Ultra Slim DC Power Supplies
www.matsusada-us.com
Sharp VersatileSharp VersatileSharp Versatile
RK-80 series
Ultra Slim DC Power Supplies
Power factor correction and
universal input
New user-friendly functions
Compact and light weight space
saving design
With low noise switching method
ideal for research purpose
Various operations by connecting multiple power supplies, such as master/slave, is possible.
For wider output rangeRK-80L:16V/10ARK-80:36V/5A
RK-80M:110V/1.3ARK-80H:320V/0.5A
4 different models with various
output voltages
80L
80M 80H
80
RK-80 series
1.38"(35mm)
4.88"(124mm)
RK-80
36V/2.2A
16V/5A
No.1
No.2
No.3
Quick access to the function needed
Ultra Slim DC Power SuppliesNEW
New and useful functions and stylish front panel design!
Useful new feature of variable setting range
Set voltage/current value within 80W, then turn on output *Not automatic range change which can output 80W all the time. Resetting is required.
10.63"(270mm)10.63"(270mm)
RK-80 series is DC regulated power supply which has two time wider output setting range. For example standard
80W 36V model is enable to set up to 2.2A current (80W 36V), but RK-80 is enable to set maximum 5A, and has
both setting range of 36V/2.2A and 16V/5A.
Further more, the size 1/3, and weight is 1/5 of standard 80W power supply. Featuring OVP, OCP, 3 individual
presets and locking function, RK-80 is high cost performance model.
02
Preset setting is automatically displayed when output is off.
OCP is added for more safety operation.
Quick lock with one touch action.Two selectable lock options.
03
9
Function to memorize 3 different voltage and current settings in addition to standard preset function.No need to adjust the output when different setting, and convenient function for production inspection process or testing which require frequent data taking.
Lock all the function other than reset lock mode, and effective for purpose to avoid mis-operation when controlled.
Function to output ON/OFF of total 32 units from one master unit. (when master/slave)
It is possible to delay the ON/OFF time, and simultaneous ON/OFF setting is possible as well.
Ideal function for application which require time delay for ON/OFF setting.
Full LOCK Normal LOCK
Lock voltage and current setting dial, and effective for purpose to avoid changing output setting by mistake or when easy emergency stop is required.
3
12
Function to select two different lock functions for two different purpose."Full Lock" locks all the function on front panel, and "Normal Lock" locks all the function except for ON/OFF. "Full Lock" mode shall be good in case mis-operation have to be completely avoided, and
"Normal Lock" mode shall be good in case to avoid mis-operation but secure the way for emergency stop of power supply. You can select the best mode according to your level of "Security", (in both modes, emergency stop is possible with Power Switch.)
* When 115VAC Maximum Output
Press down SETSelect a memorywith 3 buttons
Set voltage andcurrent
OUTPUT ON(From Master)
OUTPUT OFF(From Master)
Up to 32 units
Master
Slave1
Slave2
Slave3
t1 t5
t2 t6
t3 t7
t4 t8
*setting range of t1 to t8 is 0.0s to 99.9s
LINEUP
MULTI SETTING FUNCTION
TWO MODE LOCK FUNCTION
DELAY TRIGGER FUNCTION
Memory a
Memory b
Memory c
MODELOutput voltage(V)
Output current(A)
Output Power(W)
Ripple
(mVrms) (mArms)Temperature coefficient(ppm/°C)
CV CC
±200
0 to 10 RK-80L 5 100 to 16
0 to 5 RK-80 5 50 to 36
0 to 1.3 RK-80M80
10 20 to 110
0 to 0.5 RK-80H 20 10 to 320
±10085 to 264VAC50/60Hz 1Ø 0.9kg1A 0.5A 99%
*
Input Voltage Input Current (typ) Power factor (typ)Weight(typ)
AC Input
*
*Master/Slave function is available on the model with -LGmb option.
AC in115V
AC in230V
04
+S
-S
R
VO IO
Load- +
VL
Compensate the voltage drop (V0-VL) due to resistance of output lead or drop of stability by contact resistance. (maximum 0.5V)
*+S is common. So external control voltage shall be input with +S as reference. Otherwise it can cause failure.
5V
or VCE
REMOTE FUNCTIONS
FUNCTIONS
Remote sensing
Remote switch ON/OFF
Sink current 1mA
Output
ON
OFF
Open collector
VCE 0.4V
VCE 2V
Relay
SHORT
OPEN
+S(common)*
4.88
"(12
4)0.
31"(
8)
OUTPUTOCP
LOCK
SET
OVP/
VCC
A
CV
10.63"(270)0.89"(22.7) 0.16"(4)
1.38"(35)
AC 100V-240V 50/60HzINPUT
-S
--
LS+LS-+S
++
DIMENSIONS inch (mm)
side
front back
Rear panelFront panel
12
6
1
2
3
4
5
13
14
9
7
15
1617
18
19
8
10
11
Output voltage and OVP setting display
Output current and OCP setting display
Remote programming display
Output display
Light up when output voltage/current control in remote mode.
Light up when output is on.
To be used to turn output on/off when local mode as well resetting protection functions.
This has priority over all operations for safety reason.
1
2
Monitor terminal
Constant voltage operation mode display
Constant current operation mode display
PRESET switch
OVP/OCP switch
LOCK switch
OUTPUT voltage·OVP setting dial
OUTPUT current·OCP setting dial
Power ON/OFF switch
LS switch(remote switch)
+Sense
OUTPUT terminal
-Sense
AC inlet
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
3
4
OUTPUT ON/OFF switch
05
Output Control
Output Function
Lock Function
Output Display
Protection
Other Functions
CV Mode : By rotary encoder on front panel Setting resolution of output voltage is 1/256 of rated maximum voltage
CC Mode : By rotary encoder on front panel Output current setting accuracy is 1/256 of rated maximum output current. Remote control is option. See OPTION for remote control function.
Wide output range, automatic limit setting at 80W for voltage and current In CV mode output current drop down when output power is more than 84.05W In CC mode output voltage drop down when output power is more than 84.05W
Lock function locks the output voltage and current setting
Voltage : 3-digit digital meter. *Accuracy is ±0.5% FS ±2 digitsCurrent : 3-digit digital meter. *Accuracy is ±0.5% FS ±2 digits(*Accuracy of preset setting is ±1% FS ±2 digits)
Over voltage protection (OVP) : Cut off the output at set value Setting range : appx. 5% to110% of rated maximum voltage Setting : By front panel rotary encoder Reset : By output ON/OFF switch or remote switch (manual control)Over current protection (OCP) : Cut off the output at set value Setting range : appx. 5% to110% of rated maximum current Setting : By front panel rotary encoder Reset : By output ON/OFF switch or remote switch (manual control)Over temperature protection. (OTP) : Cut off output at abnormal inside temperature.Reset(after temperature get down to normal temperature) : Output ON/OFF switch or Remote switch (manual control)Input brownout(ACF).Blackout protection Output is cut off when input voltage decreased. Reset (when normal voltage value or recovery from blackout) Manual recovery by OUTPUT switch or remote switch for blackout protection(re-output protection function). Automatic recovery when blackout protection is canceled.Sense reverse connection
Remote switch ON/OFF (TTL or external relay), Remote sensingDelay trigger: Individual setting of ON delay and OFF delay(0.0 to 99.9sec)Multi setting function: Voltage and current memory "a", "b" and "c" setting in addition to standard voltage and current preset
Operation Temp
Storage Temp
Storage humidity
Isolation voltage
0°C to 40°C
-40°C to +85°C
20% to 80% (non-condensing)
±250V-DC (Positive or Negative terminal grounding)
SPECIFICATION
Split operation
SERIES OPERATION · PARALLEL OPERATION
Vout+-
+-
V1+V2
PS1
V1
PS2
V20V
[caution] Total output voltage is to be up to 250V. Therefore for models with output voltage of over 250V, series operation cannot be conducted. Output current is to be the smallest current of those.
Please keep all the settings of voltage the same. Output current will be the summation of each current.[caution] Please keep OVP level of power supply maximum to prevent any damage.
[caution] In case of +- operation, the remote connector is connected to negative output terminal. So never connect other remote control to the connector.
PS1
PS2
+Vout
-Vout
0V
+-
+-
Series operation
+
-
PS1
PS2
+-
+-
Load
Parallel operation
RK-80 power supply of same model number can be connected in series or parallel to increase output voltage or current.
ACCESSORIES·Input AC cable 2.5m single phase 3pin type(1)·Instruction manual(1)·Ground plate(1)
Ground plate
*For safer operation connect ground plate and output terminal.
06
GPIB
USB
Dsub
32 units can beconnected to one CO-G32m.
CO-MET2-9
CO-G32m
RK-80
RK-80
A
A
A
A
A
A
A
Master
Slave
Up to 32
-LUs1 :USB Interface Board *1 *2
Enable digital control via USB
Modular jack
Converter
RS-232CRS-485
CO-MET2-25
CO-MET4-25
OPTION
-LGmb :Digital Interface Board *1 *2
Enable digital control via GPIB/ RS-232C/ RS-485 as well asone control with Master/Slave function.
-LRmf :Remote multi function *1
+CV, CCor*4
One control function *3
via Master/Slave
Output control
Vout . Iout
0 to MAX
R
0 to about 10k
Vcon . Icon
0 to about 10V
When controlling several RK-80 power supplies via USB, a USB hub will be required between the PC and RK-80 power supplies. GPIB enables
control of up to 14 CO-G32m modules.
+S(common)
Add above L mark to the model number when ordering {e.g} RK-80-LGmb alphabetical order
*-LGmb, -LRmf, -LUs1 cannot be ordered together.
*1) Either -LGmb, -LUs1, -LRmf can be selected.
*2) For detailed specification of USB and digital interface, please refer date sheet of CO series.
*3) Delay triger Function when master/slave can be set individually . It is also possible to cancel one control function except for output by changing Remote/Local, and set voltage and current preset for each unit.
*4) +S is common. So external control voltage shall be input with +S as reference. Otherwise it can cause failure.
*5) Previous model is Metal RS-232C module.
*6) Previous model is Metal RS-485 module.
CO-M cableOne 2 meter cable is provided per unit. Please notify your sales representative if you need a longer cable or additional cables.
Remote control, it operates 3 range switchable mode as follows.
RK-80L
RK-80
RK-80M
RK-80H
High 16V
10V
8V
36V
27V
16V
110V
80V
60V
320V
250V
160V
5A
8A
10A
2.2A
3A
5A
0.7A
1A
1.3A
200mA
300mA
500mA
Middle
Low
High
Middle
Low
High
Middle
Low
High
Middle
Low
model Switch number Range Rated output voltage Rated output current
1
2
3
1
2
3
1
2
3
1
2
3
*5
*6
07
AC INPUT CABLE
CABLE TYPE 1CABLE TYPE 3
125V / 10A 250V / 10A
CABLE TYPE 4(standard)
250V / 10A
♦Book stand
♦Binder
♦Rack mount holder
For one unit operation...
For the applications which require 2 to 6 units combination. Dual, triple and quad multiple operation is possible.
*Cooling fan is needed for more than 3 units combination.
Various accessories are available for convenient use of the unit.
RK-80 series Accessory Kit
*Power supply is not included in the accessories.
10 Units/1 rack holder, and can be placed in a cabinet. Easy to take one unit out.Best suitable for a system operation.With fan unit.
1117-01A
Customer Inquiry Sheet (RK-80 series)Please copy this page and fax to above fax number after filling out form below.
USA/canada : 1-888-652-8651other countries : 1-81-75-229-6366FAX
2570 N.First Street Suite 200 San Jose, CA 9513180 Orville Drive Suite 100 Bohemia, NY 11716 5430 LBJ Freeway, Suite 1200 Dallas, TX 75240 Kyoto-City, Kyoto Japan
Tel: +1-408-273-4573 Fax: +1-408-273-4673Tel: +1-631-244-1407 Fax: +1-631-244-1496Tel: +1-972-663-9336 Fax: +1-972-663-9337Tel: +81-75-229-6355 Fax: +81-75-229-6366
San Jose Office : New York Office :Dal las Of f ice : International Office :
www.matsusada.com/contactwww.matsusada.com/productFor products For contact
Headquarters : 745 Aoji-cho Kusatsu Shiga 525-0041 Japan Tel: +81-77-561-2111 Fax: +81-77-561-2113
<option>
-LGmb (GPIB,RS-232C,RS-485) -LUs1(USB I/F)
What product are you interested in?
a quotation
RK-80 RK-80M RK-80HRK-80L