Venting & Inspection
![Page 2: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/2.jpg)
Differential Venting• Entry vent is at the end of the system
• Exit vent is on the roof of the building
• A minimum difference of 10’ is needed
• If a pumping station is used, install an air bypass pipe
![Page 3: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/3.jpg)
![Page 4: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/4.jpg)
EnviroSepticTM
Design Considerations /
Calculations
![Page 5: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/5.jpg)
Minimum # of Pipes = Peak Flow / 27.7 Imp. Gal (126 L)
Required Dispersal Area = Peak Flow / Infiltrative Loading Rate
Required System Sand = 12” (30cm) below AES Pipes
6” (15cm) on either side of AES Pipes
4” (10cm) above AES Pipes
Minimum Lateral Length = 20 Feet (2 Pipes)Maximum Lateral Length = 60 Feet (6 Pipes)
Treatment Capacity is the same regardless of whether it is front end
fed or Centre Fed; however, it is possible to Linear Load based on
the HLLR in Appendix A.1.E.1.
![Page 6: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/6.jpg)
EnviroSepticTM
System Configurations
![Page 7: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/7.jpg)
Trench System
![Page 8: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/8.jpg)
Subsurface Installation
![Page 9: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/9.jpg)
Above Ground
![Page 10: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/10.jpg)
Mound Installation
![Page 11: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/11.jpg)
Raised Sloping System
![Page 12: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/12.jpg)
Commercial System
![Page 13: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/13.jpg)
Low Pressure Distribution System –
Alternating Lateral Dosing
![Page 14: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/14.jpg)
Custom Configurations
![Page 15: Venting & Inspection€¦ · SEPTIC TANK 30 A-Center-to-center pipe spacing C-Minimum separation distance F.G.-Fina1 grade O.G.-Original grade W-Width of Enviro-Septic pipe SYSTEM](https://reader035.fdocuments.net/reader035/viewer/2022063010/5fc2138ccbb6bd7f7b42a8b1/html5/thumbnails/15.jpg)
Questions??