User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard...

12
1 Experience In Motion Installation Operation Maintenance RG Series Standard Actuator FCD AXENIM0122-00 12/09 USER INSTRUCTIONS

Transcript of User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard...

Page 1: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

1

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

Experience In Motion

Installation Operation

Maintenance

RG Series Standard ActuatorFCD AXENIM0122-00 12/09

USER INSTRUCTIONS

Page 2: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

2

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

1 Using Flowserve Valves, Actuators and Acces-sories Correctly

1.1 General usage

Thefollowinginstructionsaredesignedtoassistinunpacking,installingandperformingmaintenanceasrequiredonFLOWSERVEproducts.Productus-ersandmaintenancepersonnelshouldthoroughlyreviewthisbulletinpriortoinstalling,operatingorperforminganymaintenance.

InmostcasesFLOWSERVEvalves,actuatorsandaccessoriesaredesignedforspecificapplicationswithregardtomedium,pressureandtemperature.Forthisreasontheyshouldnotbeusedinotherap-plicationswithoutfirstcontactingthemanufacturer.

1.2 Terms concerning safety

The safety terms DANGER, WARNING, CAUTIONandNOTEareusedintheseinstructionstohighlightparticulardangersand/ortoprovideadditionalinfor-mationonaspectsthatmaynotbereadilyapparent.

DANGER: indicates that death, severe personal injury and/or substantial property damage will occur if proper precautions are not taken.

WARNING: indicates that death, severe personal injury and/or substantial property damage can occur if proper precautions are not taken.

CAUTION:indicates that minor personal injury and/or property damage can occur if proper precautions are not taken.

NOTE: indicates and provides additional technical information, which may not be very obvious even to qualified personnel.

Compliance with other, not particularly emphasisednotes,withregardtotransport,assembly,operationandmaintenanceandwithregardtotechnicaldocumentation(e.g.intheoperatinginstruction,productdocumentationorontheproductitself)isessential,inordertoavoidfaults,whichinthemselvesmightdirectlyorindirectlycauseseverepersonalinjuryorpropertydamage.

1.3 Protective clothing

FLOWSERVE products are often used in problematicapplications(e.g.extremelyhighpressures,dangerous,toxicorcorrosivemediums).Inparticularvalveswithbellows seals point to such applications. When per-formingservice,inspectionorrepairoperationsalwaysensure,thatthevalveandactuatoraredepressurisedandthatthevalvehasbeencleanedandisfreefromharmfulsubstances. In such casespayparticular attention topersonalprotection(protectiveclothing,gloves,glassesetc.).

1.4 Qualified personnel

Qualifiedpersonnelarepeoplewho,onaccountoftheirtraining,experienceandinstructionandtheirknowledgeofrelevantstandards,specifications,accidentpreventionregulationsandoperatingconditions,havebeenauthor-isedbythoseresponsibleforthesafetyoftheplanttoperformthenecessaryworkandwhocanrecogniseandavoidpossibledangers.

1.5 Installation

DANGER: Before installation check the order-no., serial-no. and/or the tag-no. to ensure that the valve/actuator is correct for the intended application.

Donotinsulateextensionsthatareprovidedforhotorcoldservices.

Pipelinesmustbecorrectlyalignedtoensurethatthevalveisnotfittedundertension.

Fireprotectionmustbeprovidedbytheuser.

1.6 Spare parts

UseonlyFLOWSERVEoriginalspareparts.FLOWSERVEcannotacceptresponsibilityforanydamagesthatoc-curfromusingsparepartsorfasteningmaterialsfromothermanufactures.IfFLOWSERVEproducts(especiallysealingmaterials)havebeenonstoreforlongerperiodschecktheseforcorrosionordeteriorationbeforeusingtheseproducts.FireprotectionforFLOWSERVEproductsmustbeprovidedbytheenduser.

STOP!

INDEX

1 Using Flowserve Valves, Actuators and Ac-cessories Correctly

2 Installation3 Travel Stop Adjustments4 Maintenance Instructions5 Field Conversion from Fail CW to Fail CCW6 Torque Shaft7 Long Term Storage

Page 3: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

3

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

1.7 Service / repair

To avoid possible injury to personnel or damage toproducts, safety terms must be strictly adhered to.Modifying thisproduct,substitutingnonfactoryparts,orusingmaintenanceproceduresother thanoutlinedinthisinstructioncoulddrasticallyaffectperformanceandbehazardoustopersonnelandequipment,andmayvoid existing warranties. Between actuator and valvethere are moving parts. To avoid injury FLOWSERVEprovides pinch-point-protection in the form of coverplates,especiallywhereside-mountedpositionersarefitted.Iftheseplatesareremovedforinspection,serviceorrepairspecialattentionisrequired.Aftercompletingworkthecoverplatesmustberefitted.

Apartfromtheoperatinginstructionsandtheobligatoryaccident prevention directives valid in the country ofuse, all recognised regulations for safety and goodengineeringpracticesmustbefollowed.

WARNING: Before products are returned to FLOWSERVE for repair or service FLOWSERVE must be provided with a certificate which confirms that the product has been decontaminated and is clean. FLOWSERVE will not accept deliveries if a certificate has not been pro-vided (a form can be obtained from FLOWSERVE).

1.8 Storage

InmostcasesFLOWSERVEproductsaremanufacturedfromstainlesssteel.Productsnotmanufacturedfromstainlesssteelareprovidedwithanepoxyresincoating.ThismeansthatFLOWSERVEproductsarewellprotectedfrom corrosion. Nevertheless FLOWSERVE productsmustbestoredadequatelyinaclean,dryenvironment.Plastic caps are fitted to protect the flange faces toprevent the ingress of foreign materials. These capsshouldnotberemoveduntilthevalveisactuallymountedintothesystem.

1.9 Valve and actuator variations

Theseinstructionscannotclaimtocoveralldetailsofall possible product variations, nor can they provideinformationforeverypossibleexampleofinstallation,operation or maintenance. This means that theinstructions normally include only the directions tobe followed by qualified personal where the productisbeingused for isdefinedpurpose. If thereareanyuncertaintiesinthisrespectparticularlyintheeventofmissingproduct-relatedinformation,clarificationmustbeobtainedviatheappropriateFLOWSERVEsalesoffice.

1.10 Unpacking

Each delivery includes a packing slip. Whenunpacking,checkalldeliveredvalvesandaccessoriesusingthispackingslip.

Reporttransportdamagetothecarrierimmediately.

In case of discrepancies, contact your nearestFLOWSERVElocation.

STOP!

Page 4: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

4

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

Introduction TheRGSeriesisafullymodulardesign,scotch-yokeac-

tuator;withtorquerangefrom2000Nmto250,000Nm(2,800 in-Lbs to 2.2 M in-Lbs) in eight models, RG1through RG8, with maximum actuator torque andmountingbaseincompliancewithISO5211.

TheRGseriesSpringReturnActuators,incontrastwithR-series,usePull-to-Compressthespringdesign.

2 Installation

2.1 All actuators are factory lubricated for life, but stillshouldbeprotected fromtheelementsandstored in-doorsuntilreadyforuse.Theportsoftheactuatorarepluggedassupplied from the factory. If actuatorsarestoredforalongperiodoftimepriortoinstallation,fol-lowtheLongTermStorageinstructions.

2.2 Prior to assembly, manually open and close valve (ifpossible), to ensure freeness of operation. Be sure,valveandAutomaxactuatorrotateinthesamedirectionandareinthesameposition(i.e.,valveclosed,actuatorclosed).

2.3 Check the mounting surfaces, the stem adaptor andthebrackettoassureproperfit.Securethevalveintheclosedpositionwiththestemvertical.Boltthebracketto the valve and place the stem adaptor on the valvestem.Positiontheactuatoroverthevalveandlower,toengage the stem adaptor to the actuator’s bore. Con-tinue to lower until the actuator seats on the bracketmounting surface. In order to align the bolt holes, itmaybenecessarytoloosenthevalve-to-bracketboltingtoallowmoreplay inthebracket.Themountingboltsshouldeasilyfitintotheboltholeswithoutanybinding.Ifneeded,turnorstroketheactuatorafewdegreesand/oradjusttheactuatortravelstops.Bolttheactuatortothebracket.

2.4 Adjustthetravelstopboltsoftheactuatorfortheproperopenandclosedvalvepositions,pervalvemanufactur-er’srecommendations.Pneumaticallystroketheactua-

torseveraltimestoassureproperoperation.Thestemadaptorshouldnotbindduringoperation.Iftheactua-tor isequippedwithanUltraSwitchorotheraccesso-ries,adjustthematthistime.

2.5 Toprolongactuatorlifeuseonlyclean,dryplantair.Lu-bricatedairisnotrequired,howeveritisrecommendedparticularlyforhighcycleapplications.Donotuselubri-catedairwithpositioners.

CAUTION! Lifting bolts holes on the actuator are for lifting the actuator modules only with eye bolts, not a complete valve and actuator assembly.

3 Travel Stop Adjustments

Allactuatedvalvesrequireaccuratetravel-stopadjust-ments at both ends of the stroke to obtain optimumperformance and valve seat life. The accumulation oftolerancesintheadaptionofactuatorstovalvesissuchthattheremustbearangeofadjustmentsforbothendsofthestroketoachieveoptimumperformance.

TheRGactuatorshavetravelstopadjustmentsinboththe clockwise and counter-clockwise directions. The+/-3degreeadjustmentfeatureprovidesshaftrotationfrom84to96degrees.

4 Maintenance Instructions

4.1 Disassembly Instructions

4.1.1 Disconnectallairandelectricalsuppliesfromactuator.

4.1.2 Removeallaccessoriesfromactuatoranddismountac-tuatorfromvalve.

4.1.3 DrawingReferences:Drg#263188,Drg#263189

4.2 Spring Module (see Fig.: 1)

CAUTION! Personal Injury may result if Step 2 is at-tempted before Step I is completed.

Fig.: 1 Spring Module

4 2

4 2

CW

CWW

Actuator Configuration

Page 5: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

5

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

4.2.1 Applyairpressuretoport2onFCW(port4onFCCW)actuator, raising pressure slowly, enough to releasespringpressurefromtheStopBolt(17).BackofffullybothStopBoltsontheTorqueModuleandreleaseairpressure.Thiswillrelievethespringpreload.

4.2.2 TheSpringModule isweldedintoan integralcompo-nentandcannotbedisassembled.Toremovefromac-tuator,removeSpringModuleendcover(60)andus-inganextendedsocketspanner/tubespanner,unscrewanddisconnectthePullRod(54)fromtheTorqueMod-ule.

CAUTION! Take extra care not to drop the socket/small

tools inside the spring can. Small objects dropped in-side may fall through the spring guide and get stuck in the spring coils.

NOTE: A retainer ring on the threaded side of the Pull Rod stops it from being removed completely from the Spring Module.

4.2.3 SlingtheSpringModuleusingliftingboltsontheMod-uleandremovetheAdapterNuts(19)andLockwash-ers(20).SpringModulecannowberemovedfromtheTorqueModule.

4.2.4 BeforereassemblingSpringModuletobody,makesurestud threadsarecleanof anydirt, shavings,orotherdebris.Cleanthreadswithragandsolventifrequired,andlubricatethreadswithananti-seizecompound.

NOTE: Support the Spring Module during removal so as not to damage the Pull Rod and the studs’ threads.

4.3 Pressure Module

4.3.1 Pressurizerodendofcylinder,enoughtostroketoend.Ventouttheairfromthecylinder.

4.3.2 Remove end cover plate/plug from pressure moduleandunscrewthepistonrodwithasocket/tubespanner.

4.3.3 Slingthepressuremodulefromtheeyebolts,removetheAdaptorStudNuts(19)andLockwashers(20)andtakethePressuremoduleofftheTorquemodule.

4.3.4 RemovetheTieRodNuts(37),theEndPlate(33)andTieRods(36).

4.3.5 SlidetheCylinder(34)overandoffthePiston(38),be-ingcarefulnottoscratchordentthehonedandchromeplatedsurfaceofthecylinder.

4.3.6 Slide out the Piston- Piston Rod assembly off theAdapterPlate(32).

4.3.7 Remove theRetainerRing(40)and take theSplitCollar(39)offthePistonRod(35).PullthePistonRodoffthePiston.

4.4 Torque Module (Body Group)

NOTE: Spring Module and Pressure Module must be removed before disassembling the Torque Module

4.4.1 RemovetheIndicator(29),iffitted.

4.4.2 RemoveTopCoverBolts(65)andthecover,O-ringandtheNamurShaftAssembly(15).

4.4.3 RemoveBodyCoverBolts,LockWashers(26)andThreadPlugs(31).

4.4.4 UsingtheremovedBodyCoverBolts,jackopenthecoverby threading in thebolts in the two tappedholesuntilcoverisseparatedenoughtopryapart.Takecare to jack theboltsevenly,as thecover ispositioned by four dowel pins, and cross loadingmaycausebending/breakageofpinsonsmallac-tuatorsizes.

4.4.5 GentlytapwithPU/PlastichammerandpullofftheGuideBar(2)fromthebody.

4.4.6 LiftYokeSubAssemblyoutofbodybore.

4.4.7 RemoveDelrinPlate(7)retainingscrews.PullouttheYokePin(9),andSliderBlock(10).

4.4.8 SlideouttheGuideBlock(11)outoftheYokeandremovethebottomSliderBlock.

4.4.9 Remove Yoke Seals (5) and Yoke Bushing (4) ifwornout/damaged.

4.5 Reassembly Instructions

4.5.1 Inspect all parts for wear and replace any wornparts as needed. Normally, all O-rings and sealsshouldbereplacedwhenreassemblinganactuator.Useseallubricant,DowCorning55foralllubrica-tioninthepressuregroup.

Ensure the replacement seals are suitable for theservicetemperature.

4.5.2 TheMetalbackedbronze-ptfebearingsmaybein-spectedandassessedforreplacement,referringtoguide(seeFig.:2)ontheusefulresiduallife

Toreplacethebearings,theunitorthesubassembly

Page 6: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

6

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

needstobebroughtintoworkshop,withsuitablefacilities to carefully remove the bearing withoutdamaging the housing and to press new bearingwithproperpressing toolspermanufacturer’s in-structionsandapress.

Donotattempttopryoutanyofthebearingsintheactuatorwithsharptools,orhammerinareplace-mentbearing.

4.5.3 Clean thoroughly and grease all Torque Modulecomponents with NLGI grade 2 multi-purposegrease.UseShellAlvaniaEP2forStandardActua-tors.Forlowtemperatureunits,useDow55greaseorequivalent.

4.5.4 Reverse thedisassemblyprocedures to reassem-ble.Applyrecommendedtorque,refertorquechart,ontheTieRodLocknuts,theMountingFlangeNuts,theBodyCover&TopPlatebolts,thePistonRod/PullRod(seetablesonpafe7.

The Tie Rod and Mounting Flange Stud threadsshouldbelubricatedwithLocktiteAntiseize,77164orequivalent.

ThePull/PistonRodthreadsandcoverboltstobetightenedwiththreadlockcompound,Loctite243orequivalent.

4.5.5 Refer to parts and materials drawings for all re-quiredspareparts(seepages9+10).

Test the actuator for smooth operation and airleakageatservicepressurebeforereinstallingintoservice.

5 Field Conversion from Fail CW to Fail CCW (ForSpringReturnActuators)

TheRGspringreturnactuatorcanbeconvertedfromfailCWtofailCCWeasily,withouthavingtoremovetheTorque Module, mounting bracket, stem adaptor andthe shaft driven accessories, mounted on the centrebody.SimplyswitchthepositionsofthePressureandSpringModules.

ActuatorDesignationneedstobesuitablychangedonthenameplate.

Followstepsbelow,ifoperatingthevalveispermitted:

5.1 Apply enough air pressure to the actuator to relievespringloadonthestopperbolt.

5.2 BackoffboththestopperboltsontheTorqueModuleanddepressurizetheactuator.

5.3 Remove Spring Module end cover, unscrew and dis-connecttheSpringPullRod.

5.4 Pressurize rod end of Pressure Module, to end ofstroke. Depressurize and remove the end cover/plugon the Pressure Module. Use a tube/socket spanner,loosenpistonrodbyoneturn,fitbackendcover/plugandpressurizecapend,enoughtostroketoend.De-pressurize, removeendcover/plug and fullyunscrewanddisconnectthepistonrodfromtheTorqueModule.

5.5 RemovethePressureandSpringModulesofftheTorqueModulebyremovingthemountingflangestudnuts.

Fig.: 2 Residual Life Guide

Page 7: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

7

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

5.6 Switchthepositionsofthetwomodules,connectthePressureModulefirstandensuretheportsareonthestopperboltssideofactuator.Threadinandtorquethepiston rod to recommendedvalue, fitbackendcoverplate/plug.Pressurizecapendtostroketheactuatortoend.

5.7 ReinstallSpringModule,torquethepullrodtorecom-mendedvalue,fitendcoverback.Pressurizerodendofcylinderandadjustthestopperbolts.

5.8 Checkactuatorforproperoperation,attheratedwork-ingpressure.

NOTE: If operation of valve is not permitted, during changing of the Fail Safe direction, then the actuator needs to be taken off the valve and reconfigured, as explained above.

Fastner Model RG1 RG2 RG3 RG4 RG5 RG6 RG7 RG8

Mounting Flange Nut

ThreadSize M8 M10 M12 M12 M16 M16

Tightningtorque

ftLb 10-12 18-22 30-35 30-35 80-90 80-90 140-160 280-320

kgm 1.4-1.7 2.5-3.0 4.2-4.8 4.2-4.8 11.0-12.5 11.0-12.5 19-22 38-44

Body Cover Bolts

ThreadSize M6 M6 M8 M8 M10 M10

Tightningtorque

ftLb 3-5 3-5 10-14 10-14 18-22 18-22 26-30 26-30

kgm 0.5-0.7 0.5-0.7 1.4-2.0 1.4-2.0 2.5-3.0 2.5-3.0 3.5-4.0 3.5-4.0

Top Plate Bolts

ThreadSize M6 M6 M8 M8 M10 M10

Tightningtorque

ftLb 3-5 3-5 10-14 10-14 18-22 18-22 22-26 22-26

kgm 0.5-0.7 0.5-0.7 1.4-2.0 1.4-2.0 2.5-3.0 2.5-3.0 3.0-3.5 3.0-3.5

Stopper Bolt Locknuts

ThreadSize M16 M20 M20 M30 M36 M48 M56 M64

Tightningtorque

ftLb 75-85 90-100 90-100 100-110 120-130 140-150 175-200 200-240

kgm 10-12 12-14 12-14 14-15 16-18 19-21 25-28 28-33

Piston Rod/Pull Rod

HexSize,A/F 18 18 24 30 36 46 65 85

Tightningtorque

ftLb 30-35 35-45 50-60 60-75 75-85 100-140 175-200 200-240

kgm 4-5 4-5 7-8 8-10 10-12 13-19 24-28 28-33

Bolt Torques

Cylinder Size (in.) 5 6 7 8 9 10 12 14 16 18 20 22 24 28 32 32T 36 36T 40

Tie Rod Nut Size M10 M10 M10 M10 M12 M12 M16 M16 M20 M20 M24 M24 M30 M30 M30 M36 M30 M36 M30

Tightening Torque (ft Lb)

8 11 14 19 28 34 64 88 143 181 268 325 485 330 431 1028 564 876 673

Tie Rod Nut Torque

Page 8: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

8

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

How to Order

SeriesBody Size

Cylinder Size ActionSpring Module

Torque Pattern (Yoke)

Sealing/Temp Manual Override Material/ Coatings Options

RG

1 05 06 07 08 09 10 12 DA- DoubleActing SingleCylinder 0 S- Symmetrical N- Nitrile,-20˚Fto180˚F

0- None GE- GreyEpoxy(std) 00- None

2 08 09 10 12 14 16 DD- DoubleActing DualCylinder 1 C- Canted G- SandwichDeclutchGbox PO- PrimerOnly TC- Ext.Stopper-CW

3 10 12 14 16 18 20 2 H- HighTemp(Viton),0˚Fto300˚F

J- Jackscrew WE- WhiteEpoxy TO- Ext.Stopper-CCW

4 14 16 18 20 22 24 3 D- BevelGearJackscrew SP- Specials TB- Ext.Stopper-BothDir

5 16 18 20 22 24 28 4 L- LowTemp,(material)-55˚Fto180˚F

H- Hydraulic S xxx- Specialscode

6 18 20 22 24 28 32 36 SR- SpringReturn FailCW 5

7 24 28 32 36 40 SO- SpringReturn FailCCW 6

8 28 32 36 40 7

8

Model Code Example:

RG 5 22 SR 6 C N D GE TC

Actuator Designation

Module Weights (approx.)Module Weights, Lbs (kgs)

ModelTorque Module

Pressure Module Spring Module5 6 7 8 9 10 12 14 16 18 20 22 24 28 32 36 40 1 2 3 4 5 6 7 8

RG1 68(31)

31(14)

35(16)

47(22)

53(24)

66(30)

94(43)

139(63) – – – – – – – – – – 88

(40)97

(44)101(46)

103(47)

106(48)

114(52)

119(54)

119(54)

RG2 99(45) – – – 56

(25)69

(32)99

(45)143(65)

209(95)

320(145) – – – – – – – – 128

(58)145(66)

154(70)

158(72)

158(72)

172(78)

180(82)

186(85)

RG3 143(65) – – – – – 100

(45)142(64)

200(91)

318(145)

406(185)

561(255) – – – – – – 226

(103)260

(118)267

(121)269

(122)276

(125)330

(150)321

(146) –

RG4 295(134) – – – – – – – 217

(99)339

(154)427

(194)586

(266)741

(337)942

(428) – – – – 402(183)

442(201)

462(210)

477(217)

510(232)

545(248)

565(257)

581(254)

RG5 510(231) – – – – – – – – 356

(162)455

(207)610

(277)853

(388)994

(452)1634(743) – – – 639

(290)737

(335)770

(350)783

(356)901

(410)955

(434) – –

RG6 933(423) – – – – – – – – – 493

(224)616

(280)861

(391)1051(478)

1732(787)

2321(1055)

3044(1384) – 1283

(583)1738(790)

1671(760)

1730(787)

2061(937)

1995(907) – –

RG7 1881(853) – – – – – – – – – – – – – 1824

(829)2411

(1096)3156

(1435)3913

(1779)2283

(1038)2946

(1339)3043

(1383)3177

(1444)3630

(1650)3709

(1686) – –

RG8 3718(1686) – – – – – – – – – – – – – 2165

(984)2819

(1282)3372

(1533)4159(1891

4627(2103)

5800(2637)

6113(2779)

6227(2830)

7111(3232)

7423(3374) – –

Body SizeMax. Cylinder Size

DA DD SR/SO

1 9 8 12

2 12 10 16

3 16 14 20

4 20 16 24

5 22 20 28

6 28 24 36

7 36 32 40

8 40 40 40

Page 9: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

9

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

Drawing # 263188

C

G G

16 17

181920

3233

3436

37

3844

4346 48 62 26 65

5051

52

53

5758

59 6061

23

3165

64

8

49

54

DET

AIL

A

42

45

DET

AIL

B

56 63

68

67 19

DET

AIL

C

353940

47

SEC

TION

G-G

12

3

45 6

7 65

12 13

1415 21 30 222426 66 28 29

41

91011

27

REVI

SIO

NS

ECO

NO

REV

ZON

ELT

R

DES

CRI

PTIO

ND

ATE

CHK

1PU

LL R

OD

UPD

ATE

D11

/24/

09SP

ITEM

N

O.

DES

CRI

PTIO

NM

ATE

RIA

LQ

TY.

1C

ENTE

R BO

DY

AST

M A

-536

Gr 6

0-40

-18

12

GUI

DE

ROD

STEE

L A

ISI 4

340

13

CO

VER

AST

M A

-536

Gr 6

0-40

-18

14

BUSH

PTFE

BRO

NZE

25

O-R

ING

BUN

A -

N2

6YO

KEA

STM

A-5

36 G

r 60-

40-1

81

7 R

ETA

INER

DEL

RIN

28

SCRE

WST

EEL

Gr 8

.812

9PI

NST

EEL

AIS

I 434

01

10 S

LID

ER B

LOC

KB-

150-

C62

400

211

GUI

DE

BLO

CK

STEE

L A

-148

Gr.

90-6

01

12BU

SHPT

FE B

RON

ZE2

13BU

SHPT

FE B

RON

ZE2

14PL

ATE

UNS

S316

001

15SH

AFT

UNS

S316

001

16N

UTST

EEL

Gr 8

217

STO

P BO

LTST

EEL

Gr 8

.82

ITEM

N

O.

DES

CRI

PTIO

NM

ATE

RIA

LQ

TY.

18ST

UDST

EEL

Gr 8

.812

19N

UTST

EEL

Gr 8

1220

WA

SHER

STEE

L12

21O

-RIN

GBU

NA

- N

122

O R

ING

BUN

A -

N1

23O

-RIN

GBU

NA

- N

224

BUSH

PTFE

BRO

NZE

125

PIN

SA-1

93-B

74

26 W

ASH

ERST

EEL

1827

CO

VER

STE

EL A

-36

128

SCRE

WST

EEL

Gr 8

.81

29 IN

DIC

ATO

RPL

AST

IC1

30O

-RIN

GBU

NA

- N

131

SCRE

WST

EEL

Gr 8

.82

32A

DA

PTO

RA

STM

A-5

36 G

r 60-

40-1

81

33EN

D C

AP

AST

M A

-536

Gr 6

0-40

-18

134

CYL

IND

ERSA

-106

-B1

ITEM

N

O.

DES

CRI

PTIO

NM

ATE

RIA

LQ

TY.

35 P

ISTO

N R

OD

STEE

L A

ISI 4

340

136

TIE R

OD

SA-1

93-B

74

37LO

CKN

UTST

EEL

Gr 8

438

PIST

ON

AST

M A

-536

Gr 6

0-40

-18

139

SPLI

T C

OLL

AR

SAE-

4140

440

RET

RIN

GUN

S S3

1600

141

EYE

BO

LTST

EEL

242

BUSH

PTFE

BRO

NZE

143

QUA

D S

EAL

RUBB

ER1

44W

EAR

RIN

GC

ARB

ON

FIL

LED

PTF

E2

45Q

UAD

SEA

LRU

BBER

146

O-R

ING

BUN

A -

N2

47O

-RIN

GBU

NA

- N

148

CO

VER

PLA

TE S

TEEL

A-3

61

49O

-RIN

GBU

NA

- N

150

AD

APT

OR

SA -2

16-W

CB

151

PIPE

STEE

L SA

-53-

B1

ITEM

N

O.

DES

CRI

PTIO

NM

ATE

RIA

LQ

TY.

52EN

D C

AP

SA

-216

-WC

B1

53SP

RIN

G G

UID

ESA

-216

-WC

B1

54PU

LL R

OD

STEE

L A

ISI 4

340

155

EYE

BO

LTST

EEL

256

BUSH

PTFE

BRO

NZE

157

SPRI

NG

AST

M A

689

516

OH

158

SPRI

NG

AST

M A

689

516

OH

159

BOLT

M16

STEE

L G

r 8.8

460

CO

VER

STE

EL A

-36

161

WA

SHER

STEE

L4

62O

-RIN

GBU

NA

- N

163

O-R

ING

BUN

A -

N1

64BU

TTO

NUH

MW

PE6

65BO

LTST

EEL

Gr 8

.824

66 P

INC

ARB

ON

STE

EL1

67O

-RIN

GBU

NA

- N

268

RET

RIN

GUN

S S3

1600

1

87

65

43

21

ABCD

12

34

56

78

D C B ATM

HD A

CTU

ATO

R, R

G S

ERIE

S

KNS

UNLE

SS O

THER

WIS

E SP

ECIF

IED

DIM

ENSI

ON

S A

RE IN

MILL

IMET

ERS

AN

D A

RE A

FTER

PLA

TING

.

X. .X .XX

1 .75

.25

THIR

D A

NG

LE P

ROJE

CTIO

N

CO

PYRI

GHT

- FL

OW

SERV

E C

ORP

ORA

TION

ALL

RIG

HTS

RESE

RVED

INFO

RMA

TION

IN T

HIS

DO

CUM

ENT

IS C

ON

FID

ENTIA

L A

ND

IS T

HEEX

CLU

SIV

E PR

OPE

RTY

OF

FLO

WSE

RVE

CO

RPO

RATIO

N, D

ELIV

ERY

OF

THIS

DO

CUM

ENT

OR

AN

Y C

OPY

THE

REO

F O

R D

ISC

LOSU

RE O

FSU

CH

INFO

RMA

TION

TO

UN

AUT

HORI

ZED

PER

SON

S IS

FO

RBID

DEN

.

DIM

ENSI

ON

S W

ITH

TO

LERA

NC

ESA

RE ID

EAL

DES

IGN

DIM

ENSI

ON

S.A

LL D

IMEN

SIO

NS

AN

D T

OLE

RAN

CES

PER

AN

SI Y

14.5

M -

1982

DO

NO

T SC

ALE

AN

GLE

S 1

/2

DRA

WIN

G N

O.

ENG

BY

CHK

BY

DRW

BY

SP

NEX

T A

SSY

REF

LAYO

UT

R UN

SPEC

RA

DII

DES

IGN

FILE

MA

CHI

NE

FIN

ISH

Ra

MA

TERI

AL

SIZE

6/10

/09

6/10

/09

D1RE

V

SCA

LESH

EET

1:10

1 O

F 1

Flow

Con

trol D

ivisi

onBG

LSI

TE

2631

88

3D12

Q1S

\SKA

LAN

IDHI

(11/

24/2

009

7:02

:06

PM)

Page 10: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

10

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

Drawing # 263189

46

44*

3930

36

40#

2

336

1

48

54#

61*

57

58

50

6251

49

16 17

5*

14

24

15

26

25

28*

42*

31

35

32

12#

13#

64

23

27

34

67

59

60*

7

11

3

53

65

20*

29

19*

5321

*

53

65

47*

38

8

4#

5*

1824

67

41*

45*

9

4#

39

43*

37

37

37

10

1062

61

63*

63*

52

68

NO

TE:

SEA

L KI

TS C

ON

TAIN

* M

ARK

ED P

ART

S1.

SERV

ICE

KITS

CO

NTA

INS #

MA

RKED

PA

RTS

2.

REVI

SIO

NS

ECO

NO

REV

ZON

ELT

R

DES

CRI

PTIO

ND

ATE

CHK

12

DPU

LL R

OD

UPD

ATE

D11

/24/

09SP

ITEM

N

O.

SHO

RTD

ESC

MA

TERI

AL

QTY

.1

CEN

TER

BOD

YD

UCTIL

E IR

ON

12

GUI

DE

ROD

ALL

OY

STEE

L1

3C

OV

ERD

UCTIL

E IR

ON

14#

BUSH

PTFE

BRO

NZE

25*

O-R

ING

BUN

A -

N2

6YO

KED

UCTIL

E IR

ON

17

RETA

INER

PLA

STIC

28

SCRE

W S

TEEL

129

PIN

ALL

OY

STEE

L1

10SL

IDER

BLK

AL

BRO

NZE

211

GUI

DE

BLO

CK

DUC

TILE

IRO

N1

12#

BUSH

PTFE

BRO

NZE

213

#BU

SHPT

FE B

RON

ZE2

14PL

ATE

STA

INLE

SS S

TEEL

115

SHA

FTST

AIN

LESS

STE

EL1

16N

UTST

EEL

217

STO

P BO

LT S

TEEL

2

ITEM

N

O.

SHO

RTD

ESC

MA

TERI

AL

QTY

.18

STUD

STE

EL12

19*

O-R

ING

BUN

A -

N1

20*

O R

ING

BUN

A -

N1

21*

O-R

ING

BUN

A -

N2

22#

BUSH

PTFE

BRO

NZE

123

PIN

ALL

OY

STEE

L4

24W

ASH

ER S

TEEL

1225

CO

VER

CA

RBO

N S

TEEL

126

SCRE

WPL

ATE

D S

TEEL

127

WO

RCES

TER

PLA

STIC

128

*O

-RIN

GBU

NA

- N

129

SCRE

WA

LLO

Y ST

EEL

230

AD

APT

OR

DUC

TILE

IRO

N1

31C

YLIN

DER

CA

RBO

N S

TEEL

132

END

CA

PD

UCTIL

E IR

ON

133

PIS

TON

RO

DA

LLO

Y ST

EEL

134

TIE R

OD

ALL

OY

STEE

L4

ITEM

N

O.

SHO

RTD

ESC

MA

TERI

AL

QTY

.35

LOC

KNUT

PLA

TED

STE

EL4

36PI

STO

ND

UCTIL

E IR

ON

137

SPLI

T C

OLL

AR

STE

EL4

38RE

T RI

NG

STE

EL1

39BO

LT S

TEEL

240

#BU

SHPT

FE B

RON

ZE1

41*

QUA

DSE

AL

RUBB

ER1

42*

WEA

R RI

NG

C F

ILLE

D P

TFE

243

*Q

UAD

SEA

LRU

BBER

144

*O

-RIN

GBU

NA

- N

245

*O

-RIN

GBU

NA

- N

146

CO

VER

PLA

TEC

ARB

ON

STE

EL1

47*

O-R

ING

BUN

A -

N1

48A

DA

PTO

RC

ARB

ON

STE

EL1

49PI

PEC

ARB

ON

STE

EL1

50EN

D C

AP

CA

RBO

N S

TEEL

151

SPRI

NG

GUI

DE

DUC

TILE

IRO

N1

ITEM

N

O.

SHO

RTD

ESC

MA

TERI

AL

QTY

.52

PULL

RO

DA

LLO

Y ST

EEL

153

BOLT

2454

#BU

SHPT

FE B

RON

ZE1

55SP

RIN

GA

LLO

Y ST

EEL

156

SPRI

NG

ALL

OY

STEE

L1

57BO

LT S

TEEL

458

CO

VER

CA

RBO

N S

TEEL

159

WA

SHER

STE

EL4

60*

O-R

ING

BUN

A -

N1

61*

O-R

ING

BUN

A -

N1

62BU

TTO

NPL

AST

IC6

63*

O-R

ING

BUN

A -

N2

64N

UT S

TEEL

1265

WA

SHER

STEE

L18

66RE

T RI

NG

STA

INLE

SS S

TEEL

167

BOLT

STE

EL2

68 P

INST

EEL

1

87

65

43

21

ABCD

12

34

56

78

D C B ATM

UNLE

SS O

THER

WIS

E SP

ECIF

IED

DIM

ENSI

ON

S A

RE IN

MILL

IMET

ERS

AN

D A

RE A

FTER

PLA

TING

.

X. .X .XX

1 .75

.25

THIR

D A

NG

LE P

ROJE

CTIO

N

CO

PYRI

GHT

- FL

OW

SERV

E C

ORP

ORA

TION

ALL

RIG

HTS

RESE

RVED

INFO

RMA

TION

IN T

HIS

DO

CUM

ENT

IS C

ON

FID

ENTIA

L A

ND

IS T

HEEX

CLU

SIV

E PR

OPE

RTY

OF

FLO

WSE

RVE

CO

RPO

RATIO

N, D

ELIV

ERY

OF

THIS

DO

CUM

ENT

OR

AN

Y C

OPY

THE

REO

F O

R D

ISC

LOSU

RE O

FSU

CH

INFO

RMA

TION

TO

UN

AUT

HORI

ZED

PER

SON

S IS

FO

RBID

DEN

.

DIM

ENSI

ON

S W

ITH

TO

LERA

NC

ESA

RE ID

EAL

DES

IGN

DIM

ENSI

ON

S.A

LL D

IMEN

SIO

NS

AN

D T

OLE

RAN

CES

PER

AN

SI Y

14.5

M -

1982

DO

NO

T SC

ALE

AN

GLE

S 1

/2

DRA

WIN

G N

O.

ENG

BY

CHK

BY

DRW

BY

NEX

T A

SSY

REF

LAYO

UT

R UN

SPEC

RA

DII

DES

IGN

FILE

MA

CHI

NE

FIN

ISH

Ra

MA

TERI

AL

SIZE

03/3

0/09

03/3

0/09

D1RE

V

SCA

LESH

EET

1:20

1 O

F 1

Flow

Con

trol D

ivisi

onBG

LSI

TE

EXPL

OD

ED V

IEW

, HD

AC

TUA

TOR,

RG

SER

IES

KNS

SP

2631

89

Page 11: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

11

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

7 Long Term Storage

Itisrecommendedtotakeprecautionsandcertainmeasureswhenstoringtheactuatorsforextendedperiodsoftime,morethan4monthstotwoyears.

Potentialproblemsandrecommendedprotectionsareasbelow:

6 Torque Shaft

Theoutputshaftisrecommendedtohavetwokeyen-gagements.Shaftmaterialshallbealloysteelwithmini-mum yield strength of 85,000psi. The recommendedhardnessofkeysis25-28HRc.

Recommendedengagementlengthofthekeysisasbe-low(seeFig.:3).

Model Lk (mm) Lo (mm)

RG1 165 180

RG2 195 210

RG3 200 215

RG4 255 270

RG5 300 315

RG6 350 375

RG7 500 515

RG8 585 610

Potential Problem Protection

Waterentryintopneumaticcylinder,degradesthecylinder,par-ticularlyinsalineorcorrosiveenvironment.Temperatureswingscausecondensationinsidecylinders

• Storeactuatorinclean,dryandprotectedwarehouse,orun-derventilateddustcover.

• Plugallportsafterpurgingwithdryinstrumentairornitro-gen.

• Storevertical,toavoidsealset.

Sealcompressionset Cycleactuator5-6timeswithcleandryinstrumentairornitro-gen,every3months.

Degradationofseals inexcessivelycorrosiveorhotenviron-ments

• Do not store in locations subjecting the actuator to tem-peraturesinexcessofsealrating.StdsealsareNitrile,maxtemp180degF.

• Donotstoreinenvironmentsharmfultoresilientseals.

Physicaldamagetoactuatororaccessories. Storeactuatorassemblyonskid,offthefloor,outofpathways.

Inspecttheprotectionsevery3monthsandrecordinspectionresults.

Fig.: 3 Key Length

Lk

Lo

Page 12: User Instructions RG Series Standard Actuator - … · 3 1 User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09 1.7 Service / repair To avoid possible injury to personnel

12

®

User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09

Alldatasubjecttochangewithoutnotice©©12.2009FlowserveCorporation.FlowserveandKämmeraretrademarksofFlowserveCorporation

Contact:

FlowserveCorporationhasestablishedindustryleadershipinthedesignandmanufactureofitsproducts.WhenproperlyselectedthisFlowserveproductisdesignedtoperformitsintendedfunctionsafelyduringitsusefullife.However,thepurchaseroruserofFlowserveproductsshouldbeawarethatFlowserveproductsmightbeusedinnumerousapplicationsunderawidevarietyofindustrialserviceconditions.AlthoughFlowservecan(andoftendoes)providegeneralguidelines,itcannotprovidespecificdataandwarningsforallpossibleapplications.Thepurchaser/usermustthereforeassumetheultimateresponsibilityforthepropersizingandselection,installation,operation,andmaintenanceofFlowserveproducts.Thepurchaser/usershouldreadandunderstandtheInstallationOperationMaintenance(IOM)instructionsincludedwiththeproduct,andtrainitsemployeesandcontractorsinthesafeuseofFlowserveproductsinconnectionwiththespecificapplication.

Whiletheinformationandspecificationscontainedinthisliteraturearebelievedtobeaccuratetheyaresuppliedforinformativepurposesonlyandshouldnotbeconsideredcertifiedorasaguaranteeofsatisfactoryresultsbyreliancethereon.Nothingcontainedhereinistobeconstruedasawarrantyorguarantee,expressedorimplied,regardinganymatterwithrespecttothisproduct.BecauseFlowserveiscontinuallyimprovingandupgradingitsproductdesign,thespecifications,dimensionsandinformationcontainedhereinaresubjecttochangewithoutnotice.Shouldanyquestionariseconcerningtheseprovisions,thepurchaser/usershouldcontactFlowserveCorporationatanyoneofitsworldwideoperationsoroffices.

Flowserve CorporationFlow Control Division1978ForemanDriveCookeville,Tennessee38501USAPhone:+9314324021Fax:+9314325518www.flowserve.com

Flowserve CorporationFlow Control Division1350NorthMountainSpringsParkwaySpringville,Utah84663-0913USAPhone:+8013733028Fax:+8014892228

Flowserve Pte LtdNo.12TuasAvenue20Singapore638824Phone:+6568798900Fax:+6568624940

Flowserve Flow Control (UK) Ltd.BurrellRoadHaywardsHeathWestSussexUnitedKingdomRH161TLPhone:+441444314400Fax:+441444314401

AutomaxImgroßRohr2Limburg,Hessen65549GermanyPhone:+49(0)643196610Fax:+49(0)6431966130

Flowserve Ahaus GmbHvon-Braun-Str.19a48683AhausPhone:+492561686-119Fax:+492561686-109

Flowserve Flow Control GmbHActuators and Automation CenterGermanyRudolfPlankStr.2D-76275EttlingenGermanyPhone+49(0)72431030Fax+49(0)7243103222

Flowserve Flow Control Benelux BVRechtzaad174703RCRoosendaalNBNetherlandsPhone:+31165598800Fax:+31165555670

Flowserve Australia Pty LtdFlowControlDivision14DalmoreDriveScoresby,Victoria3179AustrialiaPhone:+61397593300Fax:+61397593301

Flowserve S.R.LViaPrealpi30CormanoMIItalyI-20032Phone:+3902663251Fax:+39026151863

Flowserve do Brasil LtdaRuaTocantins,128-BairroNovaGertiSãoCaetanodoSul,SãoPaulo09580-130BrazilPhone:+551142316300Fax:+551142316329-423

Unit 01\02\06\07 9FChinaFortuneTowerNo.1568,CenturyAvenue,PudongShanghaiChina200122Phone:+862138654800Fax:+862150811781

Flowserve CorporationNo.35,BaiyuRoadSuzhouIndustrialParkSuzhou 215021, Jiangsu Province,PRCPhone:+86-512-6288-1688Fax:+86-512-6288-8737