Update on GEM-based Calorimetry for the Linear Collider

27
Update on GEM-based Calorimetry for the Linear Collider A.White 1/11/03 (for J.Yu, J.Li, M.Sosebee, S.Habib, V.Kaushik)

description

Update on GEM-based Calorimetry for the Linear Collider. White 1/11/03 (for J.Yu, J.Li, M.Sosebee, S.Habib, V.Kaushik). Summary of criteria for GEM-based LC Calorimetry. Thin sensitive/readout layer for compact calorimeter design - PowerPoint PPT Presentation

Transcript of Update on GEM-based Calorimetry for the Linear Collider

Page 1: Update on GEM-based Calorimetry for the Linear Collider

Update onGEM-based Calorimetryfor the Linear Collider

A.White 1/11/03(for J.Yu, J.Li, M.Sosebee,

S.Habib, V.Kaushik)

Page 2: Update on GEM-based Calorimetry for the Linear Collider

Summary of criteria for GEM-based LC Calorimetry

- Thin sensitive/readout layer for compact calorimeter design- Simple 1- or 2-level “hit” recording for energy flow algorithm use- On-board amplification/digitization/discrimination for digital readout – noise/cross-talk minimization- Flexible design for easy implementation of arbitrary “cell” size

Page 3: Update on GEM-based Calorimetry for the Linear Collider

- Modular design with easy module-to-module continuity for supplies, readout path- Digital readout from each cell- Pad design (to avoid x-y strip complications)- small cell size for good two/multiple track separation- high efficiency for MIPs in a cell- option for multiple thresholds

Criteria continued…

Page 4: Update on GEM-based Calorimetry for the Linear Collider

Design for DHCAL using Triple GEM

Ground to avoid cross-talk

Embeded onboard readout

Page 5: Update on GEM-based Calorimetry for the Linear Collider

UTA Approach to GEM/Calorimetry

Two-prong approach - Simulate, in detail, stack of GEM hadron calorimetry (see V.Kaushik’s talk) - Develop practical experience assembling a GEM foil based detector from scratch.

Page 6: Update on GEM-based Calorimetry for the Linear Collider

From CERN-open-2000-344, A. Sharma

Page 7: Update on GEM-based Calorimetry for the Linear Collider

From CERN GDD group

GEM gains

Page 8: Update on GEM-based Calorimetry for the Linear Collider

Double GEM schematic

From S.Bachmann et al. CERN-EP/2000-151

Page 9: Update on GEM-based Calorimetry for the Linear Collider

Areas of GEM related study GEM foil handling, testing, installation. GEM double layer structure design and implementation. HV distribution system design implementation. GEM anode pad design, variations, testing. Readout electronics trials Complete prototype assembly, testing.

Page 10: Update on GEM-based Calorimetry for the Linear Collider

GEM prototype assembly

Page 11: Update on GEM-based Calorimetry for the Linear Collider
Page 12: Update on GEM-based Calorimetry for the Linear Collider
Page 13: Update on GEM-based Calorimetry for the Linear Collider
Page 14: Update on GEM-based Calorimetry for the Linear Collider

GEM FOILS (testing)- Foils for prototype purchased from GDD group at CERN ($400 each – framed)- Initial experience: foils are fairly robust; we have so far only exposed them in clean room environment; care with human exposure!- Electrical testing: first test – HVPS with A meter -> discharge -> local damage to ~5 holes -> fix with copper etch locally.- nA level current monitoring -> easily reach 450V across foils in air – repeatable.

Page 15: Update on GEM-based Calorimetry for the Linear Collider

GEM FOILS (production)- Calorimeter and tracking groups in U.S. interested in GEM-based detectors.- Clearly U.S. source would be preferable.- Potential sources: 3M Thin Films, MIT ?, Louisiana Tech.?- Issues: - etching vs. micro-machining etc.? - only limited quantities needed for HEP - interest from medical imaging ? - hole size, shape, quality for HEP use?

Page 16: Update on GEM-based Calorimetry for the Linear Collider

Micrograph of GEM foil

From CERN GDD Group

Page 17: Update on GEM-based Calorimetry for the Linear Collider

 

Defects in chemically etched GEM foils, showing misshaped and missing holes. Taken from F. Fraga et al. NIM A442, 417, 2000

GEM foil issues

Page 18: Update on GEM-based Calorimetry for the Linear Collider

Detail of GEM foil hole

From CERN GDD Group

Page 19: Update on GEM-based Calorimetry for the Linear Collider

GEM amplification vs. metal hole size

from A. Sharma CERN OPEN-98-030

Page 20: Update on GEM-based Calorimetry for the Linear Collider

GEM test chamber ( J.Li, UTA )

Page 21: Update on GEM-based Calorimetry for the Linear Collider

GEM/MIP signal size- Double GEM ~2100V -> ~ Gain 3000- Ionization ~30 i.p./cm => 10 e- / MIP- This gives ~ 30,000 e- on an anode pad.- 30,000 e- = 5 fC- GEM signal timing ~20ns- Current 5fC/20ns = 0.25 A- Amplifier sensitivity 25 mV/A- Expect signals ~5mV for MIP through GEM

Page 22: Update on GEM-based Calorimetry for the Linear Collider
Page 23: Update on GEM-based Calorimetry for the Linear Collider
Page 24: Update on GEM-based Calorimetry for the Linear Collider
Page 25: Update on GEM-based Calorimetry for the Linear Collider
Page 26: Update on GEM-based Calorimetry for the Linear Collider

Anode pad

layout

Page 27: Update on GEM-based Calorimetry for the Linear Collider

GEM Prototype Status- GEM chamber assembled/re-assembled several times to optimize layer spacing, HV stability, ...- Initially large noise problems (from building) – now mainly suppressed through grounding, filtering, sheilding.- Testing 1) Cosmic rate is 0.1 Hz through ~6 cm2 pad 2) Source Cs-137 e- ~1 MeV vs. GEM board

- See signals … not yet uniquely attributable to GEM.