U/UC SERIES - Alpine Home Air

4
SS-208D 12/03 PRODUCT SPECIFICATIONS www.goodmanmfg.com Cased & Uncased Upflow & Downflow Evaporator Coils The cased and uncased upflow and downflow evaporator coils are made for split system air conditioners and heat pumps and may be installed in a closet, utility room or basement. Standard Features • Compact, versatile, upflow or downflow position • Copper tube aluminum fin coil • Fully insulated cabinet on cased coils • Equipped with a check flowrator for heat pump and cooling unit operation • No rust high temperature thermoplastic drain pans for upflow and downflow application with secondary drain U/UC SERIES Cabinet Construction • Insulated steel cabinet • No rust galvanized stucco finish Accessories • Downflow kits (DFK or DFKT) used for all multi-position furnaces for downflow applications 1 to 5 Ton

Transcript of U/UC SERIES - Alpine Home Air

SS-208D 12/03

PRODUCT SPECIFICATIONS

www.goodmanmfg.com

Cased & UncasedUpflow & Downflow

Evaporator Coils

The cased and uncased upflow and downflow evaporator coils are made for

split system air conditioners and heat pumps and may be installed in a closet,

utility room or basement.

Standard Features• Compact, versatile, upflow or downflow

position• Copper tube aluminum fin coil• Fully insulated cabinet on cased coils• Equipped with a check flowrator for heat pump

and cooling unit operation• No rust high temperature thermoplastic drain

pans for upflow and downflow application with secondary drain

U/UC SERIES

Cabinet Construction• Insulated steel cabinet• No rust galvanized stucco finish

Accessories• Downflow kits (DFK or DFKT) used for all

multi-position furnaces for downflow applications

11⁄2 to 5 Ton

PRODUCT SPECIFICATIONS

2 3

PRODUCT SPECIFICATIONS

Uncased Upflow Evaporator Coils

Model

Dimensions Specifications

A B C NominalTons

NominalCFM

StaticPressureWet Coil

No.Rows

LiquidConn.

SuctionConn.

ShipWeight

(pounds)UC-18 13” 141⁄4” 201⁄8” 11⁄2 650 .20 2 3⁄8” 5⁄8” 14UC-29 13” 14” 201⁄8” *2 - 21⁄2 900 .20 2 3⁄8” 3⁄4” 16UC-32 13” 177⁄8” 201⁄8” 21⁄2 1,000 .30 3 3⁄8” 3⁄4” 24UC-35 13” 18 1⁄4” 201⁄8” 3 1,200 .30 2 3⁄8” 3⁄4” 18UC-36 17” 171⁄2” 201⁄8” 3 1,200 .25 2 3⁄8” 3⁄4” 19UC-42 17” 13⁄4” 201⁄8” 31⁄2 1,400 .30 3 3⁄8” 3⁄4” 34UC-47 17” 221⁄8” 201⁄8” 4 1,600 .30 3 3⁄8” 7⁄8” 31UC-49 193⁄4” 217⁄8” 201⁄8” 4 1,600 .30 3 3⁄8” 7⁄8” 33UC-59 193⁄4” 257⁄8” 201⁄8” 5 2,000 .30 3 3⁄8” 7⁄8” 36UC-60 201⁄4” 211⁄4” 23” 5 2,000 .30 3 3⁄8” 7⁄8” 42UC-61 201⁄4” 22” 23” 5 2,000 .30 4 3⁄8” 7⁄8” 44UC-62 191⁄4” 261⁄8” 201⁄8” 5 2,000 .30 4 3⁄8” 7⁄8” 47

NOTES:1) See back sheet for installation tips.2) Do not use this coil on oil furnaces or any applications where the temperature on drain pan may exceed 300°f. Use the following metal drain

pans: 15236-18 (u-18 thru u-32), 15236-19 (u-36 thru u-47), 15236-20 (u/uc-60 thru u-61), and field fabricated metal pan for (u/uc-49, u/uc-59, and u/uc-62).

3) * Uc-29 comes with 2 ton flowrater b13134-59. If 2-1/2 ton matching is required, install provided piston kit b17898-65.

UC-60 & UC-61 Access Panel View

UC-18 thru UC-42, UC-47, UC-49, UC-59, & UC-62 Access Panel View

PRODUCT SPECIFICATIONS

2 3

PRODUCT SPECIFICATIONS

Cased Upflow Evaporator Coils

Model

Dimensions Specifications

A B C D E F NominalTons

NominalCFM

StaticPressureWet Coil

No.Rows

LiquidConn.

SuctionConn.

ShipWeight

(pounds)U-18 141⁄4” 123⁄4” 14” 1⁄2” 131⁄4” - 11⁄2 650 .20 2 3⁄8” 5⁄8” 24U-29 141⁄4” 123⁄4” 14” 1⁄2” 131⁄4” - *2 - 21⁄2 900 .20 2 3⁄8” 3⁄4” 26U-30 181⁄4” 171⁄4” 16” 1⁄2” 171⁄4” - 21⁄2 1,000 .30 2 3⁄8” 3⁄4” 33U-31 141⁄4” 123⁄4” 14” 1⁄2” 131⁄4” - 21⁄2 1,000 .30 3 3⁄8” 3⁄4” 30U-32 181⁄4” 171⁄4” 16” 1⁄2” 171⁄4” 2” 21⁄2 1,000 .25 3 3⁄8” 3⁄4” 41U-35 141⁄4” 121⁄4” 14” 1⁄2” 131⁄4” 41⁄8” 3 1,200 .30 2 3⁄8” 3⁄4” 29U-36 181⁄4” 171⁄4” 16” 1⁄2” 171⁄4” 13⁄4” 3 1,200 .30 2 3⁄8” 3⁄4” 40U-42 181⁄4” 171⁄4” 16” 1⁄2” 171⁄4” 2” 31⁄2 1,400 .30 3 3⁄8” 3⁄4” 48U-47 181⁄4” 171⁄4” 16” 1⁄2” 171⁄4” 6” 4 1,600 .30 3 3⁄8” 7⁄8” 50U-49 211⁄8” 201⁄8” 27” 1⁄2” 20” - 4 1,600 .30 3 3⁄8” 7⁄8” 51U-59 211⁄8” 201⁄8” 27” 1⁄2” 20” - 5 2,000 .30 3 3⁄8” 7⁄8” 54U-60 241⁄4” 231⁄8” 201⁄2” 1⁄2” 201⁄8” 1” 5 2,000 .30 3 3⁄8” 7⁄8” 60U-61 241⁄4” 231⁄8” 201⁄2” 1⁄2” 201⁄8” 15⁄8” 5 2,000 .30 4 3⁄8” 7⁄8” 62U-62 211⁄8” 201⁄8” 27” 1⁄2” 20” - 5 2,000 .30 4 3⁄8” 7⁄8” 68

NOTE: for drain pan specifications, refer to note 2 on page 2.1.) * U-29 comes with 2 ton flowrator b13134-59. If 2 1/2 matching is required, install provided piston KIT B17898-65.

U-60 & U-61 Access Panel View

U-18 thru U-42, U-47, U-49, U-59, & U-62 Access Panel View

PRODUCT SPECIFICATIONS

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.Copyright © 2003 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. • Goodman products are made proudly in the USA.

4

1 Certified per ARI 210 2 BTU/Watt @ 80/67 °F inside - 95 °F outside air 3 M.C.A. (Minimum Circuit Ampacity) 4 M.O.P. (Maximum Overcurrent Protection)

Furnace Model No.

GMP050-3GMP050-32(C)

GMP075-3GMP075-32(C) GMPH050-3GMPN040-3GMPN060-3

GMT045-3 (ND)GMT070-3 (ND)

GMTH045-3 (ND)GSM060-3 (ND)GSMS060-3 (ND)

GSU060-3 (*)

GDT045-3GDT070-3

GMNT040-3GMNT060-3GPD050-3GPD075-3

GMP075-3GMP100-3GMP100-4

GMP100-42(C)GMPE075-3GMPH075-4GMPN080-4

GMT070-4 (ND)GMT090-3 (ND)GMT090-4 (ND)

GMTH070-4 (ND)GSM080-4 (ND)GSMS080-4 (ND)

GSU080-4 (*)

GDT090-4GMNT080-4GPD100-4

GMP100-5GMP125-4GMP125-5

GMP125-52(C)GMPE100-4GMPE125-5GMPH080-5GMPN100-4

GMT090-5 (ND)GMT115-5 (ND)

GMTH115-5 (ND)GSM100-4 (ND)GSMS100-4 (ND)

GSU100-4 (*)

GDT115-5GMNT100-4GPD125-4

GMP150-5GMP150-52(C)GMPH120-5GMPN120-5

GMT140-5 (ND)

GMNT120-5

COILMODEL

NO.

Nominal Furnace Width 14” 14” 17 1⁄2” 17 1⁄2” 21” 21” 24 1⁄2” 24 1⁄2”

DFK Model No.(3) DFK - 14 DFKT-14 DFK - 17 DFKT-17 DFK - 21 DFKT - 21 DFK – 24 DFKT – 24

Nominal Coil Width

U-18 14” X XU-29 14” X XU-30 17 1⁄2” X(1) X(1) X(2) X(2)U-31 14” X XU-32 17 1⁄2” X(1) X(1) X(2) X(2)U-35 14” X XU-36 171⁄2” X(1) X(1) X(2) X(2)U-42 171⁄2” X(1) X(1) X(2) X(2)U-47 171⁄2” X XU-49 21” X(1) X(1) X(2) X(2)U-59 21” X(1) X(1) X(2) X(2)U-60 24 1⁄2” X(1) X(1) X(2) X(2)U-61 24 1⁄2” X(1) X(1) X(2) X(2)U-62 21” X(1) X(1) X(2) X(2)

NOTE:1. Do not use this coil on oil furnaces or any applications where the temperature on drain pan may exceed 300°F. Use the following metal

drain pans: 15236-18 (U-18 thru U-32), 15236-19 (U-36 thru U-47), and 15236-20 (U/UC-60 thru U-61).2. Due to the rating mix/match of various coils with outdoor units it is important to match the furnace air flow for the total system capacity.

(Refer to the furnace sheet & spec. sheet & condenser/heat pump spec. sheet.)

Cased (U) Coil Application Options