Versatile technology for safe and hazardous area applications Weighing Terminals IND560 industrial terminal Simple weighing or fully-integrated automatic process control; either way, the IND560 is the right solution for your application. Choose from strain gauge or high- precision electromagnetic force restoration weighing technologies. Specify direct PLC or PC communication interfaces. Utilize digital I/O control. Combine these selections in a panel mount enclosure that is certified for use in hazardous environments, and the IND560 is the perfect match for just about any weighing applica- tion, in a variety of industries. Comply with global regulations and standards. An IP69K rating makes the IND560 suitable for the harshest washdown conditions. Some models now certified safe for use in Divi- sion 2 or Zone 2/22 hazardous classified environments. Weigh with confidence. Ultrafast A/D (>366 Hz) and TraxDSP™ digital filtering combine to deliver precise, repeatable, reliable mea- surements from milligrams to tons. Control automatic material transfer applications without costly hardware and programming. An internal I/O option and built-in logic for filling and dosing provide process control without the need for a PLC. Connect to existing systems, easily. Multiple con- nectivity options are available. The IND560 supports Analog Output, Allen-Bradley RIO, DeviceNet, PROFIBUS, EtherNet/IP and Modbus TCP. Take advantage of serial or Ethernet TCP/IP connectivity to plug into your network.

Transcript of Versatile technology Terminals for safe and...

Page 1: Versatile technology Terminals for safe and …bradysystems.com/wp-content/uploads/2012/10/IND560-Data...Versatile technology for safe and hazardous area applications Weighing Terminals

Versatile technology for safe and hazardous area applications

Wei

ghin

g Te

rmin

als

IND560 industrial terminal

Simple weighing or fully-integrated automatic process control; either way, the IND560 is the right solution for your application. Choose from strain gauge or high-precision electromagnetic force restoration weighing technologies. Specify direct PLC or PC communication interfaces. Utilize digital I/O control. Combine these selections in a panel mount enclosure that is certified for use in hazardous environments, and the IND560 is the perfect match for just about any weighing applica-tion, in a variety of industries.

Complywith global regulations and standards. An IP69K rating makes the IND560 suitable for the harshest washdown conditions. Some models now certified safe for use in Divi-sion 2 or Zone 2/22 hazardous classified environments.

Weighwith confidence. Ultrafast A/D (>366 Hz) and TraxDSP™ digital filtering combine to deliver precise, repeatable, reliable mea-surements from milligrams to tons.

Controlautomatic material transfer applications without costly hardware and programming. An internal I/O option and built-in logic for filling and dosing provide process control without the need for a PLC.

Connectto existing systems, easily. Multiple con-nectivity options are available. The IND560 supports Analog Output, Allen-Bradley RIO, DeviceNet, PROFIBUS, EtherNet/IP and Modbus TCP. Take advantage of serial or Ethernet TCP/IP connectivity to plug into your network.

Page 2: Versatile technology Terminals for safe and …bradysystems.com/wp-content/uploads/2012/10/IND560-Data...Versatile technology for safe and hazardous area applications Weighing Terminals

IND560 Industrial Weighing TerminalWeighing solution for challenging industrial environments

Features and Benefits• Enclosurealternativesassureinstallationflexibility.Stainless

steel Harsh model, designed to minimize cleaning time, is ideal for heavy washdown using pressurized cleaning solutions. Stainless steel Panel mount with flush front panel reduces con-tamination

• Configureterminalthroughaneasytonavigate,menu-driven,"Windows-like" set-up

• 15programmablesoftkeysprovidedirectaccesstofunctions• Large,brightVFDdisplayiseasytoreadandreduceseyefatigue• UsetheIND560asaremotedisplayforotherMETTLERTOLEDO

products• Security:Supports20usernameswithuniquepasswordsprovid-

ing setup and metrology security on four levels• TraxDSP™:Tunabledigitalfilteringsupressesenvironmental

effects on weighing accuracy• MemoryTablesstoreupto25fixedtarerecords,eachwithaccu-

mulation, or 25 target records with tolerances• Forcheckweighingorfilling,selectOver/UndermodeorMaterial

Transfer mode to access built in logic for further customization of your application

• Comparatorsfeaturepermitsdefinitionoffivesimpletargetsusing multiple sources. Assignable digital outputs are available

• UseSmartTrac™tocustomizethedisplayofprocessinforma-tion. Multiple options control the amount of information shown on-screen.

• EnabletheRatefeaturetoshow'weightvs.time'dataontheter-minal display, or further use as a source for Comparators or the Analog Output

• Upto20programmableoperatorpromptsgiveon-screencom-mandsdirectingoperatorsthroughsequentialsteps,reducingopportunity for error. Messages can also be written to the termi-nal display from a remote location

• OptionalUSBQWERTYkeyboardinterfacepermitsfastandeasydata entry

• ApplicationModulespermittheadditionoffeatureswhereneeded. Select from Fill-560 for enhanced filling and dosing, Fill-Plus to store and resize formulas, Drive-560 for simple in and out vehicle transactions, COM-560 for communication with legacy protocols or for customized CTPZ type commands, and Dyn-560 for true in-motion package weighing

Page 3: Versatile technology Terminals for safe and …bradysystems.com/wp-content/uploads/2012/10/IND560-Data...Versatile technology for safe and hazardous area applications Weighing Terminals

www.mt.com/IND5xxFor more informationSubject to technical changes

©06/2012Mettler-Toledo,LLCINDB0004.12E

QualitycertificateISO9001EnvironmentcertificateISO14001Internet:http://www.mt.comWorldwide service

Enclosure dimensions (L x W x D) Panelmount:265x160x91.8mm(10.4x6.3x3.6in.)Harshmodel:265x160x170.3mm(10.4x6.3x6.7in.)

Enclosure construction Harshmodel:Stainlesssteel,IP69KcertifiedPanelmountmodel:Stainlesssteelfrontpanel,certifiedtype4x/12protection.Division2,Zone2/22approvalsrequireuseofsuitableenclosure

Shipping weight 3.5kg(7.7lbs)

Power Universalpowersupply,87to264VACat49to61Hz,600mAconsumption

Operating environment -10°C to +40°C(14°Fto104°F),10%to95%relativehumidity,non-condensing

Display Vacuumfluorescent,21mmweightdisplay,graphiccapabilities;128x64dotmatrix.Maximumresolution100,000divisions

Keypad Clear,Tare,Print,Zero,navigationkeyset,fullnumericalkeypad,5physicalsoftkeys(15totalassignments,alphanumericcapability

Supported scale types Analog:10VDCexcitation,powerupto8350Ωloadcells,2or3mV/VIDNet:Interfaceforcurrenthigh-precisionK-bases.OptionalpowersupplyforearlierK-basemodels. Warning! Division2,Zone2/22installationlimitationsexist;refertocontroldrawing72186884Rorcontactsupportforassistance

Calibration options Traditional calibration with separate zero and span captures, 5 step linearizationCalFree™electroniccalibration,requiresnotestweightsProgrammablecalibrationsequence(upto20steps)andconfigurablecalibrationexpirationalertsandactions

Connectivity Singleserialportstandard(COM1:RS-232/422/485);optional10Base-TEthernetTCP/IPportwithtwoadditionalserialports(COM2:RS-232;COM3:RS-232/422/485)oroptional10Base-TEthernetTCP/IPportwithUSBMasterandsingleserialCOM3(RS-232/422/485)oroptional10Base-T EthernetTCP/IPportwithUSBMasterandoneadditionalserialport(COM3:RS-232/422/485) Warning! Division2,Zone2/22installationlimitationsexist;refertocontroldrawing72186884Rorcontactsupportforassistance

Interface options PLC(selectoneoption):Allen-Bradley® Remote I/O, PROFIBUS®DP,DeviceNet™,AnalogOutput(4-20mAor0-10VDC),EtherNet/IP™,Modbus TCPLocalandRemoteI/O(relay-based):ARM100DigitalInput/OutputModule− Extends the discrete input and output control of the IND560 to remote locations,maximumof12inputsand18outputs.Warning!Relay-basedI/OoptionsarenotapprovedforinstallationinhazardousareasA100AnalogOutputModule:convertsMETTLERTOLEDOContinuousorSICSserialsignaltoa4/20mAsignal Warning! Division2,Zone2/22installationlimitationsexist;refertocontroldrawing72186884Rorcontactsupportforassistance

Agency Approvals Weights and Measures

USA ClassII100,000d,ClassIII/IIIL10,000d,CoC05-057A2

Canada ClassII100,000d,ClassIII10,000d,ClassIIIHD20,000d,AM-5593

Europe ClassIIdeterminedbyplatform,ClassIII10,000e,ClassIIII1000e.IncludesAlibiMemory,TC6812rev8MID −Catchweighing-T10230;Gravimetricfilling-T10231

Australia ClassIII7500eor3x3000emultiplerange,NMIS483

HazardousArea(wheninstalledperMETTLERTOLEDOcontroldrawing72186884R)

Panel,USA/Canada(UL):ClassIDivision2GPA-D;Class2Division2GPF,G:ClassIII;ClassI,Zone2GPIIC

Panel,Europe(ATEX):II3GEExnL[nL]IIBT4-10°C ≤ Ta ≤ +40°C.II3DT85°C-10°C ≤ Ta ≤ +40°C IP6X

Harsh,USA/Canada(UL):ClassIDivision2GPA-D;ClassIIDivision2GPF,G:ClassIII;ClassIZone2GPIIC

Harsh,Europe(ATEX*): II3GEExnL[nL]IIBT4-10°C ≤ Ta ≤ +40°C.II3DT85°C-10°C ≤ Ta ≤ +40°C IP69K* Harsh/IDNet model not included in Category 3 approvals

METTLERTOLEDOisuniquelyqualifiedtoprovidethe installation, calibration and maintenance services essential to ensuring accuracy, optimiz-inguptimeandprolongingequipmentlife.Ourservice representatives will be there at the right time, with the right parts, the right tools and the right skills to meet your needs.

Essential Services for Dependable Performance

IND560 TerminalTechnical Specifications