UNIT 2 Mechatronics

35
1 UNIT – II SENSORS AND TRANSDUCERS 1.0 INTRODUCTION: v Sensor is used to produce a varying signal according to the quantity being measured. v Sensor is an element in a mechatronic system which acquires a physical parameter and changes it into signal that can be processed by the system. v The active element of a sensor is known as transducer. v Transducer converts the measured quantity, property (or) condition into a usable electrical output. v The mechatronic system requires sensors to measure physical quantities such as position, distance, force, strain, temperature, vibration and acceleration. Simply sensors are also called transducers. 2.0 PERFORMANCE TERMINOLOGY: v The function of the sensor (or) transducer is to sense (or) detect a parameter such as pressure, temperature flow, motion, resistance, voltage, current and power. v The sensor should be capable of faithfully and accurately detecting any changes that occur in the measured parameter. v The performance of transducers can be defined by using the following terms: 1. Range and span 2. Error 3. Accuracy 4. Sensitivity 5. Hysteresis error 6. Non linearity error 7. Repeatability/Reproducibility 8. Reliability 9. Stability 10. Dead band/time 11. Resolution 12. Backlash 13. Output impedance

description

Mechatronics

Transcript of UNIT 2 Mechatronics

Page 1: UNIT 2 Mechatronics

1

UNIT – IISENSORS AND TRANSDUCERS

1.0 INTRODUCTION:v Sensor is used to produce a varying signal according to the quantity being

measured.

v Sensor is an element in a mechatronic system which acquires a physicalparameter and changes it into signal that can be processed by the system.

v The active element of a sensor is known as transducer.

v Transducer converts the measured quantity, property (or) condition into ausable electrical output.

v The mechatronic system requires sensors to measure physical quantities suchas position, distance, force, strain, temperature, vibration and acceleration.Simply sensors are also called transducers.

2.0 PERFORMANCE TERMINOLOGY:

v The function of the sensor (or) transducer is to sense (or) detect a parametersuch as pressure, temperature flow, motion, resistance, voltage, current andpower.

v The sensor should be capable of faithfully and accurately detecting anychanges that occur in the measured parameter.

v The performance of transducers can be defined by using the following terms:

1. Range and span2. Error

3. Accuracy4. Sensitivity

5. Hysteresis error6. Non linearity error

7. Repeatability/Reproducibility8. Reliability

9. Stability10. Dead band/time

11. Resolution12. Backlash

13. Output impedance

Page 2: UNIT 2 Mechatronics

2

1. Range and Span:v The range of a transducer defines the limits between which the input can vary.

v The difference between the limits (maximum value - minimum value) isknown as span.

v For example a load cell is used to measure force. An input force can vary from20 to 100 N. Then the range of load cell is 20 to 100 N. And the span of loadcell is 80 N (i.e., 100-20)

2. Error:

v If the transducer is ideally designed and made from appropriate materials withideal workmanship, then output will indicate the true value. But in actualpractice the output of the transducer will deviate from the true value.

v The algebraic difference between the indicated value and the true value of themeasured parameter is termed as the error of the device.

v Error = Indicated value — true value

v For example, if the transducer gives a temperature reading of 30°C when theactual temperature is 29°C, then the error is + 1°C. If the actual temperature is3 1°C, then the error is — 1°C.

3. Accuracy:

v Accuracy is the extent to which the value indicated by the measurementsystem would be wrong.

v Accuracy is the summation of all possible errors that are likely to occur.

v For example, a thermocouple has an accuracy of ± 1°C. This means thatreading given by the thermocouple can be expected to lie within + 1°C (or) —1°C of the true value.

v Accuracy is also expressed as a percentage of the full range output (or) full-scale deflection.

v For example, a thermocouple can be specified as having an accuracy of ±4 %of full range output. Hence if the range of the thermocouple is 0 to 200°C,then the reading given can be expected to be within + 8°C (or) — 8°C of thetrue reading.

4. Sensitivity:v The sensitivity is the relationship showing how much output we can get per

unit input.

v ie sensitivity = Output / Input

5. Hysteresis error:v When a device is used to measure any parameter plot the graph of output Vs

value of measured quantity.v First for increasing values of the measured quantity and then for decreasing

values of the measured quantity.v The two output readings obtained usually differ from each other.

Page 3: UNIT 2 Mechatronics

3

Fig.1.1 Hysteresis error

v This is because of a certain amount of internal (or) external friction in theresponse of the sensing element.

v The maximum difference in between any part of output readings so obtained isknown as hysteresis error.

v The hysteresis error can be reduced by proper design and selection of themechanical components, introducing greater flexibility and providing suitableheat treatment to the materials.

6. Non-linearIty error:v A linear relationship is assumed between the input and output and hence, a

straight line is drawn in the graph as shown here.

Fig.1.2

v Some transducers, do not have linear relationship and errors occur as a resultof the assumption of linearity.

v The error is defined as the maximum difference from the straight line.

v There are three methods to find the the numerical error. They are namely,

(i) End range value

(ii) Best straight line for all values(iii) Best straight line, through zero point.

v In the first method, (fig 1.2), the straight line is drawn by joining the outputvalues at the end points of the range.

Page 4: UNIT 2 Mechatronics

4

v In the next method, the straight line is drawn by using the method of leastsquares to determine the best fit line by considering all data values are in error.Refer fig (1.3).

v In the last method, the straight line is drawn by using the method of leastsquares to determine the best fit line which passes through the zero point.

Fig.1.3 Fig.1.4

7. Repeatability/Reproducibility:

v The repeatability and reproducibility of a transducer are its ability to give thesame output for repeated applications of the same input value.

v Repeatability is also defined as the measure of the deviation of test resultsmean value.

8. Reliability:v The reliability of a system is defined as the possibility that it will perform its

assigned functions for a specific period of time under given conditions.

v The reliability of a device (or) system is affected not only by the choice ofindividual parts in system but also by manufacturing methods, quality ofmaintenance and the type of user.

9. Stability:v The stability of a transducer is its ability to give the same output when used to

measure a constant input over a period of time.

v The term drift is the change in output that occurs over time.

v The drift can be expressed as a percentage of the full range.

v Zero drift means if there is change in output when there is zero input.

10. Dead band / time:v There will be no output for certain range of input values. This is known as

dead band. There will be no output until the input has reached a particularvalue.

v The length of time from the application of an input until the output begins torespond and change is known as Dead time.

Page 5: UNIT 2 Mechatronics

5

11. Resolution:v Resolution is defined as the smallest increment in the measured value that can

be detected.

v The resolution is the smallest change in the input value which will produce anobservable change in the input.

v Resolution is also known as the degree of fineness with which measurementscan be made.

v For example, if a micrometer with a minimum graduation of 1mm is. used tomeasure to the nearest 0.5 mm, then by interpolation, the resolution isestimated as 0.5 mm.

12. Backlash:v Backlash is defined as the maximum distance (or) angle through which any

part of a mechanical system can be moved in one direction without causingany motion of the attached part.

v Backlash is an undesirable phenomenon and is important in the precisiondesign of gear trains.

13. Output Impedance:v Before defining impedance, we should know about Ohm’ s law.

v Ohm’ s law is used to define the relationship between voltage V, Current I andResistance R.

(i.e.,) V=IR

v Ohm’ s law can be extended to the AC circuit analysis of resistor, capacitorand inductor elements as

v=ZI

where Z is called impedance of the elements. So impedance is similar toresistance.

v The sensors produce electrical output.

v When these sensors are interfaced with an electronic circuit, it is necessary toknow the output impedance.

v This impedance is connected in either series (or) parallel with that circuit andthe inclusion of the sensor will modi1 the behaviour of the system to which itis connected.

3.0 DISPLACEMENT, POSITION AND PROXIMITY

Displacement Sensors:

The measurement of the amount by which some object has been moved.1. Potentiometer,2. Resistance strain gauge,3. LVDT,4. Push pull displacement sensor.

Page 6: UNIT 2 Mechatronics

6

Position Sensors:v The determination of the position of some object with reference to some

reference point.1. Photo electric sensors,2. H sensors.

Proximity Sensors:

v Used to determine when an object has moved to within some particular criticaldistance.1. Pneumatic proximity sensor,2. Eddy current proximity sensor,3. Inductive proximity switch,4. Micro switch,5. Reed switch.

Factors to be considered while selecting displacement, Position and Proximitysensors:

1. The accuracy required2. The resolution required3. The size of the displacement4. Displacement type (linear or angular)5. The cost and material made

1. Contact Sensors:

v The measured object is mechanical contact with the sensor.v In the contact sensors there is a sensing shaft which is direct contact with the

object being monitored.v The movement of the shaft may be used to make changes in electrical voltage,

capacitance, resistance.

2. Non-contact sensors:

v The measured object is no physical contact between the measured object andthe sensor.

v In the non-contact sensors the measured object causing a change in the airpressure in the sensor, or a change in inductance or capacitance.

3.1 DISPLACEMENT SENSORS:

v A potentiometer can be used to convert rotary or linear displacement to avoltage.

v The potentiometers can be classified into three types.

Page 7: UNIT 2 Mechatronics

7

1. Potentiometer Sensor

v Potentiometers consists of a resistance element with a sliding contact and thesliding contact can be moved over the length of the element. This slidingcontact is called Wiper.

v The motion of the sliding contact may be linear or rotational.v The Fig.1.5 shows the linear potentiometer and the Fig.1.6 shows the rotary

potentiometer.v The rotary potentiometer consists of a circular wire-wound track over which a

rotatable sliding contact can be rotated.v The wire-wound track may be single turn or helical turn.

Displacement and Position Sensor Types:

The displacement and position sensors are grouped into:1. Contact sensors2. Non-contact sensors1. Rotary2. Linear3. Helical potentiometers

Fig.1.5

Fig.1.6

Page 8: UNIT 2 Mechatronics

8

Fig.1.7

Advantages of Resistance Potentiometers:1. They are simple and in expensive,2. Electrical efficiency is high,3. Simple in operation.4. Useful for measurement of large amplitudes of displacement

2. Strain Gauged Element:

v The change in length divided by original length is called strain.v The strain gauge consists of metal wire, metal foil strip. When subject to

strain, the resistance ‘ R’ changes, and the change in resistance L isproportional to strain E.

where G is a constant (gauge factor).v In the Fig.1.9 the strain gauge is attached to flexible elements in the form of

cantilevers, rings, U shapes.v When the flexible element is bent, as a result of this the electrical resistance

will change due to force applied by a contact point.v The change in resistance is the measure of displacement.v The Fig.1.8 and 1.9 shows the strain gauges and strain gauged elements.v The major types of strain gauges are

I. Metal wire strain gauges,2. Metal foil strain gauges,

Page 9: UNIT 2 Mechatronics

9

3. Semiconductors strain gauges.

Fig.1.8

Fig.1.9

Page 10: UNIT 2 Mechatronics

10

v In Metal Wire Strain Gauges a wire stretched between two points in aninsulating medium such as air.

v The wires may be made of various copper nickel, chrome nickel or nickel ironalloys. They are about 0.003 mm in diameter and gauge factor of 2. The lengthof wire is 25 mm or less.

v In Metal foil strain gauge the foil is usually made up of constantan, and it isetched in a grid pattern onto a thin plastic backing material, usually polyimide.The foil is terminated at both ends with large metallic pads.

v The size of the entire gauge is very small and has a length of 5 mm to 15 mmlength.

v In Semiconductor strain gauges the p type and n type silicon semiconductorsare used.

v The semiconductor strain gauges have the gauge factors of about +100 or —100. In p-type gauges resistance increases with tensile strain. While in n-type,resistance decreases. Typical thickness is about 0.25 mm and effective lengthrange from 1.25 to 12 mm.

4. Linear Variable Differential Transformer (LVDT)

Fig.1.10

Fig.1.11

Page 11: UNIT 2 Mechatronics

11

v It consists of three coils symmetrically spaced along an insulated tube.v The central coil is primary and other two are secondary.v A magnetic core is moved through the central tube, so that the displacement

being monitored.v When voltage is supplied to the primary coil, alternating e.m.f.s are induced in

the secondary coils.v Suppose the magnetic core is in central, the e.rn.f. induced in each coil is same

because of magnetic material in each coil is same and oppose to each other. Sothere is no output.

v If the core is displaced from the central position there is a greater amount ofmagnetic core in one coil than the other. This will create a higher e.m.f. in onecoil and lesser e.m.f. in the other coil. This will make a net difference in twoe.m.f.s and the displacement being monitored.

v The formulas which are used in LVDT are:1. The e.m.f.s induced in the two secondary coils 1 and 2 are:

where K1, K2 are degree of coupling between the primary and secondarycoils.

Advantages of L VDT:1. High range2. Friction and electrical isolation3. Low hysteresis4. Power consumption is less.

5.Push Pull Displacement Sensor:

v It has three plates with the upper pair forming one capacitor and the lower pairforming another capacitor.

v There is a non-linear relationship form between the change in capacitance ACand the displacement X.

v The displacement moves the central plate between the two other plates.v The result of this, the central plate moving downwards and to increase the

plate separation of the upper capacitor and decrease the separation of the lowercapacitor.

v Therefore, the capacitance of a parallel plate capacitor is given by

where C1 is in one arm of an a.c. bridge,

Page 12: UNIT 2 Mechatronics

12

C2 is in an other arm of an a.c. bridge.

= Relative permittivity of the dielectric between the= Permittivity of free space constant,

x = Displacement,A = The area of overlap between the two plates,d = The plate separation.

3.2 POSITION SENSORSv position sensors report the position of an object with respect to a reference

part.v The information can be an angle as in many degree a dish antenna has turned.v The following are the position sensors.

1. Photoelectric Sensorsv It is used to detect the object by breaking a beam of light (Refer Fig.1.12(a))

or radiation falling on a device or by detecting the light reflected back by theobject (Refer Fig.1.12(b)).

Fig.1.12

2. Hall effect Sensors

v Hall effect: Hall effect is defined as when a beam of charged particles passesthrough magnetic field, the beam is deflected from its straight line path due tothe forces acting on the particles.

v A current flowing in a conductor like a beam is deflected by a magnetic field.

Fig.1.13

v The working principle of a Hall effect sensor is that if a strip of conductingmaterial carries a current in the presence of a transverse ngne1i shown inFig.1.13.

Page 13: UNIT 2 Mechatronics

13

v The difference of potential is produced between the opposite edges of theconductor. The magnitude of the voltage depends upon the current andmagnetic field.

v In the Fig. the current is passed through leads 1 and 2 of the strip. The outputleads connected with Hall strip.

v When a transverse magnetic field passes through the strip the voltagedifference occur in the output leads.

v The hail effect sensor have the advantages of being able to operate as switchesand it operate upto 100 KHz.

Fig.1.14

Applications of Hall Effect Sensors:

1. It is used as a Magnetic to electric transducer.2. It is used for the measurement of the position or displacement of a structuralelement.3. It is used for measurement of current.4. It is used for measurement of power.

Digital Optical Encoder:

v A digital optical encoder is a device that converts motion into a sequence ofdigital pulses.

v By counting or decoding these bits and the pulses can be converted intorelative or absolute position measurements.

v Encoders are in Rotary, linear configurations.v The Rotary encoders are in two forms.

1. Absolute encoder2. Incremental encoder.

1. Absolute Encoder:

v The absolute encoder is designed to produce a digital word that distinguishes‘N’ distinct positions of the shaft.

Page 14: UNIT 2 Mechatronics

14

Fig. 1.15. Components of an optical encoder

v The Fig.1.15 shows the basic form of an absolute encoder.v The rotating disc has four concentric circles of slots and four sensors to detect

the light pulses.v The slots are arranged in such a way that the output is made in the binary

code.v The number of bits in the binary number will be equal to the number of tracks.v The most common types of numerical encoding used in the absolute encoder

are gray and natural binary codes.v To illustrate the action of an absolute encoder, the gray code and natural

binary code disk track patterns for a simple 4 track (4-bit) encoder is shown inFig.1.16

Fig. 1.16 4-bit gray code absolute encoder disk track patterns

2. Incremental Encoder:v Working: A beam of light passes through the slots in a disc and it is detected

by a suitable light sensor.v When the disc is rotated, the output is shown in terms of pulses and these

pulses being proportional to the angle of disc rotation.

Page 15: UNIT 2 Mechatronics

15

Fig. 1.17. Incremental encoder

v So the angular position of the disc is determined by the number of pulsesproduced. In the above Fig. three tracks and three sensors are used.

v The inner track has just one hole and other two tracks have a series of equallyspaced holes.

v The angle is determined by the number slots on the disc.

3.3 PROXIMITY SENSOR

v A proximity simply tells the contra! system whether a moving part is at acertain place.

v Proximity sensors come under the non contact type sensors.

v The following are the some of the proximity sensors.

1. Pneumatic proximity sensor:v Working: Low-pressure air is allowed and to escape through a port which is

placed in the front position of the sensor. This escaping air reduces thepressure in the nearby sensor output port, when there is no close by object.

Fig. 1.18. Pneumatic proximity sensor

Page 16: UNIT 2 Mechatronics

16

v If there is a close by object means the air will not escape readily, so thepressure increases in the sensor output port. This output from the sensordepends on the proximity of objects.

2. Eddy current proximity sensors:

Fig. 1.19. Eddy current sensor

v Working: When alternating current is supplied to the coil means thealternating magnetic field is produced. If there is a metal object in closeproximity to this alternating magnetic field the eddy current is induced in it.This eddy current will produce a magnetic field themselves and the impedanceof the coil changes the amplitude of the alternating current.

v The above Fig. shows the basic form of such sensor and it is used for thedetection of non-magnetic conductive materials.

3. Inductive proximity switch:v It is used for the detection of metal objects and it consists of a coil wound

around a core.v The metal object is close to the coil means it will produce a inductance change

in the coil. This inductive change is being monitored.

4. Microswitch:v It is used for determining the presence of an item on a conveyor belt and this

might be actuated by the weight of the item on the belt depressing the belt by aspring loaded platform nearer to the sensor the presence of item in theconveyor is determined.

v The closeness of switch is done by movement of this spring loaded platform.

Fig. 1.20. Microswitch

5. Reed switch:v It is a non-contact proximity switch. It is used for checking the closure of

doors.v It consists of two magnetic switch contacts sealed in a glass tube.

Page 17: UNIT 2 Mechatronics

17

Fig. 1.21. Reed switch

v When a magnet is brought close to the switch, the magnetic reeds are attractedeach other and close the switch contacts.

4.0 VELOCITY AND MOTION:

To detect and monitor the velocity and motion the following sensors are used.

4.1 VELOCITY MEASUREMENTv Velocity sensors or tachogenerators are devices that give an output

proportional to angular velocity.v These sensors find wide application in motor speed control systems.v The following are the various velocity sensors.

1. Electro Magnetic Transducer,v The most commonly used transducer for measurement of linear velocities is

electromagnetic transducer.v The electromagnetic transducers are classified into two categories.

1. Moving Magnet Type:2. Moving coil type.

v In moving magnet type the sensing element is a rod that is rigidly coupled tothe device whose velocity is being measured.

v This rod is a permanent magnet. This permanent magnet is surrounded by acoil.

v The motion of the magnet induces a voltage in the coil and the amplitude ofthe voltage is directly proportional to the velocity.

Fig. 2.22. Moving magnet type transducer

Page 18: UNIT 2 Mechatronics

18

2. Moving coil type velocity transducer:

v It is operated through the action of a coil moving in a magnetic field.v A voltage generated in the coil is proportional to the velocity of the coil.v This is a more satisfactory arrangement due to it forms a closed magnetic

circuit with a constant air gap and the device is contained an antimagnetic casewhich reduces the effects of stray magnetic field.

Fig. 2.23. Moving coil type velocity transducer

3. Tachogenerators:

v A sensor that converts speed of rotation directly into electrical signal is calleda tachogenerator.

v It is used to convert angular speed into a directly dependent voltage signal.(a) Toothed Rotor Variable Reluctance Tachogenerator:

v It is used to measure angular velocity.v This tachogenerator consists of a metallic toothed rotor mounted on the shaft

whose speed is to be measured.v A magnetic pick up is placed near the toothed rotor and this magnetic pick up

consists of a housing, and the housing containing a small permanent magnetwith a coil wound around it.

v When the rotor rotates, the reluctance of the air gap between pickup and thetoothed rotor changes and the rise in e.m.f. is induced in the pickup coil.Finally the output is in the form of pulses and wave shapes.

v The pulses induced depend upon the number of teeth in the rotor and therotational speed. When the speed is known, the rotational speed is calculatedby measuring the frequency pulses.

Page 19: UNIT 2 Mechatronics

19

v

Fig. 2.24. Toothed rotor tachometer generator

v Suppose the rotor has ‘ n’ teeth and the speed of rotation is ‘ N’ r.p.s. andnumber of pulses per second is ‘ p’ .

v The number of pulses per revolution = ‘ n’ = n

The advantage of toothed rotor variable reluctance tachogenerator is the informationfrom this device can be easily transmitted and easy to calibrate.

4. A. C. Generator Form of Tachogenerator:v It consists of rotor, which rotates with the rotating shaft and a coil.v When the coil rotates in the magnetic field the e.m.f. is induced.v The magnet may be in the form of stationary permanent magnet or

electromagnet.v The frequency of this alternating e.m.f. is used to measure the angular

velocity.v The output voltage is rectified and it is measured with a permanent magnet

moving coil (PMCC) voltmeter.

Fig. 2.25. A.C Tachometer generator

Page 20: UNIT 2 Mechatronics

20

4.2 MOTION SENSORS1. Stroboscope:v Stroboscope is a simple portable manually operated device for periodic or

rotary motions measurement.v It is a variable frequency flashing light instrument and the flashing is set by

the operator.v If a strong light is caused to flash on a moving object at the time each flash

occurs. The stroboscope occupies a given position, and the object will appearto be stationary.

v The flashing light whose frequency can be varied and controlled, and thissource is called strobotron.

2 Pyroelectric Sensors:v It consists of a polarised pyroelectric crystal with thin metal film electrodes on

opposite faces. (Pyro electric materials, e.g., lithium tantalate are crystallinematerials which generate charge in response to heat flow. When such materialsheated to about 610°C in an electric field, the electric dipoles within thematerial line up and it becomes polarised as shown in Fig.).

v Due to the crystal is polarised with charged surfaces, the ions are drawn fromthe surrounding air and electrons from any measurement circuit is connectedto the sensor to balance the surface charge as shown in Fig.

v For measurement of a human or heat source motion, the sensing element hasto differentiate between general background heat radiation and a moving heatsource. For that a single pyroelectric sensor is not capable to use and dualpyroelectric sensors are used as shown in Fig.

v In this dual pyroelectric sensors the sensing element has the one frontelectrode and two back electrodes. When two sensors being connected meansboth sensors are receive the same heat signal and their outputs are cancelled.

Fig. 2.26. Pyroelectric sensors

Page 21: UNIT 2 Mechatronics

21

v Suppose a heat source moves from its position means the heat radiation movesfrom one of the sensing elements to the other, then the current is alternates inone direction first and then reversed to the other direction second.

v A moving human gives an alternating current of 1O A. When the infraredradiation is incident on the dual pyroelectric sensor material and changes itstemperature, the polarisation in the crystal is reduced. A focusing device isneeded to direct the infrared radiation onto the sensor.

5.0 FLUID PRESSURE SENSORSv The devices which are used to monitor fluid pressure in industrial processes is

diaphragms, bellows, capsules and tubes.v The types of pressure measurements required are

(1) Absolute pressure measurement,(2) Differential pressure measurements.

v In absolute pressure measurements the measurement is related to vacuumpressure (zero pressure) and in differential pressure measurement thedifference in pressure is measured. The types of pressure measurement devicesare discussed below.

1. Diaphragmsv In this the pressure to be measured is applied to the diaphragm, causing it to

deflect, and the deflection being proportional to the applied pressure. Thismovement can be monitored by some form of displacement sensor. (Examplefor displacement sensor is strain gauge) and it is shown in Fig.2.27.

Fig. 2.27. Diaphragm pressure gauge

Page 22: UNIT 2 Mechatronics

22

Fig. 2.28. Diaphragm type strain gauge pressure transducer

v A specially designed strain gauge is also used for measuring pressure and itconsisting of four strain gauges with, two measuring the strain in acircumferential direction while remaining two measure strain in a radialdirection. The four strain gauges are connected to form the arms of awheatstone bridge a shown in Fig.2.28.

v The deflection at any point is shown in terms of +ve and —ye sign. The stressdistribution on the diaphragm surface is almost ideal for practical purposes,since both compressive and tensile stresses exit. So this will allow the use of afour arm wheatstone bridge where all the gauges are active and consequentlythere is a large output.

v The strain gauges I and 4 are placed at close to the centre and oriented to readtangential strain and its value is +ve maximum at this point.

v The gauges 2 and 3 are oriented to read radial strain and it is placed close tothe edge as possible.

2. Bellowsv A metallic bellows is a series of circular parts as shown in Fig.2.29 and the

parts are formed or joined in such a manner that they are expanded orcontracted axially by change in pressure.

Fig. 2.29. Bellows

Page 23: UNIT 2 Mechatronics

23

v The Fig.2.30 shows the bellows can be combined with a LVDT to give apressure sensor with an electrical output.

v The bellows are made up of materials like stainless steel, phosphor bronze,nickel, rubber and nylon.

v The output pressure is calibrated through the LVDT.

Fig. 2.30. L VDT with bellows

3. Capsule

Fig. 2.31. Capsule

v Capsules are one of the pressure measuring device and it can be considered tobe just two corrugated diaphragms combined and give even greater sensitivity.

v The capsules are more sensitive in measuring pressure.

4. Tube Pressure Sensors

Fig. 2.32. Tube pressure sensors

v In tube pressure measurement the increase in pressure in a tube is cause thetube in circular cross-section. It is shown in the above Fig. The tubes havinggreater sensitivity while the pressure increases.

v The tubes are made up of stainless steel and phosphor bronze.

5. Tactile Sensorv It is one form of pressure sensor and it is used to determine the pressure in

Robotics in such a form fingertips of robotics contact with the object.

Page 24: UNIT 2 Mechatronics

24

v These type of sensors also used in ‘ touch display screens’ where physicalcontacts to be sensed.

v The above Fig.2.33 shows the one form of tactile sensor.v It uses piezo electric polyvinylidene fluoride (PVDF) film.v There are two layers of such film is used and it is separated by a soft film

which transmits vibrations.

Fig. 2.33. PVDF tactile sensor

v The alternating voltage is supplied in the lower PVDF film and this results inmechanical oscillations of the film.

v The intermediate film transmits these vibrations to the upper PVDF film.v Due to the piezoelectric effect the vibrations formed are cause an alternating

voltage to be produced across the upper film.v So the pressure is applied to the upper PVDF film and its vibrations are

affected the output voltage.

6. Piezoelectric sensor

Fig. 2.34. Sensor equivalent circuit

v The electrical circuit for a piezo electric sensor is a charge generator inparallel with capacitance Cs and in parallel with Resistance Rs.

v The effective circuit is as shown by the Fig. when the sensor is connected via acable of capacitance C and resistance RA.

v The sensor is charged subject to pressure change and the capacitor willdischarge with time. The discharge time depends on the time constant of thecircuit.

LIQUID FLOW SENSORSv There are many devices used to measure the liquid flow.v The basic principle in measuring flow is the fluid flowing through the pipe per

second is proportional to square root of pressure difference.v The following flow measuring devices are used to measure the liquid flow.

Page 25: UNIT 2 Mechatronics

25

1. Turbine Flowmeterv The Fig.2.35 shows the turbine flowmeter and it consists of a multi-bladed

rotor which is supported in the pipe along with the flow occurs.v The rotor rotation depends upon the fluid flow and the angular velocity is

proportional to the flow rate.v The rotor rotation is determined y the magnetic pick-up, which is connected to

the coil.v The revolution of the rotor is determined by counting the number of pulses

produced in the magnetic pick up. The accuracy of this instrument is ± 3%.

Fig. 2.35.

2. Orifice Platev It is a simple disc with a central hole and it is placed in the tube through which

the fluid flow.

Fig. 2.36. Orifice plate

v From the above Fig.2.36 the pressure difference measured between a pointequal to the diameter of the tube upstream and half the diameter of downstream.

v The accuracy of this instrument is ±1.5%.

LIQUID LEVEL MEASUREMENTThe liquid level measurement is done by using1. Differential pressure sensor and2. Float system.

Page 26: UNIT 2 Mechatronics

26

1. Differential Pressure Sensorv In this the differential pressure cell determines the pressure difference between

base of the liquid and atmospheric pressure.v The differential pressure sensor can be used in either form of open or closed

vessel system.

Fig. 2.37.

2. Float Systemv In this method the level of liquid is measured by movement of a float.v The movement of float rotates the arm and slider will move across a

potentiometer.v The output result is related to the height of the liquid.

Fig. 2.38.

6.0 TEMPERATURE SENSORSv Temperature measurements are amongst the most common and the most

important measurements made in controlling industrial processes.v Changes that are commonly used to monitor temperature are, the expansion or

contraction of solids, liquids or gases, the change in electrical resistance ofconductors, semiconductors and thermoelectric e.m.f.s. The control systemwhich are used to measure the temperature is as follows

1 Thermocouplesv The most common electrical method of temperature measurement uses the

thermocouples.v The basic principle of this is, if two different metals are joined together, a

potentiometer difference occurs across the junction.v The potential difference depends on the metals used and the temperature of the

junction.v When both junctions are at the same temperature, there is no net e.ni.f. But if

there is a difference in temperature between the junction the e.m.f. will beproduced.

v This e.m.f. will depend upon the two metals and the temperature between thejunctions. One junction is held at 0°C and the equation which is used to findout the e.m.f. is

Page 27: UNIT 2 Mechatronics

27

v

Fig. 2.39. Thermocouple

v There are three e.m.f.s present in a thermoelectric circuit. In this the Seebecke.m.f. is caused by the junction of dissimilar metals and the Pettier e.m.f. iscaused by a current flow in the circuit, and the Thomson e.m.f. which resultsfrom a temperature gradient in the materials.

v It is observed that all thermocouple circuits must involve at least twojunctions. In that one of the junctions senses the desired or unknowntemperature.

v This junction is called the hot or measuring junction. The other junction isusually maintained at a known fixed temperature and this junction is called thecold or reference junction.

v If the temperature of the reference or cold junction is known, the temperatureof the hot or the measuring junction can be calculated by using thethermoelectric properties of the materials.

v If thermocouple circuit can have other metals in the circuit and they will haveno effect on the thermoelectric e.m.f.

v A thermocouple can be used with the reference junction at a temperature otherthan

v 0°C.v For that we assume a 0°C junction and the correction has to be applied using

the law of intermediate temperatures.

The equation used in this is

Fig. 2.41. Las’ of intermediate temperature

Page 28: UNIT 2 Mechatronics

28

v Here to maintain the 0°C at one junction a compensation circuit is Used toprovide an e.m.f. which varies with the temperature of the cold junction.

v When it is added to the thermocouple e.m.f. it will generate a combined e.m.f.This is shown in Fig.2.42.

Fig. 2.42. Compensation thermocouple

v In the above Fig.2.42, the wires from the measuring junction are screweddirectly to an isothermal block terminal strip.

v The temperature of the block is ambient temperature.v This reference temperature is measured by semiconductor sensor and

compensation circuitry develops a voltage Ecomp which is combined withmeasuring junction and the net voltage across the voltmeter = T (Temperaturebeing measured).

v The isothermal block can accept many thermocouple pairs in multichannelinstruments with microprocessor computing power since the T (referencejunction sensor now sends its temperature data to the computer whichcomputes the needed voltage correction for each thermocouple.

v The thermocouples like E, J, K and T are relatively cheap and it has accuraciesof about ± ito 3%.

v The noble metal thermocouples are very high cost compared with this and ithas accuracies of about ±1% better than the base metal thermocouples.

v Thermocouples are used in applications ranging from measurement of roomair temperature to that of a liquid metal bath. The problems which may beencountered are1. Faulty reference junction,2. Installation faults,3. Junctions formed by users may involve excessive temperatures or faulty

soldering techniques,4. Gross errors can result due to wrong installation of thermocouple.

2. Resistance Temperature Detectors (RTDs)

v Resistance temperature detectors (RTDs) or resistance thermometers are basicinstruments for measurement of resistance.

v The materials used for RTDs are Nickel, Iron, Platinum, Copper, Lead,Tungsten, Mercury, Manganin, Silver, etc.

v The resistance of most metals increases over a limited temperature range andthe relationship between Resistance and Temperature is shown below.

Page 29: UNIT 2 Mechatronics

29

vFig. 2.43. Resistance temperature detector

v The Resistance temperature detectors are simple, and resistive elements in theform of coils of wire and it is shown in the above Fig.2.44.

v The equation which is used to find the linear relationship in RTD is

Fig. 2.44. RTD element

Constructional Details ofRTDs:v The platinum, nickel and copper in the form wire are the most commonly used

materials in the RTDs.v Thin film platinum elements are often made by depositing the metal on a

suitable substrate wire- wound elements involving a platinum wire held by ahigh temperature glass adhesive inside a ceramic tube.

v This is shown in Fig.2.45.

Fig. 2.45.

Page 30: UNIT 2 Mechatronics

30

Salient Features ofRTDs:1. High degree of accuracy.2. Resistance thermometer is interchangeable in a process without compensation orrecalibration.3. It is normally designed for fast response as well as accuracy to provide closecontrol of processes.

3. Thermistorsv Thermistor is a semiconductor device that has a negative temperature

coefficient of resistance in contrast to positive coefficient displayed by mostmetals.

v Thermistors are small pieces of material made from mixtures of metal oxides,such as Iron, cobalt, chromium, Nickel, and Manganese.

v The shape of the materials is in terms of discs, beads and rods.v The thermistor is an extremely sensitive device because its resistance changes

rapidly with temperature.v The resistance of conventional metal-oxide thermistors decreases in a very

non-linear manner with an increase in temperature is shown in the Fig.2.46below.

v The change in resistance per degree change in temperature is considerablylarger than that which occurs with metals.

Fig. 2.46. Thermistors

v The simple series circuit for measurement of temperature using a thermistorand the variation of resistance with temperature for a typical thermistor isshown in the below Fig.2.47.

Fig. 2.47. Thermistor

v The thermistor is an extremely sensitive device because its resistance changesrapidly with temperature.

v Thermistors have many advantages when compared with other temperaturesensors.

v The main disadvantage is highly non-linear behaviour.

Page 31: UNIT 2 Mechatronics

31

4. Thermodiodes and Transistors

(a) Thermodiodes:v Thermodiode is widely used method for measuring temperature. When the

temperature of doped semiconductors changes, the mobility of their chargecarriers changes and this affects the rate at which electrons and holes candiffuse across ap-n junction.

1. Measurement of temperature,2. Control of temperature,3. Temperature compensation,4. Measurement of thermal conductivity,5. Measurement of power at high frequencies,6. Measurement of composition of gases,7. Providing time delay,8. Vacuum measurements.

v The difference in voltage and current through the junction is a function of thetemperature. The equation which is used to find the I is

v From the above equation the voltage ‘ V’ is proportional to the temperature onKelvin scale and the potential difference measurement across a diode atconstant current is used to measure the temperature.

(b) Transistor:v In Thermo transistor the voltage across the junction between the base and the

emitter depends on the temperature.v A common method is use of two transistors with different collector current

and finding the difference in the base-emitter voltages between them, and thisdifference is the measure of temperature.

Fig. 2.48. Transistor

v The thermotransistors can be combined with circuit components on a singlechip to give a temperature sensor.

v This is shown in the above Fig.2.48.

Page 32: UNIT 2 Mechatronics

32

5. Bimetallic strips

Fig. 2.49. Bimetallic thermostat

v A Bimetallic thermostat consists of two different metal strips boundedtogether and they cannot move relative to each other.

v These metals have different coefficients of expansion and when thetemperature changes the composite strips bends into a curved strip, with thehigher coefficient metal on the outside of the curve.

v The basic principle in this is all metals try to change their physical dimensionsat different rates when subjected to same change in temperature.

v This deformation may be used as a temperature- controlled switch, as in thesimple thermostat.

v The Fig.2.49 shows the Bimetallic thermostat which was commonly used withdomestic heating systems.

7.0 LIGHT SENSORS1. Photodiodesv Diodes like photodiodes and semiconductor diodes are connected into a circuit

in reverse bias giving a very high resistance.v When light falls on the junction the resistance of the diode will drop and the

current in the circuit will rise.

Fig. 2.50.

v The Fig.2.51 shows the diode characteristics.

Page 33: UNIT 2 Mechatronics

33

v If the diode is sufficiently reverse biased, it will breakdown.v The current passing through the diode when forward biased only.v If an A.C. voltage is applied across a diode, it can be regarded as only

switching on when forward bias it and being off in the reverse direction.v The photodiodes have a very fast response to light and it can be used as a

variable resistance device controlled by the light incident on it.

2. Photo Transistors

The transistors are come in two forms 1. npn, 2. pnp.

Fig. 2.51.

v The main current flows in at the collector and out at the emitter in npntransistor.

v The main current flowing in at the emitter and out at the collector in pnptransistor.

v The phototransistors have a light sensitive collector-base p-n junction.v There is a very small collector to emitter current when there is no incident

light. Suppose the light is incident a base current is produced and it isproportional to the light intensity.

v So this will produce a collector current and it is used for measure of the lightintensity.

v The example for photo transistors is photo Darlington arrangement.

Fig. 2.52. Photo Darlington arrangement

3. The Photo Resistorv Its resistance depends on the intensity of light falling on it, and the resistance

will decrease linearly as the intensity increases.v The photoresistor like cadmium sulphide has most responsive to the light

having wavelengths of about 520 mm to 700 mm.4. Array of Light Sensorsv This will be used in small space like rooms to determine the variations of light

intensity across that space.e.g., Automatic camera

Page 34: UNIT 2 Mechatronics

34

8.0 SELECTION OF SENSORS

The factors to be considered while selecting sensors are

1. The nature of output required from the sensor.2. The nature of measurement required.3. The accuracy of the sensor.4. The cost of the sensor.5. The power requirement of the sensor.6. The speed response of the sensor.7. The linearity of the sensor.8. The Reliability and Maintainability of the sensor.9. Environmental conditions under which the measurement is to be made.10. Signal conditioning requirements.11. The nominal and range of values of the sensor.12. Suitable output signals from the measurement.

PART- A

1. What is the use of sensors and transducers?

2. Differentiate between Range and Span.3. Give the formula for finding the repeatability of a transducer.4. What is hysteresis error?5. What is the difference between ‘ Accuracy’ and ‘ Precision’ ?6. What is threshold?7. What is Dead time and Dead zone?

8. What is resolution?9. What is Rise time and Settling time?

10. What is meant by Hall effect?11. What are the velocity and motion sensors?

12. What is non-linearity error?13. Give the example for measuring force.

14. What are the fluid pressure sensors?15. What are the liquid flow measuring devices?

16. What are the two types diaphragms?17. What are the Temperature measuring devices?

18. Give the example for light sensors.19. What is the basic principle in thermocouples?

20. Give some materials used in thermocouples21. What is offset voltage of an operational amplifier

22. What is the equation for V of an integrator?23. What is a precision diode?

Page 35: UNIT 2 Mechatronics

35

24. What is a comparator?25. Name an application of a Schmitt trigger.

26. Why integrators are preferred over differentiators in analog computers?27. What is a voltage follower?

28. What is the advantage of CMOS Schmitt trigger?PART-B

1. Explain the terminologies used in transducers.2. What are all the displacement sensors? Explain each one briefly.

3. Explain the position sensors with neat figure.4. Define proximity and explain the proximity sensors.

5. What are all the velocity and Motion sensors?6. How the pressure is measured? Explain the pressure sensors neatly.

7. Explain the temperature measurement sensors.8. Explain the light sensors with neat figure.

9. What are all the points to be considered while selecting the sensors?10. Explain the signal processing.

11. Explain some applications of operational amplifier.12. Explain the operation of successive approximation ADC.

13. How do a dual slope ADC and single slope ADC differ?14. What is Flash ADC ? Discuss.

15. Explain the construction of R-DR ladder DAC.16. Discuss the various terms associated with ADC.