VETERINARY ANESTHESIA MACHINEPURCHASE GUIDE
FOR DISTRIBUTOR USE ONLY
VETERINARY ANESTHESIA MACHINE PURCHASE GUIDE
Dispomed is putting the spotlight on veterinary anesthesia machines. This quick and simple purchase guide will help you to determine your customer’s needs while considering the different characteristics of our anesthesia machines.
IDENTIFY YOUR CUSTOMER’S NEEDS
There are several types of anesthesia machines on the market today. Identifying your customer’s needs will help determine which machine will best suit his practice.
What space is available for the anesthesia machine?
• The smallest foot print for the anesthesia machine is the Coaxial and the Elite.
Do they prefer the machine to be wall-mount or mobile?
• The Optimax, Access 2, Compact and NRB are available wall-mounted. • If this is their first anesthesia machine, we strongly recommend a mobile unit, in order to move
it from one room to another, or for emergencies.
Do they use a veterinary monitor or an anesthesia ventilator during interventions?
• The Coaxial, Elite and the Optimax (mobile) come with a shelf for easy installation of a monitor.
Is hypothermia a concern during surgery?
• The Coaxial breathing circuit, found on the Coaxial and on the Optimax with coaxial absorber, preheats the gas inhaled by the patient thus reducing the possibility of hypothermia.
What kind of animals do they treat?
• If they treat a lot of small animals (cats or smaller), we recommend working with a Bain circuit adaptor, as an option to add to the anesthesia machine, because of its lower breathing resistance. There are no check valves or carbon dioxide absorbent granules in the circuit to increase resistance. This makes it the ideal accessory for small patients and for those with breathing problems.
Do they want to use more than one type of anesthetic gas?
• The only machine that allows for 2 vaporizers mounted at the same time is the Optimax (mobile or wall-mount).
Copyright © 2015 Dispomed ltd
RESEARCH THE PRODUCT
There are several types of anesthesia machines on the market today. Identifying your customer’s needs will help determine which machine will best suit his practice.
ModelModuflex Optimax
Moduflex Coaxial
Moduflex Elite
Moduflex Compact
Moduflex Access2
Moduflex NRB
Moduflex Labvet
Dimensions
Length64.77 cm (25.50”)
Width49.53 cm (19.50”)
Height137.16 cm (54”)
Length53.34 cm (21”)
Width49.53 cm (19.50”)
Height134.62 cm
(53”)
Length53.34 cm (21”)
Width49.53 cm (19.50”)
Height134.62 cm
(53”)
Length 68.58 cm
(27”)
Width 66.04 cm
(26”)
Height 138.43 cm (54.50”)
Length68.58 cm
(27”)
Width68.58 cm
(27”)
Height128.27 (50.5”)
Length 68.58 cm
(27”)
Width 66.04 cm
(26”)
Height 132.08 cm
(52”)
Length 30.48 cm (12”)
Width 30.48 cm (12”)
Height 33.20 cm (13”)
Shelf for accessories
Length49.53 cm
(19.5”)
Width30.48 cm (12”)
Length31.75 cm
(12.5”)
Width19.68 cm
(7.75”)
Length31.75 cm
(12.5”)
Width19.68 cm
(7.75”)
Optional Optional
Length22.86 cm (9”)
Width17.78 cm (7”)
No
Installation options
Mobile orwall-mount Mobile Mobile Mobile or
wall-mountMobile or
wall-mountMobile or
wall-mount Tabletop
Storage space
Yes No No No No No No
Coaxial circuit
Yes Yes No No No No No
Open circuit (Bain)
Optional Optional Optional Optional Optional Optional Optional
Semi-open circuit
(abosorber)Yes Yes Yes Yes Yes No No
Warranty 5 years 5 years 5 years 5 years 5 years 5 years 5 years
Copyright © 2015 Dispomed ltd
MODUFLEX OPTIMAX
Veterinary anesthesia machine for rebreathing and small animal applications. The Moduflex Optimax anesthesia machine is a work station that combines ingenuity, sophistication and common sense.
0.1 to 4 lpm O2 flowmeter.Rotary float and large scalefor easy readability.
Recessed flush valve to prevent accidental
activation.
Quick-connect fresh gasoutlet for easy and secure
switches between breathing circuits.
Drawer assembly.
Coaxial CO2 absorber.
Circuit and line pressure gauges.
Momentary closed feature integrated into our pop-offvalve.
Convenient instrument and upper monitor shelf
SELECTATECTM
compatiblity manifoldfor easy and quickinstallation of oneor two vaporizers.
Copyright © 2015 Dispomed ltd
MODUFLEX COAXIAL
Rebreathing and small animal applications. The only true Coaxial CO2 absorber on the market.
0.1 to 4 lpm O2 flowmeter.Rotary float and large scalefor easy readability.
CO2 absorber with integrated coaxial breathing circuit reduces patient heat loss, helps to humidify the inspired gas and reduce clutter.
Momentary closed feature integrated into our pop-off valve.
Recessed flush valve to prevent accidental activation.
Quick-connect fresh gas outlet for easy and secure switches
between breathing circuits.
Convenient monitor shelf.
SELECTATECTM
compatibility manifold foreasy and quick installation
of vaporizer.
Copyright © 2015 Dispomed ltd
MODUFLEX ELITE
Veterinary anesthesia machine for rebreathing and small animal applications. Its compact size and base shape, combined with its large castors, provide excellent mobility and stability.
0.1 to 4 lpm O2 flowmeter.Rotary float and large scalefor easy readability.
1500 ml CO2 absorber designed for easy and fast replenishing of sodalime. Condensation trap to prevent water build-up in sodalime.
Momentary closed feature integrated into our pop-off valve.
Recessed flush valve to prevent accidental activation.
Quick-connect fresh gas outlet for easy and secure switches
between breathing circuits.
Convenient monitor shelf.
SELECTATECTM
compatibility manifold foreasy and quick installation
of vaporizer.
Copyright © 2015 Dispomed ltd
MODUFLEX COMPACT
Veterinary anesthesia machine for rebreathing and small animal applications
SELECTATECTM
compatibility manifold foreasy and quick installationof vaporizer.
Momentary closed feature integrated into our pop-off valve.
1500 ml CO2 absorber designed for easy and fast replenishing of sodalime. Condensation trap to prevent water build-up in sodalime. Easy and efficient gas sealing.
Recessed flush valve to prevent accidental activation.
Quick-connect fresh gas outlet for easy and secure switches
between breathing circuits.
0.1 to 4 lpm O2 flowmeter.Rotary float and large scale
for easy readability.
Copyright © 2015 Dispomed ltd
MODUFLEX ACCESS2
Both the anesthesia machine head and the absorber head are precision machined to reduce the amount of connections which greatly reduces the risk of leaks.
Standard 1500 ml CO2 absorber designed for easy and fast replenishing of sodalime. Condensation trap to prevent water build-up in sodalime.
Cagemount compatibility manifold for easy and quick installation of vaporizer.
Recessed flush valve to prevent accidental activation.
Optional convenient monitor shelf.
0.1 to 4 lpm flowmeter with rotary float and large scale for
easy readability
Copyright © 2015 Dispomed ltd
0.1 to 4 lpm flowmeter with rotary float and large scale for easy readability
Recessed flush valve to prevent accidental activation.
Convenient monitor shelf
Quick-connect fresh gas outlet for easy and secure switching
between breathing circuits.
Copyright © 2015 Dispomed ltd
MODUFLEX NRB
In order to answer the needs of veterinarians working with very small animals, as well as research centers working with rodents or those who will only use an open circuit (Bain), Dispomed has developped the NRB.
SELECTATECTM
compatibility manifold foreasy and quick installationof vaporizer.
0.1 to 4 lpm flowmeter with rotary float and large scale for easy readability
Small “H” shaped stand occupies very little room as a portable table-top. Fits very easily inside the majority of laboratory ventilation hoods.
SELECTATECTM
compatibility manifold foreasy and quick installation
of vaporizer.
Up to 3 patients circuits
Copyright © 2015 Dispomed ltd
MODUFLEX LABVET
Non-rebreathing, research and lab animal applications. Specially designed for research and laboratory this is Dispomed’s most compact model.
MODUFLEX compared to VME and VMS
CaracteristicsModuflex Access 2
VMEModuflex Compact
VMSModuflex
EliteModuflex Coaxial
Moduflex Optimax
Moduflex Advantages
Flowmeter cartridge
Constructed of brass and
stainless steel making them much
sturdier.
Very easy to damage due to over tightening.
Constructed of brass,
plastic and stainless
steel making them much
sturdier.
Very easy to damage due to over tightening.
Constructed of brass and
stainless steel making them much
sturdier.
Constructed of brass and
stainless steel making them much
sturdier.
Constructed of brass and
stainless steel making them much
sturdier.
More resis-tant
Flowmeter Rotary float. Large scale.
BallRotary float. Large scale.
BallRotary float. Large scale.
Rotary float. Large scale.
Rotary float. Large scale.
Better visibil-ity. Easier to check flow accuracy.
Vaporizer mount
Cagemount Cagemount SelectatecTM Cagemount SelectatecTM SelectatecTM SelectatecTM
SelectatecTM mount is easier to install than cagemount and also a
wider choice of vaporizers.
Flush guard Yes No Yes No Yes Yes YesYou can’t
accidentally press it.
Sodalime canister
Absorber base with humidity
trap
The sodalime is channeled
through a U- shaped
canister and the most of the canister is filled with sodalime allowing no space for
condensation. As
condensation builds up,
the sodalime gets saturated
with water and increases
breathing resistance.
Absorber base with humidity
trap
Absorber base with
humidity trap. Water builds up directly in the sodalime
because there is no humidity trap. Increases
breathing resistance.
Absorber base with humidity
trap.
Absorber base with humidity
trap.
Absorber base with humidity
trap.
Reduced breathing resistance
compared to the VME.
Shelf OptionalOnly on the
VME + Optional
Standard on VMS + only
Standard Standard Standard
Useful to install monitors or anesthesia
accessories.
Fresh gas outlet
Quick connect Hose Barb Quick connect Hose barb Quick Connect Quick Connect Quick Connect
Quick connects are easier to connect
compared to regular hose barb and also
simpler to switch between
circuits.
Inclusions
Y Patient Circuit, 2 and 3 liter
bags, fresh gas hose, krytox
grease, evac-uation hose 5’, oxygen supply
hose.
None
Standard Circuit, 2 and 3 liter
bags, fresh gas hose, krytox
grease, evac-uation hose 5’, oxygen supply
hose.
None
Standard Circuit, 2 and 3 liter
bags, fresh gas hose, krytox
grease, evac-uation hose 5’, oxygen supply
hose.
Coaxial Circuit, 2 and 3 liter
bags, fresh gas hose, krytox
grease, evac-uation hose 5’, oxygen supply
hose.
Coaxial Circuit, 2 and 3 liter
bags, fresh gas hose, krytox
grease, evac-uation hose 5’, oxygen supply
hose.
These parts included at no
extra cost.
Warranty 5 years 3 years 5 years 3 years 5 years 5 years 5 years Longer warranty
SALES POINTS ON THE MODUFLEX LINE OF PRODUCTS
1. WARRANTY
• Five year warranty which means 2 years additional warranty on Moduflex machines (compared to Matrx). Covers all the plastic parts (not covered with Matrx warranty). Does not include the single use breathing circuits and bags.
2. VAPORIZER
• Selectatec vaporizer (Except on Access2) • Fast installation
3. REACTION TIME AND LOW RESISTANCE
• Quicker reaction time to bag the patient due to a special mechanism which keeps your bag inflated without any pressure.
• Momentary pop-off valve for an easy way to bag patient.
4. SODALIME CANISTER
• Flexible moulded plastic to prevent cracking.• Better use of the soda lime due to a better design. • Condensation base eliminates the moisture from the sodalime to avoid solidification and
reduce breathing resistance. • Bigger canister (1500cc compared to 1000cc) for better autonomy, less resistance at
inspiration. • Easy removal of sodalime canister for replenishing.
5. FLUSH VALVE
• Recessed flush valve to prevent accidental activation• Calibrated at 50 lpm for safer usage compared to most machines which are calibrated at 100
lpm• Reduce the risk of high pressure in the patient’s lungs
6. MOMENTARY POP-OFF VALVE (EXCEPT ON ACCESS2)
• Quicker to bag the patient• Prevent from forgetting to re-open
7. FLOWMETER
• Rotary float and large scale flowmeter • Easier readability (At the top of the float) • Easier to visualize a flow problem • Stainless steel flow control for durability
Copyright © 2015 Dispomed ltd
8. WHEELS
• 9 centimeter wheels for easy mobility of the unit (Coaxial, Elite and Optimax only).• 2 locking wheels on the front of the machine for more stability (Coaxial and Optimax only).• Easy dismantling of the wheels to clean them if blocked.
9. USER FRIENDLY
• Inspiration and exhalation domes are positioned so that you can easily keep an eye on them during procedures.
• Fresh gas connection on the front of the machine (Coaxial and Optimax only) allows a quick change from one circuit to another.
• Pressure gauge placed at a height easy to see for better readability.
Copyright © 2015 Dispomed ltd
NOTES
YEARS ANS
1982-2012
745 Nazaire-Laurin, Joliette (Qc) Canada J6E 0L6Tel: 1 (450) 759-9395 / Fax: 1 (450) [email protected] / www.dispomed.com