Critical Load Protection from a Brand Name You Recognize
Advanced Features (Standard on all G8000 UPS Systems) 0.98 Input Power Factor
Low Input Current THD
Generator Friendly
Space Saving Footprint
Front Access Design
Isolated Redundant Systems 7x24 Monitoring and Service
SNMP/HTTP Remote Monitoring
User Friendly, SimpleOperator Interface
Redundant Inputs
IGBT Technology
Global UPS
Toshiba Quality and Reliability
When considering a UPS System numerous features and benets of eachsystem must be evaluated. Surges, sags, brownout and blackouts areserious concerns facing a computer or telecommunications center. Suchpower quality issues are a leading cause of equipment failure. The G8000 isan industrial UPS designed to meet all critical application needs.
G8000 Series UPSwww.tic.toshiba.com
G8000 Series UPS 150, 225, 300kV
-
8/6/2019 UPS225-Toshiba G8000
2/4
Critical Load Protection from
The G8000 Power Module concept by Toshiba reduces reected input
current harmonics, increases Power Factor (pf) to greater than 0.98. Input
pf correction enables the current THD to be less than 3%. As a result of
lowering the input THD and increasing the input pf, generator sizing can
be reduced to a ratio of 1:1. This signicantly lowers installation and
project costs.
Current harmonics reected back to the utility are load dependent with
many UPS vendors. The lower the load the higher the total harmonics
distortion (THD). 100% Load is not typical. 50-75% Load is more normal on installed systems. 6 Pulse rectier with inpu
lters will have an Input THD approximately 18-25%, and 12 Pulse rectier with input lters will have 10-15%. Toshibas
G8000 has a maximum of 6% input current THD.
The user friendly, secure operator interface offers a graphical LCD, LED mimic display and
keypad for navigation. This versatile display allows the user to have TOTAL ACCESS of
all the operating information on the UPS. Other functions include: time stamp event log,
battery condition, self diagnosis and current UPS status.The user can also monitor: UPS
performance, Mode of Operation, Output Voltage and Fault Status. The graphics panel
illustrates the basic operation of the UPS system. This feature enables the user immediate
status of the UPS.
Graphics panel enabling immediate status and operation
Easily scanned guidance display
Easy-to-read digital metering display
Event Display
Key Lock for Operations
Secure Operation Interface
Input Power Factor (0.98), Low Input Current THD, GeneratorFriendly
G8000 Mimic Display
SNMP/HTTPThe optional RemotEyeII features a HTTP (Web-based) interface for TOSHIBA UPS. This
allows easy access to the TOSHIBA UPS information from any PC/Network with a web
browser. At any time, a network workstation or server can open a RemotEyeII website and
monitor its operation and status. RemotEyeII provides access to 3 Java applets for monitor
ing, event logging, and trend analysis. In addition, RemotEyeII can integrate the UPS into an SNMP management system
and the ability to perform multiple server shutdowns. Through both techniques, UPS system Information can be congured
remotely. Remote contacts are also available to give the user multiple paths for monitoring the G8000.
Toshiba UPS system protects against power outages in such elds as nance related online systems, communications sys-
tems and plant control equipment that must operate 24 hours a day, 365 days a year. Electrical noise and distorted voltage
waveforms may cause less than optimal computer performance. The Toshiba UPS utilizes IGBT technology at 16 to 25 kHz
to produce the cleanest sinewave output. A clean sinewave is a good measure of the quality and reliability of the UPS.
-
8/6/2019 UPS225-Toshiba G8000
3/4
and Name You Recognize
www.tic.toshiba.com
The memory card stores various digital and analog system data.
The data stored in the memory card consists of: analog data with
27 variables, digital data with 19 variables and event history of 10
events (recording time of each event is 500ms). Waveform data
stored on the memory card can be regenerated and analyzed by a
personal computer. This approach can facilitate diagnosis of faults
and reduce down time.
Toshiba provides the industry with the highest quality UPS product in the world. We backup our statement with our 3 year
warranty*. Through rigorous testing and careful quality control, Toshiba has set a new standard in reliability and perfor-
mance. Toshiba is the only manufacture in the world to offer a standard three year warranty on 150 kVA and above UPS sys-
tems. The batteries, if provided by Toshiba, also carry a 2 year full and remaining years prorated warranty. Onsite service
is within 4 hours subject to location and country of purchase. See Toshiba warranty terms and conditions for details.
3 Year Warranty!!
Isolated RedundantThe TOSHIBA G8000 Series is congurable in Isolated Redun-
dant Congurations for extremely critical applications, service-
ability and High 9s availability.
InvertersThree individualmodules for 100%
unbalanced load andto reduce service time
Contactors:Input, Output, Bypassdisconnecting devices
Terminals:3 phase 3 wireinput, 3 phase 4 wirebypass, 3 phase4 wire output, 2 poleDC and Ground.
Redundant Fans:Easy access forservice on the redun-
dant exhaust fans.
DC Inductors:DC Filtering forreduced ripple tobattery system.
Output IsolationTransformer:Provides additionalisolation protection tothe load.
Memory Card
G8000 Series UPS System Layout
Customer Alarm Contacts StandardRemoteye II OptionSmart Card Option
* The Toshiba G8000 UPS 3 year warranty does require a preventative maintenance visit in years 2 and 3 to validate this warranty.
-
8/6/2019 UPS225-Toshiba G8000
4/4
G8000 Series UPS 150, 225, 300 kVA
INTERNATIONAL CORPORATION
INDUSTRIAL DIVISION13131 West Little York Rd.Houston, Texas 77041713/466-0277 Fax 713/466-8773US 800/231-1412
www.tic.toshiba.com Copyright 1-2003 Toshiba International Corporation Email: [email protected]
G8000System Features
0.98 Input Power Factor
Low Input Current THD
Generator Friendly
Space Saving Footprint
Front Access Design
Isolated Redundant Systems
7x24 Monitoring and Service
SNMP/HTTP Remote Monitoring
User Friendly, Simple Operator Interface
Redundant Inputs
IGBT Technology
Global UPS
Toshiba Quality and Reliability
Options & Miscellaneous Equipment
SNMP/HTTP Network Adapter
Smart Memory Card
Input/Output Transformers of All Voltage
Congurations
Maintenance Bypass Panels
Battery Cabinets
Battery Racks
Battery Disconnects
PDUs
Battery Monitor Systems
Technical SpecifcationsSystem Rated kVA (kw) Capacity 150kVA 225kVA 300kVA
(120kw) (180kw) (240kw)
Input 3-Ph/3-W Maximum AC Input Current 180A 271A 361A
3-Ph/3-W Nominal AC Input Current 165A 248A 330A
3-Ph/4-W Bypass AC Input Current 180A 271A 361A
Rated Input Voltage 480V, 3 Phase/ 3 Wire
Rated Input Frequency 50/60Hz
Input Power Factor >0.98
Input Current THD 0.98 PF)
Alternate Input480Y/277V,
3Ph/4W,
50/60 Hz
150kVA
Output XFMR
THY. SW.
D Y
* Some derating required at 50Hz