RICH status report Transversity Meeting A March 05 -Jlab Detector Performances Possible upgrade.
Update on RICH Upgrade Simulations
description
Transcript of Update on RICH Upgrade Simulations
![Page 1: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/1.jpg)
1
Update on RICH Upgrade Simulations
S.Easo,16-10-2012
RICH Upgrade meeting
![Page 2: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/2.jpg)
2
Outline
• Feasibility of the two-RICH option for upgrade.
• Last meeting: Results from using current optics / ‘modified optics’ for RICH1
‘Modified optics’ suffered PID performance loss due to acceptance effects although it reduced the peak occupancy by 50%.
• This presentation:
Further modifications to the RICH1 optics to avoid acceptance effects
Comparison of PID performances
Plans
![Page 3: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/3.jpg)
3
Optics Modifications
• Spherical mirror ROC= 2710 3800 mm (same as version2)
• Spherical mirror tilt = 240 mrad (current optics ~ 315 mrad, version2 ~ 200 mrad)
• Flat mirror: mirror segment sizes increased by 30%, but kept the same location for edge nearest to the beampipe as in version2.
• Photodetector planes tilted accordingly.
Photon: angle of incidence on PMT plane.
Mean=38 mrad
• PMT modules 5 rows7 rows in each panel of RICH1.
Optics-Version3
![Page 4: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/4.jpg)
4
RICH1 Optics
Optics-Version3
![Page 5: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/5.jpg)
5
RICH1 – Optics verifications
Optics-Version3
Particle Gun at 280 310 mrad
![Page 6: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/6.jpg)
6
Optics-Version3Particle gun at 25 35 mrad
RICH1 Optics Verifications
![Page 7: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/7.jpg)
7
RICH1 Optics verifications
Cherenkov angle reconstructed in Particle gun events
Width=0.72 mrad
Optics Version3
RICH1 yieldMean=36
![Page 8: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/8.jpg)
8
Datasets and simulation options
• Gauss v42r1, Brunel v44r0
Luminosity cm-2 s-1
Beam Energy (TeV)
Spill Over Photo-Detector
Lumi2-S 2 x 10 32 3.5 No PMT-SBA
Lumi20-S 20 x 10 32 7 No PMT-SBA
• All PMT data with SBA-Borosilicate version of PMTs. All data without Aerogel
• Signal events of Bs ff for PID studies
• About 20 K events used for each option
Current-Optics RICH1- Spherical Mirror ROC=2710 mm
Rich1-Optics-Version3 RICH1-Spherical MirrorROC=3800 mm and optics tuning
![Page 9: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/9.jpg)
9
PID performance at Lumi2
This version of ‘new optics’ has better performancecompared to ‘current optics’.
Current-Optics
RICH1-Optics-Version3
![Page 10: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/10.jpg)
10
PID performance at Lumi20
Current-Optics
RICH1-Optics-Version3
This new optics has better performance.
![Page 11: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/11.jpg)
11
PID comparisons
Performance loss due to Lumi2 Lumi20 is mostly recovered by improved optics. (ie. ‘Red ’ marginally below the ‘black ’ ).
![Page 12: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/12.jpg)
12
dll_K > 0.0dll_K >4.0
Lumi20-S, Current Optics
dll_K >0.0dll_K > 4.0
Lumi2-S, Current optics
MeV MeV
MeV MeV
K K efficiency p misID probability
PID vs. Momentum
![Page 13: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/13.jpg)
13
dll_K >0.0
PID vs. Momentum Lumi2-S, RICH1-Optics-Version3
dll_K > 4.0
dll_K >0.0 dll_K > 4.0
Lumi20-S, RICH1-Optics-Version3
![Page 14: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/14.jpg)
14
Epilogue
• The number of PMTS 1920 2688 in RICH1 2688= 12*7*2*16
Possibilities to reduce this: (a) Have a sparse distribution of PMTs near the outer edges of the acceptance. May be tried to to see the effect on PID (b) Limit the acceptance to a smaller value.
• Rotating RICH1 : Not done yet.
• Number of scintillation hits in RICH2 : to be improved.
![Page 15: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/15.jpg)
15
Summary
Improvements in the optics configuration resulted in improving the PID performance.
Possibilities exist for further improvements in PID performance and to reduce the number of PMTS used.
![Page 16: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/16.jpg)
16
BACKUP SLIDES
![Page 17: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/17.jpg)
17
PID vs Angle
In all plots dll_K > 4.0
9.3GeV<P < 30 GeV
Lumi20-Smrad
9.3GeV<P < 30 GeV
Lumi2-S
mrad
K K efficiency p misID probability
9.3GeV<P < 30 GeV
Current Optics RICH1-Optics-Version3
mrad
mrad
![Page 18: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/18.jpg)
18
RICH1-Optics-Version3
![Page 19: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/19.jpg)
19
Resolutions from Brunel
RICH1-Optics-Version3
![Page 20: Update on RICH Upgrade Simulations](https://reader035.fdocuments.net/reader035/viewer/2022062810/56815ac6550346895dc8934a/html5/thumbnails/20.jpg)
20
P PT
Track polar angle
MeV MeV
mrad
Track Parameters
Tracks used in RICH PID algorithm
Lumi2-S
Current-Optics