TUX-D-2 Upflow/Horizontal Left Downflow/Horizontal … · Upflow/Horizontal Left...
-
Upload
truongdung -
Category
Documents
-
view
258 -
download
8
Transcript of TUX-D-2 Upflow/Horizontal Left Downflow/Horizontal … · Upflow/Horizontal Left...
Upflow/Horizontal LeftDownflow/Horizontal RightCondensing, Direct VentGas-Fired Furnace
XR 90TUX040,060,080,100,120CTDX040,060,080,100,120C
Single-Stage Fan AssistedCombustion System
PUB. NO. 22-1674-04-0803 (EN)
TUX-D-2
© 2003 American Standard Inc. All Rights Reserved 2 22-1674-04-0803 (EN)
GeneralFeatures
NATURAL GAS MODELSCentral Heating furnace designs arecertified by the American Gas Associationfor both natural and L.P. gas. Limitsetting and rating data were establishedand approved under standard ratingconditions using American NationalStandards Institute standards.
SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the system isin the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.
QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positive dis-charge of gas fumes to the outside.
BURNERSMultiport Inshot burners will give years ofquiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.
INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also contains connec-tion points for E.A.C./humidifier.
AIR DELIVERYThe four speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.
STYLINGHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat ex-changer section of the cabinet is com-pletely lined with foil faced fiberglassinsulation. This results in quiet andefficient operation due to the excellentacoustical and insulating qualities offiberglass. Built-in bottom pan andalternate bottom, left or right side returnair connection provision.
FEATURES ANDGENERAL OPERATIONThe XR 90 High Efficiency Gas Furnacesemploy a Silicon Carbide Hot SurfaceIgnition system, which eliminates thewaste of a constant burning pilot. Theintegrated system control lights the mainburners upon a demand for heat from theroom thermostat. Complete front serviceaccess.
a. Low energy power venter
b. Vent proving pressure switch.
22-1674-04-0803 (EN) 3
Contents
General Features 2
Features and Benefits 3XR 90 Standard Equipment 3XR 90 Optional Equipment 4
General Data 5TUX040C924D 5TUX060C936D 5TUX080C942D 5TUX080C960D 5TUX100C948D 6TUX100C960D 6TUX120C960D 6TDX040C924D 7TDX060C936D 7TDX080C942D 7TDX100C948D 8TDX120C960D 8
Performance Data 9
Electrical Data 11
Field Wiring 13
Twinning Field Wiring 14
Dimensions 15
Featuresand Benefits
XR 90 Standard Equipment• Power supply 115/1/60
• Convertible to horizontal left
• Type 29-4C™ stainless steel second-ary heat exchanger
• Inner blower doors
• Direct drive, 4-speed motors
• Silicon Nitride igniter with adaptiveheat up
• Accessory hook-up capability –Hum and EAC
• Quiet induced draft blower
• Blower door safety switch
• Dual solenoid combination gas valve ®ulator
• Cleanable high velocity filters
• PVC venting – 1 or 2 pipe vent option
• Left/right gas connection
• Selectable cooling fan off delayeliminates need for BAY24X045 timedelay relay
• Single wire twinning
• Integrated solid state control with self-diagnostics
• 24 volt fuse
• Manual reset burner box limit
• Lifetime limited primary heatexchanger or secondary heatexchanger warranty to originalowner (Residential use)
• 5 Year limited parts warranty
• Optional extended warranties
4 22-1674-04-0803 (EN)
Features andBenefits
XR 90 Optional EquipmentThermostat, Mechanical Heating Only Without Fan Switch ......................................................................................BAYSTAT388 [ ]Thermostat, Mechanical Heating Only With Fan Switch ...........................................................................................BAYSTAT303 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................................................ AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ..............................................................TAYSTAT300C [ ]Propane Conversion Kit ........................................................................................................................................ BAYLPKT210B [ ]Propane Conversion Kit (stainless steel burners) .................................................................................................. BAYLPSS210B [ ]Wall Mount Flange – 3" .............................................................................................................................................. BAY96X147 [ ]Wall Mount Flange – 2" .............................................................................................................................................. BAY96X148 [ ]Downflow Subbase ................................................................................................................................................. BAYBASE205 [ ]Filter Access Door Kit .............................................................................................................................................. BAYFLTR206 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFE175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ........................................................... TFE210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ..................................................... TFE245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ....................................................... TFM175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ............................................................. TFM210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ....................................................... TFM245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................................ TFP175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ...................................................... TFP210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................................ TFP245A9FR0 [ ]Side Filter Rack ...................................................................................................................................................... BAYFLTR200 [ ]Coil Enclosure (17-1/2" Wide Cabinets) ................................................................................................................ BAYCLE1700C [ ]Coil Enclosure (21" Wide Cabinets) ...................................................................................................................... BAYCLE2100C [ ]Coil Enclosure (24-1/2" Wide Cabinets) ................................................................................................................ BAYCLE2400C [ ]High Altitude Pressure Switch Kit TUX040,100C960D; TDX040C ........................................................................... BAYHALT230 [ ]High Altitude Pressure Switch Kit TUX060C ............................................................................................................ BAYHALT231 [ ]High Altitude Pressure Switch Kit TUX080C ............................................................................................................ BAYHALT232 [ ]High Altitude Pressure Switch Kit TUX100C948D,120C; TDX080,120C ................................................................. BAYHALT233 [ ]High Altitude Pressure Switch Kit TDX100C ............................................................................................................ BAYHALT234 [ ]High Altitude Pressure Switch Kit TDX060C ............................................................................................................ BAYHALT241 [ ]Concentric Vent Kit ...............................................................................................................................................BAYVENT100A [ ]Sidewall Vent Termination Kit .............................................................................................................................. BAYVENT200B [ ]Manufactured/Mobile Home Kit ............................................................................................................................ BAYMFGH100A [ ]
22-1674-04-0803 (EN) 5
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
GeneralData
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feetabove sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TUX080C960D
Upflow / Horizontal
80,00074,00092.0
30 - 60
DIRECT10 x 11
14
See Fan Performance Table3/4
1075115/1/60
CentrifugalDirect - 1
1/25 - 3200115/1/60
1.35
YesHigh Velocity
1 - 20x25 - 1in.
2 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot4
115/1/6013.520
1/2
H x W x D41-3/4 x 23 x 30-1/2
171 / 160
TUX040C924D
Upflow / Horizontal
40,00038,00092.0
30 - 60
DIRECT9 x 7
14
See Fan Performance Table1/5
1075115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.0
YesHigh Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot2
115/1/604.815
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
139 / 129
TUX060C936D
Upflow / Horizontal
60,00056,00092.0
30 - 60
DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.0
YesHigh Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot3
115/1/608.415
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
150 / 140
TUX080C942D
Upflow / Horizontal
80,00074,00092.0
35 - 65
DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/24 - 3200115/1/60
1.35
YesHigh Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot4
115/1/609.515
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
158 / 148
6 22-1674-04-0803 (EN)
GeneralData
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feetabove sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TUX100C948D
Upflow / Horizontal
100,00093,00092.0
35 - 65
DIRECT10 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71
YesHigh Velocity
1 - 20x25 - 1in.
2 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot5
115/1/6012.515
1/2
H x W x D41-3/4 x 23 x 30-1/2
171 / 160
TUX120C960D
Upflow / Horizontal
120,000113,000
92.040 - 70
DIRECT11 x 10
14
See Fan Performance Table3/4
1100115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71
YesHigh Velocity
1 - 24x25 - 1in.
3 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot6
115/1/6012.915
1/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
205 / 193
TUX100C960D
Upflow / Horizontal
100,00093,00092.0
35 - 65
DIRECT11 x 10
14
See Fan Performance Table3/4
1100115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71
YesHigh Velocity
1 - 24x25 - 1in.
2 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot5
115/1/6012.915
1/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
197 / 185
22-1674-04-0803 (EN) 7
GeneralData
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feetabove sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TDX040C924D
Downflow / Horizontal
40,00038,00091.0
30 - 60
DIRECT10 x 7
14
See Fan Performance Table1/5
1080115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.14
YesHigh Velocity
2 - 14x20 - 1in.
2 Round
Aluminized Steel - Type I
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot2
115/1/604.815
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
145 / 135
TDX060C936D
Downflow / Horizontal
60,00056,00091.0
30 - 60
DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.0
YesHigh Velocity
2 - 14x20 - 1in.
2 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot3
115/1/609.215
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
155 / 145
TDX080C942D
Downflow / Horizontal
80,00074,00091.0
35 - 65
DIRECT11 x 8
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/25 - 3200115/1/60
1.35
YesHigh Velocity
2 - 14x20 - 1in.
2 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot4
115/1/6011.415
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
168 / 158
8 22-1674-04-0803 (EN)
GeneralData
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feetabove sea level.
3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TDX120C960D
Downflow / Horizontal
120,000110,000
91.040 - 70
DIRECT11 x 10
14
See Fan Performance Table3/4
1075115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71
YesHigh Velocity
2 - 16x20 - 1in.
3 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot6
115/1/6013.920
1/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
206 / 196
TDX100C948D
Downflow / Horizontal
100,00094,00091.0
35 - 65
DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71
YesHigh Velocity
2 - 16x20 - 1in.
2 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot5
115/1/6013.620
1/2
H x W x D41-3/4 x 23 x 30-1/2
185 / 175
22-1674-04-0803 (EN) 9
PerformanceData
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90
TUX040C924D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1043940837729
992895798694
930841752657
885791705600
812726649545
740650560478
647559438376
518420305220
457390279178
TUX060C936D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
139412501102957
135912321092944
131412021069922
126011601034891
11961106986853
11221040925806
1038962852750
945873766686
853771668614
TUX080C942D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
174813751178859
168313671167863
161513471147856
154413141119839
147012681082811
139312101036772
13141139982723
12321056919663
1147960847592
TUX080C960D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2304198016681375
2262196316541372
2219194616401368
2170191916261361
2121189216111354
2048185315871330
1975181415621305
1893175115111267
1811168714601229
TUX100C948D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2054193217621558
1980187517201546
1906181816771533
1826174616151477
1746167315521421
1649157714631350
1551148113731278
1428137112661175
1305126011581071
TUX100C960D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2411210817721480
2358208317591477
2304205817451474
2235200717231458
2165195617001441
2083189316571414
2001182916131386
1915175415441327
1828167914751268
TUX120C960D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2454210517471445
2406209217421447
2358207817361449
2310204517201440
2261201217031430
2184195016771400
2106188716511369
2017182615931325
1928176515351280
From D330656 Sh.1 Rev. 12
CFM VS. TEMPERATURE RISE
MODELCubic Feet Per Minute (CFM)
600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200
TUX040C924 56 48 42 37 33
TUX060C936 56 50 45 42 39 36
TUX080C942 61 56 51 48 44 42
TUX080C960 61 56 51 48 44 42 39 37 35 33 32 30
TUX100C948 64 60 56 52 49 46 44 42
TUX100C960 64 60 56 52 49 46 44 42 40 38
TUX120C960 63 59 56 53 50 48 46
From C340405 Sh. 1 Rev. 5
NOTE: See page 11 for factory heat & cool speed tap settings
10 22-1674-04-0803 (EN)
PerformanceData
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90
TDX040C924D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
998856753647
965832728617
922797694581
870751650538
807695596490
735628533435
653550460375
561462378308
459363286235
TDX060C936D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
148713421181877
142512911147863
136212401113849
128611821061820
120911241009791
11251047943739
1040989877686
935869779612
830769681537
TDX080C942D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1547148713881263
1498143613481234
1445138213021196
1386132512491150
1323126511911095
1254120211261032
118011371056960
11011069979879
1016998896790
TDX100C948D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1892177916301444
1827172615871416
1762167215441388
1688160514851348
1614153814261308
1531146013621246
1448138112971184
1354129112081108
1260120011191032
TDX120C960D
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2213205717651468
2138200017331452
2062194317001435
2001188316521409
1939182216031382
1863175215521336
1786168115001290
1706159514241225
1625150813471159
From D330710 Rev.10
CFM VS. TEMPERATURE RISE
MODELCubic Feet Per Minute (CFM)
600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
TDX040C924D 56 48 42 37 34
TDX060C936D 63 56 51 46 42 39 36 34
TDX080C942D 61 56 52 48 45 42 40 37 35
TDX100C948D 65 60 56 53 50 47 44 42 40 38 37 35
TDX120C960D 67 63 59 56 53 51 48 46 44 42
From C330767 Sh. 1 Rev. 3
22-1674-04-0803 (EN) 11
ElectricalData
From Dwg. D341852 Rev. 1
12 22-1674-04-0803 (EN)
ElectricalData
From Dwg. D341854 Rev. 1
22-1674-04-0803 (EN) 13
FieldWiring
OUTDOOR UNIT (NO TRANSFORMER)
SEE NOTE 6
From Dwg. B340388 Rev. 2
SEE NOTE 8
FURNACE
B/CB/C
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING, 1 STAGE COOLING
USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT(OUTDOOR SECTION WITHOUT TRANSFORMER)
SEE NOTE 6
From Dwg. B341437 Rev. 1
FURNACE
TWIN
SEE NOTE 7
B/CB/C TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING
USING A 1 STAGE HEATING THERMOSTATNO COOLING
14 22-1674-04-0803 (EN)
TwinningField Wiring
TWIN TWIN
R1 R1
TWINNING CONNECTION DIAGRAMFOR TWINNING 1 STAGE FURNACES WITH
SINGLE WIRE TWINNING FEATURE1 STAGE HEATING ONLY THERMOSTAT1 STAGE HEAT
ONLYTHERMOSTAT
(WITH FAN SWITCH) FURNACE NO. 1 FURNACE NO. 2
BLOWER OPERATION OF UNIT NO. 2 IS SYNCRONIZEDWITH UNIT NO. 1 VIA SIGNALS
FROM TWIN CONNECTION.
SEE NOTE 4
SEE NOTE 3
ISOLATION RELAY(FIELD SUPPLIED)
SEE NOTE 4
ISOLATION RELAYSEE NOTE 4
B/CB/CB/C
From Dwg. 21B341422 Rev. 3
TWIN TWIN
R1
R1
TWINNING CONNECTION DIAGRAMFOR TWINNING 1 STAGE FURNACES WITH
SINGLE WIRE TWINNING FEATURE1 STAGE HEAT / 1 STAGE COOL THERMOSTAT
1 STAGEHEATING / COOLING
THERMOSTAT FURNACE NO. 1 FURNACE NO. 2
BLOWER OPERATION OF UNIT NO. 2 IS SYNCRONIZEDWITH UNIT NO. 1 VIA SIGNALS
FROM TWIN CONNECTION.
SEE NOTE 4
SEE NOTE 5
ISOLATION RELAY(FIELD SUPPLIED)
SEE NOTE 4
ISOLATION RELAYSEE NOTE 4
OUTDOOR UNIT(NO TRANSFORMER)
OUTDOOR UNIT(WITH TRANSFORMER)
RC
ISOLATION RELAY(FIELD SUPPLIED)
SEE NOTE 3
B/CB/CB/C
From Dwg. 21B341423 Rev. 2
22-1674-04-0803 (EN) 15
From Dwg. 21C340574 Rev. 12
TUX-C-D Outline Drawing(ALL DIMENSIONS ARE IN INCHES)
Dimensions
MODEL A B C D E F
TUX040C924TUX060C936TUX080C942
17-1/2" 2-1/4" 16-1/4" 16" 7-1/2" 2"
TUX080C960TUX100C948
21" 2-1/2" 19-3/4" 19-1/2" 9" 3"
TUX100C960TUX120C960
24-1/2" 2-15/16" 23-1/4" 23" 10" 3"
P.I.
Trane has a policy of continuous product and product data improvement and it reserves the right to changedesign and specifications without notice.
TraneA business ofAmerican Standard Companieswww.trane.com
From Dwg. 21C341885 Rev. 0
TDX-C-D Outline Drawing(ALL DIMENSIONS ARE IN INCHES)
Dimensions
Literature Order Number TUX-D-2
File Number PL-UN-FURN-TUX-D-2 08/03
Supersedes TUX-D-1 06/02
Stocking Location PI Louisville