UK PERKINS APS P1250 kVA - · PDF fileUK PERKINS APS P1250 kVA GENERATOR FEATURES ENGINE DATA...

1
UK PERKINS APS P1250 kVA GENERATOR FEATURES ENGINE DATA ALTERNATOR DATA Manufacturer/Model Cylinder Arrangement Displacement Bore And Stroke Compression Ratio Rated Rpm Gross Bhp @ Prime Power Gross Bhp @ S.By Power Governor Type UK Perkins, 4012-46TWG2A 0 12- 60 V 45.842 Litres 160 x 190 mm 13.6 : 1 1500 1492 1641 Manufacturer Number of Phase Power factor Number of pole Insulation Temperature Rise Total Harmonics (TGH/THC) Exciter Type Number Of Bearing Leroy somer EU 3 0.8 4 Class H Class F < 2% (AT NO LOAD) Shunt One POWER FEATURES Prime Power – 400/230V @ 50 Hz:1002 kW / 1253 kVA Stand by Power- 400/230V @ 50 Hz: 1108 kW / 1385 kVA Ÿ Engine (UK Perkins 4012-46TWG2A) Ÿ 24v Charge alternator Ÿ Governor: Mechanical Ÿ Alternator (Mecc alte UK / Leroy somer TAL) Ÿ Single bearing alternator IP 23,insulation class H Ÿ Radiator 50° C (122 F) Ÿ Skid and vibration isolators Ÿ Dry type air filter Ÿ Main line circuit breaker Ÿ 24v Battery , Rack and Cable Ÿ Industrial silencer Ÿ User manual OPTIONAL ITEMS Engine & Radiator Ÿ Heat shield protection exhaust Ÿ Oil drain extension Ÿ Lube oil drain pump Ÿ Stone Protection guard Ÿ Battery charger Ÿ Engine Block heater Ÿ Battery Isolator Fuel System Ÿ 12 or 24 Hours day tank Ÿ Bulk fuel tank connections Ÿ Fuel / Water separator filter (Racor) Alternator Ÿ Anti-Condensation Heater Ÿ Alternator Dust Filters Ÿ PMG excitation Ÿ Single phase Exhaust Ÿ Residential, Critical Silencer Ÿ Flexible exhaust connection Enclosure Ÿ EM-1,5 Ÿ 85 dBA @ 1m Ÿ Dimension mm (L x W x H) – 12192 x 2438 x 2895 Control Panel Ÿ Deep sea Electronics * For more technical information, please refer to the website below. RPP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. A 10% overload capability is available for a period of 1 hour within 12hour period of operation, in accordance with ISO 3046-1. ESP: The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed Picture shown above is only for illustration purpose, May contain optional item. In Line with Our Policy of Continuous Development, We reserve The Right to Change Specification without Notice Electronic www.apsuae.com

Transcript of UK PERKINS APS P1250 kVA - · PDF fileUK PERKINS APS P1250 kVA GENERATOR FEATURES ENGINE DATA...

Page 1: UK PERKINS APS P1250 kVA - · PDF fileUK PERKINS APS P1250 kVA GENERATOR FEATURES ENGINE DATA ALTERNATOR DATA ... K Perkins, 4012-46TWG2A 0 V Litres Manufacturer Number of Phase Power

UK PERKINSAPS P1250 kVA

GENERATOR FEATURES

ENGINE DATA ALTERNATOR DATA

Manufacturer/Model

Cylinder Arrangement

Displacement

Bore And Stroke

Compression Ratio

Rated Rpm

Gross Bhp @ Prime Power

Gross Bhp @ S.By Power

Governor Type

UK Perkins, 4012-46TWG2A

012- 60 V

45.842 Litres

160 x 190 mm

13.6 : 1

1500

1492

1641

Manufacturer

Number of Phase

Power factor

Number of pole

Insulation

Temperature Rise

Total Harmonics (TGH/THC)

Exciter Type

Number Of Bearing

Leroy somer EU

3

0.8

4

Class H

Class F

< 2% (AT NO LOAD)

Shunt

One

POWER

FEATURES

Prime Power – 400/230V @ 50 Hz:1002 kW / 1253 kVA Stand by Power- 400/230V @ 50 Hz: 1108 kW / 1385 kVA

Ÿ Engine (UK Perkins 4012-46TWG2A)Ÿ 24v Charge alternator Ÿ Governor: Mechanical Ÿ Alternator (Mecc alte UK / Leroy somer TAL) Ÿ Single bearing alternator IP 23,insulation class H Ÿ Radiator 50° C (122 F) Ÿ Skid and vibration isolators Ÿ Dry type air filter Ÿ Main line circuit breaker Ÿ 24v Battery , Rack and Cable Ÿ Industrial silencer Ÿ User manual

OPTIONAL ITEMSEngine & Radiator

Ÿ Heat shield protection exhaustŸ Oil drain extensionŸ Lube oil drain pumpŸ Stone Protection guardŸ Battery chargerŸ Engine Block heaterŸ Battery Isolator

Fuel SystemŸ 12 or 24 Hours day tankŸ Bulk fuel tank connections Ÿ Fuel / Water separator filter (Racor)

AlternatorŸ Anti-Condensation HeaterŸ Alternator Dust FiltersŸ PMG excitationŸ Single phase

ExhaustŸ Residential, Critical SilencerŸ Flexible exhaust connection

EnclosureŸ EM-1,5 Ÿ 85 dBA @ 1m Ÿ Dimension mm (L x W x H) – 12192 x 2438 x 2895

Control PanelŸ Deep sea Electronics

* For more technical information, please refer to the website below.

RPP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. A 10% overload capability is available for a period of 1 hour within 12hour period of operation, in accordance with ISO 3046-1. ESP: The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed

Picture shown above is only for illustration purpose, May contain optional item. In Line with Our Policy of Continuous Development, We reserve The Right to Change Specification without Notice