UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID...

77
2014 PRODUCT CATALOGUE UPSAC INVERTERHYBRID INVERTERSOLAR CHARGER CONTROLLERAVR

Transcript of UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID...

Page 1: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

2014 PRODUCT CATALOGUE

UPS.AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER.AVR

Page 2: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

WHY CENTRAION?

Centralion Industrial Inc. (“Centralion”)

was founded in 1979 and has become a

leading developer of power quality

solutions since 1989. With more than 30

years of experiences in the industry,

Centralion’s power products have served all

over the world as key components in

power systems which required UPS,

Inverter or AVR, and Centralion has won its

reputation as a trustful and reliable partner

for its customers.

Page 3: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

INDEX

Product series marked with “Z” are designed for 100-120V system. Product specification and outlook are subject to change without prior notice.

Online UPS INNOVA ONL - 01

INNOVA+ ONL - 05

INNOVA+ Z ONL - 07

INNOVA COMBO ONL- 09

INNOVA RT ONL - 11

INNOVA HD ONL - 15

JAGA ONL - 17

Line-interactive UPS SPRING MT LIN - 01

SPRING MTZ LIN - 03

SPRING RT LIN - 05

AURORA LIN - 09

AURORA VISTA LIN - 11

UNI LIN - 13

UNI Z LIN - 15

BLAZER VISTA LIN - 17

Modular UPS GRIPOWER PRO MDL - 01

3-Phase UPS APUS 3PH - 01

APUS Z 3PH - 03

AC Inverter HYBRID ACI - 01

INVEREX ACI - 03

INVEREX S ACI - 05

INVEREX Z ACI - 07

INVEREX HD ACI - 09

Solar Charger Controller

SOLAR MATE SCC - 01

AVR HOSTA AVR - 01

VANDA AVR - 03

IBERIS AVR - 05

Accessory NMC CARD ACC - 01

AS400 CARD ACC - 01

CMC CARD ACC - 01

MINI NMC CARD ACC - 02

MINI AS400 CARD ACC - 02

MINI CMC CARD ACC - 02

RELAY CARD ACC - 03

USB/RS232CARD ACC - 03

Environmental Monitoring

Probe (EMP) ACC - 03

EXTERNAL CHARGER ACC - 04

Automatic Transfer Switch

(ATS) ACC - 04

COMPATIBILITY MATRIX ACC - 05

Standby UPS APFC OFFICE STB - 01

MAXOFFICE Z STB - 03

MAXPOWER STB - 05

DC UPS STB - 07

Page 4: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

INNOVA series • True double-conversion design with high adaptability to harsh mains

conditions

• DSP design enables precise and reliable control

• High efficiency results in energy saving

• Automatic boost/buck voltage regulation (± 2%)

• Supports energy-saving ECO mode

• Intelligent communication slot enables remote monitoring

• LCD display shows easy-to-understand operational status

1K

2

K / 3

K

ONL - 01

Page 5: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL INNOVA 1K INNOVA 1KS INNOVA 2K INNOVA 2KS INNOVA 3K INNOVA 3KS

CAPACITY 1000VA/800W 2000VA/1600W 3000VA/2400W

INPUT

Input Voltage Range 110 ~ 300 VAC Frequency Range 45 Hz– 55 Hz/54 Hz – 66 Hz Input Wiring Single phase with ground

Current Distortion (THDi) <5% @ full load

OUTPUT

Output Power Factor 0.8 Nominal Output Voltage 2001/2082/220/230/240VAC Voltage Regulation ±2 % Frequency Range ( Battery Mode ) 50 / 60 ± 0.2Hz Current Crest Ratio 3:1 Voltage Distortion (THDv) < 3% @ linear load, < 5%@ non-linear load Output Waveform Pure sine wave

Parallel Operation N/A

EFFICIENCY Inverter Mode 88% Battery Mode 85% ECO Mode 93% 94%

BATTERY

Battery Type 12V / 7Ah N/A 12V / 7Ah N/A 12V / 7Ah N/A Number of Internal Battery 3 N/A 8 N/A 8 N/A Rated Battery Voltage 36V 96V 96V Backup Time (@ Full Load) > 5min N/A > 9min N/A > 5min N/A Recharge Time (to 90%) 5 hour N/A 5 hour N/A 5 hour N/A Charging Current 1A 8A 1A 8A or 12A (optional) 1A 8A or 12A (optional)

TRANSFER TIME Battery Mode ↔ Inverter Mode 0ms Inverter Mode ↔ Bypass Mode 4ms ECO Mode ↔ Battery Mode <10ms

DISPLAY LCD AUDIBLE ALARM Yes DIMENSION WxHxD 145 X 220 X 400 mm 192 X 347 X 460 mm NET WEIGHT 13 kg 7 kg 31 kg 13 kg 31 kg 13 kg

ENVIRONMENT Operating Temperature 0~45 °C Noise Level 50dB @1 meter

INTERFACE RS232/USB Yes External Slot Yes Emergency Power Off Yes

Note: 1. 200VAC will be subject to 80% output derating 2. 208VAC will be subject to 90% output derating

ONL - 02

Page 6: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

INNOVA series • True double-conversion design with high adaptability to harsh mains

conditions

• DSP design enables precise and reliable control

• High output power factor (0.9)

• High efficiency results in energy saving

• Automatic boost/buck voltage regulation (±1%)

• Supports energy-saving ECO mode

• Intelligent communication slot enables remote monitoring

• LCD display shows easy-to-understand operational status

• Supports up to 4-unit parallel operation

6K

/ 10

K

ONL - 03

Page 7: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL INNOVA 6K INNOVA 6KS INNOVA 10K INNOVA 10KS CAPACITY 6000VA/5400W 10000VA/9000W

INPUT

Input Voltage Range 110~276VAC

Frequency Range 45-55Hz / 54-66Hz Input Wiring Single phase with ground

Current Distortion (THDi) <5% @ full R load

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 2081/220/230/240VAC

Voltage Regulation ± 1 % Frequency Range ( Battery Mode ) 50/60 ± 0.05 Hz Current Crest Ratio 3:1 Voltage Distortion (THDv) <2% @ Linear Load, <5% @ Non-Linear Load Output Waveform Pure Sine Wave

Parallel Operation Up to 4 units

EFFICIENCY Inverter Mode >92% Battery Mode >92% ECO Mode >96%

BATTERY

Battery Type 12V/7Ah N/A 12V/9Ah N/A Number of Internal Battery 20 N/A 20 N/A Rated Battery Voltage 240VDC

Backup Time (@ full load) > 5min N/A > 4 min N/A Recharge Time (to 90%) 5 hour N/A 5 hour N/A Charging Current 1.4A 4A 1.4A 4A

TRANSFER TIME Battery Mode ↔ Inverter Mode 0ms Inverter Mode ↔ Bypass Mode 0ms ECO Mode ↔ Battery Mode 10ms

DISPLAY LCD AUDIBLE ALARM Yes DIMENSION WxHxD 260 x 708 x 550 mm NET WEIGHT 88 kg 25.5 kg 84 kg 29.5 kg

ENVIRONMENT Operating Temperature 0-45° C Noise Level ≤50dB @ 1 Meter

INTERFACE RS232/USB RS23: optional, USB: standard External Slot Yes Emergency Power Off Yes

Note: 1. 208VAC will be subject to 90% output derating

ONL - 04

Page 8: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

INNOVA+ series • True double-conversion design with high adaptability to harsh mains

conditions

• DSP design enables precise and reliable control

• High efficiency results in energy saving

• Output power factor (0.9)

• Automatic boost/buck voltage regulation (± 2%)

• Supports energy-saving ECO mode

• Intelligent communication slot enables remote monitoring

1K

2

K / 3

K

ONL - 05

Page 9: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL INNOVA+ 1K INNOVA+ 1KS INNOVA+ 2K INNOVA+ 2KS INNOVA+ 3K INNOVA+ 3KS CAPACITY 1000VA/900W 2000VA/1800W 3000VA/2700W

INPUT

Input Voltage Range 110 ~ 300 VAC Frequency Range 45~55 Hz/54~66 Hz Input Wiring Single Phase with Ground Current Distortion (THDi) <5% with full load

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 2001/2082/220/230/240VAC Voltage Regulation ±2 % Frequency Range ( Battery Mode ) 50/60Hz ±0.2 Hz Current Crest Ratio 3:1 Voltage Distortion (THDv) <3% @ linear load, <5% @non-linear load Output Waveform Pure Sine Wave Parallel Operation N/A

EFFICIENCY Inverter Mode 87% 88% Battery Mode 85% ECO Mode 93% 94%

BATTERY

Battery Type 12V / 7Ah N/A 12V / 7Ah N/A 12V / 7Ah N/A Number of Internal Battery 3 N/A 8 N/A 8 N/A Rated Battery Voltage 36V 36V 96V 96V 96V 96V Backup Time (PF0.8 , full load) 5 min N/A 9 min N/A 5 min N/A Recharge Time (to 90%) 5 hours N/A 5 hours N/A 5 hours N/A

Charging Current 1A 8A 1A 8A or 12A(optional) 1A 8A or 12A(optional)

TRANSFER TIME

Battery Mode ↔ Inverter Mode 0ms Inverter Mode ↔ Bypass Mode <4ms

ECO Mode ↔ Battery Mode <10ms

DISPLAY LCD AUDIBLE ALARM Yes DIMENSION WxHxD 145 X 220 X 400 mm 192 X 347 X 460 mm NET WEIGHT 13 kg 7 kg 31 kg 13 kg 31 kg 13 kg

ENVIRONMENT Operating Temperature 0~45 °C

Noise Level <50dB @1 meter

INTERFACE USB Yes External Slot Yes

Emergency Power Off Yes Note: 1. 200VAC will be subject to 80% output derating 2. 208VAC will be subject to 90% output derating

LIN - 06

Page 10: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

INNOVA+ Z series • High-frequency design and full-digital DSP control provide optimal

performance

• High output power factor (0.9)

• Wide input voltage range (55~150VAC)

• Precise output voltage regulation ( 2%)

• Graphic LCD display

• Intelligent communication slot enables remote monitoring

• Supports ECO mode and power segments

• cTÜ Vus certified

1K

2

K / 3

K

ONL - 07

4.5

Page 11: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL INNOVA+ Z 1K INNOVA+ Z 2K INNOVA+ Z 3K CAPACITY 1000VA/900W 2000VA/1800W 3000VA/2700W

INPUT

Input Voltage Range 55~150VAC

Frequency Range 46-54Hz / 56-64Hz Input Wiring Single phase with ground Current Distortion (THDi) <19% with full R load <17% with full R load <18% with full R load

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 1001/1102/115/120VAC/127VAC

Voltage Regulation ≤2 % Frequency Range ( Battery Mode ) 50/60Hz ±0.5 Hz Current Crest Ratio 3:1 Voltage Distortion (THDv) <5% @ linear load ; <8% @ non-linear load Output Waveform Pure sine wave Parallel Operation N/A

EFFICIENCY Inverter Mode 88.0% Battery Mode 83.0% ECO Mode 96.0%

BATTERY

Battery Type 12V/7Ah 12V/7Ah 12V/9Ah Number of Internal Battery 3 6 6 Rated Battery Voltage 36V 72V 72V Backup Time (@ Full Load) >4.5 min >4.5 min >3 min Recharge Time (to 90%) 5 hours

Charging Current 1A 0.7A

TRANSFER TIME Battery Mode ↔ Inverter Mode 0ms Inverter Mode ↔ Bypass Mode <4ms ECO Mode ↔ Battery Mode <10ms

DISPLAY LCD AUDIBLE ALARM Yes

DIMENSION WxHxD 145 X 220 X 345 mm 190 X 318 X 369 mm NET WEIGHT 12.5 kg 25 kg 27.1 kg

ENVIRONMENT Operating Temperature 0~40 °C Noise Level <45dB

INTERFACE RS232/USB Yes External Slot Yes Emergency Power Off Yes

Note: 1. 100VAC will be subject to 90% output derating for 1K and 3K models, and 80% output derating for 2K model 2. 110VAC will be subject to 90% output derating for 2K model

ONL - 08

Page 12: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

INNOVA COMBO series • True double-conversion design to deal with harsh mains conditions

• High output power factor (0.9)

• Precise output voltage regulation ( 1%)

• Wide AC input voltage range (110-276VAC)

• LCD display shows easy-to-understand operational status

• Supports energy-saving ECO mode

• Two Intelligent communication slots and one RS232 port enable up to 3

channels remote monitoring

• Supports parallel connection for up to 4 units

10

K / 2

0K

ONL - 09

Page 13: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL INNOVA COMBO 10K INNOVA COMBO 20K CAPACITY 10000 VA/ 9000W 20000VA/18000W

INPUT

Input Voltage Range 110VAC-276VAC (Single Phase Input) 190VAC-478VAC (Three Phase Input)

Frequency Range 45Hz ~ 55Hz / 54Hz ~ 66Hz Input Wiring Single Phase with Ground (L-N-G) /Three Phase with Ground (R-S-T-N-G) Current Distortion (THDi) < 5% @ full R load

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 2001/208/220/230/240VAC Voltage Regulation ± 1 % Frequency Range ( Battery Mode ) 50/60 ± 0.05 Hz Current Crest Ratio 3:1

Voltage Distortion (THDv) <2% @ Linear Load, <5% @ Non-Linear Load

Output Waveform Pure Sine Wave Parallel Operation Up to 4 units

EFFICIENCY Inverter Mode >93% Battery Mode >93% ECO Mode >97%

BATTERY

Battery Type 12V/9Ah Number of Internal Battery 24x1 24x2 Rated Battery Voltage 288VDC 288 VDC

Backup Time (@ Full Load) >5 minutes Recharge Time (to 90%) 3 hours 5 hours Charging Current 2A 4A

TRANSFER TIME Battery Mode ↔ Inverter Mode 0ms

Inverter Mode ↔ Bypass Mode 0ms ECO Mode ↔ Battery Mode <10ms

DISPLAY LCD AUDIBLE ALARM Yes DIMENSION WxHxD 350 x 890 x 650 NET WEIGHT 115 kg 183 kg

ENVIRONMENT Operating Temperature 0-45° C Noise Level <55dB @ 1 Meter

INTERFACE RS232/USB Yes External Slot Yes Emergency Power Off Yes

Note: 1. 200VAC will be subject to 90% output derating

ONL - 10

Page 14: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

INNOVA RT series • True double-conversion design with high adaptability to harsh mains

conditions

• Ideal to for high-end equipment which are sensitive to power quality

• Supports energy-saving ECO mode

• Wide input range (120-176VAC)

• Intelligent communication slot enables remote monitoring

• Precise output voltage regulation (1%)

• Rack/tower dual set-up with rotatable LCD panel

1K

/ 1.5

K / 2

K / 3

K

ONL - 11

Page 15: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL INNOVA RT 1K INNOVA RT 1KS INNOVA RT 1.5K INNOVA RT 1.5KS INNOVA RT 2K INNOVA RT 2KS INNOVA RT 3K INNOVA RT 3KS

CAPACITY 1000VA/900W 1500VA/1350W 2000VA/1800W 3000VA/2700W

INPUT

Input Voltage Range 120~176VAC

Frequency Range 45~55Hz/54~66Hz Input Wiring Single Phase with ground Current Distortion (THDi) <5% @ full load

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 208/220/230/240VAC

Voltage Regulation ± 1% Frequency Range ( Battery Mode ) 50/60 ± 0.2 Hz Current Crest Ratio 3:1 Voltage Distortion (THDv) <2% @ Linear Load, <5% @ Non-Linear Load Output Waveform Pure Sine Wave

Parallel Operation N/A

EFFICIENCY Inverter Mode 88% 89% 92% Battery Mode 83% 84% 88% ECO Mode 95%

BATTERY

Battery Type 12V/7Ah N/A 12V/7Ah N/A 12V/9Ah N/A 12V/9Ah N/A Number of Internal Battery 3 N/A 4 N/A 4 N/A 6 N/A Rated Battery Voltage 36VDC 48VDC 48VDC 72VDC

Backup Time (@ Full Load) > 5min N/A > 5min N/A > 5min N/A > 5min N/A Recharge Time (to 90%) 3 hour N/A 3 hour N/A 3 hour N/A 3 hour N/A Charging Current (max) 1.5A 6A 1.5A 6A 1.5A 6A 1.5A 6A

TRANSFER TIME

Battery Mode ↔ Inverter Mode 0 ms Inverter Mode ↔ Bypass Mode 4 ms

ECO Mode ↔ Battery Mode <10 ms

DISPLAY LCD AUDIBLE ALARM Yes

DIMENSION WxHxD 438 x 86.5 x 435 mm 438 X 86.5X 604 mm

NET WEIGHT 16.2 kg 8.4 kg 19.7 kg 9.3 kg 19.7 kg 9.3kg 27.8 kg 13 kg

ENVIRONMENT Operating Temperature 0-40° C Noise Level <45dB @ 1 Meter <50dB @ 1 Meter

INTERFACE RS232/USB Yes External Slot Yes

Emergency Power Off Yes

ONL - 12

Page 16: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

INNOVA RT series • True double-conversion design with high adaptability to harsh mains

conditions

• Ideal to for high-end equipment which are sensitive to power quality

• Supports energy-saving ECO mode

• Wide input range (120-276VAC)

• Intelligent communication slot enables remote monitoring

• Precise output voltage regulation (1%)

• Independent input for bypass operation

6K

1

0K

ONL - 13

Page 17: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL INNOVA RT 6K INNOVA RT 6KS INNOVA RT 10K INNOVA RT 10KS CAPACITY 6000VA/5400W 10000VA/9000W

INPUT

Input Voltage Range 120~276VAC

Frequency Range 45-55Hz / 54-66Hz Input Wiring Single phase with ground Current Distortion (THDi) <5% @ full load

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 208/220/230/240VAC

Voltage Regulation ± 1% Frequency Range ( Battery Mode ) 50/60 ± 0.1 Hz Current Crest Ratio 3:1 Voltage Distortion (THDv) <2% @ Linear Load, <5% @Non-Linear Load Output Waveform Pure Sine Wave

Parallel Operation N/A

EFFICIENCY Inverter Mode 92% 93% Battery Mode 89% 90% ECO Mode 96% 97%

BATTERY

Battery Type 12V/5Ah N/A 12V/9Ah N/A Number of Internal Battery 15 N/A 20 N/A Rated Battery Voltage 180VDC 240VDC Backup Time (@ Full Load) >2.5mins N/A > 3.5mins N/A

Recharge Time (to 90%) 3 hours N/A 3 hours N/A Charging Current 1A 8A 1.7A 8A

TRANSFER TIME Battery Mode ↔ Inverter Mode 0 ms Inverter Mode ↔ Bypass Mode 0 ms ECO Mode ↔ Battery Mode <10 ms

DISPLAY LCD AUDIBLE ALARM Yes DIMENSION WxHxD 438 x 129x 698 mm 438 x 129x 640 mm 438 x 215.5x 704 mm 438 x 215.5x 640 mm

NET WEIGHT 46kg 19 kg 82.5kg 26kg

ENVIRONMENT Operating Temperature 0-40° C Noise Level <55dB @ 1 Meter

INTERFACE RS232/USB Yes External Slot Yes Emergency Power Off Yes

ONL - 14

Page 18: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

INNOVA HD series • True double-conversion design with high adaptability to harsh mains

conditions

• DSP design enables precise and reliable control

• High efficiency results in energy saving

• Output power factor 0.9

• Precise voltage regulation (± 2 %)

• Intelligent communication slot enables remote monitoring

• Standard rack design for installation in cabinet

1K

/ 2K

/ 3K

ONL - 15

Page 19: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL INNOVA HD 1K INNOVA HD 2K INNOVA HD 3K CAPACITY 1000VA/900W 2000VA/1600W 3000VA/2700W

INPUT

Input Voltage Range 80~144VAC 90~138VAC

Frequency Range 50/60Hz Input Wiring Single phase with ground Current Distortion (THDi) <8%

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 1001/1102/120/127VAC

Voltage Regulation 2% Frequency Range ( Battery Mode ) 50/60Hz 0.1 Hz Current Crest Ratio 3:1 Voltage Distortion (THDv) < 3 % @ linear load, < 5 % @ non-linear load Output Waveform Pure sine wave Parallel Operation N/A

EFFICIENCY Inverter Mode 87% 88% 90% Battery Mode 82% 84% ECO Mode 93%

BATTERY

Battery Type 12V/9Ah Number of Internal Battery 3 6 Rated Battery Voltage 36V 72V Backup Time (@ full load) 6 min 6 min 3 min Recharge Time (to 90%) 3 hours

TRANSFER TIME Battery Mode ↔ Inverter Mode 0 ms Inverter Mode ↔ Bypass Mode 4 ms ECO Mode ↔ Inverter Mode 10 ms

DISPLAY LCD AUDIBLE ALARM Yes DIMENSION WxHxD 438 x 86.5 x 445 mm 438 x 86.5 x 610 mm NET WEIGHT 16 kg 29 kg 29 kg

ENVIRONMENT Operating Temperature 0 ~ 40 °C

Noise Level <50 dBA

INTERFACE RS232/USB Yes External Slot Yes Emergency Power Off Yes

Note: 1. 100VAC will be subject to 80% output derating 2. 110VAC will be subject to 90% output derating

ONL - 16

Page 20: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Online UPS

TYPICAL APPLICATION

JAGA series • True double-conversion design with high adaptability to harsh mains

conditions

• DSP design enables precise and reliable control

• High efficiency results in energy saving

• Output power factor 0.8 (up to 0.9 under 30℃)

• Wide AC input range (110-300VAC)

• Automatic switching between 50/60Hz system

• Precise voltage regulation (± 1 %)

• Supports AC generator

• Supports DC start-up and auto restart

• Intelligent communication slot enables remote monitoring

1K

2

K / 3

K

ONL - 17

Page 21: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Online UPS

MODEL JAGA 1K JAGA 2K JAGA 3K CAPACITY 1000VA/800W 2000VA/1600W 3000VA/2400W

INPUT

Input Voltage Range 110~300VAC

Frequency Range 40-70Hz Input Wiring Single phase with ground Current Distortion (THDi) <10%

OUTPUT

Output Power Factor 0.8 Nominal Output Voltage 2001/2082/220/230/240VAC Voltage Regulation ± 2 % Frequency Range ( Battery Mode ) 50/60 ± 0.05 Hz Current Crest Ratio 2.95:1 Voltage Distortion (THDv) < 4% @ linear load, < 7% @ non-linear load Output Waveform Pure sine wave Parallel Operation N/A

EFFICIENCY Inverter Mode >89% >90% Battery Mode >83% >83% >83% ECO Mode N/A

BATTERY

Battery Type 12V/45W Number of Internal Battery 2 4 6 Rated Battery Voltage 24VDC 48VDC 72VDC

Backup Time (@ Full Load) 4.5 min 4.5 min 4.5 min Recharge Time (to 90%) 7 hours 7 hours 7 hours Charging Current (max) 1A 1A 1A

TRANSFER TIME Battery Mode ↔ Inverter Mode 0ms Inverter Mode ↔ Bypass Mode 4ms

DISPLAY LCD AUDIBLE ALARM Yes DIMENSION WxHxD 144 x 229 x 345 mm 190 x 328 x 393 mm NET WEIGHT 9.2 kg 17.2 kg 22.6 kg

ENVIRONMENT Operating Temperature 0 ~ 40 °C Noise Level <45dB <50dB

INTERFACE RS232 Yes External Slot Yes Emergency Power Off No

Note: 1. 200VAC will be subject to 80% output derating 2. 208VAC will be subject to 80% output derating

ONL - 18

Page 22: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

SPRING MT series • High performance supported by sinewave output and built-in voltage

regulator

• Compact foot print fits easily into small spaces such as kiosks, cash machines

and ticket machines

• HID Power Device-compliant USB interface enables integration with built-in

power management and auto shutdown features of Windows and Mac OS

and Linux

• High conversion efficiency (>95%) results in energy saving

• LCD graphic display gives comprehensive information at a glance

• Easy battery replacement

10

00

/ 15

00

5

00

/ 75

0

LIN - 01

Page 23: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL SPRING MT 500 SPRING MT 750 SPRING MT 1000 SPRING MT 1500 CAPACITY 500VA/350W 750VA/450W 1000VA/700W 1500VA/900W

INPUT Input Voltage Range 176-288VAC

Frequency Range 45-55 Hz / 55-65 Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.7 0.6 0.7 0.6 Nominal Output Voltage 220/230/240VAC

Voltage Regulation (Line Mode) -10% ~ +6% Voltage Regulation (Battery Mode) -10% ~ +6% Frequency Range ( Battery Mode ) 50/60 Hz ±0.1 Hz Output Waveform Pure sine wave Parallel Operation N/A

EFFICIENCY Line Mode > 94% AVR Mode > 90% Battery Mode > 70%

BATTERY

Battery Type 12V/7Ah 12V/9Ah 12V/7Ah 12V/9Ah Number of Internal Battery 1 1 2 2 Rated Battery Voltage 12VDC 24VDC

Backup Time (@ Typical PC load) 17 min 20 min 35 min 40 min

Recharge Time (to 90%) 3 hours

TRANSFER TIME Battery Mode ↔ Line Mode <10ms DISPLAY LCD

AUDIBLE ALARM Yes

DIMENSION WxHxD 150x209X240 mm 150x209x340 mm NET WEIGHT 6.4 kg 6.8 kg 10.8 kg 11.5 kg

ENVIRONMENT Operating Temperature 0~40° C Noise Level <40dBA @ 1 meter <45 dBA@1 meter

INTERFACE USB Yes

LIN - 02

Page 24: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

SPRING MTZ series • Designed for 110/120VAC AC grid system

• High performance supported by sinewave output and built-in voltage

regulator

• Compact foot print fits easily into small spaces such as kiosks, cash machines

and ticket machines

• HID Power Device-compliant USB interface enables integration with built-in

power management and auto shutdown features of Windows and Mac OS

and Linux

• High conversion efficiency (>95%) results in energy saving

• LCD graphic display gives comprehensive information at a glance

• Easy battery replacement

10

00

/ 15

00

5

00

/ 75

0

LIN - 03

Page 25: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL SPRING MTZ 500 SPRING MTZ 750 SPRING MTZ 1000 SPRING MTZ 1500 CAPACITY 500VA/350W 750VA/450W 1000VA/700W 1440VA/900W

INPUT Input Voltage Range 88-144VAC

Frequency Range 45-55 Hz / 55-65 Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.7 0.6 0.7 0.625 Nominal Output Voltage 100/110/120VAC

Voltage Regulation (Line Mode) -10% ~ +6% Voltage Regulation (Battery Mode) -10% ~ +6% Frequency Range ( Battery Mode ) 50/60 Hz ±0.1 Hz Output Waveform Pure sine wave Parallel Operation N/A

EFFICIENCY Line Mode > 94% AVR Mode > 90% Battery Mode > 70%

BATTERY

Battery Type 12V/7Ah 12V/9Ah 12V/7Ah 12V/9Ah Number of Internal Battery 1 1 2 2 Rated Battery Voltage 12VDC 24VDC

Backup Time (@ Typical PC load) 17 min 20 min 35 min 40 min

Recharge Time (to 90%) 3 hours

TRANSFER TIME Battery Mode ↔ Line Mode <10ms DISPLAY LCD

AUDIBLE ALARM Yes

DIMENSION WxHxD 150x209X240 mm 150x209x340 mm NET WEIGHT 6.4 kg 6.8 kg 10.8 kg 11.5 kg

ENVIRONMENT Operating Temperature 0~40° C Noise Level <40dBA @ 1 meter <45 dBA@1 meter

INTERFACE USB Yes

LIN - 04

Page 26: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

SPRING RT series • High output power factor (0.9)

• Built-in voltage regulator stables unstable AC input power

• Intelligent communication slot enables remote monitoring

• HID Power Device-compliant USB interface enables integration with built-

in power management and auto shutdown features of Windows and Mac

OS and Linux

• Rack/tower dual set-up with rotatable LCD panel

• Optional EBM (Extended Battery Module) available for battery expansion

1K

/ 1.5

K

LIN - 05

Page 27: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL SPRING RT 1K SPRING RT 1KS SPRING RT 1KE SPRING RT 1.5K SPRING RT 1.5KS

CAPACITY 1000VA/900W 1500VA/1350W

INPUT

Input Voltage Range 154~288VAC

Frequency Range 45-55Hz / 55-65 Hz

Input Wiring Single phase with ground

Current Distortion (THDi) 10%

OUTPUT

Output Power Factor 0.9

Nominal Output Voltage 220/230/240VAC

Voltage Regulation (Line Mode) -10% ~ +6%

Voltage Regulation (Battery Mode) ± 5 %

Frequency Range ( Battery Mode ) 50/60 Hz ± 0.1 Hz

Voltage Distortion (THDv) < 3% @ linear load, < 6% @ non-linear load < 10% @ linear load < 3% @ linear load, < 6% @ non-linear load

Output Waveform Pure sine wave

Parallel Operation N/A

EFFICIENCY

Line Mode 97%

AVR Mode Boost mode: 92%, Buck mode: 95%

Battery Mode >82% >80% >82%

BATTERY

Battery Type 12V/7Ah N/A 12V/9Ah 12V/9Ah N/A

Number of Internal Battery 3 N/A 2 3 N/A

Rated Battery Voltage 36VDC 24VDC 36VDC

Backup Time (@ full load) 4.5 min N/A 3min 3 min N/A

Recharge Time (to 90%) 3 hours N/A 8 hours 4 hours N/A

Charging Current 1.5A 7A 1.1A 1.5A 7A

TRANSFER TIME Battery Mode ↔ Line Mode 2-6 ms

DISPLAY LCD

AUDIBLE ALARM Yes

DIMENSION WxHxD 438 X 86.5 x 435 mm

NET WEIGHT 16kg 10kg 13kg 17.9kg 10kg

ENVIRONMENT Operating Temperature 0~40°C

Noise Level <45dB

INTERFACE

RS232/USB Yes

External Slot Yes N/A Yes

Dry Contact Yes N/A Yes

LIN - 06

Page 28: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

SPRING RT series

2K

/ 3K

• High output power factor (0.9)

• Built-in voltage regulator stables unstable AC input power

• Intelligent communication slot enables remote monitoring

• HID Power Device-compliant USB interface enables integration with built-

in power management and auto shutdown features of Windows and Mac

OS and Linux

• Rack/tower dual set-up with rotatable LCD panel

• Optional EBM (Extended Battery Module) available for battery expansion

LIN - 07

Page 29: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL SPRING RT 2K SPRING RT 2KS SPRING RT 2KE SPRING RT 3K SPRING RT 3KS CAPACITY 2000VA/1800W 3000VA/2700W

INPUT

Input Voltage Range 154~288 VAC

Frequency Range 45-55Hz / 55-65 Hz Input Wiring Single phase with ground Current Distortion (THDi) 10%

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 220/230/240VAC

Voltage Regulation (Line Mode) -10% ~ +6% Voltage Regulation (Battery Mode) ± 5 % Frequency Range ( Battery Mode ) 50/60 Hz ± 0.1 Hz Voltage Distortion (THDv) < 3% @ linear load, < 6% @ non-linear load Output Waveform Pure sine wave Parallel Operation N/A

EFFICIENCY

Line Mode 97%

AVR Mode Boost mode: 92%, Buck mode: 95% Battery Mode 80%

BATTERY

Battery Type 12V/7Ah N/A 12V/9Ah 12V/9Ah N/A Number of Internal Battery 6 N/A 4 6 N/A Rated Battery Voltage 72VDC 48VDC 72VDC

Backup Time (@ full load) 4.5 min N/A 3 min 3 min N/A Recharge Time (to 90%) 3 hours N/A 4 hours 4 hours N/A

Charging Current 1.5A 7A 1.5A 1.5A 7A TRANSFER TIME Battery Mode ↔ Line Mode 2-6 ms DISPLAY LCD

AUDIBLE ALARM Yes

DIMENSION WxHxD 438 X 86.5 x 604 mm 438 X 86.5 x 436 mm 438 X 86.5 x 604 mm NET WEIGHT 28kg 16kg 21kg 31kg 16kg

ENVIRONMENT Operating Temperature 0~40°C Noise Level <45dB

INTERFACE RS232/USB Yes External Slot Yes Dry Contact Yes

LIN - 08

Page 30: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

AURORA series • Entry-level backup solution with excellent performance

• Build-in voltage regulator for reliable power quality

• DC start function enables UPS to be started up without AC power

• Green Power Function for energy saving

• Auto restart while AC recovery

• AC Overloading protection

• Surge protection for phone / modem line

• CE compliant

45

0 / 6

50

/ 85

0

12

00

/ 22

00

LIN - 09

Page 31: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL ARURORA 450 AURORA 650 AURORA 850 AURORA 1200 AURORA 2200

CAPACITY 450VA/240W 650VA/360W 850VA/480W 1200VA/600W 2200VA/1100W

INPUT Input Voltage Range 162-290 VAC

Frequency Range 45~55Hz/55~65Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.55 0.5 Nominal Output Voltage 110/120/220/230/240 VAC Voltage Regulation (Line Mode) ±15% Voltage Regulation (Battery Mode) ±10%

Frequency Range ( Battery Mode ) 50/60Hz 1Hz Output Waveform Modified sine wave Parallel Operation N/A

EFFICIENCY Line Mode 95% AVR Mode 88% Battery Mode 60%

BATTERY

Battery Type 12V/4.5Ah 12V/7Ah 12V/9Ah 12V/7Ah 12V/9Ah Number of Internal Battery 1 1 1 2 2

Rated Battery Voltage 12VDC 12VDC 12VDC 24VDC 24VDC

Backup Time (@ Typical PC load) 8 min 16 min 20 min 40 min 50 min Recharge Time (to 90%) 6 hours Charging Current 1A

TRANSFER TIME Battery Mode ↔ Line Mode 2-6 ms 4-8 ms DISPLAY LED AUDIBLE ALARM YES DIMENSION WxHxD 100 x 143 x 300 139 X 195 x 364

NET WEIGHT 3.5kg 4.5kg 5.0kg 8.8kg 10.3kg

ENVIRONMENT Operating Temperature 0~40°C Noise Level <40dB <45dB

LIN - 10

Page 32: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

AURORA VISTA series • Entry-level backup solution with excellent performance

• Build-in voltage regulator for reliable power quality

• DC cold start function

• Auto restart while AC recovery

• Front panel USB interface for easy installation(650/850)

• Easy-to-understand graphic LCD display

• AC Overloading protection

• Surge protection for phone / modem line

• CE compliant

65

0 / 8

50

1

20

0 / 2

20

0

LIN - 11

Page 33: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL AURORA VISTA 650 AURORA VISTA 850 AURORA VISTA 1200 AURORA VISTA 2200 CAPACITY 650VA/360W 850VA/480W 1200VA/600W 2200VA/1200W

INPUT Input Voltage Range 162~290VAC

Frequency Range 45~55/55~65 Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.55 0.56 0.5 0.55 Nominal Output Voltage 220/230/240 VAC

Voltage Regulation (Line Mode) ±15%

Voltage Regulation (Battery Mode) ±10%

Frequency Range ( Battery Mode ) 50/60Hz 1 Hz Output Waveform Modified sine wave Parallel Operation N/A

EFFICIENCY Line Mode 95% AVR Mode 88% Battery Mode 60%

BATTERY

Battery Type 12V/7Ah 12V/9Ah 12V/ 7Ah 12V/9Ah Number of Internal Battery 1 1 2 2 Rated Battery Voltage 12VDC 12VDC 24VDC 24VDC

Backup Time (@ Typical PC load) 16 min 20 min 30 min 50 min

Recharge Time (to 90%) 6 hours Charging Current 1A

TRANSFER TIME Battery Mode ↔ Line Mode 2-6 ms 4-8 ms DISPLAY LCD

AUDIBLE ALARM Yes DIMENSION WxHxD 100 x 143x 290 139 x 195 x 364 NET WEIGHT 2.36 kg 2.7 kg 5.3 kg 5.93 kg

ENVIRONMENT Operating Temperature 0~40°C Noise Level <40dB <45dB

INTERFACE USB Yes External Slot No TVSS protection RJ11 Jack RJ45 Jack

LIN - 12

Page 34: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

UNI series • Ideal backup power solution for home and office

• Optimized design leads to cost-saving and space-saving

• Built-in AVR with boost and buck circuit to deal with challenging

power conditions

• Compact size which can be easily fit with PC-related equipment

• Top access of outlet makes power core connection easier

60

0

LIN - 13

TOP VIEW

Page 35: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL UNI 600

CAPACITY 600VA/360W

INPUT Input Voltage Range 150~290VAC

Frequency Range 47~53/57~63 Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.6 Nominal Output Voltage 230VAC

Voltage Regulation (Line Mode) N/A Voltage Regulation (Battery Mode) ±10% Frequency Range ( Battery Mode ) 50 1 Hz Output Waveform Modified sine wave Parallel Operation N/A

EFFICIENCY Line Mode >95% AVR Mode N/A

Battery Mode >60%

BATTERY

Battery Type 12V/4.5Ah Number of Internal Battery 1 Rated Battery Voltage 12VDC

Backup Time (@ 120W load) 7.9 min

Recharge Time (to 90%) 6 hours Charging Current N/A

TRANSFER TIME Battery Mode ↔ Line Mode 4-6 ms DISPLAY LED AUDIBLE ALARM Yes DIMENSION WxHxD 100 x 143x 200 NET WEIGHT 3.8kg

ENVIRONMENT Operating Temperature 0~40°C Noise Level <40dB

INTERFACE USB No External Slot No TVSS protection No

LIN - 14

Page 36: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

UNI Z series

• Ideal backup power solution for home and office

• Optimized design leads to cost-saving and space-saving

• Built-in AVR with boost and buck circuit to deal with challenging

power conditions

• Compact size which can be easily fit with PC-related equipment

• Top access of outlet makes power core connection easier

50

0

LIN - 15

Page 37: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL UNI Z 500

CAPACITY 500VA/300W

INPUT Input Voltage Range 92~142VAC

Frequency Range 42~70 Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.6 Nominal Output Voltage 120VAC

Voltage Regulation (Line Mode) N/A Voltage Regulation (Battery Mode) ±10%

Frequency Range ( Battery Mode ) 50±1Hz / 60±1Hz

Output Waveform Modified sine wave Parallel Operation N/A

EFFICIENCY Line Mode >95% AVR Mode N/A Battery Mode >60%

BATTERY

Battery Type 12V/4.5Ah Number of Internal Battery 1 Rated Battery Voltage 12VDC

Backup Time (@ 120W load) 7.9 min

Recharge Time (to 90%) 6 hours Charging Current N/A

TRANSFER TIME Battery Mode ↔ Line Mode 4-6 ms DISPLAY LED AUDIBLE ALARM Yes DIMENSION WxHxD 100 x 143x 200 NET WEIGHT 3.8kg

ENVIRONMENT Operating Temperature 0~40°C

Noise Level <40dB

INTERFACE USB No External Slot No TVSS protection No

LIN - 16

Page 38: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Line-interactive UPS

TYPICAL APPLICATION

BLAZER VISTA series • Equipped with boost and buck AVR to stabilize output voltage

• Built-in DC start function Easy-to-understand graphic LCD display

• Smart RS232 port for remote monitoring

• Easy battery replacement design

• Auto self-charge under off status

• Auto self-restart upon AC recovery

• Surge protection for modem or phone lines

• Protection against over-charge, over-discharge, over-loading

40

0 / 6

00

/ 80

0

10

00

/ 14

00

/ 20

00

LIN - 17

Page 39: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Line-interactive UPS

MODEL BLAZER VISTA 400 BLAZER VISTA 600 BLAZER VISTA 800 BLAZER VISTA 1000 BLAZER VISTA 1400 BLAZER VISTA 2000 CAPACITY 400VA/240W 600VA/360W 800VA/480W 1000VA/600W 1400VA/840W 2000VA/1200W

INPUT Input Voltage Range 162-290VAC 166~290VAC

Frequency Range 45~55/55~65 Hz 45~55/55~65 Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.6 Nominal Output Voltage 220/230/240VAC

Voltage Regulation (Line Mode) ±15% Voltage Regulation (Battery Mode) ±10% ±5% Frequency Range ( Battery Mode ) 50/60Hz±1Hz Output Waveform Modified sine wave Parallel Operation No

EFFICIENCY Line Mode >95% AVR Mode >88% Battery Mode >60%

BATTERY

Battery Type 12V/4.5Ah 12V/7Ah 12V/9Ah 12V/7Ah 12V/9Ah Number of Internal Battery 1 1 1 2 2 Rated Battery Voltage 12VDC 24VDC

Backup Time (@ typical PC load) 10 min 18 min 22 min 40 min 45 min Recharge Time (to 90%) 8 hours 10 hours 6 hours

Charging Current 1 A 0.7A TRANSFER TIME Battery Mode ↔ Line Mode 2-6 ms 4-6 ms 4-8 ms DISPLAY LCD AUDIBLE ALARM YES DIMENSION WxHxD 100X140X330 205X145X405 NET WEIGHT 4.3 kg 4.97 kg 6.15 kg 9.6 kg 9.7 kg 9.8 kg

ENVIRONMENT Operating Temperature 0- 40°C Noise Level <40dBA <45dBA

INTERFACE RS232/USB Yes/Optional

TVSS protection Yes

LIN - 18

Page 40: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Standby UPS

TYPICAL APPLICATION

APFC OFFICE series • Supports loads with APFC (Active Power Factor Correction)

switch power supply with patented design

• Quick installation and easy to operate

• Easy battery replacement

• Surge protection for all receptacles

• Jack for phone/model lines with surge protection

• Easy-to-understand LED indicator

• Protection against faults and overloading

APFC loads

80

0

40

0 / 6

00

STB - 01

Page 41: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Standby UPS

MODEL APFC OFFICE 400 APFC OFFICE 600 APFC OFFICE 800 CAPACITY 400VA/200W 600VA/300W 800VA/420W

INPUT Input Voltage Range 170~270VAC

Frequency Range 45~55/55~65 Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.5 0.525

Nominal Output Voltage 230VAC

Voltage Regulation (Battery Mode) 10%

Frequency Range ( Battery Mode ) 50Hz/60Hz 1Hz Output Waveform Modified sine wave

EFFICIENCY Line Mode >95% Battery Mode >70%

BATTERY

Battery Type 12V/4.5Ah 12V/5Ah 12V/7Ah

Number of Internal Battery 1 Rated Battery Voltage 12V Backup Time (@ typical PC load) 9 min 17 min 20 min Recharge Time (to 90%) < 10 hours Charging Current 0.5A 1A

TRANSFER TIME Battery Mode ↔ Line Mode 2-8 ms DISPLAY LED AUDIBLE ALARM YES

DIMENSION WxHxD 320 x 125 x 86 mm 335 x 170 x 92.5 mm NET WEIGHT 3.7 kg 5 kg

ENVIRONMENT Operating Temperature 0- 40°C Noise Level <40dB

INTERFACE TVSS Protection Yes

STB - 02

Page 42: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Standby UPS

TYPICAL APPLICATION

MAXOFFICE Z series • UL and FCC Part 15 Class B compliant

• High-frequency design and full-digital control provide optimal

performance

• Provides professional protections against lightning, surge, spike,

brownout and blackout

• Battery-replaceable design enables easy maintenance

• Easy-to-understand LED indicators

• Pro-active audible alarms

• Quick installation and easy to operate

42

5 / 6

25

STB - 03

Page 43: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Standby UPS

MODEL MAXOFFICE Z 425 MAXOFFICE Z 625 CAPACITY 425VA/225W 625VA/315W

INPUT Input Voltage Range 120 VAC ± 15%

Nominal Frequency 50/60Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.529 0.5

Nominal Output Voltage 120VAC

Voltage Regulation (Battery Mode) ± 10%

Frequency Range ( Battery Mode ) 50/60 Hz ± 1Hz

Output Waveform Modified Sine Wave

BATTERY

Battery Type 12V/2.9Ah 12V/4.5Ah Number of Internal Battery 1 Rated Battery Voltage 12V

Backup Time (@ typical PC load) 5~7 min 7~12 min Recharge Time (to 90%) 10 hours

TRANSFER TIME Battery Mode ↔ Line Mode 2-6 ms DISPLAY LED AUDIBLE ALARM Yes DIMENSION WxHxD 125X85X300 mm

NET WEIGHT 2.8 kg 3.5 kg ENVIRONMENT Operating Temperature 0~40°C

INTERFACE TVSS Protection Yes

STB - 04

Page 44: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Standby UPS

TYPICAL APPLICATION

MAXPOWER series • Microprocessor control guarantees high reliability

• Built-in DC start function

• Simple installation and easy to operate

• Automatic detection of AC mains failure

• Auto restart while AC recovery

• Self diagnosis ensures longer battery life

• Provides discharge, over-charge, and overload protection

(MaxPower 1000 only)

10

00

4

00

/ 60

0

STB - 05

Page 45: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Standby UPS

MODEL MAXPOWER 400 MAXPOWER 600 MAXPOWER 1000 CAPACITY 400VA/200W 600VA/300W 1000VA/600W

INPUT Input Voltage Range 90-145VAC / 170-270VAC

Frequency Range 50Hz/60Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.5 0.6 Nominal Output Voltage 110/120VAC or 220/230/240VAC

Voltage Regulation (Battery Mode) 110/120VAC or 220/230/240VAC±10%

Frequency Range ( Battery Mode ) 50Hz/60Hz 1Hz Output Waveform Modified sine wave

EFFICIENCY Line Mode >95% Battery Mode >70%

BATTERY

Battery Type 12V/4.5Ah 12V/7Ah 12V/7.2Ah Number of Internal Battery 1 1 2

Rated Battery Voltage 12V Backup Time (@ typical PC load) 6~9 min 13~20 min 30 min Recharge Time (to 90%) 10 hours

TRANSFER TIME Battery Mode ↔ Line Mode 2~6 ms DISPLAY LED AUDIBLE ALARM Yes DIMENSION WxHxD 80 x 230 x 176.5 mm 90.6 x 237.7 x 280 mm NET WEIGHT 2.5 kg 3.1 kg 6.5 kg

ENVIRONMENT Operating Temperature 0- 40°C Noise Level <45dB

INTERFACE TVSS Protection Yes

STB - 06

Page 46: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Standby UPS

TYPICAL APPLICATION

DC UPS series • Ideal backup power solution for DC-powered equipment (e.g.

network and telecom)

• Integrated hot-swappable for battery replacement

• Universal input range (80~260VAC) for global application

• Microprocessor controlled for optimized performance and

reliability

• Supports cold-start function

• Easy-to-understand LED indicators

STB - 07

Page 47: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Standby UPS

MODEL DC UPS CAPACITY 30W

INPUT Input Voltage Range 80~260VAC

Frequency Range 45Hz~65Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 1 Nominal Output Voltage 12VDC

Output Voltage Range 10.5~13.8VDC

Output current 2.2A max EFFICIENCY Line Mode >80%

BATTERY

Battery Type 12V/7Ah Number of Internal Battery 1 Rated Battery Voltage 12VDC

Backup Time (@ 1A discharging) 340 min

Recharge Time (to 90%) 4 hours Charging Current 2.5A max

DISPLAY LED AUDIBLE ALARM Yes DIMENSION WxHxD 120x348x80 mm NET WEIGHT 4 kg ENVIRONMENT Operating Temperature 0 – 40 ℃ INTERFACE Output Terminal (7 pin) 2 pin for DC output, 5 pin for dry contact

STB - 08

Page 48: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Modular UPS

TYPICAL APPLICATION

GRIPOWER PRO series • Supports up to 10x15KVA UPS modules up to 150KVA output capacity

• Hot-swappable UPS module with wireless design

• N+X parallel redundant configuration which leaves no SPOF (Single Point of

Failure)

• 7” colorful touch-screen LCD

• Easy installation and load expansion resulted from modular design

• 3 multi-function intelligent ports

• Dynamic load-sharing design

• Optimized performance with >93% efficiency

• Supports AC generator as AC input

• Configurable battery quantity from 32 to 42 pieces per set

power module

MDL - 01

Page 49: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Modular UPS

MODEL Gripower Pro CAPACITY Each Module 15KVA/13.5kW

Max. Module in Parallel 10

INPUT

Input Voltage Range 304-520 VAC Frequency Range 40-70 Hz Input Wiring 3-phase/4-wire + PE Current Distortion (THDi) <5% @ 100% RCD load

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 353/380/400/415 VAC

Voltage Regulation ±1% Frequency Range ( Battery & Converter Mode )

50/60Hz ±0.05Hz

Current Crest Ratio 2.5:1 Voltage Distortion (THDv) <2% @ linear load, <4% @ non-linear load Output Waveform Pure sine wave

Cabinet Parallel Operation N/A

EFFICIENCY Inverter Mode 93% Battery Mode 93%

BATTERY

Battery Connection External Number of Battery 32~40 pcs Rated Battery Voltage ± Kx12 VDC (K = 16 to 20) Charging Current per Module 3.5A

TRANSFER TIME Battery Mode ↔ Inverter Mode 0 ms

Inverter Mode ↔ Bypass Mode 0 ms DISPLAY 7” touch panel LCD AUDIBLE ALARM Yes CABINET DIMENSION WxHxD 600x2030x1000 NET WEIGHT 90KVA: 230kg / 120KVA: 265kg / 150KVA: 275kg

ENVIRONMENT Operating Temperature 0 – 40 ℃ Noise Level <62dBA

INTERFACE RS232/USB Yes External Slot Supports SNMP/AS400/NMC/CMC card Emergency Power Off Yes

MDL - 02

Page 50: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

3-Phase UPS

TYPICAL APPLICATION

APUS series

• 3-Phase, double-conversion online UPS

• Up to 98% efficiency under High Efficiency mode results in significant

energy saving

• Intelligent management of battery charging prolongs battery lifetime

• Pre-wired for easy installation

• Up to 35% smaller than similar competitive solutions

• Allows dedication of more floor space to revenue producing equipment

50

K / 6

0K

/ 80

K

40

K

30

K

15

K / 2

0K

3PH - 01

Page 51: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

3-Phase UPS

MODEL APUS 15K APUS 20K APUS 30K APUS 40K APUS 50K APUS 60K APUS 80K CAPACITY 15KVA/13.5KW 20KVA/18KW 30KVA/27KW 40KVA/36KW 50KVA/45KW 60KVA/54KW 80KVA/72KW

INPUT

Input Voltage Range 190~478VAC

Frequency Range 42~70Hz Input Wiring 3 phases + Neutral + PE Current Distortion (THDi) <5%

OUTPUT

Output Power Factor 0.9 Nominal Output Voltage 380/400/415VAC

Voltage Regulation 1% Frequency Range ( Battery Mode )

50/60 Hz 0.005Hz

Current Crest Ratio 3:1 Voltage Distortion (THDv) 2% with linear load, <5% with non-linear load Output Waveform Pure sine wave Parallel Operation Yes

EFFICIENCY Inverter Mode 94% ECO Mode 98%

BATTERY

Battery Type N/A Number of Internal Battery N/A Rated Battery Voltage 384VDC / 408VDC / 432VDC Backup Time N/A

Recharge Time (to 90%) N/A

Charging Current 5.3A 8A 10.6A 16A 24A

TRANSFER TIME Battery Mode ↔ Inverter Mode 0ms Inverter Mode ↔ Bypass Mode 0ms ECO Mode ↔ Inverter Mode 4ms

DISPLAY Graphical LCD, 4x LEDs AUDIBLE ALARM Yes

DIMENSION WxHxD (mm) 500 x 960 x 710 500 x 1230 x 710 500 x 1500 x 710 600 x 1880 x 800

NET WEIGHT (without battery) TBD

ENVIRONMENT Operating Temperature 0-40C Noise Level ≤55dB @ 75% Load ≤62dB @ 75% Load ≤65dB @ 75% Load

INTERFACE RS232/USB Yes External Slot Yes Emergency Power Off Yes

3PH - 02

Page 52: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

3-Phase UPS

TYPICAL APPLICATION

APUS Z series • Double-conversion online UPS

• Up to 98% efficiency under High Efficiency mode results in significant

energy saving

• Intelligent management of battery charging prolongs battery lifetime

• Pre-wired for easy installation

• Up to 35% smaller than similar competitive solutions

• Delivers up to 21 minutes backup time

• Allows dedication of more floor space to revenue producing equipment

• UL compliant

20

K / 3

0K

4

0K

/ 60

K

3PH - 03

Page 53: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

3-Phase UPS

MODEL APUS Z 20K APUS Z 30K APUS Z 40K APUS Z 60K CAPACITY 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/48KW

INPUT

Nominal Input Voltage 208 / 220VAC

Input Voltage Range 176.8~250VAC

Frequency Range 40~72Hz

Input Wiring 3Ph+N+PE

Current Distortion (THDi) < 5%

OUTPUT

Output Power Factor 0.8 Nominal Output Voltage 208/220VAC (3-phase, 4-wire)

Voltage Regulation ±1%

Frequency Range ( Battery Mode ) 50Hz/60Hz

Output Waveform Pure sine wave Parallel Operation Up to 4 units

EFFICIENCY Inverter Mode 92% HE Mode 98%

BATTERY Battery Type 12V/9Ah

Backup Time (@ full load) 21 min 12 min 10 min 5 min

TRANSFER TIME Battery Mode ↔ Inverter Mode 0ms Inverter Mode ↔ Bypass Mode 0ms ECO Mode ↔ Inverter Mode TBD

DISPLAY LCD AUDIBLE ALARM Yes

DIMENSION WxHxD 530 x 800 x 1360 mm 600 x 800 x 1880 mm

NET WEIGHT 476kg 680kg

ENVIRONMENT Operating Temperature 0-30°C Noise Level <64dB @ 1 meter

INTERFACE RS232/USB Yes External Slot 2 mini-slots for SNMP/CMC/AS400 Card Emergency Power Off Yes

3PH - 04

Page 54: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

AC Inverter

TYPICAL APPLICATION

HYBRID INVERTER series • Ideal energy saving solution for home/office applications and serves as

long back-up UPS

• Reliable backup power supported by both solar system and battery bank

• Able to switch on/off external AC generator depending on the level of

solar power

• Batteries can be charged by both PV system and AC input

• Automatically switches between 9 operation modes to optimize the

energy consumption

• Built-in 20/35A battery charger

• Built-in MPPT* for optimized PV energy harvest

• Compliance with CE

ACI - 01

*MPPT: Maximum Power Point Tracker

Page 55: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

AC Inverter

MODEL Hybrid 5048E CAPACITY 5000VA/4200W

SOLAR INPUT

No. of MPPT 1 Max. Input Power 4500W Initial Feed-in Voltage 160VDC

Working Voltage Range 130-300VDC

Full-rating Voltage Range 185-300VDC

LINE MODE (AC mains are normal)

Input Voltage Waveform Sinewave (mains or generator)

Input Voltage Range 170-280VAC (normal range) 90-280VAC (generator/wide range)

Input Frequency Range 40-65Hz Output Voltage Waveform Same as input Output Short-circuit Protection Built-in 40A circuit breaker Efficiency (Line Mode) >95% @R-load

Transfer Time (AC↔DC) 10ms (normal range setting) 20ms (generator/wide range setting)

BATTERY MODE (AC mains are failed)

Nominal Battery Input Voltage 48VDC

Min. Startup Voltage1 40VDC

Output Voltage Waveform Sinewave Nominal Output Voltage 230VAC

Output Voltage Regulation 10% Output Frequency 50Hz / 60Hz 1Hz Efficiency >95%

BATTERY CHARGER

Supported Battery Type flooded lead-acid or sealed GEL/AGM lead-acid battery Nominal Battery Voltage 48VDC

Min. Battery Startup Voltage1 35VDC

Charger Current2 20/35A (user-configurable) DISPLAY 2 x LCD, 3 x LED indicators

PROTECTION DEGREE IP20 DIMENSION WxHxD 192x370x456 mm NET WEIGHT 17.2kg

ENVIRONMENT Operating Temperature 0-45℃ Noise Level 60dB

Note: 1. Hybrid 5048E can only be started up with battery (>35V). 2. Total capacity of external batteries shall be no less than 100AH.

ACI - 02

Page 56: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

AC Inverter

TYPICAL APPLICATION

INVEREX series

• Able to be configured to accept wider input voltage

• Rack/Tower dual set-up design

• Off-mode battery charging capability

• Built-in 10 Amp super charger for up to 100Ah battery

• Two-steps intelligent charging control to reduce the

recharging time

50

0 / 1

00

0 / 2

00

0

ACI - 03

Page 57: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

AC Inverter

MODEL INVEREX 500 INVEREX 1000-I INVEREX 1000-II INVEREX 2000-I CAPACITY 500VA/300W 1000VA/600W 1000VA/600W 2000VA/1200W

INPUT Input Voltage Range

170-280VAC (Normal Range) 90-280VAC (Wide Range)

Frequency Range >40Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.6 Nominal Output Voltage 220/230/240 VAC

Voltage Regulation -18%~10% Frequency Range ( Battery Mode ) 50/60 Hz 0.01Hz

Output Waveform Modified sine wave

EFFICIENCY AC to AC >95% DC to AC >80%

BATTERY

Battery Type Lead-acid battery Number of Internal Battery N/A Rated Battery Voltage 12V 24V Charging Current 10A

TRANSFER TIME Battery Mode ↔ Line Mode 15ms typical, 40ms max

DISPLAY LED AUDIBLE ALARM Yes DIMENSION WxHxD 255 X 80 X 224 mm NET WEIGHT 2 kg 2.1 kg 2.3 kg 2.5 kg

ENVIRONMENT Operating Temperature 0- 40°C Noise Level <50dB

ACI - 04

Page 58: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

AC Inverter

TYPICAL APPLICATION

INVEREX S series

• High-frequency switching technology for compact size and light weight

• Pure sine wave output for wide range of applications and harsh

environment

• High efficient(>90%) DC-to-AC conversion minimizing energy loss

• “Power Saving Mode” to conserve energy for less than 10W

• Easy-to-understand graphic LCD display

• Protections against Input low voltage / Overload / Short circuit / Low

battery alarm/ Input over voltage / Over temperature

50

48

E 3

02

4E

ACI - 05

Page 59: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

AC Inverter

MODEL INVEREX S 3024E INVEREX S 5048E CAPACITY 3000VA/2400W 5000VA/4200W

INPUT Input Voltage Range 90~280 VAC 170~280 VAC

Frequency Range 40~65Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.8 0.84 Nominal Output Voltage 230 VAC Voltage Regulation 10% Frequency Range ( Battery Mode ) 50/60 Hz 1Hz Output Waveform Pure sine wave Motor Load Capacity 1.5HP 2.5HP

EFFICIENCY AC to AC >95% DC to AC >90%

BATTERY

Battery Type Flooded/AGM/Gel lead-acid VRLA/ Flooded/AGM/Gel lead acid Number of Internal Battery N/A Rated Battery Voltage 24VDC 48VDC

Charging Current 20A 20A / 35A (user configurable) TRANSFER TIME Battery Mode ↔ Line Mode 10 ms typical, 15 ms max DISPLAY LCD AUDIBLE ALARM Yes DIMENSION WxHxD 268X76X323 mm 350X110X407 mm NET WEIGHT 4.9 kg 9 kg

ENVIRONMENT Operating Temperature 0- 45°C Noise Level ≦60dB

ACI - 06

Page 60: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

AC Inverter

TYPICAL APPLICATION

INVEREX Z series

• Designed for 110/120VAC AC grid system

• Able to be configured to accept wider input voltage

• Rack/Tower dual set-up design

• Off-mode battery charging capability

• Built-in 10 Amp super charger for up to 100Ah battery

• Two-steps intelligent charging control to reduce the

recharging time

50

0 / 1

00

0 / 2

00

0

ACI - 07

Page 61: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

AC Inverter

MODEL INVEREX Z 500 INVEREX Z 1000-I INVEREX Z 1000-II INVEREX Z 2000-I CAPACITY 500VA/300W 1000VA/600W 1000VA/600W 2000VA/1200W

INPUT Input Voltage Range

90-145VAC (Normal Range) 50-145VAC (Wide Range)

Frequency Range >40Hz Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.6 Nominal Output Voltage 220/230/240 VAC

Voltage Regulation -18%~10% Frequency Range ( Battery Mode ) 50/60 Hz 0.01Hz

Output Waveform Modified sine wave

EFFICIENCY AC to AC >95% DC to AC >80%

BATTERY

Battery Type Lead-acid battery Number of Internal Battery N/A Rated Battery Voltage 12V 24V Charging Current 10A

TRANSFER TIME Battery Mode ↔ Line Mode 15ms typical, 40ms max

DISPLAY LED AUDIBLE ALARM Yes DIMENSION WxHxD 255 X 80 X 224 mm NET WEIGHT 2 kg 2.1 kg 2.3 kg 2.5 kg

ENVIRONMENT Operating Temperature 0- 40°C Noise Level <50dB

ACI - 08

Page 62: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

AC Inverter

TYPICAL APPLICATION

INVEREX HD series • Ideal backup power solution for home / workplace

• Ready for appliances such as TV, stereos and lights

• High conversion efficiency (>95%) results in energy saving

• High output power factor (0.72-0.8)

• Easy-to-understand LCD and LED indicators

• Design for both stand and wall-mounted setup

• User-selectable charging current allows flexible battery configuration

• Intelligent battery charging control

• Protection against over-charging and over-loading

10

00

/ 20

00

ACI - 09

Page 63: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

AC Inverter

MODEL INVEREX HD 1000 INVEREX HD 2000 CAPACITY 1000VA/800W 2000VA/1440W

INPUT Input Voltage Range

170~280VAC (normal range) 90~280VAC (wide range)

Frequency Range Input Wiring Single phase with ground

OUTPUT

Output Power Factor 0.8 0.72 Nominal Output Voltage 230 VAC Voltage Regulation -18%~+10% Frequency Range ( Battery Mode ) 50/60 Hz 1% Output Waveform Modified sine wave

EFFICIENCY AC to AC >95% DC to AC >80%

BATTERY

Battery Type Lead-acid battery Number of Internal Battery N/A Rated Battery Voltage 12V 24V Charging Current 15A / 20A (user configurable) 10A

TRANSFER TIME Battery Mode ↔ Line Mode 15ms typical, 40ms max. DISPLAY LCD/LED AUDIBLE ALARM Yes DIMENSION WxHxD 220X87X252 mm NET WEIGHT 2.2 kg

ENVIRONMENT Operating Temperature 0- 50°C Noise Level <50dB

ACI - 10

Page 64: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

Solar Charger Controller

TYPICAL APPLICATION

KEY FEATURES SOLAR MATE series • High conversion efficiency

• Able to supply power to DC loads for extensive applications

• Built-in MPPT (Maximum Power Point Tracker) to optimize energy harvest

• Supports various types of battery with tailor-made charging profiles

• 3-stage battery charging control (bulk, absorption, and float charging)

• Overload and lightning protection

• Protection for reversed polarity of PV panel and batteries

• Real-time charging status and fault events are shown by LED indicators

12

/ 24

V

36

/ 48

V

SCC - 01

Page 65: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

Solar Battery Charger

Model Solar Mate 12/24V Solar Mate 36/48V Battery Voltage Setting (user configurable) 12VDC 24VDC 36VDC 48VDC

Input Voltage Range 15-55VDC 40-150VDC

Rated Charging Current 40 A 24A Load Current 15 A 7A Max. PV Input Voltage 55VDC 150VDC

Idle Current Consumption <10mA

Over Load Protection (DC load) 30 >5s 14A>5s 22.5A >20s 10.5A >20s 18.8A (de-rating) 8.8A (de-rating)

Bulk Charge 14.6 VDC (default) 29.2 VDC (default) 43.8 VDC (default) 58.4 VDC (default)

Float Charge 13.4 VDC (default) 26.8 VDC (default) 40.2 VDC (default) 53.6 VDC (default)

Over Charge Disconnection 14.8 VDC 29.6VDC 47.4 VDC 63.2VDC

Over Charge Recovery 13.6V 27.2V 42.0 VDC 56.0 VDC

Over Discharge Disconnection 10.8V 21.6V 32.4 VDC 43.2 VDC

Over Discharge Reconnection 12.3V 24.6V 36.9 VDC 49.2 VDC

Low Voltage Reconnect 13± 1 VDC 26.0± 2VDC 36.9 ± 0.3 VDC 49.2 ± 0.3 VDC

Low Voltage Disconnect 11.5± 1 VDC 23.0± 2VDC 32.4 ± 0.3 VDC 43.2 ± 0.3 VDC

Operating Temperature 0-40℃ 0-50℃ Cooling Method Natural cooling Protection Degree IP21 IP20 Terminal Wiring Size AWG # 8 AWG # 20~6 Dimension WxHxD 140 x 66 X 192 mm 220 X 311 X 124 mm

Net Weight 1.4 kg 5.4 kg

SCC - 02

Page 66: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

AVR

TYPICAL APPLICATION

KEY FEATURES HOSTA series • Provides high quality AC power to support sensitive equipment and

loads

• Automatically switches between buck and boost operation

• Wide input voltage range

• Auto-restart after AC mains’ recovery

• Easy-to-read LCD and LED indicators

• High efficiency design minimizes energy loss

• Provides over-temperature, short-circuited protection

10

00

AVR - 01

Page 67: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

AVR

MODEL HOSTA 1000 CAPACITY 600VA/600W

INPUT Nominal Input Voltage 220VAC

Nominal Frequency 50Hz Input Voltage Range 120~260VAC

OUTPUT

Nominal Output Voltage 220 VAC Boost 1 Mode Voltage Vin×1.1 Boost 2 Mode Voltage Vin×1.2 Boost 3 Mode Voltage Vin×1.3 Boost 4 Mode Voltage Vin×1.42 Buck Mode Voltage Vin×0.9 Output Frequency Same as Input Voltage Regulation (Line Mode) +8% / -30% @330W loading Output Power Factor 1

EFFICIENCY

Line Mode >98%

Boost Mode

Boost 1: 96% Boost 2: 94% Boost 3: 92% Boost 4: 84%

Buck Mode >96%

ENVIRONMENT Operating Temperature 0-50℃ Noise Level <35dB

DIMENSION WxHxD 200x80x135 mm NET WEIGHT 1.95kg

AVR - 02

Page 68: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

AVR

TYPICAL APPLICATION

KEY FEATURES VANDA series

• Provides high quality AC power to support sensitive equipment and loads

• Automatically switches between buck and boost operation

• Wide input voltage range

• High efficiency design minimizes energy loss

• Provides over-loading, over-temperature, over-voltage protection

10

00

/ 20

00

AVR - 03

Page 69: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

AVR

MODEL VANDA 1000 VANDA 2000 CAPACITY 1000VA/600W 2000VA/1200W

INPUT Nominal Input Voltage 220 VAC

Nominal Frequency 50 Hz Input Voltage Range 165-253 VAC

OUTPUT

Nominal Output Voltage 220 VAC

Boost2 Mode Voltage Vin×1.2

Boost1 Mode Voltage Vin×1.1 Buck Mode Voltage Vin×0.92 Output Frequency Same as Input Voltage Regulation (Line Mode) -10%~+6% Output Power Factor 0.6

EFFICIENCY Line Mode >98% Boost1/Boost2 >95% Buck >95%

ENVIRONMENT Operating Temperature 0-40℃ Noise Level < 50dB

DIMENSION WxHxD 111 x 135 x 215 mm NET WEIGHT 3.46 kg 4.18 kg

AVR - 04

Page 70: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

AVR

TYPICAL APPLICATION

KEY FEATURES IBERIS series • Provides high quality AC power to support sensitive equipment and

loads

• Automatically switches between buck and boost operation

• Wide input voltage range

• Easy-to-understand LED indicators

• High efficiency design minimizes energy loss

• Surge protection for phone/modem line

80

0 / 1

00

0 / 1

60

0 / 2

00

0

AVR - 05

Page 71: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

SPECIFICATION

AVR

MODEL IBERIS 800 IBERIS 1000 IBERIS 1600 IBERIS 2000 CAPACITY 800VA/400W 1000VA/500W 1600VA/800W 2000VA/1000W

INPUT Nominal Input Voltage 120/220 VAC

Nominal Frequency 50/60 Hz Input Voltage Range 80-138/180-288 VAC

OUTPUT Nominal Output Voltage 120/220 VAC

Output Frequency Same as Input Output Power Factor 0.5

EFFICIENCY Line Mode 95% Boost 92% Buck 92%

ENVIRONMENT Operating Temperature 0-40℃ Noise Level < 40dB

DIMENSION WxHxD 281 mm X 90 mm X 120 mm NET WEIGHT 4.18 kg

AVR - 06

Page 72: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Accessory

KEY FEATURES

KEY FEATURES

NMC Card

AS400 Card

• Provides voltage-free dry-contact signals for programmable controller

and management system

• Ideal to work with server, personal computer and workstation

• Support external alarm, fault indicator, status indicator, bypass and

remote shutdown

• Ideal monitoring solution enables user to monitor and control the status of UPS on web browser via internet

• Communicates with UPS and respond to Network Management System using SNMP (Simple Network Management Protocol)

• Supports RTC (Real-Time-Clock) • Supports software to shutdown server or client operating system safely

during the power failure

NMC: Network Management Card

CMC Card

• Easy solution for remote monitoring and control

• Converts the UPS RS232 signal new RS232 signal with specified address

• Converts the UPS RS232 signal into RS485 signal (4-wire, full-duplex)

• Provides a pair of RJ45 interface

CMC: Central Monitoring Card

ACC - 01

Page 73: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

KEY FEATURES

KEY FEATURES

Accessory

Mini NMC Card

Mini AS400 Card

• Provides voltage-free dry-contact signals for programmable controller

and management system

• Ideal to work with server, personal computer and workstation

• Support external alarm, fault indicator, status indicator, bypass and

remote shutdown

• Ideal monitoring solution enables user to monitor and control the

status of UPS on web browser via internet

• Communicates with UPS and respond to Network Management System

using SNMP (Simple Network Management Protocol)

• Supports RTC (Real-Time-Clock)

• Supports software to shutdown server or client operating system safely

during the power failure

• Network Management Card

Mini CMC Card

• Easy solution for remote monitoring and control

• Converts the UPS RS232 signal new RS232 signal with specified address

• Converts the UPS RS232 signal into RS485 signal (4-wire, full-duplex)

• Provides a pair of RJ45 interface

NMC: Network Management Card

CMC: Central Monitoring Card

ACC - 02

Page 74: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

Accessory

KEY FEATURES

KEY FEATURES

Relay Card

• Provides voltage-free dry-contact signals for programmable

controller and management system

• 5 output relay signals

• 1 input signal for remote on/off and UPS shutdown

• Configurable normal-open or normal-close signal

• Configurable delay time

USB/RS232 Card

EMP

EMP: Environmental Monitoring Probe

• Supports temperature and humidity sensors for remote environment

monitoring

• Works with NMC card to monitor the readings using web browser and

send notification when the reading exceeds pre-set limits

• Measures temperature from 0~70℃ and humidity from 10~90%

• Adds USB and RS232 ports on compatible UPS

• Enables the remote monitoring and control of UPS via the USB and

RS232 ports

• Compatible with monitoring software - Winpower

ACC - 03

Page 75: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

KEY FEATURES

KEY FEATURES

Accessory

External Charger

• Two models for different charging current: 8A and 20A

• 273V charging voltage

• 90% efficiency

• 3 LED indicators to show the charging modes and status

• Built-in fuse at AC input

ATS

• Serves as power source selector

• Back-feed protection

• Over-loading, short-circuit protection

• Supports RPO (Remote Power Off)

• Supports remote monitoring for input and output

ATS: Automatic Transfer Switch

ACC - 04

Page 76: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

Accessory

Name Part Number

USB/RS232 Card 730-80208-00P

AS400 Card (White) 730-50024-02P

AS400 Card (Black) 730-80135-00P

AS400SC Card 744-15568-00P

Mini AS400 card 730-80141-00P

Mini AS400 card 730-80197-00P

Relay Card 730-80302-00

Titan (Vista) 1-3K ● ● ○ Titan (Vista) 6-20K ● ● ○ Innova 1-3K ● ● ● Innova 6-10K ● ● ● Innova Combo 10-20K ● ● ● Innova RT 1-6K ● ● ● Innova RT 10K ● ● ● JAGA 1-3K ● ● Gripower Pro ● ● Claire 750-3000 ● Spring RT 1000-3000 ●

Name Part Number

CMC Card 730-80118-00P

Mini CMC Card 730-80100-00P

NMC Card 730-80348-00P

Mini NMC Card 730-80349-00P

EMP for NMC Card 744-A2460-00P

8A External Charger 730-80083-00P

12A External Charger 730-80084-00P

Titan (Vista) 1-3K ● ● ● Titan (Vista) 6-20K ● ● ● ● ● Innova 1-3K ● ● ● Innova 6-10K ● ● ● ● ● Innova Combo 10-20K ● ● ● Innova RT 1-6K ● ● ● Innova RT 10K ● ● ● ● ● JAGA 1-3K ● ● Gripower Pro ● ● ● Claire 750-3000 ● ● Spring RT 1000-3000 ● ●

○: not fully supported ACC - 05

COMPATIBILITY MATRIX

Page 77: UPS HYBRID INVERTER SOLAR CHARGER … Catalogue-V02-20141203.pdf · AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER ... •DSP design enables precise and reliable control

Copyright © 2014 Centralion Industrial Inc. All Rights Reserved.

• Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan •TEL: +886-2-2794-6363 • Fax: +886-2-6606-8711 • Website: www.centralion.com