Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central...

22
Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K . Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for Scientific and Industrial Research(CSIR) Chandigarh ,India

Transcript of Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central...

Page 1: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K . Mahna

NIT KurukshetraCentral Scientific Instruments Organisation (CSIO)

Council for Scientific and Industrial Research(CSIR) Chandigarh ,India

Page 2: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

IntroductionObjectiveMaterials and MethodsObservationsResultsConclusionReferences

Page 3: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

GRF- Ground Reaction Force It is equal in magnitude and opposite in direction to the

force that the body exerts on the supporting surface through the foot .

Vertical GRF (Fz) & its importance- It is considered to be prominent amongst the three

components of the GRF and has importance in the gait analysis, clinical assessment etc.

Force Plate (FP)- To measure GRF in the human and animal locomotion.

Available FPs- AMTI FP, Bertec FP, Kistler FP Kistler FP- Standard Reference Tool Developed FP

Calibration Techniques Static calibration Dynamic Calibration

Page 4: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

To measure static & dynamic calibration of Developed FP

Comparison of their (kistler FP & Developed FP) results

Page 5: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

GRF MEASUREMENT WITH Kistler FP

Vertical component of ground reaction force

Subject walking on

force plate

Kistler Data Acquisition UnitPC with Analysis Software

Page 6: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

Type- 9286B (Switzerland)Sensing Devices- Piezoelectric

sensorsCost-17 lacksPlates- aluminum

Page 7: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

DAQ system for Bioware software

Type-5691A

Page 8: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

To measure & analyze the acquired signal

Force calculationMoment calculationCenter of pressure (COP) calculation

Page 9: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.
Page 10: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

Plates (2)-BrassSensors- Linear PotLength- 60 cmBreadth- 36 cmHeight- 7.4 cmSprings

arrangement

Page 11: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.
Page 12: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.
Page 13: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

NI USB-625932 inputs,16

bit,32Ms/sMultifunction

I/O with correlated digital I/O for USB

Page 14: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

LabVIEW –Laboratory Virtual Instrument Engineering Workbench

LabVIEW Signal Express-8.6

Major RoleSimulation Data AcquisitionInstrument ControlTesting & MeasurementsIndustrial automationData Analysis

Page 15: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

Calibration- calibration is a comparison between measurements-one of known magnitude or set with one device and another measurement made in a similar way as possible with a second device.

Purpose- to check if the developed FP gives the same measurement readings as the Kistler FP, thereby checking the repeatability, sensitivity, linearity of VGRF for the Developed FP.

Static Calibration: Input- Fixed Loads Output- Volts

Page 16: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

Dynamic CalibrationSubject- Human being Input- Applied Force from human feet during

walkingOutput- M-Shape curve in Volts

Page 17: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

Static Calibration Dynamic Calibration

Load Vs Voltage

Page 18: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

(N)

539 646 735

Page 19: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

Range of Weight ( Kg)

Sensitivity of Kistler FP (mv/N)

Sensitivity of Developed FP (mv/N)

55-66 12.22 41.11

66-75 6.667 28.88

Page 20: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

To evaluate Gait Parameters which are used for Prosthetic Knee quantification

In clinical assessments to know data analysis of a patient

Inexpensive

Page 21: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

[1]. Senanayake S.M.N.A .(2004) Walking, Running and Kicking using Body Mounted Sensors. Proceedings of the 2004 IEEE. Conference on Robotics, Automation and Mechatronics Singapore. Pg 1141-1146.

[2]. Hynd D.,Hughes S C.,Evins D J.( 2000) The development of a long, dual-platform triaxial walkway for the measurement of forces and temporal-spatial data in the clinical assessment of gait. Proc Instn Engrs vol 214 Part H: pg 193-201.

[3]. Liu T., Inoue Y., Shibata K.(2009) 3D Force Sensor Designed Using Pressure Sensitive Electric Conductive Rubber. Journal of system design and dynamics, VOL 3 No 3 pg 282-295.

[4]. Roland E.S., Hulla M.L., Stover S.M., (2005) Design and demonstration

of dynamometric horseshoe for measurinh ground reaction loads of horses during racing conditions. Journal of Biomechanics 38 : pg 2102-2112.

 

Page 22: Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.

THANK YOU!