1
E-HOUSE (SWITCHBOARD- AND CONTROL ROOM)
Halvorsen E-House’s can be designed for permanent or
temporary installation.
Benefits:
Flexible internal layouts to suit your requirements
Extremely compact design
Good service access
Lifting approval according to DNV 2.7.1, DNV
2.7-3 or NORSOK R-002
ISO corners and forklift pockets
Approved for EX Zone 1, 2 and safe area
Surface treatment Norsok M501 System 1
Noise and Fire isolation
Over pressured
High quality personal door(s) and escape hatch
High quality fixtures and interior design.
Tie-in compartment for rig interface and cables
Power supply 230, 400-440-480-660-690VAC
50/60Hz
Fire & Gas detection system with signals to CCREmergency Power Distribution modul
(42ft) for Permanent installation, Zone 1
II2G
2
Power Distribution Module (e-house)
Halvorsen E-House’s can be designed for permanent or
temporary installation.
Benefits:
Flexible internal layouts to suit your requirements
Extremely compact design
Good service access
Lifting approval according to DNV 2.7.1, DNV
2.7-3 or NORSOK R-002
ISO corners and forklift pockets
Approved for EX Zone 1, 2 and safe area
Surface treatment Norsok M501 System 1
Noise and Fire isolation
Over pressured
High quality personal door(s) and escape hatch
High quality fixtures and interior design.
Tie-in compartment for rig interface and cables
Power supply 230, 400-440-480-660-690VAC
50/60Hz
Fire & Gas detection system with signals to CCRPower Distribution modul
(55ft) for drilling plant, Zone 2
II3G
3
OFFICE/ LABORATORY
Halvorsen office’s can be designed for permanent or
temporary installation.
Benefits:
Flexible internal layouts to suit your requirements
Extremely compact design
Good service access
Lifting approval according to DNV 2.7.1, DNV
2.7-3 or NORSOK R-002
ISO corners and forklift pockets
Approved for EX Zone 1, 2 and safe area
Surface treatment Norsok M501 System 1
Noise and Fire isolation
Over pressured
High quality personal door(s) and escape hatch
High quality fixtures and interior design.
Tie-in compartment for rig interface and cables
Power supply 230, 400-440-480-660-690VAC
50/60Hz
Fire & Gas detection system with signals to CCR
Control and store module (15ft)
II2G
4
WORKSHOP
Halvorsen container’s can be designed for permanent or
temporary installation.
Benefits:
Flexible internal layouts to suit your requirements
Extremely compact design
Good service access
Lifting approval according to DNV 2.7.1, DNV
2.7-3 or NORSOK R-002
ISO corners and forklift pockets
Approved for EX Zone 1, 2 and safe area
Surface treatment Norsok M501 System 1
Noise and Fire isolation
Over pressured
High quality personal door(s) and escape hatch
High quality fixtures and interior design.
Tie-in compartment for rig interface and cables
Control/Distribution board
Air conditioner
Power supply 230, 400-440-480-660-690VAC
50/60Hz
Fire & Gas detection system with signals to CCR
Workshop container with AC for
operation in Abu Dhabi desert (-20 to +55°C)
II2G
5
DIESEL POWER PUMP UNITS
Halvorsen diesel unit’s can be designed for permanent or
temporary installation.
Benefits:
Flexible internal layouts to suit your requirements
Extremely compact design
Good service access
Lifting approval according to DNV 2.7.1, DNV
2.7-3 or NORSOK R-002
ISO corners and forklift pockets
Approved for EX Zone 2 and safe area
Surface treatment Norsok M501 System 1
Noise and Fire isolation
Over pressured
High quality door(s)
Tie-in compartment for rig interface and cables
Power supply 230 VAC 50/60Hz
Fire & Gas detection system with signals to CCR
Diesel Hydraulic power pack module(s)
for drilling plant, Zone 2
II3G
6
GENERATOR
Halvorsen generator’s can be designed for permanent or
temporary installation.
Benefits:
Flexible internal layouts to suit your requirements
Extremely compact design
Good service access
Lifting approval according to DNV 2.7.1, DNV
2.7-3 or NORSOK R-002
ISO corners and forklift pockets
Approved for EX Zone 2 and safe area
Surface treatment Norsok M501 System 1
Noise and Fire isolation
Over pressured
High quality door(s)
Tie-in compartment for rig interface and cables
Power
- 230 VAC 50/60Hz230 to 690 VAC
- 50/60 Hz
- ~3000 kVA / 2400 kW
Fire & Gas detection system with signals to CCR1360 kW Generator module(s)
for temporary installation, Zone 2
II3G
7
TRANSFORMER
Halvorsen transformer’s can be designed for permanent or
temporary installation.
Benefits:
Flexible internal layouts to suit your requirements
Extremely compact design
Good service access
Lifting approval according to DNV 2.7.1, DNV
2.7-3 or NORSOK R-002
ISO corners and forklift pockets
Approved for EX Zone 1, 2 and safe area
Surface treatment Norsok M501 System 1
Noise and Fire isolation
Over pressured
High quality door(s)
Tie-in compartment for rig interface and cables
Power
- ~36 000 V
- 50/60 Hz
- ~10 000 kVA
Fire & Gas detection system with signals to CCR690 / 6600V, 2000kVA Transformer module
(12ft) for temporary installation, Zone 2
II3G
8
ELECTRIC PUMP UNITS
Halvorsen Electrical unit’s can be designed for permanent or
temporary installation.
Benefits:
Flexible internal layouts to suit your requirements
Extremely compact design
Good service access
Lifting approval according to DNV 2.7.1, DNV
2.7-3 or NORSOK R-002
Approved for EX Zone 1, 2 and safe area
High quality door(s)
Tie-in compartment for rig interface and cables
Power 230-400-440-480-660-690 VAC 50/60 Hz
Electric HP water pump module
Norsok Z-015, Zone 1
II3G
9
OTHER / CUSTOM DESIGN
Halvorsen can special designed all type of machines and
equipment for permanent or temporary installation.
Examples:
Heater tank
Fire Extinguishing system
Tank
Air dryer
Injection system
Mixing skid
SALE AND/OR RENTAL
Halvorsen system for Air Dehumidifying
DESCRIPTION:
The DDU (Desiccant Dehumidifier Unit) are built and documented according to NorsokZ-015.
Approved for operation in ATEX Zone 2 (II3G)
Gas detector in the inlet for shutdown if gas leakage
Fire damper in the inlet to secure unit if gas leakage
Dehumidifies to low dew-point
Temperature and humidity set point controls can be preset to specific conditions
Mounted in solid lifting SS316 Stainless Steel frame according to DNV 2.7-1
Wheels for ease moving on deck
Under 2m² in foot print
11II3G Ex nA nC de mb [ia/ib] IIC T3
Halvorsen system for Land to Ship Power
12
Description:
The SMART SPM (Ship Power Module) consists of 2 (two) Variable Frequency Drives (VFD) and 2 (two) transformers installed in a 20” container.
The advantage of using this type of converter as temporary power supply or test supply is that one unit can be used to supply different voltages and frequencies
The SMART SPM has separate input and output breakers and are ready for all input voltages between 380 to 500V or 690V and 50 or 60Hz and output voltages and frequencies between 400V to 690V and 50 or 60Hz
The SMART SPM can also be setup with other input/output voltages and frequencies than listed in technical data.
Power cable units also available
All according to: NEK IEC PAS 80005-3