V200415 SOYAL ACCESS CONTROL SYSTEM ® LED1 LED2/3 DO1 ~ DO4 DI1 ~ DI4 DI4 DI4 DO4 DO1 DO2 DO3 DO4 DI3 DI3 DO3 DI2 DI2 DO2 DI1 DI1 L+ V+ V- L- DO1 RS485 TxRx POWER RS485 DI1~4 DO1~4 AR-403-IO-0001M-IR (AR-403-IO-0001M-IR) (AR-403-IO-0404M) (AR-403-IO-0202M) (AR-403-IO-0404M) (AR-403-IO-0202M-IR) 1 1 5 9 2 2 6 10 3 3 7 11 4 4 8 12 AR-403-IO-0001M-IR AR-403-IO Series 3 ~ 6 cm 7 ~ 9 cm 10 ~ 15 cm A Y B ( Y0 ) Universal I/O module(Option: Infrared sensor module) (Up to 24VDC/2000mA High Power MOSFET output) AR-403-IO Series Product PIN Define Infrared Module / I/O Module 1 Product Indicator Cable Instruction Application of mailbox---Wiring Diagram Wiring & Application Indicator Color Description LED1 Green POWER LED2 Green RS485 TxRx Communication indicator LED3 Red DO1 Red DO1Action indicator(Mailbox mode: letter indicator, blue LED) DO2 DO2Action indicator DO3 DO3Action indicator DO4 DO4Action indicator DI 1 Green DI1Action indicator DI 2 DI2Action indicator DI 3 DI3Action indicator DI 4 DI4Action indicator Sensor for delivering letters Indicator for letters inside Door Sensor Cabinet Lock AR-403-IO-0404M / AR-403-IO-0202M-IRCable Instruction: AR-403-IO-0001M-IRCable Instruction: Function Cable AR-403-IO-0404M (Standard mode) Description AR-403-IO-0202M-IR (Mailbox mode) V- Input 1 Power GND VIN Input 2 Positive power supply, range of volt: 9~24V RS-485 LA 3 RS-485 L+ contact RS-485 LB 4 RS-485 L- contact DI1 5 Input point, triggered by the low electric potential Delivering Letters DetectionWhen DI1 detect the letters are dropped, DO1 will be active to light on indicator. DI2 6 Door Status Detection: When DI2 door sensor detects that the door is closed, the indicator will light off DI3 7 DI4 8 DO1 9 MOSFET output, driven by 24VDC / 2A Letters Indicator Output: When DI1 detects the letters are dropped and it will output 1Hz ON/OFF flashing signal; Stop the output till DI2 detects OFF-ON-OFF motion of the door. DO2 10 Cabinet Lock Output: DO2 connect Lock to open the mailbox DO3 11 DO4 12 Function Cable Description V- Input 1 Power GND VIN Input 2 Positive power supply, range of volt: 9~24V Infrared Action Output 3 Output , Power Consumption : 24VDC / 600mA Reserved 4 --- LED Infrared Module(Optional) *Reading Range: Remote Control Sequential Control : Frequency-adjustable continuous pulse output Support Modbus RTU/Soyal Protocol Programmable Controller Fanless Embedded Computer Touch panel PC Industrial PC Mode I : Standard Modbus I/O Module Mode II : Mailbox Module AR-403-IO-0404M AR-403-IO-0202M-IR 1 2 3 4 5 6 7 8 9 10 11 12 12V GND LA+ DI3 DI4 DI2 DI1 DO3 DO4 DO2 DO1 LB- E/V5 Controller COM N.C. 12V 12V 12V GND Output GND GND Sensor Lock2 O 12VDC 725L485 Power Mailbox 1 Mailbox 2

Transcript of Universal I/O module(Option: Infrared sensor module) OO M ...

Page 1: Universal I/O module(Option: Infrared sensor module) OO M ...

V200415SOYALACCESS CONTROL SYSTEM

®

LED1LED2/3

DO1 ~ DO4 DI1 ~ DI4

DI4

DI4DO4

DO1DO2DO3DO4 DI3

DI3DO3

DI2

DI2DO2

DI1

DI1 L+ V+ V-L-DO1

RS485TxRx

POWERRS485DI1~4DO1~4

AR-403-IO-0001M-IR

(AR-403-IO-0001M-IR)

(AR-403-IO-0404M)

(AR-403-IO-0202M)(AR-403-IO-0404M)(AR-403-IO-0202M-IR)

1

159

2

2610

3

3711

4

4812

AR-403-IO-0001M-IR

AR-403-IO Series

3 ~ 6 cm

7 ~ 9 cm

10 ~ 15 cm

A

Y

B(Y0)

Universal I/O module(Option: Infrared sensor module)(Up to 24VDC/2000mA High Power MOSFET output)

AR-403-IO Series

Product

PIN Define

Infrared Module / I/O Module 1 Product

Indicator

Cable Instruction

Application of mailbox---Wiring Diagram

Wiring & Application

Indicator Color DescriptionLED1 Green POWERLED2 Green

RS485 TxRx Communication indicatorLED3 RedDO1

Red

DO1,Action indicator(Mailbox mode: letter indicator, blue LED)

DO2 DO2,Action indicatorDO3 DO3,Action indicatorDO4 DO4,Action indicatorDI 1

Green

DI1, Action indicatorDI 2 DI2, Action indicatorDI 3 DI3, Action indicatorDI 4 DI4, Action indicator

Sensor fordelivering letters

Indicator for letters inside

Door Sensor

Cabinet Lock

【AR-403-IO-0404M / AR-403-IO-0202M-IR】Cable Instruction:

【AR-403-IO-0001M-IR】Cable Instruction:

Function Cable AR-403-IO-0404M(Standard mode) Description

AR-403-IO-0202M-IR (Mailbox mode)

V- Input 1 Power GNDVIN Input 2 Positive power supply, range of volt: 9~24VRS-485 LA 3 RS-485 L+ contactRS-485 LB 4 RS-485 L- contact

DI1 5

Input point, triggered by the low electric potential

Delivering Letters Detection:When DI1 detect the letters are dropped, DO1 will be active to light on indicator.

DI2 6 Door Status Detection: When DI2 door sensor detects that the door is closed, the indicator will light off

DI3 7DI4 8

DO1 9MOSFET output, driven by 24VDC / 2A

Letters Indicator Output: When DI1 detects the letters are dropped and it will output 1Hz ON/OFF flashing signal; Stop the output till DI2 detects OFF-ON-OFF motion of the door.

DO2 10 Cabinet Lock Output: DO2 connect Lock to open the mailbox DO3 11DO4 12

Function Cable DescriptionV- Input 1 Power GNDVIN Input 2 Positive power supply, range of volt: 9~24VInfrared Action Output 3 Output , Power Consumption : 24VDC / 600mA Reserved 4 ---

LED

Infrared Module(Optional)

*Reading Range:

Remote ControlSequential Control : Frequency-adjustablecontinuous pulse outputSupport Modbus RTU/Soyal Protocol Programmable

ControllerFanless Embedded

ComputerTouch panel

PCIndustrial PC

Mode I : Standard Modbus I/O Module

Mode II : Mailbox Module

AR-403-IO-0404MAR-403-IO-0202M-IR

1

2

3

4

5

6

7

8

9

10

11

12

12VGND

LA+

DI3DI4

DI2DI1

DO3DO4

DO2DO1

LB-

E/V5 Controller

COM

N.C.

12V

12V

12V

GND

Output

GND

GND

Sensor

Lock2

O

12VDC 725L485Power

Mailbox 1

Mailbox 2

Page 2: Universal I/O module(Option: Infrared sensor module) OO M ...

V200415SOYALACCESS CONTROL SYSTEM

®

P1

P1 P2

P2

1

3

2 54

DI1D I2 DI1D I2

DI1

DI2

DI1

DI2

Universal I/O module(Option: Infrared sensor module)(Up to 24VDC/2000mA High Power MOSFET output)

AR-403-IO Series

Direction for use

DI1/3: Sensor When the letters are dropped, the sensor w i l l de tec t the motion.

DO2/4: Cabinet lockThe mailbox will open after the card is presented

DO1/3: Indicator The Indicator will light up when there are letters in the mailbox

DI2/4: Door SensorClose the door after taking out the letters. Door Sensor detects the door is closed and the indicator will be off.

Mode III : Multiple delay function

Mode IV/V : Rear Detection / Front Detection(Remain direction recognition)

Output 1: Falling edge Trigger (DO0)

Output 2: Rising edge Trigger (DO1)

Output 3: Toggle trigger (DO2)

Output 4: Non-distortion Pulse Delay (DO3)

Trigger

Trigger

Trigger

DelayTime

DelayTime

DelayTime

DelayTime

DelayTime A

DelayTime B

Trigger Trigger Trigger TriggerTrigger Trigger Trigger Trigger

※ Support Firmware version 401_MBox_V0209_190912.ISP and after.

Commview Setting steps:

Commview Software Update

Software Sett ing

(1) Select COM Port

(2) Click “Read” to get Node number

(3) Select Mode Standard----- Mode I: Standard Modbus I/O Module

Mailbox------- Mode II: Mailbox Module

Delay M-0--- Mode III: Multiple delay function

FF/RF falling----- Mode IV: Rear Detection

FF/RF rising----- Mode V: Front Detection

(4) Enter delay time (Mode 3/Mode 4) Make sure Nord number is consistent as above(5) Click “Write”, finish setting.

Please download software【SoyalDeviceTool】from Soyal website

Close thedoor of mailbox

FrontDetection

Sensing Coil Sensing Coil

RearDetection

FrontDetection

RearDetectionVehicle Detected

Vehicle Detected

Vehicle Detected