Electric Tankless Water Heaters Since 1966 INSTANT-FLOW® C-MICRO WATER HEATER WITH 0.20 GPM ACTIVATION FLOW RATE. Unlimited Hot Water. Unlimited Confidence. PATENT PENDING THE CM SERIES INSTANT-FLOW® C-MICRO ACTIVATES AT AN ULTRA LOW FLOW RATE OF 0.20 GALLONS (0.75 LITERS) PER MINUTE.

Transcript of Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow...

Page 1: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

Electric Tankless Water Heaters

Since 1966

INSTANT-FLOW® C-MICRO WATER HEATER WITH 0.20 GPM ACTIVATION FLOW RATE.

UnlimitedHot Water. Unlimited Confidence.

P A T E N T P E N D I N G

THE CM SERIES INSTANT-FLOW® C-MICRO ACTIVATES AT AN ULTRA LOW FLOW RATE OF 0.20 GALLONS (0.75 LITERS) PER MINUTE.

Page 2: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

CHRONOMITE’S CM SERIES INSTANT-FLOW® C-MICRO PROVIDES FAST AND RELIABLE HOT WATER AT ANY POINT OF USE, ALL WHILE REMAINING SEAMLESSLY INCONSPICUOUS.

INSTANT-FLOW® C-MICRO (CM SERIES)

Model No. 9153Neo-Metro Slab Edge with dyson airblade wash+dry

Page 3: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

IDEAL FOR COMMERCIAL, INDUSTRIAL AND RESIDENTIAL SINKS IN RESTROOMS AND KITCHENETTES. INSTANT-FLOW C-MICRO DELIVERS ENDLESS HOT WATER TO A VARIETY OF APPLICATIONS INCLUDING:

n OFFICE BUILDINGS

n SCHOOLS

n MANUFACTURING PLANTS

n HOMES

n RESTAURANTS

Instant-Flow® C-Micro maintains consistent and reliable hot water by

regulating water temperature 120 times per second!

No mixing valves means that scalding is eliminated, while activation at

only 0.2 gallons per minute saves time, money and energy.

Instant-flow® C-Micro activates at an ultra low flow rate of 0.20 Gallons

(0.75 Liters) per minute. There is no pressure and temperature valve

needed (unless required by code), saving time and money on installation

while providing an endless supply of reliable hot water.

APPLICATIONS

Page 4: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor
Page 5: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

CHRONOMITE CM SERIES INSTANT-FLOW® C-MICRO LOW ACTIVATION MODELS ARE MANUFACTURED TO PROVIDE RELIABLE HOT WATER AT THE POINT OF USE. THE HEATER ACTIVATES AT AN ULTRA LOW FLOW RATE OF 0.20 GALLONS (0.75 LITERS) PER MINUTE.

n Eliminates scalding—preset factory temperature with no mixing valves required

n Vandal-resistant, rugged cast aluminum housing (standard)

n Faucet flow controls are supplied with each unit. 3/8” compression fittings are supplied (standard)

n Minimum operating/activation flow rate: 0.20 gallons (0.75 liters) per minute

n Wattage: 1.44 to 9.60 kilowatt range (depending on model)

n Ideal applications include: commercial, industrial, residential, public lavatories, kitchen/bar sink

n Ideal for sensor/hands-free faucets with the 104°F (40°C) antiscald, 110°F ADA, and 120°F Health code—factory preset setting; no mixing valve needed

n Optional temperature adjustment dial—ADJ option

n Meets CAL GREEN low flow requirements—operates on low flow activation faucets - 0.2 GPM

n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute)

n Digital microprocessor technology

n Endless hot water

n Saves water and energy—activation at 0.2 GPM is 99% energy efficient

n Saves space – smallest foot print – 6-1/4” (H) x 9-5/8” (W) X 2-3/4” (D)

n 50% more energy efficient than traditional heaters—immediate response to changes in incoming water temperatures, pressures, and flow rate

n Maintains consistent water temperature—regulates water temperature 120 times per second

INSTANT-FLOW® C-MICRO FEATURES

Page 6: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

INSTANT-FLOW® C-MICRO PACKS A LARGE PUNCH WITH A SMALL FOOTPRINT. EACH UNIT SAVES VALUABLE SPACE BY REMAINING INCONSPICUOUS IN PLACEMENT UNDER SINKS AND COUNTERTOPS.

Convenient faucet flow controls are supplied with each Instant-Flow® C-Micro unit. 3/8” compression fittings come standard and are supplied on each unit.

THE SPACE SAVING DESIGN MEASURES AT: 6 1/4”(H) X 9 5/8”(W) X 2 3/4”(D)

Underneath a durable, vandal-resistant aluminum housing, internal nichrome heating coils and digital microprocessor technology provide ultra-quick response times for temperature variations at 120 times per second!

n HOUSING is fabricated from rugged cast aluminum

n ELEMENT assembly is fabricated from Celcon plastic

n HEATING COILS are nichrome

n FAUCET FLOW CONTROLS are supplied with each unit; 3/8” compression fittings are supplied (standard)

n MINIMUM OPERATING/ACTIVATION FLOW RATE:

0.20 Gallons (0.75 liters) per Minute

n WATTAGE:1.44 to 9.60 Kilowatt Range (depending on model)

2 3/4”

6 1/4”

MAXIMIZE OUTPUT.MINIMIZE SPACE.

T E M P E R A T U R E A D J U S T M E N T K N O B L O C A T E D I N S I D E U N D E R C O V E R . ( - A D J O P T I O N )

Page 7: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

HOW IT WORKS

6 1/4”

S E L F C L E A N I N GW AT E R W A Y S

S TA I N L E S S S T E E LH E AT I N G C O I L S

D I F F E R E N T I A L P R E S S U R EF L O W A C T I V AT E D S W I T C H

E L E C T R I C A L C O N N E C T I O N T E R M I N A L S

C O N D U I T A C C E S S H O L E

C O L D W AT E R I N L E T

H O T W AT E R O U T L E T

M O U N T I N GF L A N G E

1

THE COSTLY CONVENTIONAL WAY

A TYPICAL REMOTE LAVATORY INSTALLATION

THE ECONOMICAL CHRONOMITE WAY

Page 8: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

Inlet Temp: 37° F

Model GPM UsageCM-30L/120 0.37 WFCM-20L/208 0.42 WF CM-30L/208 0.64 WF, FCM-40L/208 0.85 WF, FCM-15L/240 0.37 WFCM-20L/240 0.49 WFCM-30L/240 0.73 WF, FCM-40L/240 0.98 WF, FCM-15L/277 0.42 WF, CM-20L/277 0.56 WF, FCM-30L/277 0.85 WF, F

Inlet Temp:42° F

Model GPM Usage

CM-30L/120 0.40 WFCM-20L/208 0.46 WF, FCM-30L/208 0.69 WFCM-40L/208 0.92 WF, FCM-15L/240 0.40 WFCM-20L/240 0.53 WF, FCM-30L/240 0.79 WF, FCM-40L/240 1.06 WF, F, KF, DW, WMCM-12L/277 0.37 WFCM-15L/277 0.46 WFCM-20L/277 0.61 WF, FCM-30L/277 0.91 WF, F

Inlet Temp: 47° F

Model GPM UsageCM-30L/120 0.43 WFCM-15L/208 0.37 WF CM-20L/208 0.50 WF, FCM-30L/208 0.75 WF, F CM-40L/208 1.00 WF, F, KF, DW, WMCM-12L/240 0.35 WF CM-15L/240 0.43 WF CM-20L/240 0.58 WF, FCM-30L/240 0.86 WF, FCM-40L/240 1.15 WF, F, KF, DW, WMCM-12L/277 0.40 WF CM-15L/277 0.50 WF, F CM-20L/277 0.66 WF, F CM-30L/277 0.99 WF, F

77726762575247423735

AVERAGE GROUNDTEMPERATURE

GROUND WATER TEMPERATURES REFER TO WATER STORED OUTSIDE AND MANY NOT ACCURATELY REFLECT THE SOURCE.

*Results based on outlet temperature of 104°F

APPLICATIONS USAGE LEGEND

FLOW RATE GPM*

Water saver faucet/sink WF 0.35Standard faucet/sink F 0.5Kitchen Faucet/sink KF 1Water saver Shower S 1.5Standard shower SS 2Dishwasher DW 1.0-2.0Washing Machine WM 1.0-1.5

Inlet Temp: 52° F

Model GPM UsageCM-30L/120 0.47 WFCM-15L/208 0.41 WFCM-20L/208 0.55 WF, FCM-30L/208 0.82 WF, FCM-40L/208 1.09 WF, F, KF, DW, WMCM-12L/240 0.38 WFCM-15L/240 0.47 WFCM-20L/240 0.63 WF, FCM-30L/240 0.95 WF, FCM-40L/240 1.26 WF, F, KF, DW, WMCM-12L/277 0.44 WFCM-15L/277 0.55 WF, FCM-20L/277 0.73 WF, FCM-30L/277 1.09 WF, F, KF, DW, WM

Inlet Temp: 57° F

Model GPM UsageCM-30L/120 0.52 WF, FCM-20L/120 0.35 WFCM-12L/208 0.36 WFCM-15L/208 0.45 WFCM-20L/208 0.60 WF, F CM-30L/208 0.91 WF, FCM-40L/208 1.21 WF, F, KF, DW, WMCM-12L/240 0.42 WF CM-15L/240 0.52 WF, FCM-20L/240 0.70 WF, FCM-30L/240 1.05 WF, F, KF, DW, WMCM-40L/240 1.40 WF, F, KF, DW, WMCM-12L/277 0.48 WFCM-15L/277 0.60 WF, FCM-20L/277 0.81 WF, FCM-30L/277 1.21 WF, F, KF, DW, WM

THERE ARE SOME BASIC QUESTIONS YOU SHOULD ASK WHEN DECIDING ON A CHRONOMITE ELECTRIC TANKLESS WATER HEATER:

1. How cold is your inlet water temperature in the winter?

2. What is the flow rate and gallons per minute you need to supply your hot water demand?

3. Look at the heater models under the inlet temp for your region and select a heater that is equal to or greater than the flow rate GPM for your application.

Page 9: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

Inlet Temp: 62° F

Model GPM UsageCM-20L/120 0.39 WFCM-30L/120 0.59 WF, FCM-12L/208 0.41 WFCM-15L/208 0.51 WF, FCM-20L/208 0.68 WF, FCM-30L/208 1.01 WF, F, KF, DW, WMCM-40L/208 1.35 WF, F, KF, DW, WMCM-12L/240 0.47 WFCM-15L/240 0.59 WF, FCM-20L/240 0.78 WF, F CM-30L/240 1.17 WF, F, KF, DW, WM CM-40L/240 1.56 WF, F, KF, DW, WM, S CM-12L/277 0.54 WF, FCM-15L/277 0.67 WF, F CM-20L/277 0.90 WF, F CM-30L/277 1.35 WF, F, KF, DW, WM

Inlet Temp: 72° F

Model GPM UsageCM-15L/120 0.38 WFCM-20L/120 0.51 WF, FCM-30L/120 0.77 WF, FCM-12L/208 0.53 WF, FCM-15L/208 0.67 WF, FCM-20L/208 0.89 WF, FCM-30L/208 1.33 WF, F, KF, DW, WMCM-40L/208 1.78 WF, F, KF, DW, WM, SCM-12L/240 0.61 WF, FCM-15L/240 0.77 WF, FCM-20L/240 1.02 WF, F, KF, DW, WMCM-30L/240 1.54 WF, F, KF, DW, WM, SCM-40L/240 2.05 WF, F, KF, DW, WM, S, SSCM-12L/277 0.71 WF, FCM-15L/277 0.89 WF, FCM-20L/277 1.18 WF, F, KF, DW, WMCM-30L/277 1.77 WF, F, KF, DW, WM, S

Inlet Temp: 67° F

Model GPM UsageCM-20L/120 0.44 WFCM-30L/120 0.66 WF, FCM-12L/208 0.46 WFCM-15L/208 0.58 WF, FCM-20L/208 0.77 WF, FCM-30L/208 1.15 WF, F, KF, DW, WMCM-40L/208 1.54 WF, F, KF, DW,WM, SCM-12L/240 0.53 WF, FCM-15L/240 0.66 WF, FCM-20L/240 0.89 WF, FCM-30L/240 1.33 WF, F, KF, DW, WMCM-40L/240 1.77 WF, F, KF, DW, WM, SCM-12L/277 0.61 WF, FCM-15L/277 0.77 WF, FCM-20L/277 1.02 WF, F, KF, DW, WMCM-30L/277 1.53 WF, F, KF, DW, WM, S

Inlet Temp: 77° F

Model GPM UsageCM-12L/120 0.36 WFCM-15L/120 0.46 WFCM-20L/120 0.61 WF, FCM-30L/120 0.91 WF, FCM-12L/208 0.63 WF, FCM-15L/208 0.79 WF, FCM-20L/208 1.05 WF, F, KF, DW, WMCM-30L/208 1.58 WF, F, KF, DW, WM, SCM-40L/208 2.10 WF, F, KF, DW, WM, S, SSCM-12L/240 0.73 WF, FCM-15L/240 0.91 WF, FCM-20L/240 1.21 WF, F, KF, DW, WMCM-30L/240 1.82 WF, F, KF, DW, WM, SCM-40L/240 2.43 WF, F, KF, DW, WM, S, SSCM-12L/277 0.84 WF, FCM-15L/277 1.05 WF, F, KF, DW, WMCM-20L/277 1.40 WF, F, KF, DW, WMCM-30L/277 2.10 WF, F, KF, DW, WM, S, SS

Page 10: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

SELECT YOUR MODELC H R O N O M I T E A C T I V AT I O N

G P M V O LT S K W A M P S 9 0 °C W I R E

°F T E M P R I S E @ . 3 5 G P M

°F T E M P R I S E @ . 5 G P M

°F T E M P R I S E @ 1 . 0 G P M

°F T E M P R I S E @ 1 . 5 G P M

°F T E M P R I S E @ 2 . 0 G P M

C M - 1 2 L / 1 2 0 0 . 2 1 2 0 1 . 4 4 1 2 1 4 A W G 2 8 2 0 - - - - - - - - -

C M - 1 5 L / 1 2 0 0 . 2 1 2 0 1 . 8 0 1 5 1 4 A W G 3 5 2 5 - - - - - - - - -

C M - 2 0 L / 1 2 0 0 . 2 1 2 0 2 . 4 0 2 0 1 2 A W G 4 7 3 3 - - - - - - - - -

C M - 3 0 L / 1 2 0 0 . 2 1 2 0 3 . 6 0 3 0 1 0 A W G 7 0 4 9 2 5 - - - - - -

C M - 1 2 L / 2 0 8 0 . 2 2 0 8 2 . 5 0 1 2 1 4 A W G 4 9 3 4 - - - - - - - - -

C M - 1 5 L / 2 0 8 0 . 2 2 0 8 3 .1 2 1 5 1 4 A W G 6 1 4 3 2 1 - - - - - -

C M - 2 0 L / 2 0 8 0 . 2 2 0 8 4 .1 6 2 0 1 2 A W G 8 1 5 7 2 8 - - - - - -

C M - 3 0 L / 2 0 8 0 . 2 2 0 8 6 . 2 4 3 0 1 0 A W G 9 0 + 8 5 4 3 2 8 2 1

C M - 4 0 L / 2 0 8 0 . 2 2 0 8 8 . 3 2 4 0 8 A W G 9 0 + 9 0 + 5 7 3 8 2 8

C M - 1 2 L / 2 4 0 0 . 2 2 4 0 2 . 8 8 1 2 1 4 A W G 5 6 3 9 2 0 - - - - - -

C M - 1 5 L / 2 4 0 0 . 2 2 4 0 3 . 6 0 1 5 1 4 A W G 7 0 4 9 2 5 - - - - - -

C M - 2 0 L / 2 4 0 0 . 2 2 4 0 4 . 8 0 2 0 1 2 A W G 9 0 + 6 6 3 3 2 2 - - -

C M - 3 0 L / 2 4 0 0 . 2 2 4 0 7. 2 0 3 0 1 0 A W G 9 0 + 9 0 + 4 9 3 3 2 5

C M - 4 0 L / 2 4 0 0 . 2 2 4 0 9 . 6 0 4 0 8 A W G 9 0 + 9 0 + 6 6 4 4 3 3

C M - 1 2 L / 2 7 7 0 . 2 2 7 7 3 . 3 2 1 2 1 4 A W G 6 5 4 5 2 3 - - - - - -

C M - 1 5 L / 2 7 7 0 . 2 2 7 7 4 .1 5 1 5 1 4 A W G 8 1 5 7 2 8 - - - - - -

C M - 2 0 L / 2 7 7 0 . 2 2 7 7 5 . 5 4 2 0 1 2 A W G 9 0 + 7 6 3 8 2 5 - - -

C M - 3 0 L / 2 7 7 0 . 2 2 7 7 8 . 3 1 3 0 1 0 A W G 9 0 + 9 0 + 5 7 3 8 2 8

+ = A B O V E 9 0 D E G R E E S N O T E : A L L H E AT E R S L I M I T E D T O F A C T O R Y S E T M A X T E M P E R AT U R E

Page 11: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

C H R O N O M I T E A C T I V AT I O NG P M V O LT S K W A M P S 9 0 °C

W I R E°F T E M P R I S E

@ . 3 5 G P M°F T E M P R I S E

@ . 5 G P M°F T E M P R I S E

@ 1 . 0 G P M°F T E M P R I S E

@ 1 . 5 G P M°F T E M P R I S E

@ 2 . 0 G P M

C M - 1 2 L / 1 2 0 0 . 2 1 2 0 1 . 4 4 1 2 1 4 A W G 2 8 2 0 - - - - - - - - -

C M - 1 5 L / 1 2 0 0 . 2 1 2 0 1 . 8 0 1 5 1 4 A W G 3 5 2 5 - - - - - - - - -

C M - 2 0 L / 1 2 0 0 . 2 1 2 0 2 . 4 0 2 0 1 2 A W G 4 7 3 3 - - - - - - - - -

C M - 3 0 L / 1 2 0 0 . 2 1 2 0 3 . 6 0 3 0 1 0 A W G 7 0 4 9 2 5 - - - - - -

C M - 1 2 L / 2 0 8 0 . 2 2 0 8 2 . 5 0 1 2 1 4 A W G 4 9 3 4 - - - - - - - - -

C M - 1 5 L / 2 0 8 0 . 2 2 0 8 3 .1 2 1 5 1 4 A W G 6 1 4 3 2 1 - - - - - -

C M - 2 0 L / 2 0 8 0 . 2 2 0 8 4 .1 6 2 0 1 2 A W G 8 1 5 7 2 8 - - - - - -

C M - 3 0 L / 2 0 8 0 . 2 2 0 8 6 . 2 4 3 0 1 0 A W G 9 0 + 8 5 4 3 2 8 2 1

C M - 4 0 L / 2 0 8 0 . 2 2 0 8 8 . 3 2 4 0 8 A W G 9 0 + 9 0 + 5 7 3 8 2 8

C M - 1 2 L / 2 4 0 0 . 2 2 4 0 2 . 8 8 1 2 1 4 A W G 5 6 3 9 2 0 - - - - - -

C M - 1 5 L / 2 4 0 0 . 2 2 4 0 3 . 6 0 1 5 1 4 A W G 7 0 4 9 2 5 - - - - - -

C M - 2 0 L / 2 4 0 0 . 2 2 4 0 4 . 8 0 2 0 1 2 A W G 9 0 + 6 6 3 3 2 2 - - -

C M - 3 0 L / 2 4 0 0 . 2 2 4 0 7. 2 0 3 0 1 0 A W G 9 0 + 9 0 + 4 9 3 3 2 5

C M - 4 0 L / 2 4 0 0 . 2 2 4 0 9 . 6 0 4 0 8 A W G 9 0 + 9 0 + 6 6 4 4 3 3

C M - 1 2 L / 2 7 7 0 . 2 2 7 7 3 . 3 2 1 2 1 4 A W G 6 5 4 5 2 3 - - - - - -

C M - 1 5 L / 2 7 7 0 . 2 2 7 7 4 .1 5 1 5 1 4 A W G 8 1 5 7 2 8 - - - - - -

C M - 2 0 L / 2 7 7 0 . 2 2 7 7 5 . 5 4 2 0 1 2 A W G 9 0 + 7 6 3 8 2 5 - - -

C M - 3 0 L / 2 7 7 0 . 2 2 7 7 8 . 3 1 3 0 1 0 A W G 9 0 + 9 0 + 5 7 3 8 2 8

+ = A B O V E 9 0 D E G R E E S N O T E : A L L H E AT E R S L I M I T E D T O F A C T O R Y S E T M A X T E M P E R AT U R E

Page 12: Unlimited Hot Water. Unlimited Confidence....activation faucets - 0.2 GPM n Meets LEED v4 low flow requirements (lower than 0.4 gallons or 1.5 liter per minute) n Digital microprocessor

acornsafety.com 1

17451 Hurley Street • City of Industry, CA 91744 United States(800) 447-4962 • www.chronomite.com

Font used: BEBAS NEUE

MORRIS INTERNATIONAL ME FZE

Est. 1946

Est. 1989

Est. 1853

Est. 1937

Est. 2014

Est. 2013

Est. 2015

Est. 1945

Est. 1953

Est. 1945

Est. 1990

Est. 2008

Est. 2013Est. 2014

Est. 1989

Est. 2015

Est. 1995

Est. 1958

Est. 1972

Est. 1966

Est. 1926

Est. 1954

Est. 1984 Est. 1953

Est. 1998

Est. 2017

L 1 0 0 1 4 1 21 1 1 8