Upgraded Interferometer Overview System Performance · •The detector (SHM) measures the intensity...
Transcript of Upgraded Interferometer Overview System Performance · •The detector (SHM) measures the intensity...
Acknowledgements• USDOEgrantNo.DE-FG02-00ER54610
• M.C.Milleretal.,RevSci.Instrum.83,10E332(2012)
• Marushchenko et al., Comput.Phys.Commun.185,165(2014)
• Hansonetal.,Nucl.Fusion49,075031(2009)• I.H.Hutchinson,Prin.ofPlasmaDiagnostics(2e),CUP
TheCompactToroidalHybridExperiment
• CTHisa5field-periodtorsatrondesignedtoinvestigateplasmainstabilityanddisruptionsoverawiderangeofoperatingconditions
• ThehybridfeatureofCTHistheabilitytoaddtoroidalcurrent,whichgivessignificantcontroloverthetransformprofile.
DESIGNRo =0.75m
av =0.29m
ap ≤0.20m
Bo ≤0.7T
Ip ≤80kA
PECRH=15kWPOHM ~ 200kW
PLASMAPARAMETERSshottime~ 0.1s
ne ≤5x1019 m-3
Te ≤200eV
<b> ≤0.2%
0.02≤≤0.35
V3FITSensitivityAnalysis
• foragivendensityprofile,V3FITshowshow sensitivityofreconstructiondependsonthenewlocationsofthebeams
TRAVISBeamRefractionStudy
• beamdeflectiontendstobehighestwhereverthereisbothahigherdensityandastrongdensitygradient
• TRAVIScodewasusedtoanalyzepossiblebeamlocationstominimizethedeflectionofthebeamfromretro-reflector(δZ)
Summary
• interferometerupgradehasbeensuccessfullydesigned,builtanddemonstrated.
• newchannelisincorporatedinequilibriumreconstructions
• planningtousenewdensitymodeltoanalyzeverticalinstability
• performanceissuesofthenewchannelwillbeaddressedbyfurtherrefiningthefrequencymodulationprogram
SystemPerformance
• channel4line-integrateddensityconsistentwithotherchannelsassumingup-downsymmetricdischarge
• 4independentbeamsgivemoredetailsofshotevolution
• noiseisachallengeforthenewchannel.(4)Nowitiswell-controlled.
BASICS• Plasmaretardsmm-wavebeam~ densityà phasemodulation
• Thedetector(SHM)measurestheintensityoftheinterferencefringes
• Thetotal phasedelaywrittenintermsoftheline-averagedplasmadensity:
• 1fringeshiftà ∆𝜙%&'()* = 2𝜋 à ~ 3.0×104& electrons/m3
InterferometryinPlasmaDiagnosis
ADVANTAGES
• non-perturbativemeasurement
• subharmonicreferencelegfeedsdirectlyintomixer– easyalignmentofdetector
CHALLENGES
• refractionofbeamoutofretro-reflectorà lossofsignal
• rapidtransient-inducederrorsinfringecounting(fringejumps)
V3FITMulti-BeamComparison
Startedwiththeassumptionthatmoredataisbetter.
Compared3,4and5-beamconfigurations
• Weestimatedpotentialreductionintheerrorsinequilibriumreconstructioninexpandingsignalstoa4and5-beamsystem
• Computed“fractionalerror”(𝛼)basedonknownandreconstructeddensityprofiles
• mainresult isthereisverylittledifferencebetweenthe4-beamand5-beamsystemsintermsofreducingerrorsinreconstruction
𝛼 ≡∫ 𝑑𝑠|𝑛<=>?=(𝑠) − 𝑛CDE>=(𝑠)|4'
∫ 𝑑𝑠𝑛<=>?=(𝑠)4'
plasmadensity
[x10
18 m
-3]
shot#18102253
References
t=1.630sOhmicrise
t=1.650s
Ohmicplateau
shot#18102253
EquilibriumReconstruction
• firstequilibriumreconstructionsusingupgradedinterferometer basedonsimplelinesegmentmodelfordensity
Height(Z)[m]
majorradius(R)[m]
Height(Z)[m]
majorradius(R)[m]
n e(x10
18)[m
-3]
fluxcoordinate(s)
n e(x10
18)[m
-3]
fluxcoordinate(s)
UpgradedInterferometerOverviewMOTIVATION
• newconfigurationprovides2additionalindependentdiagnosticsignalswhichshouldprovidemuchimproveddensityprofileresolutionforstudyingMHDinstabilitiesanddisruptions
newSHMdetector
voltage-controlledoscillator
amplifier-multiplierchain
14.5 cm
7.3 cm
0.0 cm
-11.1 cm
chan 1
chan 2
chan 3
chan 4
10.2 cm
0.0 cm
-10.2 cm
mm-wavepowerline
parabolicmirror
Sub-HarmonicMixer
detectors
HDPEwindow
retroreflectors
chan 1
chan 2
chan 3
Improvementsinnewdesign• asymmetricpositionseliminateredundancy
• beamscoverhigherfractionofplasmavolume
• higherfrequencymitigatesdensitylimit
CTHspecialdesignfeaturesSubharmonicMixer(SHM)design• referencelegsupplieddirecttoSHMfacilitatesalignmentandreducesconversionloss
Double-passhorizontallaunch• allowssingle-portaccesstoplasma
Chirpingoffrequencycontrol• frequencymodulationrequiredforphaseshiftcalculationinsingle-sourceinterferometer
Limitationsoforiginaldesign• symmetricoff-axisbeamsareredundantdata
• beamscoversmallerfractionofplasmavolume
• double-passdesignimposesalimitonmaximumdensity
UpgradeModifications
• mm-wavebeamat280GHzand10mW
• Improvedbeamconfiguration
• beamrefractionanalysiswasdoneonthreegeneralclassesofprofiles- broad,peakedandhollow
• higherfrequencybeamhaslowerrefraction
• newhigherfbeamplacedwherebeamlossbydeflectionisminimizedforfullsystem
• signaleffectiveness(𝐸GH)isameasureofthesensitivityofmodelparameterstovariationsinagivensignal.
• RESULT - fullanalysisshowsbeamspacingprovidescoveragewithgoodsensitivityoverfullplasmavolumeforbroad,peakedandhollowdensityprofiles.
TheCTHCoilSet
𝐸GH ≡𝑑(𝑙𝑛𝜎HK)𝑑(𝑙𝑛𝜎G)
t=1.610sECRHphase
Height(Z)[m]
majorradius(R)[m]
n e(x10
16)[m
-3]
fluxcoordinate(s)
shot#18102253