleanlinessstandards.
� Hydrostatically balanced, camoperated, positive sealing valve forlow torque shifting.
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Anodized aluminum head/bowl/body, designed to resist corrosion.
� 2 diagnostic ports in cover plus 2 drainports in head for easy maintenance.
� 2 bowl length options to fit in a varietyof systems.
� Element changes without the use oftools (no loose parts).
� Dual poppet outlet checks for positiveisolation during element replacement.
� Accepts Eco-Pak coreless elements.
Housing Model Code
3 4 5 876 91 2
Filter seriesL042
Port
Valve options1 - Non-Bypass 2 - Bypass set at 22 ± 3 PSID cracking
pressure4 - Bypass set at 50 ± 5 PSID cracking
pressureNOTE: Do not use option 1 in systems withsurge pressures over 120 PSID.
L - 3” SAE 4-bolt split flange Code 61
Element collapse rating
1
2
3
4
�P indicator & receptacle options5
Seal materialB - Buna-N V - Viton-AViton is a registered trademark of E.I. DuPont
Assy. lengthmm (inch)
Element construction
C - C-Pak (grade 3, 5, 10, 20)E - E-Pak (grade 1, 3, 5, 10)
(permanent core tube installed in housing)
L - L-Pak (grade 1, 3, 5, 10, 20)
Element lengthmm (inch)
Fluid cleanliness ratingsCode Target fluid
cleanliness level0103051020
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
6
7
8
9
5 - 574 (22.6) 406 (16)8 - 1303 (51.3) 990 (39)
Valve options �P indicator
Use with
1 (Non–Bypass) J,E,O,T,W or Z
2 (Bypass 22 PSID) J,C,F,K,Q or X
4 (Bypass 50 PSID) J,D,G,L,M,R or Y
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
1 - 150 PSIDNOTE: E-Pak & L-Pak elements are rated at100 PSID collapse. If used in a Non-Bypasshousing, a monitored differential pressureindicator (70 PSID max.) should be used.(Indicator option A, B, I, U, or V)
First designator (Indicator type)
A- Visual �P indicator with 70 ± 7 PSID with surge control
B- Electrical/visual �P indicator with 70 ± 7 PSID with surge control
C - Electrical/visual �P 15 ± 4 PSIDD - Electrical/visual �P 35 ± 5 PSIDE - Electrical/visual �P 100 ± 12 PSIDF - Electrical/visual �P 15 ± 4 PSID
thermal lockout (100�F)G - Electrical/visual �P 35 ± 5 PSID
thermal lockout (100�F)I - Visual �P indicator with 70 � 7
PSID thermal lockout (100� F)J - No �P indicatorK - Visual �P indicator w/ 15 ± 4 PSID
actuation & thermal lockout (100�F)L - Visual �P indicator w/ 35 ± 5 PSID
actuation & thermal lockout (100�F)M - Visual �P indicator w/ 35 ± 5 PSID,
thermal lockout (100� F) and surgecontrol
O - Visual �P indicator w/100 ± 12 PSID actuation & thermal lockout (100�F)
Q - Electrical �P switch w/15 ± 4 PSIDactuation
R - Electrical �P switch w/ 35 ± 5 PSID actuation
T - Electrical �P switch w/100 ± 12 PSID actuation
U - Electrical �P switch with 70 � 7 PSID actuation
V - Electrical/visual �P indicator with 70 �
7 PSID thermal lockout (100�F)W- Electrical/visual �P 100 � 12
PSID thermal lockout (100�F)X- Electrical/visual �P 15 ± 4 PSID
thermal lockout (100�F) & surge controlY - Electrical/visual �P 35 ± 5 PSID
thermal lockout (100�F) & surge controlZ - Electrical/visual �P 100 ± 12 PSID
thermal lockout (100�F) & surge control
Second designator (Electrical receptacle)
B - 5 pin Brad Harrison (41512)H - DIN 43650/ Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual �P
indicator onlyNOTE:Order P-227533-01 for replacement aluminum indicator port plug.
12
Dimensions
Filter Housing/Bypass Valve Flow Data
L042 Housingmm (inch)
Refer tomodel code
184,6(7.27)
3’’ SAE-4-bolt flangeCode 61Inlet and outlet ports
Flow
Flow
727,4 (28.64)
363,7 (14.32) 254,0(10.00)
254,0(10.00)
449,0(17.68) Ref
338,8(13.34)
110,2(4.34)
76,2(3.00)
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
020406080
100120
0Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
50 PSID cracking
22 PSID cracking
50 100 150 200 250 300
Out
In
Schematic
Housing Bypass Valve
40
30
20
10
00 50 100 150 200 250 300
3” SAE 4-boltSplit flange
127,0 (5.00) 2 places
63,5 (2.50) 2 places
Flow12,7 (0.50) 2 places
Flow254,0(10.00)
Support leg 2 places
Mounting holes1/2–13 UNC–2B x .75 min.full thd. 4 places
254,0(10.00)
Torque hand tightto seal.
13
041 Series Replacement Filter Elements
152,4 dia. typ
Rated flow: 568 L/min (150 USgpm)with bowl length 51135 L/min(300 USgpm) with bowl length 8
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Construction Proprietarymedia: C-Pak, E-Pak or
L-Pak construction
Temp range: - 54�C to +135�C(- 65�F to +275�F)
E-PakO-ring per AS568-239 typ.C-Pak/L-PakO-ring per AS568-243 typ.
Design Specifications Filter Element Flow Datamm (inch)
Element Model Code
Filter element
V041 - For use with L041 and L042series housings
Element collapse rating
1
2
Seal material
B - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
3
Assy. lengthmm (inch)
5 - 574 (22.6) 406 (16)8 - 1303 (51.3) 990 (39)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
3 4 5 61 2
0411 C-Pak element406 (16) length
Pre
ssur
e dr
op –
PS
ID
0
5
10
15
20
03
051020
0 40 80 120Flow Rate - USgpm
160 200
0411 C-Pak element990 (39) length
Pre
ssur
e dr
op –
PS
ID
0
2
468
0
10
100 200 30050 150 250
03
051020
0411 E-Pak/L-Pak element406 (16) length
Pre
ssur
e dr
op –
PS
ID
0
5
10
15
20
0 40 80 120 160 200
03
05
10L20
0411 E-Pak/L-Pak element 990 (39) length
Pre
ssur
e dr
op –
PS
ID
0
5
0
10
100 200 30050 150 250
030510L20
15
C - C-Pak (grade 3, 5, 10, 20)E - E-Pak (grade 1, 3, 5, 10)L - L-Pak (grade 1, 3, 5, 10, 20)
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
Flow Rate - USgpm
Flow Rate - USgpm
Flow Rate - USgpm
01
01Dimensions mm (inch)
Refer to model code
(6.00)
1 - 150 PSID (C-Pak)NOTE: E-Pak & L-Pak elements are rated at100 PSID collapse. If used in a Non-Bypasshousing, a monitored differential pressureindicator (70 PSID max.) should be used.(Indicator option A, B, I, U, or V)
14
H061 Series Filters Flows to 189 L/min (50 USgpm) – Pressures to 41 bar (600 psi)
Design Specifications
Features and Benefits Housing Model Code
Rated flow: 95 L/min (25 USgpm)with bowl length 1189 L/min (50 USgpm)with bowl length 2378 L/min (100 USgpm)with bowl length 4
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Pressure rating: Operating 41 bar (600 psi) Proof 62 bar (900 psi) Burst 100 bar (1500 psi) Fatigue 41 bar (600 psi)
per NFPA T2.6.1
Material: Head Cast iron Bowl Steel
Dry weight: (Approximate) Bowl length 1 3,6 Kg (7.90 lbs) Bowl length 2 4,0 Kg (8.90 lbs) Bowl length 4 4,6 Kg (10.20 lbs)
Meets or exceeds HF3 filter elementspecifications when used with bowllength 2.
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Conforms to HF3 specifications (#2bowl length).
� Diagnostic port in head for pressuresensing and fluid sampling flexibility.
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Fully serviceable without tools.
� Plated nodular iron head and steelbowl (deep drawn) for durability andcorrosion resistance.
� Bypass valve with steel body andpolymer soft seat construction forzero-leak bypass.
� Replacement elements available inC-Pak media for high performance toachieve Target Cleanliness Levels.
� High collapse H-Pak element availablefor use in non-bypass applications.
� Accepts Eco-Pak coreless elements.
3 4 5 876 91 2
Filter seriesH061
Port options
Valve options1 - Non-Bypass 3 - Bypass set at 22 ± 3 PSID cracking
pressure4 - Bypass set at 50 ± 5 PSID cracking
pressureNOTE: Use option 1 only with 600 psid collapsefilter element.
A - 1.062-12UN SAE-12 str. thd. (3/4’’ tube)
B - 1.312-12UN SAE-16 str. thd. (1” tube)
Element collapse rating1 - 150 PSID3 - 600 PSID (H-Pak only)
NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1
2
3
4
�P indicator & receptacle optionsFirst designator (Indicator type)
C - Electrical/visual �P 15 ± 4 PSIDD - Electrical/visual �P 35 ± 5 PSIDE - Electrical/visual �P 100 ± 12 PSIDF - Electrical/visual �P 15 ± 4 PSID
thermal lockout (100�F)G -Electrical/visual �P 35 ± 5 PSID
thermal lockout (100�F)J - No �P indicatorK - Visual �P indicator w/ 15 ± 4 PSID
actuation & thermal lockout (100�F)L - Visual �P indicator w/ 35 ± 5 PSID
actuation & thermal lockout (100�F)M - Visual �P indicator w/ 35 ± 5 PSID,
thermal lockout (100� F) and surgecontrol
O -Visual �P indicator w/100 ± 12 PSID actuation & thermal lockout (100�F)
P - Visual �P indicator w/100 ± 12PSID actuation & thermal lockout(100�F) & surge control
Q - Electrical �P switch w/15 ± 4 PSIDactuation
R - Electrical �P switch w/ 35 ± 5 PSID actuation
T - Electrical �P switch w/100�12 PSID actuation
5
Seal materialB - Buna-N V - Viton-AViton is a registered trademark of E.I. DuPont
Assy. lengthmm (inch)
Element constructionC - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5, 10)
(permananet core tube installed inhousing)
H - H-Pak 600 PSID collapse(grade 3, 10)
Element lengthmm (inch)
Fluid cleanliness ratings
CodeTarget fluid cleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
7
8
9
1 -185,4 (7.3) 101 (4)2 - 276,8 (10.9)* 203 (8)*4 - 398,3 (15.6) 330 (13)*HF3
Valve options �P indicator
Use with
1 (Non–Bypass) J,E,O,P,T,W or Z
3 (Bypass 22 PSID) J,C,F,K,Q or X
4 (Bypass 50 PSID) J,D,G,L,M,R or Y
W- Electrical/visual �P 100 � 12 PSID thermal lockout (100 �F)
X- Electrical/visual �P 15 ± 4 PSIDthermal lockout (100�F) & surge control
Y - Electrical/visual �P 35 ± 5 PSIDthermal lockout (100�F) & surge control
Z - Electrical/visual �P 100 ± 12 PSIDthermal lockout (100�F) & surge control
Second designator (Electrical receptacle)
B - 5 pin Brad Harrison (41512)H - DIN 43650/ Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual �P
indicator only
NOTE:Order P-227533-01 for replacementaluminum indicator port plug.
6
S50 -Head sub-assembly only (No element, bowl or indicator)
15
Dimensions
Filter Housing/Bypass ValveFlow Data
061 Housingmm (inch)
0 20 40 600
2
4
6
8
10
12
Flow Rate - USgpm
22 PSID cracking
50 PSID cracking
010
20
30
40
50
60
0 10 20 30 40 50 60Flow Rate - USgpm
10 30 50
Pre
ssur
e dr
op –
PS
ID
Pre
ssur
e dr
op –
PS
ID
122,7(4.83)
123,2(4.85)
15,9(0.62)
89,7(3.53)max.
35,0(1.38)Max.
26,9(1.06)
38,1 (1.5) min. req’d. forelement & bowl removal
Refer to model code
Bleed plug7/16-20 SAE-4 straight thread
Out In
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
�P indicator
33,5 (1.32)
28,6(1.12)
57,2 (2.25 )
5/16 -18 UNC-3Bthd. mtg. hole(2 places)
InletOutlet 31,8 (1.25)
3/4” SAE-12Str. thd.
Housing Bypass Valve
1” SAE-16Str. thd.
Torque bowl to 15 lb. ft(20 Nm) max.
CAUTIONBefore servicing theelement, the bleed plugin filter housing must be
loosened to relieve pressure. Thiswill minimize fluid overflow.
63,5(2.50)29,9 (1.18)
35,0 (1.38)
Visual: 44,4 (1.75) max.Elec: 71,1 (2.80) max.
�
16
602 Series Replacement Filter Elements
Rated flow: 95 L/min (25 USgpm)with bowl length 1189 L/min (50 USgpm)with bowl length 2378 L/min (100 USgpm)with bowl length 4
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Construction Proprietary & media: C-Pak, E-Pak or H-Pak
E-PakO-ring perAS568-135C-Pak/H-PakO-ring perAS568-131
Design specifications Filter Element Flow Datamm (inch)
Dimensionsmm (inch)
Element Model Code
Filter element
V602 - For use with 061, 350, 620 &OFR30 series filters
Element collapse rating1 - 150 PSID3 - 600 PSID (H-Pak)
1
2
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
Meets or exceeds HF3 filter elementspecifications when used with bowllength 2.
0
10
20
0 10 20 30Flow Rate - USgpm
5 15 25 35 40
30
Pre
ssur
e dr
op –
PS
ID
03
0510
C20
6021 C-Pak/E-Pak element101 (4) length
0
10
20
0 20 40 6010 30 50 70 75
30
Pre
ssur
e dr
op –
PS
ID
03
0510
C20
6021 C-Pak/E-Pak element203 (8) length
3 4 5 61 2
NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1 - 185,4 (7.3) 101 (4)2 - 276,8 (10.9)* 203 (8)*4 - 398,3 (15.6) 330 (13)* HF3
C - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5, 10)H - H-Pak (grade 3, 10)
0
10
20
0 20 40 60
30
Pre
ssur
e dr
op –
PS
ID
03
0510
C20
6021 C-Pak/E-Pak element330 (13) length
80 100 120
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
Flow Rate - USgpm
Flow Rate - USgpm
C01
C01Refer tomodelcode
79,8(3.14)dia. typ
1,27 (0.05 ) max.
6023 H-Pak element 101 (4) length
6023 H-Pak element 203 (8) length
6023 H-Pak element 330 (13) length
Pre
ssur
e dr
op –
PS
IDP
ress
ure
drop
– P
SID
Pre
ssur
e dr
op –
PS
ID
01020
30
40
0 10 20 305 15 25 35 40
50 03
10
0
1020
304050
5 15 25 35 45 55 65 750
03
10
010203040
0 40 80 12020 60 100
5003
10
Flow Rate - USgpm
Flow Rate - USgpm
Flow Rate - USgpm
17
HL15 Series Filters Flows to 189 L/min (50 USgpm) – Pressures to 14 bar (200 psi)
Design Specifications
Features and Benefits Housing Model Code
Filter seriesHL15
Port options
Element collapse rating
1 - 150 PSID
1
2
3
4
3 4 5 876 91 2
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Available with C-Pak media for highperformance to achieve targetcleanliness levels.
� Conforms to HF4 specifications.
� Quick disconnect cover for easyservicing (no loose parts).
� Optional second inlet port allowsadditional return line or prefilteringof new oil.
� Optional reservoir mounting weldflange.
� Optional electrical pressure switch orpressure gauge allows designflexibility.
� Two pressure gauge ports allowflexibility in locating gauges.
� Small size convenient for mobile orspace confined applications.
Meets HF4 specifications
Dry weight: (Approximate) Bowl length 3 2,3 Kg (5.25 lbs) Bowl length 9 2,8 Kg (6.25 lbs) (w/ 12” extension tube)
Temp range: -32�C to +135�C (–25�F to +275�F)
Pressure rating: Operating 14 bar (200 psi )
Material:Head AluminumCover AluminumBowl Carbon steel
10
D - 1.875-12UN SAE-24 straight thread (11/2’’ O.D. tube)
E - 11/2” SAE 4-bolt split flange Code 61
3 - Bypass set at 25 � 3 PSIDcracking pressure
4 - Bypass set at 50 � 5 PSIDcracking pressure
Valve bypass setting
5 Indicator type
1 - No indicator2 - 0 to 200 psi pressure gauge4 - 0 to 60 psi pressure gauge, color
coded6 - Electrical switch, 18 psi - Brad
Harrison7 - Electrical switch, 35 psi - Brad
Harrison8 - Electrical switch, 18 psi - DIN 436509 - Electrical switch, 35 psi - DIN 43650(See page 7 for wiring diagram.)
6 Assy.lengthmm (inch)
3 - 193,5 (7.62) 229 (9)9 - 193,5 (7.62) with 229 (9)
305 (12) extension tubeS50 - Head sub-assembly only (no
element, bowl or indicator)
Elementlengthmm (inch)
Secondary port option
T - 1.875-12UN SAE-24 straight thread (11/2’’ O.D. tube)
Z - 11/2” SAE-4-bolt split flangeCode 61
N - No secondary port
Seal material
B - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Element construction
Fluid cleanliness ratings
Code Target fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
7
8
9
10
C - C-Pak (grade 01, 3, 5, 10, 20)
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
Rated flow: 189 L/min (50 USgpm)
Bypass
3 1, 4, 6, 84 1, 2, 7, 9
Indicator Selection GuideIndicator
18
Dimensions
Filter Housing Flow Data
HL15 Housingmm (inch)
Optional secondinlet port
170,2(6.70)
∅ 180,3(7.10)
49,3(1.94)
Gauge port 1/8 NPTFplugged 2 places
105,4(4.15)
11,2(0.44)
A
B
D
C
∅ 40,0 (1.58)**∅ 110,5 (4.35)∅ 125,7 (4.95)
** Set up for SAE-24 100RS hose
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
2
4
6
20 40 6010
Element bowl lengthmm (inch)
ModelCode A B C D
193,5(7.62)
329,4(12.97)
30,5(1.20)3
9 193,5(7.62)
329,4(12.97)
307,9(12.12)
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
Electrical switch (18 psi) Brad Harrison P-234117-01�Electrical switch (35 psi) Brad Harrison P-234118-01�Electrical switch, (18 psi) DIN
P-233051-01�Electrical switch, (35 psi) DIN
P-233573-01�Gauge, (0-60 psi*) (Color coded)
P-232965-01�Gauge, (0-200 psi) P-232974-01�Weld flange P-232964-01�*For use with 25 psi bypass only� See page 97 for electrical switch installation.� See page 97 for gauge installation.� See page 97 for weld flange installation.
Accessories
0.44 Dia. holes (4) equallyspaced on a 6.25 dia. bolt circle.7/16-20 UNF Grade 8 bolts (4)recommended.
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
60
40
20
010 20 30 40 500
Bypass Valve
50 PSID Valve
25 PSID Valve
80
25
50
19
405 Series Replacement Filter Elements
Construction Proprietary & media: C-Pak
Temp range: -32�C to +135�C (-25�F to +275�F)
Meets HF4 filter specifications
Design Specifications Filter Element Flow Datamm (inch)
Dimensions mm (inch)
Element Model Code
Filter element
V405 - For use with HL15, OFR60 &H451
Element collapse rating1 - 150 PSID
1
2
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
3 4 5 61 2
100,3 dia. typ(3.95)
Refer tomodel code
4051 C-Pak 229 (9) length
0
2
4
6
0Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
5 10 15 20 25 30 35 40 45 50
8
10
1203
0510
20
3 - 203 (8) 229 (9)
C - C-Pak (grade 01, 3, 5, 10, 20)
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
01
Rated flow: 189 L/min (50 USgpm) (9” element)
20
HL16 Series Filters Flows to 568 L/min (150 USgpm) – Pressures to 14 bar (200 psi)
6
Design Specifications
Features and Benefits Housing Model Code
Filter seriesHL16
Port options
Element collapse rating
1 - 150 PSID
1
2
3
3 4 5 876 91 2
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Conforms to HF4 specifications.
� Available with C-Pak media for highperformance to meet targetcleanliness code.
� Quick disconnect cover for easyservicing (no loose parts).
� Optional second inlet port available foran additional return line connection orprefiltering new oil.
� Optional reservoir mounting weldflange available.
� Optional with electrical pressureswitch or pressure gauge for designflexibility.
� Two pressure gauge ports allowsflexibility in locating gauges.
� Accepts Eco-Pak coreless elements.
Meets HF4 specifications with stacked9 inch elements
10
D - 1.875-12UN SAE-24 straight thread (11/2’’ O.D. tube)
E - 11/2” SAE 4-bolt split flange Code 61
Secondary port option
T - 1.875-12UN SAE 24 straight thread (11/2’’ O.D. tube)
Z - 11/2” SAE 4-bolt split flangeCode 61
N - No secondary port
Seal material
B - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Element construction
Fluid cleanliness ratings
Code Target fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
7
8
9
10
Dry weight: (Approximate) Bowl length 6 7,3 Kg (16 lb) Bowl length 7 10,4 Kg (23 lb)
Temp range: –32�C to +135�C(–25�F to + 275�F)
Pressure rating: Operating 14 bar (200 psi)
Material:Head AluminumCover AluminumBowl Carbon steel
6 - 431,8 (17.0) 457 (18)7 - 670,1 (26.4) 685 (27)
C - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5, 10)
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
4
3 - Bypass set at 25 � 3 PSIDcracking pressure
4 - Bypass set at 50 � 5 PSIDcracking pressure
Valve bypass setting
5 Indicator type
1 - No indicator2 - 0 to 200 psi pressure gauge4 - 0 to 60 psi pressure gauge, color
coded6 - Electrical switch, 18 psi - Brad
Harrison7 - Electrical switch, 35 psi - Brad
Harrison8 - Electrical switch, 18 psi - DIN 436509 - Electrical switch, 35 psi - DIN 43650(See page 7 for wiring diagram.)
Assy.lengthmm (inch)
Elementlengthmm (inch)
Rated flow: 379 L/min (100 USgpm) (When used with bowl length 6)
568 L/min (150 USgpm)(When used with bowl length 7)
Bypass
3 1, 4, 6, 84 1, 2, 7, 9
Indicator Selection Guide
Indicator
S50 – Head sub-assembly only (Noelement, bowl or indicator)
21
Dimensions
Refer to model code forport options
Interfacegasket(furnished)
Filter Housing/Bypass Valve Flow Data
HL16 Housingmm (inch)
20 40 60 80 100 120 1400
2
4
6
8
10
0Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
12
14
mm (inch)
6 431,8 (17.00)7 670,1 (26.38)
105,4(4.15)
∅ 117,6 (4.63)
49,3(1.94)
170,2(6.70)
11,2(0.44)
∅ 180,3(7.10)
Optional secondinlet port
11,2 (0.44) dia.4 holesequally spacedon 6.25 boltcircle
1-1/2” NPTmalepipe adapter
∅ 177,8(7.00)
4 bolts 7/16-20 UNF
21,8(0.86)
Gauge port 1/8NPTF plugged2 places
Refer to table.
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
Accessories
Element Bowl Length
ModelCode
Length
Electrical switch (18 psi) Brad Harrison P-234117-01�Electrical switch (35 psi) Brad Harrison P-234118-01�Electrical switch, (18 psi) DIN
P-233051-01�Electrical switch, (35 psi) DIN
P-233573-01�Gauge, (0-60 psi*) (Color coded)
P-232965-01�Gauge, (0-200 psi) P-232974-01�Weld flange P-232964-01�*For use with 25 psi bypass only� See page 97 for electrical switch installation.� See page 97 for gauge installation.� See page 97 for weld flange installation.
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
60
40
20
0500
Bypass Valve
50 PSID Valve
80
25
50
100 150
25 PSID Valve
Housing
22
405 Series Replacement Filter Elements
Construction Proprietary & media: C-Pak or E-Pak
Temp range: -32�C to +135�C(-25�F to +275�F)
Meets HF4 filter specifications withstacked 9 inch elements.
Design specifications Filter Element Flow Datamm (inch)
Dimensions mm (inch)
Element Model Code
Filter element
V405 - For use with OFR120, HL16 &H451
Element collapse rating1 - 150 PSID
1
2
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
C - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5, 10)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
3 4 5 61 2
100,3 dia. typ(3.95)
Refer tomodel code)
6 - 431,8 (17.0) 457 (18)7 - 670,1 (26.4) 685 (27)
4051 E-Pak/C-Pak 457 (18) length
0
2
4
6
0Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
10 20 30 40 50 60 70 80 90 100
8
1012
03
0510
C20
4051 E-Pak/C-Pak 685 (27) length
0
2
46
Flow Rate - USgpm
8
10
12
20 40 60 80 100 120 140
03
0510
C20
Pre
ssur
e dr
op –
PS
ID
0
Replacement Element ConnectorVickers 457 mm (18 inch) and 685 mm (27 inch)elements are single elements. This eases handling andelement replacement.
228 mm (9 inch) elements may be stacked rather thanusing one longer element.
Order P-227567-01 replacement element connector whenstacking 228 mm (9 inch) elements.
Removable core kits for Eco-Pak:18” for bowl length 6 PH451R6BN27” for bowl length 7 PH451R7BN
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
C01
C01
Rated flow: 379 L/min (100 USgpm) (When used with bowl length 6)
568 L/min (150 USgpm)(When used with bowl length 7)
E-Pak O-ringper AS568-135
23
HT10 Series Filters Flows to 38 L/min (10 USgpm) – Pressures to 7 bar (100 psi)
9
8
71
2
3
6
5
Design Specifications
Features and Benefits Housing Model Code
Filter seriesHT10
Port
Element collapse rating
1 - 150 PSID
4
3 4 5 876 91 2
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Available with C-Pak media.
� C-Pak media includes strong epoxybonding and inner and outer steelmesh for increased element reliability.
� Optional reservoir mounting weldflange available.
� Optional with electrical pressure switchor pressure gauge allows designflexibility.
O - 3/4--16 UNF SAE-8 straight thread (1/
2” tube)
3 - Bypass set at 25 � 3 PSID cracking pressure
Valve bypass setting
Indicator type
Bowllengthmm (inch)
1 - 60.7 (2.39) 70 (2.75)
Elementlengthmm (inch)
C - C-Pak (grade 3, 5, 10, 20)
Seal material
B - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Element construction
Fluid cleanliness ratings
Code Target fluidcleanliness level
03051020
16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
Dry weight: (Approximate)0,43 kg (0.95 lbs.)
Rated flow: 38 L/mim (10 USgpm)
Temp range: -32�C to +135�C(- 25�F to +275�F)
Material:Head AluminumCover AluminumBowl Steel
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
1 - No indicator4 - 0 to 60 psi pressure gauge,
color coded6 - Electrical switch, 18 psi - Brad
Harrison8 - Electrical switch, 18 psi – DIN 43650
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
Pressure rating:Operating 7 bar (100 psi)
24
Dimensions
Filter Housing Flow Data
HT10 Housingmm (inch)
0
1.0
2.0
0Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
3 6 9 12
3.0
4.0
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
105,1 (4.14)
1/8” NPT (Gauge port plugged)
�7,1 (0.28) Located on89,9 (3.54) BC2 places
�82,8 (3.26)
16,8 (0.66)
32,3 (1.27)
3/4-16 UNF SAE-8thread (1/2” tube)
22,1 (0.87)
7,6 (0.30)
47,2 (1.86)
107,9 (4.25)
132,6 (5.22)
�23,9 (0.94)
�59,7 (2.35)
�65,8 (2.59)
1/4-20 UNF Screw3 places
AccessoriesElectrical switch (18 psi)� Brad Harrison P-234117-01�Electrical switch, (18 psi) DIN�
P-233051-01�Gauge, (0-60 psi) (Color coded)
P-232965-01�Weld flange P-235421�� See page 97 for electrical switch installation.� See page 97 for gauge installation.� See page 97 for weld flange installation.� Customer to furnish mating connector.
25
VT10 Series Replacement Filter Elements
Design Specifications Filter Element Flow Data
Dimensions mm (inch)
Element Model Code
Filter element
VT10 - For use with HT10 series filters
Element collapse rating1 - 150 PSID
1
2
Seal material3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
C - C-Pak (grade 3, 5, 10, 20 )
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
03051020
16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
3 4 5 61 2
0
4
12
16
0
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
4 10
20
8
03
05
10
20
N - Element does not contain seals
1 - 60,7 (2.39) 70 (2.75)
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for specific gravity corrections for pressure drop.)
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
Rated flow: 38 L/min (10 USgpm)
Temp range: -32�C to +135�C(- 25�F to +275�F)
Construction Proprietary& media: C-Pak
862
50,0 (2.0)
70,0 (2.75)
26
HT15 Series Filters Flows to 76 L/min (20 USgpm) – Pressures to 7 bar (100 psi)
Design Specifications
Features and Benefits Housing Model Code
Filter seriesHT15
Port
Element collapse rating
1 - 150 PSID
1
2
3
4
3 4 5 876 91 2
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Available with C-Pak media.
� Quick disconnect cover for easyservicing.
� Optional reservoir mounting weldflange available.
� Optional with electrical pressure switchor pressure gauge allows designflexibility.
A - 1.062-UN SAE-12 straight thread (3/4’’ O.D. tube)
3 - Bypass set at 25 � 3 PSID cracking pressure
Valve bypass setting
5 Indicator type
6
Assy.length
1 - 121,0 (4.76) 130,0 (5.1)
Elementlength
mm (inch) mm (inch)
C - C-Pak (grade 3, 5, 10, 20)
Seal material
B - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Element construction
Fluid cleanliness ratings
Code Target fluidcleanliness level
03051020
16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
7
8
9
Dry weight: (Approximate)1,1 Kg (2.35 lbs)
Rated flow: 76 L/mim (20 USgpm)
Temp range: -32�C to +135�C(- 25�F to +275�F)
Material:Head AluminumCover AluminumBowl Steel
NOTE: Bypass valve is an integral part of theelement and is set at 25 ± 3 psid crackingpressure.
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
1 - No indicator4 - 0 to 60 psi pressure gauge,
color coded6 - Electrical switch, 18 psi - Brad
Harrison8 - Electrical switch, 18 psi - DIN 43650(See page 7 for wiring diagram.)
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
Pressure rating:Operating 7 bar (100 psi)
S50 -Head sub-assembly only (No element, bowl or indicator)
27
Dimensions
Filter Housing Flow Data
HT15 Housingmm (inch)
Accessories
0
3
6
9
0Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
5 10 15 20 25 30
12
15
17
29,5(1.16)
9,38(0.37)
67,0(2.64)
Gauge port1/8” NPTF plugged 2 places
69,1(2.72)
∅ 28,2 (1.11)**
∅ 139,7 (5.50)
136,1(5.36)
∅ 88,9 (3.50)
∅ 89,0 (3.11)
190.0(7.48)
220,4(8.68)
SAE-12 O-ring port1-1/16-12 thread nominal tube O.D. 3/4Inlet
8,9 (0.35) dia.located on 4.70BC (2 places)
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
Electrical switch (18 psi)� Brad Harrison P-234117-01�Electrical switch, (18 psi) DIN�
P-233051-01�Gauge, (0-60 psi) (Color coded)
P-232965-01�Weld flange P-333637�� See page 97 for electrical switch installation.� See page 97 for gauge installation.� See page 97 for weld flange installation.
� Customer to furnish mating connector.
Outlet
**Set-up for SAE-20100RS hose or push-on
28
VT15 Series Replacement Filter Elements
Design Specifications Filter Element Flow Data
Dimensions mm (inch)
Element Model Code
Filter element
VT15 - For use with HT15 series filters
Element collapse rating1 - 150 PSID
1
2
Seal material3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
C - C-Pak (grade 3, 5, 10, 20 )
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
03051020
16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
3 4 5 61 2
0
5
10
15
0Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
5 10 15 20 25 30
20
25
30
03
0510
20
69,2(2.73)
133,3(5.25)
NOTE: Bypass valve is an integral part of theelement and is set at 25 + 3 psid crackingpressure.
V - Viton-A (Standard)Viton is a registered trademark of E.I. DuPont
1 - 121,0 (4.76) 130,0 (5.1)
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for specific gravity corrections for pressure drop.)
This table assumes limited ingression/single pass of pump flow through theelement. For detailed assistance,consult Vickers Guide to SystemicContamination Control or contact yourlocal Vickers Distributor.
Rated flow: 76 L/mim (20 USgpm)
Temp range: -32�C to +135�C(- 25�F to +275�F)
Construction Proprietary& media: C-Pak
29
OFR-15/30 Series Filters Flows to 114 L/min (30 USgpm) – Pressures to 41 bar (600 psi)
Features and Benefits� OFR-30 conforms to HF3
specifications.
� Two bowl length options.
� Flows to 30 USgpm.
� Visual indicator is standard.
� Electrical indicator also available.
� Bypass valve is standard.
� Replacement elements available inC-Pak or single layer construction.
� Accepts Eco-Pak coreless elements.(OFR30 only)
Design SpecificationsRated flow: OFR15 57 L/min (15 USgpm) OFR30 114 L/min (30 USgpm)
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.
Temp range: -40�C to +107�C(-40�F to +225�F)
Pressure rating: Operating 41 bar (600 psi)
Element 100 psidcollapse rating:
Standard bypass valve setting:25 � 4 psid
Material: Head Die cast aluminum Bowl Carbon steel
Dry weight: (Approximate) OFR15 4,1 kg (9 lbs. OFR30 5,4 kg (12 lbs.)
General DataThese filters are designed for use in thereturn lines of hydraulic systems. Theyremove particulate contaminants fromthe system fluid, thus improvingperformance and reliability of the systemcomponents while extending theirservice life. A bypass valve andmechanical visual indicator arestandard.
Bypass ValveAn internal relief valve parallels theelement to limit the pressure drop acrossthe element. The valve is set to open at25 PSID as standard.
Filter ElementsThese return line filters are offered inC-Pak media and in single layer media.
The C-Pak media has been designedto meet the requirements of VickersSystemic Contamination Controlprogram and are available in 3, 5, 10and 20 micron (99% efficient) ratings.To learn more on this program, consultVickers brochure. Replacementelements for C-Pak are ordered bymodel code.
In some systems, the single layermedia may offer an alternative. Theseare available in 15, 25 and 50 micron(99% efficient) ratings.
Refer to the model code page forfurther information on filter elementsand cleanliness ratings.
IndicatorsMechanicalA rotary type indicator is mechanicallyassociated with the bypass valve andindicates the condition of this valve.Visible through the transparentwindows in the protecting hood, theindicator will show green for a closedbypass valve and progressively showyellow for a warning that the elementpressure drop is getting into the dangerzone and red for an open bypassvalve. By removing the protecting hoodand reassembling the rotary indicator180 on its stem, the indicator nowprovides a “memory” in that it rotates tothe maximum opening of the bypassand remains in this position untilmanually returned by rotation of theknurled projecting knob.
ElectricalA lever actuated electrical switch ismounted in the enclosure. An actuatormounted to the bypass valvedepresses the switch just prior to theopening of the bypass valve to changethe completion of the electrical switchcircuit from the common and thenormally closed terminals to thecommon and normally open terminals.
The 1/2 inch pipe tap is provided forconnection to external conduit andlengths of color coded wires aresoldered to the switch terminals forconnection to the external circuit throughthe wires in the conduit. The switchcontacts are rated for 5 amperesresistive loading up to 250 Vac.
System PressureThe housing is suitable for greater than10 million pressure pulsations from 0 to600 psi.
Mounting PositionAny mounting position is permitted.Vertical is preferred from a servicingstandpoint.
PortsStraight thread ports accept the SAEfittings. Flange ports accept the 4-boltSAE flange.
Straight thread connections providesuperior external leakage protection inapplications having pulsating pressuresor system vibrations.
Fluids and SealsHydraulic oils, water glycols andwater-in-oil emulsions can be filteredwith the standard unit.
Soluble oil in water fluids can also befiltered with the standard unit if the fluidpH does not exceed 8.5. A higher pHthan this has an adverse effect on thealuminum components.
Synthetic fluids require special sealswhich can be obtained by prefixing themodel number with “F3”.
Refer to Vickers ‘‘Hydraulic Hints &Troubleshooting Guide’’ #694 forhydraulic fluid and temperaturerecommendations.
30
Performance Curves
25
7G
30
0 10 20 30 40 500
1
2
3
4
5
6
7
OFR-30
OFR-15
10 20 30 40 50 60 70 80 90 100 110 120
5101520
35404550
Flow Rate - USgpmFlow Rate - USgpm
25 psid cracking
Pre
ssur
e dr
op -
PS
ID
Pre
ssur
e dr
op -
PS
ID
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
Filter Element Flow Datamm (inch)
The OFR-30 with 8” element meets HF3 specifications.
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for viscosity corrections for pressure drop.)
Single layer 101 (4) length Single layer 203 (8) length
6021 C-Pak 203 (8) length
0 10 20 30 40 50 60 700
6
1012
18
20 40 60 80100 120 14000
5
10
15
201614
8
42
Pre
ssur
e dr
op -
PS
ID
Pre
ssur
e dr
op -
PS
ID 3M
7M7G
3M
7M
0
510
15
20
Flow Rate - USgpm
25
3003
0510
20
5 15 25 35 45 55 65 750
Pre
ssur
e dr
op -
PS
ID
Flow Rate - USgpm
01
Housing Bypass Valve
10M10M
31
Model Codes
Filter and Element
3 4 5 8761 2
Seals
Blank - Buna-NF3 - Viton
Viton is a registered trademark of E.I. DuPont
Filter type
OFR - Oil filter return line
Flow capacity
Port options
Element optionsC-Pak construction*(For use with OFR-30 only)
Code Fluid Cleanliness Elementrating construction
C01 Flushing only C-PakC03 16/14/12 C-PakC05 18/16/14 C-PakC10 20/18/15 C-PakC20 22/19/16 C-PakSingle layer construction**Code Micron3M Beta 15 = 1007M Beta 25 = 100Blank Beta 50 = 100
*NOTE: The C-Pak table assumes limitedingression and a single pass of pump flowthrough the element. For more detailedassistance, please consult Vickers Guide toSystemic Contamination Control, or contactyour local Vickers representative.
∆P indicator options
Blank - Mechanical 25 psidE - Electrical 25 psid
Design
Special suffix
**NOTE: Single layer construction elementsare not assigned cleanliness codes andtherefore cannot be applied toward VickersSystemic Contamination Control ExtendedWarranty program.
1
2
3
4
5
6
7
8
Filter element
V602
Element collapse rating1 - 150 psid
V-Pak or C-Pak element only
Seals
B - Buna-NV - Viton-A
Viton is a registered trademark of E.I. DuPont
Element lengthmm (inch)
Element construction
C - C-Pak (grade 01, 3, 5, 10, 20)
Fluid cleanliness ratings
Single layer media**replacement element kits
(Meets HF3 Specifications)3 4 5 61 2
1
2
3
4
5
6
15 - 57 L/min (15 USgpm)30 - 114 L/min (30 USgpm)
2 - 203 (8) (HF3 length) (OFR30)
(OFR-30 meets HF3 standard) OFR-15 737841 3M 15737840 7G 25737838 10M 50
F3-OFR-15 737845 3M 15737844 7G 25737843 7M 25737842 10M 50
OFR-30 737849 3M 15737848 7G 25737847 7M 25737846 10M 50
F3-OFR-30 737853 3M 15737852 7G 25737851 7M 25737850 10M 50
Element ElementModel Kit Code Micron
Element ElementModel Kit Code Micron
Code Fluid Elementcleanliness constructionrating
C01 Flushing only C-PakC03 16/14/12 C-PakC05 18/16/14 C-PakC10 20/18/15 C-PakC20 22/19/16 C-Pak
B - G1 (formerly 1” BSPF) threadF - 1” SAE 4-bolt flange Code 61S - 1.3125-12 UN SAE-16 straight thread 1” O.D. tube
**NOTE: Single layer construction elementsare not assigned cleanliness codes andtherefore cannot be applied toward VickersSystemic Contamination Control ExtendedWarranty program.
S50 -Head sub-assembly only (No element, bowl or indicator)
32
Dimensions
98,6(3.88)
218,9(8.62)OFR-15
87,4(3.44)
Dia.
133,4 (5.25)
131,8(5.19)
99,3(3.91)
Torque headbolts to
25–30 ft.lbs ( 33–41 Nm)
Connections1.312-12 UN SAE
1” G1 Britishpipe thread or
1” SAE 4-bolt flg.
66,5(2.62)
Outlet port
Inlet port
Memoryreset knob
Visual indicator
52,3(2.06)26,2(1.03)
Drain plug
26,2(1.03)
180,8(7.12)OFR15
273,1(10.75)OFR30
25,4 (1.00) Clearance for element removal
13,2(0.52)
311,2(12.25)OFR30
269,7(10.62)OFR-15
362,0(14.25)OFR30
267,5(10.53)
OFR-15
359,7(14.16)
OFR-30
177,8 (7.00)min. leadextension
53,8 (2.12)
1/2 NPTF thd.
NC
NO
C
Black
Red
Blue
GreenElectrical IndicatorSwitch Circuit
Mechanical Indicatormm (inch)
Electrical Indicatormm (inch)
3/8-16 UNC-2B0.64 min. full thread2-places
66,5(2.62)
33
OFR-60/120 Series Filters Flows to 454 L/min (120 USgpm)-Pressures to 27 bar (400 psi)
Features and Benefits� Two bowl length options.
� Visual indicator is standard.
� Electrical indicator also available.
� Bypass valve is standard.
� Replacement elements available inC-Pak or single layer construction.
� Accepts Eco-Pak coreless elements.
Design SpecificationsMeets HF4 specifications
Rated flow: OFR60 227 L/min (60 USgpm) OFR120 454 L/min (120 USgpm)
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.
Temp range: -40�C to +107�C(-40�F to +225�F)
Pressure rating: Operating 27 bar (400 psi)
Standard bypass valve setting:25 � 4 psid
Material: Head Die cast aluminum Bowl Carbon steel
Dry weight: (Approximate) OFR60 6,8 kg (15 lbs.) OFR120 9,5 kg (21 lbs.)
General DataThese filters are designed for use in thereturn lines of hydraulic systems. Theyremove particulate contaminants fromthe system fluid, thus improvingperformance and reliability of the systemcomponents while extending theirservice life. A bypass valve andmechanical visual indicator arestandard.
Bypass ValveAn internal relief valve parallels theelement to limit the pressure drop acrossthe element. The valve is set to open at25 PSID as standard.
Filter ElementsThese return line filters are offered inC-Pak media and in single layer media.
The C-Pak media has been designedto meet the requirements of VickersSystemic Contamination Controlprogram and are available in 3, 5, 10and 20 micron (99% efficient) ratings.To learn more on this program, consultVickers brochure. Replacementelements for C-Pak are ordered bymodel code.
In some systems, the single layermedia may offer an alternative. Theseare available in 15, 25 and 50 micron(99% efficient) ratings.
Refer to the model code page forfurther information on filter elementsand cleanliness ratings.
IndicatorsMechanicalA rotary type indicator is mechanicallyassociated with the bypass valve andindicates the condition of this valve.Visible through the transparentwindows in the protecting hood, theindicator will show green for a closedbypass valve and progressively showyellow for a warning that the elementpressure drop is getting into the dangerzone and red for an open bypassvalve. By removing the protecting hoodand reassembling the rotary indicator180� on its stem, the indicator nowprovides a “memory” in that it rotates tothe maximum opening of the bypassand remains in this position untilmanually returned by rotation of theknurled projecting knob.
ElectricalA lever actuated electrical switch ismounted in the enclosure. An actuatormounted to the bypass valvedepresses the switch just prior to theopening of the bypass valve to changethe completion of the electrical switchcircuit from the common and thenormally closed terminals to thecommon and normally open terminals.
Cover can be rotated at 90�increments to four different positions.
The 1/2 inch pipe tap is provided for connection to external conduit andlengths of color coded wires aresoldered to the switch terminals forconnection to the external circuit throughthe wires in the conduit. The switchcontacts are rated for 5 amperesresistive loading up to 250 Vac.
Mounting PositionAny mounting position is permitted.Vertical is preferred from a servicingstandpoint.
PortsStraight thread ports accept the SAEfittings. Flange ports accept the 4-boltSAE flange.
Straight thread connections providesuperior external leakage protection inapplications having pulsating pressuresor system vibrations.
Fluids and SealsHydraulic oils, water glycols andwater-in-oil emulsions can be filteredwith the standard unit.
Soluble oil in water fluids can also befiltered with the standard unit if the fluidpH does not exceed 8.5. A higher pHthan this has an adverse effect on thealuminum components.
Synthetic fluids require special sealswhich can be obtained by prefixing themodel number with “F3”.
Refer to Vickers ‘‘Hydraulic Hints &Troubleshooting Guide’’ #694 forhydraulic fluid and temperaturerecommendations.
34
Performance Curves
Filter Element Flow Datamm (inch)Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
0 20 40 60 80 100 120 1400
2
4
6
8
10
12
14
OFR-60
Flow Rate – USgpm
Pre
ssur
e dr
op -
PS
ID
OFR-120
510
1520
25
3035404550
20 40 60 80 100 12000
Flow Rate – USgpm
0
246
0 5 10 15 20 25 30 35 40 45 50
81012
03
05
10
20
14
6055
03
05
10
20
0
2468
101214
0 10 20 30 40 50 60 70 80 90 100 110 120
Flow Rate – USgpm Flow Rate – USgpm
4051 C-Pak 229 (9) length 4051 C-Pak 457 (18) length
Single layer 229 (9) length Single layer 457 (18) length
40200 10 20 30 40 50 60 700
5
10
15
20
0
2
4
6
8
10
12
14
16
60 80 100 120 1400
3M
7M
7G
3M
7M
7G
Flow Rate – USgpm Flow Rate – USgpm
Housing Bypass Valve
01 01
Pre
ssur
e dr
op -
PS
IDP
ress
ure
drop
- P
SID
Pre
ssur
e dr
op -
PS
IDP
ress
ure
drop
- P
SID
Pre
ssur
e dr
op -
PS
ID
10M
10M
35
Model Codes
Filter and Element
3 4 5 61 2
Seals
Blank - Buna-NF3 - Viton
Viton is a registered trademark of E.I. DuPont
Filter type
OFR - Oil filter return line
Flow capacity
60 - 60 USgpm (227 L/min)120 - 120 USgpm (454 L/min)
Port options
F - 1 1/2” SAE 4-bolt flange Code 61S - 1.875-12 UN SAE-24 straight thread for 1 1/2” O.D. tube
Element options C-Pak construction*
Code Fluid Cleanliness Elementrating construction
C01 Flushing only C-PakC03 16/14/12 C-PakC05 18/16/14 C-PakC10 20/18/15 C-PakC20 22/19/16 C-Pak
Single layer construction**Code Micron3M Beta 15 = 1007M Beta 25 = 1007G Beta 25 100Blank Beta 50 100
*NOTE: The C-Pak table assumes limitedingression and a single pass of pump flowthrough the element. For more detailedassistance, please consult Vickers Guide toSystemic Contamination Control, or contactyour local Vickers representative.
∆P indicator options
Blank - Mechanical E - Electrical
Design
Special suffix
S50 - Filter housing minus element(Omit element options designation.) ** NOTE: Single layer construction elements
are not assigned cleanliness codes andtherefore cannot be applied toward VickersSystemic Contamination Control ExtendedWarranty program.
(Omit if not required.)
1
2
3
4
5
6
7
8
Filter element
V405
Element collapse rating1 - 150 psid
C-Pak element only
Seals
B - Buna-NV - Viton-A
Viton is a registered trademark of E.I. DuPont
Element lengthmm (inch)
3 - 229 (9) (Use in OFR-60)6 - 457 (18) (Use in OFR-120)
Element construction
C - C-Pak (grade 01, 3, 5, 10, 20)
Fluid cleanliness ratings*
Single layer media**replacement element kits
OFR-60 737825 3M 15737823 7M 25737822 10M 50
F3-OFR-60 737829 3M 15737828 7G 25737827 7M 25737826 10M 50
OFR-120 737833 3M 15737831 7M 25737830 10M 50
F3-OFR-120 737837 3M 15737836 7G 25737835 7M 25737834 10M 50
Element ElementModel Kit Code Micron
(Meets HF4 Specifications)
(Meets HF4 Specifications)
*NOTE: Two 9 inch elements and aP-227567-01 reusable connector can also beused in the OFR-120 housing. Thisarrangement meets HF4 specifications.
Element ElementModel Kit Code Micron
3 4 5 61 2
1
2
3
4
5
6
Code Fluid Cleanliness Elementrating construction
C01 Flushing only C-PakC03 16/14/12 C-PakC05 18/16/14 C-PakC10 20/18/15 C-PakC20 22/19/16 C-Pak
** NOTE: Single layer construction elementsare not assigned cleanliness codes andtherefore cannot be applied toward VickersSystemic Contamination Control ExtendedWarranty program.
97 8
Bypass setting
Blank - 25 PSID Standard35 - 35 PSID50 - 50 PSID***
9
***CAUTIONApplications involving highflow surges may causeelement collapse due to
instantaneous pressure spikes.
36
Dimensions
90,9(3.58)
119,1(4.69)
Torque head bolts to 50 ft.lbs (67,79 Nm) dry
35 ft.lbs. (47,45 Nm)lubricated
A port Conn.2 places
25,4 (1.00) Clearance for element removal
Dia.117,9(4.64)
84,1(3.31)
168,1 (6.62)
162,1(6.38)
81,0(3.19)
66,5(2.62)
Outletport
Inletport
Memory resetknob
Visualindicator
88,9(3.50)
44,5(1.75)
Drain plug
93,0(3.66)
19,1 (0.75)
320,5(12.62)OFR60
550,9(21.69)OFR120
177,8 (7.00) min.lead extension
53,8 (2.12)
1/2 NPTF thd.
NC
NO
C
Black
Red
Blue
GreenElectrical IndicatorSwitch Circuit
Mechanical Indicatormm (inch)
Electrical Indicatormm (inch)
.500-13UNC-2B thd.
.75 deep2 holes for mounting
NotePlastic plug, part number 737365, isinstalled in the filter element to close theend of the element. When servicingelement, remove and retain plastic plug737365. Install new element with plasticplug on bottom.
37
Manifolds
327,2(12.88)
Design Specifications
Maximum flow capacity:946 L/min (250 USgpm)
Pressure rating: Operating 27 bar (400 psi)
Temp range: -40�C to +107�C(-40�F to +225�F)
Weight assembly: OFRM-12-20-10 2,7 kg (6.0 lbs.)
General DataThis SAE flange manifold assembly isdesigned for use with OFR-60 andOFR-120 large return line filters
The manifold assembly includes thefollowing:
(2) Cast aluminum manifolds(4) Seals(8) Bolts
Pressure DropPressure drop (�P) across manifolds isapproximately 2 psi when passing 240gpm flow (Q) of 100 SUS fluid(s) having.865 flow rate.
For any other flow rate (Q1), thepressure drop (�P1) will beapproximately:
�P1 = �P (Q1 /Q)2
For any other specific gravity (G1), thepressure drop (�P1) will beapproximately:
�P1 = �P (G1 /G)
For any other viscosity(s), the pressuredrop (�P) will change as follows:
Other % of (�P) viscosity(s) (Approx.)
75 93
150 111
200 119
250 126
300 132
350 137
400 141
4
3
2
1
4321
Model Code
TypeOFRM - Oil filter, return line manifold
Filter Connection Size
12 - 11/2” SAE flange Code 61
Line Connection Size
20 - 2 1/2” SAE flange Code 61
Design
Subject to change. Installationdimensions remain the same fordesigns 10 through 19.
82,6(3.25)
82,6(3.25)
50,8 (2.00)25,4 (1.00)
88,9 (3.50)44,5 (1.75)
96,0(3.78)
60,5(2.38)
35,6(1.40)
Typ.
17,8(.70) Typ.
35,1(1.38)
Typ.
69,9(2.75)
Typ.
.500-13 UNC-2B thd.4 holes each side
1 1/2 SAE4-bolt flangeconnection
41,1 (1.62)
25,4(1.00)
50,8(2.00)
.500-13 UNC-2B thd.1.00 deep 4 holes formounting
Dimensionsmm (inch)
25,4(1.00)
50,8(2.00)
2 1/2 SAE4-bolt flangeconnection
41,1 (1.62)
38
OFRS-15 Series Filters Flows to 57 L/min (15 USgpm) – Pressures to 7 bar (100 psi)
Features and Benefits� Simple spin-on element design for
easy maintenance.
� Bypass valves prevent excessivepressure drop and accidentalelement collapse.
� Two available ports for use as gaugeand/or diagnostic ports.
Design Specifications
Rated flow: 57 L/min (15 USgpm)
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.
Temp range: -40�C to +107�C(-40�F to +225�F)
Pressure rating: Operating 7 bar (100 psi)
Material: Head Die cast aluminum Bowl Carbon steel
Dry weight: (Approximate)1,0 kg (2.2 lbs.)
General DataThese filters are designed for use in thereturn lines of hydraulic systems. Theyremove particulate contaminants fromthe fluid, thus improving performanceand reliability of the system componentswhile extending their service life. R-Pakand single layer filter elements areavailable. The elements are of thedisposable spin-on cartridge type forease of maintenance.
Integral Bypass ValveThis bypass valve prevents excessivepressure drop and prevents theelement from collapsing and releasingretained contaminants back into thehydraulic system. The valve starts toopen when pressure drop across theelement exceeds the valve setting dueto flow surges, high viscosity oil, aclogged element, or a combination ofthese factors.
Filter ElementsThese return line filters are offered withtwo types of elements.
When system requirements call for flowto 15 USgpm and pressure drops to 30psid, the 5 layer high pressure R-Pakconstruction meets these demands.Replacement elements for R-Pak areordered by model code.
In applications where less demandsare placed on the system, the singlelayer element may offer a morepractical alternative. Replacement kitsare available for servicing the singlelayer element.
Refer to the model code page forfurther information on filter elementsand cleanliness ratings.
Gauge Ports and PressureGaugeAn optional port in the filter head allowsinstallation of a pressure gauge(P/N 736129) to indicate the element’scondition. This optional gauge isshipped uninstalled from the filter.
Spin-On CartridgeThe disposable cartridge screws ontothe filter head and should be handtightened per instructions printed on thecartridge.
Refer to the model code page for furtherinformation on filter cartridges andcleanliness ratings.
Mounting PositionAny mounting position is permitted.Vertical is preferred from a servicingstandpoint.
Fluids and SealsThese filters are suitable for petroleumbased, oil-water emulsions, high waterbase, and most water glycol fluids.
39
Performance Curves
40
Filter Assembly and Element Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections and page 7 for viscosity corrections for pressure drop.)
Filter assembly with40 micron element
105
20
15 20 25 30 35 40 45 50
0 20 40 60 80 100 120 140 160 180
3,0
2,0
1,0
Single Layer with 10 psid Bypass Valve
94%
78%61%
Filter assembly with25 micron element
105 15
510152025303540
0 10 20 30 40 50 60 70
3,0
2,0
1,0
20
Single Layer with 25 psid Bypass Valve
2,5
1,5
0,5
Filter assembly with25 micron element
25 psid bypassvalve only(Blocked element)
50%
V0191 R-Pak Filter Element 147 (5.8) length
105 15
2
4
6
8
10
0 10 20 30 40 50 60 70
0,6
0,4
0,1
20
0,5
0,2
0
V0191 R-Pak Filter Element 203 (8) length
R03
R05
R10 2
4
6
8
10
0 20 40 60
0,6
0,4
0,1
20
0,5
0,2
0
R03
R05
10 30
80 100 120 140
Pre
ssur
e dr
op -
bar
Flow Rate - USgpm
Flow Rate - L/min
Flow Rate - USgpm Flow Rate - USgpm
Flow Rate - USgpm
Flow Rate - L/min
Flow Rate - L/minFlow Rate - L/min
Pre
ssur
e dr
op -
PS
ID
Pre
ssur
e dr
op -
bar
Pre
ssur
e dr
op -
bar
Pre
ssur
e dr
op -
bar
Pre
ssur
e dr
op -
PS
ID
Pre
ssur
e dr
op -
PS
IDP
ress
ure
drop
- P
SID
71%
10 psid bypassvalve only(Blocked element)
59%10
40
30
Filter assembly with40 micron element
R10
NOTE: The % shown is the % of flow whichpasses thru a clean element with 150 SUSfluid. The remaining flow will pass thru thebypass valve without filtration.
40
Model Codes
Filter andElement
R-Pak Element
Outlet gauge port location(1/8” NPTF)
E - Location EBlank - Omit if not required.
Bypass valve
10 - Bypass valve set at 10 psidBlank - Bypass valve set at 25 psid
Design number
Subject to change. Dimensions remainthe same for designs 10 through 19.
Special suffix(Omit if not required.)
S50 - Filter housing minus element(Omit element options designation.)
Series designation
OFRS - Oil Filter, Return line, Spin-on
Flow rating
15 - 15 USgpm (57 L/min)
Port type
B - G1 (formerly 1” BSPF) thd.P - 1” NPTFS - 1.312-12 UN SAE-16 straight
thd. for 1” OD tube
1
2
3
4 5
6
7
8
9
Element type
Code Canister Fluid CleanlinessLength Codemm (inch)
1R03 147 (5.8) 16/14/121R05 147 (5.8) 18/16/141R10 147 (5.8) 20/18/152R03 203 (8.0) 16/14/122R05 203 (8.0) 18/16/142R10 203 (8.0) 20/18/15The table assumes limited ingression/single pass of pump flow throughelement. For detailed assistance, seeVickers Guide to SystemicContamination Control or contact yourlocal Vickers representative.
Code Filtration ElementRating Construction
25M 40 micron Single layerBlank 25 micron Single layerNOTE: Because single layer elements arenot assigned Fluid Cleanliness Codes, theyare not eligible for Vickers SystemicContamination Control Extended Warrantyprogram.
Pressure gauge option
P - Pressure gauge 0-120 psi (0-8 bar)Blank - Omit if not required.
Single Layer Media Element
Replace- Micron Rating Nominalment Ratingelement
573082 25 B25 = 100 10 micron
573083 40 B40 = 100 25 micron
NOTE: Because single layer elements arenot assigned Fluid Cleanliness Codes, theyare not eligible for Vickers SystemicContamination Control Extended Warrantyprogram.
3 4 5 61 2
Series designation
V019 - Filter element for use withOFRS15/OFRS25 – series filters(R–Pak construction only)
Element collapse rating
1 - 150 psid
Seal material
B - Buna–N
Element lengthmm (inch)
1 - 147 (5.8)2 - 203 (8.0)
Element construction
R - R–Pak
1
2
3
4
5
Element type
Code Fluid ElementCleanliness ConstructionCode
03 16/14/12 R–Pak05 18/16/14 R–Pak10 20/18/15 R–PakThe table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
6
Single Layer Media Element
Replacement element Micron Rating Nominal Rating
573082 25 B25 = 100 10 micron
573083 40 B40 = 100 25 micron
10
3 4 5 876 91 2 10
Inlet gauge port location(1/8” NPTF)
B - Location BBlank - Omit if not required.
41
Dimensions
44,4(1.75)
11,2(0.44)
12,7(0.50)
Clearance required forremoval of cartridge
Approx.55,9
(2.20)
98,8(3.89)
Inletport
Outletport
B Pressuregauge
connection E Pressure gauge connection1/8” NPTF pipe thd.2 locations (see Model Code)
23,9(0.94)
.375-16 UNC-2B thd.19,1 (0.75) min. full thd.2 holes for mountingMounting screw torque20-27 Nm (15-20 ft-lb)
Filter Housingmm (inch)
11,2(0.44)
13,5(0.53)
3,05R(0.12R)
9,53/9,78R(0.375/0.385R)
Typ.
Typ.
26,9(1.06)
26,9(1.06)
7,87R(0.31R)
24,4(0.96)
Hex. – bothends
Optionalpressure
gauge
47,8(1.88)
Std.170,2(6.70)Long226,1(8.9)
Std.194,6(7.66)Long250,4(9.86)
27,2 (1.07)
49,3(1.94)
97,5(3.84)
∅ Max.
42
OFRS-25 Series Filters Flows to 95 L/min (25 USgpm) – Pressures to 7 bar (100 psi)
Features and Benefits� Simple spin-on element design for
easy maintenance.
� Bypass valve prevents excessivepressure drop and accidentalelement collapse.
� Six available ports for use as gaugeand/or diagnostic ports.
Design SpecificationsRated flow: 95 L/min (25 USgpm)
Fluid Suitable for use withcompatibility: petroleum based,
oil-water emulsions,high water based andmost water-glycol fluids.
Temp range: -40�C to +107�C(-40�F to +225�F)
Pressure rating: Operating 7 bar (100 psi)
Material: Head Die cast aluminum Canister Carbon steel
Dry weight: (Approximate)0,9 kg (2.0 lbs.)
General DataThese filters are designed for use in thereturn lines of hydraulic systems. Theyremove particulate contaminants fromthe fluid, thus improving performanceand reliability of the system componentswhile extending their service life. R-Pakand single layer filter elements areavailable. The elements are of thedisposable spin-on cartridge type forease of maintenance.
Integral Bypass ValveThis bypass valve prevents excessivepressure drop and prevents theelement from collapsing and releasingretained contaminants back into thehydraulic system. The valve starts toopen when pressure drop across theelement exceeds the valve setting dueto flow surges, high viscosity oil, aclogged element, or a combination ofthese factors.
Filter ElementsThese return line filters are offered withtwo types of elements.
When system requirements call for flowto 25 USgpm and pressure drops to 30psid, the 5 layer high pressure R-Pakconstruction meets these demands.Replacement elements for R-Pak areordered by model code.
In applications where less demandsare placed on the system, the singlelayer element may offer a morepractical alternative. Replacement kitsare available for servicing the singlelayer element.
Refer to the model code page forfurther information on filter elementsand cleanliness ratings.
Gauge Ports and PressureGaugeAn optional port in the filter head allowsinstallation of a pressure gauge(P/N 736129) to indicate the element’scondition. This optional gauge isshipped uninstalled from the filter.
Spin-On CartridgeThe disposable cartridge screws ontothe filter head and should be handtightened per instructions printed on thecartridge.
Refer to the model code page for furtherinformation on filter cartridges andcleanliness ratings.
Mounting PositionAny mounting position is permitted.Vertical is preferred from a servicingstandpoint.
Fluids and SealsThese filters are suitable for petroleumbased, oil-water emulsions, high waterbase, and most water glycol fluids.
43
Performance Curves
Filter Assembly and Element Flow Datamm (inch)Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections and page 7 for viscosity corrections for pressure drop.)
Single Layer with 25 psid Bypass Valve
5 10 15 20 25 30
30
20
10
50
40
0,5
1,0
1,5
2,0
2,5
3,0
3,5
0 20 40 60 80 100
25 psid bypassvalve only(blocked element)
Filter assemblywith 40 micronelement
Filter assemblywith 25 micronelement
V0191 R-Pak Filter Element 147 (5.8) length
105 15
2
4
6
8
10
0 10 20 30 40 50 60 70
0,6
0,4
0,1
20
0,5
0,2
0
V0191 R-Pak Filter Element 203 (8.0) length
R03R05
R10 2
4
6
8
10
0 20 40 60
0,6
0,4
0,1
20
0,5
0,2
0
R03
R05
R10
10 30 40
80 100 120 140
Pre
ssur
e dr
op -
PS
ID
Pre
ssur
e dr
op -
bar
Flow Rate - USgpm
Flow Rate - L/min
Flow Rate - L/minFlow Rate - L/min
Flow Rate - USgpm Flow Rate - USgpm
Pre
ssur
e dr
op -
PS
ID
Pre
ssur
e dr
op -
PS
ID
Pre
ssur
e dr
op -
bar
Pre
ssur
e dr
op -
bar
44
Model Codes
R-Pak element
Inlet gauge port location (1/8” NPTF)A - Location AB - Location BC - Location CBlank - Omit if not required.
Outlet gauge port location (1/8” NPTF)
D - Location DE - Location EF - Location FBlank – Omit if not required.NOTE: Gauges cannot be mounted side byside. If inlet and outlet gauges are required,specify non-adjacent ports such as A and E.
Bypass valve0 - Non-bypassBlank - Bypass valve set at 25 psid
Design numberSubject to change. Dimensions remainthe same for designs 10 through 19.
Special suffix(Omit if not required.)
S50 - Filter housing minus element(Omit element options designation.)
Model Series
OFRS - Oil Filter, Return line, Spin-on
Flow rating
25 - 25 USgpm (95 L/min)
Port type
B - G1 (formerly 1” BSPF) thd.F - 1” SAE 4-bolt flange Code 61P - 1” NPTFS - 1.312-12 UN SAE-16 straight
thd. for 1” OD tube
3 4 5 876 91 2
1
2
3
4 5
6
7
8
9
Pressure gauge option
P - Pressure gauge 0-120 psi (0-8 bar)Blank - Omit if not required.
Element typeCanister Fluid Cleanliness
Code Length Codemm (inch)
1R03 147 (5.8) 16/14/121R05 147 (5.8) 18/16/141R10 147 (5.8) 20/18/152R03 203 (8.0) 16/14/122R05 203 (8.0) 18/16/142R10 203 (8.0) 20/18/15The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orconsult your local Vickersrepresentative.
Code Filtration ElementRating Construction
25M 40 micron Single layerBlank 25 micron Single layerNOTE: Because single layer elements are notassigned Fluid Cleanliness Codes, they arenot eligible for Vickers SystemicContamination Control Extended Warrantyprogram.
Single Layer Media Element
3 4 5 61 2
Series designationV019 - Filter element for use withOFRS15/OFRS25 series filters(R–Pak construction only)
Element collapse rating1 - 150 psid
1
2
3 Seal material
B - Buna–N
Element lengthmm (inch)
1 - 147 ( 5.8)2 - 203 (8.0)
Element construction
R - R–Pak
4
5
Element type
Code Fluid ElementCleanliness ConstructionCode
03 16/14/12 R–Pak05 18/16/14 R–Pak10 20/18/15 R–PakThe table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orconsult your local Vickersrepresentative.
6
Replacement element Micron Rating Nominal Rating
573082 25 B25 = 100 10 micron
573083 40 B40 = 100 25 micron
10
10
45
Dimensions
Std.194,1(7.64)Long250,4(9.86)
23,9(0.94)
81,0(3.19)
12,7(0.50)
Clearance required forremoval of cartridge
Inletport
Outletport
Optionalpressure
gauge
103,1(4.06)
51,6(2.03)
26,9(1.06)
53,8(2.12)
47,6 (1.88)
23,9(0.94)
40,4(1.59)
Approx.66,7
(2.62)
.375-16 UNC-2B thd.15,7 (0.62) min. full thd.4 holes for mountingMounting screw torque 20-27 Nm (15-20 ft-lb)
A
B
C
F Pressure gauge connection1/8” NPTF pipe thd.6 locations (see Model Code)
E
D
52,3(2.06)
26,2(1.03)
56,4(2.22)
∅
26,2(1.03)
13,1(0,52)
97,5(3.84)
.375-16 UNC-2B thd.16,3 (0.64) min. full thd.
4 holes each end only whenF port type is specified.
Use Vickers FL1-8-08P-10 orFL1-8-08W-10 flanges.
Filter Housingmm (inch)
Std.170,2(6.70)Long226,1(8.9)
46
OFRS-60 Series Filters Flows to 227 L/min (60 USgpm) – Pressures to 7 bar (100 psi)
Features and Benefits� Available with Vickers proprietary
R-Pak media.
� Simple spin-on element design foreasy maintenance.
� Optional bypass valves preventexcessive pressure drop andaccidental element collapse.
� Six available ports for use as gaugeand/or diagnostic ports.
� H20-Pro Water Removing Elementavailable.
Design SpecificationsRated flow: 227 L/min (60 USgpm)
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.
Temp range: -40�C to +107�C(-40�F to +225�F)
Pressure rating: Operating 7 bar (100 psi)
Material: Head Die cast aluminum Bowl Carbon steel
Dry weight: (Approximate) Bowl length 1 4,4 Kg (5.0 lbs) Bowl length 2 5,6 Kg (6.5 lbs)
General DataThese filters are designed for use in thereturn lines of hydraulic systems. Theyremove particulate contaminants fromthe fluid, thus improving performanceand reliability of the system componentswhile extending their service life. R-Pakand single layer filter elements areavailable. The elements are of thedisposable spin-on cartridge type forease of maintenance.
Integral Bypass ValveThis option prevents excessivepressure drop and prevents the elementfrom collapsing and releasing retainedcontaminants back into the hydraulicsystem. The valve starts to open whenpressure drop across the elementexceeds 25 psi due to flow surges, highviscosity oil, a clogged element, or acombination of these factors.
placed on the system the single layerelement may offer a more practical alter-native. Replacement kits are availablefor servicing the single layer element.Refer to the model code page for furtherinformation on filter elements andcleanliness ratings.
Spin-On CartridgeThe disposable cartridge screws ontothe filter head and should be tightenedper instructions on the cartridge.
Mounting PositionAny mounting position is permitted.Vertical is preferred for servicing.
Fluids and SealsThese filters are suitable for petroleumbased, oil-water emulsions, high waterbase, and most water glycol fluids.
R-Pak Elements
R03
R05R10R20
0211 R-Pak element 184 (7) length
R03
R05R10R20
0211 R-Pak element 286 (11) length
15
0
20
10
5
Flow Rate – USgpm100 5 15 20 3525 30 40
15
0
20
10
5
Flow Rate – USgpm550 5 15 653525 7545
6
0
8
4
2
Pre
ssur
e dr
op -
PS
ID
Flow Rate – USgpm200 10 30 40 50 60
Flow Rate – USgpm
50
40
30
20
10
Single Layer Elements
Gauge Ports/PressureGaugeOptional ports in the filter head allowinstallation of a pressure gauge (part736129) to indicate the element’scondition. The optional gauge isshipped uninstalled from the filter.
Filter ElementsThese return line filters are offered withtwo types of elements.
When system requirements call for flowto 60 USgpm and pressure drops to 30psid the high pressure R-Pakconstruction meets these demands.Replacement elements for R-Pak areordered by model code.
In applications where less demands are
Filter Housing Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9 (See page 6 for specific gravity corrections for pressure drop.)
Filter Element mm (inch)Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
Flow Rate – USgpm
50
40
30
20
10
10 20 30 40 50
H20-Pro Water RemovingElement W0211B2W10 286 (11) length
Pre
ssur
e dr
op -
PS
IDP
ress
ure
drop
- P
SID
Pre
ssur
e dr
op -
PS
ID
Pre
ssur
e dr
op -
PS
ID
Filter assembly with15 micron element
Filter assembly with25 micron element
Bypass valve only(blocked element)
Filter assembly with 60 micron element10 20 30 40 50 60
47
Dimensions
OFRS-60Body or LIne Mountingmm (inch)
35,6(1.41)
17,9(0.70)
69,9(2.75)
34,8(1.37)
HG
128,5(5.06)
∅
136,5(5.38)
∅
.5000-13 UNC-2B thd.0.875 min. full thd.
4 holes each end only whenF port type is specified.
Use Vickers FL1-12-12P-10 orFL1-12-12W-10 flanges.
33,3 (1.31)Clearance required forremoval of cartridge
56,4(2.22)
∅
Inletport
Outletport
Optionalpressuregauge
122,9(2.84)
26,9(1.06)
144,5(5.69)
Approx.85,7
(3.38)
A
B
C
53,8(2.12)41,3
(1.62)
F Pressure gauge connection1/8” NPTF pipe thd.6 locations (see Model Code)
.375-16 UNC-2B thd.0.75 min. full thd.2 holes for mountingMounting screw torque 15-20 lb. ft(20-27 Nm)
81,0(3.19)
40,4(1.59)
E
D
53,8(2.12)
31,7(1.25)
NOTE
A, B, C Inlet gauge port locations
D, E, F Outlet gauge port locations
DimensionElement G H
Standard 211,1 242,8(8.31) (9.56)
Long 312,7 344,4(12.31) (13.56)
48
Dimensions
OFRS-60-2Manifold MountingOutlet Port Connectionmm (inch)
35,7(1.41)
17,8(0.70)
128,5(5.06)
∅
136,5(5.38)
∅33,3 (1.31)Clearance required forremoval of cartridge
∅
Inletport
Outletport
Optionalpressuregauge
F Pressure gaugeconnection 1/8” NPTFpipe thd. 6 locations(see Model Code)
.375-16 UNC-2B thd.0.75 min. full thd.2 holes for mountingMounting screw torque 15-20 lb. ft(20-27 Nm)
31,7(1.25)
211,1 (8.31*)
* Add 101,6 (4.00) for long 10mm element.
Note
A, B, C Inlet gauge port locations
D, E, F Outlet gauge port locations
Pressure gauge in locations D and Fwill require additional fitting to clearmounting bolt hex nuts. Use AeroquipNo. 2040-2-25 or equivalent.
.5000-13 UNC-2B thd.0.875 min. full thd.
4 holes each end only whenF port type is specified.
Use Vickers FL1-12-12P-10 orFL1-12-12W-10 flanges.
69,8(2.75) 34,7
(1.37)
17,8(0.70)
38,1(1.50)
∅ 35,7(1.41)
Seal groove to accept A-225 seal5,38 (2.12)OD x 47,7 (1.88)
ID x 3,05 (0.12) C/S
∅ 10,3 (0.41)Thru holes for
mounting
60,2 (2.37)
120,7 (4.75)
56,4 (2.22)
122,9(2.84)
26,9(1.06)
144,5(5.69)
A
D
53,8(2.12)
81,0(3.19)
40,4(1.59)
Approx.85,7
(3.38)
139,7(5.50)
41,3(1.62)
53,8(2.12)
B
D
E
49
Model Codes
Inlet gauge port location(1/8” NPTF)
A - Location AB - Location BC - Location CBlank – Omit if not required
Outlet gauge port location(1/8” NPTF)
D - Location DE - Location EF - Location FBlank - Omit if not required
NOTE: Gauges cannot be mounted side byside. If inlet and outlet gauges are required,specify non-adjacent ports such as A and E.
Bypass valve
0 - No bypass valveBlank - Bypass valve set at 25 psid
Design number
Subject to change. Dimensions remainthe same for designs 10 through 19.
Special feature suffix
S14 - Long 25 micron elementS50 - Housing without element
(omit code for element type)Blank - Omit if not required
Element typeCanister Fluid Cleanliness
Code Length Codemm (inch)
1R03 - 184 (7) 16/14/121R05 - 184 (7) 18/16/141R10 - 184 (7) 20/18/151R20 - 184 (7) 22/19/162R03 - 286 (11) 16/14/122R05 - 286 (11) 18/16/142R10 - 286 (11) 20/18/152R20 - 286 (11) 22/19/162W10 - 286 (11) Water Removal
The table assumes limited ingression/single pass of pump flow throughelement. For detailed assistance, seeVickers Guide to SystemicContamination Control or contact yourlocal Vickers representative.
Other element options:Filtration Element
Code rating construction
3M - 15 micron Single layer25M - 60 micron Single layerBlank- 25 micron Single layer
NOTE: Because single layer elements arenot assigned Fluid Cleanliness Codes, theyare not eligible for Vickers SystemicContamination Control Extended Warrantyprogram.
Pressure gauge option
P - Pressure gaugeBlank - Omit if not required
Series designation
OFRS - Oil Filter, Return line, Spin-on
Flow rating
60 - 60 USgpm (227 L/min)
Mounting
2 - Reservoir mount flange (outlet)Blank - Body or line mounting
Port type
B - G11/2 (formerly 11/2” BSPF) thd.F - 11/2” SAE 4-bolt flangeP - 11/2” NPTFS - 1.875-12 UN SAE-24 straight thd.
for 11/2” OD tube
Filter and Element
3 4 5 876 9 101 2 11
1
2
3
4
5
6
7
8
9
10
11
50
Model Codes
Series designation
V021 - Filter element for use withH021, H022, H023 andOFRS-60 series filters(R-Pak construction only)
W021 - Water Removal element for use with H021, H022, H023and OFRS-60 series filters
Element collapse rating
1 - 150 psid
Seal material
B - Buna-N
Canister lengthmm (inch)
1 - 184 (7)2 - 286 (11)
NOTE: Water removal element only availablein length 2.
Element construction
R - R-Pak (grade 3,5,10,20)W - W-Pak (Water Removal) (grade 10)
Fluid cleanliness rating
FluidCleanliness Element
Code Code construction
03 - 16/14/12 R-Pak05 - 18/16/14 R-Pak10 - 20/18/15 R-Pak,
W-Pak20 - 22/19/16 R-Pak
The table assumes limited ingression/single pass of pump flow throughelement. For detailed assistance, seeVickers Guide to SystemicContamination Control or contact yourlocal Vickers representative.
R-Pak Element Only
3 4 5 61 2
1
2
3
4
5
6
Single Layer Media Element Only
ReplacementElement Number Micron Rating Nominal Rating
941190 Std. Length 15 B15 = 100 3 micron
941107 Std. Length 25 B25 = 100 10 micron
926388 Long Length 25 B25 = 100 10 micron
941191 Std. Length 60 B60 = 100 25 micron
NOTEBecause single layer elements are notassigned Fluid Cleanliness Codes, theyare not eligible for Vickers SystemicContamination Control ExtendedWarranty program.
51
H021/23 Series Filters Flows to 227 L/min (60 USgpm) - Pressures to 14 bar (200 psi)
Design Specifications
Rated flow: 113,5 L/min (30 USgpm)cannister length 1227 L/min (60 USgpm) cannister length 2
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.
Temp range: - 32�C to + 107�C(- 25�F to + 225�F)
Pressure rating: Operating 14 bar (200 psi)
Material: Head Cast iron
Dry weight: (Approximate) 7 inch 1,4 Kg (3 lbs.) 11 inch 2,2 Kg (5 lbs.)
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Large selection of visual, electricaland electrical visual �P indicatorsavailable for design flexibility.
� Spin-on cartridges make servicingfast and easy.
� Replacement elements available inR-Pak media.
� H20-Pro Water Removing elementavailable.
Features and Benefits
3 4 5 876 91 2
Housing Model Code
Filter series
H021 - Machined for pressure gauge onlyH023 - Machined for �P indicators
NOTE: Filter head H021 is furnished with twoports drilled, tapped and plugged for gauge orswitch option.
NOTE: H023 plugged ∆P port machined forindicators.
Port options
Valve bypass setting
3 - Bypass set at 25 ± 3 PSID4 - Bypass set at 50 ± 5 PSID
C - 1.625-12UN SAE-20 straight thread(11/4” tube)
P - 11/4” NPT
Element collapse rating
1 - 150 PSID
1
2
3
4
BypassH023H021
3 1, 4, 6, 8 C,F,J,K,Q,X4 1, 2, 7, 9 D,G,J,L,M,R,Y
Indicator Selection GuideHead Type
Indicator type
C - Electrical/visual ∆ P 15 ± 4 PSID��� ������������ ����������������F - Electrical/visual ∆ P 15 ± 4 PSID thermal lockout (100�F)��� ������������ ����������������
������������ ������������ ��∆P indicatorK - Visual ∆P indicator with 15 ± 4
PSID actuation & thermal lockout (100� F)
��� !�� ������"#������$����������������� ���"�%������������� ���������
M - Visual �P indicator w/ 35 ± 5 PSID,thermal lockout (100� F) and surgecontrol
Q - Electrical ∆P switch with 15 ± 4 PSID actuation
��� ���������������$�����$������������������ ���"
��� ������������ �����������&������������������ ����������%�� �'����"����
��� ������������ ������������������������������ ����������%�� �'����"����
5
First designator (Differential pressureindicator for H023)
Second designator (ReceptacleStyle)B - 5 pin Brad Harrison (41512) H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual
∆P indicators and gauge options 1, 2 & 4
Upstream pressure indicators for H0211 - No indicator – Pipe plug installed2 - 0 to 200 psi pressure gauge4 - 0 to 60 psi pressure gauge6 - Electrical switch, 18 psi -
Brad Harrison7 - Electrical switch, 35 psi -
Brad Harrison 8 - Electrical switch, 18 psi -
DIN 43650 9 - Electrical switch, 35 psi -
DIN 43650 (See page 7 for wiring diagram.)
Seal material
B - Buna-N
Canister lengthmm (inch)
Element constructionR - R-Pak (grade 3,5,10,20)W- W-Pak, Water Removal (grade 10)
Fluid cleanliness ratings
CodeTarget fluid cleanliness level
030510
20
16/14/1218/16/1420/18/15
22/19/16
6
7
8
9
1 - 184 (7)2 - 286 (11)
NOTE: Water removal element onlyavailable in length 2.
Elementconstruction
R-PakR-PakR-PakW-PakR-Pak
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
S50 -Head sub-assembly only (No element, bowl or indicator)
52
Dimensions
H021/H023 Housingmm (inch)
AccessoriesElectrical switch (18 psi)� Brad Harrison P-234117-01�Electrical switch (35 psi)� Brad Harrison P-234118-01�Electrical switch, (18 psi) DIN�
P-233051-01�Electrical switch, (35 psi) DIN�
P-233573-01�Gauge, (0-60 psi*) (Color coded)
P-232965-01�Gauge, (0-200 psi) P-232974-01�*For use with 25 psi bypass only� See page 97 for electrical switch installation.� See page 97 for gauge installation.
Gauge port 1/8NPTF plugged
2 places
38,1(1.50)
19,0(0.75)
148,0(5.83)
74,1(2.90)
�P Indicator(H023 head only)
68,3(2.69)
47,7(1.88)
39,4(1.59)
5/16–18 UNC5/8 deep fullthread (4 places)
OUT
IN
133,3 (5.25)
286(11.30)
184(7.30)
251,5(9.90)
126 (4.95)
05
1015
0Flow Rate – USgpm
Pre
ssur
e dr
op –
PS
ID
20 40 60
2025
3035
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
� Customer to furnish mating connector.
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
60
40
20
020 40 600
Bypass Valve
50 PSID Valve
25 PSID Valve
80
25
50
Housing
32
53
021 Series Replacement Filter Elements
Rated flow 113.5 L/min (30 USgpm)cannister length 1227 L/min (60 USgpm)cannister length 2
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.
Construction R-Pak, W-Pakmedia:
Temp range: - 32�C to +107�C(- 25�F to +225�F)
Design specifications
Element Model Code
Filter element
Element collapse rating
1 - 150 PSID
1
2
V0211 R-Pak 184 (7) length
Pre
ssur
e dr
op –
PS
ID
0
03
10 20 30Flow Rate - USgpm
15 25 35 405
V0211 R-Pak 286 (11) length
3 4 5 61 2
V021 - For use with H021, H022, H023 and OFRS-60 seriesfilters
W021 - Water Removal Element for use with H021, H022, H023 and OFR-S60 series filters
Seal material
B - Buna-N
3
Canister lengthmm (inch)
Element construction
4
5
1 - 184 (7)2 - 286 (11)
NOTE: Water removal element onlyavailable in length 2.
R - R-Pak (grade 3,5,10,20)W - W-Pak, Water Removal (grade 10)
Fluid cleanliness ratings6
Code Target fluid cleanlinesslevel
030510
20
16/14/1218/16/1420/18/15
22/19/16
Elementconstruction
R-PakR-PakR-PakW-PakR-Pak
Dimensions mm (inch)
184(7.3)
286(11.3)
126(5.0)
05
10
0
03
20 40 6030 50 70 8010
05
10
20
20
10
9876543210
109876543210
Pre
ssur
e dr
op –
PS
ID
50
40
30
20
10
10 20 30 40 50
H20-Pro Water Removing Element W0211B2W10 286 (11) length
R-Pak ElementsP
ress
ure
drop
– P
SID
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
11/2’’-16UN thd.
Flow Rate - USgpm
Filter Element Flow Datamm (inch)Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of ≤ 0.9(See page 7 for viscosity corrections for pressure drop.)
54
H022 Series Filters Flows to 454 L/min (120 USgpm) – Pressure to 14 bar (200 psi)
Rated flow 227 L/min (60 USgpm)cannister length 1454 L/min (120 USgpm)cannister length 2
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.
(��)��"'�* ���+�,����-��.�,
���+�������-++����
Pressure rating: Operating 14 bar (200 psi)
/�����*
��0�# 1� ��" �
��2�$��'��*�
��1))��3������ �4+�5'��.6���7�
Design Specifications
Features and Benefits Housing Model Code
Filter seriesH022
Element collapse rating
1 - 150 PSID
1
3 4 5 876 91 2
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Flexible mounting capability withoptional heavy duty bracket.
� Large selection of visual, electricaland electrical visual �P indicatorsavailable for design flexibility.
� Spin-on cartridges make servicingfast and easy.
� Replacement elements available inR-Pak media.
� H20-Pro Water Removing Elementavailable.
10
Port options
Valve bypass setting3 - Bypass set at 25 ± 3 PSID4 - Bypass set at 50 ± 5 PSID
D - 1.875-12Un SAE-24 straight thread (11/2” tube)
E - 11/2” SAE 4-bolt split flange Code 61U - 11/2” NPT
3
4
�P indicator & receptacle optionsFirst designator (Indicator type)C - Electrical/visual ∆ P 15 ± 4 PSIDD - Electrical/visual ∆ P 35 ± 5 PSIDF - Electrical/visual ∆ P 15 ± 4 PSID
thermal lockout (100� F)G - Electrical/visual ∆ P 35 ± 5 PSID
thermal lockout (100� F)J - No ∆P indicatorK - Visual ∆P indicator with 15 ± 4 PSID
actuation & thermal lockout (100� F)L - Visual ∆P indicator with 35 ± 5 PSID
actuation & thermal lockout (100� F)M - Visual �P indicator w/ 35 ± 5 PSID,
thermal lockout (100� F) and surgecontrol
Q - Electrical ∆ P switch with 15 ± 4 PSIDactuation
R - Electrical ∆ P switch with 35 ± 5 PSIDactuation
��� ������������ �����������&������������������ ����������%�� �'����"����
��� ������������ ������������������������������ ����������%�� �'����"����
Upstream pressure indicators for H0221 - No indicator – pipe plug installed2 - 0 to 200 psi pressure gauge4 - 0 to 60 psi pressure gauge6 - Electrical switch, 18 psi -
Brad Harrison7 - Electrical switch, 35 psi -
Brad Harrison8 - Electrical switch, 18 psi -
DIN 43650 9 - Electrical switch, 35 psi -
DIN 43650
5
Seal material
B - Buna-N
Canister lengthmm (inch)
Element constructionR - R-Pak media (grade 3,5,10, 20)W - W-Pak, Water Removal (grade 10)
Brackets
Fluid cleanliness ratings
CodeTarget fluid cleanliness level
030510
20
16/14/1218/16/1420/18/15
22/19/16
6
7
8
9
10
1 - 184 (7)2 - 286 (11)
NOTE: Water removal element onlyavailable in length 2.
Elementconstruction
R-PakR-PakR-PakW-PakR-Pak
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Bypass Pressure
3 1, 4, 6, 8 C,F,J,K,Q,X4 1, 2, 7, 9 D,G,J,L,M,R,Y
Indicator Selection Guide
Second designator (Receptaclestyle)
B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual ∆ P indicators and gauge options
1, 2 & 4(See page 7 for wiring diagram.)
�Pressure
1 - No bracket(Order #P-233052-01)
S50 -Head sub-assembly only (No element, bowl or indicator)
2
55
Dimensions
Filter Housing/Bypass Valve Flow Data
H022 Housingmm (inch)
69,8 (2.75)
34,9 (1.37)
91,4 (3.60)45,7 (1.80) 7/16-20 UNF 5/8 deep
(4 places)
IN
OUT
Refer to model codefor port options
1/8 NPTFPressure side only 2 places Gauge port plugged
184,4(7.26)
286,1(11.26)
147,8(5.82)
125,7(4.95)
Typ.
62,7(2.47)
31,7(1.25)
10,2(0.40)
17,1(0.67)
Note: An additional50,8 (2.00) is requiredfor cannister removal.
Flow Rate – USgpm
Housing
Pre
ssur
e dr
op –
PS
ID
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressuredrop.)
18
16
14
12
10
8
6
4
2
00 20 40 60 80 100 120
AccessoriesElectrical switch (18 psi)� Brad Harrison P-234117-01�Electrical switch (35 psi)� Brad Harrison P-234118-01�Electrical switch, (18 psi) DIN� P-233051-01�Electrical switch, (35 psi) DIN� P-233573-01�Gauge, (0-60 psi*) (Color coded)
P-232965-01�Gauge, (0-200 psi) P-232974-01�
*For use with 25 psi bypass onlyMounting bracket P-233052-01� See page 97 for electrical switch installation.� See page 97 for gauge installation. See page 98 for mounting bracket installation.
NOTE� Filter head is furnished with two ports drilled,
tapped and plugged for gauge or switch option.� Plugged �P port machined for indicators.
� Customer to furnish mating connector.
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
60
40
20
040 600
Bypass Valve
50 PSID Valve
25 PSID Valve
80
25
50
80 100 120
65
45
73,0(2.88) 146,0
(5.75)
56
021 Series Replacement Filter Elements
Rated flow 227 L/min (60 USgpm)cannister length 1454 L/min (120 USgpm)cannister length 2
�� �#� ,��)��7���$��������
���)��7����2* )������ �����4�$���
'�2���4������"�$����"#
$�����"�����8� �#�6
,�"��� ����" 9���4�:���
��#�*
(��)��"'�* ���+�,����-��.�,
���+�������-++����
Design specifications
Element Model Code
Filter element
Element collapse rating
1 - 150 PSID
1
2
����� ������������������
����� ���#��)�;�����
�
03
10 20 30Flow Rate - USgpm
15 25 35 405
����� �������������������
3 4 5 61 2
V021 - For use with H021, H022, H023 and OFR-S60 seriesfilters
W021 - Water Removal Element for use with H021, H022, H023 and OFR-S60 series filters
���������� ��
!���< "�
3
"�� #���������������"���
$�������%&�#��'%� &�
4
5
1 - 184 (7)2 - 286 (11)
NOTE: Water removal element onlyavailable in length 2.
R - R-Pak (grade 3,5,10, 20)W - W-Pak, Water Removal (grade 10)
(�' )�%����� ��##���� ��#6
Code Target fluid cleanlinesslevel
030510
20
16/14/1218/16/1420/18/15
22/19/16
Elementconstruction
R-PakR-PakR-PakW-PakR-Pak
Dimensions mm (inch)
184(7.30)
286(11.30)
126(5.00)
05
10
�
03
20 40 6030 50 70 8010
05
10
20
20
10
9876543210
109876543210
����� ���#��)�;�����
25
20
15
10
5
10 20 30 40 50
H20-Pro Water Removing Element W0211B2W10 286 (11) length
R-Pak Elements����� ���#��)�;�����
Filter Element Flow Datamm (inch)Flow versus pressure drop150 SUS (32 cSt) oil with specific gravity of ≤ 0.9(See page 7 for viscosity corrections for pressure drop.)
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpm
11/2”-16UN thd.
NOTEH022 assemblies use two elements inparallel. The flow thru each elementwill be 1/2 the total flow.
57
OF3 Series Inlet Strainers Flows to 379 L/min (100 USgpm)
Features and Benefits� Stainless steel elements have 149
micron (100 mesh) screen to protecthydraulic pumps from solidcontaminants.
� Available flow rates to 379 L/min(100 USgpm). Higher rates can beachieved by using multiple strainers.
� Bypass valve available to preventsystem shutdown.
� Element media is pleated for longlife.
� Elements can be cleaned andreused.
Design Specifications
Rated flow: OF3-08 38 L/min (10 USgpm) OF3-10 76 L/min (20 USgpm) OF3-12 114 L/min (30 USgpm) OF3-16 189 L/min (50 USgpm) OF3-20 284 L/min (75 USgpm) OF3-24 379 L/min (100 USgpm)
Fluid compatibility:These strainers are compatible withall commonly used hydraulic fluids,including phosphate esters and waterbased fluids.
Temp range: -40�C to +107�C(-40�F to +225�F)
Filtration: Unit is supplied with149 micron (100 mesh)wire cloth element.
Material: Head Nylon Element Pleated stainless steel
Dry weight: (Approximate) OF3-08 0,3 kg (0.7 lbs) OF3-10 0,4 kg (1.0 lbs) OF3-12 0,6 kg (1.4 lbs) OF3-16 0,8 kg (1.8 lbs) OF3-20 1,0 kg (2.3 lbs) OF3-24 1,4 kg (3.0 lbs)
General DataThese Vickers inlet strainers protecthydraulic pumps and control systemsfrom solid contaminants. They shouldbe used as immersion suction strainerson pump inlet lines.
Bypass ValveAn available integral relief valveparallels the element and is preset toopen at a 3 psi pressure drop acrossthe element. Element bypassing can becaused by excess flow rates, high fluidviscosity, dirt-loaded elements, or acombination of these.
Element SelectionThe size and number of elementsselected should be based on themaximum flow ratings listed on thispage. The ratings are conservative, anda change in fluid viscosity should notsignificantly affect capacity.
CleaningThe strainer elements should becleaned periodically. Remove theelements from the reservoir, washthoroughly in a suitable solvent, andblow dry with air from inside to outside.
3 41 2
Model Series
OF3 - Inlet strainers
Port Size (NPTF)
08 - 1”10 - 11/4”12 - 11/2”16 - 2”20 - 21/2”24 - 3”
1
2
Bypass Valve
3RV - 3 psi differential opening pressureBlank - Omit if not required
Design number
Subject to change. Dimensions remainthe same for designs 10 through 19.
3
4
Model Code
58
Installation Dimensions
C
∅ B
A
Inlet Strainermm (inch)
Model SeriesMinimum Screen Areacm2 (in2) A (NPTF pipe thread) B C �3,2 (�0.125)
OF3-08 710 (110) 1” 67,8 (2.67) 135,9 (5.35)
OF3-10 1032 (160) 11/4” 88,1 (3.47) 174,0 (6.85)
OF3-12 2194 (340) 11/2” 101,6 (4.00) 250,2 (9.85)
OF3-16 2194 (340) 2” 101,6 (4.00) 250,2 (9.85)
OF3-20 2581 (400) 21/2” 131,3 (5.17) 256,5 (10.10)
OF3-24 3226 (500) 3” 131,3 (5.17) 299,2 (11.78)
Typical Installations
Pump intakeconnection
Oil level Disconnect pipe unionto remove strainers
Pipe joints submergedAccess opening should be provided sostrainers can be removed for cleaningwithout draining fluid from tank.
59
10F, 50F and 100F Series - Indicating Inlet Strainers Flows to 700 L/min (185 USgpm) - Pressures to 0,3 bar (5 psi) vacuum to 20 bar (300 psi) positive
Features and Benefits� Stainless elements have 149 micron
(100 mesh) screen to protect pumpsfrom solid contaminants.
� Available flows to 700 L/min (185USgpm) on pressure inlets and 530L/min (140 USgpm) on vacuuminlets.
� Standard integral air bleed featureprevents formation of large bubbles.This provides faster priming ofpumps at startup and prevents pumpdamage.
� Housing can be adapted to handlemost hydraulic fluids.
� Large, easy to read, standard visualindicator (or optional electricalindicator) informs operator whenelement needs to be cleaned.
� Elements can be cleaned andreused.
� Standard bypass valve protectsagainst pump damage.
Design Specifications
Rated flow: See table
Temp range: -40�C to +107�C(-40�F to +225�F)
Pressure rating: 10F and 50F: 0,3 bar (5 psi)
vacuum to 3 bar (50 psi)positive
100F: 20 bar (300 psi)
Filtration: Filter is supplied with149 micron (100 mesh)wire cloth element.
Fluid and seals:Standard model is compatible withmost petroleum oil, water glycol, andwater-in-oil fluids. Optional seals sandcoatings are available for use inphosphate esters and oil-wateremulsions. See fluids and seals notein Model Code.
Material: Cover Die cast aluminum Housing Cast aluminum
Dry weight: (Approximate) 10F: 2,5 kg (5.5 lb.) 50F: 5,7 kg (12.5 lb.) 100F: 16,3 kg (36.0 lb.)
Maximum Flow RatingsThis table presents recommendationsfor use in both pressurized inletsystems and the more commonvacuum inlet systems. The effects offluid viscosity, specific gravity, and fluidflow rate on the pump inlet system(including the filter) have been takeninto consideration. Even with a bypasscondition in effect due to element dirtloading, a margin of pump protection isstill afforded.
Vacuum Inlet* Pressurized Inlet**
Normal Special Normal SpecialService Service Service Service
Model L/min L/min L/min L/minSeries (USgpm) (USgpm) (USgpm) (USgpm)
10FA 45 (12) 30 (8) 61 (16) 42 (11)
50FB 106 (28) 76 (20) 140 (37) 95 (25)
50FC 178 (47) 125 (33) 257 (68) 167 (44)
50FD 254 (67) 178 (47) 329 (87) 238 (63)
100FE 367 (97) 284 (75) 492 (130) 367 (97)
100FF 530 (140) 367 (97) 700 (185) 492 (130)
* 0,3 bar (5 psi) vacuum to 0 bar (0 psi)** 0 bar (0 psi) to 50 bar (3.5 psi) For use with petroleum oil up to 48 cSt (225 SUS) with less than
457 mm (18 in.) lift on vacuum applications. For use with petroleum oils above 48 cSt (225 SUS) and fire resistant fluids.
60
Indicating Inlet Strainers
General DataThese units have been designed for usein the intake lines of hydraulic pumps toafford a degree of protection fromcontaminants to the pump and othercomponents in the hydraulic system.
Bypass ValveAn integral relief valve parallels theelement and is preset to open at a 2 psi(standard) or 3 psi (optional) pressuredrop across the element. Elementbypassing can be caused by excessflow rates, high fluid viscosity,dirt-loaded elements, or a combinationof these.
Air BleedThese strainers include a standardintegral air bleed. It provides fasterpump priming on startup and limits theagglomeration of small air bubbles intolarger ones. Large air bubbles aredetrimental to pump operation.
The unit may be mounted in anyposition desired. To ensure properoperation of the air bleed feature,however, the inlet port must be pointeddown.
MagnetsMagnets are available as an accessoryand are installed in the filter on theoutside of the element. They act toattract and retain ferrous particles of allsizes, some of which could be smallenough to pass through the elementmesh and into the pump if no magnetswere present.
IndicatorsVisualA highly visible mechanical indicator islinked to the bypass valve. Theindicator shows green when the bypassvalve is closed and progressively moreyellow as a warning when the elementpressure drop gets into the dangerzone. Red indicates an open bypassvalve. The indicator will alsoautomatically show red, (bypasscondition) if the unit is accidentallyoperated without an element.
The visual indicator can also bereassembled to provide a “memory”function. If the protecting hood isremoved and the rotary indicator turned180� on its stem, the unit will indicatethe maximum opening of the bypassand remain in that position until resetby rotating the knurled projecting knob.
ElectricalA lever-actuated electric switch ismounted in the indicator enclosure. Theswitch is depressed by a cam mountedto the bypass valve just prior to theopening of the valve. This changes thecompletion of the electrical switchcircuit from the common and thenormally closed terminals to thecommon and normally open terminals.Switch actuation will also occur whenthe unit is accidentally operated withoutan element.
A 1/2” pipe tap is provided forconnecting a conduit, and lengths ofcolor coded wires are soldered to theswitch terminals for connecting to theexternal circuit through the conduitwires. The switch contacts are rated for 5 amps resistive loading up to250V AC.
GREEN
BLUE
RED
BLACK
CNC
NO
Switch Circuit
61
Model Code
Indicator
E - ElectricalL - Less (without) indicator partsBlank - Omit for mechanical.
Bypass Valve
3 - 3 psi differential opening pressureBlank - Omit for 2 psi differential opening
pressure.
Option
M - MagnetsBlank - Omit if not required.
Design number
Subject to change. Dimensions remainthe same for designs 12 and 20.12 - Mechanical indicator or no
indicator20 - Electrical indicator
Port Size
A - 1” (10F)B - 11/2” (50F)C - 2” (50F)D - 21/2” (50F)E - 3” (100F)F - 31/2” (100F)
Mean Filtration Rating
1 - 149 micron (100 mesh)
Port Type
B - G1 (formerly 1” BSPF) thd.(10F only)
F - 4-bolt SAE flangeP - NPTF pipe thd. in housing**S - SAE straight thd. in housing (except 50FD and 100 F)PF - Inlet: NPTF pipe thd. in housing
Outlet: 4-bolt SAE flangeSF - Inlet: SAE straight thd. in housing
Outlet: 4-bolt SAE flange
** Not recommended
CAUTION
Use pipe sealant to ensureairtight connections onpipe threaded models. Seetag on unit.
Fluid Compatibility*
F3 - Special sealsF6 - For oil-in-water emulsionsBlank – Omit if not required.
* Use of synthetic, fire-resistant fluidsrequires filter with special seals. Addprefix F3 to model number whenphosphate esters or their blends are tobe used. Oil-in-water emulsions requirecorrosion protection of aluminum parts.Add prefix F6 when using such fluids.Water glycol, water-in-oil emulsions, andpetroleum oil fluids may be used withstandard seals.
Package Size
10 - 10 size50 - 50 size100 - 100 size
Model Series
F - Indicating type inlet filter
3 4 5 876 91 2
1
2
3
5
6
7
8
9
10
10
4
62
Dimensions
203,2(8.00)
203,2(8.00)
50,0(1.97)
52,4(2.06)
31,7(1.25)
31,7(1.25)
Inlet port
Outlet port
25,4(1.00)
∅
26,2(1.03)
13,1(0.52)
26,2(1.03)
two places
Wrenchflats
.375-16 UNC 2B thd.22,5 (0.88) deep4 holes, 2 places
70,0(2.75)
35,0(1.38)
139,7(5.50)
82,6(3.25)
Memoryreset knob
Cover can be rotatedin 90� increments tosuit installation.
Visualindicator
53,8(2.12)1/2” NPTF thd.
177,8 (7.00) min.4 wires
For proper air bleedoperation, center linemust be horizontal withinlet port pointed down.
10FA Model Series mm (inch)
70,0(2.75)
114,3(4.50)
Inlet and Outlet Port Threads
Element Areacm2 (in2) Pipe Thread* SAE Straight Thread Tube Size NPTF Flange* Welded Flange
419.4 (65) 1” NPTF G1 (1” BSPF) 1.312-12 UN 1.000 FLI-8-08P-10 FLI-8-08W-10
*Not recommended
153,9(6.06)
Threaded Ports
SAE Flange Ports
Mechanical Indicator Electrical Indicator
In
Out
In
Out
57,2(2.25)
215,9(8.50)
Clearancerequired forremoval ofcartridge
35,0(1.38)
63
Dimensions
304,8(12.00)
57,1(2.25)
50F* Model Seriesmm (inch)
Inlet and Outlet Port Threads SAE Flange Port Dimensions
Element SAEArea Pipe Straight Tube NPTF Welded
Model cm2 (in2) Thread* Thread Size Flange* Flange A B C D E
50FB 645,2 (100) 11/2” 1.875-12 UN 1.50 FLI-12-12P-10 FLI-12-12W-10 35,7 (1.41) 17,8 (0.70) 35,1 (1.38) 69,8 (2.75) 38,1 (1.50)
50FC 1419,4 (220) 2” 2.500-12 UN 2.00 FLI-16-16P-10 FLI-16-16W-10 42,9 (1.68) 21,3 (0.84) 38,9 (1.53) 77,8 (3.06) 50,8 (2.00)
50FD 1419,3 (220) 21/2” – – FLI-20-20P-10 FLI-20-20W-10 50,8 (2.00) 25,4 (1.00) 44,4 (1.75) 88,9 (3.50) 63,5 (2.50)
*Not recommended
D
57,1(2.25)
57,1(2.25)
87,4(3.44)
114,3(4.50)
57,15(2.25)
196,8(7.75)
114,3(4.50)
Memoryreset knob
Inlet port
Outlet port
53,8(2.12)
1/2” NPTFthd.
165,1(6.50)
Cover can be rotatedin 90� increments tosuit installation.
Visualindicator
For proper air bleedoperation, center linemust be horizontal withinlet port pointed down.
C
B
∅ E two places
Wrenchflats
.500-13 UNC 2B thd.26,9 (1.06) deep4 holes, 2 places
255,8(10.07)
358,6(14.12)
Clearancerequired forremoval ofcartridge
Out
Threaded Ports
SAE Flange Ports
Mechanical Indicator Electrical Indicator
In
Out
In
Out
A
82,6(3.25)
304,8(12.00)
177,8 (7.00) min.4 wires
114,3(4.50)
64
Dimensions
381,0 (15.00)
419,1(16.50)
Clearancerequired forremoval ofcartridge
100F* Model Series mm (inch)
Inlet and Outlet Port Threads SAE Flange Port Dimensions
Element SAEArea Pipe Straight Tube NPTF Welded
Model cm2 (in2) Thread* Thread Size Flange* Flange A B C D E
100FE 2580,6 (400) 3” – – FLI-24-24P-10 FLI-24-24W-10 62,0 (2.44) 31.0 (1.22) 53,1 (2.09) 106,4 (4.19) 76,2 (3.00)
100FF 2580,6 (400) 31/2” – – – FLI-28-28W-10 69,8 (2.75) 35,1 (1.38) 60,4 (2.38) 120,6 (4.75) 88,9 (3.50)
*Not recommended
76,2 (3.00)
D
73,1 (2.88)
98,6 (3.88)
152,4 (6.00)
76,2 (3.00)
259,6 (10.22)
146,0(5.75)
Memoryreset knob
Inlet port
Outlet port
53,8(2.12)
1/2” NPTFthd.
227,1 (8.94)
Cover can be rotatedin 90� increments tosuit installation.
Visualindicator
For proper air bleedoperation, center linemust be horizontal withinlet port pointed down.
C
B
∅ E two places
Wrenchflats
.625-11 UNC 2B thd.33,3 (1.31) deep4 holes, 2 places
331,0(13.03)
152,4(6.00)
Out
Threaded Ports
SAE Flange Ports
Mechanical Indicator Electrical Indicator
In
Out
In
Out
A
113,5(4.47)
381,0 (15.00)
177,8 (7.00) min.4 wires
73,1 (2.88)
65
MEDIUM PRESSURE FILTERS
H331 Series Filters�� Flows to 23 L/min (6 USgpm) – Pressures to 210 bar (3000 psi)
Rated flow: 23 L/min (6 USgpm)
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Pressure rating: Operating 210 bar (3000 psi) Proof 310 bar (4500 psi) Burst 517 bar (7500 psi) Fatigue 100 bar (1500 psi)
Material: Head Aluminum alloy
2024-T351 Bowl Aluminum alloy
2024-T351
Dry weight: (Approximate) 1.9 Kg (4.2 lbs)
Design Specifications
� Positive sealing poppet type bypassfor reliability and zero leakage.
� Compact, low weight design for usewith servo or proportional pilotvalves.
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� High collapse H-Pak elementavailable for use with non-bypassapplications.
Features and Benefits
Filter seriesH331
Port
Valve options
1 - Non-Bypass 4 - Bypass set at 50 ± 5 PSID
cracking pressure
NOTE: Use option 1 only with 4500PSID collapse filter element (H-Pak).
O - 3/4-16UNF SAE-8 straight thd.
(1/2” tube)
Element collapse rating1 - 150 PSID (C-Pak)5 - 4500 PSID (H-Pak)
NOTE: Use 1 only with bypass valve ormonitored �P indicator.
Housing Model Code
3 4 5 8761 2
Valve options4 �P indicator5
Use with1(Non–Bypass)
4(Bypass 50 PSID)
�P indicator & receptacle optionsFirst designator (Indicator type)cont’d
Second designator (Electricalreceptacle)
B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman
receptacle (GSA) plug 3 pole plus ground
N - No receptacle – Use with visual�P indicator.
NOTE: Order P-227533-01 forreplacement aluminum idicator plug.
5
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Element construction
C - C-Pak media (grade 3,5,10)H - H-Pak media (grade 3,10)�*�� 0�#�� 7�����7�2��"�2�� �
�����"�4�7�$������"#������
Fluid cleanliness ratings
Code Fluid cleanliness level
030510
16/14/12 or better18/16/14 or better20/18/15 or better
6
7
8
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
D - Electrical/visual �P 35 ± 5 PSIDE - Electrical/visual �P 100 ± 12 PSIDG - Electrical/visual �P 35 ± 5 PSID
thermal lockout (100�F)J - No �P indicatorL - Visual �P indicator w/ 35 ± 5 PSID
actuation & thermal lockout (100�F)M - Visual �P indicator w/ 35 ± 5 PSID
actuation, thermal lockout (100�F) & surge control
O - Visual �P indicator w/100 ± 12 PSID actuation & thermal lockout (100�F)
P - Electrical �P switch w/100 ± 12 PSID actuation thermal lockout (100�F) & surge control
R - Electrical �P switch w/ 35 ± 5 PSID actuation control
�P indicator & receptacle options
First designator (Indicator type)
5
T - Electrical �P switch w/100 ± 12 PSID actuation
W- Electrical/visual �P 100 � 12 PSID thermal lockout (100�F)
Y - Electrical/visual �P 35 ± 5 PSIDthermal lockout (100�F) & surge control
Z - Electrical/visual �P 100 ± 12 PSIDthermal lockout (100�F) & surgecontrol
E, J, O, P, T, W & Z
D, J, L, M, RY & G
4
1
2
3
66
Dimensions
Filter Housing Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9
H331 Housingmm (inch)
19,1(0.75)
132 max.(5.20)
92,08 (3.63)
38,10(1.50)
76,20 (3.00)
182,22 max.(7.17)
Outlet port(See modelcode)
222,3 (8.75) req’dfor element &bowl removal
38,10 (1.50)
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
4
8
12
16
2 4 600
Torque bowl to 20 Nm (15 lb. ft)max.
00 2 64
20
30
40
50
60
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
76,20(3.00)
�P IndicatorSee Model Code
27,94 max. (1.10)visual indicator
54,61 max. (2.15)electrical indicator
6,8 (0.27) dia.mounting holes(2 places)
101.60(4.00)
4,06 (.16)
Access plug for By-pass valve.(SAE-6 socket plug)
Inlet port(See modelcode)
10
Pre
ssur
e dr
op –
Bar
Flow Rate - L/min
Pre
ssur
e dr
op –
Bar
Bypass Valve Flow Data
Flow Rate - L/min
1
2
3
4
0
8 16 240
8 16 240
0,3
0,6
0,9
1,2
0
67
303 Series Replacement Filter Elements
Design specifications Filter Element Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9
Rated flow: 23 L/min(6 USgpm )
Construction Proprietarymedia: C-Pak or H-Pak
construction
Dimensionsmm (inch)
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Element Model Code
Filter element
V303 - For use with H/M331 series filters
Element collapse rating
1 - 150 PSID5 - 4500 PSID (H-Pak only)
NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1
2
Seal material
B - Buna-NV - Viton-A
Viton is a registered trademark of E.I. DuPont
3
Element construction
C - C-Pak media (grade 3, 5,10)H - H-Pak media (grade 3,10)
4
5 Fluid cleanliness ratings
Code Fluid cleanliness level
030510
16/14/12 or better18/16/14 or better20/18/15 or better
41,3 dia.nominal(1.62 )
(3.44)
87,3
O-ring AS568-212Flow Rate - USgpm
Pre
ssur
e dr
op -
PS
ID
0
2
4
6
8
0
10
2 4 61 3 5
03
05
10
3031 C-Pak element
Flow Rate - USgpm
Pre
ssur
e dr
op -
PS
ID
00
10
2 4 61 3 5
03
1020
30
40
3035 H-Pak element
3 4 51 2
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - L/min
Flow Rate - L/min
Pre
ssur
e dr
op -
Bar
Pre
ssur
e dr
op -
Bar
1
2
3
0
0
0,4
0,7
0,1
8 16 244 12 200
8 16 244 12 200
68
H340 Series Filters Flows to 91 L/min (24 USgpm) – Pressures to 210 bar (3000 psi)
� Positive sealing poppet type bypassfor reliability and zero leakage.
� High density anodized aluminumhead and bowl.
� Compact, low weight design for usewith servo or proportional valves.
� Conforms to HF2 specifications (#2bowl length).
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Two bowl length options for designflexibility.
� Replacement elements available inC-Pak media.
� High collapse H-Pak elementavailable for use with non-bypassapplications.
Design SpecificationsMeets HF2 filter specifications whenused with bowl length No. 2.
Features and Benefits Housing Model Code
Dry weight: (Approximate) Bowl length 1 1,2 Kg (2.70 lb) Bowl length 2 1,7 Kg (3.85 lb)
Rated flow: 45 L/min (12 USgpm)91 L/min (24 USgpm)(with bowl length Code 2)
Pressure rating: Operating 210 bar (3000 psi) Proof 310 bar (4500 psi) Burst 517 bar (7500 psi) Fatigue 100 bar (1500 psi)
Material: Head Aluminum alloy 2024-T351Bowl Aluminum alloy
2024-T351
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Filter series
H340
Port options
Valve options
1 - Non-Bypass4 - Bypass set at 50 ± 5 PSID cracking
pressure.NOTE: ������������������ �������������������������������������
+�� 1.062-12UN SAE-12 straight thread (3/4” tube)
��� � 7)������ "��"'
Element collapse rating
1 - 150 PSID��,�����"�2�*���&����������0�����"�2�
NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1
2
3
4
�P indicator & receptacle options
First designator (Indicator type)
Second designator (Electrical receptacle)
B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual �P
indicator only(See page 7 for wiring diagram.)
5
NOTE:Order P-227533-01 for replacement aluminum indicator plug.
Seal materialB - Buna-N V - Viton-A
Viton is a registered trademark of E.I. DuPont
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
Fluid cleanliness ratingsCode Target fluid
cleanliness level
030510
16/14/12 or better18/16/14 or better20/18/15 or better
6
7
9
Valve options4 �P indicator5
Use with
1 (Non–Bypass) J,B,N or S
4 (Bypass 50 PSID) J,A,L or R
8
3 4 5 876 91 2
+�� ������������ ������$�����$����������������� ���"
!�� ������������ ������$�����$���=�������������� ���"
��� ������"#�����
��� !�� ������"#������$������������������ ���"�%������������ ���������
,�� !�� ������"#������$����=�������������� ���"�%������������ ���������
��� �����������"#������$����������������� ���"
��� ��������������$�����$����=�������������� ���"
��� �>�4?��>6�.� �����&��
��� +�.4?����6���@ +����?�
@�0�+
"�� ,�����'�#���4��4����
-�� 0�����'�#���4���
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
S50 -Head sub-assembly only (No element, bowl or indicator)
69
Dimensions
31,8(1.25)98,5
(3.88)
Filter Housing/Bypass ValveFlow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravityof � 0.9(See page 6 for specific gravitycorrections for pressure drop.)
H340 Housingmm (inch)
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
201816141210
86420
0 2 6 8 10 12 14 16 18 20 22 24Refer tomodelcode
38,1(1.50)
76,2(3.00)
39,7(1.50)
50,8 (2.00)
101,6(4.00)
79,4 (3.12)� 0.13 (.005)
25,4 (1.00)
Inlet port
IN OU
T
Outlet port
101,6(4.00)
.265 dia.thruhole (2)
Torque bowl to15 lb. ft(20 Nm) max.
31,7(1.25)
52,5(2.07)
17,0 (0.67)
25,4 C’bore for –117 sizeO-rings –17,5dia. fluid hole 2 places
Outlet
.350 dia. thru 1.80 deepmounting holes (4)5/16 – 18 x 2.50 longgrade 8 bolts are recom-mended for .63 enlarge-ment (4 req’d).
31,7(1.25)
15,8 (0.62)
44,4(1.75)
101,6 (4.00)
88,9 (3.50)
76,2 (3.00)
Indicator location
Inlet
Subplate Mounting
Housing
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
60
40
20
00
Bypass Valve
50 PSID Valve
80
50
6 12 18 24
95,2 (3.75) Clearancefor bowl/element removal
1.062-12UNSAE-12 st. thd.(3/4” tube)
1.062-12UNSAE-12 st. thd.(3/4” tube)
70
304 Series Replacement Filter Elements
O-ringAS568-214
Design Specifications Filter Element Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
Dimensionsmm (inch)
Element Model Code
Filter element
V304 - For use with 340 & 440 seriesfilters
Element collapse rating
1
2
Seal material
B - Buna-NV - Viton-A
Viton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
030510
16/14/12 or better18/16/14 or better20/18/15 or better
6
Construction Proprietary & media: C-Pak or H-Pak
construction
Rated flow: 45 L/min (12 USgpm)(with bowl length 1)91 L/min (24 USgpm)(with bowl length 2)
Temp range: - 54�C to +135�C(- 65�F to +275�F)
44,5 dia.nominal (1.75)
Refer tomodelcode
3041 C-Pak 101 (4) length
Flow Rate - USgpmPre
ssur
e dr
op -
PS
ID
2 4 6 8 10 1200
51015
20030510
Pre
ssur
e dr
op -
PS
ID
3041 C-Pak 203 (8) length
2 4 6 8 10 1200
51015
20030510
141618 20 22
3 4 5 61 2
1 - 150 PSID (C-Pak only)5 - 4500 PSID (H-Pak only)
NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1 - 161,8 (6.37) 101 (4 )2 - 257,8 (10.15)* 203 (8) * HF2
C - C-Pak (grade 3, 5, 10)H - H-Pak (grade 3,10)
3045 H-Pak 101 (4) length
Pre
ssur
e dr
op -
PS
ID
2 4 6 8 10 1200
102030
40 03
10
3045 H-Pak 203 (8) length
2 4 6 810120010203040
141618 20 22
50
Pre
ssur
e dr
op -
PS
ID
03
10
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
71
H350 Series Filters Flows to 189 L/min (50 USgpm) – Pressures to 210 bar (3000 psi)
Design Specifications
Features and Benefits Housing Model Code
Filter seriesH350
Element collapse rating
1
2
Meets HF3 filter specifications whenused with bowl length No. 2.
� Conforms to HF3 specifications(#2 bowl length).
� Plated nodular iron head and platedforged steel bowl for easy systemanalysis and superior corrosionresistance.
� Diagnostic port in head.
� Safety grip on bowl.
� Forged hex on bowl for easy elementchanges.
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Two bowl length options for designflexibility.
� Replacement elements available inC-Pak media.
� High collapse H-Pak elementavailable for use in non bypassapplications.
� Accepts Eco-Pak coreless elements.
9��#�8��$* =��A��"��+��B�')��
(with bowl length Code 1)�?=�A��"�����B�')��
(with bowl length Code 2)
����� ������"'*
��C)����"' +���7��������)���
������8 ����7���&����)���
��< ��� ��.�7���.����)���
�����' � ����7��������)���
/�����*
��0�# ,���"�# ������"
��<�$� �����
(��)��"'�* ���&�,����-����,
���>�������-+.����
��2�$��'��*��1))��3�����
��<�$����"'���� �4?�5'��?6&���7���
��<�$����"'���+ &4��5'��=6=���7��
3 4 5 876 91 2
1 - 150 PSID4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored � P indicator.
PortB - 1.312-12UN SAE-16 straight
thread (1” tube)
3
Valve options1 - Non-Bypass 3 - Bypass set at 22�3 PSID
cracking pressure4 - Bypass set at 50�5 PSID
cracking pressure6 - Bypass set at 90�10 PSIDNOTE: Use option 1 with 3000 PSIDcollapse filter element only (H-Pak)
4
Valve options4 �P indicator5
Use with1(Non–Bypass)
E,J,O,P,T,W or Z
3(Bypass 25 PSID)
C,F,J,K,Q or X
4(Bypass 50 PSID)
D,G,J,L,M,R or Y
R - Electrical �P switch w/35�5 PSIDactuation
T - Electrical �P switch w/100�12 PSID actuation
U - Electrical �P switch w/70�7 PSID actuation
V - Electrical/visual �P indicator w/70�7 PSID thermal lockout (100�F)
W- Electrical/visual �P 100�12 PSIDthermal lockout (100�F)
X - Electrical/visual �P 15�4 PSIDthermal lockout (100�F) & surge control
Y - Electrical/visual �P 35�5 PSIDthermal lockout (100�F) & surge control
Z - Electrical/visual �P 100�12 PSIDthermal lockout (100�F) & surge control
�P indicator & receptacle optionsFirst designator (Indicator type)5
A - Visual �P indicator with 70�7 PSIDw/surge control
B - Electrical/visual �P 70�7 PSIDw/surge control
C - Electrical/visual �P 15�4 PSIDD - Electrical/visual �P 35�5 PSIDE - Electrical/visual �P 100�12 PSIDF - Electrical/visual �P 15�4 PSID
thermal lockout (100�F)G - Electrical/visual �P 35�5 PSID
thermal lockout (100�F)I - Visual �P indicator w/70�7 PSID
thermal lockout (100�F)J - No �P indicatorK - Visual �P indicator w/15�4 PSID
actuation & thermal lockout (100�F)L - Visual �P indicator with 35�5 PSID
actuation & thermal lockout (100�F)M - Visual �P indicator w/ 35 ± 5 PSID
actuation, thermal lockout (100�F) & surge control
O - Visual �P indicator w/100�12 PSIDactuation & thermal lockout (100�F)
P - Visual �P indicator w/100 ± 12PSID actuation & thermal lockout(100�F) & surge control
Q - Electrical �P switch w/15�4 PSIDactuation
Second designator (Electricalreceptacle)B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual �P
indicator(See page 7 for wiring diagram.)
Assy. lengthmm (inch)
1 - 216 (8.5) 102 (4)2 - 310 (12)* 203 (8)*HF3
Element construction
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Element lengthmm (inch)
Fluid cleanliness ratingsCode Fluid cleanliness level
C - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3,5,10)H - H-Pak (grade 3,10)
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
7
8
9
NOTE: Order P-227533-01 for replacementaluminum indicator plug.
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
6(Bypass 90 PSID)
A,B,I,J,U or V
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
S50 -Head sub-assembly only (No element, bowl or indicator)
72
Dimensions
105,7(4.16)
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressure drop.)
H350 Housingmm (inch)
123,2(4.85)111,8
(4.40)
15,9(0.62)
35,0 Max.(1.38)
27,4(1.08)
50,8 min. (2.00) req’d forelement & bowl removal
Refer to model code
Drain plug9/16-18 UNF SAE-6 str. thd.
Bleed plug7/16-20 UNF SAE str. thd.
Safety gripSafety grip
Out In
0 25 50 750
1
2
3
4
5
6
Flow Rate - USgpm
1” SAE-16
Pre
ssur
e dr
op –
PS
ID
22 PSID cracking
50 PSID cracking
0
20
40
60
0 10 20 30 40 50 60Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
�P indicator
33,5 (1.32)
28,6(1.12)
57,2 (2.25 )
5/16 -18 UNC-3B(2 places)
InletOutlet
31,8 (1.25)
Housing Bypass Valve
Torque bowl to 15 lb. ft(20 Nm) max.
CAUTIONBefore servicing theelement, the bleed plugin filter housing must be
loosened to relieve pressure. Thiswill minimize fluid overflow.
80
100
25
50
90 90 PSID cracking
120110
65
32
�
63,5(2.50)
35,0 (1.38)
29,9 (1.18)
Visual: 44,5 (26.9)Electrical: 71,1 (2.80)
73
602 Series Replacement Filter Elements
Rated flow: 95 L/min (25 USgpm)(with bowl length code 1)189 L/min (50 USgpm)(with bowl length code 2)
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Construction Proprietary & media: C-Pak, E-Pak or
H-Pak construction
Design Specifications Filter Element Flow Datamm (inch)Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
Element Model Code
Filter element
Element collapse rating
1
2
Seal materialB - Buna-NV - Viton-A
Viton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
Meets or exceeds HF3 filter elementspecifications when used with bowllength No. 2.
Dimensions mm (inch)
05
101520
0 10 20 305 15 25 35 40
2530 03
0510
C20
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
6021 C-Pak/E-Pak element102 (4) length
05
101520
0
2530 03
0510
C20
5 15 25 35 45 55 65 75Pre
ssur
e dr
op –
PS
ID
6021 E-Pak/C-Pak element203 (8) length
010203040
0 10 20 305 15 25 35 40
50 03
10
Pre
ssur
e dr
op –
PS
ID
6024 H-Pak element 102 (4) length
01020304050
5 15 25 35 45 55 65 750
03
10
Pre
ssur
e dr
op –
PS
ID
6024 H-Pak element 203 (8) length
3 4 5 61 2
V602 - For use with 061, 620, 350 & OFR 30 series filters
1 - 150 PSID4 - 3000 PSID (H-Pak only)
NOTE: Use 1 only with bypass valve ormonitored � P indicator.
1 - 216 (8.5) 102 (4)2 - 308 (12)* 203 (8)*HF3
C - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5,10)H - H-Pak (grade 3, 10)
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
C01
Refer tomodel code
79,8(3.14)dia. typ
E-PakO-ring perAS-568-135C-Pak/H-PakO-ring perAS568-131
1,27 (0.05 ) max.
74
H360 Series Filters Flows to 114 L/min (30 USgpm) – Pressures to 210 bar (3000 psi)
Design Specifications
Features and Benefits Housing Model Code
Filter seriesH360
Port
Valve
Element collapse rating
1
2
3
4
�P indicator & receptacle optionsFirst designator (Indicator type)
Second designator (Electrical receptacle)B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual �P
indicator
5
NOTE: Order P-227533-01 for replacementaluminum indicator plug.
Seal material
Bowl lengthmm (inch)
Element construction
Fluid cleanliness ratings
6
7
9
8
1 - Non-Bypass
� Easy installation into hydraulic system.
� Protects sensitive valves frommalfunction due to contamination.
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Two bowl length options for designflexibility.
� Diagnostic port in head for easy systemanalysis.
� Plated forged steel bowl with drain port(hex design) for easy element changes.
� Bleed plug in bowl and drain plug inhousing minimizes fluid overflow whenservicing the element.
� Bolt kits available to attach theservovalve and sandwich plate to themanifold.
ApproximateDry weight: Bowl length 1 4,5 Kg (10 lb) Bowl length 2 6,3 Kg (14 lb)
Rated flow: 57 L/min (15 USgpm)114 L/min (30 USgpm) with bowl length 2
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water,water-in-oil andphosphate ester fluids.
Pressure rating: Operating 210 bar (3000 psi) Proof 310 bar (4500 psi) Burst 965 bar (14000 psi) Fatigue 138 bar (2000 psi)
Materials ofconstruction: Head Steel Bowl Forged steel
Temp range: - 54�C to + 135�C(- 65�F to + 275�F)
3 4 5 876 91 2
1 - 150 PSID 4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with monitored �P indicator.
W - Sandwich plate mount – vertical bowl
D - Electrical/visual �P 35�5 PSIDE - Electrical/visual �P 100�12 PSIDG - Electrical/visual �P 35�5 PSID
thermal lockout (100�F)J - No �P indicatorL - Visual �P indicator with 35�5 PSID
actuation & thermal lockout (100�F)M - Visual �P indicator with 35�5
PSID actuation & thermal lockout (100�F) & surge control
O - Visual �P indicator w/100�12 PSIDactuation & thermal lockout (100�F)
P - Visual �P indicator with 100�12 PSID actuation & thermal lockout (100�F) & surge control
R - Electrical �P switch with 35�5 PSID actuation
T - Electrical �P switch with 100�12 PSID actuation
W - Electrical/visual �P 100�12 PSID thermal lockout (100�F)
Y - Electrical/visual �P 35�5 PSID thermal lockout (100�F) & surge control
Z - Electrical/visual �P 100�12 PSID thermal lockout (100�F) & surge control
V - Viton-AViton is a registered trademark of E.I. DuPont
1 - 250,2 (9.85)) max.2 - 342,4 (13.48) max.
C - C-Pak (grade 3,5,10)H - H-Pak (grade 3,10)
Code Fluid cleanliness level
030510
11/14/12 or better18/16/14 or better20/18/15 or better
NOTE: Two mounting bolts are supplied withfilter to attach filter housing to sandwich plate.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
(See page 7 for wiring diagram.)
S50 -Head sub-assembly only (No element, bowl or indicator)
75
Dimensions
46,0 (1.81)
Filter Housing Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressuredrop.)
H360 Housingmm (inch)
25,4(1.00)
54,7(2.16)
15,9 (0.63) flowPort dia. 2 plcs.
43,2(1.70)
28.7(1.13)
69,3(2.73)
76,2(3.00)
101,6 (4.00)
130,3(5.13)
23,1 (0.91)
Outlet port
Inlet port
�P Indicatorport both sides
Drain plug (SAE-2)
111,2(4.35)
Bleed plug (SAE-6)
4” bowl 250,2 (9.85)8” bowl 342,4 (13.48)
0 5 10 15 20 250
10
20
25
30
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
30
5
15
Servo-Pro filters are suppliedwith AS568-017 viton sealsand two 7/16-20 UNF boltsfor mounting the filter housingto the sandwich plate.
11,51 (0.453) diameter (2 places)
Torque bowl to 15 lb. ft (20 Nm) max.
CAUTIONBefore servicing theelement, the bleed plugin filter housing must be
loosened to relieve pressure. Thiswill minimize fluid overflow.
�
69,8 (2.75)
34,9 (1.37)19,3 (0.76)
76,2 (3.00)
Sandwich Plate
15,9(0.63)
76
601 Series Replacement Filter Elements
Design Specifications Filter Element Flow Datamm (inch)Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity gravity corrections for pressure drop.)
Dimensionsmm (inch)
Element Model Code
Filter element
V601 - For use with 360 or 610series filters
Element collapse rating1 - 150 PSID 4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1
2
Seal material
B - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
Code
030510
16/14/12 or better18/16/14 or better20/18/15 or better
6
Construction Proprietary & media: H-Pak or C-Pak
construction
Temp range: - 54�C to +135�C(- 65�F to + 275�F)
50,8 dia.(2.00)
O-ring perAS568-119
Refer to modelcode
1,27 (.050 ) max.
6011 C-Pak element 101,6 (4) length
0
10
20
30
0Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
2 4 6 8 10 12 14
03
0510
0
10
0 2 4 6 8 10 12 14
20
30
6014 H-Pak element 101,6 (4) length
Pre
ssur
e dr
op –
PS
ID03
10
0
10
20
30
0 10 20 30 40 50
6011 C-Pak element 203,0 (8) length
Pre
ssur
e dr
op –
PS
ID
03
05
10
0
10
0
20
30
10 20 30 40 50Pre
ssur
e dr
op –
PS
ID
03
10
6014 H-Pak element 203,0 (8) length
3 4 5 61 2
1 - 250,2 (9.85) 101 (4)2 - 342,4 (13.48) 203 (8)
C - C-Pak (grade 3,5,10)H - H-Pak (grade 3,10)
Fluid cleanlinesslevel
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids.Optional seals availablefor phosphate esters.
Rated flow: 57 L/min (15 USgpm) with bowl length 1114 L/min (30 USgpm) with bowl length 2
77
Servovalve Sandwich Plates
Design Specifications
SM4–20 P-233639 BKDGFN01624 1/4-20 x 4-1/2”SM4–40 P-233640 BK590735 5/16-18 x 5-1/4”CETOP3 P-334115 * *CETOP5 P-334116 * *
aa bb cc dd eeSM4–20 2,5 8,6 16,0 8,3 13,5
(0.10 DIA) (0.34 DIA) (0.63 DIA) (0.33 DIA) (0.53 DIA)4,0
(0.16 DP)
SM4–40 4,06 14,7 16,0 8,3 22,1(0.16 DIA) (0.58 DIA) (0.63 DIA) (0.33 DIA) (0.87 DIA)
A B C D E F G H I J K L M N O P QSM4–20 120,7 50,8 65,0 30,2 50,8 44,5 22,4 12,7 9,9 63,5 25,7 13,0 25,4 50,8 46,0 23,1 101,6
(4.75) (2.00) (2.56) (1.19) (2.00) (1.75) (0.88) (0.50) (0.39) (2.50) (1.01) (0.51) (1.00) (2.0) (1.81) (0.91) (4.00)
SM4–40 139,7 57,2 60,5 32,5 63,5 92,2 22,4 20,6 20,6 63,5 25,7 13,0 25,4 63,5 22,4 23,1 127,0(5.50) (2.25) (2.38) (1.28) (2.50) (3.63) (1.81) (0.81) (0.81) (2.50) (1.01) (0.51) (1.00) (2.50) (1.81) (0.91) (5.00)
MLK
I
E
B
Sandwich plates are available to mountthe Servo-Pro filter with Vickers SM4-20and SM4-40 series servovalves. Inaddition, standard sandwich plates areavailable for mounting either CETOP3or CETOP5 proportional valves.
A
C
F
G
H
J
D
N
O
PQ
1
2
3
4
bb
aa
cc
ee
dd
7/16–20 UNF3/4 deep (2)
32
32 32
SM4-20 SM4-40
Steel
Weight
Kg (lbs.) Kg (lbs.)
5,9 (13.0) 7,3 (16.0)
SandwichPlateMaterial
Bolt KitSandwichPlate
Bolt SizeModel
Model
Model
Sandwich plates are supplied with Vitonseals. Sandwich plate mounting boltsare available and must be orderedseparately. Refer to table below for boltkit numbers.
SM4-40 sandwich plate shown
*Bolt kits will vary with valves and sandwich plates. Refer to Vickers Bulletin 690.
NOTE: SM4-20 cover must be rotated90� for use with this assembly.
Dimensionsmm (inch)
78
Dimensions
63,5 (2.50)
CETOP 3
CETOP 5
25,9(1.02)
1
2
34
32
3276,2 (3.00)32,5(1.28)
8,9 (0.35)
40,3(1.60)
30,2(1.20) 21,5
(0.85)
16,6(0.65)
31,0(1.22)
15,4 (0.61)5,3 (0.21)
76,2(3.00)
38,1(1.50)
46,0(1.81)
63,5 (2.50)26,6(1.01)
13,0 (0.51) 25,4(1.00)
∅ 3,2 (0.12) Dowel pin.50 long
∅ 12,7(0.50)4 plcs.
∅ 7,1(0.28)4 plcs.
.6250 Dia. 1.78 deep2 plcs.
.4375-20 UNF 3/4 deep 2 plcs.
∅ 7,85 (0.31) – 8,0 (0.32)Hole no. 1,2 & 3 drilled thru
50,8(2.00)
1
2
3
4
32
32
∅ 7,1 (0.28)4 plcs.
∅ 15,9(0.63) 5 plcs.
54,0(2.13)
37,3(1.47)
127,0(5.00)
63,5(2.50)
46,0(1.81)
23,0(0.91)
.6250 Dia.1.78 deep2 plcs.
.4375–20 UNF 3/4 deep 2 plcs.
36,5(1.44)
27,0(1.06)
16,7(0.66)
3,2(0.13)
101,6 (4.00)46,0 (1.81)39,7 (1.56)
24,6 (0.97)11,7 (0.46)
5
∅ 11,1 (0.4375) Hole no.1,2,3 & 4 drilled thru
26,6(1.01)
13,0 (0.51) 25,4 (1.00)
Proportional Valve Sandwich Platesmm (inch)
23,0(0.91)
79
H440 Series Filters Flows to 91 L/min (24 USgpm) – Pressures to 280 bar (4000 psi)
� Positive sealing poppet type bypassfor reliability and zero leakage.
� Nodular iron head and forged steelbowl for maximum durability.
� Compact design for use with servo orproportional valves.
� Conforms to HF2 specifications (#2bowl length).
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Two bowl length options for designflexibility.
� High collapse H-Pak elementavailable for use with non-bypassapplications.
Design SpecificationsMeets HF2 filter specifications whenused with bowl length No. 2.
Features and Benefits Housing Model Code
Dry weight: (Approximate) Bowl length 1 Bowl length 2
Rated flow: 45 L/min (12 USgpm)(with bowl length Code 1)91 L/min (24 USgpm)(with bowl length Code 2)
Pressure rating: Operating 280 bar (4000 psi) Proof 420 bar (6000 psi) Burst 700 bar (10000 psi) Fatigue 170 bar (2450 psi)
Material: Head Cast nodular iron Bowl Forged steel
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Filter seriesH440
Port options
Valve options
1 - Non-Bypass4 - Bypass set at 50 ± 5 PSID cracking
pressure.6 - Bypass set at 90 � 10 PSID cracking
pressureNOTE: ������������������ �������������������������������������
+�� 1.062-12UN SAE-12 straight thread (3/4” tube)
��� � 7)������ "��"'
Element collapse rating
1 - 150 PSID��,�����"�2�*���&����������0�����"�2�
NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1
2
3
4
�P indicator & receptacle options
First designator (Indicator type)
Second designator (Electrical receptacle)B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual �P
indicator only
5
NOTE: Order P-227533-01 for replacement aluminum indicator plug.
Seal materialB - Buna-N V - Viton-AViton is a registered trademark of E.I. DuPont
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
Fluid cleanliness ratingsCode Target fluid
cleanliness level
03051020
16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
7
9
Valve options4 �P indicator5
8
3 4 5 876 91 2
��� �?=��.6�?� �����&���@�� +?�����6?� +����?�@0�+�*�� 0�#�� 7�����7�2��"�2�� �
�����"�4�7�$������"#������
"�� ,�����'�#���4��4���-�� 0�����'�#���4���
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
The table assumes limited ingression/single pass of pump flow throughelement. For detailed assistance, seeVickers Guide to SystemicContamination Control or contact yourlocal Vickers representative.
Use with1(Non–Bypass)
E,J,O,P,T,W or Z
4 (Bypass 50 PSID)
D,G,J,L,M,R or Y
6(Bypass 90 PSID) A,B,I,J, U or V
A - Visual �P indicator w/70 � 7 PSIDw/surge control
!�� ������������ �����.����.�����w/surge control
��� ������������ ����������������
$�� ������������ ������������+�������� ������������ �����������������
������������ ���������.�� !�� ������"#������$����.����.������
������������ ������������ ������"#�������� !�� ������"#������$����������������
�� ���"4������������� ���100�F)M - Visual �P indicator with 35 � 5 PSID
actuation, thermal lockout (100�F)& surge control
O - Visual �P indicator w/100�12 PSIDactuation & thermal lockout (100�F)
P - Visual �P indicator with 100 � 12 PSID actuation, thermal lockout (100�F) & surge control
R - Electrical �P switch with 35 � 5 PSID actuationT - Electrical �P switch with 100 � 12
PSID actuationU - Electrical �P 70 � 7 PSID
actuationV - Electrical/visual �P indicator with
70 � 7 PSID thermal lockout (100�F)W- Electrical/visual �P 100 � 12 PSID
thermal lockout (100�F) Y - Electrical/visual �P 35 � 5 PSID
thermal lockout (100�F) & surge control
Z - Electrical/visual �P 100 � 12 PSIDthermal lockout (100�F) & surge control
80
Dimensions
Visual: 75,7(2.98) max. Electrical: 97,5(3.84) max.
31,7(1.25) typ.
52,3(2.06)
Drill ∅ 8,9(.35) hole
thru4 plcs.
typ.
44,4(1.75)
H440 Housing
79,4(3.12)
25,4(1.00)
Flow Rate - USgpm
00 5 10 15 25 3020
20
40
60
80
100
Filter Housing Flow Data
Bypass Valve Flow Data
Flow versus pressure drop
150 SUS (32cSt) oil with a specific gravity of � 0.9(See page 6 for specific gravity corrections forpressure drop.)
Subplate Mounting
81,3 (3.20)46,2 (1.82)
50,8 (2.00)
101,6 (4.00)
∅ 69,9 (2.75)
Refer tomodel code
63.5 (2.50) min. required forelement and bowl removal Drain plug
SAE-6
∅ 6,7 (.265)Dia. hole thrumountingholes, 2 plcs.
�P Indicator(Refer tomodel code)
Inlet and OutletPort SAE-12
88,9 (3.50)
15,9(.62)
17,0 (0.67)
104,6 (4.12)
31,7 (1.25)
∅ 17,5 .69 hole ∅ 25,4(1.00) c’bore for -117O-ring 2 plcs.
mm (inch)
mm (inch)
0
4
8
12
16
20
4 8 12 16 20 240
InletOutlet
Flow Rate - USgpm
Visual:81,8 (3.22) max. Electrical:03,6 (4.08) max.
Torque bowlto 15 lb. ft (20 Nm)max.
Construction plugs notfor flow connection.
121,9 (4.80)
Pre
ssur
e dr
op -
PS
IDP
ress
ure
drop
- P
SID
InletPort
Outlet Port
24,6(.97)
57,2(2.25)
81
304 Series Replacement Filter Elements
O-ringAS568-214
Design Specifications Filter Element Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
Dimensionsmm (inch)
Element Model Code
Filter element
V304 - For use with 340 & 440 series filters
Element collapse rating
1
2
Seal material
B - Buna-NV - Viton-A
Viton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
030510
16/14/12 or better18/16/14 or better20/18/15 or better
6
Construction Proprietary & media: C-Pak or H-Pak
construction
Rated flow: 45 L/min (12 USgpm)(with bowl length Code 1)91 L/min (24 USgpm)(with bowl length Code 2)
Temp range: - 54�C to +135�C(- 65�F to +275�F)
44,5 dia.nominal (1.75)
Refer tomodelcode
3041 C-Pak 101 (4) length
Flow Rate - USgpm
Pre
ssur
e dr
op -
PS
ID
2 4 6 8 10 1200
51015
20030510
Pre
ssur
e dr
op -
PS
ID
3041 C-Pak 203 (8) length
2 4 6 8 10 1200
51015
20030510
141618 20 22
3 4 5 61 2
1 - 150 PSID (C-Pak only)5 - 4500 PSID (H-Pak only)
NOTE: Use 1 use only with bypass valve ormonitored �P indicator.
1 - 161,8 (6.37) 101 (4 )2 - 257,8 (10.1)* 203 (8) * HF2
C - C-Pak (grade 3, 5, 10)H - H-Pak (grade 3,10)
3045 H-Pak 101 (4) length
Pre
ssur
e dr
op -
PS
ID
2 4 6 8 10 1200
102030
40 03
10
3045 H-Pak 203 (8) length
2 4 6 810120010203040
141618 20 22
50
Pre
ssur
e dr
op -
PS
ID
03
10
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
82
H451 Series Filters Flows to 568 L/min (150 USgpm) – Pressures to 310 bar (4500 psi)
Rated flow: 189 L/min (50 USgpm)with bowl length 3379 L/min (100 USgpm)with bowl length 6568 L/min (150 USgpm)with bowl length 7
Housing & Compatible with mostElement petroleum oil, waterCompatibility: glycol, oil-in-water
and water-in-oil fluids. Optional seals available for phosphate esters.
(��)��"'�* ���&�,����-����,
���>�������-+.����
����� ������"'*
��C)����"' ����7���&����)���
������8 &>��7���>.���)���
��< ��� =���7���������)���
�����' � �=��7���+.���)���
/�����*
��0�# � ���������"
��<�$� ,�7�"������
��2�$��'��*��1))��3�����
��<�$����"'���� +�4&�5'����>6���7�
��<�$����"'���> �.4��5'���?+6���7�
��<�$����"'���. &=4��5'�����=6���7�
Design Specifications
Features and Benefits Housing Model Code
Filter seriesH451
1
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Conforms to HF4 specifications (allbowl lengths).
� Plated seamless drawn steel bowl andplated nodular iron head and cap forcorrosion resistance.
� Diagnostic port in cap for easy systemanalysis.
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Three bowl length options for designflexibility.
� Drain port in base.
� Rugged positive seating bypass valvewith heavy duty guided and retainedspring for zero leakage.
� Replacement elements available inC-Pak or H-Pak media.
� Accepts Eco-Pak coreless elements.
Meets HF4 specifications
3 4 5 876 91 2
Port options
Valve options1 - Non-Bypass4 - Bypass set at 50 � 5 PSID
cracking pressure6 - Bypass set at 90 � 10 PSID
cracking pressure
Element collapse rating
1 - 150 PSID 4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator.
D - 1.875-12UN SAE-24 straight thread(11/2” tube)
E - 11/2” SAE 4-bolt split flng. Code 61R - 11/2” SAE 4-bolt split flng. Code 62S - Subplate mounting
2
3
4
Valve options4 �P indicator5
Use with1(Non–Bypass)
E,J,O,P,T,W or Z
4(Bypass 50 PSID)
D,G,J,L,M,R or Y
�P indicator & receptacle options
First designator (Indicator type)
5
+�� !�� ������"#������$����.����.�����$� �'����"����
!�� ������������ �����.����.�����$� �'����"����
��� ������������ ����������������
$�� ������������ ������������+�����
��� ������������ ���������������������������� ���������
.�� !�� ������"#������$.����.������������������ ���������
��� ������"#�����
��� !�� ������"#������$������������� ���"�%������������� ���������
/�� !�� ������"#������$������������� ���"�%������������� ���������"#�� �'����"����
0�� !�� ������"#������$�������+�������� ���"�%������������� ���������
��� !�� ������"#������$�������+�������� ���"�%������������� ����������"#�� �'����"����
��� ���������������$�����$�������������� ���"
1�� ��������������$�����$�������+�������� ���"�
2�� ��������������$�����$����.����.������� ���"�
�� ������������ ������"#������$.����.������������������ ���������
3� ������������ ������������+����������������� ���������
��� ������������ ���������������������������� ����������%�� �'����"����
4�� ������������ ������������+������������������ ����������%�� �'����"����
Second designator (Electricalreceptacle)!�� ��)�"�<�#�0�����"��&���+�-�� �� �&�>������0������"�����)�����
�D�1�)� '�����)�����)� ��'�� "#,�� ������)����6�B���$������� �
����"#����������)'��.�8���$���"'�#�'��6�
Seal material!���< "�
���!���"�1
Viton is a registered trademark of E.I. DuPont
6
Assy. lengthmm (inch)
5����??4.����6��� ++=��=�
����>+.4=��+&6.�� &�.���?�
����?>�4>���&6��� >?>��+.�
1��������0�&��)���8�����"�6
Element lengthmm (inch)
7
Element construction"��� ,�����'�#����4�4��4���4�+��
$�� �������4��4����
-��� 0�����'�#���4���
8
Fluid cleanliness ratingsCode Fluid cleanliness level�5*��
�� ���"'��"�2�>��6������7������?��6������7�����+���6�*����7�����++�76������7�����
9
6(Bypass 90 PSID)
A,B,I,J,U or V
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative. ���!�"�#�����$$%�&&��'���������������(��(���#��������()�
S50 -Head sub-assembly only (No element, bowl or indicator)
83
Dimensions
Inlet Port45,9 (1.81) C’bore for-130 O-ring38,1 (1.50) flow port Dia.(both)
35,8(1.41)
H451 Housingmm (inch)
71,6(2.82)
114,3(4.50)
72,9(2.87)
146,0(5.75)
161,8(6.37)
63,5(2.50)
7,62(0.30)
127,0(5.00)
22,3 (0.88)
57,1(2.25)
3.75 max. (elect. �P indicator)2.00 max. (elect./vis. �P indicator)
1.00 max. (visual �P indicator)
.562 dia. thru 4 plcs.
InletRefer to model codefor port options
OutletPort on opposite face
Refer to model code
139,7(5.50)19,0
(0.75 )38,1 Hex (1.50)
80,8(3.18)
Filter housing/Bypass Valve flow data
Subplate mounting
Outlet
50,8(2.00)
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressuredrop.)Housing
0 25 50 75 100 125 1500
4
8
12
16
20
24
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
Torque to 55 lb. ft (40 Nm)
Torque to 250 lb. ft (184 Nm)
50 PSID cracking
0
20
40
60
0 10 20 30 40 50 60Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
Bypass Valve
80
100
50
90 90 PSID cracking
120110
65
11/2” flg. SAE 4-bolt
11/2” SAE-24
114,3(4.50)
127,0(5.00)
71,4(2.81)
84
405 Series Replacement Filter Elements
E-PakO-ring perAS-568-135
0
5
10
1520
0
03
10
20 40 60 80 100
4054 H-Pak 457 (18) length
Pre
ssur
e dr
op –
PS
ID
Design SpecificationsMeets HF4 filter specifications
Filter Element Flow Datamm (inch)
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 7 for viscosity corrections for pressure drop.)
Element Model CodeFluid cleanliness ratings
CodeTarget fluidcleanliness level
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
6
Construction Proprietary E-Pak, C-Pak& media: or H-Pak construction
Temp range: - 54�C to +135�C(- 65�F to +275�F)
4051 E-Pak/C-Pak 229 (9) length
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
0
468
10
2
03
0510C20
0
12
10 20 30 40 50
02468
1012
20 40 60 80 100 120 140
03
0510C20
0
Pre
ssur
e dr
op –
PS
ID
4051 E-Pak/C-Pak 686 (27) length
0
468
10
2
03
0510C20
12
0 20 40 60 80 100
4051 E-Pak/C-Pak 457 (18) length
Pre
ssur
e dr
op –
PS
ID
0
5
10
15
2003
10
0 10 4020 30 50
4054 H-Pak 229 (9) length
6020 40 80 100 120 140
03
10
0
4054 H-Pak 686 (27) length
Pre
ssur
e dr
op –
PS
IDP
ress
ure
drop
– P
SID
Filter element
V405 - For use with OFR60/120, 451,HL15 and HL16 series filters
Element collapse rating
1 - 150 PSID4 - 3000 PSID (H–Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1
2
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
C - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5, 10)H - H-Pak (grade 3,10)
4
5
3 - 386 (15) 229 (9)6 - 625 (24) 457 (18)7 - 864 (34) 686 (27)
3 4 5 61 2
Replacement Element ConnectorVickers 228 mm (9 inch), 457 mm (18inch) and 686 mm (27 inch) elementsare single elements. This easeshandling and element replacement.
228 mm (9 inch) elements may bestacked rather than using one 457 mm(18 inch) or 686 mm (27 inch) element.
Dimensions mm (inch)
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
0
5
10
15
20
3
B - Buna-NV - Viton-A
Seal material
Order P-227567-01 replacementelement connector when stackingtwo or more 228 mm (9 inch)elements.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpm Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
C01
C01
C01
100,3(3.95)dia. typ
Refer tomodel code)
Rated flow: 189 L/min (50 USgpm)with bowl length 3379 L/min (100 USgpm)with bowl length 6568 L/min (150 USgpm)with bowl length 7
85
HIGH PRESSURE FILTERS
H610 Series Filters Flows to 208 L/min (55 USgpm) – Pressures to 414 bar (6000 psi)
Design Specifications
Features and Benefits Housing Model Code
Filter seriesH610
1
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Plated forged steel bowl and platednodular iron head for corrosionresistance.
� Optional subplate mounting.� Diagnostic port in head for easy
system analysis.� Unique bypass valve design (simple
and reliable).� Flexible mounting capability with
optional heavy duty brackets.
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Two bowl length options for designflexibility.
� High collapse H-Pak element availablefor use with non-bypass applications.
Dry weight: (Approximate) Bowl length 1 4,4 Kg (9.72 lb) Bowl length 2 5,6 Kg (12.33 lb)
Rated flow: 95 L/min (25 USgpm)with bowl length 1208 L/min (55 USgpm)with bowl length 2
Pressure rating: Operating 414 bar (6000 psi) Proof 620 bar (9000 psi) Burst 1379 bar (20000 psi) Rated fatigue 241 bar (3500 psi)
Material: Head Cast iron Bowl Forged steel
Temp range: - 54�C to +135�C(- 65�F to +275�F)
3 4 5 876 9 101 2
Element collapse rating1 - 150 PSID4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator.
2
�&����&8� &�#A - 1.062-12UN SAE-12 str. thd. (3/4”
tube)B - 1.312-12UN SAE-16 str. thd. (1” tube)F - 1” SAE 4-bolt split flange Code 61M - 1” SAE 4-bolt split flange Code 62S - Subplate mounting
3
��9��&8� &�#1 - Non-Bypass4 - Bypass set at 50 � 5 PSID
cracking pressure6 - Bypass set at 90 � 10 PSID
cracking pressure
NOTE: Use option 1 only with 3000 PSIDcollapse filter element.
4
Valve options4 �P indicator5
Use with1(Non–Bypass)
E,J,O,P,T,W or Z
4(Bypass 50 PSID)
D,G,J,L,M,R or Y
�P indicator & receptacle optionsFirst designator (Indicator type)5
A - Visual �P indicator w/70 � 7 PSIDwith surge control
B - Electrical/visual �P 70 � 7 PSIDwith surge control
D - Electrical/visual �P 35 � 5 PSIDE - Electrical/visual �P 100 � 12 PSIDG - Electrical/visual �P 35 � 5 PSID
thermal lockout (100�F)I - Visual �P indicator with 70 � 7 PSID
thermal lockout (100�F)J - No �P indicator��� !�� ������"#������$����
�������������� ���"�%������������ ���������
M - Visual �P indicator with 35 � 5 PSIDactuation & thermal lockout (100�F)and surge control
O - Visual �P indicator w/100�12 PSIDactuation & thermal lockout (100�F)
P - Visual �P indicator with 100 � 12 PSID actuation & thermal lockout (100�F) and surge control
R - Electrical �P switch with 35 � 5 PSID actuation
T - Electrical �P switch with 100 � 12PSID actuation
U - Electrical �P switch with 70 � 7PSID actuation
V - Electrical/visual �P indicator w/70 � 7 PSID thermal lockout (100�F)
W- Electrical/visual �P 100 � 12 PSIDthermal lockout (100�F)
Y - Electrical/visual �P 35 � 5 PSIDthermal lockout (100�F) and surge control
Z - Electrical/visual �P 100 � 12 PSIDthermal lockout (100�F) and surge control
B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual
�P indicator(See page 7 for wiring diagram.)
Second designator (Electricalreceptacle)
NOTE: Order P-227533-01 for replacement aluminum indicator plug.
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Bowl lengthmm (inch)
1 - 171,5 (6.75) 102 (4)2 - 264,2 (10.40) 203 (8)S50 -Head sub-assembly only (No
element, bowl or indicator)
Brackets
Element lengthmm (inch)
6
7
8
Element constructionC - C-Pak (grade 3, 5,10)H - H-Pak (grade 3, 10)
Fluid cleanliness ratingsCode Fluid cleanliness level
9
10
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
6(Bypass 90 PSID)
A,B,I,J, U or V
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
1 - No bracket(Order #P-426225-01)
16/14/12 or better18/16/14 or better20/18/15 or better
030510
86
Dimensions
Inlet 30,2 (1.19) C’bore for -120 O-ring21,4 (0.84) flow port dia.
H610 Housingmm (inch)
Drain plug9/16-18-UNFSAE str. thd.
138,9 (5.47)
94,5(3.72)
31,8 hex (1.25)
Safety gripTorque bowl to15 lb. ft (20 Nm).
Bleed plug7/16-20UNFSAE str. thd.
����"#�����&��
63,5 min. (2.50) req’d for element and bowl removal
47,2 (1.86)7/16-14 UNC-2Bthd. thru 4 holes
Outlet port
65,0(2.56)
57,9 (2.28)
141,2(5.56)
76,2(3.00)
28,6(1.12)
57,2(2.25)
11,9 Dia (.470 )Mtg. bkt. holes(4 places)
22,4 (0.88)
50,8 (2.00)
40,1(1.58 )
26,9(1.06)
6,1(0.24)
87,4(3.44)
Inlet
47,8(1.88)
61,2(2.41)
&��
69,9(2.75)
�
In
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of ≤ 0.9(See page 6 for specific gravity corrections for pressure drop.)
� �� +� �� &� �� >��&
?
�+
�>
+�
+&
Flow Rate - USgpm
1” SAE-16straight thread
3/4”-12 straight thread
Pre
ssur
e dr
op –
PS
ID 1” SAE 4-boltsplit flange
Housing
Subplate Mountingmm (inch)
52,3(2.06)
57,1 (2.25)
13,8 (0.54)
61,1 (2.40)
26,1 (1.03)
38,1 (1.50)
7/16-14 UNC-2B thd.4 holes thru
7/16-14 UNC-2B thd.2 holes .88 deep min.
28,6 (1.12)
Outlet30,2 (1.19) C’borefor - 120 O-ring21,4 (0.84)flow port dia.
94,5 (3.72)
Mounting BracketOrder Part numberP-426225-01(See page 98 for mounting bracket installation.)
CAUTIONBefore servicing theelement, the bleed plugin filter housing must be
loosened to relieve pressure. Thiswill minimize fluid overflow.
50 PSID cracking
0
20
40
60
0 5 15 25 35 45 55Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
Bypass Valve
80
100
50
90 90 PSID cracking
120110
65
�
Refer tomodel code
87
601 Series Replacement Filter Elements
9�8�������#�����#�
Design Specifications Filter Element Flow Datamm (inch)Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of ≤ 0.9(See page 7 for viscosity corrections for pressure drop.)
Element Model Code
Filter element
Element collapse rating
1
2
Seal material3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
030510
16/14/12 or better18/16/14 or better20/18/15 or better
6
B - Buna-N���!���"�1
Viton is a registered trademark of E.I. DuPont
,�"��� ����" ���)�����2�
%���#�* ,�������0;��
��"��� ����"
(��)��"'�* ���&�,����-����,
���>�������-+.����
6011 C-Pak element 101 (4) length
Flow Rate - USgpmPre
ssur
e dr
op –
PS
ID
0
10
20
30
0 2 4 6 8 10 12 14
03
0510
05
1015
0 2 4 6 8 10 12 14
03
10202530356014 H-Pak element 101 (4) length
Pre
ssur
e dr
op –
PS
ID
0
10
20
30
0 5 15 25 35 45
03
05
10
55Pre
ssur
e dr
op –
PS
ID 6011 C-Pak element 203 (8) length
05
1015
0
03
1020253035
10 20 305 15 25 35 40 45 50Pre
ssur
e dr
op –
PS
ID 6014 H-Pak element 203 (8) length
� ���# &�#������"���
��4?�#�6�+6���
C���"'�)��1��>?���=
�4+.���6������36
3 4 5 61 2
V601 - For use with 610 and 360series filters
1 - 150 PSID4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1 - 165 (6.5) 101,6 (4)2 - 259 (10) 203 (8)
C - C-Pak (grade 3, 5,10)H - H-Pak (grade 3,10)
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpm
Flow Rate - USgpm
Rated flow: 95 L/min (25 USgpm)with bowl length 1208 L/min (55 USgpm)with bowl length 2
88
S610 Series Filters Flows to 208 L/min (55 USgpm) – Pressures to 414 bar (6000 psi)
1 - 278,1 (10,9) 102 (4)2 - 370,3 (14.6) 203 (8)S50 -Head sub-assembly only (No
element, bowl or indicator)
Rated flow: 95 L/min (25 USgpm)with bowl length 1208 L/min (55 USgpm)with bowl length 2
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Pressure rating: Operating 414 bar (6000 psi) Proof 620 bar (9000 psi) Burst 1379 bar (20000 psi) Fatigue 221 bar (3200 psi)
Material: Head Cast nodular iron Bowl Forged steel
Dry weight: (Approximate) Bowl length 1 4,4 Kg (9.72 lb) Bowl length 2 5,6 Kg (12.33 lb)
Design Specifications
Features and Benefits Housing Model Code
Filter seriesS610
1
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Plated forged steel bowl and platednodular iron head for corrosionresistance.
� Diagnostic port in head for easysystem analysis.
� Unique bypass valve design (simpleand reliable).
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Two bowl length options for designflexibility.
� High collapse H-Pak element availablefor use with non-bypass applications.
� Side subplate mounting design.
3 4 5 876 9 101 2
Element collapse rating1 - 150 PSID4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator.
2
�&��
S - Subplate mounting3
��9��&8� &�#
1 - Non-Bypass4 - Bypass set at 50 � 5 PSID
cracking pressure6 - Bypass set at 90 � 10 PSID
cracking pressureNOTE: Use option 1 only with 3000 PSIDcollapse filter element.
4
Valve options4 �P indicator5
Use with
1(Non–Bypass)
E,J,O,P,T,W or Z
4(Bypass 50 PSID)
D,G,J,L,M,R or Y
�P indicator & receptacle optionsFirst designator (Indicator type)5
A - Visual �P indicator with 70 � 7 PSIDwith surge control
B - Electrical/visual �P 70 � 7 PSIDwith surge control
D - Electrical/visual �P 35 � 5 PSIDE - Electrical/visual �P 100 � 12 PSIDG - Electrical/visual �P 35 � 5 PSID
thermal lockout (100�F)I - Visual �P indicator with 70 � 7 PSID
thermal lockout (100�F)J - No �P indicator��� !�� ������"#������$����
�������������� ���"�%������������ ���������
M - Visual �P indicator with 35 � 5 PSIDactuation & thermal lockout (100�F)and surge control
O - Visual �P indicator w/100�12 PSIDactuation & thermal lockout (100�F)
P - Visual �P indicator with 100 � 12 PSID actuation & thermal lockout (100�F) and surge control
R - Electrical �P switch with 35 � 5 PSID actuation
T - Electrical �P switch with 100 � 12PSID actuation
U - Electrical �P switch with 70 � 7PSID actuation
V - Electrical/visual �P indicator w/70 � 7 PSID thermal lockout (100�F)
W- Electrical/visual �P 100 � 12 PSIDthermal lockout (100�F)
Y - Electrical/visual �P 35 � 5 PSIDthermal lockout (100�F) and surge control
Z - Electrical/visual �P 100 � 12 PSIDthermal lockout (100�F) and surge control
B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual
�P indicator(See page 7 for wiring diagram.)
Second designator (Electricalreceptacle)
NOTE: Order P-227533-01 for replacementaluminum indicator plug.
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Bowl lengthmm (inch)
Brackets1 - No bracket
Element lengthmm (inch)
6
7
8
Element constructionC - C-Pak (grade 3,5,10)H - H-Pak (grade 3,10)
Fluid cleanliness ratings
Code Fluid cleanliness level
030510
16/14/12 or better18/16/14 or better20/18/15 or better
9
10
6(Bypass 90 PSID)
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
A,B,I,J, U or V
89
Dimensions
Refer tomodel code
45,7(1.80)
Outlet44,6 (1.75) C’borefor - 222 O-ring30,5 (1.20) flow port dia.(both ports)
S610 Housingmm (inch)
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of ≤ 0.9(See page 6 for specific gravity corrections for pressure drop.)
� �� +� �� &� �� >��&
?
�+
�>
+�
+&
Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
Pre
ssur
e dr
op –
PS
ID
139,9 (5.51)
94,9(3.74)
∅ 88,9 (3.50)
59,9(2.36)
109,9(4.33)
189,2(7.45)
148,0 (5.83)
∅ 69,3 (2.73)
52,1(2.05)
SAE-12 FillPlug(2 places)
∅ 22,9 (0.90) dia. thru4 places7/8 - 9 UNC x 2.50 longgrade 8 bolts for 1.20enlargement are recommended (4 req’d)Torque to 185-250 lb. ft(250-270 Nm)
Housing
Inlet
32,0 (1.26)
Torque bowl to15 lb. ft (20 Nm) max.
SAE-6 Drain Plug
S610 Subplate Mount50 PSID cracking
0
20
40
60
0 5 15 25 35 45 55Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
Bypass Valve
80
100
50
90 90 PSID cracking
120110
65
�P Indicator
69,9(2.75)
31,0(1.22)
6,09(0.24)
47,5(1.87)
63,5 min. (2.50) req’d for element and bowl removal
90
601 Series Replacement Filter Elements
9�8�������#�����#�
Design Specifications Filter Element Flow Datamm (inch)Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of ≤ 0.9(See page 7 for viscosity corrections for pressure drop.)
Element Model Code
Filter element
Element collapse rating
1
2
Seal material3
Bowl lengthmm (inch)
Element construction
Element lengthmm (inch)
4
5
Fluid cleanliness ratings
CodeTarget fluidcleanliness level
030510
16/14/12 or better18/16/14 or better20/18/15 or better
6
B - Buna-N����!���"�1
Viton is a registered trademark of E.I. DuPont
,�"��� ����" ���)�����2�
%���#�* ,�������0;��
��"��� ����"
(��)��"'�* ���&�,����-����,
���>�������-+.����
6011 C-Pak element 101 (4) length
Flow Rate - USgpmPre
ssur
e dr
op –
PS
ID
0
10
20
30
0 2 4 6 8 10 12 14
03
0510
0
10
0 2 4 6 8 10 12 14
03
1020
30
6014 H-Pak element 101 (4) length
Pre
ssur
e dr
op –
PS
ID
0
10
20
30
0 10 20 30 40 50
03
05
10
Pre
ssur
e dr
op –
PS
ID 6011 C-Pak element 203 (8) length
0
10
0
03
1020
30
10 20 30 40 50Pre
ssur
e dr
op –
PS
ID 6014 H-Pak element 203 (8) length
� ���# &�#������"���
��4?�#�6�+6���
C���"'�)��1��>?���=
�4+.���6������36
3 4 5 61 2
V601 - For use with H610, S610 andH360 series filters
1 - 150 PSID4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator.
1 - 165 (6.5) 101,6 (4)2 - 259 (10) 203 (8)
C - C-Pak (grade 3, 5,10)H - H-Pak (grade 3,10)
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpm
Flow Rate - USgpm
Rated flow: 95 L/min (25 USgpm)with bowl length 1208 L/min (55 USgpm)with bowl length 2
91
H620 Series Filters Flows to 568 L/min (150 USgpm) – Pressures to 414 bar (6000 psi)
Design Specifications
Features and Benefits Housing Model Code
Filter seriesH620
Element collapse rating
1
2
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Conforms to HF3 specifications (#2bowl length).
� Plated nodular iron head and platedforged steel bowl for corrosionresistance.
� Reverse flow valve option available forhydrostatic applications.
� Diagnostic port in head for easysystem analysis.
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Four bowl length options for designflexibility.
� Flexible mounting capability withoptional heavy duty brackets.
� Unique bypass valve design (simpleand reliable).
� Replacement elements available inC-Pak media.
� High collapse H-Pak elementavailable for use with non by-passapplications.
� Accepts Eco-Pak coreless elements.
Rated flow: 157 L/min (40 USgpm)with bowl length 1284 L/min (74 USgpm) with bowl length 2454 L/min (120 USgpm) with bowl length 4568 L/min (150 USgpm) with bowl length 5
Meets HF3 specifications whenused with bowl length No. 2.
Pressure rating: Operating 414 bar (6000 psi) Proof 620 bar (9000 psi) Burst 965 bar (14000 psi) Fatigue 210 bar (3000 psi)Material: Head Cast iron Bowl Forged steel
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Dry weight: (Approximate) Bowl length 1 8,9 Kg (19.80 lb) Bowl length 2 11,0 Kg (24.30 lb) Bowl length 4 13,4 Kg (29.70 lb) Bowl length 5 18,0 Kg (39.78 lb)
1 - 150 PSID4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator
Port optionsB - 1.312-12UN SAE-16 str. thd. (1” tb.)C - 1.625-12UN SAE-20 str. thd. (11/4”
tube)D - 1.875-12UN SAE-24 str. thd. (11/2”
tube)E - 11/2” 4-bolt SAE split flng. Code 61G - 11/4” 4-bolt SAE split flng. Code 61Q - 11/4” 4-bolt SAE split flng. Code 62
3
Valve options1 - Non-Bypass 4 - Bypass set at 50 � 5 PSID
cracking pressure6 - Bypass set at 90 � 10 PSID8 - Reverse flow valve non-bypass9 - Reverse flow valve with bypass set
at 50 � 5 PSIDNOTE: Options 1 & 8, use only with 3000PSID collapse filter element.
4
Valve options4 �P indicator5
Use with1 & 8(Non–Bypass) E,J,O,P,T,W or Z
4 & 9(Bypass 50 PSID)
D,G,J,L,M,R or Y
�P indicator & receptacle optionsFirst designator (Indicator type)5
A - Visual �P indicator w/70 � 7 PSIDw/surge control
!�� ������������ �����.����.�����w/surge control
��� ������������ ����������������$�� ������������ ������������+�������� ������������ �����������������
������������ ���������.�� !�� ������"#������$����.����.������
������������ ���� ������"#�������� !�� ������"#������$����
�������������� ���"�%������������ ���������
M - Visual �P indicator with 35 � 5 PSIDactuation, thermal lockout (100�F)& surge control
O - Visual �P indicator w/100�12 PSIDactuation & thermal lockout (100�F)
P - Visual �P indicator with 100 � 12 PSID actuation, thermal lockout (100�F) & surge control
R - Electrical �P switch with 35 � 5 PSID actuationT - Electrical �P switch with 100 � 12
PSID actuationU - Electrical/visual �P 70 � 7 PSID
actuationV - Electrical/visual �P indicator with
70 � 7 PSID thermal lockout (100�F)W- Electrical/visual �P 100 � 12 PSID
thermal lockout (100�F) Y - Electrical/visual �P 35 � 5 PSID
thermal lockout (100�F) & surge control
Z - Electrical/visual �P 100 � 12 PSIDthermal lockout (100�F) & surge control
Second designator (Electricalreceptacle)B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug) 3 poles plus groundN - No receptacle – Use with visual
�P indicator(See page 7 for wiring diagram.)NOTE: Order P-227533-01 for replacementaluminum indicator plug.
3 4 5 876 9 101 2
Brackets6
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
7
Bowl lengthmm (inch)
1 - 180 (7) 101 (4)2 - 272 (11)* 203 (8)4 - 392 (15) 330 (13)5 - 490 (19) 406 (16)*HF3
Element lengthmm (inch)
8
Element constructionC - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5,10)H - H-Pak (grade 3, 10)
9
Fluid cleanliness ratingsCode Fluid cleanliness level0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
10
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
6(Bypass 90 PSID)
The table assumes limitedingression/single pass of pump flowthrough element. For detailed assistance,see Vickers Guide to SystemicContamination Control or contact yourlocal Vickers representative.
A,B,I,J, U or V
1 - No bracket(Order #P-426218-01)
S50 -Head sub-assembly only (No element, bowl or indicator)
92
Dimensions
76,2 min. (3.00) req’d for element and bowl removal
95,0(3.74)
184,4 (7.26)
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of � 0.9(See page 6 for specific gravity corrections for pressuredrop.)
H620 Housingmm (inch)
Drain plug SAE-6
77,7 max. (3.06)
31,8 hex (1.25)
Bowl torque to 15 lb. ft (20 Nm)
�P indicator
Refer tomodel code
26,9 typ(1.06)
50,8 ( 2.00)
46,0(1.81)
119,4 (4.70)
103,1 (4.12)
IN
Inletport
95,3(3.75)
59,7(2.35)
Outletport
73,2(2.88)
68,3(2.69)
Safetygrip
0 25 50 75 100 125 1500
48
1216
2024 1” SAE-16
11/4” SAE-20
11/4” flg.SAE 4-bolt
11/2” SAE-24
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
20�
Housing
Vent plugSAE-4
Mounting BracketOrder Part numberP-426218-01(See page 95 for mounting bracket installation.)
50 PSID cracking
0
20
40
60
0 30 60 90 120 150Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
Bypass Valve
80
100
50
90
90 PSID cracking120
110
65
66,7(2.62)
41,3(1.62)2 Places
7/16 -14 UNC 2B thd.mounting holes4 places
11/2” flg. SAE 4-bolt
136,5(5.37)2 places
93
602 Series Replacement Filter Elements
E-PakO-ring perAS-568-135C-Pak/H-PakO-ring perAS568-131
30
V602 - For use with 061, 350, 620and OFR30 series filters
6021 C-Pak/E-Pak element 203 (8) length
05
1015202530 03
0510
C20
5 15 25 35 45 55 65 750
Pre
ssur
e dr
op –
PS
ID
Design Specifications Filter Element Flow Datamm (inch)
Element Model Code
Filter element
Element collapse rating
1
2
Meets or exceeds HF3 elementspecifications when used with bowllength No. 2.
Construction Proprietary E-Pak, C-Pak& media: or H-Pak construction
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Flow Rate - USgpmPre
ssur
e dr
op –
PS
ID
6021 C-Pak/E-Pak element 101 (4) length
05
101520
0 10 20 305 15 25 35 40
2530 03
0510
C20
6021 C-Pak/E-Pak element 330 (13) length
Pre
ssur
e dr
op –
PS
ID
05
101520
0 40 80 12020 60 100
2530 03
0510
C20
Pre
ssur
e dr
op –
PS
ID
20 40 60 80 100 120 1400
03
05
10C20
6021 C-Pak/E-Pak element 406 (16) length
05
10152025
6024 H-Pak element 101 (4) length
6024 H-Pak element 203 (8) length
6024 H-Pak element 330 (13) length
6024 H-Pak element 406 (16) length
Pre
ssur
e dr
op –
PS
IDP
ress
ure
drop
– P
SID
Pre
ssur
e dr
op –
PS
IDP
ress
ure
drop
– P
SID
01020
30
40
0 10 20 305 15 25 35 40
50 03
10
0
1020
304050
5 15 25 35 45 55 65 750
03
10
010203040
0 40 80 12020 60 100
5003
10
01020304050
20 40 60 80 100 120 1400
03
10
3 4 5 61 2
1 - 150 PSID4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve.
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
$�������%&�#��'%� &�
Element lengthmm (inch)
C - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5,10)H - H-Pak (grade 3, 10)
4
5
1 - 180 (7) 101 (4)2 - 272 (11)* 203 (8)4 - 392 (15) 330 (13)5 - 490 (19) 406 (16)*HF3
Code Fluid cleanliness
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
Fluid cleanliness ratings6
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of 3 � 0.9(See page 7 for viscosity corrections for pressure drop.)
Dimensionsmm (inch)
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
Flow Rate - USgpm Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
C01
C01
C01Refer tomodel code
79,8(3.14)dia. typ
1,27 (0.05 ) max.
Rated flow: 157 L/min (40 USgpm) with bowl length 1284 L/min (74 USgpm) with bowl length 2454 L/min (120 USgpm) with bolw length 4568 L/min (150 USgpm) with bowl length 5
94
S620 Series Filters Flows to 568 L/min (150 USgpm) – Pressures to 414 bar (6000 psi)
Design Specifications
Features and Benefits Housing Model Code
Filter seriesS620
1
� Designed to comply with ANSIspecifications and ISO cleanlinessstandards.
� Plated forged steel bowl and platednodular iron head for corrosionresistance.
� Diagnostic port in head for easysystem analysis.
� Unique bypass valve design (simpleand reliable).
� Visual, electrical and electrical/visual�P indicator options for flexibility insystem design.
� Four bowl length options for designflexibility.
� Side subplate mounting design.� Accepts Eco-Pak coreless elements.
Dry weight: (Approximate) Bowl length 1 4,4 Kg (9.72 lb) Bowl length 2 5,6 Kg (12.33 lb)
Pressure rating: Operating 414 bar (6000 psi) Proof 620 bar (9000 psi) Burst 1379 bar (20000 psi) Fatigue 210 bar (3000 psi)
Material: Head Cast nodular iron Bowl Forged steel
Temp range: - 54�C to +135�C(- 65�F to +275�F)
3 4 5 876 9 101 2
Element collapse rating1 - 150 PSID4 - 3000 PSID (H-Pak only)NOTE: Use 1 only with bypass valve ormonitored �P indicator.
2
PortS – Subplate mounting3
��9��&8� &�#
1 - Non-Bypass 4 - Bypass set at 50 � 5 PSID
cracking pressure6 - Bypass set at 90 � 10 PSID8 - Reverse flow valve non-bypass9 - Reverse flow valve with bypass set
at 50 � 5 PSIDNOTE: Options 1 & 8, use only with 3000PSID collapse filter element.
4
�P indicator & receptacle optionsFirst designator (Indicator type)5
B - 5 pin Brad Harrison (41512)H - DIN 43650 or Hirschman receptacle
(GSA plug ) 3 poles plus groundN - No receptacle – Use with visual
�P indicator(See page 7 for wiring diagram.)
Second designator (Electrical receptacle)
NOTE: Order P-227533-01 for replacementaluminum indicator plug.
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
Brackets1 - No bracket6
7
Element constructionC - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5,10)H - H-Pak (grade 3,10)
Fluid cleanliness ratings
Code Fluid cleanliness level03051020
16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
9
10
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
U - Electrical/visual �P 70 � 7 PSIDactuation
V - Electrical/visual �P indicator with 70 � 7 PSID thermal lockout (100�F)
W- Electrical/visual �P 100 � 12 PSIDthermal lockout (100�F)
Y - Electrical/visual �P 35 � 5 PSIDthermal lockout (100�F) & surge control
Z - Electrical/visual �P 100 � 12 PSIDthermal lockout (100�F) & surge control
Rated flow: 157 L/min (40 USgpm)with bowl length 1284 L/min (74 USgpm) with bowl length 2454 L/min (120 USgpm) with bolw length 4568 L/min (150 USgpm) with bowl length 5
Valve options4 �P indicator5
Use with1 & 8(Non–Bypass) E,J,O,P,T,W or Z
4 & 9(Bypass 50 PSID)
D,G,J,L,M,R or Y
6(Bypass 90 PSID) A,B,I,J, U or V
A - Visual �P indicator w/70 � 7 PSIDw/surge control
!�� ������������ �����.����.�����w/surge control
��� ������������ ����������������$�� ������������ ������������+�������� ������������ �����������������
������������ ���������.�� !�� ������"#������$����.����.������
������������ ���� ������"#�������� !�� ������"#������$����
�������������� ���"�%������������ ���������
M - Visual �P indicator with 35 � 5 PSIDactuation, thermal lockout (100�F)& surge control
O - Visual �P indicator w/100�12 PSIDactuation & thermal lockout (100�F)
P - Visual �P indicator with 100 � 12 PSID actuation, thermal lockout (100�F) & surge control
R - Electrical �P switch with 35 � 5 PSID actuationT - Electrical �P switch with 100 � 12
PSID actuation
Bowl lengthmm (inch)
1 - 300 (11.8) 101 (4)2 - 392 (15.5)* 203 (8)4 - 512 (20.2) 330 (13)5 - 611 (24.1) 406 (16)*HF3
Element lengthmm (inch)
8
S50 -Head sub-assembly only (No element, bowl or indicator)
95
Dimensions
∅ 22,9 (0.90) dia. thru4 places7/8 - 9 UNC x 2.50 longgrade 8 bolts for 1.20enlargement are recommended (4 req’d)Torque to 185-200 lb. ft(250-270 N.m)
S620 Housingmm (inch)
Filter Housing/Bypass Valve Flow DataFlow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of ≤ 0.9(See page 6 for specific gravity corrections for pressure drop.)
139,9 (5.51)
94,9(3.74)
Refer toModelCode
59,9(2.36)109,9
(4.33)
30,9 (1.22)
52,0 (2.05)
47.5 (1,87)
∅ 105,6 (4.16)
∅ 120,6 (4.75)
SAE-12 Fill Plug(2 places)
SAE-6 Drain Plug
0 25 50 75 100 125 1500
48
12162024
Pre
ssur
e dr
op –
PS
ID
Flow Rate - USgpm
Housing
Inlet
Outlet
Torque bowl to15 lb. ft (20 Nm) max.
32,0 (1.26)
S620 Subplate Mount50 PSID cracking
0
20
40
60
0 30 60 90 120 150Flow Rate - USgpm
Pre
ssur
e dr
op –
PS
ID
Bypass Valve
80
100
50
90
90 PSID cracking120
110
65
6,1(0.24)
133,4(5.25)
63,5(2.50)required for element removal
179,3(7.06)
49,3(1.94)
Inlet44,6 (1.75) C’borefor - 222 O-ring30,5 (1.20) flow port dia.(both ports)
96
602 Series Replacement Filter Elements
Rated flow: 157 L/min (40 USgpm) with bowl length 1284 L/min (74 USgpm) with bowl length 2454 L/min (120 USgpm) with bolw length 4568 L/min (150 USgpm) with bowl length 5
Fluid Compatible with mostcompatibility: petroleum oil, water
glycol, oil-in-water andwater-in-oil fluids.Optional seals availablefor phosphate esters.
Temp range: - 54�C to +135�C(- 65�F to +275�F)
Construction Proprietary & media: E-Pak or H–Pak
construction
Refer tomodelcode
Design Specifications
Dimensions mm (inch)
79,8 dia.(3.14)
E-Pak O-ringper AS568-135C-Pak/H-PakO-ring perAS568-131
1,27 (0.05 ) max.
V602 - For use with 061, 350, 620& OFR30 series filters
Element Model Code
Filter element
Element collapse rating
1
2
3 4 5 61 2
1 - 150 PSID4 - 3000 PSID (H–Pak only)NOTE: Use 1 only with bypass valve.
Seal materialB - Buna-NV - Viton-AViton is a registered trademark of E.I. DuPont
3
Bowl lengthmm (inch)
$�������%&�#��'%� &�
Element lengthmm (inch)
C - C-Pak (grade 01, 3, 5, 10, 20)E - E-Pak (grade 3, 5,10)H - H-Pak (grade 3, 10)
4
5
1 - 300 (11.8) 101 (4)2 - 392 (15.5)* 203 (8)4 - 512 (20.2) 330 (13)5 - 611 (24.1) 406 (16)*HF3
Code Fluid cleanliness
0103051020
Flushing only16/14/12 or better18/16/14 or better20/18/15 or better22/19/16 or better
Fluid cleanliness ratings6
The table assumes limitedingression/single pass of pump flowthrough element. For detailedassistance, see Vickers Guide toSystemic Contamination Control orcontact your local Vickersrepresentative.
6021 C-Pak/E-Pak element 203 (8) length
05
1015202530 03
0510
C20
5 15 25 35 45 55 65 750
Pre
ssur
e dr
op –
PS
ID
Filter Element Flow Datamm (inch)
Flow Rate - USgpmPre
ssur
e dr
op –
PS
ID
6021 C-Pak/E-Pak element 101 (4) length
05
101520
0 10 20 305 15 25 35 40
2530 03
0510
C20
6021 C-Pak/E-Pak element 330 (13) length
Pre
ssur
e dr
op –
PS
ID
05
101520
0 40 80 12020 60 100
2530 03
0510
C20
Pre
ssur
e dr
op –
PS
ID
20 40 60 80 100 120 1400
03
05
10C20
6021 C-Pak/E-Pak element 406 (16) length
05
1015202530
6024 H-Pak element 101 (4) length
6024 H-Pak element 203 (8) length
6024 H-Pak element 330 (13) length
6024 H-Pak element 406 (16) length
Pre
ssur
e dr
op –
PS
IDP
ress
ure
drop
– P
SID
Pre
ssur
e dr
op –
PS
IDP
ress
ure
drop
– P
SID
01020
30
40
0 10 20 305 15 25 35 40
50 03
10
0
1020
304050
5 15 25 35 45 55 65 750
03
10
010203040
0 40 80 12020 60 100
5003
10
01020304050
20 40 60 80 100 120 1400
03
10
Flow versus pressure drop:150 SUS (32 cSt) oil with specific gravity of 3 � 0.9(See page 7 for viscosity corrections for pressure drop.)
Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
Flow Rate - USgpm Flow Rate - USgpm
Flow Rate - USgpmFlow Rate - USgpm
C01
C01
C01
97
Accessories
31,1(1.22)31,1
(1.22) 76,2 (3.00)
31,1(1.22)
A
1/8’’ NPT
Electrical Switch(See page 7 for electrical diagram.)
DIN 43650(Shown)
DIN 43650(Shown)
Connector A B
DIN 43650 48,2 (1.90) 34,9 (1.37)
Brad Harrison 59,2 (2.33) 45,7 (1.80)
Number Circuit1 Common2 Normally open3 Normally closedB
Housing Part Number
HL15, HL16, HT10, HT15, H021, H022, H023 P-234117-01 (18 psi) Brad HarrisonP-233051-01 (18 psi) DIN
HL15, HL16, H021, H022, H023 P-234118-01 (35 psi) Brad HarrisonP-233573-01 (35 psi) DIN
Gauge
10
60
30
barpsi
1/8’’ NPT
Housing Part Number
HL15, HL16, HT10, HT15, H021, H022, H023 P-232965-01 (0-60 psi) Color coded
HL15, HL16, H021, H022, H023 P-232974-01 (0-200 psi)
5/16 - 18 UNF thru (4) on 4.70 dia.BC equally spaced
∅ 89.0(3.50)
1/4 - 20 UNC thru (4) on 88.9 (3.5)BC equally spaced
7/16 - 20 UNFx 0.75 long
�
1/4 - 20 UNC x 0.5 long
�
Weld Flange
A
B
C
Dimensions
A B C7/16 - 20 UNFthru (4) on 6.25 dia.BC equally spaced
∅ 127,0(5.00)
181,0(7.12)
∅ 66.0(2.60)
106,7(4.20)
Housing
HL15, HL16P-232964-01
D D
� Recommended bolts
5/16 - 18 UNFx 0.75 long
�
dia.
dia.
140,0(5.50) dia.
E
E
12,7(0.50)
7,6(0.30)
12,7(0.50)
HT10P-235421
HT15P-333637
98
Accessories
11,9 (0.47) thru dia. (8 plcs.)
114,3(4.50)
73,0(2.88)
Mounting BracketH022 Housingmm (inch)
Order part numberP-233052-01
203,2 (8.00)69,8(2.75)
91,4(3.60)
160,5(6.32)
57,1(2.25)
127,0(5.00)
34,9(1.37) dia.
95,2(3.75)
25,4(1.00)
22,2(0.88)6,3
(0.25)
88,9(3.50)
12,7(0.50)
12,7 (0.50)
31,7(1.25)
23,4(0.92)
94,5(3.72)
Mounting BracketH610 HousingOrder part number P-426225-01
50,9 (2,00)
94,6 (3.72)
141,2 (5.56)
116,8(4.60)
28,6 (1.13)
98,5(3.88)
26,9 (1.06) typ.
12,1 (0.47)thru 8 plcs.
76,2 (3.00)
57,5 (2.25) typ.
136,5(5.37)
Mounting BracketH620 HousingOrder part number P-426218-01
50,9 (2,00)11,2(.44)
136,5 (5.38)
184,4(7.26)
127,0(5,00)
41,28 (1.62)
98,6(3.88)
26,9 (1.06) typ.
12,1 (0.47)thru 8 plcs.
23,9(0.94)
A A
View A-A
A A
View A-A
FilterCenterline
CL
99
Differential Pressure Indicator Selection Chart DifferentialPressureIndicator
�P(psi)
ThermalLockout
SurgeControl
041 /042
022 /023
061 330 /340
331 350 360 440 451 610 620 ModelNumber
PartNumber
FilterAssy.Code
15 X X X X X PV015T1N1A P-227505- K
35 X X X X X X X X X X X PV035T1N1A P-227508- L
35 X X PV035T1NM1A P-227509- L
Visual 35 X X X X X X X X X X X X PV035T1NS1A P-227510- M
70 X X X X X X X PV070N1NS1A P-234615- A
70 X X X X X X X PV070T1N1A P-233270- I
90 X X PV090T1NM1A P-227513- N
100 X X X X X X X X X X PV100T1N1A P-227514- O
100 X X X X X X X X X X PV100T1NS1A P-227515- P
15 X X X X PE015N1H1APE015N1B1A
P-227518- Q
35 X PE035N1HM1APE035N1BM1A
P-232108- R
Electrical 35 X X X X X X X X X X PE035N1H1APE035N1B1A
P-227524- R
70 X X X X X X PE070N1H1APE070N1B1A
P-234003- U
90 X PE090N1HM1APE090N1BM1A
P-232109- S
100 X X X X X X X X X PE100N1H1APE100N1B1A
P-227530- T
15 X X X X PD015N1H1APD015N1B1A
P-230297- C
15 X X X X X PD015T1H1APD015T1H1A
P-230300- F
15 X X X X X X PD015T1HS1APD015T1BS1A
P-230303- X
35 X PD035N1HM1APD035N1BM1A
P-230295- A
Electrical/ 35 X X X X X X X X X X PD035N1H1APD035N1B1A
P-230298- D
Visual 35 X X X X X X X X X X X PD035T1H1APD035T1B1A
P-230301- G
35 X X X X X X X X X X X X PD035T1HS1APD035T1BS1A
P-230304- Y
70 X X X X X X X PD070N1HS1APD070N1HS1A
P-234266- B
70 X X X X X X X PD070T1H1APD070T1B1A
P-233271- V
90 X PD090N1HM1APD090N1BM1A
P-230296- B
100 X X X X X X X X X PD100N1H1APD100N1H1A
P-230299- E
100 X X X X X X X X X X PD100T1H1APD100T1B1A
P-230302- W
100 X X X X X X X X X X X PD100T1HS1APD100T1BS1A
P-230305- Z
Part Number Suffix
For ordering seal material type andelectrical receptacle:
To basic kit part number add:-01 Buna-N seals-03 Viton-A seals
Followed by:N No receptacle. Use with all visual
(non-electrical) ∆P indicatorsH DIN 43650 or Hirschmann
receptacle (GSA plug) 3 pole,plus ground
B 5 pin Brad Harrison (41512)
Ordering InformationSelect the appropriate indicator for yourapplication from the above option chart.Add to this the part number suffix foryour seal compound and electricalreceptacle requirements.
Example:For filter series 041, electrical ∆P@ 35 +/- 5 PSID with Buna-N sealsand Hirschmann receptacle, order kit:P-227524-01H.
Indicators may be ordered by modelcode or part number.
100
SpecificationsMechanical
Material: Aluminum alloy.Consult Vickers for special materialrequirements.
Electrical
Switch: SPDTRating: 7 amps, resistive
4 amps, inductive2 amps, lamp load@ 28 VDC, 115 VAC 60 Hz
The electrical indicators automaticallyreset when the pressure differential isreduced below the set value.
The visual and electrical/visualindicators will remain in the indicatedposition after actuation. The indicatorsshould be manually reset after filterelement change.
�P Actuation Tolerance
Setting(PSID)
Tolerance(PSI)
15357090
100
�4�5�9�10�12
High-Performance Filter Housings
Visual (Mechanical) Indicator withpop-out button
Electrical Indicators with SPDTswitch and Electrical/VisualIndicator with pop-out button andSPDT switch
Port Plug
Part No. P-227533-01
PlasticCap
24,1(.95)max.
(Button extended)
66,5(2.62)max.
29,2(1.15)
(One size for all models).750-16UNF-2A thd.
.750-16UNF-2A thd.A
Dimension AElectrical Indicators with SPDT SwitchA = 48,3 (1.9) max.Button extension for Electrical/VisualIndicatorsA = 54,1 (2.13) max.
NOTES:
TLO @100�F (38�C) means the indi-cator will not signal below 60�F (16�C),and will signal above 100�F (38�C).
Mating connector to be furnished bycustomer.
Order #02-310053 Hirschmann stylemating plug.
.750-16UNF-2A thd.
101
Notes
Printed in U.S.A.5057.00/EN/0798/A