Varian Days 2010 490-GC Portable

58
490-GC: The “Go Anywhere” Micro-GC

description

This is a short presentation on the main features of the Varian (now Agilent) portable GC — the best of its kind!

Transcript of Varian Days 2010 490-GC Portable

Page 1: Varian Days 2010 490-GC Portable

490-GC: The “Go Anywhere” Micro-GC

Page 2: Varian Days 2010 490-GC Portable

2

What is the 490-GC

• The 490-GC is Varian’s 5th generation of the Micro-GC series

• Small, fast and rugged gas analyser

• Based on advanced micro-machining technology

• Instrument control and data handling by Galaxie

• Usage in laboratory, on-line, at-line and for field applications

Page 3: Varian Days 2010 490-GC Portable

3

Why the 490-GC

• Immediate answers for gas and vapour samples• Fast analysis, separations in seconds• Analyse anywhere, in the lab, at-line, on-line, in the field• Easy to use, no need for specialised trained personnel• Consuming less bench space• Local or remote control• Complete software and user-programs• Savings on gas cylinder purchases and gas related

items• Savings on installation time

Page 4: Varian Days 2010 490-GC Portable

4

What is a 490-GC

The 490-GC is• Multi Method• Multi Stream

–Micro GC- Controlled by and reporting by Galaxie data

handling package- High Speed Gas analysis

Page 5: Varian Days 2010 490-GC Portable

5

490-GC Dual and Quad version

490-GC Dual cabinet 490-GC Quad cabinet

Page 6: Varian Days 2010 490-GC Portable

6

How does the 490-GC Micro-GC Work

Page 7: Varian Days 2010 490-GC Portable

7

490-GC Micro-Machined Technology

CHIPINJECTOR

GCCOLUMN MICRO TCDMICRO EGC

Page 8: Varian Days 2010 490-GC Portable

8

How does the 490-GC Micro-GC Work

Complete miniaturised GC system:• 1 up to 4 complete GC channels

Each GC channel is a separate GC:• Silicon micro-machined injector• Oven with analytical column • Micro-machined Thermal Conductivity Detector (µ-TCD)• Pneumatics• Electronics

Each channel is tuned for a specific part of the sample

Page 9: Varian Days 2010 490-GC Portable

9

Permanent Gases

Peak identification1 Hydrogen2 Oxygen3 Nitrogen4 Methane5 Carbon Monoxide

CP-Molsieve 5Å Temperature : 80°CCarrier gas : Argon

Page 10: Varian Days 2010 490-GC Portable

10

Light Hydrocarbons

Peak identification1 Carbon Dioxide2 Ethylene3 Ethane4 Acetylene5 Hydrogen Sulfide

CP-Pora PLOT-U Temperature : 90°CCarrier gas : Helium

Page 11: Varian Days 2010 490-GC Portable

11

Extended Hydrocarbons

Peak identification1. iso-Pentane2. normal-Pentane3. Hexane4. iso-Octane

CP-Sil 5 CBTemperature : 80°CCarrier gas : Helium

Page 12: Varian Days 2010 490-GC Portable

12

490-GC Communication

Various communication protocols

• Standard Ethernet TCP/IP

• Six analogue input signals(external process signals)

• Optional two extra Com Ports for external devices

• Selectable RS-232 or RS-485

Page 13: Varian Days 2010 490-GC Portable

13

490-GC

Galaxie Data System

IntegrationCalculation

Control

Signal

Report

• Instrument Control• Data Acquisition• Report Generation

Galaxie™ Chromatography Software

Page 14: Varian Days 2010 490-GC Portable

14

490-GC PRO VersionA Fast, Small Form Factor, High

Performance Gas Measurement Platform Designed for Unattended Operation and

supports Industrial networks

Page 15: Varian Days 2010 490-GC Portable

15

490-GCPC Data System

Control

Signal

Set up / Operation

Report

490-GC Standard versus 490-GC PRO

PCPROstation 490-GC PRO

Maintenance

490-GC PROPC PROstation

CommunicationResult Industrial

networks

Page 16: Varian Days 2010 490-GC Portable

16

490-GC PRO Objective

Product differentiation• Process Environment• On-line / at-line

Benefits• Implement proven Lab Technology

in Process Analytics • Instrument-hardware availability for autonomous

operation• Communicates results instead of raw/signal data

Page 17: Varian Days 2010 490-GC Portable

17

What is a 490-GC PRO

The 490-GC PRO isSingle Method

AutonomousMulti Sample Stream

High Speed Gas analysisAnalyser / Monitor (Micro-GC)

Communicator of Results

Page 18: Varian Days 2010 490-GC Portable

18

490-GC PRO

OBDH

Local display(optional)

Automation

Application

External I/Odevices

Modbus

FTP client

PROstation

Page 19: Varian Days 2010 490-GC Portable

19

On Board Data Handling

Built into the 490-PRO:• Peak integration• Peak identification• Peak calibration• Peak grouping

This means that for routine measurements:• Full autonomous operation (no operator required)• No external data handling software required • No PC needed to generate results

Page 20: Varian Days 2010 490-GC Portable

20

490-PRO – Fully Automated Operation

Sequential measurement runs that include:• sample type • valve/sample position• flush time• calibration level

Calibration and/or verification analysis• after a desired # of samples • based on a specific time• on demand via remote command• automatic (re)calibration if verification values “fail”

Page 21: Varian Days 2010 490-GC Portable

21

490-PRO – Fully Automated Operation

Stream selection and control:• Electrically actuated multi-position valves • Solenoids based stream selectors

Remote Communication:• MODBUS • Digital input

Page 22: Varian Days 2010 490-GC Portable

22

Standard Functionality

• Validation of• Verification samples• Sample streams• Calibration samples

• Calculation parameters:• Multi channel normalisation. Optional a bridge component• Add estimated concentrations for non detected peaks• Convert acquired analog input signals to functional values, ex.

sample flow• Definable alarms to:

– activate a relay – store results in MODBUS registers

• Definable 4-20 mA signals

Page 23: Varian Days 2010 490-GC Portable

23

Additional available Functionality in 490-PRO

“Energy meter”• According to ISO 6976, ASTM D3588, GPA 2172 and GOST

– calorific value– relative density – compressibility factor

35 day logging:• according API (chapter21)

Serial output:• MODBUS communication

Note: requires licenses

Page 24: Varian Days 2010 490-GC Portable

24

MODBUS (490-PRO is a MODBUS “slave”):

Communication:• Serial: RS-232 or RS-485• Ethernet TCP/IP

Commands from Industrial Network:• Start analysis type

– Run, calibration, verification, column conditioning, method parameters

• Stream selectionInformation to Industrial Network:

• Instrument status • OBDH results• Application results

Highly Flexible Communication & I/O

RS-232 or RS-485

Ethernet TCP/IP

Page 25: Varian Days 2010 490-GC Portable

25

490-GC PRO Connectivity

Page 26: Varian Days 2010 490-GC Portable

26

490-GC PRO Customer Responsibilities

Sample inlet tubing and

Sample conditioning

I/O Cable Connections

Display Fitting/MountingDCS Connections

&Programming

Page 27: Varian Days 2010 490-GC Portable

27

PRO Station Software

OBDH settings• Integration• Identification• Calibration settings

“Automation” settings • sequence• verification • calibration

Instrument method setup • temperatures, • pressures, etc.

PRO Station

TCP/IP

Page 28: Varian Days 2010 490-GC Portable

28

Application method setup• alarms• validations• external I/Os• calorific constants• sample conditions, etc)• LCD display parameters

Displayed• Chromatogram• Integration parameters• Instrument Status• Results (obtained from OBDH of 490-PRO)• MODBUS register table setup

PRO Station Software

Page 29: Varian Days 2010 490-GC Portable

29

Sample / Application results can be communicated via

• ModBus (incl instrument status) via TCP/IPoptional via RS232

• Analog output 4-20mA, extension board• Digital I/O, alarms, extension board

• Text file FTP/Client Server, via TCP/IP• LCD display (incl instrument status), serial port

• Web browser (incl instrument status), TCP/IP

Information is available to the outside world in different formats

Results !!! Not chromatograms and reports

Output of Results

Page 30: Varian Days 2010 490-GC Portable

30

Software Options

• 35 Day Logging (API Chapter 21):– Analysis data – Averages, Minimums and maximums of analysis data – Calibration data – Alarms – Method parameter changes – Power On-Off events – Error chromatograms (one per stream) – Static data (ID calibration cylinder, site name, etc.)

• Includes “history log” (remote PC)• Standard HTML reports• Custom HTML reports

Page 31: Varian Days 2010 490-GC Portable

31

19” Rack mounting

• Dual channel Micro-GC• Options

– Stream selection valve– Micro-Gasifier– Extension boards– Genie membrane filter– LCD screen– Pressure sensors

Page 32: Varian Days 2010 490-GC Portable

32

Sample Stream Automation

• Multiple sample stream measurement is possible• Stream selection:

– Valco electrically actuated multi positional valve – serially connected to the 490-GC– Simultaneously control 3 X16 ports; 46 streams max

• Solenoid based stream selectors: – Via relay control

• Similar to the standard 490-GC

RS-232

Page 33: Varian Days 2010 490-GC Portable

33

User definable • Time based scrolling• Sample results• GC status• Error information

External device • up to 10 meter from instrument• user can choose where to mount it

Communication• RS-232

RS-232

LCD Display

Page 34: Varian Days 2010 490-GC Portable

34

External Hardware Options

Extension boards:• Stackable up to 8 boards with

• maximum 64 relays• maximum 25 analog outputs

– 4-20mA outputs, 0-1V• maximum 64 digital I/O

• mountable on DIN-rail

• This means:• Flexible and robust connections• Standardised connections

Basic board on DIN rail housing

Analog board

Digital board

Page 35: Varian Days 2010 490-GC Portable

35

WebServer

• Inside 490-PRO• Obtain status from anywhere

490-PRO System

Page 36: Varian Days 2010 490-GC Portable

36

Application overview

Page 37: Varian Days 2010 490-GC Portable

490-GC & 490-GC PRO Options

Page 38: Varian Days 2010 490-GC Portable

38

RTS (Retention Time Stability), option

• Molsieve Columns• Increased retention time due to moisture/CO2

• Al2O3 Columns• Retention time shift due to moisture

Solution• Molsieve trap integrated

• Remove Moisture and CO2

– Improved backflush for % level CO2

Page 39: Varian Days 2010 490-GC Portable

39

Achieving stable retention times.

Retention time decreases steadily

Almost immediate stable retention times

Page 40: Varian Days 2010 490-GC Portable

40

Permanent Gases in Natural Gas

Column: Hayesep, 0.4m

Temperature: 60°C

Carrier Gas: Helium, 140 kPa

Page 41: Varian Days 2010 490-GC Portable

41

Hydrocarbons in Natural Gas

Column: CP-Sil 5 CB, 4m

Temperature: 60°C

Carrier Gas: Helium, 135 kPa

Page 42: Varian Days 2010 490-GC Portable

42

Extended Hydrocarbon Analysis

Column: CP-Sil 5 CB, 8m

Temperature: 140°C

Carrier gas: 150 kPa, Helium

Page 43: Varian Days 2010 490-GC Portable

43

THT in natural gas

Column: CP-Sil 19 CB, 6m

Temperature: 90°C

Carrier Gas: Helium, 150 kPa

Page 44: Varian Days 2010 490-GC Portable

44

Permanent gases on CP-COX column

Page 45: Varian Days 2010 490-GC Portable

45

Biogas, composition (1)

Page 46: Varian Days 2010 490-GC Portable

46

Biogas Application

Composition primarily CH4, CO2, N2 and some H2, O2and CO

• Channel 1. Molsieve column– H2, O2, N2, CH4 and CO

• Channel 2. PoraPLOT U column– CO2 and H2S

Page 47: Varian Days 2010 490-GC Portable

47

Biogas, channel 1, permanent gases

Molsieve column, 80°C

Carrier gas: Ar, 150 kPa

Backflush of C2+, CO2, moisture

Page 48: Varian Days 2010 490-GC Portable

48

Biogas, Channel 2, C2, C3, H2S and CO2,

PoraPLOT U column, 100°C

Carrier gas: He, 100 kPa

Back flush of C4+

Page 49: Varian Days 2010 490-GC Portable

49

Biogas, Channel 3, C3+

CP-Sil 5 CB column, 60°C

Carrier gas: He, 150 kPa

Page 50: Varian Days 2010 490-GC Portable

50

Accessories

• Gasifier• Genie filter• Stream Selection Valve• Field case• 19” Rack Housing• Syringe Injection• Integrated sample conditioning

Page 51: Varian Days 2010 490-GC Portable

51

Micro-Gasifier Mounted on 490-GC

Power Supply

Vent Outlet

Sample In

Sample Flow Control

Vent Flow Control

Conditioned Transfer Line

Page 52: Varian Days 2010 490-GC Portable

52

Genie Membrane Filter

• Protects the analyzer from damage and contamination

• Fully inert membrane technology

• Proven and widely accepted filtering technique

• Removes liquids from gas samples

• Removes particles from gas samples

• No interference with sample composition

• Compliant for BTU calorific value applications

• Suitable for PPB, PPM and percentage level analysis

• Standard Swagelok™ connections

• High and low flow membranes

• Stainless Steel, Polypropylene and Kynar housing

• Standard Viton housing seal

• Easy connection with 490-GC

Genie Model 170

Page 53: Varian Days 2010 490-GC Portable

53

490-GC Dual and Quad Field Cases

490-GC dual field case

490-GC quad field case

Page 54: Varian Days 2010 490-GC Portable

54

490-GC Field case

A

E

C

B

D

C

B

E

D

F

A

A. canister pressure gauge

B. battery indicator

C. fill opening for canister

D. open/close valve canister

E. handle for easy slide out of

dock station

F. battery compartment

Page 55: Varian Days 2010 490-GC Portable

55

19” Rack Micro-GC

Page 56: Varian Days 2010 490-GC Portable

56

New Syringe Injection

Page 57: Varian Days 2010 490-GC Portable

57

Syringe Injection

• Unheated• Front inlet• Septum nut

• 1/8” sample inlet still available• Luer Lock

• Standard 1/16” inlet still available• Optional way Ball valve

• Sample selectable via Syringe option or standard inlet

Page 58: Varian Days 2010 490-GC Portable

58