Ultrasonic TestingUltrasonic TestingPart 2Part 2
![Page 2: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/2.jpg)
NameCopyright © 2004 WI Ltd
Ultrasonic Testing techniques
• Pulse Echo• Through Transmission• Transmission with Reflection
![Page 3: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/3.jpg)
NameCopyright © 2004 WI Ltd
Pulse Echo Technique
• Single probe sends and receives sound
• Gives an indication of defect depth and dimensions
• Not fail safe
![Page 4: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/4.jpg)
NameCopyright © 2004 WI Ltd
Defect Position
No indication from defect A (wrong orientation)
AB
B
![Page 5: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/5.jpg)
NameCopyright © 2004 WI Ltd
Through Transmission TechniqueTransmitting and Transmitting and receiving probes receiving probes on opposite sides on opposite sides of the specimenof the specimen
Tx Rx
Presence of defect Presence of defect indicated by indicated by reduction in reduction in transmission signaltransmission signal
No indication of No indication of defect locationdefect location
Fail safe method
![Page 6: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/6.jpg)
NameCopyright © 2004 WI Ltd
![Page 7: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/7.jpg)
NameCopyright © 2004 WI Ltd
Through Transmission Technique
Advantages• Less attenuation• No probe ringing• No dead zone• Orientation does not
matter
Disadvantages• Defect not located• Defect can’t be
identified• Vertical defects
don’t show• Must be automated• Need access to both
surfaces
![Page 8: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/8.jpg)
NameCopyright © 2004 WI Ltd
Transmission with ReflectionRT
Also known as:Also known as:
Tandem TechniqueTandem Technique or or
Pitch and Catch TechniquePitch and Catch Technique
![Page 9: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/9.jpg)
NameCopyright © 2004 WI Ltd
Ultrasonic Pulse • A short pulse of electricity is applied to a
piezo-electric crystal• The crystal begins to vibration increases
to maximum amplitude and then decays Maximum
10% of Maximum
Pulse length
![Page 10: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/10.jpg)
NameCopyright © 2004 WI Ltd
Pulse Length• The longer the pulse, the more
penetrating the sound
• The shorter the pulse the better the sensitivity and resolution
Short pulse, 1 or 2 cycles Long pulse 12 cycles
![Page 11: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/11.jpg)
NameCopyright © 2004 WI Ltd
Ideal Pulse Length
5 cycles for weld testing
![Page 12: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/12.jpg)
NameCopyright © 2004 WI Ltd
The Sound Beam
• Dead Zone• Near Zone or Fresnel Zone• Far Zone or Fraunhofer Zone
![Page 13: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/13.jpg)
NameCopyright © 2004 WI Ltd
The Sound Beam
NZ FZ
Distance
Intensity varies
Exponential Decay
Main Beam
![Page 14: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/14.jpg)
NameCopyright © 2004 WI Ltd
Main Lobe
Side Lobes
Near Zone
Main Beam
The main beam or the centre beam has the highest intensity of sound energy
Any reflector hit by the main beam will reflect the high amount of energy
The side lobes has multi minute main beams
Two identical defects may give different amplitudes of signals
![Page 15: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/15.jpg)
NameCopyright © 2004 WI Ltd
Sound BeamNear Zone• Thickness
measurement• Detection of defects• Sizing of large
defects only
Far Zone• Thickness
measurement• Defect detection• Sizing of all defects
Near zone length as small as possible
![Page 16: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/16.jpg)
NameCopyright © 2004 WI Ltd
Near Zone
VfD
fV
D
4Near Zone
4Near Zone
2
2
![Page 17: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/17.jpg)
NameCopyright © 2004 WI Ltd
Near Zone• What is the near zone length of a 5MHz
compression probe with a crystal diameter of 10mm in steel?
mm
VfD
1.21000,920,54000,000,5104
Near Zone
2
2
![Page 18: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/18.jpg)
NameCopyright © 2004 WI Ltd
Near Zone
• The bigger the diameter the bigger the near zone
• The higher the frequency the bigger the near zone
• The lower the velocity the bigger the near zone
Should large diameter crystal probes have a high or low frequency?
VfDD
4
4Near Zone
22
![Page 19: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/19.jpg)
NameCopyright © 2004 WI Ltd
1 M Hz 5 M Hz
1 M Hz5 M Hz
Which of the above probes has the longest Near Zone ?
![Page 20: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/20.jpg)
NameCopyright © 2004 WI Ltd
Near Zone
• The bigger the diameter the bigger the near zone
• The higher the frequency the bigger the near zone
• The lower the velocity the bigger the near zone
Should large diameter crystal probes have a high or low frequency?
VfDD
4
4Near Zone
22
![Page 21: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/21.jpg)
NameCopyright © 2004 WI Ltd
Beam Spread• In the far zone sound pulses spread out
as they move away from the crystal
DfKV
DKSine or
2
/2
![Page 22: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/22.jpg)
NameCopyright © 2004 WI Ltd
Beam Spread
DfKV
DKSine or
2
Edge,K=1.2220dB,K=1.08
6dB,K=0.56
Beam axis or Main Beam
![Page 23: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/23.jpg)
NameCopyright © 2004 WI Ltd
Beam Spread
• The bigger the diameter the smaller the beam spread
• The higher the frequency the smaller the beam spread
DfKV
DKSine or
2
Which has the larger beam spread, a compression or a shear wave probe?
![Page 24: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/24.jpg)
NameCopyright © 2004 WI Ltd
Beam Spread• What is the beam spread of a 10mm,5MHz
compression wave probe in steel?
o
DfKVSine
35.7 1278.0105000
592008.12
![Page 25: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/25.jpg)
NameCopyright © 2004 WI Ltd
1 M Hz 5 M Hz
1 M Hz5 M Hz
Which of the above probes has the Largest Beam Spread ?
![Page 26: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/26.jpg)
NameCopyright © 2004 WI Ltd
Beam Spread
• The bigger the diameter the smaller the beam spread
• The higher the frequency the smaller the beam spread
DfKV
DKSine or
2
Which has the larger beam spread, a compression or a shear wave probe?
![Page 27: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/27.jpg)
NameCopyright © 2004 WI Ltd
Testing close to side walls
![Page 28: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/28.jpg)
NameCopyright © 2004 WI Ltd
Sound at an Interface• Sound will be either transmitted across
or reflected back
Reflected
Transmitted
Interface How much is reflected and transmitted depends upon the relative acoustic impedance of the 2 materials
![Page 29: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/29.jpg)
NameCopyright © 2004 WI Ltd
The Phenomenon of Sound
REFLECTIONREFRACTION
DIFFRACTION
![Page 30: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/30.jpg)
NameCopyright © 2004 WI Ltd
The Phenomenon of Sound
REFLECTIONREFRACTION
DIFFRACTION
![Page 31: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/31.jpg)
NameCopyright © 2004 WI Ltd
Law of Reflection• Angle of Incidence = Angle of Reflection
60o 60o
![Page 32: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/32.jpg)
NameCopyright © 2004 WI Ltd
Inclined incidence(not at 90o )Incident
Transmitted
The sound is refracted due to differences in sound velocity in the 2 DIFFERENT materials
![Page 33: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/33.jpg)
NameCopyright © 2004 WI Ltd
REFRACTION• Only occurs when:The incident angle is other than 0°
Water
Steel
Steel
Steel
Water
Steel
30°
Refracted
![Page 34: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/34.jpg)
NameCopyright © 2004 WI Ltd
REFRACTION• Only occurs when:The incident angle is other than 0°
Steel
Steel
Water
Steel
30°
Refracted
The Two Materials has different VELOCITIES
No Refraction
30°
30°
65°
![Page 35: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/35.jpg)
NameCopyright © 2004 WI Ltd
Snell’s Law
I
R
Material 1
Material 2
2 Materialin 1 Material
VelinVel
RSineISine
Incident
Refracted
Normal
![Page 36: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/36.jpg)
NameCopyright © 2004 WI Ltd
Snell’s Law
C
Perspex
Steel
C
20
48.3
2 Materialin 1 Material
VelinVel
RSineISine
59602730
48.3 20
SineSine
4580.04580.0
![Page 37: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/37.jpg)
NameCopyright © 2004 WI Ltd
Snell’s Law
C
Perspex
Steel
C
15
34.4
2 Materialin 1 Material
VelinVel
RSineISine
59602730
R 15
SineSine
2730596015SinSinR
565.0SinR4.34R
![Page 38: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/38.jpg)
NameCopyright © 2004 WI Ltd
Snell’s LawC
Perspex
Steel
C
20
S
48.3
24
![Page 39: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/39.jpg)
NameCopyright © 2004 WI Ltd
Snell’s Law
Perspex
Steel
S
CC
CCS
When an incident beam of sound approaches an interface of two different materials:REFRACTION occurs
There may be more than one waveform transmitted into the second material, example: Compression and Shear
When a waveform changes into another waveform: MODE CHANGE
![Page 40: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/40.jpg)
NameCopyright © 2004 WI Ltd
Snell’s Law
Perspex
Steel
C
CS
CS
C
S
If the angle of Incident is increased the angle of refraction also increases
Up to a point where the Compression Wave is at 90° from the Normal
90° This happens at the
FIRST CRITICAL ANGLE
![Page 41: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/41.jpg)
NameCopyright © 2004 WI Ltd
1st Critical Angle
C
27.4
S
33
C Compression wave refracted at 90 degrees
![Page 42: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/42.jpg)
NameCopyright © 2004 WI Ltd
2nd Critical Angle
C
S (Surface Wave)90
C
Shear wave refracted at 90 degrees
57
Shear wave becomes a surface wave
![Page 43: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/43.jpg)
NameCopyright © 2004 WI Ltd
1st Critical Angle Calculation
C
Perspex
SteelC
59602730
90 I
SineSine
59602730
SinI
458.0SinI
26.27I
S
190 Sin
27.2
![Page 44: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/44.jpg)
NameCopyright © 2004 WI Ltd
2nd Critical Angle Calculation
C
Perspex
Steel
C
32402730
90 I
SineSine
32402730
SinI
8425.0SinI
4.57I
S190 Sin
57.4
![Page 45: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/45.jpg)
NameCopyright © 2004 WI Ltd
1st.
2nd.
33°
90°
Before the 1st. Critical Angle: There are both Compression and Shear wave in the second material
S C
At the FIRST CRITICAL ANGLE Compression wave refracted at 90°
Shear wave at 33 degrees in the material
Between the 1st. And 2nd. Critical Angle: Only SHEAR wave in the material. Compression is reflected out of the material.
C
At the 2nd. Critical Angle: Shear is refracted to 90° and become SURFACE wave
Beyond the 2nd. Critical Angle: All waves are reflected out of the material. NO wave in the material.
![Page 46: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/46.jpg)
NameCopyright © 2004 WI Ltd
![Page 47: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/47.jpg)
NameCopyright © 2004 WI Ltd
Summary• Standard angle probes between 1st and
2nd critical angles (45,60,70)• Stated angle is refracted angle in steel• No angle probe under 35, and more
than 80: to avoid being 2 waves in the same material.
C
S
C S
One Defect Two Echoes
![Page 48: Ultrasonic testing for lvl 1 & 2 vol.2](https://reader035.fdocuments.net/reader035/viewer/2022081421/577c7ea91a28abe054a20c6e/html5/thumbnails/48.jpg)
NameCopyright © 2004 WI Ltd
Snell’s Law• Calculate the 1st critical angle for a
perspex/copper interface• V Comp perspex : 2730m/sec• V Comp copper : 4700m/sec
5.355808.047002730
SinI