1 IntroductionVEA-501/401 Gas Analyzer is for measuringCO, HC and CO2 in automotive emissions bythe principle of non-dividing infraredabsorption, measuring NONot for VEA-401
and O2 by the principle of electrochemical cell,
calculating excessive air coefficient based
on the composition of CO, CO2, HC and O2measured. This instrument is equipped withgas bench with self-owned intellectualproperty right, microprocessor is embedded. Itis an intellectual instrument with liquid crystaldisplay and Chinese or English interface.Inductive RPM (engine-speed) measuringpliers, oil temperature sensor and printer areoptional for measuring RPM and oiltemperature, and printing measurementresults.
This instrument complies with therequirements of International MeasurementRules OIML R99/1998 (E) made by theOrganization of International MeasurementLaw (OIML) and the National MetrologicalVerification Regulations # JJG 688 for class-1instruments. It is applicable for environmentaldepartments, vehicle inspection stations,automotive manufacturing factories andgarages.
2 Technical Specification
Operation Condition
Temperature +5 to +40Relative humidity 5 to 95non-condensing
Atmospheric pressure 70 kPa to 106 kPa
Power supply
Voltage AC110V15
Frequency 60Hz 1Hz
Measurement Range
HC (Hexane
Equivalent)
0ppm to 10000ppm
PDF created with pdfFactory Pro trial version www.pdffactory.com
http://www.pdffactory.com/http://www.pdffactory.com/ -
8/8/2019 VEA 501 Gas Analyzer
2/3
CO 0% to 10%
CO2 0% to 20%
O2 0% to 25%
NO (Not for NHA-406) 0ppm to 5000ppm
RPM 300rpm to 8000rpm
Oil Temperature 0 to +120
Resolution
HC 1ppm
CO 0.01%
CO2 0.01%
O2 0.01%
NO (Not for NHA-406) 1ppm
RPM 10rpm
Oil Temperature 1
Indication Error Absolute Relative
0ppm to 2000ppm 12ppm 5%
HC2001ppm to 10000ppm - 10%
CO 0.06% 5%
CO2 0.5% 5%
O2 0.1% 5%
NO (Not for NHA-406) 25ppm 4%
Others
Warm-up Time 10 minutes
Output Interface RS-232C
Outer Dimension (L)450mm(W)260mm(H)180
mm
Net Weight 7kg
3 Description of the Unit
Composition
As shown in Fig. 3-1 the instrument is
composed of the instrument host, short tube,pre-filter, sampling pipe, sampling probe andembedded micro printer (optional).
Fig. 3-1 Composition of the Unit1Instrument host control measurement
and analyze emissions components
2Embedded micro printer (optional)
3Sampling pipe (5m)connect pre-filter
and sample gas inlet
4Pre-filter: pre-filter sample gases
5Short tube connect pre-filter and
sampling probe
6Sampling probe sample vehicle
emissions.
3.2 Front Panel
Fig. 3-2 shows the layout of the front panel.Names and functions of all the parts on frontpanel:
1
2
3
4
5
Fig. 3-2 Layout of Front Panel
1Liquid crystal display: display menus andmeasurement data
2S keycorresponding to the functional
sub-menu at the lower part of LCD, executethe corresponding operation
3K keycorresponding to the functional
sub-menu at the lower part of LCD, executethe corresponding operation
4 keymove the cursor on LCD
upward and select the required item
corresponding to the functional sub-menu atthe lower part of LCD, execute the
corresponding operation5 keymove the cursor on LCD
downward and select the required item
corresponding to the functional sub-menu atthe lower part of LCD, execute thecorresponding operation.
3.3 Rear Panel
Fig. 3-3 shows the layout of the rear panel.Names and functions of all the parts on rearpanel:
Power
Communication/Printing
Gas Outlet
Calibration Gas Inlet
Zero Gas Filter
RS-232C
2 43 51 6
PDF created with pdfFactory Pro trial version www.pdffactory.com
http://www.pdffactory.com/http://www.pdffactory.com/ -
8/8/2019 VEA 501 Gas Analyzer
3/3
Fig. 3-3 Layout of Rear Panel
1Oil temperature signal socket: inputsignal of oil temperature sensor
2Mains socket and switch: the socket is for220V AC power input, and the switch is forpower on / off, with built-in 1A fuse and filter for
mains noise
3RS-232C socketfor communication withexternal computer
4COM/Printing Selectorswitch between
Printing and COM.
5Gas outletmain outlet for sample gas
after measurement
6Condenser and sample gas inletconnect
outlet of pre-filter via short tube, to introducesample gas. Condenser can lower sample gastemperature to prevent condensation insampling system
7RPM signal socket: input signal of RPM
measuring pliers or RPM adaptor
8Outletof NO sensor
9Sensor cap: for protection of NO sensorand O2 sensor;10Outlet of O2 sensor
11Zero gas filterfilter the dust in air
12Calibration gas inlet: used as inlet ofstandard gas, with pressure of approx.0.02 MPa
13Water filter: separate oil, dust and waterin sample gas, replace the internal big / small
filter elements as required.
Warranty
THIS WARRANTY IS EXPRESSLY LIMITED TOPERSONS WHO PURCHASE LAUNCH PRODUCTSFOR PURPOSES OF RESALE OR USE IN THEORDINARY COURSE OF THE BUYERSBUSINESS.LAUNCH electronic product is warranted againstdefects in materials and workmanship for one year(12 months) from date of delivery to the user. This
warranty does not cover any part that has beenabused, altered, used for a purpose other than forwhich it was intended, or used in a mannerinconsistent with instructions regarding use. Theexclusive remedy for any automotive meter found tobe defective is repair or replacement, and LAUNCHshall not be liable for any consequential or incidentaldamages. Final determination of defects shall bemade by LAUNCH in accordance with proceduresestablished by LAUNCH. No agent, employee, orrepresentative of LAUNCH has any authority to bind
LAUNCH to any affirmation, representation, orwarranty concerning LAUNCH automotive meters,except as stated herein.
Disclaimer
THE ABOVE WARRANTY IS IN LIEU OF ANYOTHER WARRANTY, EXPRESSED OR IMPLIED,INCLUDING ANY WARRANTY OFMERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE.
Order Information
Replaceable and optional parts can be ordereddirectly from your LAUNCH authorized tool supplier.Your order should include the following information:
1. Quantity2. Part number3. Item description
Customer Service
If you have any questions on the operation of the unit,please contact us:
Tel: 00971-4-8832299Fax: 00971-4-8832232,E-mail: [email protected]
PDF created with pdfFactory Pro trial version www.pdffactory.com
http://www.pdffactory.com/http://www.pdffactory.com/mailto:[email protected]:[email protected]