  • Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 1

    s

    UTRAN

    Performance Measurement System

    Key Performance Indicators

    A50016-G5000-D528-1-7618 ND-57827-701(E)-01

  • Key Performance Indicators Performance Measurement System

    Copyright (C) Siemens AG / NEC Corporation 2003 Issued by: Siemens AG, Information and Communications Group, Hofmannstrae 51, 81359 Mnchen, Germany and NEC Corporation, 7-1, Shiba 5-chome, Minato-ku, Tokyo, Japan

    Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

    Siemens AG: A50016-G5000-D528-1-76182 NEC Corporation: ND-57827-701(E)-01

    Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 3

    Reason for Update Summary: First issue.

    Details: Chapter/Section Reason for Update All First issue

    Issue history Issue Number/ Version

    Date of Issue Reason for Update

    1 08/2003 First issue

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-76184 NEC Corporation: ND-57827-701(E)-01

    This document consists of a total of 70 pages. All pages are issue 1.

    Contents 1 Introduction ..................................................................................................... 8 1.1 Purpose .......................................................................................................... 8 1.2 Definition of terms........................................................................................... 8 1.3 General Principles .......................................................................................... 9

    2 Call/Connection Analysis.............................................................................. 12 2.1 Call Establishments ...................................................................................... 12 2.1.1 Call setup success rate ................................................................................ 12 2.1.2 RRC Connection Establishments ................................................................. 14 2.1.2.1 RRC connection establishment success rate............................................... 14 2.1.2.2 RRC connection establishment failure rate .................................................. 15 2.1.3 RAB Establishments ..................................................................................... 15 2.1.3.1 RAB establishment success rate.................................................................. 16 2.1.3.2 RAB establishment failure rate ..................................................................... 17 2.1.4 Paging........................................................................................................... 18 2.1.4.1 Paging Failure Rate ...................................................................................... 18 2.2 Connection Release Analysis....................................................................... 19 2.2.1 CN originated release analysis..................................................................... 19 2.2.1.1 Connection Release rate .............................................................................. 19 2.2.2 UTRAN originated release analysis.............................................................. 20 2.2.2.1 Connection Drop Analysis ............................................................................ 20 2.2.2.2 RRC Drop Analysis....................................................................................... 22 2.3 RRC State Transitions.................................................................................. 23 2.3.1 State transition failure rate............................................................................ 23 2.4 Channel Reconfiguration Analysis................................................................ 25 2.4.1 Transport Channel Reconfiguration.............................................................. 25 2.4.1.1 Transport Channel Reconfiguration success rate ........................................ 25 2.4.1.2 Transport Channel Reconfiguration failure rate ........................................... 26 2.4.2 Physical Channel Reconfiguration................................................................ 27 2.4.2.1 Physical Channel Reconfiguration success rate .......................................... 27 2.4.2.2 Physical Channel Reconfiguration failure rate ............................................. 27

    3 Connection Mobility ...................................................................................... 28 3.1 UTRAN updates............................................................................................ 28 3.1.1 Update rate ................................................................................................... 28 3.2 Relocation Preparation ................................................................................. 29 3.2.1 Outgoing Relocations ................................................................................... 29 3.2.1.1 Relocation success rate outgoing................................................................. 29 3.2.1.2 Relocation failure rate outgoing.................................................................... 29 3.2.2 Incoming Relocations ................................................................................... 30 3.2.2.1 Relocation success rate incoming ................................................................ 30 3.3 Soft Handover............................................................................................... 31 3.3.1 Branch addition success rate ....................................................................... 31 3.3.2 Branch addition failure rate........................................................................... 33

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 5

    3.4 Hard Handover ............................................................................................. 37 3.4.1 Outgoing Hard Handover success rate ........................................................ 37 3.4.2 Outgoing Hard Handover failure rate ........................................................... 38 3.4.3 Outgoing Hard Handover drop rate .............................................................. 39 3.5 Inter-System (Inter-RAT) Handover ............................................................. 40 3.5.1 Relocation Preparation (ACM)...................................................................... 40 3.5.1.1 Relocation Preparation failure rate............................................................... 40 3.5.2 Outgoing circuit switched Inter-System Handover ....................................... 41 3.5.2.1 Outgoing CS Inter System Handover success rate...................................... 41 3.5.2.2 Outgoing CS Inter System Handover failure rate ......................................... 42 3.5.2.3 Outgoing CS Inter System Handover drop rate............................................ 44

    4 Quality Indicators.......................................................................................... 46 4.1 Principle ........................................................................................................ 46 4.2 Call establishment quality indicator .............................................................. 46 4.3 Branch Addition quality indicator .................................................................. 46 4.4 Hard handover quality indicator.................................................................... 47 4.5 Inter-System handover quality indicator ....................................................... 47

    5 QuaNTIty Indicators...................................................................................... 48 5.1 RRC State Transitions.................................................................................. 48 5.1.1 Number of successful state transitions......................................................... 48 5.1.2 Number of state transitions to Idle mode...................................................... 49 5.2 Soft Handover............................................................................................... 49 5.2.1 Soft Handover rate ....................................................................................... 49 5.3 Relocations................................................................................................... 50 5.3.1 Number of outgoing relocations ................................................................... 50 5.3.2 Number of incoming relocations................................................................... 50 5.3.3 Outgoing Relocation per Call rate ................................................................ 50 5.4 Hard Handover ............................................................................................. 51 5.4.1 Outgoing Hard Handover per call rate.......................................................... 51 5.5 Inter System Handover................................................................................. 52 5.5.1 Outgoing CS Inter System Handover per call rate ....................................... 52

    6 UtiliZation...................................................................................................... 53 6.1 RNC Load Report ......................................................................................... 53 6.1.1 RNC Processor Load.................................................................................... 53 6.1.2 DHT usage.................................................................................................... 53 6.1.3 DHT allocation success rate......................................................................... 53 6.1.4 PRLC usage ................................................................................................. 53 6.1.5 PRLC allocation success rate ...................................................................... 54 6.2 Node B Load Report..................................................................................... 54 6.2.1 Node B usage rate........................................................................................ 54 6.2.2 Base Band usage rate .................................................................................. 54 6.2.3 Rest of call capacity...................................................................................... 54 6.3 Cell Load Report........................................................................................... 55 6.3.1 Cell Utilisation............................................................................................... 55 6.3.1.1 Code usage rate ........................................................................................... 55

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-76186 NEC Corporation: ND-57827-701(E)-01

    6.3.2 Cell load related Radio Measurements ........................................................ 56 6.3.2.1 Transmitted Carrier power............................................................................ 56 6.3.2.2 Received Total Wide Band Power................................................................ 56 6.4 Radio interface.............................................................................................. 57 6.4.1 Common Channel Load Reports .................................................................. 57 6.4.2 Code allocation success rate........................................................................ 57

    7 Transport Network Layer .............................................................................. 58 7.1 ATM-Layer on RNC side .............................................................................. 58 7.1.1 STM-1 Transmission usage rate .................................................................. 58 7.1.2 STM-1 Receive usage rate........................................................................... 58 7.1.3 STM-1 Transmit/Receive rate....................................................................... 59 7.1.4 E1 Transmit/Receive rate ............................................................................. 59 7.1.5 Cell Loss Ratio.............................................................................................. 59 7.2 ATM-Layer on Node B side .......................................................................... 60 7.2.1 Cell Loss Ratio.............................................................................................. 60 7.2.2 ATM Transmit/Receive rate.......................................................................... 60

    8 Appendix....................................................................................................... 61 8.1 List of Measurements in RNC....................................................................... 61 8.2 List of Measurements in Node B .................................................................. 64 8.3 List of KPIs.................................................................................................... 65

    9 Reference documents .................................................................................. 69

    10 Abbreviations ................................................................................................ 70

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 7

    Illustrations Fig. 2.1 Release Request message and command flow........................................... 20 Fig. 12.1 Success rates of QoS classes...................................................................... 10

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-76188 NEC Corporation: ND-57827-701(E)-01

    1 Introduction

    1.1 Purpose This document is intended to define UTRAN Key Performance Indicators, which give information about quality, performance, load, capacity, .. in a uniform way to the operator. These indicators may be used for the following purposes: Definition of formulas, which are used for realization of predefined reports in the PM+ application of the O&M Toolset (i.e. SPOTS),

    1.2 Definition of terms Each KPI will be described by the following fields:

    Long name This field contains the name of the described KPI.

    Short name This field contains an acronym for the described KPI

    Description This field contains a short explanation of the KPI.

    Formula This field contains the formula for calculation of the KPI.

    Counters This field contains the counters used for calculation of the KPI. Counters are described by the shortname of the measurement and, in brackets, the index of the used counter. The indices are listed with the following meaning: - measType[i] Counter with index #i is used - measType[i,j,k] Counters with indices #i, #j, #k are summarized - measType[i-j] Counters in the index range #i to #j are summarized - measType[all] All counters of the measurement are summarized - measType[i][j] Counter related to index #i with sub-counters index #j are

    used. E.g. index[j] related to CS defined with index #i

    Note: An Index is represented by x,y,z, where x represents the protocol type, y represents the cause categorization and z represents the cause value (see [2]. If specific indices are listed, only the cause values are listed.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 9

    Elementary object This field contains the measured object class the KPI is applicable to. For UMR2.0, this field will only contain the objects RNC, cell, adjacent cell relation, adjacent GERAN cell relation.

    Unit/Range This field contains unit and/or range related to the KPI, e.g. percent.

    Remark This field contains additional information.

    1.3 General Principles (n-1) out of n approach Measurements can be split in 3 sub-measurements number of attempts, number of successes and number of failures where any of the three measurements can be calculated from the two others.

    # of Success + # of Failures = # of Attempts SuccessRate + FailureRate = 100% SuccessRate + FailureRate + DropRate = 100%

    For procedure related KPI analysis it will be defined the Success Rate and the Failure Rate if possible. In case of Hard handover or Inter-System handover a drop rate is added which indicates a failed handover procedure with the consequence that the connection is lost. According the formulas depicted above, one of the rates could be calculated if the other value(s) are known. However, since the measurement recording within the network entities may be out of balance due to failed counting or in case attempts and successful/failed cases are counted within different granularity periods, the adding of the indicated rates may not be exactly 100% in all cases. It will be therefore indicated all rate cases within the document to be able to make a double check of the counters.

    Cause relations For determination of per-cause values the following rules shall apply:

    ][#][#

    ][InitCauseofAttempts

    InitCauseofSuccInitCauseeSuccessRat =

    ][#][#

    ][AllCausesofAttempts

    seFailureCauofFailuresseFailureCaueFailureRat =

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761810 NEC Corporation: ND-57827-701(E)-01

    In case of the Success Rate per init cause, the number of success is related to the number of attempts, where in both terms the init cause shall apply. In case of the Failure Rate per dedicated failure cause, the number of failures is related to the number of attempts, where the dedicated failure cause is related to all causes of the attempts.

    The difference of these calculation rules is based on the target group that evaluates the KPI. The success rates of a procedure refers mainly to Network Planning / Network Optimization groups where the success rate related to the dedicated initialization cause is focused. Thus, e.g. the success rate of the RAB establishment for each QoS class may be depicted in a diagram as follows:

    82%

    84%

    86%

    88%

    90%

    92%

    94%

    Convers. Streaming Interactive Background

    Success Rate

    Fig. 1.1 Success rates of QoS classes

    The dedicated FailureRates of a procedure is mainly used for Troubleshooting. Within this KPI document the definition the ratios of the individual failure causes are depicted related to all attempts. All failure rates per cause added up result in the total failure rate. Of course the indication of the failure rate per initial cause would be advantageous, but this is not possible. In case a failure occur the context of the initialization cause would have to be created which results in a lot of effort and a higher number of measurement counters since for each initialization cause the failure cause has to be stored separately.

    Granularity Period Within this document it is assumed that the KPI is applicable for the same granularity period as defined for the measurements that are utilized within the formulas. Thus, no recommendation is given related to the GP of the KPI. However, the measurements used within one formula may have been activated within separate scanners where different GPs may have been activated. In such a case the O&M Toolset shall consider the different GPs and aggregate the measurements with the lower GPs until the same GP for all measurements apply.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 11

    Call versus Connection Within this document KPIs will be defined analyzing calls and analyzing connections. In our approach calls will be analyzed if a RAB establishment/release is involved. Thus, a call is not related only to a voice connection but also to PS connections. If in the concerned measurements it cannot be distinguished if a RAB is involved or not, e.g. within the iuRelReq counter, then the behavior of connections will be analyzed. I.e. the connection may be related to a call or to signaling only due to SMS transmission or due to Location updates.

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761812 NEC Corporation: ND-57827-701(E)-01

    2 Call/Connection Analysis

    2.1 Call Establishments General assumption: In reference to 3GPP TS 25.931, a call setup will be described by the concatenation of the phases 1. RRC connection establishment (cf. 3GPP TR25.931, chapter 7.3)

    -> covered by measurements rrcEstabAtt, rrcEstabSucc, rrcEstabFail 2. NAS signaling connection establishment (cf. 3GPP TR25.931, chapter 7.2)

    -> pure pass-through of Initial Direct Transfer message; success rate=100% assumed

    3. RAB establishment (cf. 3GPP TR25.931, chapter 7.6) -> covered by measurements rabEstabAtt, rabEstabSucc, rabEstabFail

    Remark, that these phases refer to the UE in IDLE mode, but it is possible to have several RAB establishments in the same RRC connection.

    2.1.1 Call setup success rate Remark, that for the indicated success rate only UTRAN failures are taken into account. In case the Core Network rejects the establishment request from the UE due to internal checks, UTRAN is not able to know the failed NAS procedure.

    Remark, in UMR2.0 following RAB establishment causes are not supported: 1-0 CS streaming 2-0 CS interactive 3-0 CS background 0-1 PS conversational 1-1 PS streaming

    Long name a) Call setup success rate (Access probability) b) User setup success rate (Access probability) c) User setup success rate (multi RAB assignment)

    Short name a) CSSR(AccessProbability) b) USSR(AccessProbability) c) USSR(multiRAB)

    Description This KPI describes the ratio of successful call establishments related to attempts of procedures involved considering success rate of RRC - and RAB Establishment.

    Formula a) %100*

    ][][*

    ]90[]90[)Pr(

    alltrabEstabAtallccrabEstabSu

    trrcEstabAtccrrcEstabSuobabilityAccessCSSR

    =

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 13

    b) %100*

    ][][

    *][

    ]0[][)Pr(

    alltrabEstabAtallccrabEstabSualltrrcEstabAt

    ilrrcEstabFaalltrrcEstabAtobabilityAccessUSSR =

    c) [ ][ ][ ][ ] 100%*t[all]rabEstabAt

    cc[all]rabEstabSu*alltrabEstabAt

    9-0trrcEstabAt1

    ))Pr((*alltrabEstabAt

    9-0trrcEstabAt)(

    += obabilityAccessUSSRmultiRABUSSR

    Counters rrcEstabAtt[all] rrcEstabSucc[all] rabEstabSucc[all] rabEstabAtt[all]

    RAB establishment causes: 0-0 CS conversational 1-0 CS streaming 2-0 CS interactive 3-0 CS background 0-1 PS conversational 1-1 PS streaming 2-1 PS interactive 3-1 PS background

    RRC establishment causes: 3,0,0 Originating conversational call 3,0,1 Originating streaming call 3,0,2 Originating interactive call 3,0,3 Originating background call 3,0,4 Originating subscribed traffic call 3,0,5 Terminating conversational call 3,0,6 Terminating streaming call 3,0,7 Terminating interactive call 3,0,8 Terminating background call 3,0,9 Emergency call 3,0,10 Inter-RAT cell re-selection 3,0,11 Inter-RAT cell change order 3,0,12 Registration 3,0,13 Detach 3,0,14 Originating High Priority Signalling 3,0,15 Originating Low Priority Signalling 3,0,16 Call re-establishment 3,0,17 Terminating High Priority Signalling 3,0,18 Terminating Low Priority Signalling 3,0,19 Terminating cause unknown Other other causes

    RRC establishment failure causes: 3,0,0 Congestion 3,0,1 Unspecified NoReply No reply other Other failure cause

    Object Cell Unit/Range Percent

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761814 NEC Corporation: ND-57827-701(E)-01

    Remark The main difference between call setup and user setup success rate is that with the USSR only the failures due to congestion are supposed to impact the access probability in the user perspective.

    2.1.2 RRC Connection Establishments

    2.1.2.1 RRC connection establishment success rate

    Long name RRC connection establishment success rate a) RRC connection establishment success rate (MO call) b) RRC connection establishment success rate (MT call) c) RRC connection establishment success rate (Establishment cause)

    Short name a) RrcEstabSR b) RrcEstabSR(MO) c) RrcEstabSR(MT) d) RrcEstabSR(EstabCause)

    Description This KPI describes the ratio of successful RRC connection establishments related to the total number of RRC connection establishment attempts.

    Formula a) %100*

    ][][

    alltrrcEstabAtallccrrcEstabSuRrcEstabSR =

    b) %100*]9,40[]9,40[)(

    =

    trrcEstabAtccrrcEstabSuMORrcEstabSR

    c) %100*]85[]85[)(

    =

    trrcEstabAtccrrcEstabSuMTRrcEstabSR

    d) %100*][][)(

    itrrcEstabAticcrrcEstabSuEstabCauseRrcEstabSR =

    Counters rrcEstabSucc[all] rrcEstabAtt[all]

    RRC establishment causes: 3,0,0 Originating conversational call 3,0,1 Originating streaming call 3,0,2 Originating interactive call 3,0,3 Originating background call 3,0,4 Originating subscribed traffic call 3,0,5 Terminating conversational call 3,0,6 Terminating streaming call 3,0,7 Terminating interactive call 3,0,8 Terminating background call 3,0,9 Emergency call 3,0,10 Inter-RAT cell re-selection 3,0,11 Inter-RAT cell change order 3,0,12 Registration 3,0,13 Detach 3,0,14 Originating High Priority Signaling

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 15

    3,0,15 Originating Low Priority Signaling 3,0,16 Call re-establishment 3,0,17 Terminating High Priority Signaling 3,0,18 Terminating Low Priority Signaling 3,0,19 Terminating cause unknown Other other causes

    Object Cell Unit/Range Percent Remark

    2.1.2.2 RRC connection establishment failure rate

    Long name a) RRC connection establishment failure rate b) RRC connection establishment failure rate (Failure cause)

    Short name a) RrcEstabFR b) RrcEstabFR(Failure)

    Description This KPI describes the ratio of unsuccessful RRC connection establishments related to all RRC connection establishment attempts.

    Formula a) %100*

    ][][

    alltrrcEstabAtallilrrcEstabFaRrcEstabFR =

    b) %100*][][)(

    alltrrcEstabAtiilrrcEstabFaFailureRrcEstabFR =

    Counters rrcEstabAtt[all] rrcEstabFail[all]

    RRC establishment failure causes: 3,0,0 Congestion 3,0,1 Unspecified NoReply No reply other Other failure cause

    Object Cell Unit/Range Percent Remark

    2.1.3 RAB Establishments

    Remark, in UMR2.0 following RAB establishment causes are not supported: 1-0 CS streaming 2-0 CS interactive 3-0 CS background 0-1 PS conversational 1-1 PS streaming

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761816 NEC Corporation: ND-57827-701(E)-01

    2.1.3.1 RAB establishment success rate

    Long name a) RAB establishment success rate b) RAB establishment success rate (CS) c) RAB establishment success rate (PS) d) RAB establishment success rate (QoS class)

    Short name a) RabEstabSR b) RabEstabSR(CS) c) RabEstabSR(PS) d) RabEstabSR(QoS)

    Description This KPI describes the ratio of successful RAB establishments related to the total number of RAB establishment attempts.

    Formula a) %100*

    ][][

    alltrabEstabAtallccrabEstabSuRabEstabSR =

    b) %100*]0][30[]0][30[)(

    =

    trabEstabAtccrabEstabSuCSRabEstabSR

    c) %100*]1][30[]1][30[)(

    =

    trabEstabAtccrabEstabSuPSRabEstabSR

    d) %100*][][)(

    itrabEstabAticcrabEstabSuQoSRabEstabSR =

    Counters rabEstabSucc[all] rabEstabAtt[all]

    RAB establishment causes: 0-0 CS, conversational 1-0 CS, streaming 2-0 CS, interactive 3-0 CS, background 0-1 PS, conversational 1-1 PS, streaming 2-1 PS, interactive 3-1 PS, background

    Object Cell Unit/Range Percent Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 17

    2.1.3.2 RAB establishment failure rate

    Long name a) RAB establishment failure rate b) RAB establishment failure rate (CS) c) RAB establishment failure rate (PS) d) RAB establishment failure rate (Failure cause)

    Short name a) RabEstabFR b) RabEstabFR(CS) c) RabEstabFR(PS) d) RabEstabFR(Failure)

    Description This KPI describes the ratio of unsuccessful RAB establishments related to the total number of all RAB establishment attempts

    Formula a) %100*

    ][][

    alltrabEstabAtallilrabEstabFaRabEstabFR =

    b) %100*]0][30[]][0[)(

    =

    trabEstabAtallilrabEstabFaCSRabEstabFR

    c) %100*]1][30[]][1[)(

    =

    trabEstabAtallilrabEstabFaPSRabEstabFR

    d) %100*][][)(

    alltrabEstabAtiilrabEstabFaFailureRabEstabFR =

    Counters rabEstabAtt[all] rabEstabFail[all]

    RAB failure rates: 0-2,4,6 CS, Relocation triggered 0-2,4,8 CS, Unabled to establish during relocation 0-2.4.12 CS, Requested ciphering and/or integrity protection algorithms not supported 0-2,4,14 CS, Failure in the radio interface procedure 0-2,4,18 CS, Requested traffic class not available 0-2,4,19 CS, Invalid RAB parameters value 0-2,4,23 CS, Invalid RAB parameters combination 0-2,4,24 CS, Condition violation for SDU parameters 0-2,4,30 CS, Invalid RAB ID 0-2,4,32 CS, Interaction with other procedure 0-2,4,39 CS, Request superseded 0-2,4,66 CS, Iu transport connection failed to establish 0-2,4,97 CS, Transfer syntax error 0-2,4,98 CS, Semantic error 0-2,4,99 CS, Message not compatible with receiver state 0-2,4,100 CS, Abstract syntax error (reject) 0-2,4,101 CS, Abstract syntax error (ignore and notify) 0-2,4,102 CS, Abstract syntax error (falsely constructed message) 0-2,4,114 CS, No ressource available 0-2,4,115 CS, Unspecified failure 0-other CS, Other failure cause 1-2,4,6 PS, Relocation triggered 1-2,4,8 PS, Unabled to establish during relocation 1-2.4.12 PS, Requested ciphering and/or integrity protection algorithms not supported

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761818 NEC Corporation: ND-57827-701(E)-01

    1-2,4,14 PS, Failure in the radio interface procedure 1-2,4,18 PS, Requested traffic class not available 1-2,4,19 PS, Invalid RAB parameters value 1-2,4,23 PS, Invalid RAB parameters combination 1-2,4,24 PS, Condition violation for SDU parameters 1-2,4,30 PS, Invalid RAB ID 1-2,4,32 PS, Interaction with other procedure 1-2,4,39 PS, Request superseded 1-2,4,66 PS, Iu transport connection failed to establish 1-2,4,97 PS, Transfer syntax error 1-2,4,98 PS, Semantic error 1-2,4,99 PS, Message not compatible with receiver state 1-2,4,100 PS, Abstract syntax error (reject) 1-2,4,101 PS, Abstract syntax error (ignore and notify) 1-2,4,102 PS, Abstract syntax error (falsely constructed message) 1-2,4,114 PS, No resource available 1-2,4,115 PS, Unspecified failure 1-other PS, Other failure cause RAB establishment causes: 0-0 CS, conversational 1-0 CS, streaming 2-0 CS, interactive 3-0 CS, background 0-1 PS, conversational 1-1 PS, streaming 2-1 PS, interactive 3-1 PS, background

    Object Cell Unit/Range Percent Remark

    2.1.4 Paging

    2.1.4.1 Paging Failure Rate

    Long name a) Paging Failure Rate in Cell_PCH state b) Paging Failure Rate in URA_PCH state

    Short name a) PagingFailureCell_PCH b) PagingFailureURA_PCH

    Description This KPI describes the ratio of Paging failures, i.e. no response to Paging-type 1 received or receipt of RRC STATUS message in response to Paging-Type 1 indicating protocol error, related to the total number of Pagings in CELL_PCH/URA_PCH state.

    Formula a) %100*

    ][1][_

    allCellUtranpagingallFailpagingCellPCHureCellPagingFail =

    b) %100*][1

    ][_allUraUtranpagingallailpagingUraFPCHureURAPagingFail =

    Counters pagingCellFail[all]

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 19

    paging1CellUtran[all]

    Paging failure causes: 3,3,0 ASN.1 violation or encoding error 3,3,1 Message type non-existent or not implemented 3,3,2 Message not compatible with receiver state 3,3,3 Information element value not comprehended 3,3,4 Conditional information element error 3,3,5 Message extension not comprehended NoReply No reply Other Other causes Paging causes in Cell_PCH/URA_PCH state: 3,0,6 Terminating cause unknown Other Other causes

    Object Cell Unit/Range Percent Remark

    2.2 Connection Release Analysis

    2.2.1 CN originated release analysis Connection release analysis CN originated investigates the release causes on connection releases from CN. By these KPIs the normal connection releases and un-normal connection releases i.e. connection release due to failure from CN side or UTRAN side shall be distinguished.

    2.2.1.1 Connection Release rate

    Long name a) Normal Connection release rate b) Unnormal connection release rate c) Connection release rate (Release cause)

    Short name a) NormalCRR b) UnNormalCRR c) CRR(ReleaseCause)

    Description This KPI describes the ratio of normal CN initiated connection releases related to the total number of CN initiated connection releases.

    Formula a) %100*

    ][Re]83,31,16,11,10[Re

    alllCmdiulCmdiuNormalCRR =

    b) %100*][Re

    ],115,45,40,28,15[RealllCmdiu

    otherlCmdiuRUnNormalCR =

    c) %100*][Re

    ][Re)(RealllCmdiuilCmdiuleaseCauseCRR =

    Counters iuRelCmd[all]

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761820 NEC Corporation: ND-57827-701(E)-01

    Iu release causes: 2,4,10 Relocation Cancelled (Normal) 2,4,11 Successful Relocation (Normal) 2,4,15 Release due to UTRAN Generated Reason (Failure, Initiated by Iu Rel

    Req) 2,4,16 User inactivity (Normal) 2,4,28 Iu UP failure (Failure) 2,4,31 No Remaining RAB (Normal) 2,4,40 Release due to UE generated signaling connection release (Failure,

    Initiated by Iu Rel Req) 2,4,45 Directed retry (Failure, Initiated by Iu Rel Req) 2,6,83 Normal Release (Normal) 2,8,115 Unspecified Failure (Failure) Other other cause (Unknown)

    Object Cell Unit/Range Percent Remark

    2.2.2 UTRAN originated release analysis Connection release analysis UTRAN originated refers only to un-normal releases UTRAN originated i.e. existing connections have been lost at UTRAN side. KPIs in this subsection analyze the connection drop rates by means of release indication toward the CN and the RRC connection drop rate.

    2.2.2.1 Connection Drop Analysis The un-normal release of a connection UTRAN originated is indicated either by the RAB RELEASE REQUEST message or the IU RELEASE REQUEST message transmitted from the RNC to the CN. The RAB RELEASE REQUEST message will be used when the failure occurs in the RAB management as e.g. firmware failure PRLC, DHT,... In any case the UE is still reachable via a RRC connection. The IU RELEASE REQUEST message is used in case the UE is lost at the air interface. The CN will response either with the RANAP message RAB ASSIGNMENT REQUEST indicating the RAB to be released if another parallel transaction is still ongoing or with the IU RELEASE COMMAND message.

    iuRelReq

    iuRelReq

    iuRelCmd

    RNC MSC

    Fig. 2.1 Release Request message and command flow

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 21

    For evaluation of the connection drop rates following aspects have to be considered impacting the KPI result: If the dropped connection was related to a call or to a signaling connection, which

    was established for registration or signaling, cannot be distinguished. I.e. service related call drops, which are intentionally preferred to measure, cannot be distinguished from RRC connections dropped by UTRAN.

    In case the transmitted RAB RELEASE REQUEST message from the RNC to the CN will be acknowledged by the RAB ASSIGNMENT REQUEST message from the CN because a parallel transaction is still running, the rabRel counter in UMR2.0 will count the same event twice.

    In case that the established connection is in Softer/Soft handover when the connection loss occur and the RNC transmits the RAB RELEASE REQUEST message the rabRel counter will be incremented in all cells of existing radio links. Thus, including the rabRel counter in the drop rate calculation means that the drop rate is calculated depending the existing radio links and not per RAB establishments.

    As a consequence of the falsification by the rabRel counter, the rabRel counter is not considered for the drop analysis toward the CN. Thus, the calculated drop rate is not quite correct but the drops caused from internal RNC failures should be much less compared to the loss of the UE.

    2.2.2.1.1 Connection drop rate

    Long name a) Connection drop rate b) Connection drop rate (CS) c) Connection drop rate (PS) d) Connection drop rate (Drop cause)

    Short name a) ConDR b) ConDR(CS) c) ConDR(PS) d) ConDR(DropCause)

    Description This KPI describes the ratio between the number of abnormal call releases and the number of released calls.

    Formula

    a) %100*][Re

    ],113,46,40,37,28,15,14][1[ReRe],113,46,40,37,28,15,14][0[ReRe

    alllCmdiuotherqliuotherqliu

    ConDR

    +

    =

    b) %100*]][0[Re

    ],113,46,40,37,28,15,14][0[ReRe)(

    alllCmdiuotherqliuCSConDR =

    c) %100*]][1[Re

    ],113,46,40,37,28,15,14][1[ReRe)(

    alllCmdiuotherqliuPSConDR =

    d) %100*][Re

    ][ReRe)(

    alllCmdiuiqliuDropCauseConDR =

    Counters iuRelReq[i] iuRelCmd[all]

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761822 NEC Corporation: ND-57827-701(E)-01

    Iu release request causes: 0-2,4,14 CS, Failure in the Radio IF Procedure 0-2,4,15 CS, Release due to UTRAN generated reason 0-2,4,16 CS, User inactivity 0-2,4,28 CS, Iu UP failure 0-2,4,37 CS, Repeated Integrity checking fail 0-2,4,40 CS, Release due to UE generated signaling connection release 0-2,4,45 CS, Directed retry 0-2,4,46 CS, Radio connection with UE lost 0-2,8,113 CS, O&M intervention 0-Other CS, Other cause 1-2,4,14 PS, Failure in the Radio IF Procedure 1-2,4,15 PS, Release due to UTRAN generated reason 1-2,4,16 PS, User inactivity 1-2,4,28 PS, Iu UP failure 1-2,4,37 PS, Repeated Integrity checking fail 1-2,4,40 PS, Release due to UE generated signaling connection release 1-2,4,45 PS, Directed retry 1-2,4,46 PS, Radio connection with UE lost 1-2,8,113 PS, O&M intervention 1-Other PS, Other cause

    Object Cell Unit/Range Percent Remark

    2.2.2.2 RRC Drop Analysis RRC drop describes the loss of a RRC connection with exceptional cause.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 23

    2.2.2.2.1 RRC drop rate

    Long name a) RRC drop rate b) RRC drop rate (Drop cause)

    Short name a) RRCDR b) RRCDR(DropCause)

    Description This KPI describes the ratio between the number of abnormal RRC connection releases and the number of successful established RRC connections.

    Formula a) %100*

    ][],41[Re],41[Re

    allccrrcEstabSuotherlCcchrrcotherlDcchrrcRRCDR +=

    b) %100*][

    ][Re][Re)(allccrrcEstabSu

    ilCcchrrcilDcchrrcDropCauseRRCDR +=

    Counters rrcEstabSucc[all] rrcRelDcch[i] rrcRelCcch[i] RRC release causes: 3,0,0 Normal event 3,0,1 Unspecified 3,0,2 Pre-emptive release 3,0,3 Congestion 3,0,4 Re-establishment reject 3,0,5 Directed signaling connection re-establishment 3,0,6 User inactivity other Other release cause

    Object Cell Unit/Range Percent Remark

    2.3 RRC State Transitions

    2.3.1 State transition failure rate

    Long name

    a) Cell_DCH state transition failure rate (Target state) b) Cell_FACH state transition failure rate (Target state) c) Cell_PCH state transition failure rate (Target state) d) URA_PCH state transition failure rate (Target state) e) Cell_DCH state transition failure rate (Target state, Failure cause) f) Cell_FACH state transition failure rate (Target state, Failure cause) g) Cell_PCH state transition failure rate (Target state, Failure cause) h) URA_PCH state transition failure rate (Target state, Failure cause)

    Short name

    a) Cell_DCHSTFR(Target) b) Cell_FACHSTFR(Target) c) Cell_PCHSTFR(Target) d) URA_PCHSTFR(Target) e) Cell_DCHSTFR(Target,Failure)

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761824 NEC Corporation: ND-57827-701(E)-01

    f) Cell_FACHSTFR(Target,Failure) g) Cell_PCHSTFR(Target, Failure) h) URA_PCHSTFR(Target,Failure)

    Description

    This KPI describes the ratio of unsuccessful State transitions from the originating state to the individual target state per failure cause related to the number of State transition attempts.

    Formula a) %100*

    ]1[]][1[)1(_

    ellDchAtttransFromCallellDchFailtransFromCDCHSTFRCell =

    b) %100*]3,2,0[

    ]][3,2,0[)3,2,0(_ellFachAtttransFromC

    alllellFachFaitransFromCFACHSTFRCell =

    c) %100*]1[

    ]][1[)1(_ellPchAtttransFromC

    allellPchFailtransFromCPCHSTFRCell =

    d) %100*]1[

    ]][1[)1(_raPchAtttransFromU

    allraPchFailtransFromUPCHSTFRURA =

    e) %100*]1[

    ]][1[),1(_ellDchAtttransFromC

    iellDchFailtransFromCFailureDCHSTFRCell =

    f) %100*]3,2,0[

    ]][3,2,0[),3,2,0(_ellFachAtttransFromC

    ilellFachFaitransFromCFailureFACHSTFRCell =

    g) %100*]1[

    ]][1[),1(_ellPchAtttransFromC

    iellPchFailtransFromCFailurePCHSTFRCell =

    h) %100*]1[

    ]][1[),1(_raPchAtttransFromU

    iraPchFailtransFromUFailurePCHSTFRURA =

    Counters transFromCell****Att[Target] transFromCell****Fail[Target][all] State transition failure causes: 3,2,0 Configuration unsupported 3,2,1 Physical channel failure 3,2,2 Incompatible simultaneous reconfiguration 3,2,3 Protocol error 3,2,4 Compressed mode runtime error 3,2,5 Cell update occurred 3,2,6 Invalid configuration 3,2,7 Configuration incompatible NoReply No reply Other Other causes Target states: 0 CELL_DCH 1 CELL_FACH 2 CELL_PCH 3 URA_PCH

    Object Cell RNC for transitions from URA_PCH state

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 25

    Unit/Range

    Percent

    Remark

    2.4 Channel Reconfiguration Analysis

    2.4.1 Transport Channel Reconfiguration

    2.4.1.1 Transport Channel Reconfiguration success rate

    Long name Transport Channel reconfiguration success rate Short name TChReconfSR Description This KPI describes the ratio of successful transport channel reconfigurations related to

    total number of transport channel reconfiguration attempts. Formula

    %100*Re

    ReReconfAtttraChconfSucctraChconfSRTCh =

    Counters traChReconfSucc traChReconfAtt

    Object Cell Unit/Range Percent Remark

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761826 NEC Corporation: ND-57827-701(E)-01

    2.4.1.2 Transport Channel Reconfiguration failure rate

    Long name a) Transport Channel reconfiguration failure rate b) Transport Channel reconfiguration failure rate (Failure cause)

    Short name a) TChReconfFR b) TChReconfFR(Fail)

    Description This KPI describes the ratio of unsuccessful transport channel reconfigurations related to total number of transport channel reconfiguration attempts.

    Formula a) %100*

    Re][Re

    ReconfAtttraCh

    allconfFailtraChconfFRTCh =

    b) %100*Re

    ][Re)(ReconfAtttraCh

    iconfFailtraChFailconfFRTCh =

    Counters traChReconfFail[all] traChReconfAtt

    Transport channel reconfiguration failure causes: 3,2,0 Configuration unsupported 3,2,1 Physical channel failure 3,2,2 Incompatible simultaneous reconfiguration 3,2,3 Protocol error 3,2,4 Compressed mode runtime error 3,2,5 Cell update occurred 3,2,6 Invalid configuration 3,2,7 Configuration incompatible NoReply No reply Other Other causes

    Object Cell Unit/Range Percent Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 27

    2.4.2 Physical Channel Reconfiguration

    2.4.2.1 Physical Channel Reconfiguration success rate

    Long name Physical Channel reconfiguration success rate Short name PhyChReconfSR Description This KPI describes the ratio of successful physical channel reconfigurations related to

    total number of physical channel reconfiguration attempts. Formula

    %100*Re

    ReReconfAttphyChconfSuccphyChconfSRPhyCh =

    Counters phyChReconfSucc phyChReconfAtt

    Object Cell Unit/Range Percent Remark

    2.4.2.2 Physical Channel Reconfiguration failure rate

    Long name a) Physical Channel reconfiguration failure rate b) Physical Channel reconfiguration failure rate (Failure cause)

    Short name a) PhyChReconfFR b) PhyChReconfFR(Fail)

    Description This KPI describes the ratio of unsuccessful physical channel reconfigurations related to total number of physical channel reconfiguration attempts.

    Formula a) %100*

    Re][Re

    ReconfAttphyCh

    allconfFailphyChconfFRPhyCh =

    b) %100*Re

    ][Re)(ReconfAttphyCh

    iconfFailphyChFailconfFRPhyCh =

    Counters phyChReconfFail[all] phyChReconfAtt

    Physical channel reconfiguration failure causes: 3,2,0 Configuration unsupported 3,2,1 Physical channel failure 3,2,2 Incompatible simultaneous reconfiguration 3,2,3 Protocol error 3,2,4 Compressed mode runtime error 3,2,5 Cell update occurred 3,2,6 Invalid configuration 3,2,7 Configuration incompatible NoReply No reply Other Other causes

    Object Cell Unit/Range Percent Remark

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761828 NEC Corporation: ND-57827-701(E)-01

    3 Connection Mobility

    3.1 UTRAN updates

    3.1.1 Update rate

    Long name a) Cell update rate (Update cause) b) URA update rate (Update cause)

    Short name a) CellUpdateRate(UpdateCause) b) URAUpdateRate(UpdateCause)

    Description This KPI describes the ratio of cell/ura updates per update cause related to the total number of cell/ura updates.

    Formula a) %100*

    ][][

    )(allcellUpdateicellUpdateeUpdateCausRateCellUpdate =

    b) %100*][

    ][)(

    alluraUpdateiuraUpdateeUpdateCausateUraUpdateR =

    Counters cellUpdate[all] uraUpdate[all]

    Cell update causes: 3,0,0 Cell reselection 3,0,1 Periodical cell update 3,0,2 Uplink data transmission 3,0,3 Paging response 3,0,4 Re-entered service area 3,0,5 Radio link failure 3,0,6 RLC unrecoverable error Other Other cause

    URA update causes: 3,0,0 Change of URA 3,0,1 Periodic URA update 3,0,2 Re-entered service area Other Other cause

    Object Cell Unit/Range Percent Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 29

    3.2 Relocation Preparation

    3.2.1 Outgoing Relocations

    3.2.1.1 Relocation success rate outgoing

    Long name a) Relocation success rate outgoing b) Relocation success rate outgoing(Relocation cause)

    Short name a) RelocOutSR b) RelocOutSR(RelocationCause)

    Description This KPI describes the ratio of successful outgoing relocations related to the total number of outgoing relocation attempts.

    Formula a) %100*

    ][][Re

    alltrelocOutAtallccrelocOutSulocOutSR =

    b) %100*][][)(ReRe

    itrelocOutAticcrelocOutSuuselocationCalocOutSR =

    Counters relocOutSucc[all] relocOutAtt[all]

    Relocation causes: 2,4,41 Resource optimisation relocation 2,4,43 Relocation desirable for radio reasons 2,4,45 Directed Retry other other causes

    Object RNC Unit/Range Percent Remark

    3.2.1.2 Relocation failure rate outgoing

    Long name a) Relocation failure rate outgoing b) Relocation failure rate outgoing (Relocation failure cause)

    Short name a) RelocOutFR b) RelocOutFR(RelocationFailureCause)

    Description This KPI describes the ratio of unsuccessful outgoing relocations related to the total number of outgoing relocation attempts.

    Formula a) %100*

    ][][Re

    alltrelocOutAtallilrelocOutFalocOutFR =

    b) %100*][][)(ReRe

    alltrelocOutAtiilrelocOutFailureCauselocationFalocOutFR =

    Counters relocOutFail[all] relocOutAtt[all]

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761830 NEC Corporation: ND-57827-701(E)-01

    Relocation failure causes: 2,4,7 TRELOCalloc expiry 2,4,9 Unknown target RNC 2,4,10 relocation cancelled 2,4,29 relocation failure in Target CN or target system 2,4,44 relocation not supported in target system Other other failure cause during relocation preparation

    Object RNC Unit/Range Percent Remark

    3.2.2 Incoming Relocations

    3.2.2.1 Relocation success rate incoming

    Long name a) Relocation success rate incoming b) Relocation success rate incoming (Relocation cause)

    Short name a) RelocIncSR b) RelocIncSR(RelocationCause)

    Description This KPI describes the ratio of successful incoming relocations related to the total number of incoming relocation attempts.

    Formula a) %100*

    ][][Re

    alltrelocIncAtallccrelocIncSulocIncSR =

    b) %100*][][)(ReRe

    itrelocIncAticcrelocIncSuuselocationCalocIncSR =

    Counters relocIncSucc[all] relocIncAtt[all]

    Relocation causes: 2,4,41 Resource optimisation relocation 2,4,43 Relocation desirable for radio reasons 2,4,45 Directed Retry other other causes

    Object RNC Unit/Range Percent Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 31

    3.3 Soft Handover

    3.3.1 Branch addition success rate

    a) Per cell related measurements:

    Long name a) Branch addition success rate b) Branch addition success rate (Intra Node B) c) Branch addition success rate (Intra RNC) d) Branch addition success rate (InterRNC) e) Branch addition success rate (Addition cause) f) Intra Node B branch addition success rate (Addition cause) g) Intra RNC branch addition success rate (Addition cause) h) Inter RNC branch addition success rate (Addition cause)

    Short name a) BranchAddSR b) BranchAddSR(IntraNodeB) c) BranchAddSR(IntraRNC) d) BranchAddSR(InterRNC) e) BranchAddSR(Addition cause) f) IntraNBBranchAddSR(AdditionCause) g) IntraRNCBranchAddSR(AdditionCause) h) InterRNCBranchAddSR(AdditionCause)

    Description This KPI describes the ratio of successful branch additions related to the total number of branch addition attempts.

    Formula

    a) %100*

    ][][

    ][][][

    ][

    allrRncAttshoAddInteallaRncAttshoAddIntr

    allaNodeBAttshoAddIntrallrRncSuccshoAddInteallaRncSuccshoAddIntr

    allaNodeBSuccshoAddIntr

    RBranchAddS

    +

    +

    +

    +

    =

    b) %100*][][)(

    allaNodeBAttshoAddIntrallaNodeBSuccshoAddIntrIntraNodeBRBranchAddS =

    c) %100*][][)(

    allaRncAttshoAddIntrallaRncSuccshoAddIntrIntraRNCRBranchAddS =

    d) %100*][][)(

    allrRncAttshoAddInteallrRncSuccshoAddInteInterRNCRBranchAddS =

    e) %100*

    ][][

    ][][][

    ][

    )(

    irRncAttshoAddInteiaRncAttshoAddIntr

    iaNodeBAttshoAddIntrirRncSuccshoAddInteiaRncSuccshoAddIntr

    iaNodeBSuccshoAddIntr

    useAdditionCaRBranchAddS

    +

    +

    +

    +

    =

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761832 NEC Corporation: ND-57827-701(E)-01

    f) %100*][][)(

    iaNodeBAttshoAddIntriaNodeBSuccshoAddIntruseAdditionCanchAddSRIntraNBBra =

    g) %100*][][)(

    iaRncAttshoAddIntriaRncSuccshoAddIntruseAdditionCaanchAddSRIntraRNCBr =

    h) %100*][][)(

    irRncAttshoAddInteirRncSuccshoAddInteuseAdditionCaanchAddSRInterRNCBr =

    Counters shoAddIntraNodeBSucc[all] shoAddIntraRncSucc[all] shoAddInterRncSucc[all] shoAddIntraNodeBAtt[all] shoAddIntraRncAtt[all] shoAddInterRncAtt[all]

    SHO addition cause: 1,0,1 CPICH comparison (1A) 1,0,2 CPICH comparison (1A) 1,0,4 CPICH comparison (1C) Other other causes

    Object Cell Unit/Range Percent Remark Remark, the measured object is the cell, which has been added to the active link (set).

    b) Per adjacent cell related measurements:

    Long name a) Branch addition success rate (Cell related) b) Branch addition success rate (ACR)

    Short name a) BranchAddSRACR(Cell) b) BranchAddSRACR(ACR)

    Description This KPI describes the ratio of successful branch additions related to the total number of branch addition attempts per adjacent cell measurement.

    Formula

    a) %100*)(AttshoMoveOut

    SuccshoMoveOutCellRACRBranchAddS

    ACR

    ACR

    =

    b) %100*)(AttshoMoveOutSuccshoMoveOutACRRACRBranchAddS =

    Counters shoMoveOutSucc shoMoveOutAtt

    Object a) Cell b) Adjacent cell

    Unit/Range Percent Remark a) This calculation provides the cell related branch addition success rate. I.e. the

    success rate belongs to the added cell from all cell relations. b) This calculation provides the adjacent cell related branch addition success rate.

    Calculation of the success rate per individual cell relation.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 33

    Remark, the measured object in both cases is the cell, which has been added to the active link set.

    3.3.2 Branch addition failure rate

    a) Per cell related measurements:

    Long name a) Branch addition failure rate b) Branch addition failure rate (Intra Node B) c) Branch addition failure rate (Intra RNC) d) Branch addition failure rate (Inter RNC) e) Branch addition failure rate (Failure cause) f) Intra Node B branch addition failure rate (Failure cause) g) Intra RNC branch addition failure rate (Failure cause) h) Inter RNC branch addition failure rate (Failure cause)

    Short name a) BranchAddFR b) BranchAddFR(IntraNodeB) c) BranchAddFR(IntraRNC) d) BranchAddFR(InterRNC) e) BranchAddFR(FailureCause) f) IntraNBBranchAddFR(FailureCause) g) IntraRNCBranchAddFR(FailureCause) h) InterRNCBranchAddFR(FailureCause)

    Description These KPIs describes the ratio of unsuccessful branch additions related to the total number of branch addition attempts.

    Formula

    a) %100*

    ][][

    ][][][

    ][

    allrRncAttshoAddInteallaRncAttshoAddIntr

    allaNodeBAttshoAddIntrallrRncFailshoAddInteallaRncFailshoAddIntr

    allaNodeBFailshoAddIntr

    RBranchAddF

    +

    +

    +

    +

    =

    b) %100*][][)(

    allaNodeBAttshoAddIntrallaNodeBFailshoAddIntrIntraNodeBRBranchAddF =

    c) %100*][][)(

    allaRncAttshoAddIntrallaRncFailshoAddIntrIntraRNCRBranchAddF =

    d) %100*][][)(

    allrRncAttshoAddInteallrRncFailshoAddInteInterRNCRBranchAddF =

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761834 NEC Corporation: ND-57827-701(E)-01

    e) %100*

    ][][

    ][][][

    ][

    )(

    allrRncAttshoAddInteallaRncAttshoAddIntr

    allaNodeBAttshoAddIntrirRncFailshoAddInteiaRncFailshoAddIntr

    iaNodeBFailshoAddIntr

    seFailureCauRBranchAddF

    +

    +

    +

    +

    =

    f) %100*][][)(

    allaNodeBAttshoAddIntriaNodeBFailshoAddIntrseFailureCaunchAddFRIntraNBBra =

    g) %100*][][)(

    allaRncAttshoAddIntriaRncFailshoAddIntrseFailureCauanchAddFRIntraRNCBr =

    h) %100*][][)(

    allrRncAttshoAddInteirRncFailshoAddInteseFailureCauanchAddFRInterRNCBr =

    Counters shoAddIntraNodeBFail[all] shoAddIntraRncFail[all] shoAddInterRncFail[all] shoAddIntraNodeBAtt[all] shoAddIntraRncAtt[all] shoAddInterRncAtt[all]

    SHO failure causes. 6,4,0 Unknown C-Id 6,4,1 Cell not available 6,4,2 Power Level not supported 6,4,3 DL Radio Resources not available 6,4,4 UL Radio Resources not available 6,4,5 RL already activated/allocated 6,4,6 Node B Resources unavailable 6,4,7 Combining resources not available 6,4,8 Requested Configuration not supported 6,4,9 Unspecified (Radio Network Layer Cause) 6,4,10 Measurement temporarily not available 6,4,11 Invalid CM Settings 6,4,12 Reconfiguration CFN not elapsed 6,4,13 Number of DL codes not supported 6,4,14 Combining not supported 6,4,15 UL SF not supported 6,4,16 DL SF not supported 6,4,17 Dedicated transport channel type not supported 6,4,18 CM not supported 6,4,19 UL Scrambling Code Already in use 6,4,20 Transaction not supported by Destination Node B 6,4,21 Number of UL codes not supported 6,5,0 Transport resources unavailable 6,5,1 Unspecified (Transport Layer Cause)

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 35

    6,7,0 Transfer Syntax Error 6,7,1 Abstract Syntax Error (Reject) 6,7,2 Abstract Syntax Error (Ignore and Notify) 6,7,3 Message not compatible with Receiver State 6,7,4 Semantic Error 6,7,5 Unspecified (Protocol Cause) 6,7,6 Abstract Syntax Error (Falsely Constructed Message) 6,8,0 Control processing overload 6,8,1 HW failure 6,8,2 O&M Intervention 6,8,3 Not enough User Plane Processing Resources 6,8,4 Unspecified (Miscellaneous Cause) 3,2,0 Configuration unsupported 3,2,1 Physical channel failure 3,2,2 Incompatible simultaneous reconfiguration 3,2,3 Protocol error 3,2,4 Compressed mode runtime error 3,2,5 Cell reselection 3,2,6 Invalid configuration 3,2,7 Configuration incomplete 3,2,8 Unsupported measurement NoReply No reply Other other causes

    Object Cell Unit/Range Percent Remark Remark, the measured object is the cell, which has been added to the active link set.

    b) Per adjacent cell related measurements:

    Long name a) Branch addition failure rate (Cell related) b) Branch addition failure rate (ACR) c) Branch addition failure rate (Cell,Failure cause) d) Branch addition failure rate (ACR,Failure cause)

    Short name a) BranchAddFRACR(Cell) b) BranchAddFRACR(ACR) c) BranchAddFRACR(Cell,FailureCause) d) BranchAddFRACR(ACR,FailureCause)

    Description This KPI describes the ratio of unsuccessful branch additions per adjacent cell related to the total number of branch addition attempts.

    Formula

    a) %100*][

    )(AttshoMoveOut

    allFailshoMoveOutCellRACRBranchAddF

    ACR

    ACR

    =

    b) %100*][)(AttshoMoveOutallFailshoMoveOutACRRACRBranchAddF =

    c) %100*][

    ),(AttshoMoveOut

    iFailshoMoveOutseFailureCauCellRACRBranchAddF

    ACR

    ACR

    =

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761836 NEC Corporation: ND-57827-701(E)-01

    d) %100*][),(AttshoMoveOut

    iFailshoMoveOutseFailureCauACRRACRBranchAddF =

    Counters shoMoveOutFail[all] shoMoveOutAtt

    Failure causes same as for measurements per cell. Object a) c) Cell

    b) d) Adjacent cell Unit/Range Percent Remark a) c) These calculations provide the cell related branch addition failure rate. I.e. the

    failure rate belongs to the added cell from all cell relations. b) d) These calculations provide the adjacent cell related branch addition failure

    rate. Calculation of the failure rate per individual cell relation. Remark, the measured object is the cell, which has been added to the active link set.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 37

    3.4 Hard Handover Within UMR2.0, only intra Node B inter-frequency Hard Handovers are considered.

    3.4.1 Outgoing Hard Handover success rate

    Long name a) Outgoing Hard Handover success rate (Intra Node B) b) Intra Node B outgoing Hard Handover success rate (Handover cause)

    Short name a) HHOSR(IntraNB) b) IntraNBHHOSR(HandoverCause)

    Description This KPI provides the ratio between successful outgoing circuit switched hard handover related to the attempted outgoing circuit switched hard handover.

    Formula a) %100*

    ]][1[]][1[)(

    alltthhoAllOutAallucchhoAllOutSIntraNBHHOSR =

    b) %100*]][1[]][1[

    )(itthhoAllOutAiucchhoAllOutS

    useHandoverCaSRIntraNBHHO =

    Counters hhoAllOutSucc[type][all] hhoAllOutAtt[type][all]

    HHO cause: 1,0,0 Load control 2,4,43 Relocation desirable for radio reasons Other other cause

    HHO type: 1 Intra Node B

    Object Cell Unit/Range Percent Remark

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761838 NEC Corporation: ND-57827-701(E)-01

    3.4.2 Outgoing Hard Handover failure rate

    Long name a) Outgoing Hard Handover failure rate (Intra Node B) b) Intra Node B outgoing Hard Handover failure rate (Failure cause)

    Short name a) HHOFR(IntraNB) b) IntraNBHHOFR(FailureCause)

    Description This KPI provides the ratio between unsuccessful outgoing circuit switched hard handover related to the attempted outgoing circuit switched hard handover. Handover failure describes unsuccessful handovers with the reconnection to the originating cell.

    Formula a) %100*

    ]][1[],80][1[)(

    alltthhoAllOutAotherailhhoAllOutFIntraNBHHOFR =

    b) %100*]][1[]][1[)(

    alltthhoAllOutAiailhhoAllOutFseFailureCauFRIntraNBHHO =

    Counters hhoAllOutFail[type][all] hhoAllOutAtt[type][all]

    HHO failure causes: 3,2,0 Configuration unsupported 3,2,1 physical channel failure 3,2,2 incompatible simultaneous reconf. 3,2,3 protocol error 3,2,4 compressed mode runtime error 3,2,5 cell reselection 3,2,6 invalid configuration 3,2,7 configuration incomplete 3,2,8 unsupported measurement NoReply no reply Other other failure cause

    HHO type: 1 Intra Node B

    Object Cell Unit/Range Percent Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 39

    3.4.3 Outgoing Hard Handover drop rate

    Long name Outgoing Hard Handover drop rate (Intra Node B) Short name HHODR(IntraNB) Description This KPI provides the hard handover drop rate.

    Handover drop describes unsuccessful handovers without reconnection to originating cell, i.e. with loss of call.

    Formula %100*

    ]][1[]Re][1[

    )(alltthhoAllOutA

    plyNoailhhoAllOutFIntraNBHHODR =

    Counters hhoAllOutFail[type][all] hhoAllOutAtt[type][all]

    HHO failure causes: 3,2,0 Configuration unsupported 3,2,1 physical channel failure 3,2,2 incompatible simultaneous reconf. 3,2,3 protocol error 3,2,4 compressed mode runtime error 3,2,5 cell reselection 3,2,6 invalid configuration 3,2,7 configuration incomplete 3,2,8 unsupported measurement NoReply no reply Other other failure cause

    HHO type: 1 Intra Node B

    Object Cell Unit/Range Percent Remark

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761840 NEC Corporation: ND-57827-701(E)-01

    3.5 Inter-System (Inter-RAT) Handover

    3.5.1 Relocation Preparation (ACM)

    3.5.1.1 Relocation Preparation failure rate

    Long name a) Relocation Preparation failure rate b) Relocation Preparation failure rate (Relocation Failure cause)

    Short name

    a) RelocPrepFRpACM b) RelocPrepFRpACM(RelocationFailure)

    Description This KPI provides the Relocation Preparation failure rate per adjacent inter RAT cell. Formula

    a) %100*][Reint][ReintPrRe

    alllocAtterRatHoOutalllocFailerRatHoOutepFRpACMloc =

    b) %100*][Reint][ReintFailure)Relocation(PrRe

    alllocAtterRatHoOutilocFailerRatHoOutepFRpACMloc =

    Counters interRatHoOutRelocFail[all] interRatHoOutRelocAtt[all]

    Inter-system relocation failure cause: 2,4,7 TRELOCalloc expiry 2,4,9 Unknown target RNC 2,4,10 relocation cancelled 2,4,29 relocation failure in Target CN or target system 2,4,44 relocation not supported in target system Other other failure cause during relocation preparation

    Object Adjacent GSM Cell Unit/Range Percent Remark These calculations provide the adjacent inter system cell related relocation preparation

    failure rate. I.e. calculation of the failure rate per individual UTRAN to inter system cell relation.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 41

    3.5.2 Outgoing circuit switched Inter-System Handover

    3.5.2.1 Outgoing CS Inter System Handover success rate

    a) Per adjacent inter system cell:

    Long name a) Outgoing CS Inter System Handover success rate b) Outgoing CS Inter System Handover success rate (Handover cause)

    Short name a) ISHOOutCSSRpACM b) ISHOOutCSSRpACM(HandoverCause)

    Description This KPI provides the outgoing circuit switched inter RAT handover success rate per adjacent inter Rat cell.

    Formula a) %100*

    ][int][int

    allAtterRatHoOutallSuccerRatHoOutRpACMISHOOutCSS =

    b) %100*][int][int)(

    iAtterRatHoOutiSuccerRatHoOutuseHandoverCaRpACMISHOOutCSS =

    Counters interRatHoOutSucc[all] interRatHoOutAtt[all]

    Inter-System HHO cause: 2,4,43 Relocation desirable for radio reasons other other cause

    Object Adjacent GSM Cell Unit/Range Percent Remark These calculations provide the adjacent cell related inter system handover success

    rate. I.e. calculation of the success rate per individual UTRAN to inter system cell relation.

    b) Per cell:

    Long name a) Outgoing CS Inter System Handover success rate b) Outgoing CS Inter System Handover success rate (Handover cause)

    Short name a) ISHOOutCSSRpCell b) ISHOOutCSSRpCell(HandoverCause)

    Description This KPI provides the outgoing circuit switched inter RAT handover success rate. Formula

    a) %100*]][5[]][5[

    alltthhoAllOutAallucchhoAllOutSRpCellISHOOutCSS =

    b) %100*]][5[]][5[)(

    itthhoAllOutAiucchhoAllOutSuseHandoverCaRpCellISHOOutCSS =

    Counters hhoAllOutSucc[type][all]

    hhoAllOutAtt[type][all]

    Inter-System HHO cause: 2,4,43 Relocation desirable for radio reasons Other Other cause

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761842 NEC Corporation: ND-57827-701(E)-01

    HHO type: 5 Inter System

    Object Cell Unit/Range Percent Remark

    3.5.2.2 Outgoing CS Inter System Handover failure rate

    a) Per adjacent GSM cell:

    Long name a) Outgoing CS Inter System Handover failure rate b) Outgoing CS Inter System Handover failure rate (Handover Failure cause)

    Short name

    a) ISHOOutCSFRpACM b) ISHOOutCSFRpACM(HandoverFailureCause)

    Description This KPI provides the outgoing circuit switched inter RAT handover failure rate per adjacent inter Rat cell. Handover failure describes unsuccessful handovers with re-connection to originating cell

    Formula a) %100*

    ][int],3,2,1,0[int

    allAtterRatHoOutotherFailerRatHoOutRpACMISHOOutCSF =

    b) %100*][int][int)(

    allAtterRatHoOutiFailerRatHoOutilureCauseHandoverFaRpACMISHOOutCSF =

    Counters interRatHoOutFail[all] interRatHoOutAtt[all]

    Inter-System HHO failure cause: 3,1,0 Configuration unsupported 3,1,1 Physical channel failure 3,1,2 Protocol error 3,1,3 Inter-RAT protocol error NoReply No reply other Other causes

    Object Adjacent GSM Cell Unit/Range Percent Remark These calculations provide the adjacent cell related inter system handover failure rate.

    I.e. calculation of the failure rate per individual UTRAN to inter system cell relation.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 43

    b) Per cell:

    Long name a) Outgoing CS Inter System Handover failure rate b) Outgoing CS Inter System Handover failure rate (Handover Failure cause)

    Short name a) ISHOOutCSFRpCell b) ISHOOutCSFRpCell(HandoverFailureCause)

    Description This KPI provides the outgoing circuit switched inter RAT handover failure rate. Handover failure describes unsuccessful handovers with re-connection to originating cell

    Formula a) %100*

    ]][5[],3,2,1,0][5[

    alltthhoAllOutAotherailhhoAllOutFRpCellISHOOutCSF =

    b) %100*]][5[]][5[)(

    alltthhoAllOutAiailhhoAllOutFilureCauseHandoverFaRpCellISHOOutCSF =

    Counters hhoAllOutFail[type][i]

    hhoAllOutAtt[type][all]

    Inter-System HHO failure cause: 3,1,0 Configuration unsupported 3,1,1 Physical channel failure 3,1,2 Protocol error 3,1,3 Inter-RAT protocol error NoReply No reply other Other causes

    HHO type: 5 Inter System

    Object Cell Unit/Range Percent Remark

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761844 NEC Corporation: ND-57827-701(E)-01

    3.5.2.3 Outgoing CS Inter System Handover drop rate

    a) Per adjacent GSM cell:

    Long name Outgoing CS Inter System Handover drop rate Short name ISHOOutCSDRpACM Description This KPI provides the outgoing circuit switched inter RAT handover drop rate per

    adjacent inter Rat cell. Handover drop describes unsuccessful handovers without re-connection to originating cell, i.e. with loss of call.

    Formula %100*

    ][int]Re[int

    allAtterRatHoOutplyNoFailerRatHoOutRpACMISHOOutCSD =

    Counters interRatHoOutFail[i] interRatHoOutAtt[all]

    Inter-System HHO failure cause: 3,1,0 Configuration unsupported 3,1,1 Physical channel failure 3,1,2 Protocol error 3,1,3 Inter-RAT protocol error NoReply No reply other Other causes

    Object Adjacent GSM Cell Unit/Range Percent Remark This calculation provides the adjacent cell related inter system handover drop rate. I.e.

    calculation of the drop rate per individual UTRAN to inter system cell relation.

    b) Per cell:

    Long name Outgoing CS Inter System Handover drop rate Short name ISHOOutCSDRpCell Description This KPI provides the outgoing circuit switched inter RAT handover drop rate.

    Handover drop describes unsuccessful handovers without re-connection to originating cell, i.e. with loss of call.

    Formula %100*

    ]][5[]Re][5[

    alltthhoAllOutAplyNoailhhoAllOutFRpCellISHOOutCSD =

    Counters hhoAllOutFail[type][i] hhoAllOutAtt[type][all]

    Inter-System HHO failure cause: 3,1,0 Configuration unsupported 3,1,1 Physical channel failure 3,1,2 Protocol error 3,1,3 Inter-RAT protocol error NoReply No reply other Other causes

    HHO type: 5 Inter System

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 45

    Object Cell Unit/Range Percent Remark

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761846 NEC Corporation: ND-57827-701(E)-01

    4 Quality Indicators

    4.1 Principle High-level quality indicators are used for the detection of trends in quality and quantity of the UTRAN. The scope for these indicators may vary, depending on the observed region. In all quality indications depicted below the procedure related success rate is defined according the generic indicator below:

    100%*,

    ,,

    =

    NE iNEi

    NE iNEi

    NE iNEi

    C

    BAIndicator

    4.2 Call establishment quality indicator

    Long name Call establishment quality indicator Short name CSQI Description This KPI gives an overall quality indicator for call establishments. Formula

    %100*][

    ][*

    ]90[

    ]90[

    =

    CellalltrabEstabAt

    CellallccrabEstabSu

    CelltrrcEstabAt

    CellccrrcEstabSu

    CSQI

    Counters CSSR(AccessProbability) (see 2.1.1) Object UTRAN / RNC / NodeB Unit/Range 0% (worst) ..100% (best) Remark Elementary object is depending on the scope of the summarizations

    4.3 Branch Addition quality indicator

    Long name Branch addition quality indicator Short name BranchAddQI Description This KPI gives an overall quality indicator for soft handover. Formula

    %100*

    ])[][

    ][(])[][

    ][(

    allrRncAttshoAddInteallaRncAttshoAddIntr

    allaNodeBAttshoAddIntrCell

    allrRncSuccshoAddInteallaRncSuccshoAddIntr

    allaNodeBSuccshoAddIntrCell

    IBranchAddQ

    +

    +

    +

    +

    =

    Counters BranchAddSR (see 3.3.1) Object UTRAN / RNC / NodeB

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 47

    Unit/Range 0% (worst) ..100% (best) Remark Elementary object is depending on the scope of the summarizations

    4.4 Hard handover quality indicator

    Long name Hard handover quality indicator Short name HHOQI(IntraNB) Description This KPI gives an overall quality indicator for hard handover. Formula

    %100*]][1[

    ]][1[)(

    =

    CellalltthhoAllOutA

    CellallucchhoAllOutS

    IntraNBHHOQI

    Counters HHOSR (see 3.4.1) Object UTRAN / RNC / NodeB Unit/Range 0% (worst) ..100% (best) Remark Elementary object is depending on the scope of the summarizations.

    Only Intra Node B handover supported within UMR2.0.

    4.5 Inter-System handover quality indicator

    Long name Inter-System handover quality indicator Short name ISHOQI Description This KPI gives an overall quality indicator for inter-System handover. Formula

    %100*]][5[

    ]][5[

    =

    CellalltthhoAllOutA

    CellallucchhoAllOutS

    ISHOQI

    Counters ISHOOutCSSRpCell (see 3.5.2.1) Object UTRAN / RNC / NodeB Unit/Range 0% (worst) ..100% (best) Remark Elementary object is depending on the scope of the summarizations

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761848 NEC Corporation: ND-57827-701(E)-01

    5 QuaNTIty Indicators

    5.1 RRC State Transitions

    5.1.1 Number of successful state transitions

    Long name a) Number of successful state transitions from Cell_DCH state (Target state) b) Number of successful state transitions from Cell_FACH state (Target state) c) Number of successful state transitions from Cell_PCH state (Target state) d) Number of successful state transitions from URA_PCH state (Target state)

    Short name a) STSuccfromCell_DCH(Target) b) STSuccfromCell_FACH(Target) c) STSuccfromCell_PCH[Target] d) STSuccfromURA_PCH[Target]

    Description This indicator will give you the number of successful state transitions from origin state to target state.

    Formula a)

    ]][1[]1[)1(_

    allellDchFailtransFromCellDchAtttransFromCDCHCellSTSuccfrom =

    b) ]][3,2,0[

    ]3,2,0[]3,2,0[_alllellFachFaitransFromC

    ellFachAtttransFromCFACHCellSTSuccfrom =

    c) ]][1[

    ]1[]1[_allellPchFailtransFromC

    ellPchAtttransFromCPCHCellSTSuccfrom =

    d) ]][1[

    ]1[]1[_allraPchFailtransFromU

    raPchAtttransFromUPCHURASTSuccfrom =

    Counters transFrom****Att[Target] transFrom****Fail[Target][all] Target states: 0 CELL_DCH 1 CELL_FACH 2 CELL_PCH 3 URA_PCH State transition failure causes: See 2.3.1

    Object Cell RNC - for transitions from URA_PCH state

    Unit/Range None Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 49

    5.1.2 Number of state transitions to Idle mode This KPI corresponds to the RRC release. See measurement type description in appendix: rrcRelDcch[all] and rrcRelCcch[all]

    5.2 Soft Handover

    5.2.1 Soft Handover rate

    Long name Soft handover rate Short name SHORate(RLN) Description This indicator will give you the percentage rate of UEs with 1, 2 or 3 radio links per

    active link set size. Formula

    %100*][][)(

    allizeveLinkSetSuesPerActiRLNizeveLinkSetSuesPerActiRLNSHORate =

    Counters uesPerActiveLinkSetSize[RLN] Radio Link Numbers: 0 Active Link set size =1 1 Active Link set size = 2 2 Active Link set size = 3

    Object Cell Unit/Range Percent Remark Since in UMR2.0 the periodicity is 5 minutes the actual value of the number of active

    links per link set size are considered this calculation gives only a rough indication of the soft handover rate.

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761850 NEC Corporation: ND-57827-701(E)-01

    5.3 Relocations

    5.3.1 Number of outgoing relocations See measurement type description in appendix: relocOutAtt[all]

    5.3.2 Number of incoming relocations See measurement type description in appendix: relocIncAtt[all]

    5.3.3 Outgoing Relocation per Call rate

    Long name Outgoing Relocation per call rate Short name RelocperCallRate Description This KPI describes the ratio of successful outgoing relocations related to the number of

    established calls. Formula

    %100*][

    ][Re

    =

    CellallccrabEstabSu

    allccrelocOutSuRatelocperCall

    Counters relocOutSucc[all] rabEstabSucc[all]

    Relocation causes: 2,4,41 Resource optimisation relocation 2,4,43 Relocation desirable for radio reasons 2,4,45 Directed Retry other other causes

    Object RNC Unit/Range Percent Remark In a normal sequence first the RAB will be established and later on the outgoing

    relocation may occur. Thus, it may occur that the RAB Establishment may be measured within an earlier GP than the outgoing relocation procedure is measured. This applies especially in case of PS calls. The mean number of outgoing relocations per call should therefore be considered in a greater period, e.g. per day.

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 51

    5.4 Hard Handover

    5.4.1 Outgoing Hard Handover per call rate

    Long name Outgoing Hard Handover per call rate Short name HHOperCallRate(NodeB) Description This indicator gives the ratio between Intra-Node B hard handovers related to the

    number of Call Setups. Formula

    =

    Cell

    Cell

    allccrabEstabSu

    allucchhoAllOutSNodeBRateHHOperCall

    ][

    ]][1[

    )(

    Counters hhoAllOutSucc[type][all] rabEstabSucc[all]

    HHO cause: 1,0,0 Load control 2,4,43 Relocation desirable for radio reasons Other other cause

    HHO type: 1 Intra Node B

    Object RNC Unit/Range None Remark In a normal sequence first the RAB will be established and later on the outgoing hard

    handover may occur. Thus, it may occur that the RAB establishment may be measured within an earlier GP than the outgoing hard handover procedure is measured. This applies especially in case of PS calls. The mean number of outgoing hard handover per call should therefore be considered in a greater period, e.g. per day. In addition it should be considered that by a previous Soft Handover the originating cell of the hard handover may not be the cell where the RAB establishment has been performed and measured. Therefore the Outgoing Hard Handover per call rate should is related to the RNC instead to a cell.

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761852 NEC Corporation: ND-57827-701(E)-01

    5.5 Inter System Handover

    5.5.1 Outgoing CS Inter System Handover per call rate

    In a normal sequence first the RAB will be established and later on the inter system hard handover may occur. Thus, it may occur that the RAB establishment may be measured within an earlier GP than the outgoing inter system handover procedure is measured. This applies especially in case of PS calls. The mean number of outgoing hard handover per call should therefore be considered in a greater period, e.g. per day. In addition it should be considered that by a previous Soft Handover the originating cell of the hard handover may not be the cell where the RAB establishment has been performed and measured. Therefore the Outgoing Inter System Handover per call rate may be related better to the RNC instead to a cell.

    Long name Outgoing CS Inter System Handover per call rate Short name ISHOperCallRate Description This indicator gives the ratio between inter system handovers related to the number of

    Call Setups. Formula

    =

    Cell

    Cell

    allccrabEstabSu

    allucchhoAllOutSlRateISHOperCal

    ][

    ]][5[

    Counters hhoAllOutSucc[type][all] rabEstabSucc[all]

    HHO cause: 2,4,43 Relocation desirable for radio reasons Other other cause

    HHO type: 5 Inter System

    Object RNC Unit/Range None Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 53

    6 UtiliZation

    6.1 RNC Load Report

    6.1.1 RNC Processor Load See measurement type description in appendix: rncUsageRatio

    6.1.2 DHT usage See measurement type description in appendix: dhtUsage

    6.1.3 DHT allocation success rate

    Long name DHT allocation success rate Short name DHTAllocSR Description This indicator provides the DHT allocation success ratio. Formula

    %100*tdhtAllocAtccdhtAllocSuDHTAllocSR =

    Counters dhtAllocSucc dhtAllocAtt

    Object RNC Unit/Range Percent Remark

    6.1.4 PRLC usage See measurement type description in appendix: prlcUsage

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761854 NEC Corporation: ND-57827-701(E)-01

    6.1.5 PRLC allocation success rate

    Long name PRLC allocation success rate Short name PRLCAllocSR Description This indicator provides the PRLC allocation success ratio. Formula

    %100*ttprlcAllocAuccprlcAllocSRPRLCAllocS =

    Counters prlcAllocSucc prlcAllocAtt

    Object RNC Unit/Range Percent Remark

    6.2 Node B Load Report

    6.2.1 Node B usage rate See measurement type description in appendix: cpUsageRatio for Node B PF1 and ccProcessorLoad for Node B PF2.

    6.2.2 Base Band usage rate See measurement type description in appendix: bbUsageRatio

    6.2.3 Rest of call capacity See measurement type description in appendix: restOfCallCapacity

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 55

    6.3 Cell Load Report

    6.3.1 Cell Utilisation

    6.3.1.1 Code usage rate

    Long name Code usage rate Short name CodeUsageRate Description This indicator gives the ratio between the sum of used codes per SF related to the total

    number of usable SF. Formula

    %100*512

    128*]0[64*]1[32*]2[16*]3[

    8*]4[4*]5[2*]6[1*]7[

    duuCodesUseduuCodesUseduuCodesUseduuCodesUseduuCodesUseduuCodesUseduuCodesUseduuCodesUse

    ateCodeUsageR+

    ++

    ++

    ++

    =

    Counters uuCodesUsed [all]

    Spreading factor parameters: 0 SF4 1 SF8 2 SF16 3 SF32 4 SF64 5 SF128 6 SF256 7 SF512

    Object Cell Unit/Range Percent Remark The indicated code usage rate applies only for DL. Remark also, that SF4 is not

    supported in UMR2.0. Since in UMR2.0 the periodicity is 5 minutes the actual value of the number of used codes per SF are considered this calculation gives only a rough indication of the code usage rate.

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761856 NEC Corporation: ND-57827-701(E)-01

    6.3.2 Cell load related Radio Measurements

    6.3.2.1 Transmitted Carrier power

    Long name Cell load per Transmitted Carrier power Short name TxCarrierPwr(MMM) Description This indicator provides the cell load related to the transmitted carrier power. Formula ][)( MMMrrierPwruuTransmCaMMMwrTxCarrierP = Counters uuTransmCarrierPwr[MMM]

    MMM: 0 Mean value 1 Minimum value 2 Maximum value

    Object Cell Unit/Range Percent Remark The measured value already provides a percentage value.

    6.3.2.2 Received Total Wide Band Power

    Long name Cell load per Received Total Wide Band Power Short name RxTotalWBPwr(MMM) Description This indicator provides the cell load related to the received total wide band power. Formula

    %100*621

    ][Re)( MMMrcTotalWbPwuuMMMwrRxTotalWBP =

    Counters uuRecTotalWbPwr[MMM]

    MMM: 0 Mean value 1 Minimum value 2 Maximum value

    Object Cell Unit/Range Percent Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 57

    6.4 Radio interface

    6.4.1 Common Channel Load Reports For load reports of common channels see measurement type description in appendix: pchUsageRate pchDiscardRate fachUsageRate fachDiscardRate prachUsageRate sccpchUsageRatio numberOfReceivedPreambles

    6.4.2 Code allocation success rate

    Long name a) Code allocation success rate b) Code allocation success rate(SF)

    Short name a) CodeAllocSR b) CodeAllocSR(SF)

    Description This indicator provides the code allocation success ratio per spreading factor. Formula

    a) %100*][Re][Re

    allqAttuuCodeallqSuccuuCodeRCodeAllocS =

    b) %100*][Re][Re

    )(allqAttuuCodeSFqSuccuuCodeSFRCodeAllocS =

    Counters uuCodeReqAtt[all] uuCodeReqSucc[all]

    Spreading factor parameters: 0 SF4 1 SF8 2 SF16 3 SF32 4 SF64 5 SF128 6 SF256 7 SF512

    Object Cell Unit/Range Percent Remark The indicated code usage rate applies only for DL. Remark also, that SF4 is not

    supported in UMR2.0.

  • Key Performance Indicators Performance Measurement System

    Siemens AG: A50016-G5000-D528-1-761858 NEC Corporation: ND-57827-701(E)-01

    7 Transport Network Layer

    7.1 ATM-Layer on RNC side

    7.1.1 STM-1 Transmission usage rate

    Long name STM-1 transmission usage rate Short name STM1TxUsageRate Description This indicator provides the ratio between transmitted cells related to maximum number

    of cell transmissions. Formula

    %100**

    8*53/155/max

    1GPsMbit

    ngCellslineOutgoilinellsOutgoingce

    ngCellslineOutgoieTxUsageRatSTM ==

    Counters lineOutgoingCells

    Object STML Unit/Range Percent Remark

    7.1.2 STM-1 Receive usage rate

    Long name STM-1 receive usage rate Short name STM1RxUsageRate Description This indicator provides the ratio between received cells related to maximum number of

    received cells. Formula

    %100**

    8*53/155

    min/minmax

    min1

    GPsMbitgCellslineInco

    linegcellsIncogCellslineIncoeRxUsageRatSTM ==

    Counters lineIncomingCells

    Object STML Unit/Range Percent Remark

  • Performance Measurement Key Performance IndicatorsSystem

    Siemens AG: A50016-G5000-D528-1-7618NEC Corporation: ND-57827-701(E)-01 5