Alarm Control Panels
Easy as 1, 2, 3
Special Performance
Features: Four-double or eight Zones selected on board
SMS (via PSTN) reports events & zone descriptionSupports few EasyKey Keypads in
Arm, Disarm, Zone bypass with Remote DTMFBuilt-in, Powerful Dialer; tune or voice alert
Remote Up & Download (service via PC)Central Station Communicator with Contact ID
Reporting to two Central StationsLog stores up to 250 events, 9 users codes
GSM ready for wireless alert and alarm backupCompatible with all of Av-Gad LCD Keypads Telephone Line monitor & Smokes Interface
any language
Arm, Disarm....and morevia any telephone
Use your PC for programming andservicing, remote or locally
Send to your mobile.
& zone descriptionas keypad display (programming not required)
SMS
Full events details
AV-707
Easy to install, asy to program, asy to sellE E
Av Series 3000
S M SHome 01
ALARM 03Zone 4
Kitchen PIR
Pro
-
Av-Gad's EasyLoader AV-3000Represents the state of the art for technology, friendly and reliable alarm system control panels for the security requirements of small and medium-size, commercial, residential and industrial installations.The versatile EasyLoader Series 3000 meets and even surpasses all requirements for reliability and maintainability and provides the added advantage of easy installation and user-friendly operation.
user
Series 3000 Control Panel Main Features: AV-3004, 4 zone (4 double zones + keypad panic zone). AV-3048, 8 zone (4x2 zones + keypad panic zone). Self test during power up Smart dialer with End User programmable Follow-Me feature Programmable Zone features: 24-Hours, Delayed, Follower, Fire.. 15 types AV-3004 operable with or without E.O.L resistors AV-3048 requires operating with E.O.L resistors Selectable Zone Bypass, few Home Modes Battery Test under load every hour and upon Arming. SMS at low battery Interfacing to smoke detectors 2 or 4 wires type. Requires AV-01 relay for Reset Series 3000 includes: Dialer to 6 numbers, Communicator 2 numbers, SMS to two
numbers (ETSI Standards), Modem Bell 103 for up and download from any Telephone or PC, Remote DTMF Commands (arming, disarming, bypass & more)
Keypads Main Features: Series 3000 alarm panels are compatible with LCD keypads Only 4 Wires, including Local Panic via keypad and tamper switch LCD Keypad Display clearly and reports Alarm Status by Zone,
Bypassed Zones, Alarm History per Zone, plus much more Private logo and zone description with internal dictionary Test Confirmation by Text, Like: chime, delay delete, Error in programming
Low battery, plus zone description: Entry Door, Kids Room 1, etc Individual Zone Bypass or Group of Zones at Home Mode LCD text is available in Spanish, French, German, Swedish and others Additional LEDs indicate Armed/Alarm, Zone Status Summary, Bypassed Zones,
24-Hours, Fire, Alarm-on, AC Fail and Program Now Fast and easy programming from keypad, local or Remote PC Few models available, Metalized, wide or long shape, extra keys model AV-707B
Alarm Outputs: High power AC or DC Siren output or PGM, with & without strobe light DC 13.6V fuse protected power supply and charger for SLA battery Keypad Data & strobe interfacing with MOSFET protectors PGM (2) outputs triggered by a number of different system events Dial out relay disconnects the PSTN line upon dialing SMS communicator via PSTN lines (SMS enabled PSTN lines)
Ordering Information:
SVM-40 voice module, AVG-14 or AVG-15 GSM backup
AV-3044 Pro,Keypads:Transformers:Communication:
4 or 8 zones, ABS enclosure. Compatible with LCD keypads AV-707, AV-707B, AV-706, AV-705 (economical keypad)
5003TER (for 220V), 5002TER (for 115V)
Technical Specifications Operating Temperature:
-5 to +60 deg. C Input Power:
16V AC Step-Down Transformer;1.2A 40 to 65 Hz
Auxiliary Power Output:13.6V-1.2A Regulated, Short & Overload circuit protection
Siren Output:Siren or Bell selectable. Horn Siren - 15Wat 8 Ohms; Bell Mode - 14V DC, 0.7A max.
Dialing:Pulse or DTMF DialingMeet R&TTE, CTR-21 and Austel directives
SMS Protocol (type 1 by Deutsche Telekom ): Fully compliant with the GSM SMS service as per ETSI ES 201 912. SMS decoding is DCS=0 (GSM Alphabet) 7 bits as pet ETSI TS 100 900
Remote Outputs:Programmable 200mA open-collector type
Battery Charging Current:550mA, current limitation
Standby Power Consumption:30mA without interfaced keypad
Remote Stations:Up to Three of AV-705, AV-706, AV-707 LCD keypad
Electronic Fuses (3):Auxiliary 12V, Siren, Battery
Housing:ABS box (metal is optional), dual tamper
Dimensions (cm):(H) 31, (D) 9, (W) 23 cm
Weight:AV-3044 Pro, 1.2 kg (6 per master box)