University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria...

102
Facilities Management | Department of Facilities Planning July 2018 University of Maryland College Park Campus Entrance Door Design Guidelines UPDATE

Transcript of University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria...

Page 1: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

Facilities Management | Department of Facilities Planning

July 2018

University of Maryland College Park Campus Entrance Door Design Guidelines

UPDATE

Page 2: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement
Page 3: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

Objectives Key Stakeholders Development Of CriteriaIssues, Challenges & Mistakes to be avoidedCampus Map Of Key BuildingsDesign Criteria MatrixCase Study Example 1: Edward St. John Learning and Teaching CenterCase Study Example 2: Plant SciencesTypical Details Typical Section At Building EntryTypical Raised Panel Door – ElevationsTypical Raised Panel Door – Enlarged PlansElevation Showing Typical Door Hardware – Double DoorElevation Showing Typical Door Hardware – Single DoorBuilding Color PaletteAcademic/Administrative BuildingsMatrix – Traditional BuildingsA1-T-ADA Academic Traditional Primary ADA EntryA1-T-TA Academic Traditional Primary EntryA1-T-TB Academic Traditional Primary EntryA2-T Academic Traditional Secondary EntryA3-TA Academic Traditional Tertiary Single EntryA3-TB Academic Traditional Service EntryMatrix - Traditional | Mid Century Modern BuildingsA1-M Academic Mid-Century Primary EntryA2-M Academic Mid-Century Secondary EntryA3-M Academic Contemporary Tertiary EntryMatrix - Traditional | Mid Century Modern | Contemporary Buildings A1-C Academic Contemporary Primary EntryA2-C-ADA Academic Contemporary ADA EntryA3-C Academic Contemporary Tertiary EntryAssembly/Events BuildingsMatrix - Traditional BuildingsE1-T Assembly & Events Traditional Primary EntryE1-T-ADA Assembly & Events Traditional Primary EntryE2-T Assembly & Events Traditional Secondary EntryE3-T Assembly & Events Traditional Tertiary EntryMatrix - All E1-M Assembly & Events Mid-Cent. Modern Primary EntryE2-M Assembly & Events Mid-Cent. Modern Secondary EntryE3-M Assembly & Events Mid-Cent. Modern Tertiary EntryResidential BuildingsMatrix -Traditional Residential BuildingsR1-T Residential Traditional Primary EntryR1-T-ADA Residential Traditional ADA EntryR1-T-Greek Residential Traditional Primary Greek House EntryR2-T Residential Traditional Secondary EntryR2-T-Greek Residential Traditional Secondary EntryR3-T Residential Traditional Tertiary EntryR3-T-Greek Residential Traditional Tertiary EntryMatrix - All R1-M-ADA Residential Mid-Century Primary ADA EntryR2-M Residential Mid-Century Secondary EntryR2a-M Residential Mid-Century Secondary Entry 2R3-M Residential Mid-Century Tertiary EntryFlowchart - Procedure For Exterior Doors

030506081012141618

25

55

73

98

Contents

Page 4: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

2 University of Maryland | Entrance Door Criteria

Page 5: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 3

“The preparation of Design Criteria for the variety of Entrance Doors, both replacement and new doors for selected buildings at the University” that will:

1. Serve to develop a prototypical range of solutions that will streamline the process and create consistency for entry door replacement by Facilities Management and the Department of Residential Facilities, including consultants’ design of new entrance doors for new facilities

2. Provide new guidelines for the Design Criteria and Facilities Standards (DCFS)

Objectives

Page 6: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

4 University of Maryland | Entrance Door Criteria

Page 7: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 5

Department of Planning & ConstructionWilliam Olen – Executive DirectorThomas Bunting – Associate Director, Design ServicesJocelyn Joiner Fleming – Assistant Director, Design Technical ServicesMark Green – Architect, Technical Support

Facilities PlanningBrenda Testa – Former Director William Mallari – Interim Director, Project ManagerDaniel Hayes – Planner, Campus Development

Department of Operations & MaintenanceJack Baker – Executive Director Rich Nickels – Assistant Director, Facilities Maintenance ProgramsRich Wilson – Program Manager, Exteriors

Key Stakeholders

Facilities Management Departments

Department of Public SafetyMark McGuigan – Coordinator, Building Security SystemsMarco Baker – Electronic Technician, Building Security Systems

Department of Residential Facilities Jon Dooley – Director Gregg Feige – Assistant DirectorJohn Kim-Norris – Residential FacilitiesTim Wheeler, Senior Manager, MaintenancePatrick Rhodes, Assistant to the Assistant Director, Residential Facilities

Ayers Saint GrossRosalie Tilghman – Project ArchitectRobert Claiborne – Architect & Historic ConsultantDavid Moore – Allegion PLC, Hardware ConsultantRandy Jump – Allegion PLC, Hardware Consultant

Page 8: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

6 University of Maryland | Entrance Door Criteria

Development and Consensus BuildingThe need for a comprehensive study of existing conditions on campus was identified by the Department of Design and Construction in 2014. Ayers Saint Gross was engaged to survey conditions, interview stakeholders and provide a set of recommendations based on the findings of this study. The study was conducted in two stages. The following flowchart highlights the steps taken and groups consulted in creating this set of documents. A separate flowchart illustrating the process for replacement of existing doors on campus is found at the conclusion of this report. An impetus for this study is the need to identify entrances that are required to be made ADA accessible. The Americans with Disabilities Act was signed into law in 1990; thus it can be assumed entrances of all buildings constructed after that date are found to be in compliance with ADA guidelines. It is in the classification of those entrances constructed before 1990 where the ADA designation is required.

Development Of Criteria

STAGE I

STAKEHOLDERSIssues & ProblemsLessons Learned

Suggested Examples

PROJECT MANAGER

ARCHITECTField VerificationDraft Examples

ALRB April 10,2015Include StakeholderReview & Comment

ARCHITECTFinalize List of Examples

Add Contextual Information

PROJECT MANAGER

ALRB August 28,2015

Page 9: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 7

STAGE II

HARDWARE CONSULTANT

HISTORICALARCHITECTURAL

CONSULTANT

STAKEHOLDERS PROJECT MANAGER

ARCHITECT

ALRB October 7, 2016

ARCHITECT DELIVERABLES

INCORPORATE INTO DCFS

Page 10: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

8 University of Maryland | Entrance Door Criteria

Issues, Challenges and Mistakes to Avoid

036 Plant Sciences• Finish deterioration, staining, delamination• Review auto-operator leaf designation,

breaks frequently• No available warranty• Replacement doors not readily available

415 Physical Sciences• Door swing sticks to adjacent entry soffit• Separation of door joints• Atypical door height & weight stresses

hardware

• Building site, entrance location and period of development• Entrance Type: Primary / ADA / Secondary / Tertiary• Door Types and Materials• Design, Operational and Maintenance Criteria

Each campus building entrance presents a unique situation with a matrix of criteria and issues to address and reconcile:

Examples Include:

Page 11: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 9

039 Van Munching• Closers not functioning• Doors will not secure to removable mullions• Water infiltration at threshold

231 Microbiology • Mixed materials• Undersized to entryway• Slab displacement• Not meeting ADA requirement

091 Chemistry • Fiberglass Reinforced Plastic (FRP) not

preferred• Inconsistent design

Page 12: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

10 University of Maryland | Entrance Door Criteria

0’ 250’ 500’

096

227 224415

098

142

223

083090

225

092

115

081406

405

089

003

088

091

084

082

036

147

144

231232163

162

143

146

141

140

034

073062

064

035

060

061

063

051

059

042

048

043

040

038

037

047

044

046

009

031

030

022

015

017

021

016014

029

023

028

019 032

008

076

052

077078

071

079

080 004

138

137 136 135 134

133

132

131

130129128127

126

007

139

054

237

099121

122259

256

258

254

254

253

Campus Map

Service BuildingRitchie ColiseumPocomoke Bldg.Annapolis Hall Memorial ChapelHarford HallCalvert HallBaltimore HallCecil HallSatellite Central Utilities BldgPrince George’s HallKent HallWashington HallHoward HallFrederick HallTalbot HallGarrett HallMontgomery HallJimenezMcKeldin LibraryPlant SciencesShoemaker Bldg.LeFrakVan MunchingMorrillTydingsTaliaferroSkinnerMarie MountWoodsF. S. KeyWorcester HallClarence M.Mitchell, Jr. Bldg.PreinkertChincoteagueAnne Arundel HallQueen Anne’s HallSt. Mary’s HallSomerset HallDorchester HallLeeH.J. PattersonSymons HallMain Administration

Reckord ArmoryVisitor CenterRossborough InnWind TunnelToll PhysicsJ.M PattersonMathGlenn L. MartinEngineering Laboratory BldgChem. & Nuclear EngineeringChemistryPotomacCambridge HallCentervilleBel Air HallA. V. WilliamsChestertown HallCumberland HallFraternity RowHealth CenterTawesAnimal ScienceBenjaminBiology-PsychologyParren J.Mitchell Art-SociologyHornbake LibraryColeStampEnergy Research FacilityComp. & Space ScienceKim EngineeringJullMicrobiologyNyumburu Cultural CenterGeologyDenton HallEaston HallElkton HallEllicott Hall Hagerstown HallLa Plata HallSatellite Central Utilities BldgCSICPhysical Sciences

003 004 007008009014015016017019021 022023028029030031032034035036037038039040042043044046047048051052054059060061062063064071073076077

078079080081082083084088089090091092096098099115121122

126-139140141142143144146147162163223224225227231232237252253254256258259405406415

Building Entrances Addressed in this Study:

LEGEND

PRIMARY PATHWAY

ADDRESS ALL BUILDING ENTRANCES WITHIN PRIORITY ZONE

ADDRESS ALL BUILDING ENTRANCES

SPECIAL CONSIDERATION TO DOORS FACING PRIMARY PATHWAY

PRIORITY ZONE

Page 13: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 11

0’ 250’ 500’

096

227 224415

098

142

223

083090

225

092

115

081406

405

089

003

088

091

084

082

036

147

144

231232163

162

143

146

141

140

034

073062

064

035

060

061

063

051

059

042

048

043

040

038

037

047

044

046

009

031

030

022

015

017

021

016014

029

023

028

019 032

008

076

052

077078

071

079

080 004

138

137 136 135 134

133

132

131

130129128127

126

007

139

054

237

099121

122259

256

258

254

254

253

Page 14: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

12 University of Maryland | Entrance Door Criteria

Design Criteria Matrix

Separate matrices were created to classify entrance types at the intersection of different criteria such as entrance priority and period of development. A broad spectrum of criteria, as well as feedback from ALRB and stakeholders, was considered before arriving at the recommendations in this report. A breakdown of criteria is listed below:

• Building Site & Entrance Location: site specific conditions• Period of Development: Traditional, Mid-Century Modern; Contemporary• Entrance & Door Type: Primary / Secondary / Tertiary• Design, Operational and Maintenance Criteria:

- Aesthetics (original design and historic preservation considerations) - Entry Systems, Door Types and Function - Materials and Hardware (includes transoms, sidelights, louvers) - Life Safety and Security - Universal Access and ADA - Maintenance; Repair and replacement - Sustainability Considerations - Costs: initial; maintenance - repair and replacement

Building Types & Criteria

Page 15: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 13

Entrance Type: Primary - ADATraditionalSymons Hall 076

Entrance Type: Primary TraditionalHJ Patterson 073

Entrance Type: Primary Mid-Century Modern / ContemporaryParren J. Mitchell 146

Entrance Type: SecondaryTraditional

Entrance Type: SecondaryMid-Century Modern / ContemporaryHornbake Library 147

Entrance Type: Service / Mech.TraditionalToll Physics 082

Entrance Type: TertiaryMid-Century Modern / ContemporaryVan Munching 039

Page 16: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

14 University of Maryland | Entrance Door Criteria

Case Example I: Edward St. John Learning and Teaching Center (Building 226)

Campus Core — Academic Use — Traditional

INT. STORM WINDOW AT TRANSOM

EXISTING TRANSOM SASH AND ARCHITECTURAL TRIM

REFURBISH EXISTING RAISED PANEL WOOD DOORS

INSUL. GLASS W/ SIM. DIVIDED LITES AND INTERNAL GRID DIVIDERS

WOOD DOOR W/ FIBERGLASS DOOR IN HM FRAME W/ WOOD TRIM

WOOD DOOR W/ RAISED PANEL (MODIFY EXISTING FRAME AND STOP FOR INSWINGING DOOR

INSUL. GLASS W/ SIM. DIVIDED LITES AND INTERNAL GRID DIVIDERS

EXISTING WOOD CASING AND TRIM RESTORED, INT STORM WINDOW AT TRANSOM

WOOD DOOR W/ RAISED PANEL (MODIFY EXISTING FRAME AND STOP FOR INSWINGING DOOR

INSUL. GLASS W/ SIM. DIVIDED LITES AND INTERNAL GRID DIVIDERS

EXISTING WOOD CASING AND TRIM RESTORED, INT STORM WINDOW AT TRANSOM

Page 17: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 15

Primary• Secure electronic locking• Hardware compatibility• Desire to include glass lites & historic character

Secondary• Wood replacement door specified for in-swinging

doors• Transom muntin patterns difficult to replicate

in door lites

Secondary to be ADA / Primary • Existing fire-rated stair egress• ADA accessibility required

Page 18: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

16 University of Maryland | Entrance Door Criteria

Case Example II: Plant Sciences (Building 036)

NE District — Academic Use — Contemporary

Primary• Delamination of white oak• Finish deterioration, difficult to refinish• Staining from closure oil• Replacement doors difficult to source

ADA Accessible Entry • Weather-stripping is problematic• Review auto-operator leaf designation on double

doors, breaks frequently• No available warranty

Page 19: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 17

TYPICAL DETAILS

FINISH FLOOR0' - 0"

FINISH FLOOR0' - 0"

MIN

1' - 0"1'

- 0"

EXTERIORINTERIOR

FINISH GRADE

TRANSOM (IF APPLICABLE)IN THE EVENT GLASS TRANSOM IS OBSCURED BY LOWERED CEILING @ INTERIOR - RETAIN EXTERIOR GLAZING AND PAINT INSIDE JAMBS & BACKGROUND TO CREATE SHADOW BOX EFFECT

DOOR JAMB AND FRAME (DOOR OMITTED FOR CLARITY)

SLOPE (AS PERMISSABLE BY ADA) FOR DRAINAGE AWAY FROM EXTERIOR BUILDING ENTRY

FINISH CEILING

REQUIRED CEILING MTD EXIT SIGN

MAINTAIN 1’-0” MIN CLEARANCE FROM TOP OF TRANSOM /DOOR OPENING TO FINISH CEILING

LOWERED CEILING AT ENTRY NOT PREFERRED

REQUIRED DOOR OPERATOR ARM HOUSING MOUNTED TO DOOR FRAME. PAINT REVERSE SIDE HOUSING/BLANK-OFF PLATE BLACK TO OBSCURE VISIBILITY FROM EXTERIOR

Typical Details:Typical Section @ Building Entry

The details on the following pages are intended as a guiding reference to designers, especially in instances requiring replacement of doors in the historic core of the University of Maryland College Park campus.Enlarged elevations with dimensions for raised panel door components are provided. Plan details for a corresponding wood raised panel door with glazed sidelights are also included.

ADA COMPLIANT THRESHOLD

INTERIOR EXTERIOR

TYPICAL SECTION AT BUILDING ENTRYDRAWING NOT TO SCALE

Page 20: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

18 University of Maryland | Entrance Door Criteria

Typical Details:Typical Raised Panel Door*FOR STOREFRONT DOORS REFER TO DCFS

6"

6" 6"5"

5"8

1/2"

10"

PLANDETAIL

POSSIBLE DECORATIVE MUNTINS/PATTERN AS APPROPRIATE PER EXISTING CONDITION OR PER DESIGN

TRANSOM PROPORTIONS TO ALIGN WITH DOOR EXTENTS WHERE APPLICABLE

PANELS AT SIDELITES TO ALIGN WITH DOOR PANELS

SIDELITE PANELS TO MATCH DOOR PANEL FABRICATION AND DIMENSIONS WHERE APPLICABLE

* DIMENSIONS SHOWN ARE DERIVED FROM WOOD DOOR MANUFACTURER RECOMMENDATIONS FOR INSTITUTIONAL APPLICATIONS

LOCK RAIL TO BE 6” MIN. TO RECEIVE EXIT DEVICE AS REQ’D

TOP RAIL TO BE 6” MIN. TO RECEIVE CLOSER

BOTTOM RAIL TO BE 10” MIN. PER ADA TO RECEIVE KICKPLATE AS REQ’D

TYPICAL RAISED PANEL DOOR ELEVATIONSDRAWINGS NOT TO SCALE UNLESS NOTED OTHERWISE

Page 21: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 19

TYPICAL DETAILS

CO

NST

RU

CTI

ON

VAR

IES

TYPI

CAL

SYS

TEM

DEP

TH V

ARIE

S

SEE ENLARGED DETAIL(THIS PAGE)

CO

NST

RU

CTI

ON

VAR

IES

TYPI

CAL

SYS

TEM

DEP

TH V

ARIE

S

EXTERIOR

INTERIOR

PLAN - TYPICAL PANEL DOOR & SIDELITES

MUNTIN DETAIL @ GLAZED DOOR LITES ALTERNATIVE DOOR JAMB @ SIDELITES

DOOR PLAN DETAIL

APPLIED WOOD MUNTIN

INTEGRAL SPACER

DOUBLE LAYER GLAZING

GLAZED SIDELITE

RECESSED RACEWAY FOR ELEC.

TYPICAL SIDELITE CONSTRUCTION RECESSED

RACEWAY FOR ELEC.

WOOD TRIM

Page 22: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

20 University of Maryland | Entrance Door Criteria

Typical Details:Typical Door Hardware

* GENERIC DOORS SHOWN - APPLICABLE FOR BUILDING ENTRANCE TYPES GOVERNED BY DCFS* REFER TO COLOR PALETTE LEGEND FOR HARWARE FINISH MATERIAL* REFER TO DCFS HARDWARE SECTION FOR ADDITIONAL HARDWARE STANDARDS i.eTHRESHOLDWEATHERSTRIPPINGLOCKSETSHINGESDEVICE TRIMSSECURITY ELEMENTS

DOUBLE DOOR ELEVATION INCLUDING HARDWARE

EXTERIOR

INTERIOR

DOOR PULL AND PLATE - ACTIVE LEAF ONLY

DOOR PLATE AT INACTIVE LEAF

CONTINUOUS HINGES, TYP

METAL KICKPLATE AT BOTTOM RAIL

EXIT SIGNAGE LOCATED PER APPLICABLE CODE

CLOSER (INCLUDE AUTO-OPERATOR WHERE REQ’D FOR ACCESSIBILITY)

EXIT DEVICE

REMOVABLE MULLION IF REQ’D

Page 23: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 21

TYPICAL DETAILS

DOOR PULL - SEE DCFS HARDWARE STANDARDS

CONTINUOUS HINGES

METAL KICKPLATE AT BOTTOM RAIL

EXIT SIGNAGE LOCATED PER APPLICABLE CODE

CLOSER (INCLUDE AUTO-OPERATOR WHERE REQ’D FOR ACCESSIBILITY)

CONTINUOUS HINGES

EXIT DEVICE

METAL KICKPLATE AT BOTTOM RAIL

SINGLE DOOR ELEVATION INCLUDING HARDWARE

EXTERIOR

INTERIOR

* GENERIC DOORS SHOWN - APPLICABLE FOR BUILDING ENTRANCE TYPES GOVERNED BY DCFS* REFER TO COLOR PALETTE LEGEND FOR HARWARE FINISH MATERIAL* REFER TO DCFS HARDWARE SECTION FOR ADDITIONAL HARDWARE STANDARDS i.eTHRESHOLDWEATHERSTRIPPINGLOCKSETSHINGESDEVICE TRIMSSECURITY ELEMENTS

Page 24: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

22 University of Maryland | Entrance Door Criteria

Typical Details: Building Color Palette

ERA

TRAD

ITIO

NAL

MID

-CEN

TUR

YM

ID-C

ENTU

RY

MO

DER

N

DOOR AND SIDELITES

PRIMARY

FRAME

DOOR PULLS / EXIT DEVICE

DOOR AND SIDELITES

FRAME

DOOR PULLS / EXIT DEVICE

DOOR AND SIDELITES

FRAME

DOOR PULLS / EXIT DEVICE

LEGEND

PAINT -SHERWIN WILLIAMS SW7005 PURE WHITE / EQUIVALENT OR MATCH OWNER’S SAMPLE

METAL/FRP - SHERWIN WILLIAMS SW7005 PURE WHITE / EQUIVALENT OR MATCH OWNER’S SAMPLE

METAL FINISH - KAWNEER #14 CLEAR OR MATCH OWNER’S SAMPLE

PAINT - GREY TO MATCH OWNER’S SAMPLE

METAL FINISH - KAWNEER #28 MEDIUM BRONZE OR EQUIVALENT

HARDWARE - ALLEGION - DARK BRONZE 613 OR MATCH OWNER’S SAMPLE

HARDWARE - IVES - SATIN STAIN-LESS STEEL 630 OR MATCH OWN-ER’S SAMPLE

/CO

NTE

MPO

RAR

Y

Page 25: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 23

TYPICAL DETAILS

SECONDARY TERTIARY

DOOR AND SIDELITES

FRAME

DOOR PULLS / EXIT DEVICE

DOOR AND SIDELITES

FRAME

DOOR PULLS / EXIT DEVICE

DOOR AND SIDELITES

FRAME

DOOR PULLS / EXIT DEVICE

FRAME

DOOR PULLS / EXIT DEVICE

DOOR AND SIDELITES

DOOR AND SIDELITES

FRAME

DOOR PULLS / EXIT DEVICE

DOOR AND SIDELITES

FRAME

DOOR PULLS / EXIT DEVICE

Page 26: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

24 University of Maryland | Entrance Door Criteria

Page 27: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 25

Academic / Administrative BuildingsDoor Recommendation

PRIMARY ENTRY

SECONDARY ENTRY

TERTIARY ENTRY

TRADITIONAL BUILDING

A1-T ADA

A1-TB

A3-TBA3-TA

A2-T

A1-T -TA

NOTE: Any ADA-accessible entrance, regardless of location (i.e. front, rear, side, etc.) will be considered a “Primary Entrance” for mobility-challenged and all other persons with disabilities. All “Primary Entrances” will be reviewed by the ALRB prior to work / repair / replacement.

Page 28: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

26 University of Maryland | Entrance Door Criteria

Academic Traditional Primary ADA EntryExisting Conditions

@ WOODS HALL 047

TYPICAL ADA WOOD RAISED PANEL DOOR TO BE REPLACED

Page 29: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 27

Replacement / New Door Options

A1-T-ADA

Manufacturers:HARRING

LEMIEUX

SIMPSON

JELD-WEN

EXTERIOR INTERIOR

ALIGN

RETAIN EXISTING TRANSOM SASH AND ARCHITECTURAL TRIM

EXIT DEVICE

*CONSIDERATION TO BE GIVEN TO PROPORTIONS OF TRANSOM AND ADJACENT WINDOW LITES WHEN SIZING GLASS LITES AT DOOR AND SIDELITES.

ACADEMIC / ADMINISTRATIVE BUILDINGS

INSULATED GLASS W/ SURFACE-APPLIED MUNTINS AND INTERNAL GRID DIVIDERS - SEE TYPICAL DETAILS @ RAISED PANEL DOOR

RAISED PANEL DOOR AND SIDELITE PANELS

Material: Aluminum

Finish:

See Color Palette

*DRAWINGS NOT TO SCALE

AUTO CLOSER

Page 30: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

28 University of Maryland | Entrance Door Criteria

Academic Traditional Primary EntryNON-ADA - OPTION AExisting Conditions

@ WOODS HALL 047

TYPICAL WOOD RAISED PANEL DOUBLE DOOR TO BE REPLACED

Page 31: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 29

Replacement / New Door Options

A1-T-TA

Manufacturers:HARRING

LEMIEUX

SIMPSON

JELD-WEN

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Wood

Finish:

See Color Palette

EXTERIOR INTERIOR

INTERIOR STORM WINDOW AT TRANSOM

EXIT DEVICE

RETAIN EXISTING TRANSOM SASH & ARCHITECTURAL TRIM

REPLACE OR REFURBISH WOOD PANEL DOOR TO MATCH EXISTING IN-KIND

*DRAWINGS NOT TO SCALE

Page 32: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

30 University of Maryland | Entrance Door Criteria

Academic Traditional Primary EntryNON-ADA - OPTION BExisting Conditions

TYPICAL HALF GLASS & WOOD RAISED PANEL DOUBLE DOOR TO BE REPLACED

@ ARCHITECT’S RENDITION

Page 33: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 31

Replacement / New Door Options

A1-T-TB

Manufacturers:HARRING

LEMIEUX

SIMPSON

JELD-WEN

EXTERIOR INTERIOR

“CONSIDERATION TO BE GIVEN TO PROPORTIONS OF TRANSOM AND ADJACENT WINDOW LITES WHEN SIZING GLASS LITES AT DOOR AND SIDELITES.

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Wood

Finish:

See Color Palette

INTERIOR STORM WINDOW AT TRANSOM

EXIT DEVICE

RETAIN EXISTING TRANSOM SASH & ARCHITECTURAL TRIM

INSULATED GLASS W/ SURFACE-APPLIED MUNTINS AND INTERNAL GRID DIVIDERS

SOLID WOOD DOOR W/ RAISED PANELS

*DRAWINGS NOT TO SCALE

Page 34: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

32 University of Maryland | Entrance Door Criteria

Academic Traditional Secondary EntryExisting Conditions

@ COLE 162

TYPICAL SINGLE WOOD RAISED PANEL DOOR TO BE REPLACED

Page 35: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 33

Replacement / New Door Options

A2-T

Manufacturers:HARRING

LEMIEUX

SIMPSON

JELD-WEN

EXTERIOR INTERIOR

“CONSIDERATION TO BE GIVEN TO PROPORTIONS OF TRANSOM (IF PRESENT) AND ADJACENT WINDOW LITES WHEN SIZING GLASS LITES AT DOOR AND SIDELITES.

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Aluminum

Finish:

See Color Palette

DIVIDED GLASS LITES

ALUMINUM DOOR WITH RAISED PANELS

HOLLOW METAL FRAME

EXIT DEVICE

*DRAWINGS NOT TO SCALE

Page 36: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

34 University of Maryland | Entrance Door Criteria

Academic Traditional Tertiary Single EntryExisting Conditions

TYPICAL HOLLOW METAL SINGLE DOOR TO BE REPLACED

@ SYMONS HALL 076

Page 37: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 35

Replacement / New Door Options

A3-TA

EXTERIOR INTERIOR

ACADEMIC / ADMINISTRATIVE BUILDINGS

Manufacturers:SPECIAL-LITE

CURRIES

CECO DOORS

Material: Hollow Metal

Finish:

See Color Palette

2” HOLLOW METAL FRAME

LOUVER IF REQUIRED

HOLLOW METAL DOOR, PAINTED

*DRAWINGS NOT TO SCALE

EXIT DEVICE

Page 38: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

36 University of Maryland | Entrance Door Criteria

Academic Traditional Service Entry

Existing Conditions

@ PLANT SCIENCES 036

TYPICAL HOLLOW METAL DOUBLE DOOR WITH GLASS LITES TO BE REPLACED

Page 39: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 37

Replacement / New Door Options

A3-TB

Manufacturers:SPECIAL-LITE

CURRIES

CECO DOORS

EXTERIOR INTERIOR

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Hollow Metal

Finish:

See Color Palette

2” HOLLOW METAL FRAME

VISION PANELS @ SERVICE ENTRY ONLY

HOLLOW METAL DOOR, PAINTED

*DRAWINGS NOT TO SCALE

EXIT DEVICE IF REQUIRED

Page 40: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

38 University of Maryland | Entrance Door Criteria

Page 41: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 39

Academic / Administrative BuildingsDoor Recommendation

PRIMARY ENTRY

SECONDARY ENTRY

TERTIARY ENTRY

TRADITIONAL BUILDING

MID-CENTURY BUILDING

A1-M

*A3-M

A2-M

A1-T ADA

A1-TB

A3-TBA3-TA

A2-T

A1-T -TA

NOTE: DOORS THAT ARE CONSIDERED EXEMPT ARE THOSE NOT REQUIRED TO COMPLY WITH CURRENT ACCESSIBILITY CODES, MOST OFTEN DUE TO THE HISTORIC NATURE OF THE ENTRANCE OR BUILDING. THOSE DOORS MARKED NON-EXEMPT MAY HAVE HISTORIC CRITERIA BUT ARE REQUIRED TO COMPLY WITH ACCESSIBILITY CODES.

* SPECIFIC EXAMPLE SHOWN IS SIMILAR AND APPLICABLE TO MID-CENTURY MODERN BUILDINGS

Page 42: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

40 University of Maryland | Entrance Door Criteria

Academic Mid-Century Primary Entry

Existing Conditions

@ PARREN J. MITCHELL - ART SOCIOLOGY 146

TYPICAL BRONZE ALUMINUM STOREFRONT DOUBLE DOOR TO BE REPLACED

Page 43: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 41

Replacement / New Door Options

A1-M

Manufacturers:SPECIAL-LITE

CECO DOORS

KAWNEER

YKK

EFCO

EXTERIOR INTERIOR

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Aluminum

Finish:

See Color Palette

2” ALUMINUM FRAME

HORIZONTAL MULLION

GLAZING PANELS

EXIT DEVICE

*DRAWINGS NOT TO SCALE

ALIGN

AUTO CLOSER

Page 44: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

42 University of Maryland | Entrance Door Criteria

Academic Mid-Century Secondary EntryExisting Conditions

@ HORNBAKE LIBRARY 147

TYPICAL METAL & GLASS DOOR TO BE REPLACED

Page 45: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 43

Replacement / New Door Options

A2-M

Manufacturers:SPECIAL-LITE

CECO DOORS

KAWNEER

YKK

EFCO

EXTERIOR INTERIOR

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Aluminum

Finish:

See Color Palette

TRANSOM

ALUMINUM FRAME

HORIZONTAL MULLION

GLAZING PANEL

EXIT DEVICE

*DRAWINGS NOT TO SCALE

ALIGN

Page 46: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

44 University of Maryland | Entrance Door Criteria

Academic Mid-Century Tertiary Entry

Existing Conditions

@ VAN MUNCHING 039

TYPICAL HOLLOW METAL MECHANICAL ROOM DOUBLE DOOR WITH HOLLOW METAL FRAME TO BE REPLACED

Page 47: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 45

Replacement / New Door Options

A3-M

Manufacturers:SPECIAL-LITE

CURRIES

CECO DOORS

EXTERIOR INTERIOR

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Hollow Metal

Finish:

See Color Palette

2” HOLLOW METAL FRAME

HOLLOW METAL DOOR, PAINTED

EXIT DEVICE IF REQUIRED

*DRAWINGS NOT TO SCALE

Page 48: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

46 University of Maryland | Entrance Door Criteria

Page 49: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 47

Academic / Administrative BuildingsDoor Recommendation

PRIMARY ENTRY

SECONDARY ENTRY

TERTIARY ENTRY

TRADITIONAL BUILDING

MID-CENTURY BUILDING

A1-M

*A3-M

A2-M

CONTEMPORARY BUILDING

*A1-C

*A3-C

A2-C ADA

* SPECIFIC EXAMPLE SHOWN IS SIMILAR AND APPLICABLE TO MID-CENTURY MODERN BUILDINGS

A1-T ADA

A1-TB

A3-TBA3-TA

A2-T

A1-T -TA

NOTE: DOORS THAT ARE CONSIDERED EXEMPT ARE THOSE NOT REQUIRED TO COMPLY WITH CURRENT ACCESSIBILITY CODES, MOST OFTEN DUE TO THE HISTORIC NATURE OF THE ENTRANCE OR BUILDING. THOSE DOORS MARKED NON-EXEMPT MAY HAVE HISTORIC CRITERIA BUT ARE REQUIRED TO COMPLY WITH ACCESSIBILITY CODES.

Page 50: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

48 University of Maryland | Entrance Door Criteria

Academic Contemporary Primary EntryExisting Conditions

@ ANIMAL SCIENCES 142

TYPICAL ALUMINUM STOREFRONT DOUBLE DOOR TO BE REPLACED

Page 51: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 49

Replacement / New Door Options

A1-C

Manufacturers:SPECIAL-LITE

CECO DOORS

KAWNEER

YKK

EFCO

EXTERIOR INTERIOR

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Aluminum

Finish:

See Color Palette

2” ALUMINUM FRAME

HORIZONTAL MULLION

GLAZING PANELS

EXIT DEVICE

*DRAWINGS NOT TO SCALE

ALIGN

Page 52: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

50 University of Maryland | Entrance Door Criteria

Academic Contemporary ADA Entry

Existing Conditions

@ HORNBAKE LIBRARY 147

TYPICAL METAL DOOR AND SIDELITE TO BE REPLACED

Page 53: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 51

Replacement / New Door Options

A2-C-ADA

Manufacturers:SPECIAL-LITE

CURRIES

CECO DOORS

EXTERIOR INTERIOR

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Hollow Metal

Finish:

See Color Palette

TRANSOM

SIDELIGHT GLAZING PANELS

HORIZONTAL MULLION

GLAZING PANEL

ALUMINUM FRAME

EXIT DEVICE

*DRAWINGS NOT TO SCALE

ALIGN

Page 54: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

52 University of Maryland | Entrance Door Criteria

Academic Contemporary Tertiary EntryExisting Conditions

@ VAN MUNCHING 039

TYPICAL HOLLOW METAL MECHANICAL ROOM DOUBLE DOOR WITH HOLLOW METAL FRAME TO BE REPLACED

Page 55: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 53

Replacement / New Door Options

A3-C

Manufacturers:SPECIAL-LITE

CURRIES

CECO DOORS

EXTERIOR INTERIOR

ACADEMIC / ADMINISTRATIVE BUILDINGS

Material: Hollow Metal

Finish:

See Color Palette

2” HOLLOW METAL FRAME

HOLLOW METAL DOOR, PAINTED

EXIT DEVICE IF REQUIRED

*DRAWINGS NOT TO SCALE

Page 56: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

54 University of Maryland | Entrance Door Criteria

Page 57: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 55

Assembly / Events BuildingsDoor Recommendation

PRIMARY ENTRY

SECONDARY ENTRY

TERTIARY ENTRY

TRADITIONAL BUILDING

E1-T ADA

E1-T

E3-T

E2-T

NOTE: DOORS THAT ARE CONSIDERED EXEMPT ARE THOSE NOT REQUIRED TO COMPLY WITH CURRENT ACCESSIBILITY CODES, MOST OFTEN DUE TO THE HISTORIC NATURE OF THE ENTRANCE OR BUILDING. THOSE DOORS MARKED NON-EXEMPT MAY HAVE HISTORIC CRITERIA BUT ARE REQUIRED TO COMPLY WITH ACCESSIBILITY CODES.

Page 58: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

56 University of Maryland | Entrance Door Criteria

Assembly & Events Traditional Primary EntryExisting Conditions

@ RITCHIE COLOSSEUM 004

TYPICAL RAISED PANEL DOOR TO BE REPLACED

Page 59: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 57

Replacement / New Door Options

E1-T

ASSEMBLY / EVENTS BUILDINGS

Manufacturers:HARRING

LEMIEUX

SIMPSON

JELD-WEN

Material: Wood / Aluminum

Finish:

See Color Palette

EXTERIOR INTERIOR

ALUMINUM DOOR WITH RAISED PANELS

EXIT DEVICE

* EXCEPTION: REPLACEMENT WOOD DOORS ALLOWED WHERE WEATHER PROTECTION IS PROVIDED

*DRAWINGS NOT TO SCALE

Page 60: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

58 University of Maryland | Entrance Door Criteria

Assembly & Events Traditional Primary ADA EntryExisting Conditions

@ MEMORIAL CHAPEL - EAST DOOR 009

TYPICAL NON-ACCESSIBLE WOOD DOUBLE DOOR TO BE REPLACED

Page 61: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 59

Replacement / New Door Options

E1-T-ADA

* SINGLE WOOD DOOR SIMULATED DESIGN TO APPEAR AS DOUBLE DOORS

ASSEMBLY / EVENTS BUILDINGS

Manufacturers:HARRING

LEMIEUX

SIMPSON

JELD-WEN

Material: Wood

Finish:

See Color Palette

EXTERIOR INTERIOR

EXIT DEVICE

FIXED WOOD RAISED PANELS, PAINTED

RAISED PANELS - CUSTOM DESIGN TO MATCH EXISTING DOOR

*DRAWINGS NOT TO SCALE

SCORED LINE TO REPLICATE DOOR EDGE

Page 62: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

60 University of Maryland | Entrance Door Criteria

Assembly & Events Traditional Secondary EntryExisting Conditions

@ RECKORD ARMORY 078

TYPICAL WOOD RAISED PANEL DOUBLE DOOR TO BE REPLACED

Page 63: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 61

Replacement / New Door Options

E2-T

ASSEMBLY / EVENTS BUILDINGS

Manufacturers:HARRING

LEMIEUX

CUSTOM

Material: Wood

Finish:

See Color Palette

EXIT DEVICE

EXISTING TRANSOM SASH AND ARCHITECTURAL TRIM

REPLACE WOOD PANEL DOOR TO MATCH EXISTING IN-KIND

EXTERIOR INTERIOR

*DRAWINGS NOT TO SCALE

ALIGN HINGE-SIDE OF DOOR WITH TRANSOM EDGE

Page 64: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

62 University of Maryland | Entrance Door Criteria

Assembly & Events Traditional Tertiary EntryExisting Conditions

TYPICAL HOLLOW METAL DOUBLE DOOR WITH HOLLOW METAL FRAME TO BE REPLACED

@ COLE FIELD HOUSE 162

Page 65: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 63

Replacement / New Door Options

E3-T

ASSEMBLY / EVENTS BUILDINGS

Manufacturers:SPECIAL-LITE

CURRIES

CECO DOORS

Material: Hollow Metal

Finish:

See Color Palette

2” HOLLOW METAL FRAME

EXTERIOR INTERIOR

VISION PANELS - 6”W x 24-30”H @ SERVICE ENTRY ONLY

HOLLOW METAL DOOR, PAINTED

*DRAWINGS NOT TO SCALE

EXIT DEVICE IF REQUIRED

Page 66: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

64 University of Maryland | Entrance Door Criteria

Page 67: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 65

Assembly / Events BuildingsDoor Recommendation

PRIMARY ENTRY

SECONDARY ENTRY

TERTIARY ENTRY

TRADITIONAL BUILDING

E1-T ADA

E1-T

E3-T

E2-T

MID-CENTURYBUILDING

E1-M

E3-M

E2-M

NOTE: DOORS THAT ARE CONSIDERED EXEMPT ARE THOSE NOT REQUIRED TO COMPLY WITH CURRENT ACCESSIBILITY CODES, MOST OFTEN DUE TO THE HISTORIC NATURE OF THE ENTRANCE OR BUILDING. THOSE DOORS MARKED NON-EXEMPT MAY HAVE HISTORIC CRITERIA BUT ARE REQUIRED TO COMPLY WITH ACCESSIBILITY CODES.

Page 68: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

66 University of Maryland | Entrance Door Criteria

Assembly & Events Mid-Century Primary EntryExisting Conditions

@ SOUTH CAMPUS DINING 026

TYPICAL ALUMINUM STOREFRONT DOUBLE DOOR TO BE REPLACED

Page 69: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 67

Replacement / New Door Options

E1-M

Manufacturers:SPECIAL-LITE

CECO DOORS

KAWNEER

YKK

EFCO

EXTERIOR INTERIOR

Material: Aluminum

Finish:

See Color Palette

2” ALUMINUM FRAME

HORIZONTAL MULLION

GLAZING PANELS

ALIGN

EXIT DEVICE

ASSEMBLY / EVENTS BUILDINGS

*DRAWINGS NOT TO SCALE

Page 70: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

68 University of Maryland | Entrance Door Criteria

Assembly & Events Mid-Century Secondary EntryExisting Conditions

@ SOUTH CAMPUS DINING 026

TYPICAL NARROW LEAF ALUMINUM AND GLASS STOREFRONT DOUBLE DOOR TO BE REPLACED

Page 71: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 69

Replacement / New Door Options

E2-M

Manufacturers:SPECIAL-LITE

CECO DOORS

KAWNEER

YKK

EFCO

EXTERIOR INTERIOR

Material: Aluminum

Finish:

See Color Palette

ALUMINUM FRAME

HORIZONTAL MULLION

GLAZING PANELS

EXIT DEVICE

ASSEMBLY / EVENTS BUILDINGS

*DRAWINGS NOT TO SCALE

Page 72: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

70 University of Maryland | Entrance Door Criteria

Assembly & Events Mid-Century Tertiary EntryExisting Conditions

@ SOUTH CAMPUS DINING 026

TYPICAL HOLLOW METAL MECHANICAL ROOM DOUBLE DOOR WITH HOLLOW METAL FRAME TO BE REPLACED

Page 73: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 71

Replacement / New Door Options

E3-M

Manufacturers:SPECIAL-LITE

CURRIES

CECO DOORS

EXTERIOR INTERIOR

Material: Hollow Metal

Finish:

See Color Palette

2” HOLLOW METAL FRAME

HOLLOW METAL DOOR, PAINTED

EXIT DEVICE IF REQUIRED

ASSEMBLY / EVENTS BUILDINGS

*DRAWINGS NOT TO SCALE

Page 74: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

72 University of Maryland | Entrance Door Criteria

Page 75: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 73

Residential Facility BuildingsDoor Recommendation

PRIMARY ENTRY

SECONDARY ENTRY

TERTIARY ENTRY

TRADITIONAL BUILDING

R1-T ADA

R1-T

R3-T

R2-T

R1-T

GREEK

R2-T

GREEK

R3-T

GREEK

NOTE: DOORS THAT ARE CONSIDERED EXEMPT ARE THOSE NOT REQUIRED TO COMPLY WITH CURRENT ACCESSIBILITY CODES, MOST OFTEN DUE TO THE HISTORIC NATURE OF THE ENTRANCE OR BUILDING. THOSE DOORS MARKED NON-EXEMPT MAY HAVE HISTORIC CRITERIA BUT ARE REQUIRED TO COMPLY WITH ACCESSIBILITY CODES.

Page 76: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

74 University of Maryland | Entrance Door Criteria

Residential Traditional Primary Entry

@ HARFORD HALL 014

TYPICAL RAISED PANEL DOOR + SIDE PANELS TO BE REPLACED

* EXAMPLE OF PRIMARY ENTRANCE DOOR FOR TRADITIONAL BUILDINGS WITH SUITES AND APARTMENTS (ENTRANCE IS TO STAIRWELL)

Page 77: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 75

Replacement / New Door Options

R1-T

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

ALIGN PANEL AND RAIL DIMENSIONS @ SIDE W/ DOOR RAILS AND PANELS PER GUIDELINES

SOLID FRP DOOR W/ APPLIED MOULDING

HOLLOW METAL FRAME

EXIT DEVICE

*DRAWINGS NOT TO SCALE

AUTOMATIC DOOR OPERATOR IF APPLICABLE

Page 78: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

76 University of Maryland | Entrance Door Criteria

Residential Traditional ADA Entry

Existing Conditions

@ ANNE ARUNDEL HALL 060

TYPICAL FRP DOOR W/ APPLIED TRIM TO BE REPLACED

* EXAMPLE OF PRIMARY ENTRANCE DOOR FOR TRADITIONAL DOUBLE LOADED CORRIDOR BUILDINGS (ENTRANCE IS TO LOBBY)

Page 79: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 77

Replacement / New Door Options

R1-T-ADA

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

RETAIN GLASS TRANSOM IN-KIND WHERE POSSIBLE

SOLID FRP DOOR W/ APPLIED MOULDING

HOLLOW METAL FRAME

EXIT DEVICE

ALIGN PANEL AND RAIL DIMENSIONS @ SIDE W/ DOOR RAILS AND PANELS PER GUIDELINES

AUTO OPERATOR (IF ADA ACCESS IS APPLICABLE)

*DRAWINGS NOT TO SCALE

Page 80: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

78 University of Maryland | Entrance Door Criteria

Residential Traditional Primary Greek House EntryExisting Conditions

@ FRATERNITY ROW 003

Page 81: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 79

Replacement / New Door Options

R1-T-GREEK

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

FROSTED GLASS @ SIDELITES, TYP

SOLID FRP DOOR W/ APPLIED MOULDING

HOLLOW METAL FRAME

EXIT DEVICE

ALIGN PANEL AND RAIL DIMENSIONS @ SIDE W/ DOOR RAILS AND PANELS PER GUIDELINES

AUTO OPERATOR (IF ADA ACCESS IS APPLICABLE)

*DRAWINGS NOT TO SCALE

Page 82: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

80 University of Maryland | Entrance Door Criteria

Residential Traditional Secondary EntryExisting Conditions

@ HARFORD HALL 014

TYPICAL RAISED PANEL DOOR TO BE REPLACED

Page 83: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 81

Replacement / New Door Options

R2-T

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

FRAME MATERIAL TO MATCH DOOR IF FRAME IS REPLACED

SOLID FRP DOOR W/ APPLIED MOULDING

EXIT DEVICE

*DRAWINGS NOT TO SCALE

AUTO OPERATOR (IF ADA ACCESS IS APPLICABLE)

Page 84: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

82 University of Maryland | Entrance Door Criteria

Residential Traditional Secondary Greek House EntryExisting Conditions

@ FRATERNITY ROW 003

TYPICAL FRP DOOR W/ RAISED PANEL TO BE REPLACED

Page 85: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 83

Replacement / New Door Options

R2-T-GREEK

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

*DRAWINGS NOT TO SCALE

FRAME MATERIAL TO MATCH DOOR IF FRAME IS REPLACED

SOLID FRP DOOR W/ APPLIED MOULDING

EXIT DEVICE

Page 86: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

84 University of Maryland | Entrance Door Criteria

Residential Traditional Tertiary Entry

Existing Conditions

@ ANNE ARUNDEL HALL 060

Page 87: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 85

Replacement / New Door Options

R3-T

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

INFILLED TRANSOM WHERE APPLICABLE

SOLID FRP DOOR W/ APPLIED MOULDING

EXIT DEVICE

RAISED PANELS AT TRANSOM TO BE SIMILAR PROPORTION TO DOOR PANELS

HOLLOW METAL FRAME

INTERIOR FACE OF DOOR TO BE FLUSH

*DRAWINGS NOT TO SCALE

Page 88: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

86 University of Maryland | Entrance Door Criteria

Residential Traditional Tertiary Greek House EntryExisting Conditions

@ FRATERNITY ROW 012

TYPICAL FLUSH HOLLOW METAL DOOR TO BE REPLACED

Page 89: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 87

Replacement / New Door Options

R3-T-GREEK

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: Flush Hollow Metal Or FRP If Below Grade

Finish:

Smooth / Matte

LOUVER IF REQUIRED

EXIT DEVICE

FRAME MATERIAL TO MATCH DOOR IF FRAME IS REPLACED

*DRAWINGS NOT TO SCALE

Page 90: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

88 University of Maryland | Entrance Door Criteria

Page 91: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 89

Residential Facility BuildingsDoor Recommendation

PRIMARY ENTRY

SECONDARY ENTRY

TERTIARY ENTRY

MID-CENTURYBUILDING

R3-M

R2-M

TRADITIONAL BUILDING

R1-T ADA

R1-T

R3-T

R2-T

R1-T

GREEK

R2-T

GREEK

R3-T

GREEK

R1-M ADA

R2a-M

NOTE: DOORS THAT ARE CONSIDERED EXEMPT ARE THOSE NOT REQUIRED TO COMPLY WITH CURRENT ACCESSIBILITY CODES, MOST OFTEN DUE TO THE HISTORIC NATURE OF THE ENTRANCE OR BUILDING. THOSE DOORS MARKED NON-EXEMPT MAY HAVE HISTORIC CRITERIA BUT ARE REQUIRED TO COMPLY WITH ACCESSIBILITY CODES.

Page 92: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

90 University of Maryland | Entrance Door Criteria

Residential Mid-Century Primary ADA EntryExisting Conditions

@ DENTON HALL 252

Page 93: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 91

Replacement / New Door Options

R1-M-ADA

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

GLAZED PANELS

EXIT DEVICE

EXISTING GLAZED TRANSOM TO REMAIN, TYP

AUTO OPERATOR

HOLLOW METAL FRAME

HEAD RAIL AND STILE DIMENSIONS TO BE EQUAL AND NOT GREATER THAN 7” AT SIMILAR DOORS WITH GLAZED LITES

*DRAWINGS NOT TO SCALE

Page 94: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

92 University of Maryland | Entrance Door Criteria

Residential Mid-Century Secondary EntryExisting Conditions

@ CUMBERLAND HALL 122

TYPICAL FRP DOOR W/ APPLIED TRIM TO BE REPLACED

* EXAMPLE OF SECONDARY ENTRANCE (EXIT ONLY) DOOR FOR MID-CENTURY HIGHRISE RESIDENCE HALL

Page 95: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 93

Replacement / New Door Options

R2-M

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

SOLID FRP DOOR WITH APPLIED MOULDING

EXIT DEVICE

RETAIN EXISTING TRANSOM SASH AND ARCHITECTURAL TRIM IF APPLICABLE

INTERIOR STORM WINDOW AT TRANSOM

HOLLOW METAL FRAME

*DRAWINGS NOT TO SCALE

Page 96: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

94 University of Maryland | Entrance Door Criteria

Residential Mid-Century Secondary Entry 2Existing Conditions

@ CAMBRIDGE HALL 096

TYPICAL FRP RAISED PANEL DOOR TO BE REPLACED

* EXAMPLE OF 5’ WIDE SECONDARY ENTRANCE DOOR FOR MID-CENTURY HIGHRISE RESIDENCE HALL

Page 97: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 95

Replacement / New Door Options

R2a-M

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

SOLID FRP DOOR WITH RAISED PANELS

EXIT DEVICE

ALIGN PANEL AND RAIL DIMENSIONS @ SIDE W/ DOOR RAILS AND PANELS PER GUIDELINES

HOLLOW METAL FRAME

*DRAWINGS NOT TO SCALE

Page 98: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

96 University of Maryland | Entrance Door Criteria

Residential Mid-Century Tertiary EntryExisting Conditions

@ CENTERVILLE HALL 098

TYPICAL FRP DOOR WITH APPLIED TRIM TO BE REPLACED

* EXAMPLE OF TERTIARY ENTRANCE DOOR FOR MID-CENTURY HIGHRISE RESIDENCE HALL

Page 99: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 97

Replacement / New Door Options

R3-M

EXTERIOR INTERIOR

RESIDENTIAL BUILDINGS

Material: FRP

Finish:

Smooth / Matte

EXIT DEVICE

HEAD RAIL AND STILE DIMENSIONS TO BE EQUAL AND NOT GREATER THAN 7” AT SIMILAR DOORS WITH GLAZED LITES

HOLLOW METAL FRAME

*DRAWINGS NOT TO SCALE

SOLID FRP DOOR WITH APPLIED MOULDING

Page 100: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

98 University of Maryland | Entrance Door Criteria

Procedure For Exterior Doors

REPLACEMENT (IF EXCEPTION IS REQUIRED PER DCFS)

DEPARTMENT HEAD REQUEST

TECHNICAL REVIEWDepartment of Public SafetyDepartment of Residential Facilities Department of Facilities Management: - Facility Planning - Design & Construction - Operations & Maintenance

CONSTRUCTIONSubmittal Review to Confirm Compliance with Guidelines

PROJECT MANAGER CONSULTS DCFS

APPROVAL BY ALRB CHAIR

REJECTED NEEDS ALRB REVIEW APPROVED

Page 101: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

University of Maryland | Entrance Door Criteria 99

DESIGN (AT NEW BUILDINGS)

ARCHITECT CONSULTS DCFS

TECHNICAL REVIEWDepartment of Public SafetyDepartment of Residential Facilities Department of Facilities Management: - Facility Planning - Design & Construction - Operations & Maintenance

CONSTRUCTIONSubmittal Review to Confirm Compliance with Guidelines

REVIEW WITH UMD CAPITAL PROJECTS

ALRB REVIEWSD & DD Phases

Page 102: University of Maryland College Park Campus …...University of Maryland | Entrance Door Criteria 3“The preparation of Design Criteria for the variety of Entrance Doors, both replacement

100 University of Maryland | Entrance Door Criteria