Using CDF and D0 to Understand the Tevatron
-
Upload
lillian-cole -
Category
Documents
-
view
22 -
download
2
description
Transcript of Using CDF and D0 to Understand the Tevatron
Using CDF and D0 to Understand the TevatronUsing CDF and D0 to Understand the Tevatron
Jean SlaughterDOE ReviewJuly 21, 2003
Using CDF and D0 Information – July 2003 -Slaughter 2
Three Ways to Use CDF and D0 DataThree Ways to Use CDF and D0 Data
Computed versus measured luminosity Cross check on instrumentation, *
Size of the luminous region versus z Information on lattice at interaction points,
emittances Use silicon vertex detectors for very accurate
determination Stan Lai, William Trischuk, U. of Toronto, et al Juan Estrada, Avdhesh Chandra, D0, et al
z of proton and anti-proton bunches Time of flight and Central Tracking Chamber in CDF Mathew Jones, U. of Penn.
Using CDF and D0 Information – July 2003 -Slaughter 3
Calculated LuminosityCalculated Luminosity
. (1)
N = numbers of protons, anti-protons per bunch (109) B = number of bunches (36) f = revolution frequency (47.7 KHz)rr = relativistic factor, 1045 = interaction point (cm, assumed equal in x
and y).H = hourglass factor, function of l, bunch length,
*
= transverse emittances
*
*
5
2
610
l
yppxpp
rrpp HNfBN
L
Using CDF and D0 Information – July 2003 -Slaughter 4
Measured LuminosityMeasured Luminosity
CDF – CLC (Cherenkov Luminosity Counter)
D0 – system of scintillation counters
Accurate measurement crucial to experiments for cross section determination Goal is 5% systematic error, < 1% statistical error
Systematic difference between D0 and CDF Ratio is linear with luminosity 10% difference at 4.0 1031
Using CDF and D0 Information – July 2003 -Slaughter 5
Ratio of D0 to CDF LuminosityRatio of D0 to CDF Luminosity
Using CDF and D0 Information – July 2003 -Slaughter 6
Components to Calculated LuminosityComponents to Calculated Luminosity
Number of protons, anti-protons FBI (Fast Bunch Integrator) or SBD (Sampled Bunch
Display)
Transverse emittances SyncLite
Bunch lengths SBD
Using CDF and D0 Information – July 2003 -Slaughter 7
D0 Measured Luminosity versus Calculated D0 Measured Luminosity versus Calculated LuminosityLuminosity
Using CDF and D0 Information – July 2003 -Slaughter 8
CDF measured Luminosity versus Calculated CDF measured Luminosity versus Calculated LuminosityLuminosity
Using CDF and D0 Information – July 2003 -Slaughter 9
CDF RatioCDF Ratio
Using CDF and D0 Information – July 2003 -Slaughter 10
D0 RatioD0 Ratio
Using CDF and D0 Information – July 2003 -Slaughter 11
Use Silicon Detectors for Size of the Luminous Use Silicon Detectors for Size of the Luminous RegionRegion
*
20*2 )(
zz
eff
pbarp
pbarpeff
*=0.35 cm , =2E-7 cm*=0.40 cm , =2E-7 cm*=0.35 cm , =3E-7 cm
.
Nominal value has * = 0.35 cm.
Two methods 1. vertices 2. distance of closest approach for 2 track pairs
Using CDF and D0 Information – July 2003 -Slaughter 12
Given a distribution of vertexes (xi,yi ,zi) then observed width is:
σbeam = width of the luminous region
σvertex = error in the vertex position
Problem - estimate for σvertex is smaller than the real error in the vertex, so find k from the data doing a linear fit
Method 1 - Use VertexesMethod 1 - Use Vertexes
222vertexbeamobs
222vertexbeamobs k
Using CDF and D0 Information – July 2003 -Slaughter 13
CDF resultsCDF results
Using CDF and D0 Information – July 2003 -Slaughter 14
Using CDF and D0 Information – July 2003 -Slaughter 15
Results for X – D0Results for X – D0
Stores:
1. 2312
2. 2315
3. 2341
4. 2420
5. 2507
6. 2523
7. 2540
store store
store
emittance z at minimum size
z (cm)
sigma
Using CDF and D0 Information – July 2003 -Slaughter 16
Results for Y – D0Results for Y – D0
Stores:
1. 2312
2. 2315
3. 2341
4. 2420
5. 2507
6. 2523
7. 2540
store
store
store
z (cm)
sig
ma
emit
tanc
e
Z of minimum
beta*
Using CDF and D0 Information – July 2003 -Slaughter 17
Comparing D0 pseudo-emittance with Tevatron Comparing D0 pseudo-emittance with Tevatron measurementsmeasurements
1.60E-07
1.80E-07
2.00E-07
2.20E-07
2.40E-07
2.60E-07
2.80E-07
3.00E-07
0 2 4 6 8
epsi
lon
(cm
)
Measured at TevatronUsing vertexes at DØ
store store
= (p pbar)/(p+ pbar),
p p
p pbar are average over h and v for p and pbar
Using CDF and D0 Information – July 2003 -Slaughter 18
Method 2 - Track Pairs Method 2 - Track Pairs
Use distance of closest approach (dca) parameter for pairs of tracks
This assumes a circular beam. If the beam is not circular the relation is a little more complicated. Do has done it both ways.
If you include uncorrelated measurement errors for this tracks, the equation does not change. The error terms cancel in the formula above.
)cos(
)sin()cos(
212
21
F
iii
dd
xyd
Using CDF and D0 Information – July 2003 -Slaughter 19
Distance of Closest Approach PlotsDistance of Closest Approach Plots
dca
Z (cm)
phi
dca
beam
siz
e (c
m)
Using CDF and D0 Information – July 2003 -Slaughter 20
Comparing Results – Beam PositionsComparing Results – Beam Positions
The beam position is the same, when measured with the two methods(vertexes in black and tracks in blue). All scales in cm.
z (cm) z (cm)
x position y position
Using CDF and D0 Information – July 2003 -Slaughter 21
Comparing Results- Sigma versus ZComparing Results- Sigma versus Z
Vertex method gives consistently a beam that is 3-5 um larger in width and with less curvature (larger *). Great cross check on systematics. Under investigation.
(vertexes in black and tracks in blue) All scales in cm.
Using CDF and D0 Information – July 2003 -Slaughter 22
SummarySummary
Comparison of measured and calculated luminosities agree within the erros Work to reduce the errors on each element in
calculated luminosity
Size of luminous regions Interplay between understanding experiment
tracking and understanding the Tevatron lattice and emittances
Current formula is simplistic Adding dN/dz, (the number of vertices as a function
of z) will help Need to revive the work on the length of p and pbar
bunches using the CDF time-of-flight and COT tracking