Ultra Fast Speed High Reliability User-Friendly€¦ · Ultra Fast Speed Fusion of Ultra Fast MRM...

2
Ultra Fast Speed Fusion of Ultra Fast MRM and Ultra Fast Polarity Switching An Ultra Fast Scan Speed of 15,000 u/sec 500 MRMs per Second, the Most Ever Possible High Reliability Robust System Provides Long-term Data Stability UFsweeper TM Technology Dramatically Minimizes Cross Talk Excellent Linearity with Wide Dynamic Range User-Friendly Easy Maintenance for Minimized Instrument Downtime Single-vendor Solution Provides Seamless Operation Quantitation Browser for Effective Multi-analyte Quantitation

Transcript of Ultra Fast Speed High Reliability User-Friendly€¦ · Ultra Fast Speed Fusion of Ultra Fast MRM...

Page 1: Ultra Fast Speed High Reliability User-Friendly€¦ · Ultra Fast Speed Fusion of Ultra Fast MRM and Ultra Fast Polarity Switching An Ultra Fast Scan Speed of 15,000 u/sec 500 MRMs

Ultra Fast Speed

Fusion of Ultra Fast MRM and Ultra Fast Polarity SwitchingAn Ultra Fast Scan Speed of 15,000 u/sec500 MRMs per Second, the Most Ever Possible

High Reliability

Robust System Provides Long-term Data StabilityUFsweeperTM Technology Dramatically Minimizes Cross TalkExcellent Linearity with Wide Dynamic Range

User-Friendly

Easy Maintenance for Minimized Instrument DowntimeSingle-vendor Solution Provides Seamless OperationQuantitation Browser for Effective Multi-analyte Quantitation

Page 2: Ultra Fast Speed High Reliability User-Friendly€¦ · Ultra Fast Speed Fusion of Ultra Fast MRM and Ultra Fast Polarity Switching An Ultra Fast Scan Speed of 15,000 u/sec 500 MRMs

Unit-205385>107Vitamin D3Unit-155431>165Vitamin EUnit-205473>207Vitamin E acetate

Unit-355397>69Vitamin D2

Unit-305451>187Vitamin K1Unit-255269>93Vitamin A palmitate

Unit-255269>93Vitamin A

MS2 resolution

CE (eV)

Dwell time(ms)TransitionTransition

MRM Mode Parameters

100100--50000ppb50000ppb

This document describes simultaneous analyses of 7 fat soluble vitamins and derivatives by ESI negative mode. Excellent linearity (R2=0.99 or better) was obtained in each analysis.

5tablets↓

Add 25mL n-hexane and mix for 30 seconds then heat (60℃, 45min) ↓

Mix for 30 seconds,Centrifuge(3,000rpm, 10min) ↓

Filter supernatant (0.2um)

Sample Preparation 10x Sample Dilution

1000x Sample Dilution

10xSample Dilution

10x Sample Dilution

Vitamin D2 Vitamin EVitamin E

acetate Vitamin K1

20.75ppb(%RSD 8.60)

1191ppb(%RSD 2.04)

8913ppb(%RSD 1.46)

2379ppb(%RSD 4.48)

103.8 ng103.8 ng 11.9011.90μμgg 44.5744.57μμgg 5.9555.955μμgg

: Shim-pack XR-ODSⅡ (2.0 mmI.D. x 75 mmL., 2.2 μm): Methanol: Ethanol: 0 %B (0 -4min) - 50 %B (6-7 min) - 30 %B (7.01 - 10 min): 0.5 mL / min: 1μL: 40 ℃: 1.5 L / min: 10 L / min: 250℃: 400℃

Column Mobile phase AMobile phase BGradient programFlow rateInjection volumeColumn temperatureNebulizing gas flowDrying gas flowDL temperatureBH temperature

Table 2 Analytical Conditions

Vitamin A

0.0

2.5

(x1,000,000)

Vitamin D2

1.0

2.0

(x1,000,000)

0.0

Vitamin E

0.0

1.0

2.0

3.0

(x1,000,000)

Vitamin K1

0.0

2.5

5.0(x1,000,000)

Vitamin A palmitate

0.0 1.0 2.0 3.0 4.0 5.0 6.0 min

0.5

1.0

(x100,000)

0.0

Vitamin Eacetate

0.5

1.0

(x10,000,000)

0.0

Vitamin D3

1.0

2.0

(x1,000,000)

0.0

55--1000ppb1000ppb

0 250 500 750 Con.0.00

0.50

1.00

1.50Area(x100,000)

55--1000ppb1000ppb

0 250 500 750 Con.0.00

0.25

0.50

0.75

1.00

Area (x100,000)

Area (x100,000)

55--1000ppb1000ppb

0 250 500 750 Con.0.0

0.5

1.0

0 20000 40000 Con.

500500--50000ppb50000ppb

0.0

0.5

1.0Area (x10,000,000)

0 250 500 750 Con.

55--1000ppb1000ppb

0.0

2.0

4.0

6.0

8.0

Area (x100,000)

0 20000 40000 Con.0.0

2.0

4.0

6.0

Area (x100,000)

100100--50000ppb50000ppb

0 20000 40000 Con.0.0

1.0

2.0

3.0

Area (x100,000)

(x100)

1.25 1.50

0.0

2.0

4.0

6.0

8.0

397.40>69.15(+)

1.34

4

1.50 1.75

0.0

0.5

1.0

(x100,000)431.40>165.10(+)

1.67

9

2.25 2.46

0.0

0.5

1.0

1.5

(x1,000,000)473.40>207.05(+)

2.27

2

3.00 3.25

0.0

1.0

2.0

(x1,000)451.40>187.25(+)

3.06

8