19
+ Quotation 92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range mm 1. 5 to 99 0. 75 - 300 Least Count 0. 1~ 1.5 to 60 / 0. 2~ 60 to 99 mm 0. 1 mm With Probe - 1 Probe Rs. 14500 19000 Make Microprocessor Mitech M & W M & W Insize Insize Insize Model TM-8810 160 UTG-2841 UTG - 3941 ISU – 200C ISU – 250C ISU-200D -P Range mm 1.5 ~ 200 0.75 - 300 1.0 – 300 1.0 – 200 - - - Least Count 0.1 0. 01 mm 0.01mm / 0.001 inch 0.01mm / 0.001 inch 0.1mm 0.01mm 0.01mm Rs. 9900 22550 18000 15000 ---------- 105665 41942 92 - 1 Ultrasonic Thickness Gauge Transducers – Insize Make Code Meas. Range Appl. Temp. Apps. Rs. ISU – P05 1.2 - 230mm <60’C General use ----- ISU – P02 3 - 300mm <60’C For casting steel ----- ISU – P07 0.8 - 80mm <60’C For thin material ----- ISU – HT5 3 - 200mm <300’C For high temp. ----- ISU – T08 0.8 – 300mm <60’C General use ----- ISU – T06 0.7 – 50mm <60’C For casting steel ----- ISU – T12 3 - 350mm <60’C For thin material ----- ISU – T13 3 – 100mm <350’C For high temp. ----- 92 – 2 Ultrasonic Thickness Gauge - Metrix+ D % Model Rs 1 1 to 200 mm Resolution 0.01 mm 17 % UTM 5 9600 2 0.9 to 350 mm Resolution 0.01 mm UTM 9 12500 3 0.9 to 400 mm Resolution 0.01 / 0.01 mm Seltable UTM 27 16000 4 3 – 30 mm Through Coating With Probe Selection optional UTM 18CT 40000 5 3 – 30 mm Through Coating Probe P 5EE UTM 18CT 4800 6 0.65 – 200 mm Thickness Probe NO 7 UTM 18CT 6000 7 1.0 – 600 mm Thickness Probe NO 5 UTM 18CT 4800 8 Spare Probe Standard For UTM 5 & UTM 9 3400 9 Spare Probe 6 mm For UTM 5 & UTM 9 4000 10 High Temperature Ceramic Probe 10000 11 PC Interface RS 232C + Softwere + USB Adaptor For UTM 5 & UTM 9 3500 12 PC Interface RS 232c + Softwere For UTM 18CT 6000 *** Warranty – 6 Months , Certificate - No, Discount – No PDF created with pdfFactory Pro trial version www.pdffactory.com

Transcript of ULTRASONIC THICKNESS GAUGE -...

Page 1: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

+

Quotation 92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range mm 1. 5 to 99 0. 75 - 300 Least Count 0. 1~ 1.5 to 60 / 0. 2~ 60 to 99 mm 0. 1 mm With Probe - 1 Probe Rs. 14500 19000

Make Microprocessor Mitech M & W M & W Insize Insize Insize Model TM-8810 160 UTG-2841 UTG - 3941 ISU – 200C ISU – 250C ISU-200D -P Range mm 1.5 ~ 200 0.75 - 300 1.0 – 300 1.0 – 200 - - - Least Count 0.1 0. 01 mm 0.01mm / 0.001 inch 0.01mm / 0.001 inch 0.1mm 0.01mm 0.01mm Rs. 9900 22550 18000 15000 ---------- 105665 41942

92 - 1 Ultrasonic Thickness Gauge Transducers – Insize Make Code Meas. Range Appl. Temp. Apps. Rs. ISU – P05 1.2 - 230mm <60’C General use ----- ISU – P02 3 - 300mm <60’C For casting steel ----- ISU – P07 0.8 - 80mm <60’C For thin material ----- ISU – HT5 3 - 200mm <300’C For high temp. ----- ISU – T08 0.8 – 300mm <60’C General use ----- ISU – T06 0.7 – 50mm <60’C For casting steel ----- ISU – T12 3 - 350mm <60’C For thin material ----- ISU – T13 3 – 100mm <350’C For high temp. ----- 92 – 2 Ultrasonic Thickness Gauge - Metrix+ D % Model Rs 1 1 to 200 mm Resolution 0.01 mm 17 % UTM 5 9600 2 0.9 to 350 mm Resolution 0.01 mm UTM 9 12500 3 0.9 to 400 mm Resolution 0.01 / 0.01 mm Seltable UTM 27 16000 4 3 – 30 mm Through Coating With Probe Selection optional UTM 18CT 40000 5 3 – 30 mm Through Coating Probe P 5EE UTM 18CT 4800 6 0.65 – 200 mm Thickness Probe NO 7 UTM 18CT 6000 7 1.0 – 600 mm Thickness Probe NO 5 UTM 18CT 4800 8 Spare Probe Standard For UTM 5 & UTM 9 3400 9 Spare Probe 6 mm For UTM 5 & UTM 9 4000 10 High Temperature Ceramic Probe 10000 11 PC Interface RS 232C + Softwere + USB Adaptor For UTM 5 & UTM 9 3500 12 PC Interface RS 232c + Softwere For UTM 18CT 6000 *** Warranty – 6 Months , Certificate - No, Discount – No

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 2: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

• TT 100 will measure fom 1.5 to 200 mm perfectly.

• No warranty on probe.

Terms & Conditions –

• Goods offered - Subject to Prior Sale • Price Validity: "15 Days from Date of Quotation"

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 3: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

• C.S.T 2% extra against form C. Otherwise 5% without form C For Out of Gujarat Sales only. • VAT 15% extra for Sales within Gujarat. Prices Ex-Godown Ahmedabad. • Payment against Proforma Invoice, Packing, Forwarding & Freight extra. • Bank Detail – Kotak Mahindra Bank Ltd. • Branch – Shivranjini • Bank IFSC Code - KKBK 0000 810 • Bank Account No. 08102 00000 2689 • Note - While making payment online do mention your Company's name. • TIN NO 24070901229 , CST No. 24570901229 • We are looking forward to your valued orders.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 4: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 5: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

ULTRASONIC THICKNESS GAUGE >>TT100/110/120/130/140

TT100 TT110 TT120 TT130 TT140 Features:

• Portable size and easy operation • Suitable for any metallic and non-metallic materials ultrasonic can go through • Self-compensating of nonlinearity function is supplied for correction of pickup nonlineasity • 10 measuring values can be recorded for TT100,TT110,TT130;100 measuring values can be recorded for

TT140 • optional 2.5MHz, 5MHz and 7MHz transducers are available • Clear 4-Digit LCD display with backlight • 5 pre-set sound velocities for repeating applications • mm / inch selectable • TT100,TT130 and TT140 are suitable for thickness testing of various materials with sound speed range

1000-9999m/s • TT110 and TT120 are easy-operation models with only two keys suitable for thickness testing of steel • TT120: high-temperature model • TT140:with backlight display and the memory reach up to 99

Technical Specification

TT100 TT110 TT120 TT130 TT140 Measuring range 0.75 – 300.00mm (steel)

Measuring range for steel pipes Min.3.0mm thickness ×Φ20 diameter

Diameter of transducer Φ10 (standard) Φ6 (optional) Φ12(option l)

Display resolution 0.1mm 0.01mm 0.1mm Calibration 4.0mm steel base p ate integrated Tolerance ±(1%H+0.1) mm (H means the thickness of tes e piece)

Measuring units mm/inch Sound velocity

range 1000-9999m/s 5900 m/ 1000-9999m/s 1000-9999m/s

Display 4-Digital LCD 4-Digital LCD with backlight

Surface temperature -10℃ to +60℃ -10℃ to +300℃ -10℃ to +60℃ -10℃ to +60℃ Battery in i ator Low battery voltage indicator

Power supply 2 Pcs. AA batteries 1.5V O eration time 250 hours

Dimensions 126mm×68mm×23mm 118mm×67mm×28mm Weight Approx.250 including batt ries 330g

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 6: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

Standard delivery

• Main unit • 5MHz transducer • 5MHz angle transducer (for TT100/110/130) • ZW5P high temperature transducer for TT120 • Integrated steel calibration plate 4.0mm • Batteries AA 1.5V • Couplant • TIME Certificate • Warranty card • Instruction manual

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 7: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

Model TM – 8810 – MANUAL

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 8: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 9: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 10: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

Feature: Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials. Transducer models are available for special application, including for coarse grain material and high temperature applications. Two-Point Calibration function. Two work modes: Single point mode and Scan mode. Coupling status indicator showing the coupling status. Optional software to process the memory data on the PC. Optional thermal mini-printer to print the measured data via RS232 port. Specification:

Display:4.5 digits LCD with EL backlight. Measuring Range:0.75~300mm (in Steel). Sound Velocity Range: 1000~9999 m/s. MT160: 0.1/0.01mm Accuracy: ±(0.5%Thickness+0.04)mm, depends on materials and conditions Units: Metric/Imperial unit selectable. Four measurements readings per second for single point measurement, and ten per second for Scan Mode. Memory for up to 20 files (up to 99 values for each file) of stored values. Power Source:Two “AA” size, 1.5 Volt alkaline batteries. 100 hours typical operating time (EL backlight off). Communication:RS232 serial port. Outline dimensions:150×74×32 mm. Weight:245g

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 11: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

Configuration: No Item Quantity Note

Standard Configuration

1 Main body 1 2 Transducer 1 Model: N05/90° 3 Couplant Bottle 1 4 Instrument Case 1 5 Alkaline battery 2 AA size 6 Operating Manual 1 7 Warranty Card 1 8

Optional Configuration

9 Transducer: N02 See Table3-1 10 Transducer: N07

11 Transducer: HT5 12 Mini thermal printer 1 13 Print cable 1 14 DataPro for Thickness Gauge 1 For use on the PC 15 Communication Cable 1

Appendix A: Transducer selection

Model

Freq MHZ

Diam mm

Measuring Range Lower limit Description

N02 2.5 14 3.0mm~300.0mm(In Steel) 40mm (in Gray Cast Iron HT200)

20 for thick, highly attenuating, or highly scattering materials

N05 5 10 1.2mm~230.0mm(In Steel) Φ20mm×3.0mm Normal

Measurement

N05/90° 5 10 1.2mm~230.0mm(In Steel) Φ20mm×3.0mm Normal

Measurement

N07 7 6 0.75mm~80.0mm (In Steel) Φ15mm×2.0mm

For thin pipe wall or small curvature pipe wall measurement

HT5 5 12 3~200mm (In Steel) 30 For high temperature (lower than 300℃) measurement.

Appendix B: Sound Velocity in different materials

Material Sound Velocity In/us m/s

Aluminum 0.250 6340-6400 Steel, common 0.233 5920 Steel, stainless 0.226 5740 Brass 0.173 4399 Copper 0.186 4720 Iron 0.233 5930 Cast Iron 0.173-0.229 4400-5820 Lead 0.094 2400 Nylon 0.105 2680 Silver 0.142 3607 Gold 0.128 3251

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 12: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

Zinc 0.164 4170 Titanium 0.236 5990 Tin 0.117 2960 Epoxy resin 0.100 2540 Ice 0.157 3988 Nickel 0.222 5639 Plexiglass 0.106 2692 Polystyrene 0.092 2337 Porcelain 0.230 5842 PVC 0.094 2388 Quartz glass 0.222 5639 Rubber, vulcanized 0.091 2311 Teflon 0.056 1422 Water 0.058 1473

M & W make

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 13: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 14: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

Insize Make

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 15: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 16: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 17: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 18: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 19: ULTRASONIC THICKNESS GAUGE - 3.imimg.com3.imimg.com/data3/KE/RS/MY-419417/ultrasonic-thickness-gauge.pdf92 Ultrasonic Thickness Gauge / D-meter Make Dipel Time Model B 2 TT100 Range

PDF created with pdfFactory Pro trial version www.pdffactory.com