UL924 PHOTOLUMINESCENT EXIT SIGN FL - evacmap.comUL924 PHOTOLUMINESCENT EXIT SIGN ULC SIDE VIEW...
Transcript of UL924 PHOTOLUMINESCENT EXIT SIGN FL - evacmap.comUL924 PHOTOLUMINESCENT EXIT SIGN ULC SIDE VIEW...
FLSurface Mount Design
UL924 PHOTOLUMINESCENT EXIT SIGN
ULC
SIDE VIEW FRONT VIEW
DIRECTIONAL INDICATOR
7 17/20" (200 mm)
2.5"(65 mm)
Install directly adjacent to the ExitSign, same arrow can be used for both directions. Attached by screws.
U01A3120
1/50"(0.5 mm)
* Directional Indicators are ordered separately for FL model. Universal design allows them to be used for either LEFT, RIGHT, or BOTH DIRECTIONS.ORDERING INFORMATION
1. EXIT SIGN 2. DIRECTIONAL INDICATOR
FL - FLUSH
FAMILY
RD - REDGN - GREEN
FL
PRODUCT CODE SECOND COLOR
* First Color = Luminous
FL - FLUSHC02AR - for UC02A3120
FAMILY
RD - REDGN - GREEN
EXAMPLE :
FL
PRODUCT CODE SECOND COLOR
CO2AR FL RD
* First Color = LuminousUC02A3120- Luminous Face
UC02A3120 FL RD
UC02A3120 FL GN
UL Listed (standard) meets and exceeds the observation visibility criteria required for UL-924 "Emergency Lighting and Power Equipment"meets NFPA Life Safety Code 101 requirements.ULC Listed to ULC/ORD-924-02 for Canada
LISTING
WARRANTY
5 foot-candles of fluorescent illumination must be present on the sign faceat all times during building occupancy. With exposure to this light source for60 minutes the sign will be legible in total darkness to observers standing 75 feetaway from the sign, for least 90 minutes after all light has been extinguished
CHARGING LIGHT SOURCE LEGIBLE VIEWING DISTANCE: 75 feet
5 years Manufacturer's Limited Warranty against material defect andworkmanship. PRODUCT CARE : Periodically clean the sign facing with a damp cloth, and conduct periodic inspections to ensure the sign is clear and visible.
INTENDED USE
CONSTRUCTIONMade of High-Quality Aluminum sheeting. The All-Aluminum box housing is impact-resistant, water-proof, corrosion-proof, and flame-retardant. The High-Brightness photoluminescent material is applied directly onto the aluminum box without the use of resin or plastic. It is non-radioactive, non-toxic, flame-retardant, high temperature resistant. Proprietary technology provides uniform illumination across the sign.
INSTALLATIONUniversal (Top and End/Edge) bracket mounting, Housing secures to the mounting bracket with 4 screws. Surface mounting with 4 screws.Install photoluminescent EXIT signs only in locations, where an externalillumination source is present, is deemed reliable and is supplied by a circuit not controlled by automatic timers or sensors and whose controls are accessible only to authorized personnel. This reliable externalillumination source is to be energized at all times during building occupancy.
Ideal for building code and supplementary applications, including those requiring attractive, quick installation exit signs. Perfect in areas where electrical wiring is difficult, unavailable or not suitable.NO WIRING, NO ELECTRICITY, and NON-RADIOACTIVE.
OPERATIONAL LIFE EXPECTANCY: 20 YEARS +Product longevity depends on maintaining the original integrity of the product.
12.2"
7 17/20"
1/50"
U01A3120
(200 mm)
(0.5 mm)
(310 mm)
7 17/20" (200 mm)
DIMENSIONS
U01A3120
EXAMPLE : UC01A3120 FL RDUC02A3120 FL RD
UC01A3120 FL RD
Toll Free: 1-800-504-3822 Tel: (514) 369-2444 Fax: (514) 313-5563 [email protected] WWW..EVACMAP.COMUSA: 555 West Fifth Street, 31st Floor, Los Angeles, CA 90013 Canada:16 Westminster Ave. N., Suite 201, Montreal, QC H4X 1Z1
Catalog Number: UC01A3120-FL (RED) Catalog Number: UC02A3120-FL (RED / GREEN)
Catalog Number: UC04A3720-FL2 - (Red or Green)
(call for volume or wholesale prices)
FL2Surface Mount Design
UL924 PHOTOLUMINESCENT EXIT SIGN
14.5"
7 17/20"
1/50"
(200 mm)
(0.5 mm)
(370 mm)
7 17/20" (200 mm)
DIMENSIONS
SIDE FRONT
EXAMPLE : UC04-FL2-RDUC04-FL2-GN
FL2 -Flat Panel Model
FAMILY
RD - REDGN - GREEN
FL2
PRODUCT CODE FACE COLOR
* First Color = Luminous
UC04 - EXIT Luminous
GREEN
ULCPHOTOLUMINESCENT EXIT SIGN FWBX ( UL 924 )
Includes two adjustable Directional Indicators
UC04 SERIESRED or GREEN Face Finish with Luminous EXIT letters
RED
ORDERING INFORMATION
UL Listed (standard) meets and exceeds the observation visibility criteria required for UL-924 "Emergency Lighting and Power Equipment"meets NFPA Life Safety Code 101 requirements.ULC Listed to ULC/ORD-924-02 for Canada
LISTING
WARRANTY
5 foot-candles of fluorescent illumination must be present on the sign faceat all times during building occupancy. With exposure to this light source for60 minutes the sign will be legible in total darkness to observers standing 50 feetaway from the sign, for least 90 minutes after all light has been extinguished
CHARGING LIGHT SOURCE LEGIBLE VIEWING DISTANCE: 50 feet
5 years Manufacturer's Limited Warranty against material defect andworkmanship. PRODUCT CARE : Periodically clean the sign facing with a damp cloth, and conduct periodic inspections to ensure the sign is clear and visible.
INTENDED USE
CONSTRUCTIONMade of High-Quality Aluminum sheeting. The All-Aluminum box housing is impact-resistant, water-proof, corrosion-proof, and flame-retardant. The High-Brightness photoluminescent material is applied directly onto the aluminum box without the use of resin or plastic. It is non-radioactive, non-toxic, flame-retardant, high temperature resistant. Proprietary technology provides uniform illumination across the sign.
INSTALLATIONUniversal (Top and End/Edge) bracket mounting, Housing secures to the mounting bracket with 4 screws. Surface mounting with 4 screws.Install photoluminescent EXIT signs only in locations, where an externalillumination source is present, is deemed reliable and is supplied by a circuit not controlled by automatic timers or sensors and whose controls are accessible only to authorized personnel. This reliable externalillumination source is to be energized at all times during building occupancy.
Ideal for building code and supplementary applications, including those requiring attractive, quick installation exit signs. Perfect in areas where electrical wiring is difficult, unavailable or not suitable.NO WIRING, NO ELECTRICITY, and NON-RADIOACTIVE.
OPERATIONAL LIFE EXPECTANCY: 20 YEARS +Product longevity depends on maintaining the original integrity of the product.
Toll Free: 1-800-504-3822 Tel: (514) 369-2444 Fax: (514) 313-5563 [email protected] WWW..EVACMAP.COMUSA: 555 West Fifth Street, 31st Floor, Los Angeles, CA 90013 Canada:16 Westminster Ave. N., Suite 201, Montreal, QC H4X 1Z1