24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE W415-1873 / 11.10.18 Specifications Front Options Framing Dimensions Model BTU Width Height Depth Viewing Area Actual Framing Actual Framing Actual Framing LV38N-1 30,000 53 5/16 53 13/16 41 3/16 73 19 7/8 20 1/8 40 3/4 X 18 5/8 LV38N2-1 30,000 53 5/16 53 13/16 41 3/16 73 16 3/16 16 3/16 40 3/4 X 18 5/8 single-sided Ref LV38-1 E 20 1/8” (51.1cm) F 53 13/16” (136.7cm) J Optional - Appliance does not need to be elevated above floor *L 73” (185.4cm) E J F minimum framing L note: The LV series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. note: Before framing the appliance, ensure to install the firestop first. see-thru Before framing the appliance, ensure to install the firestop first as it will not fit between the studs if installed after framing. * Minimum enclosure height maybe higher depending on venting configuration (see minimum distance to combustibles). Ref LV38-1 E 16 3/16” (41.1cm) F 53 13/16” (136.7cm) J Optional - Appliance does not need to be elevated above floor *L 73” (185.4cm) E F J minimum framing L note: The LV series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. note: Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information. 1 1 4 " MAX ADJUSTMENT 3 8 " 41 7 16 " 19 3 4 " SLF38K/SS PSB38SS/K 17 9 16 " 36 1 2 " 14 1 8 " 1 1 4 " MAX. ADJUSTMENT 1 NOTE 1" 39 7/8”

Transcript of VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE · 2020-04-04 · Fireplaces eating and Cooling --...

Page 1: VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE · 2020-04-04 · Fireplaces eating and Cooling -- Grills -8 napoleonproducts.com VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE W415-1873

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE

W415-1873 / 11.10.18

Specifications

Front Options

Framing Dimensions

Model BTUWidth Height Depth

Viewing AreaActual Framing Actual Framing Actual Framing

LV38N-1 30,000 53 5/16 53 13/16 41 3/16 73 19 7/8 20 1/8 40 3/4 X 18 5/8LV38N2-1 30,000 53 5/16 53 13/16 41 3/16 73 16 3/16 16 3/16 40 3/4 X 18 5/8

single-sided

Ref LV38-1

E 20 1/8” (51.1cm)

F 53 13/16” (136.7cm)

J Optional - Appliance does not need to be elevated above floor

*L 73” (185.4cm)

EJ

F

minimum framing

L

note:The LV series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles.

note:Before framing the appliance, ensure to install the firestop first.

see-thru

Before framing the appliance, ensure to install the firestop first as it will not fit between the studs if installed after framing.

* Minimum enclosure height maybe higher depending on venting configuration (see minimum distance to combustibles).

Ref LV38-1

E 16 3/16” (41.1cm)

F 53 13/16” (136.7cm)

J Optional - Appliance does not need to be elevated above floor

*L 73” (185.4cm)

E F

Jminimum framing

L

note:The LV series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles.

note:

Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information.

SLF38K/SS SLF50K/SS

1 14"

MAX ADJUSTMENT

1 14"

MAX ADJUSTMENT

38"

41 716

"

19 34

"

MIN. PROJECTION FROM FINISHING MATERIAL

38"

53 716

"

47 38

"19 34

"12 15

16"

SLF38K/SS PSB38SS/K

17 916 "

A

3612

"

14 18 "

1 14 "

MAX. ADJUSTMENT

1 NOTE

1"

NOTES:1 WHEN INSTALLED THIS SURFACE CAN BE FLUSH WITH THE FINISHING SURFACE SURROUNDING THE APPLIANCE (FINISHING

MATERIAL UP TO 1.75" THICK)

PSB___

KIT A

PSB38K/SS 39 7/8"

PSB50K/ SS 51 7/8"

PSB62SS 63 7/8"

PSB74SS 75 7/8"

A

B

C

D

1 2 3 4 5

A

B

C

D

1 5432

This drawing is the property of Wolf Steel LTD. or NAC. It is not to be reproduced nor used in any manner without our consent. All rights are reserved.

PREMIUM SAFETY BARRIER

39 7/8”

Page 2: VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE · 2020-04-04 · Fireplaces eating and Cooling -- Grills -8 napoleonproducts.com VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE W415-1873

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE

Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information.

Dimensions

Wall Penetration

Appliance LocationCombustible Mantel Clearances

LV38-1A

(Finishing Flange)40 3/4”

(1035mm)B 53 5/16”

(1354mm)C 57 5/16”

(1456mm)

*Finishing flange depth. (The finishing flange defines the perimeter of the fireplace opening. Framing or finishing materials must NEVER encroach inside the finishing flange.)

single-sided

LV38-1A

(Finishing Flange)40 3/4”

(1035mm)B 53 5/16”

(1354mm)C 57 5/16”

(1456mm)

see-thru

single-sided

The LV series requires a minimum enclosure height of 73” (185.4cm) measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles.

note:

Horizontal vent sections: A minimum clearance of 3” (76mm) on the top outside of the enclosure and 2” (51mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to combustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 6”(152mm) at the top of the vent pipe. Vertical vent sections: A minimum of 1” (25mm) all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliances enclo-sures. Vertical vent sections within enclosures require a minimum clearance of 1” (25mm) around the vent pipe.

see-thru

Horizontal vent sections: A minimum clearance of 3” (76mm) on the top outside of the enclosure and 2” (51mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to combustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 6”(152mm) at the top of the vent pipe. Vertical vent sections: A minimum of 1” (25mm) all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliances enclosures. Vertical vent sections within enclosures require a minimum clearance of 1” (25mm) around the vent pipe.

0

HEIGHT

MANTEL

MANTEL DEPTH1 2 3 4 5 6 7 8 9 1011

2468

1012141618202224

ED C B

A A

Top of finishing flange

Bottom of the appliance

25 11/16" (65.2cm)

2”

Bottom of finishing flange

Optional hearth extension (no

depth restriction)

MANTEL HEIGHT

MANTEL DEPTH

LV38-1*E 20 1/8” (51.1cm)F 53 13/16” (136.7cm)G 63 3/4” (162cm)H 18 3/16” (46.2cm)I 90 3/16” (229cm)

minimum framing

W415-1873 / 11.10.18

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

19 7/8"1/2”[12.7mm] 505mm

32 3/4"832mm

39 11/16"1008mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

A

B

C

SAFETY BARRIER

*

Base of air collar

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

32 3/4"832mm

39 11/16"1008mm

16 3/16"411mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

1/2"[12.7mm] 1/2"

[12.7mm]

A

B

C

SAFETY BARRIER

**

Base of air collar

Do not put objects in front of the appliance (minimum distance of 4 feet)

F

G

F

H

I

*E

1” (2.54cm) min.

6” (15.2cm) min.

*Single-sided model illustrated.

3” [76mm] top (outside of enclosure)

2” [51mm] sides / bottom (outside of enclosure)

0” to non-combustible finishing such as brick and stone

6” [152mm] minimum(inside enclosure)

0” to bottom of the appliance

0” to side standoffs

1/2” finishing flange

When passing through a ceiling, use firestop spacer W500-0028 (not supplied)

When passing through a wall, use firestop spacer W615-0162 (supplied with W010-4178 firestop spacer assembly)

0” to back standoffs

1” [25mm] minimum all sides for sections of vertical venting.

3” [76mm] (minimum all sides for sections of horizontal vent-ing) outside of enclosure.

73”minimum

The LV series requires a minimum enclosure height of 73” (185.4cm) measured from the bottom of the ap-pliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles.

note:

Shaded components (finish framing) must be non-combustible materials.

note:

SAFETY BARRIER

1/2” finishing flange (4 sides)

3” [76mm] top (out-side of enclosure)

2” [51mm] sides / bottom (outside of enclosure)

0” to non-combustible finish-ing such as brick and stone

6” [152mm] minimum(inside enclosure)

0” to side standoffs

0” to base of the appliance

When passing through a ceiling, use firestop spacer W500-0028 (not supplied)

When passing through a wall, use firestop spacer W615-0162 (sup-plied with W010-4178 firestop spacer assembly)

1” [25mm] minimum all sides for sections of vertical venting.

3” [76mm] (minimum all sides for sections of horizontal vent-ing) outside of enclosure.

14”(35.6cm)

min.

Shaded components (finish framing) must be non-combustible materials.

note:

73”minimum

*Finishing flange depth. (The finishing flange defines the perimeter of the fireplace opening. Framing or finishing materials must NEVER encroach inside the finishing flange.)

Page 3: VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE · 2020-04-04 · Fireplaces eating and Cooling -- Grills -8 napoleonproducts.com VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE W415-1873

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

SÉRIE VECTORMD 38 FOYER À GAZ D’ÉVACUATION DIRECTE

W415-1873 / 11.10.18

Spécifications

Façades Optionnelle

Dimensions d’ossature

Modèle BTULargeur Hauteur Largeur

Dimensions de VisioneRéel Ossature Réel Ossature Réel Ossature

LV38N-1 30,000 53 5/16 53 13/16 41 3/16 73 19 7/8 20 1/8 40 3/4 X 18 5/8LV38N2-1 30,000 53 5/16 53 13/16 41 3/16 73 16 3/16 16 3/16 40 3/4 X 18 5/8

Ref LV38-1

E 20 1/8” (51.1cm)

F 53 13/16” (136.7cm)

J Optionnel - l’appareil ne doit pas être élevé au-dessus du plancher

*L 73” (185.4cm)

EJ

F

ossature minimum

L

note:La série LV requis un minimum hau-teur de l’enceinte de 73” mesuré du bas de l’appareil. Pour les exigences de températures, cet espace doit être dégager. Certains configurations requis une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles.

note:Avant d’encadrer l’appareil, assurez-vous d’installer l’espaceur coupe-feu.

Avant d’encadrer l’appareil, assurez-vous d’installer l’espaceur coupe-feu premier avant qu’il ne soit pas adapté entre les goujouns après l’encadrement.

* L’hauteur minimum de l’enceinte peut être plus grand dépendant du configuration d’évacuation (voir distance minimum aux matériaux combustibles).

Ref LV38-1

E 16 3/16” (41.1cm)

F 53 13/16” (136.7cm)

J Optionnel - l’appareil ne doit pas être élevé au-dessus du plancher

*L 73” (185.4cm)

E F

Jossature minimum

L

note:La série LV requis un minimum hau-teur de l’enceinte de 73” mesuré du bas de l’appareil. Pour les exigences de températures, cet espace doit être dégager. Certains configurations requis une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles.

note:

Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour info-formation d’installation actuel.

SLF38K/SS SLF50K/SS

1 14"

MAX ADJUSTMENT

1 14"

MAX ADJUSTMENT

38"

41 716

"

19 34

"

MIN. PROJECTION FROM FINISHING MATERIAL

38"

53 716

"

47 38

"19 34

"12 15

16"

SLF38K/SS PSB38SS/K

17 916 "

A

3612

"

14 18 "

1 14 "

MAX. ADJUSTMENT

1 NOTE

1"

NOTES:1 WHEN INSTALLED THIS SURFACE CAN BE FLUSH WITH THE FINISHING SURFACE SURROUNDING THE APPLIANCE (FINISHING

MATERIAL UP TO 1.75" THICK)

PSB___

KIT A

PSB38K/SS 39 7/8"

PSB50K/ SS 51 7/8"

PSB62SS 63 7/8"

PSB74SS 75 7/8"

A

B

C

D

1 2 3 4 5

A

B

C

D

1 5432

This drawing is the property of Wolf Steel LTD. or NAC. It is not to be reproduced nor used in any manner without our consent. All rights are reserved.

PREMIUM SAFETY BARRIER

39 7/8”

un seul côté voir à travers

Page 4: VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE · 2020-04-04 · Fireplaces eating and Cooling -- Grills -8 napoleonproducts.com VECTOR™ 38 DIRECT VENT LINEAR GAS APPLIANCE W415-1873

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

SÉRIE VECTORMD 38 FOYER À GAZ D’ÉVACUATION DIRECTE

Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour info-formation d’installation actuel.

Dimensions

Passage d’un section dans un mur

Location de l’appareilDégagements Combustible de la Tablette

LV38-1A

(Bride de finition)40 3/4”

(1035mm)B 53 5/16”

(1354mm)C 57 5/16”

(1456mm)

* La profondeur de la bride de finition (la bride de finition définit le périmètre de l’ouverture de la cheminée. Les matériaux de charpente ou de finition NE JAMAIS empiété à l’intérieur de la bride de finition.

LV38-1A

(Bride de finition)40 3/4”

(1035mm)B 53 5/16”

(1354mm)C 57 5/16”

(1456mm)

La série LV nécessite une hauteur minimale de 73” (185,4cm) mesurée par le bas de l’appareil. Pour les exigences de températures, l’espace doit être laisser sans obstruction. Certains configurations qui requis une course verticale plus large aura besoin d’une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles.

note:

Sections d’évents horizontales: Un dégagement minimum aux matériaux combustibles de 3” (76mm) au-dessus hors de l’enceinte et 2” (51mm) sur les côtés et au-dessous hors de l’enceinte toute autour du conduit d’évacuation sur toutes les courses horizontales. Les sections d’évacuation horizontales dans les enceintes doit maintenir un dégagement minimaux de 6” (152mm) au-dessus du conduit d’évacuation. Sections d’évents verticales: Un dégagement minimum aux matériaux combustibles de 1” (25mm) est requis toute autour du conduit d’évacuation sur toutes les courses verticales à l’exception des dégagements à l’intérier de l’enceinte de l’appareil. Les courses d’évacuation verticales dans les enceintes requis un dégagement minimum de 1” (25mm) autour du conduit d’évacuation.

Sections d’évents horizontales: Un dégagement minimum aux matériaux combustibles de 3” (76mm) au-dessus hors de l’enceinte et 2” (51mm) sur les côtés et au-dessous hors de l’enceinte toute autour du conduit d’évacuation sur toutes les courses horizontales. Les sections d’évacuation horizontales dans les enceintes doit maintenir un dégagement minimaux de 6” (152mm) au-dessus du conduit d’évacuation. Sections d’évents verticales: Un dégagement minimum aux matériaux combustibles de 1” (25mm) est requis toute autour du conduit d’évacuation sur toutes les courses verticales à l’exception des dégagements à l’intérier de l’enceinte de l’appareil. Les courses d’évacuation verticales dans les enceintes requis un dégagement minimum de 1” (25mm) autour du conduit d’évacuation.

0

HEIGHT

MANTEL

MANTEL DEPTH1 2 3 4 5 6 7 8 9 1011

2468

1012141618202224

ED C B

A A

Top of finishing flange

Bottom of the appliance

25 11/16" (65.2cm)

2”

Bottom of finishing flange

Base de protec-tion optionnelle

MANTEL HEIGHT

MANTEL DEPTH

LV38-1*E 20 1/8” (51.1cm)F 53 13/16” (136.7cm)G 63 3/4” (162cm)H 18 3/16” (46.2cm)I 90 3/16” (229cm)

ossature minimum

W415-1873 / 11.10.18

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

19 7/8"1/2”[12.7mm] 505mm

32 3/4"832mm

39 11/16"1008mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

A

B

C

Barrière de protection

*

Base du collet d’air

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

32 3/4"832mm

39 11/16"1008mm

16 3/16"411mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

1/2"[12.7mm] 1/2"

[12.7mm]

A

B

C

Barrière de protection

**

Base du collet d’air

Do not put objects in front of the appliance (minimum distance of 4 feet)

F

G

F

H

I

*E

1” (2.54cm) min.

6” (15.2cm) min.

*Modèle d’un seul côté illustré.

6” [152mm] minimum(dedans l’enceinte)

0” vers le bas de l’appareil

0” aux contraintes latérales

1/2” bride de finition

0” aux contraintes arrière

3” [76mm] (minimum toutes les côtés pour les sections d’évacuation horizontales) hors de l’enceinte.

73”minimum

La série LV nécessite une hauteur minimale de 73” (185,4cm) mesurée par le bas de l’appareil. Pour les exigences de températures, l’espace doit être laisser sans obstruction. Certains configurations qui requis une course verticale plus large aura besoin d’une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles.

note:

Les composants ombragés (encadre-ment de finition) doivent être de matériaux incombustibles.

note:

Barrière de protection1/2” bride de finition

3” [76mm] haut (hors de l’enceinte)

2” [51mm] côtés / bas (hors de l’enceinte)

0” aux finitions incom-bustibles telles que le brique et la pierre

6” [152mm] minimum(dedans l’enceinte)

0” aux contraintes latérales

0” vers le bas de l’appareil

Lorsque vous passez par un mur, utilisez l’espaceur coupe-feu W615-0162 (fourni avec l’assemblage d’espaceur coupe-feu W010-4178

3” [76mm] (minimum toutes les cô-tés pour les sections d’évacuation horizontales) hors de l’enceinte.

14”(35.6cm)

min.

Les composants ombragés (encadre-ment de finition) doivent être de matériaux incombustibles.

note:

73”minimum

un seul côté voir à travers

un seul côté voir à travers

En passant par un pla-fond, utilisez l’espaceur coupe-feu W500-0028 (non fourni)

1” [25mm] minimum tous les côtés pour les sections d’évacuation verticale.

3” [76mm] haut (hors de l’enceinte)

2” [51mm] côtés / bas (hors de l’enceinte)

0” aux finitions incom-bustibles telles que le brique et la pierreLorsque vous passez par un mur, utilisez l’espaceur coupe-feu W615-0162 (fourni avec l’assemblage d’espaceur coupe-feu W010-4178

En passant par un plafond, uti-lisez l’espaceur coupe-feu W500-0028 (non fourni)

1” [25mm] minimum tous les côtés pour les sections d’évacuation verticale.

Ne placez pas d’objets devant l’appareil (distance minimale de 4 pi.)

MANTEL HEIGHT

MANTEL DEPTH

Hauteur de tablette

Profondeur de tablette

Hauteur de tablette

Profondeur de tablette

* La profondeur de la bride de finition (la bride de finition définit le périmètre de l’ouverture de la cheminée. Les matériaux de charpente ou de finition NE JAMAIS empiété à l’intérieur de la bride de finition.