UNIT 2A UNIT 3 UNIT 4 UNIT 5A UNIT 1D UNIT 1C UNIT 5B UNIT ...
Transcript of UNIT 2A UNIT 3 UNIT 4 UNIT 5A UNIT 1D UNIT 1C UNIT 5B UNIT ...
SERVICE AREA
+ 63
.495
1:18
UNIT 2AFFL 63.475
+ 63
.260
+ 63
.710
+ 63
.820
COMPOUNDUNIT 4FFL 64.000
UNIT 5AFFL 64.950
UNIT 5BFFL 64.950
+ 64
.010
+ 63
.710
+ 63
.600
+ 64
.525
+ 64
.525
65.1
30 +
+ 64
.935
+ 64
.810
+ 64
.560
+ 64
.500
+ 64
.305
+ 64
.355
+ 64
.300
+ 63
.750
+ 63
.310
+ 64
.475
64.5
15 +
+ 64
.515
+ 64
.950
+ 64
.950
+ 63
.775
+ 63
.995
+ 64
.560
+ 63
.225
+ 64.280
+ 63
.720
+ 63
.750
+ 63
.720
+ 63
.420
+ 63.880
+ 64.560
+ 63
.830
+ 63
.410
+ 63
.850
+ 62
.950
62.9
50 +
63.2
50 +
+ 64
.525
+ 63
.800
+ 63
.225
SERVICE SERVICE
SERVICE
+ 66.840
+ 66.270+ 66.390
+ 66.650
+ 66.240
+ 64.515
64.490 +
+ 64.870
FFL 64.525
1:40
EXISTING RIDGE LINE
EXISTING RETAINING WALLAND HANDRAIL
RAISED KERBAREA TORESTRICTVEHICULARACCESS
UNIT 3FFL 64.000
BETWEEN TOWN'S ROAD
63.770 +
+ 64.300
64.090 +
63.730 +63.610 +
6 CYCLESPACES
+ 67.290
RUN OVER AREA FORSERVICE TRUCKS
GRASS
GRASS
LOW LEVELPLANTING
+ 66.371
+ 64.450
+ 66.320
+ 67.450
65.890 + + 64.470
65.830 +
+ 67.050
DRDRDR
64.67
64.97
64.6764.70
64.62
64.87
64.79
65.8365.78
64.66
64.11
64.98
64.76
64.63
64.00
64.64
64.23 64.24
64.22
64.24
64.32
64.37
63.72
63.69
63.53
63.5763.57
BOLBOLSAP
BOLBOL SAP
KO
LP
KO
LP
LP
SAP LP
LP
KO
KO
KO KO
BOL
LP
WSV
WSVFH
MKR
TP
KO
LP
FH MKR
BOL
PIPE
BOL
BOL
BOL
BOL
BOL
BOL
LP
PIPE
LP LP LP LP LP LP
BOL BOL BOL
PT
PT
PT
PIPE
BRICK RTW
BRICK WALL
BL
BLBL BLBL
BLBL
BL
BL
LP
LP
LP
LP
LP
LP
LP LP
LPLP
MK
MK
TW
TW
TW
TW
TW
TW
TW
TL
TL
TL
CCTV
SPEED H
UM
P
SPEED H
UM
P
SPEED H
UM
P
SIGN
SIGN
SIGN
CB
CB
SV
SV
SV
SV
SV
SV
SV
LP
LP
LP
LP
RS
RS
RS
TL
TL
TL
SP
CCTV
NP
NP
SVSV
BLBL
LP
LP
LP
RS
AV
TW
TW
TW
TW
TW
TW
TW
TL
BL BL
BL
BLBL
BLBL
BLBL
BL
BLBL
BL
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
P
RS
RS
RS
RS
GATES
GP
GP
BIN
TW
TW
TW
TW
TW
TW
TW
TW
TW
TW
TW
TW
TW
TW
TWTW
TW
TWTW
NO
EN
TRY
post
post
post
post
post
post
8CYCLESPACES
EXISTING RIDGE LINE
FIRE EXIT /SERVICE
FIRE EXIT /SERVICE
64.230 +
63.770 +
+ 64.300
64.090 +
63.730 +63.610 +
64.490 +
SPWBTE
SPW
BT
SPW
BTE
318
318
MJ MJ MJ MJ MJ MJ MJ MJ
MJ
MJ
MJ
MJ
MJ
MJ
MJ
MJ
MJ
MJ
MJ
MJ MJ
MJMJ
MJ MJ
224 606224 809224 809 224 606 224 606 224 606
224 809
224 606
224 606224 809
224 606
224 606
224 606224 606224 809
224 606
224 809
224 606224 809
224 606
224 809
224 606224 809
224 606224 809
224 606224 809
224 606224 809
224 606
224 809
MJ
MJ
SP W BT ESP W BT E
SP
SP
SP
SP
SP
SP
SP
SP
MJ
MJ
MJ
MJ
1
3
4
50
SP
PPB 175
PPB 225 PPB 225
PPB 175
PPB 225 PPB 225
PPB 225
ST1 250
ST1 250
ST1 250
ST1 250
ST1 250
ST1 250
ST1 250
ST1 250 ST1 250
PPB 200
PPB 175
PPB 150
ST1 250ST1 250 ST1 250 ST1 250
PPB 150
ST1 250
PPB 200
ST1 250
ST1 275
ST1 275
ST1 275
ST1 275
ST1 275
ST1 275
PPB 175
ST1 275
PPB 175
ST1 275
ST1 275
ST1 275
ST1 275
ST1 275 ST1 275 ST1 275 ST1 275 ST1 275 ST1 275 ST1 275 ST1 275 ST1 275 ST1 275
MJ
SPASPASPASPA
SPA
SPA
SPA
SPASPA
SPA
SPA
SPA
SPA
SPA
2
MJ MJ
MJMJ
MJ
MJ
WEBT
SP
ST1 275
E
PPB 125
SHX 150
224 606
224 809
224 606
224 809
E
RWP
224 606
224 606224 606
224 809
+ 66.370
FIRE EXIT ROUTE /SERVICE ROUTE
FIRE EXIT /SERVICE
FIRE EXIT /SERVICE
FIRE EXIT /SERVICE
2.7m HIGH CORAL RAG WALLRETAINED AS EXISTING 3m HIGH CORAL RAG WALL
RETAINED AS EXISTING
1.6m HIGH CORAL RAGWALL RETAINED AS EXISTING
64.490 +64.490 +
RYM
ER'S
LA
NE
KEEPC
LEAR
UNIT 1DFFL 64.560
UNIT 1CFFL 64.525
UNIT 1BFFL 64.525
UNIT 1AFFL 64.525
UNIT 1EFFL 64.525
UNIT 1FFFL 64.525
UNIT 1GFFL 64.525
UNIT 2DGF 185sqm(2,000sqft)
UNIT 2BGF 341sqm(3,670sqft)
UNIT 2CGF 232sqm(2,500sqft)
EXISTING PARTITIONWALL RETAINED
EXISTING GOODSDOOR RETAINED
NEW GOODSDOOR
PROPOSED JUMBOPARTITION
EXISTING GOODSDOOR RETAINED
PROPOSED JUMBOPARTITION
PROPOSEDSWING DOORS
EXISTING GLAZEDDOOR RETAINED
PROPOSEDSWING DOORS
EXISTING CURTAINWALL REMOVED
PROPOSED GLAZING
NEW GOODSDOOR
EXISTINGENTRANCE/EXIT
+63.465
+63.530
+63.465
63.350+
63.430+
FFL 63.475
FFL 63.475
+63.450 +63.490
63.320+
63.575+
+63.450
+63.465+63.465+63.465
+E63.705
E63.700+ +63.730
63.465+
FFL 63.475 FFL 63.475 FFL 63.475
FFL 63.475
FFL 63.475
FFL 64.000
3000.1128
1500.0000
1199.9811
63.500+
63.85
63.84
63.90
63.52
63.72
63.85
EXISTING ESTIMATEDAMENITY AREA RETAINEDIF REQUIRED
DIS WC
MALE WC
CANTEEN OFFICE
EXISTING WALL TO BEREMOVED
EXISTING WALL TO BEREMOVED
SKIPS
2 x Car spaces
& Shrubs
Plants
Tarm
ac
Tarm
ac
Tarm
ac
Parkin
gParkin
gParkin
gParkin
gParkin
gParkin
g
Pavin
g
& Shrubs
Plants
& Shrubs
Plants
Pavin
g
Pavin
g
Pavin
g
Bin
Bin
Pavin
gRamp Up
Up
Up
Up
Up
Up
Bench
Gravel
IC
Gy
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
Boll
ICU
Re
Servicing corridor
Warehouse
Canteen
Staff WC
(A)
Staff WC
(B)C
loaksC
ashM
anagersC
ustomer
WC
BakeryFreezer
Chiller
Bakery
Utility
Sales escape corridorEN
TRAN
CE
LOBBY
GOODS IN
64.95
S3 Road view signCorporate logo vinyl to be applied to signageframe, face fixed to building. Sign position anddimensions subject to confirmation.
S1 Primary store signCorporate logo 'bubble' sign, to beinternally illuminated, fixed tobuilding structure.
S2 Poster display unitIlluminated poster display unit withstainless steel frame
KEY
Application boundary9.08 acres / 3.68 hectares
Free-standing sign
Wall mounted sign
CLIENTNo. Date
PROJECT
TITLE
DRAWING STATUS
DRAWING NO.JOB NO. REV
DRAWN
SCALE
DATE
CHECKED
Description Drwn/Chkd By
This drawing is copyright of WCEC Group Ltd trading as Whittam CoxArchitects, and shall not be reproduced nor used for any other purposewithout the written permission of the Architects. This drawing must beread in conjunction with all other related drawings and documentation.It is the contractors responsibility to ensure full compliance with theBuilding Regulations. Do not scale from this drawing, use figureddimensions only. It is the contractors responsibility to check and verifyall dimensions on site. Any discrepancies to be reported immediately.IF IN DOUBT ASK.Materials not in conformity with relevant British or EuropeanStandards/Codes of practice or materials known to be deleterious tohealth & safety must not be used or specified on this project.
Whittam Cox Architects - Disclaimer:
Chesterfield / 01246 260261London / 020 3388 0019Leeds / 0113 468 2450
whittamcox.com
©
Lidl Great Britain Limited
Templars Retail ParkOxford
Proposed Signage Locations
Planning
WF DC1:500 @ A1September 2021
200180 PL-02 B
A 13/09/21 Application boundary updated to reflect OS WF/DC
B 13/09/21 Signage annotation amended WF/DC