1
245.0 -30°C to +75°C 8.35 dB/100 m at 600 MHz Attenuation loss Min. 1000 MOhm.km Insulation resistance 8.7 Ohm/km DCR loop 15 x OD 75 +/- 3 Ohm PVC compound outer sheath, yellow PE compound bedding, black with PE mylar embed Railing of parallel bare copper outer conductor Foam PE insulation, white Solid bare copper conductor RoHS compliant Flame retardant in acc. to IEC 60332-1 Transmission and data networking Optimized up to 600 MHz in VHF/UHF bare copper for homogenous transmission Leaky coax constructed with railing of parallel subway, underground facility Suitable for use in tunnels, mining areas Signal transmission by RF leaky concept RG TUNNEL CABLE FC Strip stripping tool www.lappgroup.com Data communication systems UNITRONIC BUS HFFR L2/FIP FC UL/CSA Benefits “Fast Connect” (FC) cable design Application range Application where the combination of halogen free outer sheath with properties similar to polyurethane and enhanced flame retardancy is requested Product features Cable is UL/CSA approved (CMG) Halogen-free Flame retardant in accordance with IEC 60332-3 Oil-resistant The stated bit rates allow the following cable lengths (maximum) according of PROFIBUS User Organisation of one bus segment (Type A cable, PROFIBIS-DP): 93.75 kbit/s = 1200 m 187.5 kbit/s = 1000 m 500 kbit/s = 400 m 1.5 Mbit/s = 200 m 12.0 Mbit/s = 100 m Approvals (Norm references) Product Make-up Solid bare copper conductor PE core insulation Inner sheath, screening foil and copper braid- ing Thermoplastic outer sheath Colour: violet (RAL 4001) Technical data Approvals UL/CSA (CMG) Mutual capacitance approx. 28.5 nF/km Peak working voltage Max. 100 V (not for power applications) Impedance at 3 - 20 MHz: 150 +/- 15 Ohm Conductor resistance max. 100 Ohm/km Minimum bending radius 65mm Test voltage 1500 V core/core Range of temperature -30°C to +70°C Part number Article designation Number of pairs and con- ductor diameter in mm Outer diameter in mm approx. Copper index kg/km Weight kg/km approx. Stationary application 2170853 UNITRONIC BUS HFFR L2/FIP FC UL/CSA 1 x 2 x 0.64 8.0 30.1 75.0 Copper price basis: EUR 150 / 100 kg Our standard lengths, please visit: www.lappkabel.de/en/cable-standardlengths Packaging size: Coil ≤ 30 kg and ≤ 250 m, otherwise drum Please specify the desired packaging size (e.g. 1 x 500 m drum or 5 x 100 m coils) LAPPKABEL is a member of the INTERBUS CLUB user organization Accessories Info Benefits Application range Product features Approvals (Norm references) Product Make-up Technical data Minimum bending radius Characteristic impedance Part number Outer diameter in mm approx. Weight kg/km approx. 63 3803150 SLYWV7510BC Type Conductor diameter in mm 2.31 15.5 Range of temperature Homogenous Tranmission Leaky Coax Tunnel, Mining 75 Ohm Coupling loss 60 dB at 85 MHz 70 dB at 150 MHz

Transcript of UNITRONIC BUS HFFR L2/FIP FC UL/CSA€¦ · Insulation resistance 8.7 Ohm/km DCR loop 15 x OD 75...

Page 1: UNITRONIC BUS HFFR L2/FIP FC UL/CSA€¦ · Insulation resistance 8.7 Ohm/km DCR loop 15 x OD 75 +/- 3 Ohm PVC compound outer sheath, yellow PE compound bedding, black with PE mylar

245.0

-30°C to +75°C

8.35 dB/100 m at 600 MHzAttenuation lossMin. 1000 MOhm.kmInsulation resistance8.7 Ohm/kmDCR loop

15 x OD

75 +/- 3 Ohm

PVC compound outer sheath, yellow PE compound bedding, black with PE mylar embed Railing of parallel bare copper outer conductor Foam PE insulation, white Solid bare copper conductor

RoHS compliantFlame retardant in acc. to IEC 60332-1Transmission and data networkingOptimized up to 600 MHz in VHF/UHFbare copper for homogenous transmissionLeaky coax constructed with railing of parallel

subway, underground facilitySuitable for use in tunnels, mining areas

Signal transmission by RF leaky concept

RG TUNNEL CABLE

FC Strip stripping tool

www.lappgroup.com

Data communication systems

UNITRONIC BUS HFFR L2/FIP FC UL/CSA

■ Benefits▯

“Fast Connect” (FC) cable design

■ Application range▯

Application where the combination of halogen free outer sheath with properties similar to polyurethane and enhanced flame retardancy is requested

Product features▯

Cable is UL/CSA approved (CMG)▯

Halogen-free▯

Flame retardant in accordance with IEC 60332-3

Oil-resistant

The stated bit rates allow the following cable lengths (maximum) according of PROFIBUS User Organisation of one bus segment (Type A cable, PROFIBIS-DP):

93.75 kbit/s = 1200 m

187.5 kbit/s = 1000 m

500 kbit/s = 400 m

1.5 Mbit/s = 200 m

12.0 Mbit/s = 100 m

■ Approvals (Norm references)

     ■

Product Make-up▯

Solid bare copper conductor▯

PE core insulation▯

Inner sheath, screening foil and copper braid-ing

Thermoplastic outer sheath▯

Colour: violet (RAL 4001)

Technical dataApprovalsUL/CSA (CMG)Mutual capacitanceapprox. 28.5 nF/kmPeak working voltageMax. 100 V (not for power applications)Impedanceat 3 - 20 MHz: 150 +/- 15 OhmConductor resistancemax. 100 Ohm/kmMinimum bending radius65mmTest voltage1500 V core/coreRange of temperature-30°C to +70°C

Part number Article designation Number of pairs and con-ductor diameter in mm

Outer diameter

in mm approx.Copper index

kg/kmWeight

kg/km approx.Stationary application

2170853 UNITRONIC BUS HFFR L2/FIP FC UL/CSA 1 x 2 x 0.64 8.0 30.1 75.0

Copper price basis: EUR 150 / 100 kgOur standard lengths, please visit: www.lappkabel.de/en/cable-standardlengthsPackaging size: Coil ≤ 30 kg and ≤ 250 m, otherwise drumPlease specify the desired packaging size (e.g. 1 x 500 m drum or 5 x 100 m coils)LAPPKABEL is a member of the INTERBUS CLUB user organization

■ Accessories▯

Info

■ Benefits▯

■ Application range▯

Product features▯

■ Approvals (Norm references)

  

Product Make-up▯

Technical data

Minimum bending radius

Characteristic impedance

Part number Outer diameter

in mm approx.

Weight

kg/km approx.

63

▯▯

▯▯

3803150 SLYWV7510BC

Type Conductor diameterin mm

2.31 15.5

Range of temperature

▯ Homogenous TranmissionLeaky Coax

▯ Tunnel, Mining

75 Ohm▯

Coupling loss@@60 dB at 85 MHz@@70 dB at 150 MHz